potentialpaper

MedVTok: A General-Purpose Medical Visual Tokenizer

Chenglong Ma, Yuanfeng Ji, Junzhi Ning, Jiyao Liu, Yujie Wei, Shaohao Rui, Chaoyang Zhang, Wenjie Li, Wenhao Tang, Cheng Tang, Wei Li, Shujian Gao, Yujie Zhang, Ying Chen, Zilong Li, Zongyuan Ge, Diping Song, Jin Ye, Ming Hu, Junjun He, Hongming Shan

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

TL;DR. MedVTok is a general-purpose medical visual tokenizer that unifies 2D/3D multimodal images into a shared token space and achieves state-of-the-art performance across diverse tasks.

Abstract. Multimodal medical AI requires a common visual interface that integrates heterogeneous imaging evidence for patient condition modeling. However, existing medical visual tokenizers are often tied to a specific dimension and imaging modality, forcing multimodal systems to rely on fragmented and poorly reusable representations. We introduce MedVTok, a general-purpose visual tokenizer that maps 2D images and 3D volumes from diverse imaging modalities into a unified token space. Building such a tokenizer poses two key challenges: preserving anatomical structure across dimensions and capturing clinical semantics across modalities. To this end, MedVTok introduces (i) slice differential regularization, which explicitly models inter-slice anatomical coherence missing in previous per-pixel/per-voxel supervision, and (ii) multi-expert representation alignment, which integrates knowledge from multiple medical expert encoders while retaining modality-specific complementary knowledge. Trained on 28M images and 70K volumes across 9 imaging modalities, MedVTok supports classification, retrieval, segmentation, synthesis, visual question answering, and medical report generation through a single tokenizer. Across 24 benchmarks, MedVTok achieves state-of-the-art performance, demonstrating a scalable token interface that unifies medical image dimension, modality, and task usage. Project page: https://masaaki-75.github.io/medvtok

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
16 Apr 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:46 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

This paper proposes a general-purpose medical visual tokenizer for multimodal medical AI, capable of encoding both 2D images and 3D volumes into a unified token space. The proposed method, MedVTok, introduces (1) slice differential regularization to model inter-slice volumetric continuity, and (2) multi-expert representation alignment, which uses multiple modality-specific expert encoders to provide semantic supervision. This design learns a shared representation space while retaining complementary semantics in individual expert spaces. Extensive comparisons with SOTA methods, along with evaluations on downstream tasks demonstrate the effectiveness of the proposed method.

All reviewers agreed that that problem is important, the experimental results are convincing, and the proposed method is effective. With additional experimental results and further clarification, the rebuttal addressed most reviewers’ concerns. Given the concerns above, my recommendation is to accept this paper.

Final justification

Overeall, all reviewers recommend acceptance: two strong accept and one borderline accept. I also concur with the Reviewer yovp that the methodological novelty is somehow limited, yielding relatively modest improvements compared with related counterparts. Hence, I finally recommend acceptance as a poster.

Area Chair n21z · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

This paper proposes a general-purpose medical visual tokenizer for multimodal medical AI, capable of encoding both 2D images and 3D volumes into a unified token space. The proposed method, MedVTok, introduces (1) slice differential regularization to model inter-slice volumetric continuity, and (2) multi-expert representation alignment, which uses multiple modality-specific expert encoders to provide semantic supervision. This design learns a shared representation space while retaining complementary semantics in individual expert spaces. Extensive comparisons with SOTA methods, along with evaluations on downstream tasks demonstrate the effectiveness of the proposed method.

All reviewers agreed that that problem is important, the experimental results are convincing, and the proposed method is effective. With additional experimental results and further clarification, the rebuttal addressed most reviewers’ concerns. Given the concerns above, my recommendation is to accept this paper.

Final justification

Overeall, all reviewers recommend acceptance: two strong accept and one borderline accept. I also concur with the Reviewer yovp that the methodological novelty is somehow limited, yielding relatively modest improvements compared with related counterparts. Hence, I finally recommend acceptance as a poster.

1 comment
Authors · CommentOpenReview ↗

Rebuttal Summary

We sincerely thank the metareviewer and all reviewers for the careful evaluation and constructive guidance. Among the concerns and questions raised, we first address issues highlighted in the metareview:

  1. Stronger controlled comparisons. Under matched experimental settings, MedVTok consistently outperforms representative tokenizers. This shows that its gains are not explained solely by data scale, initialization, or compute.
  2. Direct 3D downstream validation. We added frozen-tokenizer 3D segmentation and cross-dataset transfer experiments. MedVTok performs best among compared methods, demonstrating that its tokens preserve volumetric anatomical information and transfer effectively to voxel-level prediction.
  3. More rigorous analysis of SliDR and MERA. Controlled comparisons show that SliDR is more effective than standard gradient, TV, and Laplacian regularization for preserving inter-slice structure. We also clarify that MERA is designed not for per-sample expert fusion, but for learning a shared semantic space while retaining modality-specific knowledge. Ablations support the contribution of both multi-expert supervision and expert-space preservation.

Beyond these, our rebuttal addresses other concerns through experiments and clarifications on modality-expert comparisons, multimodal training, downstream adaptation, and OOD tests, verifying MedVTok's effectiveness.

We have also clarified MedVTok’s distinction from prior work. Existing tokenizers do not address the two central challenges in learning from heterogeneous medical imaging: (1) preserving structural fidelity across data dimensions, and (2) retaining modality-specific semantics within a shared representation space. MedVTok addresses both, building a single reusable interface for multimodal medical imaging data.

We hope these clarifications and results resolve the concerns.

Reviewer oCDHOpenReview ↗
Rating
6/6
Confidence
4/5
Quality
4/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

MedVTok proposes a general-purpose medical visual tokenizer for multimodal medical AI, aiming to encode heterogeneous 2D medical images and 3D volumetric scans from diverse imaging modalities into a unified token space. To address the dimensional and semantic heterogeneity of medical imaging, the method adopts a unified 3D patchification scheme for both 2D and 3D inputs, and introduces Slice Differential Regularization to preserve inter-slice anatomical continuity during volumetric reconstruction. In addition, it proposes Multi-Expert Representation Alignment, which leverages multiple modality-specific expert encoders to provide semantic supervision, aligning representations in a shared space while retaining complementary knowledge from individual expert spaces. Trained on large-scale multimodal medical imaging data, MedVTok is evaluated as a frozen tokenizer across a broad range of downstream tasks, including reconstruction, classification, retrieval, segmentation, image synthesis, visual question answering, and 3D medical report generation. The results demonstrate that MedVTok provides a unified and transferable token interface for both structural fidelity and clinical semantic modeling across diverse medical imaging tasks.

Strengths and weaknesses

Strengths:

  1. The paper proposes a single tokenizer that can encode both 2D medical images and 3D volumetric scans into a shared token space, reducing the need for modality- or dimension-specific visual front ends.

  2. MedVTok is designed to support a wide range of common medical imaging modalities, including CT, MRI, X-ray, OCT, fundus imaging, pathology, dermoscopy, endoscopy, and ultrasound.

  3. The method leverages multiple modality-specific expert encoders to provide richer clinical semantic supervision than single-expert alignment, while retaining complementary modality-specific knowledge.

  4. A single frozen MedVTok tokenizer is shown to support diverse downstream tasks, including reconstruction, classification, retrieval, segmentation, image synthesis, visual question answering, and medical report generation.

Weaknesses:

  1. The method requires large-scale pretraining on tens of millions of 2D images and tens of thousands of 3D volumes, together with multi-expert semantic alignment. This makes the overall training pipeline computationally expensive.

  2. Although the paper claims to support both 2D images and 3D volumes, the empirical evaluation of 3D capability is relatively limited. Most downstream tasks are evaluated primarily on 2D benchmarks, while 3D volume experiments are mainly restricted to reconstruction and report generation.

  3. MERA integrates knowledge from multiple expert encoders into a shared token space, which is a promising direction. However, different experts may encode heterogeneous or even conflicting information: some may emphasize low-level anatomical structure, while others may focus more on high-level semantic categories. Since the native feature spaces of different modality-specific experts may not be fully compatible, it remains unclear how robustly MERA handles potential conflicts or negative transfer among experts.

  4. While the paper demonstrates strong transfer performance on medical imaging benchmarks excluded from tokenizer pretraining, most downstream evaluations still rely on train/test splits within the same benchmark. As a result, the experiments do not fully validate MedVTok’s robustness under more challenging out-of-distribution settings, such as cross-dataset, cross-institution, or cross-scanner/protocol generalization.

Questions

Please see my weaknesses.

Limitations

yes

Final justification

The authors’ rebuttal has fully addressed all of my concerns. In particular, the additional 3D segmentation, cross-dataset transfer, OOD evaluation, and MERA analyses substantially strengthen the empirical support for the paper. I therefore raise my rating from 5 to 6.

Formatting concerns

No

3 comments
Authors · RebuttalOpenReview ↗
Rebuttal

Thank you for your constructive feedback and focused questions. Below we address your concerns regarding training costs, 3D evaluation, expert compatibility, and OOD generalization.


W1. (About training cost) The method requires large-scale pretraining on tens of millions of 2D images and tens of thousands of 3D volumes, together with multi-expert semantic alignment. This makes the overall training pipeline computationally expensive.

Thank you for raising this. We agree that pretraining MedVTok is resource-intensive. However, this one-time cost should be contextualized within its intended use: MedVTok is a reusable foundational tokenizer designed to be trained once and reused broadly, not a task-specific model requiring frequent retraining.

1. Pretraining scale is standard for foundation models Broad foundation models require massive, diverse corpora to cover underlying data distributions. MedVTok's training scale and compute align with, or are significantly lower than, comparable models:

Model Pretraining data scale Reported training compute
AToken Billion-scale images and million-scale videos 256 H100 for 22 days (138K GPU-hours)
MedSigLIP 33M medical image–text pairs Not reported
MedITok 30M images and 2M image–caption pairs 8 H100 for 4 days (768 GPU-hours)
MedVTok 28M images and 70K volumes 16 H200 GPUs for 59.25 hours (948 GPU-hours)

(Note that there are data source overlap between 28M images and 70K volumes in MedVTok)

2. MERA is computationally efficient

"Multi-expert alignment" does not require loading all expert models during training:

  • We run each expert offline once to cache features.
  • The training loop contains only MedVTok, lightweight modality-specific projectors, and losses.
  • No expert weights or repeated forward passes are used during MedVTok's training or inference.

3. Downstream usage is lightweight For end-users, the recurring cost is minimal. We measured complete reconstruction inference (FP16, batch size 1) on a single consumer-grade RTX 4090 GPU at 512² resolution. MedVTok matches the efficiency of existing tokenizers:

Models Params. (M) 512² GFLOPs Peak mem. (GiB) Throughput (img/s)
MedITok 696.65 3072.22 4.318 21.77
AToken 845.74 1965.42 4.837 13.97
MedVTok 831.83 1959.50 4.772 14.40

W2. (About direct 3D downstream evaluation) Although the paper claims to support both 2D images and 3D volumes, the empirical evaluation of 3D capability is relatively limited. Most downstream tasks are evaluated primarily on 2D benchmarks, while 3D volume experiments are mainly restricted to reconstruction and report generation.

Thank you for this suggestion! To strengthen our 3D evaluation, we have added direct 3D dense segmentation results on two datasets excluded from tokenizer pretraining: AMOS-MM (CT) and MRISegmenter (MRI).

Setup: For all methods, the tokenizer is frozen, and only a lightweight 3D convolutional head is trained on the volumetric features to predict segmentation masks.

AMOS-MM CT Dice (%).

Model Overall Spleen Kidney Liver Pancreas Adrenal Gallbl. Esoph. Stomach Duod. Major vessels
PUMIT 28.67 63.68 ± 1.58 48.94 ± 1.96 76.63 ± 2.68 13.42 ± 1.99 16.50 ± 1.30 18.78 ± 2.21 16.29 ± 1.02 4.96 ± 0.76 3.37 ± 1.73 24.14 ± 1.82
MedVAE-3D 29.71 42.94 ± 2.64 45.95 ± 2.36 73.73 ± 2.23 23.51 ± 2.60 12.74 ± 1.10 16.33 ± 2.99 18.59 ± 2.98 3.71 ± 0.76 10.44 ± 2.00 49.19 ± 2.05
AToken 36.89 55.76 ± 2.46 59.56 ± 2.44 80.50 ± 1.72 31.64 ± 2.72 20.44 ± 1.47 14.93 ± 1.82 15.14 ± 1.80 34.63 ± 3.53 15.04 ± 1.46 41.22 ± 1.65
MedVTok 50.13 70.61 ± 2.30 74.93 ± 1.74 86.31 ± 1.00 41.90 ± 2.36 23.64 ± 1.76 39.69 ± 4.57 19.04 ± 2.68 62.15 ± 3.87 30.48 ± 2.71 52.53 ± 1.37

MRISegmenter MRI Dice (%).

Model Overall Spleen Kidney Liver Pancreas Adrenal Gallbl. Esoph. Stomach Duod. Major vessels
PUMIT 44.57 ± 0.76 40.83 ± 2.12 81.60 ± 1.29 58.11 ± 1.32 49.43 ± 2.22 24.00 ± 1.43 24.20 ± 3.46 48.05 ± 1.82 40.66 ± 2.03 14.82 ± 1.64 64.00 ± 1.28
MedVAE-3D 43.70 ± 0.80 40.68 ± 2.14 77.46 ± 1.77 59.11 ± 1.23 43.98 ± 2.08 21.69 ± 1.87 23.31 ± 3.27 39.28 ± 2.26 46.67 ± 2.05 16.41 ± 1.62 68.46 ± 1.18
AToken 54.63 ± 0.68 63.28 ± 2.71 83.96 ± 0.67 85.71 ± 0.94 49.23 ± 1.92 25.63 ± 1.49 32.85 ± 3.68 44.92 ± 1.79 52.08 ± 1.30 40.11 ± 1.75 68.52 ± 0.91
MedVTok 57.20 ± 0.76 70.60 ± 2.85 86.48 ± 0.95 85.83 ± 0.70 49.49 ± 2.71 23.16 ± 1.64 34.94 ± 3.76 52.78 ± 1.61 59.89 ± 2.30 39.23 ± 1.80 69.56 ± 0.93

These results prove that MedVTok's frozen representations effectively transfer to dense voxel-level prediction tasks. We will add these tables to the revised manuscript.


W3. (About expert compatibility in MERA) MERA integrates knowledge from multiple expert encoders into a shared token space, which is a promising direction... Since the native feature spaces of different modality-specific experts may not be fully compatible, it remains unclear how robustly MERA handles potential conflicts or negative transfer among experts.

Thanks for raising this question. MERA is designed to avoid cross-expert interference:

  1. Expert Selection: We ensure that expert models in MERA are trained in the similar paradigm, i.e., CLIP-style. There are other good models (DINO-style, MAE-style) but they are not included in our expert pool to avoid potential conflicts.
  2. Modality-Specific Routing: A sample is routed only to the expert corresponding to its imaging modality. There is no same-sample competition among different teachers.
  3. Independent Projectors: Each expert features a dedicated projector into the shared space and a corresponding backprojector. Because these are independent, heterogeneous native dimensions do not conflict.
  4. Shared Tokenizer Supervision: The expert-space loss propagates gradients through the backprojector directly into the shared MedVTok representations.

Our matched ablation (Fig. 5) confirms that this multi-expert approach yields steady improvements:

Alignment Cls. Acc. (%) Seg. Dice (%)
Single expert 71.30 66.91
Multiple experts, shared loss only 72.38 69.58
Full MERA (+ expert-space loss) 73.91 69.97

W4. (About downstream OOD evaluation) While the paper demonstrates strong transfer performance on medical imaging benchmarks excluded from tokenizer pretraining, most downstream evaluations still rely on train/test splits within the same benchmark. As a result, the experiments do not fully validate MedVTok’s robustness under more challenging out-of-distribution settings, such as cross-dataset, cross-institution, or cross-scanner/protocol generalization.

Thank you for the thoughtful comment! Per your suggestion, we show two additional experiments along complementary OOD axes.

(1) Cross-dataset 3D segmentation.

We evaluated the frozen-tokenizer models trained on MRISegmenter (from W2) directly on the MRI subset of AMOS-MM, with zero target-domain training or tuning. Dice scores are computed over the ten shared anatomical labels:

Model MRISegmenter source AMOS-MM-MR direct transfer Absolute drop
PUMIT 44.57 ± 0.76 31.44 ± 1.52 13.14
MedVAE-3D 43.70 ± 0.80 33.52 ± 3.82 10.18
AToken 54.63 ± 0.68 44.39 ± 1.75 10.24
MedVTok 57.20 ± 0.76 47.24 ± 1.47 9.95

MedVTok achieves the highest direct-transfer Dice, showing robust cross-dataset generalization.

(2) Transfer to an unseen modality.

We evaluated frozen representations on PBC, a hematology microscopy classification dataset. Neither this dataset nor the microscopy modality was seen during MedVTok pretraining, representing a strict OOD shift.

Models kNN Acc. (%) Linear-probe Acc. (%)
MedVAE 40.47 ± 0.15 79.47 ± 1.35
PUMIT 36.98 ± 0.55 93.25 ± 0.84
MedITok 90.73 ± 0.62 94.62 ± 0.76
AToken 92.00 ± 2.07 92.84 ± 0.87
MedVTok 94.78 ± 1.81 96.84 ± 0.59

MedVTok ranks first under both non-parametric kNN and linear probing setups, exceeding the strongest baseline. We will include both OOD experiments in the revised manuscript.

Reviewer oCDH · CommentOpenReview ↗

The authors’ rebuttal has fully addressed all of my concerns. In particular, the additional 3D segmentation, cross-dataset transfer, OOD evaluation, and MERA analyses substantially strengthen the empirical support for the paper. I therefore raise my rating from 5 to 6.

Authors · CommentOpenReview ↗

Thank you very much for the thoughtful review and positive feedback! We are happy that the additional clarifications have addressed your concerns. Your comments have helped us further improve the manuscript, and we truly appreciate your time and careful consideration of our work.

Reviewer qrJPOpenReview ↗
Rating
6/6
Confidence
4/5
Quality
4/4
Clarity
4/4
Significance
4/4
Originality
4/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

In this paper, the authors aimed to train a general-purpose medical visual tokenizer called MedVTok. It is trained to be able to tokenize 9 different modalities of medical imaging, spanning across 2D and 3D. MedVTok first tokenizes the 2D/3D imaging into patches, then encode it with a transformer encoder. The encoded tokens are then decoded by a transformer decoder to reconstruct the original input, and the reconstruction loss is the main training objective. In addition, MedVTok deploys Multi-Expert Representation alignment to align each modality's encoding with modality expert models. Two additional regularization terms are applied: KL divergence between encoded tokens and Gaussian, and slice differential regularizations. The trained MedVTok encoder is then used as a generalist token encoder for many downstream task evaluations, including autoencoding fidelity, image classification and retrieval, segmentation, synthesis, VQA and report generation, and MedVTok achieved top performance against baselines across all tasks.

Strengths and weaknesses

Strengths:

  1. The introduced a method for training general-purpose medical visual tokenizer, which is able to tokenize and encode medical imaging across a wide variety of 2D and 3D modalities. The proposed visual tokenizer training method is novel and sound, and achieved top performance across all tasks.

  2. The evaluation is extremely comprehensive, covering many different tasks (reconstruction, classification, retrieval, segmentation, VQA, report generation) with several different benchmarks from different modalities used for each task, and MedVTok excelled in all of them, suggesting strong generalizability across tasks.

  3. The training and evaluation utilizes publically available data, and the authors curated them into a large scale imaging corpus that future researchers may use. In. addition, the authors built 24 benchmarks for comprehensive evaluation, which helps standardize evaluation for general-purpose medical imaging models.

  4. The paper is well-written and easy to follow.

Weakness:

No major weaknesses. One minor suggestion: It may also be good to include domain-expert performance in each evaluated task as a reference (MedVTok does not have to beat them, but it may be beneficial to see where MedVTok currently stands against the expert tokenizer models within each modality)

Questions

Suggestions for additional exploration in future work:

  1. whether MedVTok's performance benefits from multimodal training, i.e. if we train MedVTok in the exact same way but using fewer modalities, will its performance on downstream tasks on the trained modalities be better or worse?

  2. given an unseen modality, how can we adapt/finetune a trained MedVTok model to this new modality, and does the finetuned MedVTok model perform better than other generalist tokenizer baselines finetuned in the same way?

Limitations

Yes

Final justification

I didn't have much concerns with this paper to begin with, so my score remains very positive.

Formatting concerns

N/A

3 comments
Authors · RebuttalOpenReview ↗
Rebuttal

Thank you for your constructive feedback and insightful questions. Below, we provide the requested modality-expert comparisons, analyze the effects of joint multimodal training, and demonstrate MedVTok's adaptability to unseen modalities.


W1. (About modality-expert reference performance) It may also be good to include domain-expert performance in each evaluated task as a reference (MedVTok does not have to beat them, but it may be beneficial to see where MedVTok currently stands against the expert tokenizer models within each modality)

Thank you for this helpful comment.

Per your suggestion, we showed below the comparison of MedVTok and the expert models used in MERA: RetCLIP (CFP), DermLIP (dermoscopy), PeskaVLP (endoscopy), and Conch (pathology), alongside the broad-domain MedImageInsight (MII) encoder.

1. Classification Acc. (%):

Models CFP CT Derm. Endo. MRI OCT Path. US X-ray
RetCLIP 91.95 ± 1.05 -- -- -- -- -- -- -- --
DermLIP -- -- 79.72 ± 0.66 -- -- -- -- -- --
PeskaVLP -- -- -- 48.64 ± 2.29 -- -- -- -- --
Conch -- -- -- -- -- -- 93.08 ± 2.44 -- --
MedImageInsight 75.64 ± 2.12 75.32 ± 2.83 85.87 ± 0.38 44.65 ± 0.74 95.47 ± 0.29 90.79 ± 1.18 71.79 ± 2.92 50.18 ± 2.67 96.21 ± 0.83
MedVTok 90.54 ± 1.05 87.03 ± 1.64 75.27 ± 0.99 51.00 ± 1.85 95.03 ± 0.52 94.00 ± 1.18 78.97 ± 1.65 52.92 ± 1.68 97.22 ± 0.61

2. Segmentation Dice (%):

Models CFP CT Derm. Endo. MRI Path. US X-ray
RetCLIP 92.46 ± 1.69 -- -- -- -- -- -- --
DermLIP -- -- 89.05 ± 1.86 -- -- -- -- --
PeskaVLP -- -- -- 65.06 ± 1.51 -- -- -- --
Conch -- -- -- -- -- 83.77 ± 1.39 -- --
MedImageInsights 92.34 ± 1.39 25.60 ± 1.35 85.45 ± 2.10 66.96 ± 1.32 55.81 ± 1.31 42.93 ± 1.86 95.80 ± 2.07 50.16 ± 1.48
MedVTok 97.44 ± 1.59 42.91 ± 1.80 90.25 ± 0.77 72.52 ± 1.15 69.62 ± 1.07 77.74 ± 1.56 96.91 ± 1.80 61.13 ± 1.17

MedVTok remains highly competitive as a unified interface. It outperforms the broad-domain MedImageInsight on 7 of 9 modalities for classification and on all 8 for segmentation. Against dedicated experts, MedVTok exceeds PeskaVLP, closely matches RetCLIP, and trails only DermLIP and Conch on their native domains. Notably, MedVTok exceeds three of the four experts in dense prediction, demonstrating its ability to retain crucial spatial details that global expert representations often discard. We will include these results in the revised manuscript.


Q1. (About multimodal training) Whether MedVTok's performance benefits from multimodal training, i.e. if we train MedVTok in the exact same way but using fewer modalities, will its performance on downstream tasks on the trained modalities be better or worse?

Thank you for this insightful question. To test whether joint multimodal training causes positive or negative transfer, we ran a controlled, leave-one-out experiment under a fixed 2M-image budget. We trained three MedVTok variants: all nine modalities, dermoscopy excluded, and pathology excluded. To maintain the data budget, samples from the excluded modality were replaced by samples from the remaining modalities.

1. Effect of Excluding Dermoscopy:

Excluded modality PSNR (dermoscopy) PSNR (other) Acc. (dermoscopy) Acc. (other) Dice (dermoscopy) Dice (other)
None 40.05 39.67 69.18 72.01 88.74 70.99
Dermoscopy 39.78 39.52 67.72 72.03 85.83 70.92
Δ (%) −0.70% −0.38% −2.10% +0.03% −3.27% −0.09%

2. Effect of excluding Pathology:

Excluded modality PSNR (pathology) PSNR (other) Acc. (pathology) Acc. (other) Dice (pathology) Dice (other)
None 30.13 40.91 73.64 71.45 75.23 72.92
Pathology 29.84 40.73 52.33 71.39 73.92 72.75
Δ (%) −0.95% −0.45% −28.95% −0.08% −1.75% −0.23%

Under our setting, there are two findings:

  • Removing one modality does not consistently improve the others. Although the remaining modalities receive more samples, all their average changes stay within ±0.45%. This suggests that the modalities do not compete for model capacity in this setting.
  • Removing a modality mainly hurts that modality. Without pathology data, pathology accuracy drops by 28.95%, while PSNR and Dice drop by only 0.95% and 1.75%. This suggests that basic image structure transfers across modalities, but modality-specific semantics still require direct exposure to that modality.

We hypothesize that, in MERA's training, diverse modalities provide a wider range of visual patterns and expert signals. This broadens the learned semantic space and regularizes training; adding more samples from fewer modalities does not replace that coverage. Within these two tests, multimodal training preserves each modality without harming the others.


Q2. (Discussion on MedVTok adaptation) Given an unseen modality, how can we adapt/finetune a trained MedVTok model to this new modality, and does the finetuned MedVTok model perform better than other generalist tokenizer baselines finetuned in the same way?

Thanks for raising this valuable direction.

Before discussing how we would adapt the foundation model, we first established how well MedVTok's frozen representation naturally transfers to a genuinely unseen modality.

We evaluate the frozen tokenizers on PBC, a hematology microscopy dataset whose data and modality are both absent from MedVTok pretraining. This complements the PBC t-SNE visualization included in our appendix (Fig. 11). We apply both k-NN classification and a linear classifier adaptation on frozen representations, two common ways of adapting a pretrained tokenizer to downstream tasks.

Models k-NN Acc. Downstream linear Acc.
MedVAE 40.47 ± 0.15 79.47 ± 1.35
PUMIT 36.98 ± 0.55 83.25 ± 0.84
MedITok 90.73 ± 0.62 94.62 ± 0.76
AToken 92.00 ± 2.07 92.84 ± 0.87
MedVTok 94.78 ± 1.81 96.84 ± 0.59

MedVTok outperforms all generalist baselines under both protocols, indicating that its unified representation generalizes well to unseen modalities.

Apart from the above two protocols, there are other approaches for active adaptation of the foundation tokenizer; The amount of adaptation can follow the available data: a lightweight adapter module and low-rank adapters for a small dataset, or lower-learning-rate full-model continual pretraining for a large corpus. We leave these in our future exploration.

Reviewer qrJP · CommentOpenReview ↗

Thank you very much for your response. My score remains positive.

Authors · CommentOpenReview ↗

Thank you for your encouraging response! We appreciate your insightful comments on the medical multimodal learning, and are grateful for the time and effort throughout the review process, as well as your continued support of our work.

Reviewer yovpOpenReview ↗
Rating
4/6
Confidence
5/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
use_inspired
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This work addresses the central challenge of building a reusable medical visual tokenizer that can encode heterogeneous 2D images and 3D volumes into a unified token space for downstream multimodal medical AI. The proposed MedVTok combines autoencoding reconstruction, slice differential regularization for volumetric continuity, and multi-expert representation alignment using frozen medical encoders. The model is trained at large scale on 28M 2D images and 70K 3D volumes, and evaluated on reconstruction, classification, retrieval, segmentation, synthesis, VQA, and report generation benchmarks. The claims of the paper are ambitious: MedVTok is positioned as a general-purpose tokenizer unifying medical image dimension, modality, and task usage.

Strengths and weaknesses

Strengths 1.A unified visual token interface for medical multimodal modeling is a timely and relevant problem. The paper clearly identifies two desirable properties: structural fidelity across 2D/3D inputs and semantic alignment across medical imaging modalities. This framing is useful for future generalist medical AI systems. 2.The training corpus is substantial, with 28,769,502 2D images and 70,144 3D volumes across 9 imaging modalities. The evaluation spans multiple task families, including reconstruction, classification, retrieval, segmentation, synthesis, VQA, and report generation. 3.The architecture supports mixed-resolution and mixed-dimensional patchification, block-diagonal attention masking to prevent cross-sample leakage, and 3D coordinate-based positional encoding. The appendix gives useful implementation details, including encoder/decoder sizes, patch sizes, latent dimensionality, and expert encoders used for alignment.

Major Weaknesses 1.The methodological novelty is limited. The core recipe is largely a combination of existing ideas: autoencoding-based visual tokenization, semantic alignment to pretrained encoders, multi-teacher distillation, and 2D/3D patchification. MedITok already frames medical tokenization as the joint preservation of low-level structure and high-level clinical semantics, and reports large-scale training on over 30M medical images and 2M image-caption pairs [1]. AToken [2] already proposes a unified visual tokenizer for images, videos, and 3D assets using a shared latent space and rotary positional encoding. Therefore, the paper’s main conceptual contribution appears closer to an engineering extension of existing tokenizer paradigms to a larger medical 2D/3D corpus than a fundamentally new tokenizer methodology. The paper should more explicitly distinguish MedVTok from recent unified tokenizers and compact visual tokenization methods. In particular, related work on compact mask or visual token interfaces for MLLMs is under-discussed. SAMTok [3], for example, converts arbitrary region masks into two special tokens and enables MLLMs to learn pixel-wise capabilities through next-token prediction and reinforcement learning. HiMTok[4] similarly represents segmentation masks with up to 32 hierarchical tokens and aligns segmentation with the LLM next-token-prediction paradigm. Although these works are not identical in task setting, they are highly relevant to the broader claim that dense medical visual evidence can be compressed into a reusable token interface. 2.MERA is better described as modality-routed multi-teacher distillation rather than a clearly novel multi-expert integration mechanism. MERA aligns MedVTok representations with features from multiple frozen expert encoders using a shared-space contrastive loss and an expert-space cosine loss. This design is plausible, but it is not clear that it learns genuinely complementary cross-expert knowledge. Since each sample appears to be routed to its corresponding modality expert, the method does not demonstrate non-trivial fusion of multiple experts on the same input. The “expert-space complementary alignment” may simply train a modality-specific projector to reconstruct each expert’s feature space. 3.The experimental gains are confounded by data scale, initialization, teacher supervision, and compute. The proposed model is trained on a very large dataset and uses multiple strong expert encoders. The baselines, however, do not appear to be retrained under the same data scale, compute budget, initialization, and expert supervision. The current experiments do not adequately isolate these factors. This is a serious issue because the paper’s main claim is methodological, not merely that a larger model trained on more data performs better. The paper should include controlled comparisons where MedVTok and key baselines are trained on the same subset, with matched token budget, comparable parameter count, and comparable training recipe. At minimum, the authors should report MedVTok trained under the MedITok-scale setup, and/or retrain MedITok/AToken-style baselines on the same medical corpus.

4.VQA and report generation results do not purely evaluate tokenizer quality. For VQA, the frozen tokenizer is plugged into LLaVA-Med, but the connector and LLM are trained. The appendix further states that the setup uses Mistral-7B-Instruct, connector training, LoRA fine-tuning, and Qwen3-235B-A22B as LLM-as-judge. For report generation, the tokenizer is integrated into a LaMed-style framework with Llama-3.1-8B-Instruct and LoRA. These experiments are useful downstream demonstrations, but they introduce substantial confounding from the connector, LLM backbone, fine-tuning data, LoRA setting, decoding strategy, and judge model. The paper should include additional controls such as connector-only training, frozen-LLM evaluation, multiple LLM backbones, exact-match metrics for closed-form VQA, and judge sensitivity analysis.

5.The proposed loss of SliDR should be positioned as depth-direction reconstruction-gradient regularization rather than anatomical coherence modeling. Please compare against standard gradient, TV, and Laplacian regularizers. Also evaluate whether SliDR hurts small lesions or thin anatomical structures due to over-smoothing.

Reference [1] Ma, C., Ji, Y., Ye, J., Li, Z., Wang, C., Ning, J., ... & Shan, H. (2025). MedITok: A Unified Tokenizer for Medical Image Synthesis and Interpretation. arXiv preprint arXiv:2505.19225. [2] Lu, J., Song, L., Xu, M., Ahn, B., Wang, Y., Chen, C., ... & Yang, Y. (2026). Atoken: A unified tokenizer for vision. In Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition (pp. 28701-28711). [3] Zhou, Y., Zhang, T., Gong, D., Wu, Y., Tian, Y., Wang, H., ... & Li, X. (2026). Samtok: Representing any mask with two words. In Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition (pp. 37852-37863). [4] Wang, T., Cheng, C., Wang, L., Chen, S., & Zhao, W. (2025). Himtok: Learning hierarchical mask tokens for image segmentation with large multimodal model. In Proceedings of the IEEE/CVF International Conference on Computer Vision (pp. 23267-23278).

The work is relevant and technically competent, but the contribution is incremental relative to recent unified visual tokenizer and compact visual-token interface literature. The proposed components are reasonable but not sufficiently novel or deeply validated. Stronger controlled baselines, direct 3D downstream experiments, and more rigorous analysis of SliDR/MERA are needed before I would support acceptance.

Questions

Given that training requires 16 NVIDIA H200 GPUs with a peak memory usage of 132.54 GB per device, can the authors further discuss the scalability of the proposed method and clarify whether smaller model variants can preserve the claimed benefits?

Since confidence intervals are reported for VQA and report generation but not for many core reconstruction, classification, retrieval, and segmentation results, could the authors provide more complete uncertainty reporting to better support the empirical claims?

Limitations

Please see the weaknesses.

Final justification

The rebuttal improves my assessment of the submission. The matched-data comparison, connector-only VQA results and direct 3D segmentation experiments address most of my concerns regarding data-scale confounding and downstream volumetric validation. I also appreciate the clarification that MERA is intended as modality-routed representation alignment rather than same-input multi-expert fusion.

I retain reservations regarding methodological novelty. The overall framework combines established ideas in unified tokenization, multi-teacher semantic alignment, and depth-wise reconstruction regularization. SliDR appears useful but provides relatively modest improvements over the direct-gradient baseline, while MERA is closer to multi-expert distillation than a fundamentally new fusion mechanism. Thus, I view the contribution primarily as a strong large-scale medical tokenizer system rather than a major methodological advance.

Nevertheless, given the substantial scale of the work, broad evaluation and the authors’ comprehensive and experimentally grounded rebuttal, I am now marginally in favor of acceptance.

Formatting concerns

NA

3 comments
Authors · RebuttalOpenReview ↗
Rebuttal

Thank you for your detailed assessment and constructive feedback. Below, we address your concerns point-by-point.


W1. (Contribution relative to related works) The methodological novelty is limited... The paper should more explicitly distinguish MedVTok from recent unified tokenizers and compact visual tokenization methods...

MedVTok addresses a distinct problem: building a unified visual token interface for heterogeneous medical images that preserves both modality-specific clinical semantics and native 2D/3D spatial structures.

This requires two capabilities not addressed by previous works:

  1. a unified tokenizer supporting both 2D and 3D data with explicit preservation of through-plane anatomical continuity;
  2. a multimodal semantic space that captures shared clinical concepts while retaining modality-specific knowledge.

Specifically:

  • MedITok: limited to 2D and focuses on balancing reconstruction fidelity and semantic alignment.
  • AToken: targets general-domain images, videos, and renderings, but does not address heterogeneous medical imaging modalities and their modality-specific semantics.
  • SAMTok/HiMTok tokenize segmentation masks (instead of raw images/volumes) into tokens for enabling pixel-level grounding in MLLMs. They share the broader vision of reusable visual token interfaces but targeting fundamentally different problems.

MedVTok differs by introducing:

  • SliDR, which explicitly preserves through-plane anatomical continuity beyond pixel/voxel reconstruction.
  • MERA, which learns shared multimodal semantics while preserving modality-specific knowledge from multiple medical experts.

Detailed discussion of these related works will be included in the revision.


W2. (About MERA) ... it is not clear that it learns genuinely complementary cross-expert knowledge... the method does not demonstrate non-trivial fusion of multiple experts on the same input ...

Thanks for the insightful comment. We clarify that MERA is not designed to fuse multiple experts for the same input. Instead, its goal is to learn a unified token space that preserves both:

  1. shared clinical semantics across modalities;
  2. modality-specific semantic characteristics captured by different experts.

Each sample is routed to its corresponding modality expert. The complementary alignment does not combine multi-expert outputs. Rather, it prevents the modality-specific information from being lost when heterogeneous expert representations are projected into a single shared space. The shared-space loss encourages common semantic organization, while the expert-space loss preserves modality-specific knowledge that may be discarded during projection.

Our ablations (Fig. 5) support this:

  1. Replacing a single expert with multi-experts (E2→E3) improves downstream performance, showing that multi-experts provide complementary semantic coverage.
  2. Adding expert-space loss (E3→E4) provides additional gains, showing the benefit of preserving modality-specific semantics.

We will revise the manuscript to clarify that “complementary knowledge” refers to complementary modality-specific semantics retained in the unified token space, rather than per-sample expert fusion.


W3. (About confounding factors) The experimental gains are confounded by data scale, initialization, teacher supervision, and compute...

We clarify that Fig. 5 provides controlled ablations: E1–E5 use identical data, initialization, architecture, optimization, and compute budget to isolate the effect of alignment strategies.

Furthermore, we conducted a matched comparison by retraining MedVTok, AToken, and MedITok using MedITok’s 2M image-text paired dataset under identical settings. Note that AToken and MedITok exploit text supervision, whereas MedVTok uses only images.

The results show that, MedVTok remains superior under this matched regime despite not using image-text supervision.

Model Recon. PSNR Cls. Acc. Seg. Dice
AToken 39.35 63.65 69.57
MedITok 36.83 66.59 67.01
MedVTok 39.71 71.70 73.21

W4. (About VQA and report-generation setup) VQA and report generation results ... introduce substantial confounding ...

We agree these tasks involve multiple components, but we respectfully clarify that all external factors are strictly fixed across tokenizers within each task:

  • VQA: identical LLaVA-Med architecture, connector, LLM, LoRA settings, data, decoding, and judge. Common for 2D VQA task [1,2].
  • Report Generation: identical LaMed configurations, which is designed for 3D data [3,4].

These experiments evaluate how well different tokenizers provide transferable visual representations under the same downstream pipeline.

1. Connector-only Training

Per your request, we froze the LLM and trained only the connector:

Models Connector only (%) Connector + LLM LoRA (%)
PUMIT 23.05±0.44 41.94±0.33
MedVAE 17.88±0.48 39.93±0.41
MedITok 24.76±0.39 45.39±0.28
MedVTok 29.86±0.36 46.48±0.22

While freezing the LLM drops performance globally, MedVTok remains the best, showing that the advantage originates from visual representation quality rather than LLM adaptation.

2. LLM Judge Robustness

We also explored substituting the Qwen3-235B judge with GPT-5. GPT-5 yields stricter scores but the tokenizer rankings remain unchanged:

Models Qwen3-235B judge (%) GPT-5 judge (%)
PUMIT 41.94±0.33 41.83±0.33
MedVAE 39.93±0.41 39.58±0.42
MedITok 45.39±0.28 44.82±0.26
MedVTok 46.48±0.22 46.02±0.24

[1] LLaVA-Med: Training a Large Language-and-Vision Assistant for Biomedicine in One Day (NeurIPS'24)

[2] Unified Medical Image Tokenizer for Autoregressive Synthesis and Understanding (arxiv'25)

[3] M3D: Advancing 3D Medical Image Analysis with Multi-Modal Large Language Models (arxiv'24)

[4] Exploring the Design Space of 3D MLLMs for CT Report Generation (MICCAI'25)


W5. (About SliDR variants)... Please compare against standard gradient, TV, and Laplacian regularizers. Also evaluate whether SliDR hurts small lesions or thin anatomical structures due to over-smoothing.

This is an excellent point. We trained different depth-objective variants from the same 2D-trained MedVTok checkpoint on a controlled 10K-volume subset and evaluated their reconstruction on AMOS-MM CT and MRISegmenter MRI:

Objective CT PSNR CT SSIM MR PSNR MR SSIM
Direct gradient 33.24±0.22 93.01±0.25 26.11±0.14 78.62±0.44
TV 33.05±0.21 93.08±0.24 26.04±0.14 78.00±0.45
Laplacian 32.99±0.21 93.08±0.24 26.20±0.15 77.86±0.45
SliDR 33.46±0.22 93.21±0.25 26.23±0.15 78.70±0.44

TV and Laplacian penalize differences without reference to the ground truth (GT), which suppresses real discontinuities. In contrast, SliDR matches both derivatives directly to the GT volume. Together with the reconstruction loss, small anatomical structures contribute to the GT derivatives rather than being driven to zero. SliDR achieves the best performance on both datasets.


W6. (About direct 3D downstream experiments)

Per your suggestion, we evaluated direct 3D segmentation transfer on AMOS-MM CT and MRISegmenter MRI. Tokenizers were frozen and only a lightweight 3D segmentation head was trained.

AMOS-MM CT Dice.

Model Overall Spleen Kidney Liver Pancreas Adrenal Gallbl. Esoph. Stomach Duod. Major vessels
PUMIT 28.67 63.68±1.58 48.94±1.96 76.63±2.68 13.42±1.99 16.50±1.30 18.78±2.21 16.29±1.02 4.96±0.76 3.37±1.73 24.14±1.82
MedVAE-3D 29.71 42.94±2.64 45.95±2.36 73.73±2.23 23.51±2.60 12.74±1.10 16.33±2.99 18.59±2.98 3.71±0.76 10.44±2.00 49.19±2.05
AToken 36.89 55.76±2.46 59.56±2.44 80.50±1.72 31.64±2.72 20.44±1.47 14.93±1.82 15.14±1.80 34.63±3.53 15.04±1.46 41.22±1.65
MedVTok 50.13 70.61±2.30 74.93±1.74 86.31±1.00 41.90±2.36 23.64±1.76 39.69±4.57 19.04±2.68 62.15±3.87 30.48±2.71 52.53±1.37

MRISegmenter MRI Dice.

Model Overall Spleen Kidney Liver Pancreas Adrenal Gallbl. Esoph. Stomach Duod. Major vessels
PUMIT 44.57±0.76 40.83±2.12 81.60±1.29 58.11±1.32 49.43±2.22 24.00±1.43 24.20±3.46 48.05±1.82 40.66±2.03 14.82±1.64 64.00±1.28
MedVAE-3D 43.70±0.80 40.68±2.14 77.46±1.77 59.11±1.23 43.98±2.08 21.69±1.87 23.31±3.27 39.28±2.26 46.67±2.05 16.41±1.62 68.46±1.18
AToken 54.63±0.68 63.28±2.71 83.96±0.67 85.71±0.94 49.23±1.92 25.63±1.49 32.85±3.68 44.92±1.79 52.08±1.30 40.11±1.75 68.52±0.91
MedVTok 57.20±0.76 70.60±2.85 86.48±0.95 85.83±0.70 49.49±2.71 23.16±1.64 34.94±3.76 52.78±1.61 59.89±2.30 39.23±1.80 69.56±0.93

MedVTok achieves the best performance on both datasets, demonstrating that the learned 3D tokens effectively preserve volumetric anatomical information.


Q1. (About computational cost and scalability of the method)

Thanks for raising this practical question.

1. Regarding computational cost: We clarify that the 132.54 GB footprint is a one-time pretraining requirement (large batch sizes, optimizer states). For downstream usage, MedVTok runs easily on a single RTX 4090, matching existing methods in efficiency:

Models Params. (M) 512² GFLOPs Peak mem. (GiB)
MedITok 696.65 3072.22 4.318
AToken 845.74 1965.42 4.837
MedVTok 831.83 1959.50 4.772

2. Regarding scalability: Our core designs (SliDR and MERA) are independent of model size. Also, MedVTok enjoys the scalability of Transfromer backbones. Therefore, its scaled-down version would preserve structural/semantic benefits of unified token space (with reduced capacity), representing a promising direction for future work. Fig. 5 further demonstrates data scalability, with consistent improvements from 3M to 28M images.

Q2. (About the uncertainty reporting).

Thanks for the suggestion. We will include 95% confidence intervals for the core experiments in the revised manuscript.

Reviewer yovp · CommentOpenReview ↗

Official Comment

Thank you for the rebuttal. The rebuttal improves my assessment of the submission. The matched-data comparison, connector-only VQA results and direct 3D segmentation experiments address most of my concerns regarding data-scale confounding and downstream volumetric validation. I also appreciate the clarification that MERA is intended as modality-routed representation alignment rather than same-input multi-expert fusion.

I retain reservations regarding methodological novelty. The overall framework combines established ideas in unified tokenization, multi-teacher semantic alignment, and depth-wise reconstruction regularization. SliDR appears useful but provides relatively modest improvements over the direct-gradient baseline, while MERA is closer to multi-expert distillation than a fundamentally new fusion mechanism. Thus, I view the contribution primarily as a strong large-scale medical tokenizer system rather than a major methodological advance.

Nevertheless, given the substantial scale of the work, broad evaluation and the authors’ comprehensive and experimentally grounded rebuttal, I raised the score.

Authors · CommentOpenReview ↗

Thank you very much for your reconsideration and your decision to raise the score! We appreciate your recognition of the additional experiments and clarifications, and will sharpen the framing and positioning of our contributions in the revised manuscript. Thank you again for your thorough and thoughtful assessment.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.