Abstract. Whole-slide images (WSIs) are gigapixel-scale digital scans of histopathology tissue and serve as the primary basis for cancer diagnosis. Existing histopathology generative models operate at the patch scale, producing fixed-size tiles of at most 1024$\times$1024 pixels which encompass only a small fraction of the WSI. In contrast, text reports for clinical diagnoses and slide-level diagnostic labels -- the supervision that exists at scale -- operate at the whole-slide level. We present BigCell, the first approach to generate coherent whole-slide histopathology images at native gigapixel resolution. BigCell trains a flow-matching transformer at 2048$\times$2048 pixels on over 120,000 publicly available WSIs spanning multiple organ types. Conditioning on embeddings from pathology foundation models and using an inference-time sliding-window pipeline, BigCell generates coherent images of up to 32,768$\times$32,768 pixels, outperforming prior tile generators on both tile-level and slide-level fidelity metrics. To make gigapixel synthesis practical, we introduce an adaptive scheduling strategy that prioritizes important slide regions, speeding up image generation by over 3$\times$ with minimal quality degradation. Furthermore, we propose the first text-to-image synthesis at 8k resolution by training a separate model that produces dense conditioning grids directly from pathology text reports. We demonstrate that augmenting with synthetic samples improves slide-level few-shot classification performance by up to 18%18 \% over baselines trained on real data.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
16 Apr 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:45 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

In this manuscript, the authors address the challenge of generating coherent histopathology images at whole-slide scale through a flow-matching tile generator. Overall, the reviewers appreciated the strengths of the manuscript including the ambitious scale of the system, its practical scheduling strategy, broad evaluation, high-resolution text-conditioned generation, and evidence that synthetic samples can improve few-shot classification. The claims of the manuscript, however, require more careful qualification because the asserted first-of-its-kind novelty is disputed, comparisons with highly relevant large-scale generation methods are missing, and the current baseline evaluation conflates model design with native training resolution. In addition, the reliance on related foundation-model spaces for both conditioning and evaluation raises concerns about metric circularity, while the small 8K human study does not fully validate biological realism or coherence at 32K. Overall, I find this submission significant and technically ambitious, but currently borderline due to insufficiently established novelty, incomplete comparisons, and limitations in the independent validation of gigapixel-scale realism.

Final justification

The rebuttal and discussion materially improve the case for this submission, and all three reviewers now assign a borderline-accept rating (4/4/4). The authors narrowed the novelty claim to whole-slide generation at native 20x resolution, added resolution-matched comparisons including LRDM and ZoomLDM, clarified distinctions from prior coarse-to-fine and mask-conditioned approaches, and provided an additional slide-level evaluation using MedGemma rather than a pathology foundation model. These additions reduce the earlier baseline-resolution and metric-circularity concerns and strengthen the empirical validation at large scale. The reviewers nevertheless agree that the broad "first gigapixel WSI generation" claim was overstated, and the revised claim makes the contribution primarily a strong system-level scaling and integration advance rather than an entirely new generative paradigm. Direct comparison with some closely related methods remains unavailable, the human study is limited, and the biological realism and coherence of 32K outputs are not exhaustively validated. On balance, however, the rebuttal demonstrates meaningful progress on an important and underexplored problem, and the unanimous final reviewer stance is positive. I therefore recommend acceptance. The final paper should precisely scope the novelty claim, clearly describe the architecture and scheduling pipeline, and prominently discuss validation and misuse limitations for synthetic medical images.

Area Chair MZ5U · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

In this manuscript, the authors address the challenge of generating coherent histopathology images at whole-slide scale through a flow-matching tile generator. Overall, the reviewers appreciated the strengths of the manuscript including the ambitious scale of the system, its practical scheduling strategy, broad evaluation, high-resolution text-conditioned generation, and evidence that synthetic samples can improve few-shot classification. The claims of the manuscript, however, require more careful qualification because the asserted first-of-its-kind novelty is disputed, comparisons with highly relevant large-scale generation methods are missing, and the current baseline evaluation conflates model design with native training resolution. In addition, the reliance on related foundation-model spaces for both conditioning and evaluation raises concerns about metric circularity, while the small 8K human study does not fully validate biological realism or coherence at 32K. Overall, I find this submission significant and technically ambitious, but currently borderline due to insufficiently established novelty, incomplete comparisons, and limitations in the independent validation of gigapixel-scale realism.

Final justification

The rebuttal and discussion materially improve the case for this submission, and all three reviewers now assign a borderline-accept rating (4/4/4). The authors narrowed the novelty claim to whole-slide generation at native 20x resolution, added resolution-matched comparisons including LRDM and ZoomLDM, clarified distinctions from prior coarse-to-fine and mask-conditioned approaches, and provided an additional slide-level evaluation using MedGemma rather than a pathology foundation model. These additions reduce the earlier baseline-resolution and metric-circularity concerns and strengthen the empirical validation at large scale. The reviewers nevertheless agree that the broad "first gigapixel WSI generation" claim was overstated, and the revised claim makes the contribution primarily a strong system-level scaling and integration advance rather than an entirely new generative paradigm. Direct comparison with some closely related methods remains unavailable, the human study is limited, and the biological realism and coherence of 32K outputs are not exhaustively validated. On balance, however, the rebuttal demonstrates meaningful progress on an important and underexplored problem, and the unanimous final reviewer stance is positive. I therefore recommend acceptance. The final paper should precisely scope the novelty claim, clearly describe the architecture and scheduling pipeline, and prominently discuss validation and misuse limitations for synthetic medical images.

Reviewer d5h8OpenReview ↗
Rating
4/6
Confidence
3/5
Quality
2/4
Clarity
2/4
Significance
3/4
Originality
2/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper proposes "BigCell," a novel flow-matching-based generative model designed to synthesize gigapixel-scale Whole Slide Images (WSIs). The model is trained on a massive dataset comprising 120,000 publicly available pathology slides, enabling it to generate high-fidelity images at a 2048×20482048 \times 2048 resolution. Furthermore, the proposed method successfully achieves text-to-image synthesis at an 8K resolution, demonstrating significant scalability and potential for digital pathology applications.

Strengths and weaknesses

Strengths:

  • High-Resolution Generation: The paper demonstrates successful text-to-image generation at an impressive resolution of 8192, pushing the boundaries in this context.
  • Efficiency Improvements: By incorporating classifier-free guidance and a sliding window approach, the proposed method achieves a notable 3x speedup in generation time.

Weaknesses:

  • Unclear Technical Contribution and Lack of Comparison: The technical distinctiveness of the proposed method remains ambiguous. While the authors argue that their approach differs from Herb et al. [19] by avoiding a coarse-to-fine super-resolution pipeline, generating the entire image at once could inherently pose a higher risk of hallucination. Without a direct empirical comparison, it is difficult to validate the justification or superiority of this design choice.
  • Overstatement of Originality: In the contributions section, the authors claim that BigCell is the first method for gigapixel whole-slide image (WSI) generation. However, existing literature such as [17, 48, 19] appears to have already addressed this task. The current description lacks precision, and it is unclear what specific aspect makes this work the "first."
  • Incremental Novelty over Prior Work: Beyond adapting LRDM [16] to the digital pathology domain, the core technical novelty is difficult to discern from the current manuscript.
  • Lack of Clarity in the Architectural Pipeline: The exact flow of image dimensions and latent vectors is confusing. For instance, while an 8×88 \times 8 latent condition is used for conditioning z∈R256×256×32z \in \mathbb{R}^{256 \times 256 \times 32}, the specific mechanism for decoding or restoring this to the final 2048×20482048 \times 2048 resolution is not adequately explained.
Questions
  • Risk of Hallucination vs. Super-Resolution: You argue that your method is superior to Herb et al. [19] because it avoids a coarse-to-fine super-resolution pipeline. However, generating an entire WSI at once could arguably increase the risk of artifact or hallucination generation. Could you provide quantitative or qualitative evidence to support your choice? A direct comparison with [19] would greatly strengthen the paper.
  • Clarification on the "First" Claim: In your contributions, you state that BigCell is the first method for gigapixel WSI generation. Could you clarify the exact distinction between your work and existing methods like [17, 48, 19] that seem to target the same problem? What specific technical or task-level element justifies the "first" designation?
  • Core Technical Novelty: Apart from adapting LRDM [16] to the digital pathology domain with a larger dataset, what are the key methodological innovations introduced in this work?
  • Detailed Architecture Pipeline: Could you clarify the exact transformation and flow of image dimensions and latent vectors? Specifically, how is the 8×88 \times 8 latent condition utilized in the context of z∈R256×256×32z \in \mathbb{R}^{256 \times 256 \times 32}, and what is the exact mechanism for decoding or restoring this representation to the final 2048×20482048 \times 2048 resolution?
Limitations

yes

Final justification

As indicated in my comments, I lean toward a positive evaluation since the method offers a new direction in this field, though its actual description needs refinement.

Formatting concerns

No

5 comments
Authors · RebuttalOpenReview ↗
Rebuttal

W1: Unclear Technical Contribution and Lack of Comparison: The technical distinctiveness of the proposed method remains ambiguous. While the authors argue that their approach differs from Herb et al. [19] by avoiding a coarse-to-fine super-resolution pipeline, generating the entire image at once could inherently pose a higher risk of hallucination. Without a direct empirical comparison, it is difficult to validate the justification or superiority of this design choice. W2: Overstatement of Originality: In the contributions section, the authors claim that BigCell is the first method for gigapixel whole-slide image (WSI) generation. However, existing literature such as [17, 48, 19] appears to have already addressed this task. The current description lacks precision, and it is unclear what specific aspect makes this work the "first."

Response: We address them together

On the "first" claim. We claim BigCell is the first method to generate gigapixel whole-slide images at native resolution. Harb et al [19] samples a 512×512512 \times 512 image and upscales it to 65536×6553665536 \times 65536 through a cascade, so cellular morphology is produced by the refinement stages. Moreover, their method is unconditional throughout - there is no mechanism to specify what tissue appears where. BigCell denoises every region at 20×20 \times conditioned by dense UNI-2 embedding grids.

Hallucination risk. The reviewer raises a fair concern. We believe full-resolution generation reduces this risk rather than increasing it. In the coarse-to-fine cascade of Harb et al, detail at 20×20 \times can not be specified by the initial 512×512512 \times 512 guide, so the later refinement stages must invent it independently from each other. A tissue region that is on one side of the slide is generated conditioned only on the local blurry pixels of the previous stage and is never informed of what will be generated on the other side.

In BigCell, every 2048×20482048 \times 2048 window is denoised under dense conditioning that specifies fine-grained morphology, so structure is determined by the conditioning blueprint. Global coherence is ensured by either using a reference slide or the CGM which generates the conditions jointly, having a "full picture" of the slide to be synthesized. Our tail metrics show this: V25thV2_{5th}, the bottom-5th-percentile patch similarity, is the statistic that shows locally implausible regions, and BigCell reaches 0.737 against 0.632 for the strongest prior generator (Table 1).

Direct comparison. We agree that it would strengthen the paper. Unfortunately, Harb et al. [19] releases neither code nor trained weights, so it can not be run on our data. We have instead added comparisons with LRDM [16] and ZoomLDM [49], both publicly available, at 8192×81928192 \times 8192 resolution (see our response to Reviewer MKSc Q2).

W3: Incremental Novelty over Prior Work: Beyond adapting LRDM [16] to the digital pathology domain, the core technical novelty is difficult to discern from the current manuscript.

The contribution of BigCell is gigapixel generation at native resolution. Two components make this possible:

Efficiency. Sliding-window generation at 32k resolution requires hundreds of forward passes at every denoising step. Our adaptive scheduling strategy reduces this by a factor of 3.1×3.1 \times with negligible quality degradation, is training-free, and requires a single interpretable hyperparameter (Section 3.3).

Controllability. The CGM samples a dense conditioning grid jointly from a pathology report, capturing the long-range dependencies present at this scale (Section 3.4). It enables the first text-conditioned histopathology generation at 8192×81928192\times8192, as well as the augmentation procedure of Section 3.5.

On LRDM [16], we note that it is a histopathology method and that its sliding-window formulation originates in MultiDiffusion [4]; we extend that formulation to flow matching in Appendix A. The difference is best seen empirically: under an identical protocol on identical data at 8192×8192, LRDM achieves a TITAN similarity of 0.531, compared to 0.956 for BigCell (See our response to Reviewer MKSc Q2).

W4: Lack of Clarity in the Architectural Pipeline

Response: We thank the reviewer, and will add an explicit specification of the dimension flow to the appendix.

For a single 2048×2048 tile:

Step Tensor Shape
Input tile image 2048 × 2048 × 3
VAE encode latent z 256 × 256 × 32
Conditioning: 64 non-overlapping 256×256 patches → UNI-2 grid y 8 × 8 × 1536
Denoising v_θ(z_t, t, y), with y entering via cross-attention 256 × 256 × 32
VAE decode image 2048 × 2048 × 3

The generated object is the 256×256×32 latent, and the final resolution is restored by a single decode through the Flux-2 VAE [24], at a fixed 8×8 \times spatial factor. The 8×8×1536 grid conditions this process through cross-attention and is not part of the decode path.

With larger canvases the same relationship holds by scaling both tensors: for a 32,768×32,768 image the conditioning grid is 128×128×1536 and the latent canvas is 4096×4096×32. Each sliding window denoises a 256×256×32 latent region conditioned on the corresponding 8×8×1536 slice of the global grid; per-window velocities are aggregated into a global velocity field (Section 3.2, Appendix A), and the canvas is decoded once after the final denoising step.

Reviewer d5h8 · CommentOpenReview ↗

Thank you for the rebuttal. Most of my concerns have been addressed. In the main text, however, I believe the phrasing "the first method to generate gigapixel whole-slide images" needs to be reconsidered.

In addition, the key concepts of "Efficiency" and "Controllability" in this paper are described quite abstractly, and the figures lack a clear conceptual explanation of them. Looking at Figure 2 alone, it simply appears to perform latent generation, making the essence of the proposed method unclear and hard for many readers to follow. If possible, it would be beneficial to illustrate these two key concepts directly in the figure.

I also understand the difficulty of making direct comparisons. If the source code for this paper is released, I believe this work could serve as an approach that advances the field beyond conventional generation methods.

At this point, I am leaning toward a positive view regarding the novelty and methodology, but remain somewhat negative concerning the quality of the manuscript.

Authors · CommentOpenReview ↗

We thank the reviewer for the updated assessment.

Precision of the "first" claim. We agree with the reviewer that phrasing should be sharper, and we will state the claim as "BigCell is the first method to generate gigapixel whole-slide images at native resolution." This is also precisely the distinction from prior gigapixel work: Harb et al. [19] reach gigapixel outputs by progressively super-resolving a 512x512 thumbnail. We will use the revised phrasing consistently in the abstract, introduction, and contributions list.

Figure 2 - making controllability and efficiency explicit. We agree that the current figure emphasizes the mechanics of latent generation. We will annotate it in the following way:

  • Controllability will be labeled over panel (a), the construction of the dense conditioning grid. We will add a short caption cue that the grid acts as the global blueprint needed to control slide content.
  • Efficiency will be labeled over panels (b) - (c), where the tile generator decodes the conditioning grid into pixels. We will also overlay the CFG-magnitude importance map on the sliding window schematic.

Code release. As stated in the paper, we will release the full pipeline: training and inference code, BigCell tile generator and CGM weights, and synthetic WSIs generated with our method, upon acceptance.

Reviewer MKScOpenReview ↗
Rating
4/6
Confidence
4/5
Quality
3/4
Clarity
2/4
Significance
3/4
Originality
2/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper introduces BigCell, a flow-matching transformer framework for large-scale histopathology whole-slide image generation. The method trains a 2048×2048 tile generator conditioned on dense pathology foundation-model embeddings, and extends it to slide-level synthesis through sliding-window inference, reaching resolutions up to 32768×32768. To improve efficiency, the authors propose an adaptive window scheduling strategy based on the gap between conditional and unconditional predictions. They also develop a report-to-embedding-grid model for 8192×8192 text-conditioned synthesis. Experiments against existing tile-level pathology generators show improved tile- and slide-level fidelity, and the synthetic data is further shown to benefit few-shot slide-level classification.

Strengths and weaknesses

Strengths: The paper addresses an important and timely problem: whole-slide-scale generative modeling in computational pathology. The system is ambitious, and the engineering effort is clearly substantial. Using pathology foundation-model embeddings as dense conditioning grids is a reasonable design choice, since it provides a slide-level blueprint without requiring expensive pixel-level annotations. The adaptive scheduling strategy is also practical. Using the strength of conditional guidance as a proxy for window importance is simple, and it gives a useful speedup without the need for retraining. The few-shot augmentation results and the pathologist evaluation further make the empirical case stronger.

Weaknesses: My main concern is that the paper overstates its novelty. The claim of being the first gigapixel WSI generation method needs to be more carefully qualified. Prior work, such as Harb et al. 2024, has already studied diffusion-based histopathology WSI generation at gigapixel scale, and DiffInfinite also targets arbitrarily large histopathology image synthesis with long-range structure. In my view, the novelty of BigCell is more specific: WSI-scale generation conditioned on foundation-model embeddings, a higher native-resolution tile generator, report-to-conditioning-grid synthesis, and CFG-magnitude-based adaptive scheduling. These are meaningful system-level contributions, but they are not as fundamental as the current framing suggests.

The comparison set is also not complete enough. The paper compares with PixCell, CytoSyn, and MuPaD, which is useful for evaluating the tile generator. However, it does not include direct quantitative comparisons with several highly relevant large-image or WSI-scale methods, especially Harb et al., DiffInfinite, LRDM, and ZoomLDM. Since the main claim is about gigapixel whole-slide synthesis, the lack of comparison with these methods weakens the evidence behind both the novelty claim and the performance claim.

The evaluation is fairly broad, but some of the metrics rely heavily on foundation-model similarity. These metrics are useful, but they may also favor methods that use related foundation-model embeddings as conditioning. The paper should discuss more clearly whether the evaluation is sufficiently independent from the conditioning representation. The pathologist study is helpful, but it is still small, and by itself it is not enough to establish clinical realism or diagnostic reliability.

Finally, the computational cost remains high. Even with adaptive scheduling, generating a 32k image still takes several hours on a single GPU. This does not negate the contribution, but it does limit the practical value of the method and should be reflected in a more measured framing.

Questions
  1. Please clarify the “first” claim. In particular, how is BigCell different from Harb et al. 2024, which also studies gigapixel histopathology WSI generation? I would be more positive about the originality if the paper narrowed this claim and clearly explained the specific novelty of BigCell relative to prior gigapixel WSI generation methods.

  2. Can the authors provide more direct comparisons with Harb et al., DiffInfinite, LRDM, and ZoomLDM? These methods are highly relevant to the paper’s main claim. Even if full reproduction is difficult, comparisons on a subset of resolutions, datasets, or metrics under a shared evaluation protocol would make the evidence much stronger.

  3. Since BigCell is conditioned on pathology foundation-model embeddings and is also evaluated partly using foundation-model similarity, can the authors discuss the possibility of metric bias? Are there any evaluations based on encoders, pathologist criteria, or other measures that are independent of the conditioning model family?

  4. For text-conditioned generation, the current method reaches 8192×8192 rather than full gigapixel resolution. Can the authors clarify whether the “gigapixel” claim applies only to reference-embedding-conditioned generation, and not to report-conditioned generation?

  5. The adaptive scheduling strategy is interesting, but I would like to understand its robustness. How sensitive is the selected fraction r across tissue types, organs, and staining variations? Does the same scheduling rule work reliably outside the test distribution?

Limitations

The authors already discuss several limitations, including the high generation cost and the fact that report-conditioned generation is currently limited to 8192×8192. I would encourage them to further expand this discussion in two directions. First, the paper should more explicitly acknowledge the limitation of its novelty claim relative to existing gigapixel WSI generation work. Second, it should discuss the possible dependence between foundation-model-based conditioning and foundation-model-based evaluation, since this may affect how some of the reported metrics should be interpreted.

Final justification

The rebuttal substantially strengthens the empirical evaluation, although my central novelty concern remains: the broad “first gigapixel WSI generation” claim is overstated, while the revised “native-resolution” claim narrows the scope of the contribution. Nevertheless, I recognize that gigapixel-scale WSI generation remains an important and underexplored research direction, and I believe BigCell represents meaningful progress through a strong system-level scaling and integration effort. I have therefore raised my score to 4.

Formatting concerns

n/a

4 comments
Authors · RebuttalOpenReview ↗
Rebuttal

W1: My main concern is that the paper overstates its novelty. The claim of being the first gigapixel WSI generation method needs to be more carefully qualified. Prior work, such as Harb et al. 2024, has already studied diffusion-based histopathology WSI generation at gigapixel scale, and DiffInfinite also targets arbitrarily large histopathology image synthesis with long-range structure...

Q1: Please clarify the “first” claim. In particular, how is BigCell different from Harb et al. 2024, which also studies gigapixel histopathology WSI generation? I would be more positive about the originality if the paper narrowed this claim and clearly explained the specific novelty of BigCell relative to prior gigapixel WSI generation methods.

Response:

Q1. Our claim is that BigCell is the first method to generate gigapixel whole-slide images at native resolution: the full-size canvas is denoised at 20×20 \times in all steps, and no stage of the pipeline upsamples a low-resolution/magnification version of the slide. Harb et al. [19] generated large WSIs by progressively super-resolving a 512×512 thumbnail. DiffInfinite [3] requires an additional segmentation mask that is not available readily at test time and is not shown to work for gigapixel-scales. We will update this claim in our abstract and Intro accordingly.

We point out that the central difference with the previous methodologies lies in how tissue is synthesized at the highest resolution. Harb et al. utilizes a pure super-resolution method that starts from a 512x512 thumbnail which it progressively upsamples. We pinpoint a central limitation to this approach: high-res tissue is guided only by the blurry pixels of the previous resolution which does not guarantee that regions that are far apart will be synthesized consistently.

DiffInfinite relies on a 40-class annotation mask to guide tissue synthesis. This coarse classification may work for the single cancer type and cohort that DiffInfinite trains on but is guaranteed to fail as soon as it moves to more complex datasets. The synthesized tissue images in far away regions are independent of each other and only rely on the conditioning signal from the 40-class per-pixel mask to be consistent. One likely failure mode of this would be staining -- which is not encoded in the 40 classes -- and could drastically change between two patches that are 20,000 pixels apart.

Our approach utilizes a dense embedding grid (1536-dim) as conditioning that (a) is very expressive, encoding substantially more information than blurry pixels and class labels and (b) ensures long-range consistency by utilizing either a reference image from which the embeddings are extracted from or the CGM model which is trained with a slide-wide receptive field to provide the conditioning.

W2: The comparison set is also not complete enough. The paper compares with PixCell, CytoSyn, and MuPaD, which is useful for evaluating the tile generator. However, it does not include direct quantitative comparisons with several highly relevant large-image or WSI-scale methods, especially Harb et al., DiffInfinite, LRDM, and ZoomLDM...

Q2: Can the authors provide more direct comparisons with Harb et al., DiffInfinite, LRDM, and ZoomLDM? These methods are highly relevant to the paper’s main claim. Even if full reproduction is difficult, comparisons on a subset of resolutions, datasets, or metrics under a shared evaluation protocol would make the evidence much stronger.

Response: We agree that these comparisons would greatly strengthen our paper. Unfortunately, Harb et al [19] releases neither the code nor trained models, and DiffInfinite [3] checkpoint links are not available, so neither of these can be evaluated on our data. LRDM [16] and ZoomLDM [49] have public checkpoints, which we run at 8192×81928192 \times 8192 on the same 100 held-out ROIs as Table 1.

Method TITAN MOOZY V2meanV2_{mean} H1meanH1_{mean} V2FDV2_{FD} H1FDH1_{FD}
BigCell 0.956 0.973 0.869 0.735 907 621
PixCell 0.941 0.900 0.778 0.667 1023 696
CytoSyn 0.929 0.864 0.753 0.640 895 604
ZoomLDM 0.708 0.801 0.646 0.477 815 553
LRDM 0.531 0.693 0.513 0.395 731 502

BigCell leads every paired metric by a wide margin, at both patch and slide level: TITAN 0.956 against 0.708 for ZoomLDM and 0.531 for LRDM, and V2meanV2_{mean} 0.869 against 0.646 and 0.513.

BigCell ranks third on Fréchet distance. FD is computed on 256×256256 \times 256 crops and does not measure agreement with the conditioning; LRDM attains the best FD while obtaining the lowest agreement with the reference slide.

W3. The evaluation is fairly broad, but some of the metrics rely heavily on foundation-model similarity. These metrics are useful, but they may also favor methods that use related foundation-model embeddings as conditioning. The paper should discuss more clearly whether the evaluation is sufficiently independent from the conditioning representation.

Q3. Since BigCell is conditioned on pathology foundation-model embeddings and is also evaluated partly using foundation-model similarity, can the authors discuss the possibility of metric bias? Are there any evaluations based on encoders, pathologist criteria, or other measures that are independent of the conditioning model family?

In our experiments, we deliberately avoid evaluating with the conditioning encoder – conditioning uses UNI-2 [10], while our metrics use Virchow-2 [52], H-optimus-1 [7], MOOZY [23] and TITAN [12].

To further address the concern, we ran an additional evaluation at 8k scale that moves the measurement out of embedding space altogether. Instead of comparing latent representations, we process each slide using a medical VLM to generate a report, and compare the decoded text.

Setup: For each of the 100 matched real/synthetic 8k pairs, we generate a structured report with MedGemma-4B, a general-purpose medical VLM that is not pathology-specific. Patching follows the high-dimensional pathology notebook released with the model. Each slide is presented in a single turn with a fixed template the model must fill:

TISSUE OF ORIGIN: <one organ>
MALIGNANT: <yes or no>
DIAGNOSIS: <one most likely specific diagnosis>
Method Same organ Same diagnosis All three fields
BigCell 69% 46% 41%
PixCell 63% 42% 38%
CytoSyn 54% 26% 25%
ZoomLDM 61% 40% 36%
LRDM 59% 31% 30%

All methods are run on identical ROIs, so these rates are meaningful relative to one another rather than in absolute terms. BigCell leads on all three fields.

Q4: For text-conditioned generation, the current method reaches 8192×8192 rather than full gigapixel resolution. Can the authors clarify whether the “gigapixel” claim applies only to reference-embedding-conditioned generation, and not to report-conditioned generation?

Response: Yes. The gigapixel claim applies to reference-conditioned generation; text-conditioned generation is demonstrated at 8192×81928192 \times 8192. We will state this explicitly in the abstract and contribution (3). We want to emphasize that the limit is data, not method. Our pipeline is text -> conditioning grid -> image, and the image generation stage scales up to 32,768×32,76832,768 \times 32,768 regardless of where the grid comes from. The CGM's output grid is fixed at 8k, because training it requires paired report-WSI data. Our dataset yields 500k 8k regions, and scaling the CGM is a question of assembling a larger paired corpus.

Q5: The adaptive scheduling strategy is interesting, but I would like to understand its robustness. How sensitive is the selected fraction r across tissue types, organs, and staining variations?

Response: We thank the reviewer for this question. We ran a stratified analysis of our existing 32k generations.

TITAN similarity to the real slide

stratum n r=0.05 r=0.09 r=0.25 r=0.41 r=1.0 (full)
By source
HistAI 108 0.744 0.865 0.953 0.963 0.967
TCGA (FFPE) 78 0.805 0.913 0.970 0.975 0.978
GTEx (normal) 35 0.822 0.915 0.975 0.979 0.981
CPTAC 18 0.717 0.872 0.954 0.966 0.967
NLST 10 0.783 0.876 0.956 0.964 0.968
TCGA (frozen) 7 0.691 0.849 0.947 0.953 0.961
By organ
GI tract 47 0.748 0.877 0.959 0.967 0.971
Thoracic 39 0.743 0.875 0.952 0.961 0.964
Gynaecologic 38 0.811 0.901 0.966 0.973 0.977
Genitourinary 32 0.817 0.912 0.975 0.979 0.983
Breast 28 0.735 0.874 0.954 0.966 0.966
Endocrine 18 0.799 0.908 0.969 0.974 0.973
Skin 17 0.750 0.856 0.958 0.964 0.968
Soft tissue 13 0.804 0.916 0.972 0.976 0.978
CNS 9 0.731 0.869 0.946 0.955 0.964
Liver/Pancreas 7 0.823 0.920 0.977 0.980 0.983
Head/Neck 5 0.755 0.862 0.964 0.969 0.974
Lymphoid 2 0.729 0.868 0.955 0.965 0.965
Other 1 0.735 0.833 0.921 0.944 0.944
By stain
H&E 245 0.777 0.891 0.962 0.969 0.972
IHC 11 0.667 0.808 0.945 0.960 0.965
All images 256 0.772 0.888 0.962 0.969 0.972

At the operating point r = 0.25, every setting lies within 0.02 of its full-compute value. Variance is concentrated at very low r, where IHC (n = 11) and frozen TCGA (n = 7) degrade more than H&E; both recover by r = 0.25. We will add this table to the appendix.

Sellergren, Andrew, et al. "Medgemma 1.5 technical report." arXiv preprint arXiv:2604.05081 (2026).

Reviewer MKSc · CommentOpenReview ↗

I thank the authors for the substantial additional experiments and clarifications. The new comparisons with LRDM and ZoomLDM, the MedGemma-based evaluation, and the stratified analysis of the scheduling strategy considerably strengthen the empirical evaluation. The clarification that report-conditioned generation is currently limited to 8K resolution also resolves my concern about the scope of the gigapixel claim.

However, my central concern regarding novelty remains. In the rebuttal, the authors substantially narrow the original “first gigapixel WSI generation” claim. BigCell is now positioned more specifically as the first method to denoise a final-resolution latent canvas without progressively super-resolving a lower-resolution thumbnail. This revision is appropriate and captures a meaningful technical distinction from Harb et al. At the same time, it indicates that the defensible novelty is considerably narrower than suggested by the original framing. The broader problem of gigapixel WSI generation had already been addressed by prior work, with Harb et al. demonstrating outputs up to 65,536 × 65,536. The remaining distinction therefore concerns a particular generation and scaling strategy rather than the introduction of gigapixel WSI generation itself.

More broadly, BigCell is trained at 2,048 × 2,048 resolution and scales to gigapixel outputs through an LRDM-style sliding-window procedure. Several other core components, including dense foundation-model conditioning, progressive-resolution training, representation-guided large-image synthesis, and text-to-embedding-grid generation, also have close precedents in PixCell and LRDM. BigCell’s main advances therefore appear to be scaling these components to substantially higher resolutions and introducing a practical CFG-based adaptive window scheduling strategy.

I appreciate the authors’ commitment to revising the novelty claims accordingly. The rebuttal substantially improves the experimental completeness of the paper, and I recognize the value of the resulting large-scale system. Nevertheless, the contribution supported by the revised framing is substantially more limited than the original “first gigapixel WSI generator” claim suggested. I therefore view the work primarily as a well-executed system-level scaling and integration effort rather than a fundamentally new generative framework, and I maintain my score.

Authors · CommentOpenReview ↗

We thank the reviewer for the response. We address the remaining concern on novelty.

The reviewer's position is that Harb et al. [19] already addressed gigapixel WSI generation, so what remains is the scaling strategy. Our argument is that Harb et al. do not sample a gigapixel image, but instead sample a 512x512 image and upscale it. Their pipeline draws from a learned distribution over WSIs exactly once, at the thumbnail level. Every subsequent stage is a conditional refinement that receives a local blurred crop of the stage below. Fine-scale content in two distant regions is therefore conditionally independent given the thumbnail, and no dependency can exist at 20x that is not already expressible at 512x512.

This is the crux of our claim. The properties that define a slide at 20x -- mitotic figures, gland formation, the stromal reaction at a tumor border -- are not present in a thumbnail and cannot be recovered from one. Their pipeline outputs 65,536x65,536, but does so by filling the remainder with locally plausible texture. The reviewer is correct that Harb et al. produce gigapixel outputs; a bicubic upsampler produces them too. Our claim is that no method has yet sampled a slide natively at gigapixel scale.

BigCell denoises the full latent canvas under a dense conditioning grid, aggregating per-window velocities into one global velocity field at every step. Every region is denoised at 20x at every step, thereby sampling the gigapixel image. The same grid specifies morphology at 20x everywhere on the canvas, which is what makes text-conditioned synthesis at 8192x8192 possible.

Regarding Pixcell and LRDM: both methods use similar frameworks (FM embedding conditioning + sliding-window generation) but neither is able to produce a realistic gigapixel sample as we show in our experiments. We use such models as a starting point and ask the following question: "What are the necessary changes to allow scaling SoTA pathology generative models to gigapixel resolutions?". This question is important as the field moves towards whole-slide foundation models [12,39,23,46], which are much closer to how human experts interact with pathology slides.

To achieve this scaling, we first find that the base tile generation model needs to be scaled up to 2048x2048 pixel resolution, and importantly further scaling to 4096x4096 starts showing diminishing returns. After establishing the base model's resolution empirically, we address generation speed. We introduce a selection strategy to reduce the sampling time by 3x, which in the context of hours/slide we argue is a significant improvement. Finally, to address controllability, we show that the CGM can be scaled in parallel to the tile model. The CGM's slide-wide receptive field allows control with slide-level reports, and we demonstrate the utility of our generated images in the data augmentation task of Section 3.5.

Overall, we believe that our work makes important steps towards scaling the top-performing generative models in digital histopathology to gigapixel-scales. We will release our models and training code which constitute the first baseline for gigapixel-scale generation.

Reviewer MKSc · CommentOpenReview ↗

Score Update After Discussion

Thank you for the detailed clarification. Although I still view the methodological novelty as relatively limited, gigapixel-scale WSI generation remains an important and underexplored research direction, and I believe efforts that make meaningful progress in this area deserve support; I have therefore raised my score to 4.

Reviewer 3zbPOpenReview ↗
Rating
4/6
Confidence
3/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

BigCell is presented as the first method to synthesize coherent gigapixel whole-slide images (up to 32,768×32,768). An 830M SiT flow-matching transformer generates 2048×2048 tiles conditioned via cross-attention on a dense grid of UNI-2 foundation-model embeddings, trained progressively from 256 to 2048 px on ~120k public WSIs. To exceed native resolution, the authors extend the MultiDiffusion/LRDM sliding-window scheme to flow matching and add an adaptive schedule using CFG magnitude as per-window importance. A separate model (CGM) generates UNI grids directly from report text, enabling text-to-image synthesis at 8k. Evaluation covers decoupled tile- and slide-level FM similarity, a board-certified pathologist study, and few-shot augmentation gains on PANDA and TCGA-UT-8K.

Strengths and weaknesses

Originality / Significance. The problem framing is novel and well-motivated: prior generators saturate well below slide scale (PixCell 1024/4096, ZoomLDM 4096), and the one prior gigapixel attempt super-resolves a thumbnail and hallucinates fine detail. Conditioning on a dense FM-embedding "blueprint" cleanly enforces local-global consistency, and being first to show text-to-pathology at 8k with a concrete downstream use case gives clear significance. Related-work positioning is fair.

Quality. Decoupling local fidelity (Virchow-2/H-Optimus, including the 5th-percentile tail) from global coherence (TITAN/MOOZY) is a thoughtful evaluation design, and reporting tail statistics plus paired Wilcoxon tests, a held-out report set, board-certified readers, and public-only data with code release adds rigor.

Weakness 1 — baseline confound. Table 1 compares BigCell-tile (2048 native) against baselines at much lower native resolutions (1024/512/224). Since Appendix E.1 shows fidelity rises with native resolution, the comparison conflates the proposed design with resolution. A resolution-matched baseline is needed to support the "outperforms prior generators" claim.

Weakness 2 — metric circularity. Conditioning and evaluation both live in pathology-FM space, so high similarity may reflect faithful reproduction of the conditioning grid rather than biological validity. The 32k coherence claim rests only on FM metrics and qualitative figures; the human study was at 8k, not slide scale.

Weakness 3 — human study. Only three readers, who were team members (IRB N/A for that reason), risks bias. The indistinguishability argument leans on κ≈0.02, but at-chance agreement can reflect task ambiguity rather than convincing fakes, and the 66% vs 55% gap lacks a significance test.

Questions

Can you add a resolution-matched (2048-native) baseline to isolate your design from native-resolution effects? A lead under matched resolution would raise my Quality score.

Can you provide an encoder-independent assessment of long-range structure at 32k (e.g., pathologist reading of full slides), given the current reliance on FM metrics?

Limitations

Adequately and honestly addressed: Section 6 notes the 8k cap on text conditioning, and Broader Impacts notes dataset bias and research-only use. Two items deserve explicit mention: the baseline-resolution confound and the FM-metric circularity. A sentence on misinformation risk specific to synthetic medical images would also help. Overall a good-faith treatment.

Formatting concerns

no

2 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We respond to the reviewer's weaknesses (W) below

W1: baseline confound. Table 1 compares BigCell-tile (2048 native) against baselines at much lower native resolutions (1024/512/224). Since Appendix E.1 shows fidelity rises with native resolution, the comparison conflates the proposed design with resolution. A resolution-matched baseline is needed to support the "outperforms prior generators" claim.

Response: We thank the reviewer for this suggestion. We agree that Table 1 does not disentangle architecture from native resolution. We address this with two experiments -- one already in the submission and one new.

(i) Matched native resolution: Our progressive training strategy produces a 1024-native BigCell model, evaluated for 8192×81928192 \times 8192 px generation in Figure 6. Here, we compare it with PixCell-1024:

Method TITAN MOOZY V2meanV2_{mean} H1meanH1_{mean} V2FDV2_{FD} H1FDH1_{FD}
BigCell-1024 0.952 0.971 0.849 0.723 912 617
PixCell-1024 0.941 0.900 0.778 0.667 1023 696

At identical native resolution and identical inference, BigCell leads on every slide- and patch-level metric.

(ii) Matched native resolution, data, and compute: We train a 2048-native model that keeps our backbone (SiT-XL, Flux-2 VAE latent), training data, and sampler fixed, and replaces our dense embedding-based conditioning with ZoomLDM's summarizer-based conditioning [49] under the same training budget as BigCell-2048. We train on fixed-size tiles at five magnifications (20×−1.25×20 \times - 1.25 \times). We then use ZoomLDM's joint sampling algorithm to synthesize 8192×81928192 \times 8192 at 20×20 \times with a 2048×20482048 \times 2048 guide at 5x.

Method Resolution TITAN MOOZY V2meanV2_{mean} H1meanH1_{mean} V2FDV2_{FD} H1FDH1_{FD}
BigCell 2048 0.956 0.973 0.869 0.735 907 621
BigCell-summarizer 2048 0.926 0.868 0.627 0.505 1229 813
PixCell-1024 1024 0.941 0.900 0.778 0.667 1023 696
CytoSyn 224 0.929 0.864 0.753 0.640 895 604

The summarizer-conditioned model at 2048 underperforms not just BigCell, but also PixCell-1024 on every metric. We attribute this to ZoomLDM's pooling of conditioning grids to a fixed 64×153664 \times 1536 budget: at 2048 native, a 20×20 \times tile (corresponding to a 2048×20482048 \times 2048 region), a 5×5 \times tile (8192×81928192 \times 8192 region), and a 1.25×1.25 \times image (32768×3276832768 \times 32768 region) are all conditioned with a 64×153664 \times 1536 grid. We believe this is the bottleneck when scaling ZoomLDM in resolution and warrants further dedicated experiments to investigate.

W2: metric circularity. Conditioning and evaluation both live in pathology-FM space, so high similarity may reflect faithful reproduction of the conditioning grid rather than biological validity. The 32k coherence claim rests only on FM metrics and qualitative figures; the human study was at 8k, not slide scale

Response: We agree with the reviewer on this point. Using pathology-FM embeddings for both conditioning and evaluation leaves open whether our metrics reward faithful reproduction of the UNI-2 grid instead of diagnostic content.

We first note that evaluating generative models with vision encoders is standard practice: text-to-image models conditioned on CLIP text embeddings are routinely scored with CLIPScore. In general, any large-scale evaluation of generative performance will rely on some automated metric, which in most cases is itself using a foundation-scale image encoder.

However, we do agree that training and evaluating with the same encoder can be problematic. In our experiments, we deliberately avoid evaluating with the conditioning encoder -- conditioning uses UNI-2 [10], while our metrics use Virchow-2 [52], H-optimus-1 [7], MOOZY [23] and TITAN [12].

To further address the concern, we ran an additional evaluation at 32k scale that moves the measurement out of embedding space altogether. Instead of comparing latent representations, we process each slide using a medical VLM to generate a report, and compare the decoded text.

Setup: For each of the 256 matched real/synthetic 32k pairs, we generate a structured report with MedGemma-4B, a general-purpose medical VLM. MedGemma-4B is not a pathology foundation model, shares no training pipeline with UNI-2 or with our evaluation encoders, and outputs text rather than an embedding, so this comparison never enters representation space.

Patching follows the high-dimensional pathology notebook released with the model. Each slide is presented in a single turn with a fixed template the model must fill:

TISSUE OF ORIGIN: <one organ>
MALIGNANT: <yes or no>
DIAGNOSIS: <one most likely specific diagnosis>
Real vs. Synthetic Chance
Same tissue of origin 85.9% [81.1, 89.6] 9.1% [7.7, 10.7]
Same diagnosis 72.2% [66.4, 77.3] 9.2% [7.4, 11.1]
All three identical 71.0% [65.1, 76.2] 6.0% [4.6, 7.7]

Chance is the rate at which a real report matches the synthetic report of a different slide, averaged over all such pairings; 95% Wilson intervals in brackets.

This shows that our 32k generations carry the diagnostic content of the tissue they are conditioned on.

W3: human study. Only three readers, who were team members (IRB N/A for that reason), risks bias. The indistinguishability argument leans on κ≈0.02, but at-chance agreement can reflect task ambiguity rather than convincing fakes, and the 66% vs 55% gap lacks a significance test.

Response:

κ≈0.02. The reviewer is right that near-zero agreement is uninformative in isolation, as an ambiguous task could produce it. Our study contained the control that distinguishes these, which we now report.

The same three pathologists, on the same images, agreed strongly on the patient-matching task (κ=0.66\kappa = 0.66, permutation p<1e−4p < 1e-4) while agreeing at chance on real-vs-synthetic (κ=0.02\kappa = 0.02). This shows that the at-chance agreement reflects the absence of a detectable signal, not an ambiguous task.

66% vs 55% gap. We now test this gap directly. Keeping every pathologist's answers same, we randomly permuted the 50 real and 50 synthetic labels across the 100 trials and recomputed the gap, 10,000 times. This preserves each pathologist's own tendency to answer "real". Overall detection accuracy is 55.3% (95% CI 50–61%), consistent with chance and bounded below 61%, and the gap does not reach significance (p = 0.070). Pathologists therefore did not reliably distinguish BigCell outputs from real tissue.

On the reader panel. Our readers were board-certified pathologists who were team members. Recruiting external readers requires IRB review that can not be completed within this discussion period. We will state this explicitly in the camera-ready.

We will expand Section 6 to note the relationship between foundation-model conditioning and foundation-model evaluation, and Broader Impacts will note the misinformation risk specific to synthetic medical images. The resolution confound is addressed directly by the matched comparisons above, which we will add to the appendix and reference from the Table 1 caption.

Sellergren, Andrew, et al. "Medgemma 1.5 technical report." arXiv preprint arXiv:2604.05081 (2026).

Reviewer 3zbP · CommentOpenReview ↗

Thank you for the detailed rebuttal, which has addressed most of my concerns. After also reviewing the discussions from the other reviewers, I have decided to maintain my original rating.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Missing a submission?