potentialpaper

From Articulated Kinematics to Routed Visual Control for Action-Conditioned Surgical Video Generation

Bohan Li, Shuojue Yang, Baorui Peng, Xianda Guo, Erli Zhang, Youqi Tao, Junfeng Duan, Daguang Xu, Qi Dou, Xin Jin, Wenjun Zeng, Hao Zhao, Yueming Jin

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

Abstract. Action-conditioned surgical video generation is a critical yet highly challenging problem for robotic surgery. The core difficulty is that low-dimensional control vectors must precisely govern complex image-space evolution. In this work, we propose a kinematic-to-visual lifting paradigm that converts articulated kinematics into a unified set of five image-aligned control modalities. Building on this representation, we introduce a hierarchically routed visual control framework that selectively activates the most relevant control modalities and motion scales. Instead of uniformly applying all control signals, our model performs hierarchical routing to dynamically allocate conditioning capacity. We further design kinematic-prior-guided routing loss functions to ensure physically meaningful, temporally stable, and efficient expert utilization. To improve efficiency, we propose a budgeted training and inference scheme that leverages routing-induced sparsity. By selectively discarding low-significance control pathways during training and execution, our approach enables adaptive computation that is complementary to standard distillation. We additionally construct a new benchmark with curated articulated annotations, obtained through human-in-the-loop semantic labeling and differentiable pose tracking, providing realistic supervision for action-conditioned surgical video generation. Extensive experiments demonstrate that our method consistently improves action faithfulness, visual fidelity, and cross-domain generalization over diverse baselines. Moreover, our efficient variant achieves substantial reductions in latency while maintaining strong control accuracy.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
16 Apr 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:48 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

The authors are invited to provide further clarifications on questions raised. These include: justification of what the best downstream applications should be (R1, R2, R3); justification of not using datasets with full 3D kinematics (R2); justifications/missing information on key design choices and evaluation protocols (R2, R3); missing evidence on fidelity for actions such as "knotting", "needle grasping", and "needle puncture" (R2); robustness to imperfect data; dealing with obstruction or non-granular kinematics (R3); role of human-in-the-loop (R3).

Final justification

After the rebuttal, most raised concerns are believed to have been properly addressed. While there are remaining concerns over whether the paper is self-contained within 9 pages, based on the overall contribution and respecting the differences among fields and necessary context needed, the paper is still worth being included.

Area Chair tDoa · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

The authors are invited to provide further clarifications on questions raised. These include: justification of what the best downstream applications should be (R1, R2, R3); justification of not using datasets with full 3D kinematics (R2); justifications/missing information on key design choices and evaluation protocols (R2, R3); missing evidence on fidelity for actions such as "knotting", "needle grasping", and "needle puncture" (R2); robustness to imperfect data; dealing with obstruction or non-granular kinematics (R3); role of human-in-the-loop (R3).

Final justification

After the rebuttal, most raised concerns are believed to have been properly addressed. While there are remaining concerns over whether the paper is self-contained within 9 pages, based on the overall contribution and respecting the differences among fields and necessary context needed, the paper is still worth being included.

Reviewer NUMuOpenReview ↗
Rating
5/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper presents a method to govern surgical video synthesis with low-dimensional kinematics. The kinematics are converted into five control modalities aligned with the images. These modalities are selectively activated based on visual relevance and motion scales.

Strengths and weaknesses

Strengths:

  1. Transforming kinematics into fields that can condition video generation.
  2. Routing the kinematic fields to selectively condition according to physical modality and motion scale.
  3. Hierarchical routing strategy.
  4. Innovative approach to characterize the kinematic signal into information useful for describing how the video frames should evolve.
  5. Good ablation and efficiency studies.

Weaknesses:

  1. Unclear what happens when some parts of an instrument are obstructed or when the kinematics are not as granular as what can be obtained from a robot, e.g., laparoscopic instruments with fewer component parts.
  2. Unclear details on kinematics in the dataset used.
Questions
  1. The authors briefly mention segmentation as a conditioning signal and explain it relies on "expensive annotations". These annotations used to be expensive before foundation models have become widely available. Shouldn't models using segmentation as conditioning be a baseline for that proposed in this paper?
  2. What is the frequency and dimensionality of kinematics in the dataset used?
  3. What if the kinematics were not aligned with the video during recording or because of post-processing the recorded video/kinematics data?
  4. The role of the human in the loop is unclear. The sensitivity of the method to this human in the loop is unclear.
  5. Sensitivity of the method to errors in differentiable pose tracking is not clear.
  6. Differences between SAR-RARP and GraSP are unclear to evaluate Table 4.
  7. Basis for choice of the baseline comparator models is unclear.
Limitations

Yes.

Final justification

The authors' responses and proposed revisions address my questions.

Formatting concerns

None

1 comment
Authors · RebuttalOpenReview ↗
Rebuttal

Thank you for the constructive comments. We address the seven questions in order, followed by the stated concern about obstruction and lower-granularity kinematics.

1. Segmentation-conditioned baseline

As shown in Sec. 4.1 and Table 1, the submission already includes dense-condition baselines (†), including SurgSora† and OpenSora-2.0† with semantic, depth, and flow inputs. As suggested, we add a part-semantic-only OpenSora ablation under the same protocol:

Condition Class-macro CD ↓ Class-macro TI ↑ Class-macro AF ↓
OpenSora-2.0, text only 138.88 0.57 13.70
OpenSora-2.0 + part-semantic only 105.62 0.81 5.78
OpenSora-2.0† + semantic/depth/flow 88.77 0.86 5.20
KVLR 86.90 0.89 4.48

The semantic-only condition uses the same part-semantic representation as the dense-condition baselines, with depth and flow removed. We will add this row to the comparison and its construction to revised Sec. D.1.

2. Kinematic frequency and dimensionality

As described in Sec. 2.2, video and action states are aligned frame by frame at 30 Hz. For each instrument, the 9D action is defined as:

at=[pt,rt,qtsw,qtlg,qtrg]∈R9,a_t = [p_t, r_t, q_t^{sw}, q_t^{lg}, q_t^{rg}] \in \mathbb{R}^{9},

where pt∈R3p_t\in\mathbb{R}^3 is translation, rt∈R3r_t\in\mathbb{R}^3 is axis-angle orientation, and the final three scalars are the shaft-to-wrist and two gripper joint states. Thus each frame contributes nine scalar kinematic values per instrument.

3. Temporal misalignment

For KASA, Differentiable Pose Tracking (DPT) recovers one action state per video frame. For robot logs, timestamps are synchronized and states are interpolated to the video clock. We quantify residual misalignment by offsetting the conditioning sequence by one and two frames:

Action timing CD ↓ TI ↑ AF ↓ Endpoint err. (px) ↓ Direction acc. (%) ↑
Aligned 86.90 0.89 4.48 9.13 84.8
±1-frame offset 93.55 0.86 5.21 10.86 79.2
±2-frame offset 99.82 0.82 5.94 12.74 74.1

The ± rows average symmetric shifts. Shifted clips are cropped without circular wrap and evaluated on the common frame subset. These 33/67 ms offsets quantify the effect of synchronization error at 30 Hz.

4. Human-in-the-loop role and sensitivity

As described in Sec. 3, Human-in-the-loop Semantic Annotation (HSA) is used during offline KASA construction. Human annotators correct SAM2 part swaps, leakage, and propagation failures; the refined masks provide part-aware evidence for DPT to recover the 9D action. KVLR is then trained and evaluated using Kinematic-to-Visual Action Fields (KVA-Fields) rendered from the recovered or supplied actions.

We rerun DPT on 89 scenes (118 frames each; 10,502 frame-level pose comparisons) with SAM2-only versus HSA-refined masks, while keeping the instrument computer-aided design (CAD) model, intrinsics, initialization, optimization, and recovery criteria fixed:

Comparison Result
Scenes with ≥1 tracking-loss event, SAM2-only 41/89 (46.1%)
Scenes with ≥1 tracking-loss event, HSA-refined 0/89 (0%)

The revised Secs. E.3 and E.5 will include the comparison protocol and event definition.

5. Sensitivity to errors in Differentiable Pose Tracking

To isolate how DPT pose errors propagate to generation, we perturb the recovered 9D pose input and regenerate all KVA-Field channels. The perturbed trajectory is used only as the generation input; CD and action-recovery errors remain referenced to the original clean trajectory and real video:

Input CD ↓ TI ↑ AF ↓ Trans. recovery (mm) ↓ Rot. recovery (°) ↓
Clean 86.90 0.89 4.48 5.37 7.81
Translation perturbation, 1 mm/axis 88.38 0.87 4.92 6.12 8.65
Translation perturbation, 3 mm/axis 91.74 0.82 5.87 8.34 10.52
Translation perturbation, 5 mm/axis 97.31 0.79 6.35 9.85 12.73
Rotation perturbation, 1° 87.15 0.86 5.12 6.58 9.12
Rotation perturbation, 3° 91.68 0.81 6.25 9.15 11.38
Rotation perturbation, 5° 98.42 0.77 6.82 10.06 12.91

Translation noise is added per axis, rotation perturbations are composed on SO(3), and velocity/acceleration are recomputed. Complementarily, on CRCD, CD changes from 93.60 with real forward kinematics (FK) actions to 98.85 with DPT-reconstructed actions, providing an end-to-end estimate of the effect of empirical DPT errors. The full protocol will be included in Sec. F.8.

6. SAR-RARP versus GraSP

SAR-RARP supplies the in-vivo robot-assisted radical prostatectomy (RARP) videos and action segments used to construct KASA. GraSP contains independently collected cases with different tissue appearance, illumination, viewpoint, acquisition, and annotation. Table 4 evaluates compatible GraSP knotting and needle-puncture segments without GraSP fine-tuning or human correction; it therefore measures cross-dataset scene/domain transfer under familiar action primitives. We will state this subset directly in revised Sec. 4.2 and Table 4.

7. Basis for baseline selection

The baselines cover three conditioning regimes:

  1. Text-conditioned foundation models test whether language and video priors alone produce action-consistent videos.
  2. Raw-action variants (*) use a parameter-matched ControlNet-style branch to test direct low-dimensional kinematic injection.
  3. Dense visual-condition variants (†), including SurgSora and OpenSora-2.0, test semantic/depth/flow conditioning.

As described in Sec. 4.1, all methods use the same operation-disjoint KASA split and reference-frame/text protocol. Table 1 compares these three conditioning regimes, while the parameter-matched architecture ablation in Table 6 isolates raw-action injection, KVA-Field lifting, Tier-1 modality routing, and Tier-2 motion-scale routing.

Additional concern: partial obstruction and less granular kinematics

As described in Sec. E.4, DPT combines part-aware fitting with a keyframe memory pool to maintain or reinitialize tracking when instrument parts are temporarily obstructed. With supplied robot states, the conditioning trajectory remains available throughout visual obstruction. For instruments with fewer physical degrees of freedom, structurally nonexistent joint channels are held constant within the same interface.

Reviewer cvqQOpenReview ↗
Rating
3/6
Confidence
4/5
Quality
3/4
Clarity
2/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The paper presents a surgical video action generation pipeline (KVLR) with its key contribution being the use of video-derived kinematics, semantics and depth information to guide the generation of the surgical tool motion so as to faithfully represent expert clinical actions. For its development the paper curates and contributes a benchmark (KASA) of video samples taken from an existing surgical video benchmark (SAR-RAPR50). Although the concept of action conditioned generation is not new and previous methods have shown use of kinematics to generate surgical videos the paper makes an interesting approach via the process of routing the most relevant control modalities for the MoE.

Strengths and weaknesses

The approach to condition surgical generation with routed semantic tool information depth and kinematics is intuitive. The contribution of the KASA benchmark is also important. The validation is comprehensive and results show tangible benefits over the competition.

My main concern is that it this is not a self-contained paper within the 9-page NeurIPS limit. The paper has a 20-page appendix, which I know is not uncommon for NeurIPS, but this includes information that are essential to understand the framework. The appendices B-D, F provides key definitions and design strategies which effectively extend the paper beyond what is permitted by NeurIPS.

My overall assessment is that this is an interesting piece of work, however I dont find the current submission appropriate for NeurIPS.

Questions
  • The video-based extraction of kinematics is fundamentally a limitation. Its unclear to what extend the generated 3D trajectories from DPT are accurate ? There are many available surgical datasets from training settings (e.g. JIGSAWS, CRCD (https://arxiv.org/html/2412.12238v1) that provide full 3D kinematics from the dVRK. The framework should be evaluated there with true trajectories. I understand that SAR-RARP is from real cases but this is not the best dataset to validate your method.

  • The DTP methods only explained in E.4 contains many unclear elements.How can DPT generated metric scale trajectories (in mm, - Table 10 in F.1 ) from monocular videos ? This part is also very unclear how would be applied in a an unseen video:
    "Temporal coherence is introduced in two ways. First, the initial frame is anchored using Perspective-n-Point initialization from manually specified wrist keypoints. Second, for subsequent frames, we propagate pose estimates using temporally local correspondences."

  • What is the generation horizon ? how many frames without paired/corresponding kinematics grounding can be generated or is the video generation restricted only on the input trajectory (articulated action sequence a1:T) ? This is an important question which also affects the framework's usability.

  • I am a bit sceptical on the practical applications of this. I dont fully understand the "what-if scenarios" paired with Fig.6. The framework needs a sequence of kinematics a text prompt and a reference frame to generate a video. In deployment how is this sequence of kinematics expected to be available ? Am I missing something here ?

  • I understand the concept of the model zero-shot extending to supposedly "different unseen actions" in the GraSP dataset, though its unclear which part of GraSP is used and which actions are different and also and more importantly the video to derive kinematics from is already available.

  • I am also a bit unclear on the evaluation protocol used. Why is CD used ? Why dont the authors employ standard 3D translation and rotation trajectory metrics to evaluate synthesized tool motion ? Table 10 in appendix F.1 does not compare with other methods just shows video-action regressors.

  • An important selling point of the paper is the ability to generate surgical actions with high fidelity, yet there is no evaluation if the generated actions represent actual "knotting", "needle grapsing" and "needle puncture" actions ? To me this should have been the main evaluation approach coupled with the previous point on kinematics accuracy. Specifically:

  1. Is the model able to generate full "knotting", "needle grapsing" and "needle puncture" actions or only parts of it ? Is the training/testing split carried out in terms of actions to allow for this ?

  2. How would an action quality model recognize the generated frames from KVLR and the competition ?

  • Is it one model are trained or individuals ones for "knotting", "needle grapsing" and "needle puncture" validation ? If its three which one is used for zero-shot ?
Limitations

Partially, limitations are discussed in the appendix from a generic point of view of surgical world models limitations.

Final justification

The authors rebuttal clarified a lot of crucial points on the method design, motivation, intended application and validation. Their integration to the 9-page paper would be critical so that the paper is explained property.

More broadly my overall opinion of the paper has not shifted much. I do believe this is a very good work with important technical contributions. Its actual clinical applicability is still a long way. My main concern remains the paper's self-sufficiency and the rebuttal add a bit more complexity to this. For the authors to integrate all rebuttal points and especially point 1 would require considerable re-writing of Sec 2,3 and 4 and I am still not convinced without having seen the final version that the paper would be self-sufficient or to what extend this would constitute a different 9-page paper.

Formatting concerns

My main concern of the paper is that it this is not a self-contained paper within the 9-page NeurIPS limit. The paper contains a 20-page appendix whit information that are essential to understand the work carried out.

2 comments
Authors · RebuttalOpenReview ↗
Rebuttal

Thank you for the detailed questions. We first address self-containedness, then the requested clarifications and synchronized-trajectory evaluations.

1. Self-containedness within the page limit

We appreciate this concern. The components and protocols are present, but some key definitions are dispersed between the paper and supplement; this is primarily a presentation issue. We will correct it within the unchanged nine-page limit.

Revised Secs. 2.1–2.2 will define the 9D action, horizon, and deterministic Kinematic-to-Visual Action Field (KVA-Field) construction: forward kinematics (FK) poses the computer-aided design (CAD) skeleton; projection/rasterization produces three semantic channels, camera-frame depth, and one articulation channel encoding the wrist/left/right-gripper angle on the corresponding segment; dynamics contain perspective-projected u/vu/v and depth velocity plus 3D keypoint-acceleration magnitude. In particular, u˙=(fxX˙−(u−cx)Z˙)/Z\dot u=(f_x\dot X-(u-c_x)\dot Z)/Z and v˙=(fyY˙−(v−cy)Z˙)/Z\dot v=(f_y\dot Y-(v-c_y)\dot Z)/Z. Sec. 3 will include metric initialization, offline Human-in-the-loop Semantic Annotation (HSA)/Differentiable Pose Tracking (DPT), and the logged-state pathway; Sec. 4.1 the operation-disjoint split, metrics, and baseline inputs; and Sec. 4.2 compact CRCD [Oh et al., 2024] and complete-action results. We will make room by condensing repeated narration.

2. Why video-derived kinematics; validation and generation with real robot trajectories

Our strategy separates the target visual domain from log-referenced validation. The suggested datasets do not match in-vivo robot-assisted radical prostatectomy (RARP) suturing: the JHU-ISI Gesture and Skill Assessment Working Set (JIGSAWS) [Gao et al., 2014] uses bench-top models, and CRCD [Oh et al., 2024] uses ex-vivo pig-liver pseudo-cholecystectomy. KASA preserves real in-vivo appearance and actions, but its legacy videos lack logs; HSA/DPT therefore recover 9D actions offline. For KVLR, kinematics is only the conditioning input: given logged or reconstructed 9D states, HSA/DPT are not needed. CRCD then supplies complementary synchronized-log validation.

DPT against FK in CRCD [Oh et al., 2024]. This external test uses the first eight eligible procedure IDs in lexicographic order, selected before evaluation; eligibility requires valid video, kinematics, calibration, and synchronization. The reproducible rule avoids performance-based selection, covers six of CRCD's seven surgeons (85.7%), and yields ∼283,000\sim 283{,}000 synchronized frames at 30 Hz. DPT meets a fixed reliable-comparison criterion—CAD/observed-mask Dice ≥ 0.85—on ∼236,000\sim 236{,}000 frames (83.4%), with 5.31 mm translation and 8.60° SO(3) rotation error against FK on those frames. The observed masks are official CRCD v2 annotations and are used only as a post-hoc quality-control gate. The ∼47,000\sim 47{,}000 failures (16.6%) are counted separately by occlusion, blur, reflection, or boundary truncation. We align da Vinci Research Kit (dVRK) logs with stereo-endoscopic timestamps and use one fixed calibrated robot-to-left-camera transform, with no trajectory-specific registration or scale fitting.

KVLR generation with real dVRK trajectories. We convert synchronized dVRK FK states to the same 9D action representation at 30 Hz. KVLR receives the first real CRCD frame, a text description, and the real action sequence, without CRCD fine-tuning, DPT, or human correction. Generated videos are compared with the corresponding real CRCD videos:

Method / conditioning on CRCD [Oh et al., 2024] CD ↓ TI ↑ AF ↓ Trans. recovery (mm) ↓ Rot. recovery (°) ↓
KVLR + real dVRK kinematics 93.60 0.84 5.67 7.18 9.96
KVLR + DPT-reconstructed kinematics 98.85 0.81 6.34 8.52 10.88
Cosmos-H-Surgical (text/reference only) 152.34 0.51 14.82 14.25 22.67
SurgSora† 128.56 0.68 9.45 11.38 19.54
OpenSora-2.0† 135.21 0.63 10.82 12.54 20.83

All methods are evaluated on the same eight procedures, receive the same first frame/text, and use no CRCD fine-tuning. SurgSora† and OpenSora-2.0† receive dense fields rendered from the same FK/CAD/intrinsics; Cosmos-H-Surgical uses its text/reference interface. Recovery uses one KASA-trained TimeSformer-S frozen across sources, and its recovered actions are compared with the synchronized CRCD FK trajectories. Thus absolute CRCD recovery mixes evaluator domain gap and generation quality; the shared-evaluator ranking is primary (on real held-out KASA, it obtains 4.58 mm/6.92°).

Together, these tests evaluate DPT against synchronized FK on the explicit 83.4% success subset and KVLR with true robot trajectories; logged states bypass HSA/DPT. We will cite JIGSAWS and CRCD fully and move the compact comparison to Sec. 4.2.

3. Metric scale and application to an unseen legacy video

Metric scale comes from known-size CAD, calibrated intrinsics, and visible-frame wrist-keypoint Perspective-n-Point (PnP) initialization, not unconstrained monocular depth. Fig. 4 shows the CAD/PnP initialization. An unseen video requires compatible CAD/articulation, intrinsics, and one such initialization; tracking retains that scale and can reinitialize from memory. We will state this in revised Sec. 3 and add FK-referenced metric validation in revised Sec. 4.2.

4. Generation horizon

Without paired kinematics, KVLR can generate a longer reference/text-conditioned video, and its output length is not tied to an action sequence. In this mode the action branch is omitted, so the frames are not explicitly action-controlled. We verified reference/text-only generation beyond KASA's maximum paired horizon as a capability check, not action-faithfulness evidence. In the evaluated action-conditioned setting, KVLR produces one output frame per supplied state, x1:T=F(Iref,y,a1:T)x_{1:T}=F(I^{ref},y,a_{1:T}). KASA evaluates complete annotated actions of 55–235 frames, so action-faithfulness claims apply to that grounded horizon.

5. Kinematics in the "what-if" examples

Fig. 6(a) fixes the reference scene and supplies alternative kinematic trajectory variants derived from expert actions. This isolates action sensitivity: changing only kinematics produces corresponding visual evolution. It also illustrates data diversification: on a calibrated new robotic platform, recorded or teleoperated trajectories can generate multiple action-aligned videos from one scene. Trajectories are inputs; the experiment tests their faithful visual realization. We will revise the caption to state both motivations explicitly.

6. GraSP setting

This is cross-dataset evaluation without fine-tuning under familiar suturing actions, not unseen categories. We use compatible GraSP knotting and needle-puncture segments; the shift covers tissue, lighting, viewpoint, acquisition, and annotations. Its purpose is external evaluation: beyond the first frame, the existing GraSP video is used only to recover the test action and provide a paired reference, and KVLR does not receive it as generation input. We will replace “zero-shot” and name the subset in Sec. 4.2 and Table 4.

7. CD and visual action recovery

CD measures generated-tool/action-target spatial agreement; TI mask persistence; and AF relative area flicker. These image-space metrics apply uniformly even when a generator has no kinematic output. As shown in Table 5, the paper also reports independent centerline, endpoint, and motion-direction measurements. We further use one visual-to-action regressor trained only on real KASA and frozen across sources:

Video source Recovered trans. MAE (mm) ↓ Recovered rot. MAE (°) ↓ Recovered gripper-state acc. (%) ↑
Cosmos-H-Surgical* 11.24 18.35 62.7
SurgSora† 9.81 16.42 67.3
OpenSora-2.0† 10.56 17.15 64.8
KVLR-fast 6.15 9.24 82.5
KVLR 5.37 7.81 86.4

On held-out real KASA it obtains 4.58 mm, 6.92°, and 88.1%. These are recovered visual-action measurements; CRCD separately tests generation conditioned on synchronized robot trajectories.

8. Complete actions, split, and unified action recognition

Full actions or partial clips? Yes, KVLR generates full actions. As described in Sec. 3, each sample follows SAR-RARP's transition-to-transition definition: one complete knotting, needle-grasping, or needle-puncture action (55–235 frames). The 85/15 split is RARP-operation-disjoint; all categories occur in both partitions, and one KVLR model covers all categories.

One action model or three category-specific models? One unified model. We train one class-balanced three-way recognizer on real KASA under three seeds. Within each seed, one frozen checkpoint/preprocessing classifies all generated sources; the table reports the mean.

Video source Macro-F1 ↑ Bal. acc. ↑ Knotting F1 ↑ Grasping F1 ↑ Puncture F1 ↑
Real held-out KASA 0.78 0.80 0.70 0.81 0.83
Cosmos-H-Surgical* 0.41 0.44 0.23 0.45 0.54
KVLR-fast 0.67 0.69 0.55 0.70 0.76
KVLR 0.72 0.74 0.62 0.76 0.79

KVLR reaches 0.72 macro-F1, near 0.78 on held-out real KASA and substantially above Cosmos-H-Surgical* at 0.41, indicating action-relevant content closer to real video. Visual-to-action recovery above adds continuous trajectory-level evidence.

Authors · CommentOpenReview ↗

Dear Reviewer cvqQ,

Thank you again for your detailed and constructive review. With the discussion period nearing its end, we would like to gently follow up and invite you to review our rebuttal when convenient.

We directly address your main concern regarding self-containedness by specifying how the essential definitions and evaluation protocols will be consolidated into the unchanged nine-page main paper. We also provide the requested validation with synchronized dVRK trajectories on CRCD, together with clarifications and additional evidence on metric scale, generation horizon, full-action generation and recognition, and visual action recovery.

We would be grateful to know whether our response addresses your concerns. If anything remains unclear, we would be happy to provide a concise clarification before the discussion closes.

Thank you for your time.

Reviewer MxKBOpenReview ↗
Rating
6/6
Confidence
4/5
Quality
4/4
Clarity
3/4
Significance
4/4
Originality
4/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper presents a novel approach to surgical video generation conditioned on robot kinematic actions. The core of the method is a two-stage framework that first projects robot kinematic information into image-space, including the semantic, depth, rotation, velocity, and acceleration components. Second, a novel hierarchical routing mechanism is introduced to dynamically fuse the projected kinematic modalities with the video generation process, which is also conditioned on the previous video frame and text description. This approach shows significant improvements over existing methods in terms of video quality and computational efficiency, with a 26.6% CD improvement over Cosmos-H and a 47.1% latency reduction for the model's "fast" variation. Additionally, the paper provides a kinematic articulated surgical action dataset (KASA), using human-in-the-loop segmentation and differentiable rendering of CAD-based robotic models to obtain accurate kinematic information. This allows for skill-specific evaluation of the video generation model. The paper is well-written, and the proposed method is clearly described, with comprehensive experimental results demonstrating its effectiveness.

Strengths and weaknesses

Strengths

  • Although action-conditioned video generation has been explored in prior work (eg [39]), this paper represents a significant step forward in terms of detailed controllability, with the kinematic visual field encoding complete information about the robot state in image-space, made usable by the hierarchical routing mechanism.
  • The paper fills a critical gap in the literature by providing a kinematic articulated surgical action dataset (KASA), evaluating surgical video generation models not just in terms of perceptual quality (CD, FID, etc.) but also in terms of skill-specific evaluation, which is crucial for surgical applications.
  • Against relevant baselines, including text-conditioned generation models, raw action-conditioned models, and visual action conditioned models, the proposed method demonstrates significant improvements in both video quality and computational efficiency, with a 26.6% CD improvement over Cosmos-H and a 47.1% latency reduction for the model's "fast" variation.
  • The KASA evaluation enables surgical skill-specific evaluation of the generated videos in terms of perceptual quality, highlighting areas where quality could be improved and demonstrating the proposed method's advantage over SOTA methods, especially for knotting and needle puncture.
  • The ablation study demonstrates the importance of each component, including the visual kinematic field and the hierarchical routing mechanism, in achieving the reported performance improvements.
  • Downstream evaluation demonstrates that synthetic data using the proposed KVLR improves tool segmentation performance.

Weaknesses

Major weaknesses preventing acceptance: None

Minor weaknesses:

Downstream utility is limited to tool segmentation, the only downstream task evaluated in the paper. While this is a reasonable starting point, it does not fully demonstrate the utility of the proposed method for surgical video generation, which is intended to support a wide range of downstream tasks, including surgical skill assessment, training, and decision support. Tool segmentation is by far the easiest downstream task to evaluate and the least likely to benefit from additional data, since realistic synthetic data for tool segmentation could be readily generated using photorealistic rendering of CAD models. Expanding on this aspect, either in experiments or in a more detailed discussion, would strengthen the paper and provide a more comprehensive understanding of the proposed method's impact on surgical video generation.

No comparison to SAW [39], the most methodologically similar approach. Although SAW is not yet publicly available, it would be helpful to include a discussion of how the proposed method compares to SAW in terms of methodology and expected performance. In particular, SAW's use of depth, tip trajectories, and text conditioning is similar to the proposed method, and a discussion of whether these elements can be considered a subset of the proposed method would be useful.

Justification

Although the lack of downstream evaluation beyond tool segmentation is a significant limitation in my view, the paper makes a strong contribution to the field of surgical video generation. The proposed method demonstrates significant improvements over existing methods in terms of video quality and computational efficiency, and the KASA dataset provides a valuable resource for evaluating surgical video generation models. Exhaustive experimental results, including ablation studies and skill-specific evaluation, support the claims made in the paper, and while I would have liked to see a more comprehensive evaluation of downstream utility, the demonstrated benefits for tool segmentation are a strong indication of the generated data's utility. The lack of comparison to SAW is a minor weakness and acceptable given the unavailability of the SAW method, but a discussion of the similarities and differences would have been helpful. Overall, the paper is well-written, and the proposed method is clearly described, with comprehensive experimental results demonstrating its effectiveness.

Questions

None

Limitations

Downstream utility evaluation limited to tool segmentation, as described in the weaknesses section.

Formatting concerns

None

1 comment
Authors · RebuttalOpenReview ↗
Rebuttal

Thank you for the constructive comments. We address the two points below.

1. Downstream utility beyond tool segmentation

The most immediate evaluated use of KVLR is action-conditioned data augmentation. Its control interface can generate trajectory-specific visual variations under a fixed surgical context, while action recognition is a foundational component of skill assessment, surgical training feedback, and context-aware assistance. The submitted experiment in Supp. Sec. F.1 and Table 12 evaluates segmentation on held-out real KASA data: Real + KVLR improves SegFormer-B1 over Real only from 75.6 to 79.6 part mIoU, 91.3 to 93.4 tool IoU, 77.8 to 81.0 boundary F-score, and 84.5 to 87.5 temporal consistency.

As suggested by the reviewer, we further evaluate complete-action recognition using one unified class-balanced three-way recognizer averaged over three training seeds. For generated-video evaluation, the recognizer is trained only on real KASA training actions and frozen across generated sources. For augmentation, synthetic videos come only from the training partition; Cosmos-H-Surgical* and KVLR use the same synthetic sample count and class distribution, and all models are evaluated on the same held-out real operations.

Setting Macro-F1 ↑ Bal. acc. ↑ Knotting F1 ↑ Grasping F1 ↑ Puncture F1 ↑
Real only → real validation 0.78 0.80 0.70 0.81 0.83
Frozen recognizer → Cosmos-H-Surgical* 0.41 0.44 0.23 0.45 0.54
Frozen recognizer → KVLR 0.72 0.74 0.62 0.76 0.79
Real + Cosmos-H-Surgical* → real validation 0.79 0.81 0.71 0.82 0.84
Real + KVLR → real validation 0.84 0.85 0.79 0.86 0.88

The new recognition experiment extends the submitted segmentation result to action understanding: adding KVLR-generated training actions improves held-out real macro-F1 from 0.78 to 0.84. We will include these results in Sec. 4.2, with the matched protocol and per-class metrics in Supp. Sec. F.7.

2. Relation to SAW [39]

We will expand the current brief discussion of this closely related work. SAW [39] conditions on a reference scene, language, a tissue-affordance mask, and 2D tool-tip trajectories, while using depth as a training regularizer rather than an inference input. Its 2D tip control is related to the image-plane trajectory induced by KVLR's 3D wrist pose and articulation. The conditioning sets are different: KVLR represents 3D translation, 3D orientation, and articulated joint/gripper states, whereas SAW's tissue-affordance mask provides interaction information not explicitly represented by KVLR. The empirical settings are also different. SAW studies scalable laparoscopic synthesis, rare-action augmentation, and simulator-trajectory rendering; KVLR studies articulated 3D control fidelity, routing across physical modalities and motion scales, and efficient robotic suturing generation.

As the datasets, action taxonomies, and inputs differ, cross-paper numbers are not directly comparable. We will therefore expand the comparison in Sec. 1 and Supp. Sec. B.1, covering conditioning inputs, control granularity, tissue affordance, efficiency, and downstream evaluation.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Missing a submission?

Loading the discussion…