SurgHorizon: Long-Horizon Surgical World Modeling with Plausible Instrument-Tissue Dynamics

Wentao Pan, Wuyang Li, Shengyuan Liu, Xinyu Liu, Hengyu Liu, Yixuan Yuan

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

TL;DR. SurgHorizon proposes deformation consistency regularization and drift adaptation training to enable stable, long-horizon surgical world modelig.

Abstract. Scaling robot policy learning for autonomous surgery is challenging, as expert demonstrations are expensive and in vivo exploration poses substantial safety risks. Surgical world models address this by generating realistic, action-conditioned future frames from an initial observation, but existing methods exhibit two persistent failure modes: spatial interaction incoherence, where visible instrument contact fails to induce spatially consistent tissue deformation, and temporal fidelity collapse, where prediction errors compound across autoregressive rollouts and progressively corrupt visual quality. We present SurgHorizon, a surgical world model that mitigates both failures through two training recipes. Deformation Consistency Regularization extracts scene-point trajectories from training videos and enforces cross-frame coherence through latent contrastive learning, promoting plausible instrument-tissue dynamics. Drift Adaptation Training mitigates long-horizon drift by perturbing conditioning frames with online prediction residuals and photometric augmentations calibrated to long-horizon drift statistics, sustaining visual fidelity over extended rollouts. To enable rigorous evaluation, we further introduce SurgWorld-Bench, featuring diverse procedure types, long-range rollouts, and decoupled metrics for instrument-motion accuracy and tissue-response fidelity. Extensive experiments show that SurgHorizon consistently outperforms state-of-the-art methods across visual quality, temporal consistency, and interaction fidelity, with gains widening as the prediction horizon grows.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
16 Apr 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)forumreviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:46 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

This paper introduces SurgVista, an action-conditioned "surgical world model" built on the Wan2.1-1.3B video diffusion model, designed to synthesize realistic endoscopic video frames. The work targets two failure modes in surgical video generation: (1) spatial interaction incoherence and (2) temporal fidelity collapse. It additionally introduces SurgWorld-Bench based on 3 public video datasets across different surgery types. The current state of the paper is that work is needed to address the main weaknesses.

Strengths: All reviewers agree that the problem is well-motivated, and proposes methods to address them accordingly. Reviewers also appreciate the introduction of the benchmark.

Weaknesses (if addressed, will be part of the discussions with reviewers that may affect the meta-review): The authors should aim to address all weaknesses pointed out by reviewers. Some that are notable: (1) unclear link between DCR loss design and deformation consistency as pointed out by reviewer zMkW, (2) CoTracker is heavily relied on for metrics and method but it might not be reliable -- this could be a major concern since a lot is based on this model, (3) formulation of the Average Jaccard metric brought up by reviewer nezC, (4) evaluation concerns regarding cases like "video has an instrument but no interaction with tissue" or "blur, smoke, or lens contamination", the latter of which are omitted during data curation, (5) small size of the long horizon evaluation clips brought up by multiple reviewers, (6) significance test of contribution of each component as brought up by reviewer TqFz

Final justification

The authors provided a thorough rebuttal that addressed the reviewers' primary concerns. However, paper acceptance comes with conditions for the camera-ready version: (1) The authors promised corrections & updates to the camera ready version (e.g. corrections to equations, no contact and other imaging artifacts) (2) The human study on the manual annotation regarding CoTracker's reliability must be included in the final paper or appendix. Please note that because this empirical validation was introduced during the rebuttal, it could not undergo a full peer-review cycle. (3) I have reservations about the use of the term "surgical world model", which is not well-defined and may overclaim the scope of the method. In line with your rebuttal, please ensure the final text clarifies this definition so as not to overclaim the model's capabilities regarding physical simulation. It might be better to remove it and change it to video generation, which is what the model actually does.

Area Chair b6c1 · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

This paper introduces SurgVista, an action-conditioned "surgical world model" built on the Wan2.1-1.3B video diffusion model, designed to synthesize realistic endoscopic video frames. The work targets two failure modes in surgical video generation: (1) spatial interaction incoherence and (2) temporal fidelity collapse. It additionally introduces SurgWorld-Bench based on 3 public video datasets across different surgery types. The current state of the paper is that work is needed to address the main weaknesses.

Strengths: All reviewers agree that the problem is well-motivated, and proposes methods to address them accordingly. Reviewers also appreciate the introduction of the benchmark.

Weaknesses (if addressed, will be part of the discussions with reviewers that may affect the meta-review): The authors should aim to address all weaknesses pointed out by reviewers. Some that are notable: (1) unclear link between DCR loss design and deformation consistency as pointed out by reviewer zMkW, (2) CoTracker is heavily relied on for metrics and method but it might not be reliable -- this could be a major concern since a lot is based on this model, (3) formulation of the Average Jaccard metric brought up by reviewer nezC, (4) evaluation concerns regarding cases like "video has an instrument but no interaction with tissue" or "blur, smoke, or lens contamination", the latter of which are omitted during data curation, (5) small size of the long horizon evaluation clips brought up by multiple reviewers, (6) significance test of contribution of each component as brought up by reviewer TqFz

Final justification

The authors provided a thorough rebuttal that addressed the reviewers' primary concerns. However, paper acceptance comes with conditions for the camera-ready version: (1) The authors promised corrections & updates to the camera ready version (e.g. corrections to equations, no contact and other imaging artifacts) (2) The human study on the manual annotation regarding CoTracker's reliability must be included in the final paper or appendix. Please note that because this empirical validation was introduced during the rebuttal, it could not undergo a full peer-review cycle. (3) I have reservations about the use of the term "surgical world model", which is not well-defined and may overclaim the scope of the method. In line with your rebuttal, please ensure the final text clarifies this definition so as not to overclaim the model's capabilities regarding physical simulation. It might be better to remove it and change it to video generation, which is what the model actually does.

1 comment
Authors · CommentOpenReview ↗

Dear Area Chair,

We are encouraged that reviewers recognized SurgVista as a well-motivated, novel, and valuable contribution. To address the concerns highlighted in the metareview, we summarize our main rebuttal additions:

DCR and deformation consistency: Clarified that tissue trajectories capture deformation and that DCR promotes temporal consistency by preserving correspondence across frames. The region-level ablation of DCR supports the intended link. Please see our response to Reviewer zMkW.

Model reliability: Added manual validation against human annotations and sensitivity tests with trajectory and mask perturbations. CoTracker shows mean/median endpoint errors of 1.35/0.58 pixels, while evaluation using manual annotations preserves the method ranking. Please see our response to Reviewer nezC.

Average Jaccard formulation: Corrected Eq. 12 to match the official TAP-Vid formulation. All results use its official implementation and are unaffected. Please see our response to Reviewer nezC.

No-contact cases and imaging artifacts: Added evaluations on no-contact and artifact-affected clips. SurgVista continues to outperform Wan2.1-Control in both settings. Please see our response to Reviewer nezC.

Long-horizon evaluation size: Expanded the evaluation to 50 clips and added significance tests. SurgVista consistently outperforms Wan2.1-Control in both sets. Please see our responses to Reviewers TqFz and zMkW.

Component significance: Added repeated runs and significance tests. DCR yields significant improvements on most metrics. Please see our response to Reviewers TqFz.

Additional analyses assess hyperparameter sensitivity, de novo synthesis, scope and other implementation details.

Best,
Authors

Reviewer zMkWOpenReview ↗
Rating
5/6
Confidence
4/5
Quality
3/4
Clarity
2/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The paper propose SurgVista, a  surgical world model to address two challenges: (i) Spatial Interaction Incoherence, where tissues incorrectly responses to instrument contact; (ii) Temporal Fidelity Collapse, where visual quality degrades over long-horizon. The work propose two training strategies: (i) Deformation Consistency Regularization to enforces cross-frame coherence along scene-point trajectories and suppress incoherent instrument-tissue dynamics, and Drift Adaptation Training to mitigates long-horizon drift by perturbing training conditions with online prediction residuals and photometric degradations. This work further propose  SurgWorld-Bench, a benchmark with decoupled metrics for instrument-motion accuracy and tissue-response fidelity. Experiment on the propsed SurgWorld-Bench shows improvement from existing methods across different metrics.

Strengths and weaknesses

Strengths The paper identifies two important failure modes and proposed methods to address them accordingly. This is a clear and well-motivated problem. Also, the proposed DAT approach for training is an elegant and novel formulation. Finally, the introduction of a new benchmark with decoupled metrics for instrument-motion accuracy and tissue-response fidelity, is valuable to the community for future work evaluation.

Weaknesses:

The main weakness is around clarity and specifically the link between DCR loss design and deformation consistency. The proposed DCR enforces consistency of latent representations with similar trajectory through InfoNCE, but not the deformation itself. It is unclear how enforcing consistency of latent representations through trajectories can improve deformation consistency. Following, the connection between the supervision signal (keypoint trajectories) and deformable tissues is unclear. DCR uses keypoint trajectories as supervision signal for cross-frame coherence, while the trajectories shows the motion of the rigid instruments, the connection of the trajectories to instrument-tissue dynamics is unclear (i.e how does it links to the deformation correctness). This is a major point.

In addition, the proposed dataset only contains 21 long horizon evaluation clips, which may be insufficient to draw a conclusion of improvement statistically.

Questions
  • Can you quantitatively demonstrate how enforcing consistency of latent representations through trajectories improves deformation consistency ?

  • Can you elaborate on the connection between the keypoint trajectories to instrument-tissue dynamics ?

  • Can you showcase that the stated improved is statistically important. In other term can you show that your model makes consistently better predictions than the SOTA ?

Limitations

Yes the major limitations of the proposed model are discussed.

Final justification

The authors have completed a thorough rebuttal with detailed responses that satisfy my comments. Final recommendation is for accept.

Formatting concerns

N/A

2 comments
Authors · RebuttalOpenReview ↗
Rebuttal

Thank you for recognizing the novelty of DAT, and the value of SurgWorld-Bench, as well as for the constructive feedback. Below, we provide a point by point response.

[W1] How DCR improves deformation consistency.

DCR promotes deformation consistency by preserving the correspondence of the same scene point as it moves across frames. Its trajectory records the observed displacement, and DCR keeps the features sampled along this path consistent. The positive pairs therefore represent the same tracked point across frames, rather than points with similar trajectories. Together with flow matching, this reduces correspondence drift and encourages coherent tissue motion over time.

[Q1] Quantitative evidence.

To quantify whether DCR improves deformation consistency, we compare tissue-point trajectories in generated and ground-truth videos. These trajectories provide sparse measurements of tissue displacement over time, so their agreement reflects how closely the generated deformation follows the reference. We quantify this agreement using Tis. AJ and Tissue δavgvis\delta_{\mathrm{avg}}^{\mathrm{vis}}. As shown below, we conduct a controlled ablation by varying only the DCR supervision region. Compared with no DCR, tissue-only supervision improves Tis. AJ and δavgvis\delta_{\mathrm{avg}}^{\mathrm{vis}} by 5.16 and 5.47 points, while full-frame supervision achieves gains of 5.61 and 5.86 points. Instrument-only supervision yields smaller tissue gains of 2.32 and 2.86 points. These results show that DCR improves reference-aligned tissue deformation, with larger gains when tissue trajectories are directly supervised.

DCR supervision Ins. AJ ↑ Instrument δavgvis\delta_{\mathrm{avg}}^{\mathrm{vis}} ↑ Tis. AJ ↑ Tissue δavgvis\delta_{\mathrm{avg}}^{\mathrm{vis}} ↑
Without DCR 40.42 53.13 36.07 49.43
Instrument points only 44.91 57.62 38.39 52.29
Tissue points only 44.42 57.21 41.23 54.90
Full frame 45.76 58.43 41.68 55.29

[Q2] Connection between trajectories and instrument–tissue dynamics.

Instrument trajectories serve as the action condition, whereas DCR independently samples up to 64 scene-point trajectories from both instrument and tissue regions. These trajectories capture the observed motion of both instruments and tissues, including contact-induced deformation when present. The model learns the instrument–tissue interaction through flow matching, while DCR promotes coherent motion by maintaining feature consistency along the corresponding trajectories.

[W2 and Q3] Long horizon sample size and statistical significance.

For the long-horizon evaluation, we conduct clip-level paired comparisons between SurgVista and the state-of-the-art baseline Wan2.1-Control. We report the mean and standard deviation, along with the mean paired difference and its 95% confidence interval, and assess statistical significance using a two-sided paired t-test. On the original set of 21 clips, SurgVista significantly outperforms Wan2.1-Control across all four metrics.

21 clips (long) Ins. AJ ↑ Ins. δavgvis\delta_{\mathrm{avg}}^{\mathrm{vis}} ↑ Tis. AJ ↑ Tis. δavgvis\delta_{\mathrm{avg}}^{\mathrm{vis}} ↑
Wan2.1-Control 18.92 ± 5.01 28.30 ± 6.41 19.91 ± 10.98 31.90 ± 12.98
SurgVista 27.13 ± 6.76* 39.61 ± 7.21* 24.15 ± 11.03* 38.19 ± 12.23*
Mean paired Δ\Delta [95% CI] +8.21 [+6.09, +10.33] +11.31 [+9.39, +13.24] +4.24 [+1.89, +6.59] +6.28 [+3.24, +9.33]

Note: * indicates p < 0.05 from a two-sided paired t-test.

To further assess robustness, we collected 29 additional clips, expanding the evaluation set from 21 to 50 clips. SurgVista continues to significantly outperform Wan2.1-Control across all four metrics.

50 clips (long) Ins. AJ ↑ Ins. δavgvis\delta_{\mathrm{avg}}^{\mathrm{vis}} ↑ Tis. AJ ↑ Tis. δavgvis\delta_{\mathrm{avg}}^{\mathrm{vis}} ↑
Wan2.1-Control 19.26 ± 6.49 30.30 ± 9.29 19.15 ± 10.46 32.23 ± 12.21
SurgVista 27.42 ± 7.42* 41.42 ± 8.50* 22.96 ± 11.42* 38.39 ± 12.26*
Mean paired Δ\Delta [95% CI] +8.15 [+7.14, +9.17] +11.13 [+9.94, +12.31] +3.81 [+2.63, +4.98] +6.16 [+4.58, +7.74]

Note: * indicates p < 0.05 from a two-sided paired t-test.

Authors · CommentOpenReview ↗

Dear Reviewer zMkW,

Thank you again for your thoughtful feedback. As the discussion period is nearing its end, we wanted to ensure that our response has adequately addressed your concerns. Please let us know if there are any additional points or feedback you would like us to consider.

We greatly appreciate your time and effort in reviewing our paper.

Reviewer nezCOpenReview ↗
Rating
4/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This work attempts to address two limitations in synthesizing action-conditioned future frames in surgical videos - instrument interaction does not result in coherent tissue deformation, and across time, the synthesis loses fidelity. This work uses regularization with scene-point trajectories and perturbations of conditioning frames and calibrating photometric augmentation. Contributions include a model trained to address the two limitations and a dataset.

Strengths and weaknesses

Strengths:

  1. Focus on two specific problems in synthesizing surgery videos.
  2. Specific solutions to the two problems.
  3. Using instrument trajectories as a conditioning signal, and its error to inform a loss.
  4. An interesting approach to a relevant problem.

Weaknesses:

  1. Some of the newly proposed metrics and methods are dependent upon other model predictions, e.g., CoTracker for instrument control accuracy and tissue feedback fidelity. The error in the model predictions are not propagated to the metrics.

  2. I don't see the need for an Average Jaccard (eq 12). The count of pixels is a sufficient metric that can be aggregated in different ways, some of which are statistically appropriate and some are not. For example, there is no clear principled reasoning for omitting the TN pixels. On the other hand, simply using the confusion matrix for each frame allows statistically principled estimates of position accuracy and occlusion prediction. The simple aggregation adopted in equations 12 and 13 make the estimates over-optimistic because they ignore correlations within and between frames in a video. The multilievel aggregation as described makes it impractical to compute a measure of variance for the estimand.

  3. What if a video has an instrument but no interaction with tissue? We can see this in practice.

  4. Unclear how this method accounts for/uses/ignores differences in how the same tissue behaves with different instruments.

  5. How sensitive is this method to segments with blur, smoke, or lens contamination? Curious why these segments are omitted during data curation.

  6. Error in synthesis at one point means that the autoregressive synthesis propagates it through subsequent points in time. Would it not be useful to do a de novo synthesis and augment it with autoregressive propagation?

  7. Not clear what contribution this paper makes to a "benchmark" given that the datasets are publicly available and have not been augmented by this work.

Questions
  1. What is a surgical world model? The claim in footnote on first page - it is not clear why interaction between entitles in the world do not need to have precise instrument control. It is not a condition unique to surgery. Not a technical issue, more for writing clarity and coherence.
  2. Not clear what contribution this paper makes to a "benchmark" given that the datasets are publicly available and have not been augmented by this work. What is this contribution?
  3. Some of the newly proposed metrics and methods are dependent upon other model predictions, e.g., CoTracker for instrument control accuracy and tissue feedback fidelity. The error in the model predictions are not propagated to the metrics. What is the sensitivity of this method to errors in models on which it depends, e.g., CoTracker, segmentation model, and others.
Limitations

Discussion of limitations is appropriate but at a very high-level.

Final justification

The responses seem adequate. Excluding TN from AJ is a limitation because the exclusion can result in bias in estimating AJ. Acknowledging this limitation in the metric will be appropriate. I'll stay at borderline accept.

Formatting concerns

None.

3 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We appreciate your your valuable feedback. We address each point below.

[W1&Q3] Reliability of dependency models and error propagation to the evaluation metrics.

To quantify CoTracker accuracy, we manually annotated six corresponding trajectories (3 instrument and 3 tissue) per clip on a subset of evaluation clips, using identical initial points across the reference, Wan2.1-Control, and SurgVista videos. Using the manual annotations as ground truth, CoTracker achieved an overall AJ of 86.57% and an overall δavgvis\delta_{\mathrm{avg}}^{\mathrm{vis}} of 93.24%, with mean/median endpoint errors of 1.35/0.58 pixels and a 95th-percentile error of 4.79 pixels. We then recomputed the metrics using the human-annotated trajectories on the same subset. SurgVista retained positive paired gains over Wan2.1-Control across all four metrics, while the differences between the CoTracker- and human-based gains were only 0.24, 0.25, 0.02, and 0.11 percentage points, respectively (table below). Thus, CoTracker errors have little effect on the estimated gains and do not change the comparative conclusion on the annotated subset.

Trajectory source Method Ins. AJ Ins. δavgvis\delta_{\mathrm{avg}}^{\mathrm{vis}} Tis. AJ Tis. δavgvis\delta_{\mathrm{avg}}^{\mathrm{vis}}
CoTracker Wan2.1-Control 58.12 69.95 49.77 59.58
SurgVista 64.40 75.78 54.25 64.40
Paired Δ\Delta +6.28 +5.82 +4.48 +4.81
Human annotation Wan2.1-Control 60.84 69.45 49.26 58.32
SurgVista 66.88 75.02 53.76 63.02
Paired Δ\Delta +6.04 +5.57 +4.50 +4.70

To assess sensitivity to trajectory errors, we perturb the same fraction α\alpha of trajectory identities in the reference and both methods, while independently sampling coordinate offsets within radius RR with probability pposp_{\mathrm{pos}} and visibility flips with probability pvisp_{\mathrm{vis}}. Each cell reports Wan2.1-Control / SurgVista / paired Δ\Delta [2.5th, 97.5th Monte Carlo percentiles] over 1,000 repetitions. All paired gains remain positive across the tested settings, showing that the comparison is robust to tracking errors.

To assess sensitivity to segmentation errors, we erode or dilate the predicted first frame instrument masks by 2 and 8 pixels and recompute the regional metrics. These perturbations change 1.63% to 6.46% of the grid assignments. Each cell reports Wan2.1-Control / SurgVista / paired Δ\Delta [95% paired clip bootstrap CI]. All 95% CI lower bounds are ≥+4.40\geq +4.40 points, preserving the method ranking.

Perturbation setting Ins. AJ Ins. δavgvis\delta_{\mathrm{avg}}^{\mathrm{vis}} Tis. AJ Tis. δavgvis\delta_{\mathrm{avg}}^{\mathrm{vis}}
Clean 39.34 / 45.76 / +6.42 52.08 / 58.43 / +6.35 36.19 / 41.68 / +5.50 49.51 / 55.29 / +5.78
Trajectory: Moderate (10%,50%,8,50%)(10\%,50\%,8,50\%) 36.52 / 42.35 / +5.83 [5.78, 5.87] 50.78 / 56.92 / +6.14 [6.10, 6.17] 34.05 / 39.14 / +5.10 [5.08, 5.12] 48.46 / 54.07 / +5.61 [5.59, 5.62]
Trajectory: Severe (20%,100%,16,100%)(20\%,100\%,16,100\%) 35.54 / 41.25 / +5.71 [5.64, 5.78] 48.57 / 54.44 / +5.87 [5.80, 5.93] 34.18 / 39.51 / +5.34 [5.31, 5.37] 47.50 / 53.04 / +5.54 [5.51, 5.56]
Mask: Erosion, 2 px 39.53 / 46.03 / +6.50 [5.88, 7.15] 51.97 / 58.35 / +6.38 [5.84, 6.93] 36.18 / 41.67 / +5.49 [4.40, 6.66] 49.57 / 55.35 / +5.78 [4.69, 6.95]
Mask: Erosion, 8 px 39.41 / 46.01 / +6.60 [5.87, 7.35] 51.49 / 57.97 / +6.48 [5.88, 7.07] 36.25 / 41.74 / +5.49 [4.51, 6.58] 49.72 / 55.50 / +5.78 [4.77, 6.87]
Mask: Dilation, 2 px 38.90 / 45.23 / +6.33 [5.79, 6.91] 52.18 / 58.55 / +6.36 [5.86, 6.89] 36.22 / 41.73 / +5.51 [4.43, 6.69] 49.46 / 55.24 / +5.78 [4.69, 6.96]
Mask: Dilation, 8 px 37.85 / 43.83 / +5.99 [5.50, 6.51] 52.27 / 58.49 / +6.22 [5.73, 6.76] 36.34 / 41.87 / +5.53 [4.42, 6.77] 49.35 / 55.14 / +5.79 [4.67, 6.97]

[W2] Average Jaccard formulation.

We apologize that Eq. 12 in Appendix B was misleading. As stated in the submitted manuscript, we use AJ and δavgvis\delta_{\mathrm{avg}}^{\mathrm{vis}} from TAP-Vid, and all reported results were computed using its official implementation. Therefore, this correction does not affect any reported result. For clarity, the per clip AJ is computed as

AJ=1∣Δ∣∑δ∈Δ∑i=1N∑t=1TTPδ,t(i)∑i=1N∑t=1T(TPδ,t(i)+FPδ,t(i)+FNδ,t(i)).\mathrm{AJ}=\frac{1}{|\Delta|}\sum_{\delta\in\Delta}\frac{\sum_{i=1}^{N}\sum_{t=1}^{T}\mathrm{TP}_{\delta,t}^{(i)}}{\sum_{i=1}^{N}\sum_{t=1}^{T}\left(\mathrm{TP}_{\delta,t}^{(i)}+\mathrm{FP}_{\delta,t}^{(i)}+\mathrm{FN}_{\delta,t}^{(i)}\right)}.

where Δ=1,2,4,8,16\Delta={1,2,4,8,16} denotes the distance thresholds. For each threshold, TP, FP, and FN are pooled over all trajectories and evaluated frames within a clip before computing the Jaccard ratio. AJ is then obtained by averaging across thresholds. Eq. 13 already uses the correct ratio of sums for δavgvis\delta_{\mathrm{avg}}^{\mathrm{vis}}.

We retain AJ for jointly evaluating localization and visibility. Under this formulation, TN is excluded; jointly occluded points provide no observable position correspondence and would otherwise inflate AJ. Visibility mismatches remain penalized as FP or FN. The computation yields one AJ and one δavgvis\delta_{\mathrm{avg}}^{\mathrm{vis}} value per clip, with variability and statistical uncertainty estimated across clip scores. Frames and trajectories within a clip are therefore not treated as independent observations.

[W3] Instrument present without tissue interaction.

The tissue evaluation does not assume that a visible instrument interacts with tissue. For clips without contact, the reference trajectories capture tissue and camera motion without instrument induced deformation, so the metrics reward agreement with this behavior and penalize spurious deformation. Instrument motion is evaluated independently. We further evaluated both methods on a subset of clips with visible instruments but no observable tissue contact. SurgVista outperforms Wan2.1-Control across all four metrics, indicating that it better preserves tissue motion in the absence of contact without introducing spurious deformation.

Method Ins. AJ Ins. δavgvis\delta_{\mathrm{avg}}^{\mathrm{vis}} Tis. AJ Tis. δavgvis\delta_{\mathrm{avg}}^{\mathrm{vis}}
Wan2.1-Control 39.23 53.16 41.17 52.69
SurgVista 44.36 57.21 45.95 57.29

[W4] Tissue responses to different instruments.

SurgVista conditions tissue responses on the appearance, geometry, and trajectory of each instrument. Latent Action Encoding propagates local instrument features along the specified trajectory, allowing the model to learn different tissue responses to different instruments. DCR operates within each training sequence and does not impose the same response across instruments. However, factors not observable from the initial frame and 2D trajectory, such as applied force, are not explicitly modeled. Actions with identical visual inputs and trajectories but different forces therefore remain indistinguishable, which we clarify as a limitation.

[W5] Sensitivity to blur, smoke, and lens contamination.

Only clips with severe artifacts that prevent reliable trajectory extraction are excluded from the benchmark, whereas clips with moderate blur, smoke, or lens contamination are retained. To assess robustness under these conditions, we additionally collected a short horizon subset with naturally occurring imaging artifacts. As shown below, SurgVista outperforms Wan2.1-Control across all four metrics, indicating that its improvements persist under these conditions.

Method Ins. AJ Ins. δavgvis\delta_{\mathrm{avg}}^{\mathrm{vis}} Tis. AJ Tis. δavgvis\delta_{\mathrm{avg}}^{\mathrm{vis}}
Wan2.1-Control 35.52 48.61 32.61 45.09
SurgVista 39.84 53.91 38.08 51.05

[W6] De novo and autoregressive synthesis.

De novo synthesis limits inter-segment error propagation and improves instrument control and LPIPS for both methods. For SurgVista, however, each restart discards the evolving interaction state, reducing tissue consistency and motion smoothness. This reveals a tradeoff between limiting accumulated errors and preserving interaction state. Correcting visual drift without resetting this state or accessing future reference frames remains future work.

Method Ins. AJ ↑ Ins. δavgvis\delta_{\mathrm{avg}}^{\mathrm{vis}} ↑ Tis. AJ ↑ Tis. δavgvis\delta_{\mathrm{avg}}^{\mathrm{vis}} ↑ LPIPS ↓ Motion Smoothness ↑
Wan2.1-Control 18.92 28.30 19.91 31.90 0.4219 0.99510
w. de novo 22.44 36.15 20.81 34.64 0.3675 0.99248
SurgVista 27.13 39.61 24.15 38.19 0.3712 0.99530
w. de novo 31.68 46.75 21.85 36.20 0.3494 0.99311

[W7&Q2] Benchmark contribution.

Existing evaluations mainly use short rollouts and holistic metrics that conflate instrument control with tissue response. SurgWorld-Bench establishes a standardized long horizon evaluation protocol covering rollouts of 80 and 800 frames across three surgery types. It also introduces region-specific metrics that separately evaluates instrument control and tissue response, alongside visual quality and temporal consistency. Its contribution is the curated benchmark and evaluation protocol, not new footage.

[Q1] Definition of a surgical world model.

A surgical world model predicts future surgical scene states, represented here as endoscopic video, from the current observation and planned instrument actions. The intended emphasis is not on the precision of instrument control itself, but on generating plausible localized tissue responses to instrument actions under challenging endoscopic conditions. We will revise the footnote to clarify this distinction.

Authors · CommentOpenReview ↗

Dear Reviewer nezC,

Thank you again for your thoughtful feedback. As the discussion period is nearing its end, we wanted to ensure that our response has adequately addressed your concerns. Please let us know if there are any additional points or feedback you would like us to consider.

We greatly appreciate your time and effort in reviewing our paper.

Authors · CommentOpenReview ↗

Due to a formatting issue, the equation in our previous response was not rendered correctly. We provide the correctly formatted [W2] below.

[W2] Average Jaccard formulation.

We apologize that Eq. 12 in Appendix B was misleading. As stated in the submitted manuscript, we use AJ and δavgvis\delta_{\mathrm{avg}}^{\mathrm{vis}} from TAP-Vid, and all reported results were computed using its official implementation. Therefore, this correction does not affect any reported result. For clarity, the per clip AJ is computed as

AJ=1∣Δ∣∑δ∈Δ∑i=1N∑t=1TTPδ,t(i)∑i=1N∑t=1T(TPδ,t(i)+FPδ,t(i)+FNδ,t(i)).\mathrm{AJ}=\frac{1}{|\Delta|}\sum_{\delta\in\Delta}\frac{\sum_{i=1}^{N}\sum_{t=1}^{T}\mathrm{TP}_{\delta,t}^{(i)}}{\sum_{i=1}^{N}\sum_{t=1}^{T}\left(\mathrm{TP}_{\delta,t}^{(i)}+\mathrm{FP}_{\delta,t}^{(i)}+\mathrm{FN}_{\delta,t}^{(i)}\right)}.

where Δ=1,2,4,8,16\Delta={1,2,4,8,16} denotes the distance thresholds. For each threshold, TP, FP, and FN are pooled over all trajectories and evaluated frames within a clip before computing the Jaccard ratio. AJ is then obtained by averaging across thresholds. Eq. 13 already uses the correct ratio of sums for δavgvis\delta_{\mathrm{avg}}^{\mathrm{vis}}.

We retain AJ for jointly evaluating localization and visibility. Under this formulation, TN is excluded; jointly occluded points provide no observable position correspondence and would otherwise inflate AJ. Visibility mismatches remain penalized as FP or FN. The computation yields one AJ and one δavgvis\delta_{\mathrm{avg}}^{\mathrm{vis}} value per clip, with variability and statistical uncertainty estimated across clip scores. Frames and trajectories within a clip are therefore not treated as independent observations.

Reviewer TqFzOpenReview ↗
Rating
5/6
Confidence
4/5
Quality
3/4
Clarity
4/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The authors present a surgical world model called SurgVista that predicts future endoscopic video frames. The work addresses an existing gap in the prior work which either lack realism with tissue deformability upon instrument contact (addressed as spatial interaction incoherence) or see degradation in performance over long-horizon rollouts (referred to as temporal fidelity collapse). The SurgVista model addresses these limitations by introducing deformation consistency regularization [DCR] and drift adaptation training [DAT] processes. They use Wan2.1-1.3B flow-matching video diffusion transformer (with LoRA fine tuning) as the base. DCR is essentially a latent-space InfoNCE contrastive loss over dense point-tracker trajectories. They pull the per-frame latent descriptor for each tracked point toward its own temporal prototype and push it from the prototypes of other trajectories. DAT on the other hand corrupts the conditioning frame during training using (i) online single-step prediction residual of the model and (ii) calibrated photometric augmentations to close the train/inference conditioning gap. Finally, the authors also introduce SurgWorld-Bench developed from three public datasets namely GraSP for radical prostatectomy, SurgToolLoc22 for porcine laparoscopic procedures, and CholecTrack20 for laparoscopic cholecystectomy. They have a mix of time horizons in the dataset, and separate evaluation of tracking accuracy between instrument regions and tissue regions. This work demonstrates the benefit of SurgVista across various metrics, with notable performance for long horizon scenarios.

Strengths and weaknesses

Strengths: Overall, the authors do a good job with presenting background context for each component needed to understand the proposed model, and how SurgVista bridges the gap compared to existing work.

  1. The paper provides a good amount of detail for reproducing their work, and also includes failure modes in Appendix D.
  2. The authors approach to decomposing instrument motion accuracy from tissue response fidelity is particularly a strong contribution. The use of point tracking restricted based on the region is simple but effective to achieve the type of visually coherent deformation response that is desired
  3. The use of online prediction residuals in DAT where the drift proxy is computed from the same sample under current weights is well evaluated
  4. The authors provide ablation study analysis of their drift simulation strategies, DCR trajectory count and spatial region, and the benefits of using both DCR and DAT
  5. The long horizon contributions of the paper are notable

Weakness:

  1. While the central claim of the paper stresses the importance of long-horizon evaluation, the dataset is still limited to only about 21 video clips as opposes to 111 short-horizon samples. Since this is a reasonably small size to work with, it would be helpful to have information on per-clip variability
  2. Can the authors clarify how key points are selected and ordered? Also, how many points are chosen?
  3. A suggestion for taxonomy is about the paper restating physical consistency in multiple places. The overall technical focuses on visual coherence as opposed to being consistent with actual physics/dynamics (acknowledged by authors as well). It would be helpful to note this accordingly in the writeup.
  4. Unfortunately, a notable limitation that the authors also acknowledge is the lack of significance tests. While the cost of running repeated training runs is understandable, it would be beneficial to have this at least for a subset of the ablation experiments since the contribution of each component has only small relative margins. Considering Wan2.1-Control already has quite good performance, this would be have been helpful information to review. Especially, the benefit of DCR is currently not as obvious from Table 2.
Questions
  1. How were the clips for long-horizon evaluation chosen?
  2. The method introduces several hyperparameters including photometric augmentation ranges, pprobe,paug,pcleanp_{\mathrm{probe}}, p_{\mathrm{aug}}, p_{\mathrm{clean}}, and λDCR\lambda_{\mathrm{DCR}} but the paper does not report sensitivity analyses for them. How robust are the results to these choices?
  3. How were the photometric ranges calibrated from the rollout drift statistics in Fig. 3?
Limitations

Yes

Final justification

The authors addressed my questions directly and submitted significance tests that. They also responded to my questions on the parameter values used in their experiments by providing sufficient detail. I am good with accepting the paper.

Formatting concerns

None to report

2 comments
Authors · RebuttalOpenReview ↗
Rebuttal

Thank you for recognizing our long-horizon contribution, decoupled instrument–tissue evaluation, and comprehensive experiments, as well as for the valuable feedback. Below, we provide a point-by-point response.

[W1&Q1] Sample selection strategy and variability across clips in the long horizon evaluation.

For sample selection, we first sampled candidate sequences of 800 consecutive frames from the test videos and retained only those with a continuous endoscopic view, no scene cuts, and no prolonged inactivity. Since each sequence contains ten times as many frames as a short horizon clip, satisfying these criteria over the full duration is substantially more difficult, yielding the original benchmark set of 21 clips.

To quantify variability across clips, we report paired results comparing SurgVista with the state of the art baseline Wan2.1-Control, including the mean and standard deviation and the mean paired difference with its Student (t) 95% confidence interval for each metric. SurgVista achieved statistically significant improvements over Wan2.1-Control across all four metrics, with all p values below 0.05.

21 clips (long) Ins. AJ ↑ Ins. δavgvis\delta_{\mathrm{avg}}^{\mathrm{vis}} ↑ Tis. AJ ↑ Tis. δavgvis\delta_{\mathrm{avg}}^{\mathrm{vis}} ↑
Wan2.1-Control 18.92 ± 5.01 28.30 ± 6.41 19.91 ± 10.98 31.90 ± 12.98
SurgVista 27.13 ± 6.76* 39.61 ± 7.21* 24.15 ± 11.03* 38.19 ± 12.23*
Mean paired Δ\Delta [95% CI] +8.21 [+6.09, +10.33] +11.31 [+9.39, +13.24] +4.24 [+1.89, +6.59] +6.28 [+3.24, +9.33]

Note: * indicates p < 0.05 from a two-sided paired t-test.

To further assess robustness, we collected 29 additional clips and expanded the long horizon evaluation from 21 to 50 clips. As shown in the table below, SurgVista continued to achieve statistically significant improvements over Wan2.1-Control across all four metrics, with all p values below 0.05.

50 clips (long) Ins. AJ ↑ Ins. δavgvis\delta_{\mathrm{avg}}^{\mathrm{vis}} ↑ Tis. AJ ↑ Tis. δavgvis\delta_{\mathrm{avg}}^{\mathrm{vis}} ↑
Wan2.1-Control 19.26 ± 6.49 30.30 ± 9.29 19.15 ± 10.46 32.23 ± 12.21
SurgVista 27.42 ± 7.42* 41.42 ± 8.50* 22.96 ± 11.42* 38.39 ± 12.26*
Mean paired Δ\Delta [95% CI] +8.15 [+7.14, +9.17] +11.13 [+9.94, +12.31] +3.81 [+2.63, +4.98] +6.16 [+4.58, +7.74]

Note: * indicates p < 0.05 from a two-sided paired t-test.

[W2] Details of keypoints.

We initialize a regular 35 ×\times 35 grid on the first frame. Points inside the instrument mask are used as instrument-control keypoints, while the remaining points are treated as tissue-region points only for evaluation and are not model inputs. Points are indexed in raster-scan order, and each index identifies the trajectory initialized at the corresponding grid point without encoding semantic information. Across the 111 short-horizon clips, there are 194.46 ± 96.64 instrument points and 1030.54 ± 96.64 tissue-region points per clip, ranging from 39–488 and 737–1186, respectively.

[W3] Terminology for physical consistency.

SurgVista aims to generate plausible instrument–tissue dynamics, in which the instrument follows the specified action and the surrounding tissue exhibits visually coherent responses across space and time. To avoid implying explicit physical modeling, we will replace related terms throughout the manuscript with the more precise expression “plausible instrument–tissue dynamics”.

[W4] Significance tests and the contribution of DCR.

To quantify the contribution of DCR, we conducted two additional runs for each configuration, yielding three matched runs in total, and report mean ± std. DCR produces positive gains in both comparisons, with significant improvements in all four metrics over the Baseline and in three metrics when added to DAT.

Configuration Ins. AJ ↑ Ins. δavgvis\delta_{\mathrm{avg}}^{\mathrm{vis}} ↑ Tis. AJ ↑ Tis. δavgvis\delta_{\mathrm{avg}}^{\mathrm{vis}} ↑
Baseline 19.22 ± 0.20 28.96 ± 0.12 19.70 ± 0.32 32.06 ± 0.47
Baseline + DCR 20.43 ± 0.19* 31.04 ± 0.33* 20.75 ± 0.48* 33.29 ± 0.35*
Baseline + DAT 26.25 ± 0.27 38.56 ± 0.26 24.00 ± 0.34 37.79 ± 0.31
Full 26.91 ± 0.19* 39.38 ± 0.35* 24.54 ± 0.34 38.50 ± 0.30*

Note: * indicates p < 0.05 from a two-sided paired t-test.

[Q2] Hyperparameter sensitivity.

DCR loss weight. We evaluate λDCR∈0.005,0.01,0.02\lambda_{\mathrm{DCR}}\in{0.005,0.01,0.02} on the short horizon evaluation set. Performance remains stable across these settings, with the default value of 0.01 achieving the best results across all four metrics.

λDCR\lambda_{\mathrm{DCR}} Ins. AJ ↑ Ins. δavgvis\delta_{\mathrm{avg}}^{\mathrm{vis}} ↑ Tis. AJ ↑ Tis. δavgvis\delta_{\mathrm{avg}}^{\mathrm{vis}} ↑
0.005 44.95 57.59 41.08 54.66
0.01 45.76 58.43 41.68 55.29
0.02 45.35 58.04 40.61 53.94

DAT sampling probabilities. We evaluate three settings for (pprobe,paug,pclean)(p_{\mathrm{probe}},p_{\mathrm{aug}},p_{\mathrm{clean}}) on the long horizon evaluation set. Increasing pprobep_{\mathrm{probe}} slightly improves most metrics, whereas reducing it to 0.2 consistently degrades performance, indicating that probe sampling plays a more important role than photometric augmentation. We use (0.5,0.4,0.1) as the default to maintain sufficient probe exposure while preserving diverse drift simulation.

(pprobe,paug,pclean)(p_{\mathrm{probe}},p_{\mathrm{aug}},p_{\mathrm{clean}}) Ins. AJ ↑ Ins. δavgvis\delta_{\mathrm{avg}}^{\mathrm{vis}} ↑ Tis. AJ ↑ Tis. δavgvis\delta_{\mathrm{avg}}^{\mathrm{vis}} ↑
(0.7,0.2,0.1) 27.60 39.95 24.39 38.03
(0.5,0.4,0.1) 27.13 39.61 24.15 38.19
(0.2,0.7,0.1) 26.63 39.25 23.90 37.84

Photometric augmentation ranges. We compare weak, default, and strong augmentation settings on the long horizon evaluation set. The default setting achieves the best results on three metrics and comparable performance on the remaining metric, providing the most balanced overall performance.

Setting Brightness Contrast Sharpness Noise Ins. AJ ↑ Ins. δavgvis\delta_{\mathrm{avg}}^{\mathrm{vis}} ↑ Tis. AJ ↑ Tis. δavgvis\delta_{\mathrm{avg}}^{\mathrm{vis}} ↑
Weak [0.95,1.15] [1.0,1.5] [0.85,1.25] [0,0.01] 26.85 39.65 24.13 37.88
Default [0.8,1.5] [1.0,3.0] [0.5,2.0] [0,0.05] 27.13 39.61 24.15 38.19
Strong [0.6,2.0] [1.0,5.0] [0.2,3.0] [0,0.10] 26.36 38.51 24.01 38.07

[Q3] Calibration of photometric augmentation ranges.

We generated autoregressive rollouts of 800 frames using Wan2.1-Control on a separate calibration set. For each clip, we measured prediction to reference ratios for brightness, contrast, and sharpness, with sharpness defined by the variance of the Laplacian, together with a robust noise estimate. We averaged these statistics over the final 80 frame generation block to characterize accumulated long horizon drift and selected bounds covering the empirical drift tails.

Authors · CommentOpenReview ↗

Dear Reviewer TqFz,

Thank you again for your thoughtful feedback. As the discussion period is nearing its end, we wanted to ensure that our response has adequately addressed your concerns. Please let us know if there are any additional points or feedback you would like us to consider.

We greatly appreciate your time and effort in reviewing our paper.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.