potentialpaper

Rethinking Contrastive Targets in Radiology Language-Image Pretraining

Yunhe Gao, Ashwin Kumar, Jiaming Liu, Chong Wang, Maya Varma, Fuying Wang, Stefania L Moroianu, Louisa Fay, Sergios Gatidis, Akshay S Chaudhari, Curtis Langlotz

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

TL;DR. We identify the failure of medical CLIP as a structural mismatch between its paired-identity target and the shared-schema fact-bundle structure of radiology data, and correct it with fact-compatibility targets.

Abstract. CLIP-style contrastive image--text pretraining is widely used in radiology data, where each image is paired with one report and every other report in the batch is treated as a negative. Under this recipe, two failures appear, neither systematically addressed by existing contrastive learning theory: zero-shot evaluation peaks then degrades while training loss keeps decreasing, and training fails to learn at all at large batches. We hypothesize the cause is structural rather than radiology-specific: many unpaired reports share clinical findings with a given image, so CLIP's paired-identity target is systematically biased, not merely noisy. To test this, we construct CLEVR-Radiology, a synthetic testbed that preserves only this overlapping-fact structure and reproduces both failures. With evidence that the structure is sufficient to reproduce the failures, we develop a target-misspecification theory that derives both failures from a single deterministic gradient bias amplified by batch size, and use it to motivate a minimal compatibility-based correction, CorLIP: a text is treated as positive whenever its clinical assertions agree with the image, with no other change to the training pipeline. Beyond benchmark improvements, CorLIP removes the post-peak degradation, makes large-batch training succeed where it previously collapsed, substantially amplifies the gains from more data, and is the only configuration that remains stable up to B=2048. The correction also transfers from chest X-ray to 3D CT modalities.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
16 Apr 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:49 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

This paper identifies two failure modes of CLIP-style radiology vision-language pretraining, attributes them to a mismatch between paired-identity contrastive targets and the shared semantic structure of radiology reports, and proposes CorLIP, a compatibility-based target that treats clinically compatible reports as positives. The paper combines theoretical analysis, a synthetic benchmark, and extensive experiments on chest X-ray and CT datasets to support its claims.

-----------------Initial Meta-review-----------------

The reviewers appreciated the clear progression from empirical observations to theoretical analysis and a simple correction. They found the synthetic CLEVR-Radiology benchmark useful for isolating the proposed mechanism, and considered the compatibility-based objective an effective and practical modification that consistently improves stability and zero-shot performance.

The main concerns from the reviewers and this AC include:

First, the paper should better position its novelty with respect to existing work on false negatives, multi-positive contrastive learning, and related approaches that address imperfect contrastive targets.

Second, the dependence of CorLIP on the chosen compatibility schema deserves further discussion, including how schema design affects downstream performance and the generality of the learned representations.

Third, while the empirical results are strong, additional analysis of generalization beyond chest radiology, the CT experiments, and the practical cost of the compatibility preprocessing would further strengthen the paper.

Fourth, although the theoretical analysis of the proposed failure mechanism is interesting and well motivated, the proposed correction appears somewhat heuristic. CorLIP relies on a manually designed compatibility schema extracted from reports, and the results depend on the chosen schema.

Fifth, The evidence supporting the generality of the proposed diagnosis is somewhat limited. The two optimization phenomena are directly demonstrated on only a single real chest X-ray dataset (MIMIC-CXR) and reproduced on the synthetic CLEVR-Radiology benchmark. It remains unclear whether the same phenomena also occur on other real CXR datasets or 3D CT. In addition, although the paper states that the proposed correction transfers to 3D CT, I could not locate the corresponding quantitative results in the manuscript.

Please address the following points in the rebuttal:

(1) Please clarify the novelty of the proposed diagnosis and correction relative to existing work on false negatives, multi-positive contrastive learning, and related target-correction methods.

(2) Please clarify how the choice of compatibility schema affects the learned representations and downstream performance, and discuss the generality of the proposed compatibility formulation.

(3) Please discuss the generality of the proposed diagnosis. In particular, are the reported optimization phenomena observed beyond MIMIC-CXR (e.g., on other CXR datasets or CT), and please clarify the missing quantitative results for the claimed CT transfer experiment.

---------------Final Meta-review-----------------

I have reviewed the authors' rebuttal, the discussion, and the reviewers' final assessments. The rebuttal substantially addresses the main concerns raised in the initial meta-review. The authors better position the contribution relative to prior work on false negatives and multi-positive contrastive learning, clarify the role and practical cost of the compatibility schema, and provide additional evidence supporting the proposed diagnosis, including results on 3D CT. The reviewers responded positively to these clarifications, with the final assessments supporting acceptance.

Some limitations remain, particularly regarding the dependence on the choice of compatibility schema and the generality of the learned representations to downstream tasks beyond those evaluated. However, the authors have appropriately clarified and narrowed their claims, and I do not consider these remaining limitations to outweigh the paper's strengths. Overall, the paper provides a well-motivated analysis of an important failure mode in radiology vision-language pretraining, supported by theoretical analysis, controlled synthetic experiments, and extensive real-data evaluation. I therefore recommend accepting the paper.

Final justification

I have reviewed the authors' rebuttal, the discussion, and the reviewers' final assessments. The rebuttal substantially addresses the main concerns raised in the initial meta-review. The authors better position the contribution relative to prior work on false negatives and multi-positive contrastive learning, clarify the role and practical cost of the compatibility schema, and provide additional evidence supporting the proposed diagnosis, including results on 3D CT. The reviewers responded positively to these clarifications, with the final assessments supporting acceptance.

Some limitations remain, particularly regarding the dependence on the choice of compatibility schema and the generality of the learned representations to downstream tasks beyond those evaluated. However, the authors have appropriately clarified and narrowed their claims, and I do not consider these remaining limitations to outweigh the paper's strengths. Overall, the paper provides a well-motivated analysis of an important failure mode in radiology vision-language pretraining, supported by theoretical analysis, controlled synthetic experiments, and extensive real-data evaluation. I therefore recommend accepting the paper.

Area Chair K9F8 · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

This paper identifies two failure modes of CLIP-style radiology vision-language pretraining, attributes them to a mismatch between paired-identity contrastive targets and the shared semantic structure of radiology reports, and proposes CorLIP, a compatibility-based target that treats clinically compatible reports as positives. The paper combines theoretical analysis, a synthetic benchmark, and extensive experiments on chest X-ray and CT datasets to support its claims.

-----------------Initial Meta-review-----------------

The reviewers appreciated the clear progression from empirical observations to theoretical analysis and a simple correction. They found the synthetic CLEVR-Radiology benchmark useful for isolating the proposed mechanism, and considered the compatibility-based objective an effective and practical modification that consistently improves stability and zero-shot performance.

The main concerns from the reviewers and this AC include:

First, the paper should better position its novelty with respect to existing work on false negatives, multi-positive contrastive learning, and related approaches that address imperfect contrastive targets.

Second, the dependence of CorLIP on the chosen compatibility schema deserves further discussion, including how schema design affects downstream performance and the generality of the learned representations.

Third, while the empirical results are strong, additional analysis of generalization beyond chest radiology, the CT experiments, and the practical cost of the compatibility preprocessing would further strengthen the paper.

Fourth, although the theoretical analysis of the proposed failure mechanism is interesting and well motivated, the proposed correction appears somewhat heuristic. CorLIP relies on a manually designed compatibility schema extracted from reports, and the results depend on the chosen schema.

Fifth, The evidence supporting the generality of the proposed diagnosis is somewhat limited. The two optimization phenomena are directly demonstrated on only a single real chest X-ray dataset (MIMIC-CXR) and reproduced on the synthetic CLEVR-Radiology benchmark. It remains unclear whether the same phenomena also occur on other real CXR datasets or 3D CT. In addition, although the paper states that the proposed correction transfers to 3D CT, I could not locate the corresponding quantitative results in the manuscript.

Please address the following points in the rebuttal:

(1) Please clarify the novelty of the proposed diagnosis and correction relative to existing work on false negatives, multi-positive contrastive learning, and related target-correction methods.

(2) Please clarify how the choice of compatibility schema affects the learned representations and downstream performance, and discuss the generality of the proposed compatibility formulation.

(3) Please discuss the generality of the proposed diagnosis. In particular, are the reported optimization phenomena observed beyond MIMIC-CXR (e.g., on other CXR datasets or CT), and please clarify the missing quantitative results for the claimed CT transfer experiment.

---------------Final Meta-review-----------------

I have reviewed the authors' rebuttal, the discussion, and the reviewers' final assessments. The rebuttal substantially addresses the main concerns raised in the initial meta-review. The authors better position the contribution relative to prior work on false negatives and multi-positive contrastive learning, clarify the role and practical cost of the compatibility schema, and provide additional evidence supporting the proposed diagnosis, including results on 3D CT. The reviewers responded positively to these clarifications, with the final assessments supporting acceptance.

Some limitations remain, particularly regarding the dependence on the choice of compatibility schema and the generality of the learned representations to downstream tasks beyond those evaluated. However, the authors have appropriately clarified and narrowed their claims, and I do not consider these remaining limitations to outweigh the paper's strengths. Overall, the paper provides a well-motivated analysis of an important failure mode in radiology vision-language pretraining, supported by theoretical analysis, controlled synthetic experiments, and extensive real-data evaluation. I therefore recommend accepting the paper.

Final justification

I have reviewed the authors' rebuttal, the discussion, and the reviewers' final assessments. The rebuttal substantially addresses the main concerns raised in the initial meta-review. The authors better position the contribution relative to prior work on false negatives and multi-positive contrastive learning, clarify the role and practical cost of the compatibility schema, and provide additional evidence supporting the proposed diagnosis, including results on 3D CT. The reviewers responded positively to these clarifications, with the final assessments supporting acceptance.

Some limitations remain, particularly regarding the dependence on the choice of compatibility schema and the generality of the learned representations to downstream tasks beyond those evaluated. However, the authors have appropriately clarified and narrowed their claims, and I do not consider these remaining limitations to outweigh the paper's strengths. Overall, the paper provides a well-motivated analysis of an important failure mode in radiology vision-language pretraining, supported by theoretical analysis, controlled synthetic experiments, and extensive real-data evaluation. I therefore recommend accepting the paper.

Reviewer eJifOpenReview ↗
Rating
4/6
Confidence
3/5
Quality
3/4
Clarity
3/4
Significance
2/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The paper looks at CLIP-style pre-training, focusing on Chest X-rays and radiology reports. Specifically, it focuses on the impact of semantically similar training samples being treated as negatives by the contrastive loss. The paper identifies two failure modes that are induced by this dynamic: a rise-then-fall behaviour in zero-shot classification performance as the number of training steps increases, and large batch collapse, where sufficiently large batch sizes prohibit generalization. The authors make a theoretical argument that these behaviours can be attributed to a target misspecification as opposed to standard overfitting. They verify this with experiments on MIMIC-CXR as well as on CLEVR-Radiology, a novel controlled testbed. These results motivate their new pre-training objective, CorLIP, which does not treat semantically compatible images and texts from distinct samples as negatives. Finally, the authors include experiments where the proposed method outperforms Vanilla CLIP as well as related prior work on a collection of classification benchmarks.

Strengths and weaknesses

Strengths:

  • The problem is well motivated, as semantically similar pairs being treated as negatives is something that has been observed previously in Chest X-ray CLIP training, forcing adopters to limit the batch size.

  • The theory nicely quantifies why the Vanilla CLIP objective will limit cosine similarity between semantically similar samples. The paper shows that this is due to a misaligned target rather than general overfitting.

  • The construction of a testbed, CLEVR-Radiology, to test these training dynamics in a more controlled environment, seems like it could be genuinely useful for the community.

Weaknesses:

The importance of the relationship between the comparability schema and the downstream classification task is understated. My main concern has to do with the implicit assumptions we make when we choose the compatibility kernel. Essentially, the choice of this kernel determines how we cluster images in representation space (by avoiding pushing compatible images and texts apart). The implication is that for strong zero-shot performance we should choose a kernel that aligns well with the downstream classification task. The paper acknowledges this somewhat by discussing how different granularities can be useful for different tasks, but I think this goes beyond that. It seems to me that CorLIP approaches supervised clustering (with labels extracted from reports), while maintaining the textual semantics (allowing for zero-shot classification), which could potentially be useful in certain settings. My worry, however, is that this method optimizes for zero-shot classification on specific tasks, which could come at the cost of generality, since much work in this domain evaluates representations on additional tasks such as facilitating better supervised learning, segmentation, and modality transfer [1, 2].

For example, we only see CorLIP outperforming prior work on MIMIC-CXR when using ChexBert-13d (which aligns nearly one-to-one with the MIMIC labels) to extract compatibility scores. On VinDr, the best configuration switches to the finer MedGemma-30d schema, not because it matches VinDr's labels (it does not), but because its finer granularity avoids collapsing distinctions that the coarse schema merges. That the optimal schema changes with the evaluation is the concern: schema choice is doing task-specific work.

Clarity of experiments. Secondly, I think the paper would benefit from clarity on several points.

  • Due to the concerns discussed above, I think it would be fair to include the label spaces of all datasets that the paper evaluates on. Furthermore, while the latent fact states are included in the appendix, clustering will also be determined by the prompt given to MedGemma-30d, so this should likely be included as well.
  • I think the paper would benefit from being more precise about the exact classification and projection heads used. Are these both linear layers, or are any of them MLPs? And perhaps more importantly, are the backbones completely fine-tuned in all experiments, or are any parts frozen? This is important for the discussion of the different behaviours observed in Section 2 to ensure that both the supervised and CLIP models are equally expressive (which would have an impact on generic overfitting).
  • On a similar note, is the text projection / backbone fine-tuned as well?

Minor comments:

  • Line 282 says that Figure 3 shows Vanilla CLIP evaluation, but I can't seem to find it.
  • The "Data scaling helps more when it scales the right target." paragraph (line 292) only references results in the appendix, somewhat detracting from the flow of the paper.
  • Since CorLIP essentially allows for clustering of semantically similar samples, it could be good to include some visualizations of this.

References:

[1] Zhou et al., (2026). A multimodal vision–language model for generalizable annotation-free pathology localization. Nature Biomedical Engineering, 1-15.

[2] Huang et al., (2021). Gloria: A multimodal global-local representation learning framework for label-efficient medical image recognition. In Proceedings of the IEEE/CVF international conference on computer vision (pp. 3942-3951).

Questions
  • Have the authors thought about comparing these results against text-supervised clustering? I.e., extract clusters from the reports but don't align with them, and instead apply supervised contrastive learning between images [3]. This would, of course, forfeit open-vocabulary zero-shot inference, so it is not a drop-in replacement, but it could be worth comparing the representations extracted from both. Is there a reason to believe this would perform worse? The similarity between CorLIP and this setup is alluded to in Appendix A.4.
  • Could the authors please clarify the experimental details asked about above?
  • If I understand correctly, all of the values in the decomposition in Lemma 1 are realizable during training (q^i∗\hat{q}_i^*, piθp_i^{\theta}, eie_i​). Do the authors think it would be useful to include a plot of these values?

[3] Khosla et al., (2020). Supervised contrastive learning. Advances in neural information processing systems, 33, 18661-18673.

Limitations

Unfortunately, I find the scope of the work to be quite limited. As discussed above, my understanding is that the paper essentially optimizes for zero-shot classification, and even then, there is a need to choose an appropriate schema for the downstream classification task. The benefit of this method could be strengthened by comparing against standard supervised clustering (where the clusters have been extracted from the texts).

Final justification

My original review raised concerns regarding

  • the clarity of some experimental details,
  • the scope of the paper, and the potential overlap with classic supervised contrastive learning,
  • the understated importance of the choice of comparability schema.

The author's rebuttal addressed many of these concerns by including the requested experimental details and a thorough discussion positioning the paper in relation to standard supervised contrastive learning, including additional experiments comparing against the SupCon baseline.

Some concerns remained, namely:

  • The impact of the choice of compatibility schema is still not completely understood, and the fact that MedGemma-30d beats CheXbert-13d on CheXpert (even though the label spaces of the latter should align perfectly) means that it could be difficult to construct these schemas using expert knowledge.
  • Whether or not CorLIP could lead to worse performance on alternative downstream tasks (e.g., report generation or supervised fine-tuning) remained underexplored since the paper mainly evaluates on zero-shot classification.

Still, after discussion with the authors, I believe the current contribution is acceptable as is, given that these limitations are properly raised in the final version of the manuscript.

Formatting concerns

None

7 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We thank the reviewer for the careful reading, and are glad the review finds the problem well motivated, agrees the theory correctly attributes the failure to target misalignment rather than overfitting, and sees CLEVR-Radiology as useful to the community. We clarify each concern below.

1. Scope and positioning.

We respectfully clarify that our contribution is not an optimization for zero-shot classification, in two respects.

Why this problem matters. Radiology data is generated with paired images and reports in routine clinical care, making image–text contrastive learning one of the most widely adopted approaches for radiology representation learning. Major works across X-ray [2–7], CT [8, 9], and MRI [10] all build on the CLIP-style contrastive recipe. Yet practitioners routinely encounter unexplained failures, such as performance degradation during training and instability at larger batch sizes, and prior work has responded with heuristic fixes without a unified diagnosis. Our paper fills this gap: it identifies the structural root cause, explains both failure modes from a single mechanism, and derives a minimal correction. The scope is the contrastive learning objective and radiology data pretraining, not a single downstream task.

What we evaluate, and why. Zero-shot classification is one probe here, not the objective being optimized. Our evaluation answers the two questions central to a pretraining objective. (i) Representation quality. In-domain classification (Table 1), OOD classification on two external label spaces (Table 2), and dense phrase grounding on MS-CXR (Table 2), which is localization rather than classification. (ii) Scaling stability. Trajectory stability from B=16 to B=2048 (Figures 1, 3, 4), data scaling (Table 3), generality across loss families (CLIP and SigLIP, Figure 8), and transfer to another modality and encoder family (CXR to 3D CT, Section 5). This is what the heuristic fixes leave unresolved, and what matters most for pretraining at scale.

2. Comparison Against Supervised Learning

We group these concepts, since the distinction from each defines CorLIP's position.

Multi-label supervised learning is already our baseline. Training the vision encoder directly on report-extracted labels is the red dashed curve in Figures 1 and 3, using the CheXpert 14-class labels released with MIMIC-CXR, themselves derived from the reports, on the same backbone, data, augmentations, and schedule (Appendix E.1, L972-977). This is precisely "clusters extracted from the texts." Vanilla CLIP peaks well below it (0.68 vs 0.748), while sentence-level CorLIP exceeds it. The comparison is informative in one direction: label supervision cannot perform open-vocabulary or zero-shot inference at all, so exceeding it while retaining cross-modal alignment shows contrastive learning recovers its advantage once positives are correctly defined.

Supervised contrastive learning. In SupCon [41], the label set exhaustively defines the semantic space: samples sharing a label are positives, all others negatives, and no distinction outside the label list can be learned. A multi-label extension is still bounded by that predefined space. CorLIP is related to a multi-label, cross-modal variant of SupCon but is not reducible to it. Within the schema's coverage, extracted facts identify which off-diagonal cells are false negatives and correct the target. Outside the coverage, standard CLIP mechanics operate unchanged, and the text encoder still trains end-to-end on all textual content. The schema denoises the target rather than bounding what the model can represent, which is why open-vocabulary inference survives. Two further differences: our positives are defined by entailment rather than class equivalence or embedding similarity, and radiology compatibility is directional and per-assertion, since two sentences entailed by the same image may assert unrelated facts and are not interchangeable positives.

Image-only SupCon. This lies largely outside our scope, since it removes the image-text objective under study, and with no text encoder there is no zero-shot capability, so only linear probing is comparable. We ran it as a reference point for the bound described above. Following the reviewer's suggestion, we trained a vision encoder alone with multi-label SupCon, positives defined by MIMIC-CXR's 14 report-extracted labels, on the same backbone, data, augmentations, and schedule, evaluated by linear probe. In domain on MIMIC-CXR, where the evaluation label space is the one its positives came from, it reaches 80.3 mean AUC, close to the 81.6 CorLIP-CB sentence obtains zero-shot. On OOD VinDr, whose 28 labels it never saw, it falls to 76.3, below uncorrected vanilla CLIP at 83.1 and more than 10 points below CorLIP-MG sentence at 87.3, despite its probe being fitted on VinDr's own training split while the CLIP results are zero-shot. This is the drawback made concrete: the fixed labels exhaustively define what the model can represent, so distinctions outside them are collapsed rather than left unsupervised, and with no text side there is no route to an unseen label space. CorLIP corrects the target only inside the schema's coverage and leaves standard CLIP mechanics intact outside it, so open-vocabulary generalization is preserved.

3. Schema Granularity

We agree granularity matters, but it does not require per-task tuning. The choice reduces to two cases, neither involving tuning against an evaluation.

When the downstream label space is known, matching the correction schema to it during pretraining simply uses information already in hand, and is the better choice. On MIMIC, CheXbert-13d reaches 81.6 mean AUC at sentence level, above the strongest prior method at 78.9.

When it is not known, which is the general case, the finer schema is uniformly better and can be fixed in advance. MedGemma-30d beats CheXbert-13d on CheXpert, VinDr, and MS-CXR at all three text granularities, nine of nine, while CheXbert-13d wins MIMIC at all three. The split follows granularity rather than the individual evaluation. Under this single fixed configuration, CorLIP-MG sentence beats every prior method on all three: 86.6 vs 83.5 on CheXpert, 87.3 vs 84.1 on VinDr, and 41.6 vs 35.8 on MS-CXR grounding. This is why MedGemma-30d is already the paper's stated default (L246), as the less benchmark-coupled option.

Correction itself does not depend on the choice: across all six extractor by granularity combinations, CorLIP improves over vanilla CLIP on every evaluation (Table 4).

4. Relationship to GLoRIA and AFLoc

Methodological orthogonality. GLoRIA adds a local contrastive objective on top of CLIP's global contrastive loss, and AFLoc extends this to three alignment levels. Both keep paired-identity targets in every branch, so the misspecification we identify is present in their global term exactly as in vanilla CLIP, untouched by the local objectives they contribute. Their axis is the alignment architecture; ours is the target these objectives are trained against. The two are complementary rather than alternative. Following the reviewer's comment we verified this directly with two experiments: (1) original GLoRIA, and (2) GLoRIA with the local branch untouched and the global-branch target replaced by CorLIP-CB compatibility. MIMIC mean AUC improves from 69.1 to 78.8, confirming that CorLIP's contribution is orthogonal to local contrastive methods.

Evaluation breadth. Because our contribution is at the level of the target, our evaluation is organized around the properties a pretraining objective should have, and is thorough in that respect. Beyond in-domain and OOD classification, it covers dense phrase grounding on MS-CXR, trajectory stability across batch sizes from 16 to 2048, data-scaling efficiency from 60K to 120K studies, generality across contrastive loss families with CLIP and SigLIP, and transfer to a different modality and encoder family with 3D CT.

5. Experimental Details

Controlled comparison. Per Appendix E.1, all methods share the same DINOv3 ViT-B/16 image encoder, BioClinicalBERT text encoder, data, augmentations, optimizer, and schedule. CorLIP changes only the target matrix. Projection heads are standard CLIP linear layers; the supervised head is an MLP. Both vision and text backbones are fully fine-tuned end-to-end in all experiments.

Dataset label spaces. MIMIC-CXR and CheXpert share the same 14-class space: Atelectasis, Cardiomegaly, Consolidation, Edema, Enlarged Cardiomediastinum, Fracture, Lung Lesion, Lung Opacity, No Finding, Pleural Effusion, Pleural Other, Pneumonia, Pneumothorax, Support Devices. VinDr uses a 28-class vocabulary: Aortic Enlargement, Atelectasis, Calcification, Cardiomegaly, Clavicle Fracture, Consolidation, COPD, Edema, Emphysema, Enlarged PA, ILD, Infiltration, Lung Cavity, Lung Cyst, Lung Opacity, Lung Tumor, Mediastinal Shift, Nodule/Mass, No Finding, Other Diseases, Other Lesion, Pleural Effusion, Pleural Thickening, Pneumonia, Pneumothorax, Pulmonary Fibrosis, Rib Fracture, Tuberculosis. VinDr's 28 labels do not align with MedGemma-30d's 30 slots (Table 5, Appendix C.1): they differ in granularity, laterality, and category boundaries. MedGemma-30d's stronger VinDr result (Table 4) therefore reflects finer correction preserving clinical distinctions, not schema–evaluation alignment.

MedGemma-30d prompt. Will be added to the appendix; space here is limited.

6. Minor Comments Line 282 / Figure 3: Will correct the reference. Data scaling (line 292): It's hard to add to main text due to the limited space. Embedding visualizations: Will add t-SNE plots comparing vanilla CLIP and CorLIP clusters. Lemma 1 decomposition plot (Q3): Feasible on CLEVR-Radiology where fact states are available. Will include ‖d_sem‖ and ‖d_id‖ over training in the revision.

Reviewer eJif · CommentOpenReview ↗

I thank the authors for their thorough rebuttal, including extensive additional motivation and useful experimental results.

Several things have been made clearer:

  • (2.) I greatly appreciate the effort the authors have expended in including these experiments and these results mostly address my concerns. I agree that there is a large difference between standard SupCon and contrastive image-text pre-training, but given the grouping CorLIP imposes based on the schema, I believe it would be reasonable to include a discussion in the Appendix (similar to the one the rebuttal provided) clearly differentiating these methods.

  • (5.) The experimental details clearly strengthen the experiments presented in the paper.


Still, some of my concerns persist.

  • (3.) The discussion around this does not fully resolve my concerns. First off I'm not sure that the results in the paper support the claim that “When the downstream label space is known, matching the correction schema to it during pretraining simply uses information already in hand, and is the better choice”. For instance, MedGemma-30d beats CheXbert-13d on CheXpert, even though that should be a case where the labels match exactly. Additionally, since only two schemas are evaluated, the claim that a more granular schema is uniformly better for OOD could be a bit overstated. I imagine that there is a limit to how granular you would want your schema to be, and the provided schemas differ not only in their label spaces but also in their extraction methods. The labels for MIMIC were extracted by the rule-based CheXpert Labeler [5] (which was used to train the CheXbert model leveraged by CorLIP-CB), while the CheXpert test set was annotated by radiologists [6], making schema/class labeling agreement a plausible explanation.

  • (1. & 4.) I’m familiar with the CLIP radiology literature and acknowledge that this general form of pre-training is useful for much more than zero-shot classification. My comment was more in regards to CorLIP’s main contribution, which allows the representation of different images to become more similar as long as they fall within the same pre-defined category (based on the schema). I think the inclusion of the phrase grounding experiment is good, but it is still quite similar to the ‘’standard’’ zero-shot classification task compared to other more diverse tasks. The main difference is that phrase grounding evaluates the similarity of local representations against a single phrase (which usually refers to a common finding that the schema could potentially incorporate, see Figure 3 in [4]), as opposed to the pooled embeddings against a small vocabulary. This is a good evaluation of the local features, but it still probes the same image-text similarity, unlike tasks such as fine-tuning the image encoder for a specific classification/segmentation, or generating new reports. These tasks were what my original GLoRIA and AFLoc comment was referring to, not their proposed methodologies (I agree with the authors that the axes are orthogonal). My main concern is this: as I hope the authors also would agree, CorLIP does not only resolve a training dynamic issue, it also encourages clustering of images and texts that fall within the same schematic category. This can be very useful as evidenced by the classification performance presented in the paper. Still, a 30-finding schema is coarse relative to the full content of radiology reports, so it is plausible that removing the incentive to distinguish images that agree on all schema-covered findings but differ in content could discard information that more fine-grained tasks depend on. Since I don't think it's reasonable to ask you to run excessive experiments in these domains within the discussion, could the authors motivate why they believe that this would not be a concern?

All in all, I greatly appreciate the effort put in by the authors, and the rebuttal has improved my assessment of the paper. Concern 3. is the most practical one, and I do believe that some of the claims made regarding the choice of schema are not supported enough (e.g., the matched schema performs worse on CheXpert, granularity is not the only thing that makes the schemas different). Regarding my comments on points 1. & 4., it's not that I believe that a method has to excel at everything, but I do think there's value in acknowledging and somewhat probing potential limitations, trying to see if there is a drawback, something that I think the paper could have done more of.

References:

[4] Boecking et al. Making the Most of Text Semantics to Improve Biomedical Vision–Language Processing, ECCV, 2022 [5] Johnson et al. MIMIC-CXR-JPG, a large publicly available database of labeled chest radiographs, arXiv, 2019 [6] Irvin et al. CheXpert: A Large Chest Radiograph Dataset with Uncertainty Labels and Expert Comparison, AAAI, 2019

Authors · CommentOpenReview ↗

Reply to the follow up comments

We sincerely thank the reviewer for this thoughtful follow-up. We are glad that the additional experiments and clarifications were helpful. In the revision, we will incorporate the rebuttal’s discussion of our positioning, including the relationship to SupCon and related concepts, into the Related Work and Appendix.

The reviewer’s remaining observation highlights an important distinction between the general compatibility-correction principle and the invariances induced by a particular schema. Our previous statement about granularity can be made more precise. We find that the concerns in Points 3 and 1&4 can be understood through the same schema trade-off.

A schema that is too coarse can produce over-correction: it declares two cases compatible even though they differ in clinically relevant information omitted by the schema. For example, CheXbert-13d does not represent laterality, so an image with a left-sided finding may receive positive target mass for a sentence describing the corresponding right-sided finding. This removes an incentive to preserve a distinction that localization or other fine-grained tasks may require. Pushed to the extreme, such invariance could suppress clinically useful within-finding distinctions.

Conversely, making a flat schema increasingly fine can make the correction too sparse. Suppose precise localization is represented using mutually exclusive atomic categories. Right upper lobe pneumonia and right lower lobe pneumonia should remain distinct at the location specific level, but a flat kernel has no mechanism to also express that they share the higher level concept of pneumonia. It therefore preserves the distinction while losing supervision for their shared clinical structure. In the extreme, if every detailed combination of finding, location, and severity defines a separate category, the compatible set can approach only the paired sample, reducing the correction toward vanilla CLIP’s paired identity target.

This perspective also helps explain Point 3. On MIMIC, CorLIP-CB’s correction target and the evaluation labels are closely aligned: both originate from the same CheXpert-labeling pipeline and therefore share similar category boundaries, omissions, and annotation conventions. Consequently, distinctions discarded by CheXbert-13d, such as laterality or finer finding subtypes, are often also invisible to the in-domain evaluation. The resulting coarse invariance is therefore not strongly penalized and can even be advantageous by concentrating the representation on exactly the distinctions measured by the MIMIC labels.

CheXpert has the same nominal output categories, but not necessarily the same semantic partition of the data: its test labels are expert annotations, its images come from a different institution, and its subtype and visual distributions may differ. Under this shift, distinctions treated as irrelevant by the coarse MIMIC-aligned schema may become useful intermediate features for recognizing the same final categories robustly. MedGemma-30d preserves more of this clinical structure, which provides a plausible explanation for why CorLIP-MG transfers better to CheXpert despite the shared label vocabulary. The reviewer’s explanation based on annotation provenance is therefore complementary: nominal label-space agreement does not guarantee agreement between the correction-induced invariances and the distinctions used by an expert-labeled OOD evaluation.

Accordingly, we will replace the universal claim with the narrower empirical observation that, among the two schemas evaluated, MedGemma 30d is the stronger fixed default across the three held out evaluations, whereas CheXbert 13d performs better on MIMIC. We will not interpret this as evidence that label space matching or increasing granularity is universally optimal.

Reviewer D7wgOpenReview ↗
Rating
5/6
Confidence
4/5
Quality
3/4
Clarity
4/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

Authors propose a modified contrastive learning framework for medical vision-language pretraining that addresses the limitation of treating all unpaired reports as negatives. The paper argues that standard CLIP objectives are systematically biased because multiple reports may share compatible clinical findings with the same image. The authors first reproduce this issue using a synthetic benchmark (CLEVR-Radiology), develop a theoretical analysis linking target misspecification to optimization failures, and then propose a compatibility-based contrastive objective that considers clinically compatible reports as positives. Experiments are conducted on synthetic data, chest X-ray datasets, and 3D CT data. Results show improved benchmark performance, elimination of post-peak degradation, successful large-batch training (up to batch size 2048), and better scaling with additional data compared to standard CLIP training. Additional analyses include synthetic experiments validating the proposed hypothesis and the transfer of the proposed correction across imaging modalities.

Strengths and weaknesses

Strengths:

  • The paper identifies a real and important issue in medical vision-language contrastive learning, where visually similar images may correspond to compatible clinical findings despite different image-report pairings.
  • I particularly liked the overall narrative of the paper: diagnosing a practical optimization issue, formulating a clear hypothesis, supporting it with theoretical analysis, and proposing a simple correction. The progression from hypothesis to theory to experiments is convincing.
  • The proposed method is simple and integrates naturally into existing CLIP-style pipelines.
  • The theoretical analysis appears sound and is well supported by synthetic and real-data experiments.

Weaknesses:

  • Some claims regarding the novelty of the identified problem could be better positioned with respect to existing work on false negatives, multi-positive contrastive learning, and hard negative selection.
  • Several experimental aspects could be further analyzed to strengthen the paper, particularly regarding the role of the pretrained encoder, preprocessing cost, and generalization beyond chest radiology.
  • The transfer experiment to CT remains relatively limited, considering the broader claims.
Questions

Questions:

  • The paper frames this issue as largely overlooked. While the proposed diagnosis and theoretical treatment appear novel, the broader problem of incorrect positive/negative assignment in contrastive learning is well known (e.g., false negatives, multi-positive CL). Could the authors better position their work within this literature and clarify what is fundamentally new?
  • The paper demonstrates stable training up to a batch size of 2048. Is this value simply the largest feasible batch under available compute, or is there another reason for selecting this limit? It would be interesting to know whether the observed behavior continues beyond this regime.
  • CLEVR-Radiology is useful as a controlled synthetic benchmark to validate the proposed hypothesis. However, its usefulness beyond this paper is less clear. If the authors consider it a main contribution, could they better motivate why it should become a community benchmark rather than simply serving as a synthetic validation tool?
  • The paper argues that compatibility rather than paired identity should define positives. Could the authors provide additional qualitative and quantitative evidence of this issue directly in the real datasets? For example, retrieving nearest neighbors under standard CLIP and showing clinically compatible yet incorrectly treated negatives would further support the motivation.
  • The method likely depends on the pretrained visual encoder used for retrieval. Would the same issue arise if the encoder were trained directly for diagnosis rather than generic image-text alignment? More generally, how does the proposed compatibility score compare to standard embedding similarity used in vanilla CLIP?
  • Could the authors discuss how CorLIP relates to multi-label learning? One alternative could be to extract structured findings from reports and directly train using those labels. Understanding the connection between these approaches would better position the contribution.
  • The current experiments focus primarily on chest radiology. The transfer experiment to CT is encouraging but limited. Could the authors discuss whether the proposed issue would remain as severe when training on much more diverse medical datasets (multiple organs, modalities, and report types), where semantic diversity is substantially larger?
  • Could the authors report the computational cost of the additional preprocessing required to compute compatibility labels? This would help assess the practical overhead of CorLIP.
  • One possible explanation for the observed optimization failure is that medical image-report spaces have relatively low semantic diversity compared to natural image-text datasets. In natural CLIP, the probability that another sample in the batch is semantically compatible with the anchor is extremely small, even for very large batches, whereas in chest radiology many reports legitimately share the same findings. Could the authors discuss this perspective more explicitly? In the paper's notation, this would correspond to the probability that m_i>1 is much larger in medical imaging.
Limitations

Yes.

Final justification

Authors address an interesting and practically relevant problem in medical vision-language pretraining. The rebuttal better positions the work within the existing literature, clarifies the methodology, and provides additional analyses that strengthen the paper's empirical evidence. I would therefore increase my overall rating to 5. Accept score.

Formatting concerns

None.

3 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We thank the reviewer for the careful reading and constructive questions. We are encouraged that the reviewer finds the paper identifies "a real and important issue," considers the hypothesis-to-theory-to-experiment progression "convincing," recognizes the theoretical analysis as "sound and well supported," and rates the clarity as "excellent." We address each question below.

W1, Q1, Q6: Positioning and related concepts

Prior medical VLP work has observed the false-negative issue and proposed heuristic mitigations [18, 19, 25]. We do not claim to be the first to notice it. Our positioning is: systematic diagnosis → theoretical analysis → theory-grounded minimal correction. We do not claim CorLIP is the optimal fix; we aim to provide the community with insights into why the standard recipe fails and how to correct it.

Comparison with existing corrections. In general-domain CL, false-negative corrections (e.g., Debiased CL [39]) treat false negatives as rare stochastic collisions. Our theory (Propositions 1–2) shows that in radiology this problem is far more severe: the low-dimensional, normal-dominant fact space makes compatible collisions structural and dense (ω ≫ 0), producing deterministic failures (rise-then-fall and large-batch collapse) absent in general-domain settings. Within medical VLP, prior work (MedCLIP [18], SAT [25], Ko & Park [19]) observes the problem and proposes heuristic mitigations, but does not systematically characterize the failure mode or explain why it arises. Our gradient decomposition (Lemma 1) fills this gap. Additionally, these methods define positives via similarity (embedding distance or label overlap), whereas CorLIP uses entailment, i.e., whether the text's asserted facts are satisfied by the image's fact state, a more principled target when the goal is encoding fact states.

Relationship to multi-positive CL and multi-label learning. Sentence-level CorLIP has structural affinity with multi-label, multi-positive CL: multi-label because an image has a multi-dimensional finding state, multi-positive because any text correctly describing a finding should be positive, and the same finding admits many surface forms. But CorLIP cannot be reduced to multi-positive SupCon [41]. In SupCon, the label set exhaustively defines the semantic space. In contrast, CorLIP corrects the target within the schema-covered finding space; outside the schema, standard CLIP mechanics still operate. This hybrid structure is why CorLIP retains open-vocabulary and zero-shot capabilities beyond the correction schema. Multi-label supervised learning (Q6: train the vision encoder with extracted labels) is actually presented as our baseline in Figures 1&3, red dashed line. Supervised multi-label training cannot perform open-vocabulary or zero-shot tasks. CorLIP surpasses it on fixed-label evaluation while retaining all of CLIP's open-vocab advantages, showing that contrastive learning's cross-modal structure is an advantage once positives are correctly defined. Finally, the report vs. impression vs. sentence comparison is not just an ablation: it demonstrates that the unit of contrast matters. Report-level correction compresses multiple facts into a lossy scalar and still fails at large batch; sentence-level correction approaches atomic assertions where multi-positive structure is cleanest.

Hard negative selection. Naively mining hard negatives is potentially harmful in radiology contrastive learning: the "hardest" unpaired texts (highest similarity to anchor) are often precisely the false negatives. They are similar because they describe the same findings. Mining them amplifies the identity residual's wrong direction. CorLIP takes the opposite path: correcting positive definitions enables large-batch training, and large batches naturally supply more genuinely incompatible texts as true hard negatives. Figure 4(B) confirms this: batch scaling improves performance under corrected targets.

Q2: Why B=2048. B=2048 is the gpu memory limit of our 8×H100 80G setup; we do not have the resources to scale further. Moreover, Figure 4(B) already shows saturation: peak AUC plateaus at B=512 and remains flat or dips slightly through 1024 and 2048, suggesting that additional batch size would not yield further gains.

Q3: CLEVR-Radiology. We do not position CLEVR-Radiology as a real-data benchmark replacement. Its contribution is methodological: "strip domain-specific confounders → formulate structural hypothesis → verify under controlled conditions." This is valuable in medical AI, where real-data ablations cannot disentangle data structure from clinical language complexity, annotation noise, or the lack of true ground truth. We will release the data and full generation pipeline, which can be adapted to other tasks, enabling controlled hypothesis testing beyond contrastive learning. We believe this methodology, common in NLP and vision but rare in medical VLP, deserves broader adoption.

Q4: Direct evidence of false negatives on real data. We measured sentence-level false-negative counts directly on MIMIC-CXR by sampling 1000 real training batches for batch size 128 and 1024, with compatibility defined by CheXbert-13d. Some examples:

Anchor #FNs per batch, B=128 #FNs per batch, B=1024 % of off-diag, B=128/1024
"no lung opacity" (absent) 84.9 ± 1.2 686.3 ± 4.6 66.8 / 67.1
"lung opacity" (present) 13.7 ± 0.1 111.2 ± 0.4 10.8 / 10.9
"fracture" (present, rare) 2.1 ± 0.1 17.2 ± 0.1 1.6 / 1.7

Radiology reports describe findings both positively and negatively, so false negatives arise in both directions: at B=128, a "no lung opacity" statement has ~85 false negative images per batch, "lung opacity" has ~14. Even Fracture, a rare finding, averages 2.1 false negatives per batch, and since the learning signal for rare findings is already weak, these carry disproportionate impact. Full per-finding breakdowns will be added in revision. We will also add the qualitative counterpart the reviewer suggests using retrieval.

Q5. We want to clarify that CorLIP's compatibility targets are constructed entirely from text parsing, with no dependence on any visual encoder or retrieval. CheXbert or MedGemma parses the report text into structured fact vectors; the compatibility matrix is computed by comparing these text-derived vectors. No image embeddings are involved. Supervised training with labels derived from text does not have this issue, since there is no contrast between samples: label supervision never asks two images with the same findings to be separated. Compatibility versus similarity. The similarity computation is unchanged from vanilla CLIP: image and text embeddings, cosine similarity, temperature scaling, symmetric cross entropy. The only modification is the target. Vanilla CLIP uses the identity matrix, treating a text as positive only for the image it was paired with. CorLIP replaces this with a compatibility matrix, in which a text is positive for any image whose fact state entails its assertions, and then row and column normalizes it into a distribution. Similarity is the model's prediction; compatibility is the supervision it is trained toward. Architecture, encoders, optimizer, and batch construction are untouched.

Q7: Would the issue persist on more diverse corpora? Yes, and CT is our first data point. Merlin-30d spans multi-organs in lower thorax, abdomen and pelvic with a different modality and report style than CXR, and the pattern holds (Section 5, L326–332; setup in Appendix E.3): full-report vanilla reaches 0.679 mean AUC, sentence-level vanilla 0.758, and sentence-level CorLIP 0.793 over 30 findings. We also observe O1 there: report-level vanilla peaks and then degrades while the training loss keeps decreasing. We will move these into a table and expand Appendix E.3 in the revision.

Additionally, statements of normalcy and negation dominate radiology reporting across organs and modalities, and they remain compatible with a large fraction of studies however diverse the corpus is. For specific findings, compatible texts reappear as soon as enough studies in a batch share a fact state, which larger batches make unavoidable, and these are the hardest negatives and therefore the most damaging to push apart.

Q8: Preprocessing cost. Appendix C (L771–775) reports the cost. On a single H100 80G: CheXbert processes 120K reports in under 30 minutes; MedGemma-27B with vLLM processes the same pool in ~1.5 hours. This is a one-time offline cost, adding zero overhead during training or evaluation, and is small relative to contrastive pretraining (typically tens to hundreds of GPU-hours).

Q9: Low semantic diversity perspective. We agree, and this is what ω captures in Proposition 2; the measurements in Q4 quantify it on real MIMIC-CXR batches. We would sharpen the contrast. General vision-language data has no fixed frame of reference: the space of possible contents is open-ended and two images may share almost nothing, so compatibility is vanishingly rare at any batch size. Radiology is the opposite. However diverse a corpus becomes, every study is variance within the same anatomical schema, each region taking a finding state from a small clinical vocabulary, and each report bundling many such assertions. This is the shared-schema fact-bundle structure named in Section 1, and it is what keeps ω far from zero. Because findings are asserted as either present or absent, a large fraction of unpaired texts stays compatible with many images, so the rate stays high rather than thinning with scale.

Reviewer D7wg · CommentOpenReview ↗

answer to rebuttal

Thank you for the thorough rebuttal.

Authors addressed most of my concerns, and the additional real-data analysis of false negatives in MIMIC-CXR provides additional support for the paper’s central hypothesis. The improved positioning relative to existing contrastive learning approaches, along with clarifications on compatibility and semantic diversity, further strengthen the paper.

Authors · CommentOpenReview ↗

We sincerely thank the reviewer for the positive assessment and for recognizing the value of our additional analysis and clarifications. We are glad that the real-data false-negative analysis and the improved positioning helped strengthen the paper’s central motivation. We will incorporate these discussions and clarifications into the revised manuscript. We greatly appreciate your thoughtful feedback throughout the review process.

Reviewer 5k2SOpenReview ↗
Rating
5/6
Confidence
3/5
Quality
4/4
Clarity
4/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper addresses two failure modes observed when training CLIP-style models on radiology data: zero-shot performance can degrade after reaching a peak during training even while the training loss continues to decrease, and training can fail at large batch sizes. To isolate these from medical data confounders, they construct a synthetic testbed, and argue theoretically and empirically that both failures arise due to the fact that multiple reports can share the exact same semantics with the same image while vanilla CLIP only treats a single pair as the positive. They propose CorLIP as a minimal fix, which replaces the paired identity target in vanilla CLIP with an approximate compatibility target such that other clinically compatible texts are not treated as pure negatives. In practice, they estimate compatibility by parsing reports into structured assertion-level findings. On MIMIC-CXR and multiple OOD-datasets, they show that CorLIP stabilizes training and improves zero-shot performance over vanilla CLIP and established medical CLIP baselines.

Strengths and weaknesses

Strengths:

  • Very well-structured paper, with a clear flow from observations to theory to empirical validation. (quality, clarity)
  • The paper not only provides theoretical derivations, but also uses a well-constructed synthetic testbed where the observed failure modes align with theory, further showing that the problem is structural rather than specific to medical terminology. (quality, originality)
  • Simple but effective fix for the two main failures, leading to improved zero-shot performance and higher training stability on MIMIC-CXR. (quality, significance)
  • The authors also include results on three out-of-distribution datasets and further show that CorLIP transfers to 3D CT. (quality, significance)

Weaknesses:

  • The method might lose clinically important information in complex findings. Since compatibility is estimated through a parser, CorLIP is dependent on how fine-grained the extracted findings are, e.g. a more coarse parser might miss relevant details like severity or laterality. Interestingly, CorLIP shows quite a large decrease in zero-shot performance when using a finer schema. The authors also acknowledge this issue, and highlight that CorLIP improves upon vanilla CLIP in both cases. (quality, significance)
  • For report-level text (Table 1) CoRLIP performs worse than established medical CLIP baselines such as MedCLIP and 'Ko&Park'. (significance)
Questions
  1. Are the two failure modes (O1&O2) also observed in the 3D CT experiment? If yes, this would provide additional empirical evidence that these phenomena occur beyond just the MIMIC dataset in other real-word medical datasets.
  2. If feasible, could the authors provide the Ko&Park baseline (Table 1) for sentence-level texts? Since it already shows strong performance for report-level texts, it would be useful to know how it performs on sentence-level texts compared to CorLIP.
  3. Is there a particular reason why CorLIPs performance slightly decreases (instead of staying flat or even increasing) with high batch sizes (Figure 4)? This would provide deeper understanding of the underlying mechanism.
Limitations

yes

Final justification

The authors have reasonably addressed my remaining concerns during the rebuttal. I maintain my positive assessment and recommend acceptance.

Formatting concerns

no concerns

3 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We thank the reviewer for the careful reading and the positive assessment. We are encouraged that the review finds the flow from observation to theory to empirical validation clear, sees the synthetic testbed as evidence that the problem is structural rather than specific to medical terminology, and finds the correction a simple but effective fix for both failure modes, with the three OOD datasets and the 3D CT transfer supporting its generality.

Both weaknesses concern the same grid of results, which is currently split across Tables 1, 2 and 4 so that the in-domain MIMIC column reads as the headline. It is in fact not the whole story, and we consolidate everything here.

What the four evaluations measure. MIMIC-CXR is in-domain, our training distribution, and the label space CheXbert-13d corrections are derived from. The other three test other axes of the representation quality: CheXpert is the same label space under institutional domain shift, VinDr adds a finer 28-finding vocabulary that no correction schema matches, and MS-CXR uses bounding boxes to test dense localization rather than just classification.

Regrouped from Tables 1&2:

Text Method MIMIC (14) CheXpert (14) VinDr (28) MS-CXR (dense)
Rep. Vanilla 66.1 79.8 83.0 22.4
Rep. SAT 67.9 80.7 83.9 34.0
Rep. Ko&Park 78.9 83.5 84.1 35.8
Rep. CorLIP-CB 77.3 84.5 83.7 34.5
Rep. CorLIP-MG 74.1 86.2 87.3 36.9
Sen. Vanilla 68.2 82.1 83.1 30.7
Sen. MedCLIP 77.4 80.9 82.8 32.3
Sen. CorLIP-CB 81.6 85.6 83.7 37.7
Sen. CorLIP-MG 75.8 86.6 87.3 41.6

W1: Schema granularity.

The reviewer's mechanism is correct: CheXbert-13d cannot express laterality and merges findings that a finer schema would distinguish. However, the "performance decrease with a finer schema" is confined to MIMIC and reflects evaluation alignment rather than information loss.

MIMIC's zero-shot evaluation uses CheXpert-derived 14-class labels. CheXbert-13d correction shares exactly this label space, so the model fits it more easily. Once evaluation is no longer tied to training domain or CheXpert labels, the ordering reverses without exception: MedGemma-30d beats CheXbert-13d on CheXpert (same 14 classes, different institution), VinDr (28 findings), and MS-CXR (dense grounding), at every text granularity. Coarse correction wins only when the downstream evaluation aligns with it; elsewhere the additional clinical detail in the finer schema pays off consistently.

Because the finer schema is uniformly better on all OOD benchmarks, it can be fixed in advance (L246, set before any results) without per-task selection. And regardless of which schema is used, all 24 CorLIP cells in Table 4 improve upon vanilla CLIP, confirming that the correction itself is robust to schema choice.

W2: Report-level comparison with prior methods.

Ko&Park combines three distinct similarity sources (text embedding, CheXbert labels, and RadGraph) through per-stream thresholds. CorLIP changes only the target matrix; architecture, optimizer, and loss function are untouched. Even with this minimal intervention, CorLIP-MG at report level already outperforms Ko&Park on three of four benchmarks: CheXpert (86.2 vs 83.5), VinDr (87.3 vs 84.1), and MS-CXR (36.9 vs 35.8). Ko&Park leads only on MIMIC, which is the evaluation most aligned with CheXbert-based correction signals.

More importantly, our analysis shows that report level is not the optimal correction granularity. A bundled report compresses many fact-level agreements into a single scalar, which is inherently lossy (Prop. 3). This makes report level a weak operating point for entailment-based kernel. The theory-motivated solution is sentence-level correction, where each assertion is contrasted individually. At sentence level under the paper's fixed default (MedGemma-30d), CorLIP beats every baseline on CheXpert (86.6 vs 83.5), VinDr (87.3 vs 84.1), and MS-CXR (41.6 vs 35.8), with MIMIC the only exception. Both methods that lead there, Ko&Park and MedCLIP, derive their targets from CheXbert labels, so they share the alignment with the CheXpert-derived 14-class evaluation. Giving CorLIP the same alignment puts it ahead on MIMIC too (81.6 vs 78.9).

Moreover, CorLIP-MG sentence level is the only setting that is stable with large batch training up to batch size 2048. These results confirm the theoretical prediction: when the correction granularity matches the fact-bundle structure of the data, even a minimal entailment indicator is sufficient. We will make these comparisons clear in the revision.

A minor clarification: MedCLIP is evaluated at sentence level, and its semantic-matching targets are also built from CheXbert-extracted labels. The aligned comparison on MIMIC is therefore against CorLIP-CB, which is better on all four evaluations.

Q1: O1/O2 on 3D CT. We observe similar patterns on 3D CT data for O1. Report-level vanilla CLIP on Merlin peaks at 0.679 mean AUC across the 30 CT findings and then degrades to around 0.630 while the training loss keeps decreasing. We will add the CT trajectories in the revision.

Unfortunately, we can’t test O2. 3D volumes training requires significantly more gpu memory than 2D images. We can’t scale a large enough batch to test it.

Q2: Ko&Park at sentence level. We applied their method naively at sentence granularity, keeping the thresholds the same and changing only the text unit. It reaches 68.3 peak MIMIC AUC, at the level of uncorrected training, so the correction does not transfer as it stands.

We hypothesize that their method is similarity based and intra-modal, comparing the two texts in a pair, so with one randomly sampled sentence per study it compares two partial descriptions without aggregating over the report. Their thresholds are also absolute cutoffs selected at report granularity. We do not read this as evidence against their method, which performs well at report level. It suggests that moving such a kernel across text granularities needs dedicated adaptation and re-tuning, which is outside the scope of this paper.

Q3: why CorLIP dips slightly at very large batch. Peak AUC goes 71.1 (B=16) → 77.0 (B=512) → 76.0 (B=1024) → 75.7 (B=2048). We do not think this is specific to CorLIP or to radiology: general-domain contrastive training shows the same saturate-then-slightly-decline shape, just at much larger batch (e.g. SigLIP, Zhai et al. 2023, Fig. 2). Once the batch supplies enough genuinely distinct negatives, additional ones add little signal while making optimization harder, e.g. larger batches generally need more careful tuning, longer schedules or more tricks to make training stable. The contrast we want to draw is with vanilla, which does not saturate but collapses to chance; after correction, large batch goes from fatal to merely flat.

Reviewer 5k2S · CommentOpenReview ↗

I appreciate the authors’ rebuttal. It addressed my questions and concerns well. In particular, the authors clarified that fine-grained schemas perform better outside MIMIC, and that the apparent gains of CheXbert-based methods on MIMIC are largely due to alignment with CheXpert-derived evaluation labels. They also explain convincingly why sentence-level comparisons are more appropriate than report-level ones for their proposed correction. I maintain my positive assessment.

Authors · CommentOpenReview ↗

Thank you for your thoughtful feedback and continued positive assessment. We greatly appreciate it!

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Missing a submission?

Loading the discussion…