Hyperbolic Concept Embedding Models for Interpretable Medical Image Diagnosis
Qihao Xu, Yadong Liu, Chengliang Liu, Yong Xu, Xiaoling Luo
Abstract. Although deep neural networks (DNNs) have shown strong performance in medical classification, their opaque reasoning limits interpretability and undermines the trustworthiness of clinical diagnoses. Concept bottleneck models (CBMs) introduce an intermediate concept layer, decomposing black-box prediction into an explicit reasoning path: image → concept → disease. However, concepts and their corresponding diagnostic results in medical image diagnosis are often hierarchical, inclusive, and semantically unevenly distributed. Most concept-based methods represent concepts in Euclidean space and treat them as isolated entities, hindering the modeling of their structural relationships and reducing diagnostic transparency. To address this, we introduce hyperbolic concept embedding models (HCEMs) that map medical concepts into a hyperbolic space better suited for hierarchical representation, enabling explicit modeling of complex concept relationships and their semantic associations with diseases. In these models, we regularize the hyperbolic concept embedding space using a positive–negative concept contrastive loss and a concept entailment cone loss. Furthermore, we introduce an intervention-aware regularization strategy for hyperbolic disease–concept embeddings to capture their dynamic relationships. It avoids rigid rule priors while improving diagnostic consistency and flexibility under concept interventions. Extensive experiments on four datasets demonstrate that our HCEMs achieve high accuracy in both concept and disease classification while enhancing interpretability and intervenability.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 4 reviews · OpenReview
Updated 25 Nov 2026, 03:47 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
- Reviewers agree the paper targets an important limitation of concept bottleneck models in medical diagnosis.
- They find the hyperbolic formulation promising for modeling concept hierarchy and disease-concept relations.
- The main unresolved issue is whether the concept graph encodes true clinical hierarchy or mostly dataset co-occurrence.
- Please clarify and ablate the graph construction pipeline, including GPT and clinician-validation steps.
- Please add statistical testing for the small gains over strong baselines.
- Reviewers also ask for stronger validation of interpretability, preferably against clinical guidelines or clinician assessment.
Final justification
This paper received 4 reviews, and there is a consensus that the paper should be accepted. I agree with the reviewers on the quality of the paper.
Read meta-review
Meta-review
- Reviewers agree the paper targets an important limitation of concept bottleneck models in medical diagnosis.
- They find the hyperbolic formulation promising for modeling concept hierarchy and disease-concept relations.
- The main unresolved issue is whether the concept graph encodes true clinical hierarchy or mostly dataset co-occurrence.
- Please clarify and ablate the graph construction pipeline, including GPT and clinician-validation steps.
- Please add statistical testing for the small gains over strong baselines.
- Reviewers also ask for stronger validation of interpretability, preferably against clinical guidelines or clinician assessment.
Final justification
This paper received 4 reviews, and there is a consensus that the paper should be accepted. I agree with the reviewers on the quality of the paper.
1 comment
- Rating
- 5/6
- Confidence
- 5/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 4/4
- Originality
- 4/4
- Contribution type
- use_inspired
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The HCEM model contains many obscure, field-specific jargon that creates unnecessary reading barriers for general readers. Phrases such as Lorentzian hyperbolic space, entailment cone loss and the shorthand CBM variants are highly specialized and rarely used in mainstream medical vision literature without supplementary explanations. The three proposed regularization losses are also described with overly abstract geometric terms that lack plain-language interpretations.
Strengths and weaknesses
The advantages of this paper are as follows:
-
The motivation is clear and clinically meaningful. While concept-based models improve interpretability, flat concept representations are insufficient to capture hierarchical medical knowledge, motivating the need for hierarchical concept modeling in medical diagnosis.
-
The proposed methodology is technically innovative and solid. This work is the first to introduce hyperbolic modeling into concept-based models and proposes a novel hyperbolic structural constraint for modeling concept hierarchies.
-
The overall idea and writing of the work are well presented. As an interpretable medical application study, the paper is of high quality.
-
The experimental evaluation is comprehensive, with extensive comparisons, ablation studies, and visualizations. These results effectively demonstrate the accuracy and interpretability of the proposed method.
Regarding the shortcomings of this work, the comments are as follows:
-
There are a few minor notational typos in the formulas. For example, the symbol (L) in Eq. (3) appears to be incorrect, and the Bernoulli distribution notation in Line 218 is not presented in a standard form.
-
The knowledge graph construction is too opaque for a method that relies on it so heavily.
-
The contribution of the mask input to diagnostic performance seems relatively limited.
-
The appendix should provide more interpretable diagnosis examples, including both successful diagnostic cases and failure cases corrected through intervention.
Questions
-
Please clarify the exact implementation of the intervention-aware loss on Page 6.
-
How sensitive is HCEM to the concept of knowledge graph construction?
-
Interpretability validation against medical guidelines. For DR, do the learned disease-concept relations (gray lines in Figure 6) match standard grading criteria (e.g., thresholds of MA/HE/VH for each DR grade)? It would be interesting to quantify alignment, for example, by comparing it to a rule set from clinical guidelines and reporting agreement statistics.
Limitations
Yes
Final justification
Thank you to the author for the response; my concerns have been adequately addressed, and I will keep my original score unchanged.
Formatting concerns
None
2 comments
We sincerely appreciate your valuable comments. Below, we provide clarifications in response to your concerns regarding the clarity and interpretability of our manuscript.
W1: We acknowledge the typographical error in the formula identified by the reviewer and will carefully correct it in the revised version.
W2: This part was not described clearly. Therefore, we clarify the complete construction process. The concept knowledge graph is constructed through three steps. First, a directed conditional co-occurrence matrix is computed from the training data: $ P_{ij}=P(c_j=1\mid c_i=1) =\frac{\sum_{m=1}^{M}\mathbb{I}(c_i^{(m)}=1,c_j^{(m)}=1)} {\sum_{m=1}^{M}\mathbb{I}(c_i^{(m)}=1)}. $ As in general, the matrix captures directional concept-concept relations and provides candidates for inclusion and exclusion. Second, to mitigate class imbalance, limited sample size, and dataset bias, GPT-5.4 combines these statistics with clinical knowledge to generate an initial graph. Finally, clinical experts inspect all candidate relations, remove incorrect edges, and supplement missing ones to ensure clinically valid hierarchical inclusion and exclusion relationships. The concept knowledge graph is presented in Fig. 9.
W3: The mask provides approximately 0.2%–0.7% gains in disease diagnosis and concept recognition. This limitation and a mask-free model are presented in the appendix.
W4: Two examples have already been provided in Fig. 5. More examples will be included in the appendix of the revised manuscript. It should be noted that concept intervention does not always successfully correct erroneous diagnostic predictions in our model.
Q1: During training, incorrectly predicted concept values are replaced with intervention values sampled according to their ground-truth labels, after which disease inference is performed again. Samples whose disease predictions remain incorrect after intervention are identified as intervention-failure cases. For these samples, the latent disease–concept relation matrix is dynamically constructed, and the intervention-aware entailment loss pulls disease-relevant concept embeddings into the entailment cone of the ground-truth disease while pushing conflicting concepts outside it. This design allows disease–concept relationships to be learned adaptively from intervention failures rather than relying on fixed clinical rules.
Q2: This question can be interpreted as an ablation study of the knowledge graph constructed through the three-step pipeline. The results are presented below.
Table R1: Concept knowledge graph ablation on two datasets across three random seeds.
| Method | MFIDDR Disease Acc | MFIDDR Concept mAP | Dem7pt Disease Acc | Dem7pt Concept mAP |
|---|---|---|---|---|
| HCEM w/o data-driven statistics | 0.738±0.010 | 0.729±0.008 | 0.840±0.014 | 0.568±0.011 |
| HCEM w/o GPT | 0.754±0.005 | 0.751±0.004 | 0.867±0.005 | 0.583±0.007 |
| HCEM w/o clinician validation | 0.747±0.008 | 0.750±0.004 | 0.864±0.008 | 0.581±0.006 |
| HCEM | 0.760±0.006 | 0.762±0.007 | 0.875±0.009 | 0.591±0.009 |
Q3: Taking DR diagnosis as an example, we evaluate consistency with three representative clinical rules: no lesion indicates Normal, isolated MA indicates Mild NPDR, and VH or VO indicates PDR. After correcting the relevant concepts to their ground-truth values, we report the accuracy of the corresponding DR grades as a measure of diagnostic consistency. Table R2 shows over 88% DR diagnostic rule consistency, while also revealing a small number of remaining explanation and reasoning errors.
Table R2: Consistency of disease predictions with representative DR grading rules under correct concept information. (Unit: %)
| Method | No Lesion \rightarrow Normal | MA Only \rightarrowMild NPDR | VH/VO \rightarrow PDR |
|---|---|---|---|
| HCEM w/o | 94.4 | 80.7 | 86.2 |
| HCEM | 97.8 | 88.2 | 91.5 |
Thanks for the authors' responses; my concerns have been well addressed.
- Rating
- 5/6
- Confidence
- 5/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- use_inspired
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper presents HCEM, an image diagnosis model built around medical concepts. It maps medical concepts and disease labels into hyperbolic space to capture layered, overlapping and mutually exclusive connections between clinical concepts. Results show the model achieves high accuracy on both concept identification and disease prediction, and it is easier to understand and adjust during practical use.
Strengths and weaknesses
Strengths:
-
The paper is well-written, and the idea is clearly explained. The most important contribution lies in the proposed novel hyperbolic concept modeling method. It addresses a salient limitation of Euclidean CBMs in medical imaging by explicitly modeling hierarchical and entailment relations among concepts. Moreover, the method demonstrates improved accuracy and responsiveness to interventions, which are important for clinical trust and interactive diagnostic workflows.
-
A strength of the method is its clearly defined regularization objectives. By introducing structural constraints on concept relations, the paper encourages the learned concept embeddings to capture hierarchical and entailment patterns, making the model more interpretable and better aligned with clinical knowledge.
-
The empirical evaluation is comprehensive. This work evaluates the method on four public datasets across retinal and dermatology tasks, including DDR, MFIDDR, Derm7pt, and SkinCon. It also reports concept recognition results and intervention curves, providing stronger evidence than end-task accuracy alone.
Weaknesses:
- The intervention-aware concept relation derivation (matrix B) is underspecified. How entailment vs. exclusion is inferred from interventions is not entirely clear, raising concerns about the stability and correctness of the supervision signals.
- To improve the intervention capability of concept-based models, the authors propose an intervention-aware disease-concept regularization method. However, since this objective is specifically designed to enhance intervention performance, the method should be compared with other concept-based models that also target intervention ability, such as Coop-CBM [1], ECBM [2], and DCBM [3].
- Figure 4 shows strong intervention performance, but further failure-mode analysis is needed. The authors should analyze which concepts are most critical for successful interventions and how the model behaves under incorrect concept edits, which would help assess the robustness and safety of the intervention mechanism.
[1] Auxiliary losses for learning generalizable concept-based models. Advances in Neural Information Processing Systems, 2023.
[2] Editable Concept Bottleneck Models. International Conference on Machine Learning, 2025
[3] Deferring concept bottleneck models: Learning to defer interventions to inaccurate experts. Advances in Neural Information Processing Systems, 2026
Questions
- Can the authors supply valid experiments to analyze the influence of low concept accuracy on overall diagnostic results?
- Could the authors rework and clarify the unclear symbolic formulas for random intervention shown in Lines 217–219?
Limitations
Yes. The comparative analysis of HCEM against concept-based interpretable methods is placed in the appendix.
Formatting concerns
No formatting concerns
2 comments
We greatly appreciate your positive assessment of our work and the constructive feedback you have provided. We will respond to each of your concerns in detail.
W1: According to our Intervention-aware Hyperbolic Disease–Concept Regularization, the latent disease–concept relation matrix B is not predefined. Instead, it is dynamically inferred from samples whose disease predictions remain incorrect after concept intervention. For example, consider a patient who is misclassified as Severe NPDR owing to a missed detection of vitreous hemorrhage (VH), although the clinical grading criteria indicate that the correct diagnosis is PDR. If correcting the VH concept still fails to yield a PDR prediction, the proposed regularization introduces an additional hierarchical constraint in hyperbolic space, encouraging the VH embedding to lie within the hyperbolic entailment cone of PDR. This constraint reinforces the supporting relationship between VH and PDR diagnosis. Overall, the disease–concept relations dynamically encoded by B are consistent with established clinical diagnostic rules.
W2: We conduct test-time intervention experiments comparing Coop-CBM and ECBM with our method, and the results demonstrate the superior intervention performance of our method.
Table R1: Disease classification accuracy under different concept intervention rates on MFIDDR and Derm7pt. (Unit: %)
| Dataset | Model | 0.0 | 0.3 | 0.5 | 1.0 |
|---|---|---|---|---|---|
| MFIDDR | Coop-CBM | 72.2 | 73.5 | 75.6 | 77.1 |
| MFIDDR | ECBM | 73.1 | 74.6 | 75.1 | 76.9 |
| MFIDDR | HCEM | 76.0 | 76.8 | 77.3 | 78.5 |
| Derm7pt | Coop-CBM | 84.5 | 84.9 | 86.0 | 87.0 |
| Derm7pt | ECBM | 85.2 | 86.4 | 87.3 | 88.2 |
| Derm7pt | HCEM | 87.5 | 88.0 | 88.6 | 89.0 |
W3: Assessing only the accuracy gain resulting from intervention on a single concept is not clinically meaningful. Intervention effectiveness should instead be examined in the context of clinical diagnostic rules. Taking DR grading as an example, clinical rules indicate that the presence of MA alone corresponds to Mild, whereas the presence of VO indicates PDR. Accordingly, we report the classification accuracies for two grades when the corresponding concepts are predicted incorrectly and correctly, respectively.
Table R2: Disease classification accuracy under incorrect and correct predictions of relevant concepts. (Unit: %)
| Target Grade | Relevant Concept | Concept Incorrect | Concept Correct |
|---|---|---|---|
| Mild NPDR | MA | 36.78 | 65.17 |
| PDR | VO | 68.58 | 89.23 |
Q1: We believe that the test-time concept intervention experiments presented in Fig. 4 and Table R1 sufficiently address this concern.
Q2: We acknowledge that should be replaced with in the original manuscript. We will carefully proofread all equations and symbols in the revised version.
Thanks for the authors' response, my concerns have been well addressed. I will keep my score unchanged.
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 2/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- use_inspired
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper addresses interpretable medical image diagnosis using a concept-bottleneck model approach. Here the prediction is routed through a human-readable concept layer (image to concept to disease) rather than directly mapping images to diagnoses. This is grounded in the observations that medical concepts and diseases are often hierarchically related. That is to say, concepts can include or exclude another concept. A concept can then imply a disease This argues that conventional concept models, which embed concepts and diagnoses in Euclidean space as independent units, are not well suited to this underlying structure in medicine. The author(s) propose HCEM (hyperbolic concept embedding model) for medical image diagnosis, which embeds concepts and diseases in hyperbolic space (using the Lorentz model to represent negatively-curved space with exponential growth that is well suited for a hierarchical structure).
HECM approach extracts concept embeddings from an image (with the option of including or not a key-region mask) maps these into hyperbolic space, and then represents each concept with positive or negative embeddings. Concept predictions are then fused, ie combined into a single concept representation, that is passed along to disease-specific hyperbolic encoders and classifiers, leading to an interpretable reasoning path. The geometry is regularized at 2 levels. At the concept level, a concept knowledge graph (constructed from training set co-occurfrence stats, created with GPT-5.4 and then validated by clinicians) encodes which concepts include or exclude each other. This is enforced through 2 training losses a contrastive loss that separates each concept's present/absent embeddings and an entailment-cone loss that arranges concepts so that an including concept will spatially enclose the concepts it includes. At the disease level, the model practices concept corrected during training, ie an intervention-aware loss trains the model to respond when a concept is corrected. This in effect simulates a clinician fixing a wrong concept and so it effectively learns to update the diagnosis and respond correctly during evaluation. A radial loss controls each disease embedding's position in the hierarchy, i.e. its distance from the center. The model uses fully hyperbolic linear layers, avoiding the distortion from flattening, and Lorentz batch normalization.
The authors evaluate the approach on 4 datasets that are publicly available in 2 fields - dermatology and ophthalmology. Dermatology datasets include both dermoscopic melanoma/nevus (Derm7pt) and standard annotated skin images (SkinCon). Ophtho datasets focus on diabetic retinopathy (DDR, MFIDDR). This is evaluated against 9 baseline models. All methods share the same pretained VGG16 backbone and are evaluated over 3 random seeds. The author/authors report disease classification metrics (accuracy, macro-F1), concept recognition (mean average precision, mAP) and disease accuracy under test-time concept intervention, as well as ablation studies, hyperparameter analysis, and hyperbolic embedding visualizations. HCEM has improved accuracy (76-87% depending on dataset), better concept prediction pre-diagnosis (37 -83%).
The main contributions as described in the paper are a) introducing hyperbolic concept embedding into concept-based interpretable medical diagnosis to enable a hierarchical concept-to-disease approach b) a training strategy that shapes the hyperbolic space to capture relations among concepts and between concepts and diseases, including a component that makes the model responsive to concept interventions c) experiments across 4 medical datasets in 2 medical fields indicate improved concept and disease classification as well as interpretability.
Strengths and weaknesses
Strengths:
The paper has a clear motivation and is built on a sound premise. Medical concepts and diseases are frequently hierarchical and inclusive/exclusive rather than standalone. They can contain sub-concepts or sub-diagnoses; one may be a subset of another, may imply or commonly co-occur with another, or may seldom or never co-occur. Conventional concept-bottleneck models, which embed concepts as independent units in Euclidean space, are not ideal for representing this. Matching a geometry to the presumed structure of the domain is a fundamental overhaul of this task, which is commendable, rather than simply trialing a new modeling technique. The scientific motivation is well-reasoned and really highlights the limitations of a widely used model approach. I found it thought provoking and made me think more of the need to adopt this approach in other models,
The concept and key points are clearly communicated. The motivation for the hyperbolic geometry, the shortcomings of the standard Euclidean approach, and the overall image to concept to disease reasoning pipeline is intended to echo medical reasoning (and in turn how these diagnoses are initially developed). This is written to be understandable to those with or without medical knowledge.
The quality is above the norm. The paper evaluates comprehensively the model on 4 datasets (in 2 clinical fields - ophthalmology/retinal and dermatologic including dermoscopic and plain skin images) against 9 baselines (1 multitask model and 8 concept based method) with 3 seeds, looking at disease classification, concept recognition, and disease accuracy under test-time intervention. The methods all use the VGG16 backbone. Mask-augmented baselines (CMM (concept bottleneck model)+Mask, CEM (concept embedding model)+Mask) and no mask variant are included so the key region mask is not silently creating the advantage. HCEM without the segmentation branch (key region mask, HCEM no mask) continues to outperform the 9 baselines on most of the metrics. It isolates the contribution of the hyperbolic modeling. The consistency of the gain across all 4 datasets speaks to the quality.
The hyperbolic implementation is carefully carried out and is not superficial. This adds to the quality of this work. Unlike some nominally hyperbolic approaches, which may repeatedly flatten data (creating distortion), HCEM keeps its computations in the curved space itself and adds Lorentz batch normalization to stabilize training. The approach accounts for the geometry and fits with the aim of preserving the underlying hyperbolic structure.
The intervention-aware disease-concept objective is a comparatively novel idea, which speaks both to originality and significance. It avoids fixed medical rules, as some approaches rely on. Instead it simulates concept corrections during training and identifies cases where correcting a concept still fails to correct the diagnosis and adjusts the geometry so it responds correctly to those corrections. This makes this disease-concept approach adaptive and something which can be adopted by other models.
Weakness A central concern is that the geometry may not fundamentally capture the medical hierarchy. The concept graph is built from co-occurrence statistics and then relabeled by GPT-5.4 as "inclusion" and "exclusion". (Paper states "we first compute the co-occurrence relationships among concept states, including both presence and absence, from the training data. Then, GPT-5.4 [41] jointly analyzes these co-occurrence statistics and clinical knowledge to generate the initial graph, which clinicians further validate." The paper defines "The graph is represented by an adjacency matrix A: Aij = 1, if node i includes node j, −1, if node i and node j are mutually exclusive, 0, if node i and node j have no direct relevance.") Where it is truly co-occurrence, it would be symmetric rather than an asymmetric "includes" relation. The direction that makes this a graph a hierarchy comes from the LLM, not directly from the data and co-occurrence statistics.
In terms of clarity, the hierarchy is not organized with the high level concept on top and then the descendent sibling concepts below. Most importantly the example that is given in the text to state this concept does not show this sort of hierarchy. The text states "However, existing methods typically model concepts as independent semantic units, thereby overlooking the inherent hierarchical organization and semantic constraints of medical concepts and diseases. Taking DR grading as an example, retinal hemorrhage (RE) can be viewed as a high-level concept that includes finer-grained lesions such as microaneurysms (MA), hemorrhages (HE), and vitreous hemorrhage (VH), reflecting a coarse-to-fine hierarchy. In addition, the presence of RE suggests at least mild NPDR rather than a healthy state, reflecting the inclusion and exclusion relationships. These observations highlight the necessity of hierarchical concept modeling and explicit constraints."
Even without medical knowledge, it should be understood that retinal hemorrhage is a subset of hemorrhage (the larger parent category), likewise vitreous hemorrhage is a subset of hemorrhage. Vitreous and retinal hemorrhages are siblings. Both retinal and vitreous hemorrhages are types of hemorrhage that occur in different compartments of the eye and can co-occur. Placing retinal hemorrhage at the top, as the concept that includes hemorrhage and vitreous hemorrhage, inverts the hierarchy. This is like saying dogs (hemorrhages) are a type of "Dalmatian" dog (retinal hemorrhage) and "German Shepherd" dogs (vitreous hemorrhages) are a type of Dalmatian dog, when in fact the Dalmatian is one dog subtype along with German Shepherd.. Microaneurysms. in turn, are not a type of hemorrhage; they are out-pouchings of vessels more prone to bursting over time which leads to bleeding, ie hemorrhages). As such micro-aneurysms will co-occur with these other findings and can be a predecessor or contributor to hemorrhage. As these co-occur they can be grouped with them statistically, but the relation is not one of containment.
As such it is not clear what the role of the clinician was in reviewing the concept knowledge graph and how they could disentangle this. It may be worth categorizing this as not clear cut hierarchical graphs, but as statistical associations, which may depend on the dataset. Clinician grounding is a part of this paper, but it is not clear how much of a role clinicians played.
Comparing the adjacency matrices to clinical standards would help show how closely this approach is tracking clinical diagnostic reasoning. Some of these connections are not plausible clinically.
The reported improvements are consistent but small. They are not accompanied by accompanied by significance testing (including gains over 2nd best method, as well as Table 2).
The interpretability claim is supported by visualization rather than measurement. There is no clinician reader study; no assessment of whether the concept to disease reasoning is consistent with clinical reasoning.
Smaller clarity and technical points: The intended meaning of the directed edges (containment, co-occurrence) is not clarified.
The gains are small and not shown to be significant. Improvements over the 2nd best method (0.52-1.56%, disease and 1.02-2.09%, concept mAP) over 3 seeds without significance testing.
I'm a little worried that the knowledge-graph is GPT-generated with clinician validation, rather than created by clinician experts, who may have more insight into this approach, if it is indeed novel in the field, but not for clinicians. Further documentation of clinician validation could better show whether this fits with clinical reasoning, which would help with further expansion of this approach, rather than reliance on unstable approaches (like chatgpt which may change with versions).
Questions
Can you tell us more about the involvement of clinicians in validating the concept knowledge graph? They are mentioned but unclear what role they played. How many clinicians validated it? What were they able to change? For instance, can you answer any of the following: Did they add, remove, reverse edges? Did they approve only? How many changes did they make? What changes did they make? How were disagreements resolved? Can you share the graph before and after clinician review?
The concept graph is seeded from co-occurrence statistics (which should be symmetric by nature) and then given directional inclusion/exclusion structure by GPT-5.4. Can you report the raw co-occurrence matrix alongside the final graph, and an ablation comparing (a) the raw co-occurrence graph without LLM relabeling (b) current hybrid? It would be helpful to understand the effect and whether co-occurrence all alone was sufficient. It may be that co-occurrence is what is helping.
Rather than generating the graph from co-occurrence statistics and unspecified clinical knowledge, could the graph be built from the existing clinical structures (ICDR grading criteria, 7 point checklist for Derm7pt, Bolognia morphology for SkinCon). This could be derived directly or could use an LLM for assistance. Has this been considered?
For the denser graphs (Derm7pt and SkinCon), if you hide some of the graph's edges during training does the learned embedding recover them? It would help show whether the geometry generalizes the relations or mainly reproduces them.
The paper describes retinal hemorrhage as a high-level concept that includes hemorrhage, vitreous hemorrhage, and microaneurysm. Clinically, hemorrhage is the parent category while retinal and vitreous hemorrhage are sibling subtypes and microaneurysm is a distinct lesion that can be a predecessor to and a cause of hemorrhage. Could you clarify the intended subordinate concept and what each graph edge is intended to encode?
The improvements over the second best method are computed over 3 seeds, without significance testing. Can you provide paired significance tests or bootstrap intervals to add standard dev to the table?
The appendix describes kappa as "the most important" parameter but Table 6 shows small variation across fixed values and only 0.2-0.4 gain for learnable kappa over the best fixed setting. Could you reconcile this and report the learned kappa per dataset?
Could you clarify the novelty of the work here relative to other papers in the field? Yu et al (MICCAI 2022) and Ganea et al (2018) perhaps? There is clearly novelty (concept knowledge graph approach) but would be clearer with a more detailed picture of the landscape https://link.springer.com/chapter/10.1007/978-3-031-16437-8_57 and https://arxiv.org/abs/2209.05842 https://proceedings.mlr.press/v80/ganea18a.html
Limitations
Partially. The authors note dependence on annotated data (which will make this difficult to replicate in other fields) and are transparent about the LLM generated graph, but some limitations are not surfaced. The geometry is not shown to capture genuine hierarchy rather than a co-occurrence; the latter may be sufficient but it should be framed differently. The extension of clinician validation is undocumented and including more information on this would be very helpful. Interpretability is shown not measured and accuracy is modest and not tested for significance. No major societal impact concerns, beyond what AI and clinical diagnostic/decision support creates.
Final justification
Thank you for the authors' response. I will keep my score unchanged.
Formatting concerns
There are some: Figure 1 Not clear that this is a photo of a retina or that these labels represent Identify table where abbreviations explained with first use
Fig 2 Benign, Non-neoplastic (p in neoplastic), Malig-nant (break should be with syllable)
Skinion in Figures but SkinCon elsewhere
1 comment
Rebuttal
Clarification of Concept–Concept and Disease–Concept Hierarchical Relationships: First, we clarify that the inclusion and exclusion relations defined in this work mainly capture semantic hierarchical structures, comprising vertical relations across different semantic levels and lateral relations among concepts within the same level. Such clinical hierarchical relations constitute only a special case of semantic hierarchical relations. The inclusion relation indicates that one concept semantically entails or is subordinate to another, whereas the exclusion relation indicates a semantic conflict between two concepts. The MA example in the original manuscript may have been inaccurate and potentially misleading. We will clarify the unidirectional hierarchical relationship in the revision.
For concept–concept relationships, the knowledge graph constructed in this work primarily captures directional semantic inclusion and exclusion relationships. Taking DR diagnosis as an example, retinal hemorrhage can be regarded as a higher-level concept, whereas retinal hemorrhagic spots and vitreous hemorrhage represent more specific manifestations of hemorrhage (HE). Vitreous hemorrhage (VH) generally indicates more severe hemorrhagic changes, while the reverse inference does not hold. Similarly, in Derm7pt, an atypical pigment network can be categorized as a pigment-network abnormality; irregular dots and globules, irregular streaks, and irregular blotches can be grouped as pigment-distribution abnormalities; and an atypical vascular pattern can be categorized as a vascular-structure abnormality. In addition, semantically opposite states of the same attribute, such as typical and atypical pigment networks, are generally mutually exclusive. It should be noted that these relationships include both hierarchical relationships across different semantic levels and lateral relationships among concepts at the same semantic level. Together, they form a comprehensive semantic relational structure that is consistent with clinical knowledge. By imposing constraints on these semantic inclusion and exclusion relationships, the model can learn hyperbolic concept embeddings that are more coherent, accurate, and clinically meaningful. For disease–concept hierarchies, we model the unidirectional semantic support (inclusion) and opposition (exclusion) of concepts for disease categories. For example, MA generally supports Mild NPDR, whereas VH provides stronger evidence for PDR. Rather than assuming symmetric equivalence, hyperbolic hierarchical constraints align disease representations with their key diagnostic evidence.
Clarification of the Misunderstood Co-occurrence Relationship: The first step in constructing the concept knowledge graph is not to compute symmetric co-occurrence frequencies, but to calculate asymmetric conditional co-occurrence probabilities between concepts, i.e., the probability that concept is present given the presence of concept , . Specifically, we construct a directed conditional co-occurrence matrix from the training data, where , and denote the numbers of samples and concepts, respectively, and is the indicator function. Since generally holds, this statistic captures potential directional semantic relationships between concepts. Specifically, a high and a low indicate that is commonly accompanied by , whereas the reverse does not hold, suggesting a unidirectional semantic inclusion or entailment relationship rather than only a clinical superordinate–subordinate relationship. Low probabilities (0) in both directions may instead indicate mutual exclusion.
Roles of GPT and Clinicians: Because these statistics may be affected by class imbalance, sample size, and dataset bias, GPT-5.4 combines conditional co-occurrence statistics with clinical knowledge, such as the ICDR grading criteria and the Derm7pt checklist, to preliminarily determine the type and direction of concept relations. A clinician then reviews their medical validity and corrects relations inconsistent with clinical semantics. For example, the first two steps identified the candidate relations “HE includes VH” and “VO includes SE”; the clinician retained the former and removed the spurious “VO includes SE” edge. We will provide full implementation details and pseudocode in the appendix. It should be emphasized that clinician validation ensures the medical validity of the final concept graph and rules out the clinically erroneous relations suggested by the reviewer. We will include the concept graph before revision, together with further construction details, in the appendix.
Why Use Semantic Relations Instead of a Strict Clinical Hierarchy? 1) Semantic relations are consistent with interpretable clinical reasoning by modeling the associations and diagnostic pathways among concepts. 2) Since hyperbolic concept embedding essentially models semantic structures, a semantic-relation-based concept graph can regularize the embedding space and improve both concept prediction and hierarchical consistency, without requiring a fully defined clinical hierarchy.
Why Not Let Clinicians or LLMs Construct It Directly? In our semi-automated three-stage pipeline, clinicians are responsible only for verification. Although clinicians can directly construct the graph in domains with few concepts, such as DR. However, manually handling dozens or hundreds of fine-grained concepts is highly time-consuming. In contrast, direct LLM generation may produce hallucinated concept relations. We therefore perform ablation studies to validate the necessity of all three stages.
Table R1: Concept knowledge graph ablation on two datasets in three seeds.
| Method | MFIDDR Disease Acc | MFIDDR Concept mAP | Dem7pt Disease Acc | Dem7pt Concept mAP |
|---|---|---|---|---|
| HCEM w/o data-driven statistics | 0.738±0.010 | 0.729±0.008 | 0.840±0.014 | 0.568±0.011 |
| HCEM w/o GPT | 0.754±0.005 | 0.751±0.004 | 0.867±0.005 | 0.583±0.007 |
| HCEM w/o clinician validation | 0.747±0.008 | 0.750±0.004 | 0.864±0.008 | 0.581±0.006 |
| HCEM | 0.760±0.006 | 0.762±0.007 | 0.875±0.009 | 0.591±0.009 |
Edge hiding in the Concept Knowledge Graph: Under incomplete concept-relation constraints, both concept prediction and disease diagnosis performance decrease, as shown in Table R1. However, visualizations of the concept and disease embeddings suggest that the learned geometry can still implicitly recover some of the missing relations among concepts. We will add these visualizations and comparisons with the complete-graph setting to the appendix.
Significance and Improvements in Disease Diagnostic Metrics: We conducted statistical significance tests against VLM-GCR and Evi-CEM, which ranked second on most metrics. HCEM achieved significant improvements in all eight comparisons across the four datasets, with all results remaining significant after BH-FDR correction (q<0.05), confirming the statistical reliability of its performance advantages. As shown in Fig. 3 of this paper, the gains in concept classification are even larger, with mAP improving by approximately 1%–3% over these two methods. We will include statistical significance tests for all experiments in the revised manuscript.
Table R2: Disease diagnosis performance of HCEM, VLM-GCR and Evi-CEM on four datasets. The q-values are calculated by applying BH-FDR correction to all eight comparisons between HCEM and the strongest baseline.
| Dataset | Metric | Evi-CEM | VLM-GCR | HCEM (Ours) | q-value |
|---|---|---|---|---|---|
| DDR | Acc | 82.23±1.26 | 83.10±0.74 | 84.52±0.79 | q<0.05 |
| DDR | F1 | 71.88±1.34 | 73.58±0.86 | 75.01±0.92 | q<0.01 |
| MFIDDR | Acc | 74.21±1.12 | 75.47±0.61 | 76.02±0.58 | q<0.05 |
| MFIDDR | F1 | 56.02±1.20 | 56.78±1.51 | 58.34±0.67 | q<0.005 |
| Derm7pt | Acc | 85.79±1.46 | 85.24±1.43 | 87.52±0.89 | q<0.001 |
| Derm7pt | F1 | 83.10±1.68 | 82.05±1.68 | 84.76±0.89 | q<0.001 |
| SkinCon | Acc | 78.51±1.52 | 76.41±1.35 | 79.09±0.81 | q<0.05 |
| SkinCon | F1 | 57.23±1.29 | 56.28±0.97 | 58.32±1.30 | q<0.005 |
Lorentz Curvature Hyperparameter : Clearly, the most important hyperparameters in HCEM are the weights of the two regularization terms. The Lorentz curvature parameter also affects performance, as you noted. We will report the final values in the revised appendix.
Novelty: Compared with the work of Yu et al., we are the first to introduce hyperbolic space into CBMs and employ a knowledge graph to constrain hyperbolic concept and disease embeddings. The similar work of Ganea et al. has already been discussed in our related work section.
Limitation: We adopt public datasets with concept annotations and publicly available data splits. The code, complete concept knowledge graphs, and their construction pipeline will also be released to facilitate full reproducibility.
Paper Formatting Concerns: We will thoroughly address the unclear illustrations and the misspelling of “SkinCon” identified by the reviewer in the revised manuscript.
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 2/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper proposes HCEM, a hyperbolic concept embedding model for interpretable medical image diagnosis that captures hierarchical relationships among medical concepts and diseases. By combining hyperbolic representations with concept-structure and intervention-aware regularization, the model improves medical diagnosis prediction Experiments on four medical datasets show that HCEM provides more accurate and interpretable diagnostic reasoning.
Strengths and weaknesses
Strengths
-
The use of hyperbolic space is well motivated because medical concepts often form hierarchical, tree-like structures, and hyperbolic space can better represent such hierarchical relationships than Euclidean space.
-
The paper designs an end-to-end pipeline combining data-driven co-occurrence statistics, LLM-based graph construction, clinician validation into a medical diagnosis in a concept graph.
Weaknesses
-
The motivation for using this hybrid pipeline is insufficiently justified. The paper should explain why expert-curated resources such as UMLS are unsuitable or incomplete.
-
Moreover, the paper does not clearly distinguish the respective contributions of data-derived co-occurrence statistics, GPT-5.4, and clinician validation to the final concept graph. Please provide details on these procedures.
-
The ablation study does not include the procedures of relation graph structure.
-
The ablation study does compare the proposed model with Lorentz hyperbolic space and the baseline with Euclidean space. it is not clear whether the hyperbolic space bring benefits.
Questions
- I am still confused with the difference between concepts and diseases.
It seems that symptom is a medical concept, and why it is not a disease?
-
How did we determine the number of concepts and diseases, i.e., N and K?
-
What is the difference of concept–concept and disease–concept?
-
What is the concept encoder F_c and what is the specific architecture / configuration?
Limitations
Same as above.
Final justification
It has cleared my concerns and I adjust the scores.
Formatting concerns
NA
1 comment
Rebuttal
Thank you for your professional response and constructive comments. We will address your concerns from the following perspectives.
Definitions and Differences between Concepts and Diseases (Q1): In our framework, medical concepts refer to clinically interpretable intermediate observations, including symptoms, lesions, signs, and attributes, whereas diseases refer to the final diagnostic categories inferred from these observations. Therefore, symptoms are treated as medical concepts because they generally provide disease-related evidence but are insufficient on their own to establish a definitive diagnosis. For example, hemorrhages (HE) and microaneurysms (MA) are considered lesion concepts, or fundus manifestations, whereas non-proliferative diabetic retinopathy (NPDR) and proliferative diabetic retinopathy (PDR) represent different stages of progression in diabetic retinopathy (DR). In skin images, papules, plaques, ulcers, crusts, brown pigmentation, and erythema are medical concepts, while non-neoplastic, benign, and malignant are skin cancer categories. Since the same symptom may be associated with multiple diseases, the model needs to integrate multiple concepts through the reasoning pathway of “image → concept → disease” to obtain the final diagnosis.
The number of Concepts and Diseases (Q2): The number of concept and disease classes follows the specialist annotations of each dataset. Derm7pt has 26 concepts and 2 diseases, SkinCon has 22 concepts and 3 diseases, and DDR and MFIDDR each have 6 lesion concepts and 5 DR grades, as defined in [1] and [2].
Concept–Concept and Concept–Disease Relationships (Q3): Concepts may exhibit inclusion, mutual exclusion, or no explicit relationship. Inclusion or entailment is directional. For example, vitreous hemorrhage (VH) usually implies hemorrhage (HE), but the reverse does not necessarily hold. Mutual exclusion means that two symptoms cannot coexist, whereas bidirectional inclusion indicates that they must occur together. Such inclusion relationships can also capture the hierarchical structure among concepts. Disease–concept relations describe whether a concept supports, opposes, or is irrelevant to a diagnosis. In essence, this relationship reflects whether a concept constitutes diagnostic evidence for a disease or is mutually exclusive with its diagnosis. For example, vitreous hemorrhage (VH) or opacity (VO) indicates PDR. Mild NPDR is characterized by MA only and no other lesions.
Concept Encoder (Q4): The backbone network (VGG16) first extracts the hidden feature , where and denote the batch size and the number of feature channels, respectively. Global average pooling is then applied to reduce the spatial dimensions from to , followed by flattening to obtain . Next, parallel fully connected layers generate 128-dimensional Euclidean concept embeddings, denoted as , where is the number of concepts. Finally, each concept embedding is evenly split along the channel dimension into supportive and opposing concept embeddings, yielding .
Detailed Process of Concept Knowledge Graph Construction (W2): The concept knowledge graph is constructed through a hybrid pipeline that integrates data-driven statistical analysis, clinical-knowledge-informed LLM generation, and clinician validation. 1) To identify potential inclusion and exclusion relationships among medical concepts, we first construct a directed conditional co-occurrence matrix from the training data. Let the training set contain samples and medical concepts, and let denote whether concept is present in the -th sample, where and indicate presence and absence, respectively. Each matrix entry is defined as , where is the indicator function. The numerator counts the samples in which and are simultaneously present, while the denominator counts all samples containing . Since is generally different from , the matrix captures directional concept relationships: a high but low suggests that is a more specific subordinate concept included by the more general concept . Low probabilities in both directions indicate potential mutual exclusion, whereas high probabilities in both directions indicate strong co-occurrence or approximate semantic equivalence. 2) Relying solely on the training data may be affected by class imbalance, insufficient sample size, and dataset bias. In the second step, GPT-5.4 generates an initial concept graph based on the statistical co-occurrence relationships and domain-specific clinical knowledge. Clinical knowledge is used to determine whether the observed associations have reasonable clinical semantics, thereby preventing incidental co-occurrences from being misidentified as stable relationships between concepts. 3) GPT-5.4 is used only to assist in generating candidate relationships, while all relationships in the final graph are inspected and confirmed by clinical experts. In this step, edges erroneously introduced or omitted in the preceding steps are removed or supplemented to ensure clinically meaningful hierarchical inclusion and exclusion relationships. The full knowledge graph is shown in Fig. 9 of the manuscript.
Why not directly use Expert-Curated Resources (W1): UMLS mainly supports general medical terminology integration and semantic mapping, but does not directly capture task-specific fine-grained concept states, directional inclusion, or exclusion relations, and its terminology is not fully aligned with our dataset annotations. For example, in SkinCon, complex relations such as a papule being a specific type of elevated lesion and its distinction from a flat macule are not explicitly encoded.
Ablation Study of the Concept Knowledge Graph (W3): Since this pipeline is relatively engineering-oriented, we will provide complete pseudocode and detailed descriptions in the appendix. Here, we present an example of knowledge graph construction for the DR grading task, together with the corresponding ablation experiments. In the first two steps, we identify the hierarchical relations that HE includes VH and MA, and that VO includes SE. During expert review, the spurious edge indicating that VO includes SE is removed.
The ablation results in Table R1 show that all three stages contribute to HCEM, with data-driven statistics yielding the largest performance gains across both datasets. GPT assistance and clinician validation further improve disease diagnosis and concept recognition, confirming the effectiveness of the hybrid graph construction pipeline.
Table R1: Concept knowledge graph ablation on two datasets in three seeds.
| Method | MFIDDR Disease Acc | MFIDDR Concept mAP | Dem7pt Disease Acc | Dem7pt Concept mAP |
|---|---|---|---|---|
| HCEM w/o data-driven statistics | 0.738±0.010 | 0.729±0.008 | 0.840±0.014 | 0.568±0.011 |
| HCEM w/o GPT | 0.754±0.005 | 0.751±0.004 | 0.867±0.005 | 0.583±0.007 |
| HCEM w/o clinician validation | 0.747±0.008 | 0.750±0.004 | 0.864±0.008 | 0.581±0.006 |
| HCEM | 0.760±0.006 | 0.762±0.007 | 0.875±0.009 | 0.591±0.009 |
Ablation study of hyperbolic and Euclidean spaces (W4): In fact, these ablation results have already been reported in Table 2 under “Baseline” and “Baseline w/ hyperbolic”. Here, we provide supplementary results in Table R2. We find that introducing only the Lorentz hyperbolic space improves performance by 0.7%–1.0% over the Euclidean baseline. Further incorporating hyperbolic concept and disease structure regularization yields additional gains of 1.2%–2.1%, resulting in overall improvements of 1.9%–2.9%.
Table R2: Ablation study of hyperbolic and Euclidean spaces for HCEM.
| Method | MFIDDR Disease Acc | MFIDDR Concept mAP | Dem7pt D. Acc | Dem7pt Concept mAP |
|---|---|---|---|---|
| Baseline (CEM) | 0.741±0.005 | 0.737±0.011 | 0.846±0.015 | 0.565±0.014 |
| Baseline w/ hyperbolic | 0.748±0.003 | 0.745±0.009 | 0.854±0.012 | 0.575±0.007 |
| HCEM | 0.760±0.006 | 0.762±0.007 | 0.875±0.009 | 0.591±0.009 |
[1] Vision-language models guided graph concept reasoning for interpretable diabetic retinopathy diagnosis. AAAI 2026.
[2] Evidential concept embedding models: Towards reliable concept explanations for skin disease diagnosis. MICCAI 2024.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Dear AC,
We have addressed all the concerns summarized in your meta-review, and our responses have been acknowledged by all reviewers. Detailed explanations are provided in our individual responses to the reviewers.