potentialpaper

MedIGen: Towards Reliable Medical Illustration Generation via Interleaved Introspective Reasoning

Rongsheng Wang, Hongru Zhou, Ruizhe Zhou, HAOMING CHEN, Zhenyang Cai, Junying Chen, Minghao Wu, Yaofei Duan, Ziyi Zeng, Benyou Wang

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

Abstract. Medical illustration generation is not merely domain-specific text-to-image (T2I) generation, but a high-constraint visual reasoning problem where visually plausible images can be invalid due to anatomical and structural errors. Existing T2I models largely rely on one-pass generation and lack an internal mechanism to inspect and correct such biomedical inconsistencies. We introduce MedIGen, a unified medical illustration generation model that transforms one-pass synthesis into an interleaved introspection-aware refinement process, coupling generation with self-reflection and re-generation through ``generate--reflect--refine'' cycles. MedIGen is trained through three progressive stages. First, we perform large-scale medical illustration pretraining on 1.21M samples. Second, we conduct mixture training over generation, reflection, and refinement sub-skills. Finally, we apply reinforcement learning with dual-level rewards that optimize both reasoning validity and final visual correctness. We further present IlluGenBench, an expert-aligned rubric-driven benchmark with 296 diverse tasks and 9,015 criteria, evaluating scientific accuracy, structural correctness, and semantic alignment beyond coarse visual plausibility. Experiments show that MedIGen substantially outperforms strong open-source unified and reasoning-based baselines, improving the medical reliability of generated illustrations and establishing a new open-source frontier. Data, code, and models are available at https://github.com/FreedomIntelligence/MedIGen.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
17 Apr 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:45 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

This paper introduces MedIGen, a unified model for medical illustration generation that replaces one-pass synthesis with an interleaved "generate-reflect-refine" reasoning process. Key strengths include a well-motivated problem addressing biomedical validity over mere visual plausibility, a comprehensive three-stage training pipeline, and the introduction of IlluGenBench, a rigorous rubric-driven evaluation benchmark. Despite its strong motivation and comprehensive evaluation resources, the reviewers raised several substantial concerns in the initial reviews that needed to be addressed:

  1. Limited novelty: The technical framework combines existing components, such as domain pretraining, generate-reflect-refine cycles, GRPO, and MLLM-based rewards, without introducing sufficiently distinct core methodologies, leading concerns that the work resembles a benchmark or dataset contribution rather than a novel core algorithmic advance.
  2. Potentially biased evaluation: The reliance on MLLM-as-judge frameworks and the authors' internally constructed benchmark introduces potential circularity, alignment biases, and shared vulnerabilities with the proposed generation methodology.
  3. Incomplete evaluation: The empirical study lacks stronger test-time and agent-based baselines, controlled ablations isolating the reflection text, and external validation datasets to prove generalization beyond the proposed benchmark.
  4. Overstated claims: The manuscript repeatedly emphasizes absolute "reliability," yet empirical results reveal persistent failure modes in disease illustrations, limited absolute score gains, and a significant bottleneck where the model frequently fails to correct errors even when they are successfully detected.

I have carefully read the authors' rebuttal and followed the subsequent reviewer discussions. The authors submitted a thorough rebuttal that successfully addressed the core issues raised by the reviewers.

To address the evaluation and baseline concerns, the authors provided extensive new experiments. This includes testing against stronger agent-based and test-time baselines, validating the model on an external benchmark (TechImage-Bench), and providing clear RL and reflection ablations. To mitigate the MLLM-as-judge bias, they incorporated an open-source judge (Qwen3.6-27B) and conducted convincing cross-judge and multi-run analyses. Additionally, the authors appropriately agreed to tone down the claims regarding absolute "reliability" to better reflect the current system's capabilities.

Although one reviewer noted that the method's reliance on unified multimodal models might limit its immediate application to stronger, specialist T2I diffusion models, the general consensus is that the proposed training paradigm and the IlluGenBench resource offer significant value to the community. Given the quality of the original submission and the strong rebuttal, I am glad to recommend this paper for acceptance.

Final justification

The authors provided a thorough rebuttal that resolved the main weaknesses identified in the initial reviews. They successfully demonstrated the robustness of their evaluation by adding an open-source judge and external benchmark tests, and they clarified the necessity of their training pipeline through new test-time baseline comparisons and RL ablations. All reviewers are satisfied with the revisions and agree that the proposed framework and the IlluGenBench benchmark are solid contributions to medical image generation.

Area Chair MEfg · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

This paper introduces MedIGen, a unified model for medical illustration generation that replaces one-pass synthesis with an interleaved "generate-reflect-refine" reasoning process. Key strengths include a well-motivated problem addressing biomedical validity over mere visual plausibility, a comprehensive three-stage training pipeline, and the introduction of IlluGenBench, a rigorous rubric-driven evaluation benchmark. Despite its strong motivation and comprehensive evaluation resources, the reviewers raised several substantial concerns in the initial reviews that needed to be addressed:

  1. Limited novelty: The technical framework combines existing components, such as domain pretraining, generate-reflect-refine cycles, GRPO, and MLLM-based rewards, without introducing sufficiently distinct core methodologies, leading concerns that the work resembles a benchmark or dataset contribution rather than a novel core algorithmic advance.
  2. Potentially biased evaluation: The reliance on MLLM-as-judge frameworks and the authors' internally constructed benchmark introduces potential circularity, alignment biases, and shared vulnerabilities with the proposed generation methodology.
  3. Incomplete evaluation: The empirical study lacks stronger test-time and agent-based baselines, controlled ablations isolating the reflection text, and external validation datasets to prove generalization beyond the proposed benchmark.
  4. Overstated claims: The manuscript repeatedly emphasizes absolute "reliability," yet empirical results reveal persistent failure modes in disease illustrations, limited absolute score gains, and a significant bottleneck where the model frequently fails to correct errors even when they are successfully detected.

I have carefully read the authors' rebuttal and followed the subsequent reviewer discussions. The authors submitted a thorough rebuttal that successfully addressed the core issues raised by the reviewers.

To address the evaluation and baseline concerns, the authors provided extensive new experiments. This includes testing against stronger agent-based and test-time baselines, validating the model on an external benchmark (TechImage-Bench), and providing clear RL and reflection ablations. To mitigate the MLLM-as-judge bias, they incorporated an open-source judge (Qwen3.6-27B) and conducted convincing cross-judge and multi-run analyses. Additionally, the authors appropriately agreed to tone down the claims regarding absolute "reliability" to better reflect the current system's capabilities.

Although one reviewer noted that the method's reliance on unified multimodal models might limit its immediate application to stronger, specialist T2I diffusion models, the general consensus is that the proposed training paradigm and the IlluGenBench resource offer significant value to the community. Given the quality of the original submission and the strong rebuttal, I am glad to recommend this paper for acceptance.

Final justification

The authors provided a thorough rebuttal that resolved the main weaknesses identified in the initial reviews. They successfully demonstrated the robustness of their evaluation by adding an open-source judge and external benchmark tests, and they clarified the necessity of their training pipeline through new test-time baseline comparisons and RL ablations. All reviewers are satisfied with the revisions and agree that the proposed framework and the IlluGenBench benchmark are solid contributions to medical image generation.

1 comment
Authors · CommentOpenReview ↗

Response to the Meta Review

We express our sincere gratitude to you and all the reviewers for the thorough and constructive feedback.

Rating changes:

Reviewer Initial Rating Post-rebuttal Rating Comment
pxiW 5 5 “I maintain my rating as accept.”
Xk7f 3 4 “I am inclined to raise my score to 4: Borderline Accept.”
iiC6 4 5 “so I suggest acceptance of the paper.”

During the rebuttal, we addressed the four key concerns:

  1. Limited novelty (Xk7f): We clarified that the central contribution is a training formulation that internalizes medical error diagnosis and correction into the generation policy. Controlled comparisons show that the gains cannot be explained by additional generation attempts or standard image-level RL alone.
  2. Potentially biased evaluation (pxiW, Xk7f, iiC6): We added the open-source Qwen3.6-27B judge, human-agreement and cross-judge analyses, repeated runs, and rubric robustness experiments. Different judges and rubric variants preserve the same model ranking.
  3. Incomplete evaluation (pxiW, Xk7f, iiC6): We added strong test-time and agent-based baselines, controlled reflection and RL ablations, external evaluation on TechImage-Bench, and transfer experiments on BAGEL, Qwen-Image-2512, and four frontier T2I models.
  4. Overstated claims (pxiW, iiC6): We will revise the title to “Toward Reliable Medical Illustration Generation ...” frame reliability as a comparative improvement rather than a deployment guarantee, and explicitly discuss the remaining diagnosis–correction bottleneck and limitations.

Overall, we are committed to polishing the paper. The revised manuscript will integrate all additional experiments from the rebuttal and incorporate all suggested revisions to improve the paper’s positioning, limitations, and future directions.

Finally, we reiterate our appreciation for the extensive supportive feedback.

Reviewer iiC6OpenReview ↗
Rating
5/6
Confidence
3/5
Quality
3/4
Clarity
4/4
Significance
4/4
Originality
4/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This work addresses medical illustration generation, arguing that this problem is not a simple text-to-image generation but a more complex reasoning task where visually plausible outputs may still contain anatomical or procedural errors. Authors introduce MedIGen, a unified multimodal (text + image) model built on Janus-Pro that replaces one-pass image generation with an interleaved refinement of the generated images through self-reflection. The model is trained through three stages: pretraining on 1.21 million medical illustration-caption pairs, supervised mixture training over generation, self-reflection, and re-generation skills, and GRPO-based reinforcement learning with dual-level rewards targeting both generation quality and image understandability. In addition, the authors introduce IlluGenBench, a benchmark containing 296 medical illustration tasks and 9,015 rubric criteria generated with GPT-5.1 and refined by experts. Experimental results show substantial improvements over a wide variety of open-source generation and reasoning models, with MedIGen achieving the best reported performance on IlluGenBench.

Strengths and weaknesses

The paper tackles an interesting problem, correctly identifying that visually convincing outputs may still be medically invalid, and the proposed introspective refinement framework is well thought of. The idea of explicitly coupling generation with self-reflection and corrective re-generation fits well with unified multimodal architectures. The three-stage training pipeline and the benchmark creation are equally significant and well-motivated, with IlluGenBench addressing an important evaluation gap by moving beyond generic text-image alignment metrics and introducing expert-guided rubric-based assessment focused on medical correctness. The empirical results are generally strong. MedIGen substantially outperforms its Janus-Pro base model and achieves large gains over other open-source baselines on the proposed benchmark despite not reaching the performances of commercial models. The stage-wise ablations support the value of each training component, while also presenting interesting results about failure cases, inference efficiency and cross-category analysis, supported by an extensive appendix. Authors also provide evidence that the model's main remaining bottleneck lies in converting identified errors into successful visual corrections rather than error detection itself. Several aspects, however, weaken the strength of the claims. Related to previous acknowledgment of the bottleneck, authors repeatedly emphasize reliable generation, but performance remains relatively weak on disease illustrations, with the expert audit showing that re-generation overall frequently fails even after successful error detection. Thus, the improvements are relative rather than robust medical correctness guarantees. Moreover, IlluGenBench, the rubric generation pipeline and the automatic evaluation protocol are all introduced by the authors. Although expert involvement is described and human agreement with the judge is analyzed, the paper remains dependent on an MLLM-as-judge framework and a benchmark construction process that may share biases with the proposed methodology. Independent validation on existing medical image-generation benchmarks or broader external evaluation would strengthen confidence in the reported gains. The contribution of the RL stage also appears limited in the main benchmark metric (+0.03 absolute improvement). While justified in the appendix, the main paper would benefit from a clearer demonstration that the dual-level reward design itself is necessary. Some other methodological details would also benefit from a stronger discussion, such as quality and diversity of the 150K supervised trajectories.

Questions

Additional evaluations on external benchmarks or datasets should be provided to demonstrate that the observed gains generalize beyond the proposed benchmark. Can the authors provide a stronger ablation comparing no RL, standard image-level RL and dual-level RL (proposed)? This would clarify whether the proposed reward decomposition is responsible for the gains. Is there a specific failure pattern over the failure cases for the disease images? Is there evidence that suggests that further reflection iterations would solve? Since GPT-5.1 is involved in generating captions and initial rubric criteria, how sensitive are benchmark results to rubric wording? I think the paper would benefit from proving that results are not overly dependent on benchmark generation.

Limitations

The authors discuss several limitations, including weaker performance on disease illustrations and the gap between error detection and successful correction, but the paper could more explicitly discuss limitations related to benchmark construction, dependence on the MLLM-as-judge framework and potential bias introduced by AI-assisted rubric generation. These should be acknowledged more clearly.

Final justification

The rebuttal addressed most of my concerns. Therefore, I believe with the proposed revisions the paper is ready for acceptance.

Formatting concerns

No major formatting, anonymity, or policy violations were observed. The paper appears compliant with standard submission requirements.

4 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We sincerely appreciate your valuable feedback. Below, we address each concern.


W1: authors repeatedly emphasize reliable generation, but performance remains relatively weak on disease illustrations, with the expert audit showing that re-generation overall frequently fails even after successful error detection. Thus, the improvements are relative rather than robust medical correctness guarantees.

AW1: We agree that the improvements are relative rather than robust medical correctness guarantees. We will revise the manuscript to clearly scope “reliability” to improved biomedical correctness and error correction under the evaluated benchmark settings.

  • Title. We will revise the wording to emphasize progress toward reliability rather than absolute reliability: “Toward Reliable Medical Illustration Generation.”
  • Abstract/Main text. We will replace statements that may imply fully reliable generation with more precise comparative wording: “improves the medical reliability of generated illustrations.”

W2 & Q1: Independent validation on existing medical image-generation benchmarks or broader external evaluation would strengthen confidence in the reported gains.

AW2&Q1: We additionally evaluate on the independently constructed Biology subset of TechImage-Bench [1] (318 tasks, 2,772 criteria). We follow its official evaluation and report Rubric Accuracy and Criterion Score.

Model Rubric Accuracy ↑ Criterion Score ↑
Janus-Pro-7B 0.548 0.251
Qwen-Image-2512 0.701 0.421
Gemini-3-Pro-Image 0.849 0.625
MedIGen 0.748 0.486

Observation. MedIGen improves substantially over Janus-Pro-7B and remains stronger than Qwen-Image-2512 on both metrics, while Gemini-3-Pro-Image remains the strongest model. This external evaluation shows that MedIGen's gains generalize beyond IlluGenBench.

References

[1] TechImage-Bench: Rubric-Based Evaluation for Technical Image Generation


W3: The contribution of the RL stage also appears limited in the main benchmark metric (+0.03 absolute improvement). While justified in the appendix, the main paper would benefit from a clearer demonstration that the dual-level reward design itself is necessary.

Answer: We agree that the improvement from Stage 2 SFT to Stage 3 RL is modest in the main benchmark metric. This is consistent with the intended role of Stage 3: it serves as a final refinement step on top of an already strong Stage-2 model, rather than the primary stage for acquiring medical knowledge.

To clarify whether the dual-level reward design is necessary, we add a controlled ablation. All settings use the same Stage-2 checkpoint, training data, evaluator, and optimization budget. Image-level RL uses only generation-quality rewards.

Setting Sci. Acc. Struct. Corr. Sem. Align. Avg.
No RL 0.5743 0.5082 0.6831 0.5885
Image-level RL 0.5833 0.5152 0.6893 0.5959
Dual-level RL 0.6064 0.5368 0.7111 0.6183

Observation. Image-level RL provides only a small gain over no RL (+0.0074 Avg.), whereas dual-level RL yields a larger additional improvement (+0.0224 Avg.) across all three dimensions. Since the understanding reward is the key additional component, this ablation shows that image-quality optimization alone does not account for the Stage-3 gain.

The contribution of Stage 3 is also clearer in direct human evaluation. Figure 8 shows visibly improved medical correctness after RL. In a blinded expert study on the same prompts, the Stage-3 model is preferred in 64% of cases, compared with 19% for the Stage-2 model.

Model A Model B A Preferred Tie B Preferred
MedIGen (SFT + RL) MedIGen (SFT only) 64% 17% 19%

We further report the First-Pass Rate, defined as the fraction of prompts for which the model produces a satisfactory image and correctly accepts it without requiring re-generation. It therefore measures both immediate generation quality and the model’s ability to avoid unnecessary refinement.

Model Sci. Acc. Struct. Corr. Sem. Align. Avg. First-Pass Rate
Janus-Pro-7B 0.30 0.22 0.46 0.33 –
MedIGen (SFT) 0.57 0.52 0.68 0.59 64%
MedIGen (RL) 0.61 0.54 0.71 0.62 80%

Observation. RL increases the First-Pass Rate from 64% to 80%, enabling 16% more prompts to succeed after a single generation without additional re-generation cost. This indicates improved alignment between generation and self-evaluation, with refinement focused on harder cases.

We will move these results to the main paper to more clearly demonstrate the necessity and practical value of the dual-level reward design.


W4: Some other methodological details would also benefit from a stronger discussion, such as quality and diversity of the 150K supervised trajectories.

AW4: The 150K samples form a supervised mixture: (1) approximately 138K filtered text-to-image samples and (2) over 12K generate–reflect–refine trajectories.

(1) Filtered text-to-image samples (~138K). These samples are selected from the 1.21M-pair IlluGen-Image corpus through multi-stage filtering for file validity, resolution, source reliability, watermarks, medical relevance, diagrammatic structure, educational value, and overall visual quality.

  • Quality: A fine-tuned Qwen3-VL-8B performs the medical and visual screening. A subsequent manual audit shows an approximately 98% acceptability rate.
  • Diversity: The samples cover five major medical illustration categories:
Category Proportion
Anatomical 37.1%
Educational 23.0%
Disease & Disorder 17.4%
Molecular & Cellular 16.6%
Surgical 4.3%

(2) Generate–reflect–refine trajectories (>12K). The trajectory instructions are constructed from more than 15K MeSH-derived biomedical concepts and expanded into detailed medical illustration requests. The instructions have a mean length of 273 words and a median length of 251 words. Each trajectory contains an initial generation, an image-specific reflection, and a targeted refinement.

  • Quality: We conduct a stratified audit of 400 trajectories, with two medical experts independently evaluating the instruction, reflection, and refinement.
Audit Criterion Acceptability
Medical validity of the instruction 97.3%
Correctness and image grounding of the reflection 94.8%
Specificity and actionability of the correction 95.5%
Consistency between reflection and refinement 93.8%
Overall trajectory acceptability 92.5%

The two experts achieve a Cohen’s κ of 0.87, indicating strong annotation consistency.

  • Diversity: The trajectories span five medical illustration categories:
Category Number of Trajectories Proportion
Anatomical 4,286 34.3%
Educational 2,905 23.3%
Disease & Disorder 2,364 18.9%
Molecular & Cellular 2,072 16.6%
Surgical 853 6.8%
Total 12,480 100.0%

The reflections also cover diverse and complementary error types. Because a trajectory may contain multiple errors, these categories are analyzed using multi-label annotation:

Error Type Number of Trajectories Proportion
Scientific or medical-content errors 7,086 56.8%
Structural or spatial-relation errors 5,614 45.0%
Semantic or instruction-alignment errors 4,332 34.7%
Multiple error types 3,684 29.5%

Together, the 138K text-to-image samples provide broad and high-quality medical visual knowledge, while the 12K+ interleaved trajectories provide diverse process-level supervision for identifying and correcting image-specific medical errors.

We will incorporate these composition statistics, quality-audit results, diversity analyses, and representative trajectory examples into the revised manuscript.

Authors · CommentOpenReview ↗

Rebuttal by Authors (Part 2)

Q2: Can the authors provide a stronger ablation comparing no RL, standard image-level RL and dual-level RL (proposed)? This would clarify whether the proposed reward decomposition is responsible for the gains.

AQ2: We add a controlled image-level RL baseline. All three settings are based on the same Stage-2 SFT checkpoint.

No RL directly evaluates this checkpoint, while the two RL variants continue training with the same data, evaluator, and optimization budget. Image-level RL retains only the generation rewards.

Setting Sci. Acc. Struct. Corr. Sem. Align. Avg.
No RL 0.5743 0.5082 0.6831 0.5885
Image-level RL 0.5833 0.5252 0.6793 0.5959
Dual-level RL 0.6064 0.5368 0.7111 0.6183

Observation. Image-level RL provides limited improvement (+0.0074 Avg.), while dual-level RL achieves larger gains (+0.0224 Avg.) across all dimensions, showing the additional value of aligning self-evaluation with actual generation quality provides additional supervision beyond image-level rewards alone.


Q3: Is there a specific failure pattern over the failure cases for the disease images? Is there evidence that suggests that further reflection iterations would solve?

AQ3: We conducted a manual expert audit of all 56 Disease-category cases.

Phase Outcome Cases
Self-Reflection Correctly identified the error 34/56
Missed detection / no error 22/56
Re-Generation Failed after the first correction 29/34
Still failed after 2+ rounds 19/29

Observation. The dominant failure pattern is not error recognition, but visual correction: self-reflection correctly identifies the issue in 60.7% of cases, yet 85.3% of these still fail after the first re-generation. Importantly, additional iterations are not sufficient by themselves: 65.5% of first-round failures remain incorrect after multiple rounds.

These residual failures mainly involve subtle pathological morphology and abnormal spatial relationships relative to normal anatomy.


Q4: Since GPT-5.1 is involved in generating captions and initial rubric criteria, how sensitive are benchmark results to rubric wording?

AQ4: We agree that expert refinement alone does not establish that benchmark results are insensitive to rubric wording or the model used for benchmark construction. We conduct two controlled experiments on 50 tasks, with 10 tasks from each illustration category.

  • Rubric wording robustness. Gemini-3-Pro paraphrases the final expert-approved rubrics while preserving their medical meaning. Three experts verify that no criteria are added, removed, or altered. The same generated images are then evaluated using the original and paraphrased rubrics.
Generation Model Original Paraphrased Δ
Janus-Pro-7B 0.4468 0.4225 −0.0243
Qwen-Image-2512 0.6374 0.5896 −0.0478
Gemini-3-Pro-Image 0.8962 0.8611 −0.0351
MedIGen 0.7165 0.6849 −0.0316

Observation. The mean score change is 0.0347, while the model ranking remains unchanged (Spearman ρ=1.00), indicating that wording affects absolute scores but not comparative conclusions.

  • Benchmark-generation robustness. Gemini-3-Pro independently regenerates the captions and initial criteria, followed by the same three-expert refinement process. Its rubrics contain more criteria (33.12 vs. 30.46) and longer criteria (35.87 vs. 30.34 words) than the GPT-5.1-assisted version.
Generation Model GPT-5.1-Assisted Gemini-3-Pro-Assisted Δ
Janus-Pro-7B 0.4468 0.3952 −0.0516
Qwen-Image-2512 0.6374 0.5731 −0.0643
Gemini-3-Pro-Image 0.8962 0.8284 −0.0678
MedIGen 0.7165 0.6706 −0.0459

Observation. The larger mean change (0.0574) likely reflects the stricter and more detailed Gemini-3-Pro-assisted rubrics. Nevertheless, the model ranking remains unchanged (Spearman ρ=1.00).

Overall, rubric wording and generation choices affect score calibration but not the main conclusions of IlluGenBench. We will include these analyses in the revised manuscript.


L1: the paper could more explicitly discuss limitations related to benchmark construction, dependence on the MLLM-as-judge framework and potential bias introduced by AI-assisted rubric generation. These should be acknowledged more clearly.

AL1: We agree that these limitations should be stated more explicitly.

We will revise the limitations section to clarify that:

  1. benchmark coverage is constrained by the selected data sources, task taxonomy, and expert pool;
  2. MLLM-based judging may retain model-specific biases and miss subtle medical errors;
  3. AI-assisted rubric drafting may introduce bias in criterion wording and coverage. Thus, IlluGenBench serves as a scalable, human-validated benchmark rather than a substitute for expert evaluation.

All revisions will be added in the next version of the paper.

Reviewer iiC6 · CommentOpenReview ↗

I thank the authors for the detailed rebuttal. Most of my concerns have been properly addressed, so I suggest acceptance of the paper.

Authors · CommentOpenReview ↗

Acknowledgments and Responses to Reviewer Feedback

We sincerely thank the reviewer for the thoughtful reassessment and constructive feedback. We will carefully incorporate these suggestions into the final revision:

  • clarify the scope of our reliability claims;
  • add the controlled no-RL, image-level RL, and dual-level RL ablation;
  • report robustness analyses for rubric wording and AI-assisted benchmark construction, and expand the discussion of MLLM-as-judge bias;
  • expand the limitations discussion to cover benchmark coverage, dependence on MLLM-based judging, AI-assisted rubric bias, and the distinction between scalable evaluation and expert assessment;
  • provide detailed statistics and expert audits on the composition, quality, diversity, and error coverage of the 150K supervised training samples.

We greatly appreciate the reviewer’s time and valuable insights.

Reviewer Xk7fOpenReview ↗
Rating
4/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
2/4
Originality
2/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper studies the reliability of the text-to-image generation model for medical images. The author argues that the medical image generation should have reasonable biomedical semantics, spatial relationships, and structural consistency. For this, they introduce MedIGen, coupling generation with self-reflection and regeneration through “generate–reflect–refine” cycles. and a benchmark IlluGenBench with 296 diverse tasks and 9,015 criteria. They test their trained model on several tasks and achieve the best score.

Strengths and weaknesses

Strengths

  1. The motivation is strong. Medical illustration generation is different from general image generation, since visually plausible images can still be medically wrong.
  2. The paper is comprehensive. It includes a benchmark, domain pretraining, supervised training, and RL-based refinement.
  3. The experiments cover many baselines, including commercial T2I models, open-source T2I models, unified generation models, and reasoning-based models. The reward hacking and cross-evaluator analysis is also useful.

Weaknesses

  1. The novelty is limited. All components are based on existing ideas. In my opinion, this paper is better suited for the benchmark and dataset track than the main track.
  2. The paper lacks stronger test-time baselines. I wonder how well simpler agent-based, rethinking-based, or other test-time methods would perform.
  3. The evaluation relies heavily on MLLM judges. This is a dilemma: the paper questions the reliability of existing T2I models, but trusts MLLMs to judge medical correctness. I'm not sure whether this will still be a problem for the T2I model in 1-2 years.
Questions
  1. Could the authors clarify what they view as the main new technical contribution beyond combining existing components, such as domain pretraining, generate-reflect-refine, GRPO, and MLLM rewards? It would also be helpful to discuss whether simpler approaches, such as prompt optimization, could address part of the problem.

  2. Could the authors compare with simple agent-based or test-time baselines and report their performance? This would help clarify whether the proposed training pipeline is necessary.

  3. What is the authors' view on this problem in the next 1-2 years? Do they expect current T2I models to continue to suffer from similar medical reliability issues as general image generation models improve?

Limitations

Yes

Final justification

The rebuttal addresses several of my concerns regarding novelty and evaluation, and I consider IlluGenBench a valuable contribution. However, the method’s restricted applicability to unified models, together with uncertainty about its effectiveness on stronger future T2I backbones, limits its practical significance. Balancing these strengths and limitations, I recommend 4: Borderline Accept.

Formatting concerns

No major formatting or anonymity issues noticed.

9 comments
Authors · CommentOpenReview ↗

Rebuttal by Authors (Part 1)

We sincerely appreciate your valuable feedback. Below, we address each concern.


W1: The novelty is limited. All components are based on existing ideas. In my opinion, this paper is better suited for the benchmark and dataset track than the main track.

AW1: We appreciate the reviewer’s concern that all components are based on existing ideas. Our novelty claim is not that each component is individually unprecedented, but that MedIGen formulates medical illustration generation as an introspection-driven visual reasoning problem and introduces a training formulation that internalizes medical visual diagnosis and correction into the generation policy.

Medical illustration differs from general T2I generation because visual plausibility and semantic alignment do not guarantee anatomical correctness, structural validity, pathological fidelity, or procedural correctness. As shown in Figures 1 and 2, even strong commercial models can produce polished but medically invalid outputs.

MedIGen addresses this problem through three coupled contributions:

  1. Problem formulation: replacing one-pass synthesis with a unified generate–reflect–refine process in which the model inspects its own output, identifies biomedical errors, and determines whether refinement is required.
  2. Training methodology: combining biomedical visual grounding, reflection–refinement trajectory learning, and dual-level RL so that medical error diagnosis becomes an intermediate learning objective for corrective generation.
  3. Evaluation infrastructure: introducing IlluGenBench with 9,015 expert-refined criteria for scientific accuracy, structural correctness, and semantic alignment. It is designed to measure the medically meaningful capabilities targeted by the proposed training method, rather than serving only as a dataset collection.

The key distinction from simpler approaches is that test-time methods elicit capabilities already present in a generator, whereas MedIGen changes what the generator is trained to identify and correct. We verify this through matched-budget comparisons. All refinement-based baselines use the same Janus-Pro-7B generator, GPT-5.5 as the external multimodal critic, and at most three generation attempts.

Method Setting Sci. Acc. Struct. Corr. Sem. Align. Avg.
Janus-Pro-7B One-pass generation 0.2977 0.2244 0.4628 0.3276
+ Best-of-3 Additional sampling 0.3441 0.2768 0.5042 0.3750
+ Test-time Prompt Refinement Prompt optimization 0.4308 0.3655 0.5714 0.4559
+ MLLM Critique–Refine Agent Agent-based refinement 0.4746 0.4072 0.6085 0.4968
+ Iterative Self-Refinement Rethinking-based refinement 0.4918 0.4237 0.6140 0.5032
MedIGen, MGR=1 Trained policy without re-generation 0.5743 0.5082 0.6831 0.5853
MedIGen, MGR=3 Trained reflect–refine policy 0.6064 0.5368 0.7111 0.6183

The test-time methods consistently improve over one-pass generation, confirming that additional sampling, prompt optimization, and external critique address part of the problem. However, their best result is 0.5032, compared with 0.6183 for MedIGen. More importantly, MedIGen with MGR=1, which disables re-generation, already reaches 0.5853 and exceeds the strongest three-attempt test-time baseline by 0.0821. Increasing MGR from 1 to 3 contributes a further 0.0330 gain.

We also isolate whether the contribution is simply the application of GRPO. All variants start from the same Stage-2 checkpoint and use the same training data, evaluator, and optimization budget.

Setting Sci. Acc. Struct. Corr. Sem. Align. Avg.
No RL 0.5743 0.5082 0.6831 0.5885
Image-level RL 0.5833 0.5152 0.6893 0.5959
Dual-level RL 0.6064 0.5368 0.7111 0.6183
Metric SFT Dual-Level RL Change
First-Pass Success Rate 64% 80% +16 percentage points
Average Generation Rounds 1.58 1.41 −0.17
High-Severity Error Rate 23% 12% −11 percentage points

Image-level RL yields only a +0.0074 average gain, whereas dual-level RL provides a further +0.0224 improvement across all dimensions. It also increases first-pass success, reduces unnecessary generation rounds, and lowers severe medical errors. These results show that the proposed objective learns both when refinement is needed and how the image should be corrected, rather than merely optimizing final-image quality.

IlluGenBench is an important supporting contribution, but the central contribution is a model and training paradigm that makes medical error diagnosis an explicit intermediate objective for learning corrective image generation. We will revise the Introduction and Contributions to make this methodological distinction clearer.

Authors · CommentOpenReview ↗

Rebuttal by Authors (Part 2)

W2 & Q2: The paper lacks stronger test-time baselines. I wonder how well simpler agent-based, rethinking-based, or other test-time methods would perform.

AW2 & Q2: We add stronger baselines that directly correspond to the reviewer’s suggested settings. For a controlled comparison, all refinement-based baselines use GPT-5.5 as the same external multimodal model to inspect the generated image and provide test-time feedback, with a maximum of three generation attempts.

  • Agent-based: an MLLM Critique–Refine Agent [1], where GPT-5.5 identifies errors in the current image and provides explicit corrective instructions for re-generation.
  • Rethinking-based: Iterative Self-Refinement [2], where GPT-5.5 repeatedly reconsiders the current image and previous feedback before proposing the next refinement.
  • Test-time: Test-time Prompt Refinement (TIR) [3], where GPT-5.5 rewrites the generation prompt based on the current image; we also include Best-of-3 to isolate the benefit of additional sampling alone.
Method Category Sci. Acc. Struct. Corr. Sem. Align. Avg.
Janus-Pro-7B One-pass 0.2977 0.2244 0.4628 0.3276
+ Best-of-3 Test-time 0.3441 0.2768 0.5042 0.3750
+ MLLM Critique–Refine Agent [1] Agent-based 0.4746 0.4072 0.6085 0.4968
+ Iterative Self-Refinement [2] Rethinking-based 0.4918 0.4237 0.6140 0.5032
+ TIR [3] Test-time 0.4308 0.3655 0.5714 0.4559
MedIGen Trained reflect–refine 0.6064 0.5368 0.7111 0.6183

The results separate the effects of additional sampling, test-time prompt refinement, external agent feedback, and iterative rethinking. All improve over one-pass generation, confirming that test-time refinement is useful. However, they remain below MedIGen, even with a strong external multimodal model. This suggests that the gain is not explained by additional test-time compute or generic external feedback alone, and supports the benefit of training the reflection–refinement capability into the model.

References

[1] Self-correcting LLM-controlled Diffusion Models.

[2] Idea2Img: Iterative Self-Refinement with GPT-4V(ision) for Automatic Image Design and Generation.

[3] Test-time Prompt Refinement for Text-to-Image Models.

Authors · CommentOpenReview ↗

Rebuttal by Authors (Part 3)

W3: The evaluation relies heavily on MLLM judges. This is a dilemma: the paper questions the reliability of existing T2I models, but trusts MLLMs to judge medical correctness. I'm not sure whether this will still be a problem for the T2I model in 1-2 years.

AW3: We agree that this is a valid dilemma: MLLMs remain imperfect medical evaluators and should not be treated as ground truth. IlluGenBench instead uses them as scalable criterion-level judges grounded by human-approved, task-specific rubrics and reference images, replacing unconstrained holistic judgment with explicit medical verification.

1. Effect of rubric grounding. We evaluate the same expert-annotated outputs under two settings, fixing the generated image, prompt, reference image, judge, and decoding configuration. Without Rubrics, the judge freely identifies medical errors, which two blinded experts map to the canonical criterion labels. With Rubrics, the judge directly verifies each expert-approved criterion. Both settings are compared against the same human labels using Macro-F1.

Judge Without Rubrics With Rubrics Improvement
Qwen3.6-27B 0.538 0.719 +0.181
Gemini-3-Pro 0.667 0.771 +0.104

Rubric grounding substantially improves both judges. It reduces omissions and ambiguity in open-ended assessment, transforming free-form error discovery into explicit criterion-by-criterion verification. The larger improvement for Qwen3.6-27B further indicates that explicit medical criteria can partially compensate for weaker evaluator capability, although Gemini-3-Pro remains stronger in both settings.

Separately, as reported in Appendix E.2, Figure 11, expert refinement of the initially MLLM-generated rubrics improves Macro-F1 from 0.546 to 0.760, further demonstrating the importance of human-grounded criteria.

2. Judge–human agreement. On expert-annotated outputs, rubric-grounded judgments from all three evaluators show substantial agreement with human criterion-level labels:

Image Source GPT-5.1–Human Gemini-3-Pro–Human Qwen3.6-27B–Human
Gemini-3-Pro-Image 0.741 0.782 0.724
MedIGen 0.735 0.760 0.713
Mean 0.738 0.771 0.719

Even the smaller open-source Qwen3.6-27B achieves 0.719 Macro-F1, supporting the scalability of rubric-grounded evaluation across judges with different capabilities.

3. Cross-evaluator consistency. We evaluate all generators using GPT-5.1, Gemini-3-Pro, and Qwen3.6-27B under the same rubrics:

Generator GPT-5.1 Gemini-3-Pro Qwen3.6-27B Rank
Janus-Pro-7B 0.4468 0.3952 0.3564 4
Qwen-Image-2512 0.6374 0.5731 0.6235 3
Gemini-3-Pro-Image 0.8962 0.8284 0.8909 1
MedIGen 0.7165 0.6706 0.6490 2

Although absolute scores differ, all three evaluators produce the same generator ranking, with pairwise Spearman ρ=1.000\rho=1.000.

4. Repeated-run stability. We independently repeat Qwen3.6-27B evaluation three times using identical images, prompts, and rubrics:

Generator Run 1 Run 2 Run 3 Mean ± Std.
Janus-Pro-7B 0.3562 0.3835 0.3294 0.3564 ± 0.0271
Qwen-Image-2512 0.6238 0.6521 0.5947 0.6235 ± 0.0287
Gemini-3-Pro-Image 0.8916 0.9132 0.8678 0.8909 ± 0.0227
MedIGen 0.6489 0.6837 0.6145 0.6490 ± 0.0346

Absolute scores exhibit modest variation, while the generator ranking remains unchanged across runs.

Together, these results do not establish MLLMs as ground truth. Instead, they show that human-approved rubrics constrain different MLLMs—including a smaller open-source model—into scalable criterion-level judges with substantial human agreement and stable comparative conclusions.

Reviewer pxiWOpenReview ↗
Rating
5/6
Confidence
4/5
Quality
4/4
Clarity
4/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The authors propose MedIGen, a text-to-image generation model specifically designed for medical illustrations. The paper argues that visual plausibility does not equate to medical accuracy in this domain. To address this, the authors introduce an interleaved reasoning framework using a "generate, reflect, refine" cycle. The model is trained progressively through domain pre-training, supervised fine-tuning on sub-skills, and reinforcement learning. Furthermore, the paper introduces IlluGenBench, a new evaluation benchmark for medical images with fine-grained rubric criteria.

Strengths and weaknesses

Strengths:

  1. Problem Motivation: The distinction between general visual appeal and strict biomedical validity is highly relevant. The paper identifies a clear gap in existing generative models.
  2. Methodological Design: The multi-stage training pipeline is logical and comprehensive. The iterative refinement process aligns well with the specific nature of medical illustration errors, which are often localized structural inaccuracies rather than global image failures.
  3. Evaluation Resources: IlluGenBench is a substantial contribution to the community. Evaluating scientific accuracy and structural correctness via detailed rubrics is a marked improvement over generic text-image alignment metrics.

Weaknesses:

  1. Overstated Claims: The title and abstract use the word "Reliable", yet the empirical results show an average score of 0.618 and persistent failures in the disease category. The generation quality is improved but not yet fully reliable for deployment.
  2. Evaluation Methodology Constraints: The benchmark heavily relies on closed-source models for automated judging and data construction.
  3. Statistical Rigor: The main benchmark reports single-run results without confidence intervals. Given the inherent variance in generation and automated evaluation, the stability of marginal performance gains is difficult to verify.

Minor: There are several typographical errors and formatting inconsistencies throughout the manuscript.

Questions
  1. A controlled ablation study isolating the causal effect of the reflection text is needed. Comparing the current setup against a baseline that uses multiple generation rounds without the self-reflection step, or one that uses generic feedback, would clarify this contribution.
  2. The representativeness of the long prompts (average 366 words) in IlluGenBench is unclear. Evaluating model performance on a subset of shorter, more realistic user queries would strengthen the benchmark's practical relevance.
Limitations

Yes.

Final justification

I maintain my score of 5 (Accept). The authors effectively addressed my main concerns in the rebuttal by providing solid new experiments, including cross-judge analyses, multi-run results, and reflection ablations. Although questions remain about clinical deployment, evaluator bias, and broader domain generalization, the value of IlluGenBench and the rigorous empirical additions justify acceptance.

Formatting concerns

N/A

3 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We sincerely appreciate your valuable feedback. Below, we address each concern.


W1: Overstated Claims: The title and abstract use the word "Reliable", yet the empirical results show an average score of 0.618 and persistent failures in the disease category. The generation quality is improved but not yet fully reliable for deployment.

AW1: We apologize that some of our wording may have been unclear, and we agree that the current MedIGen should not be interpreted as ready for clinical deployment. Our use of “Reliable” is intended as a comparative claim: MedIGen makes medical illustration generation substantially more reliable than conventional one-pass generation by explicitly identifying and correcting medically invalid content, rather than guaranteeing fully reliable generation.

We will revise the paper to avoid overstating the claim of “Reliable”:

  • Title. We will revise the wording to emphasize progress toward reliability rather than absolute reliability: “Toward Reliable Medical Illustration Generation.”
  • Abstract. We will replace statements that may imply fully reliable generation with more precise comparative wording: “improves the medical reliability of generated illustrations.”

W2: Evaluation Methodology Constraints: The benchmark heavily relies on closed-source models for automated judging and data construction.

AW2: Closed-source models serve two distinct roles. (1) Benchmark construction: they improve the efficiency and scalability of initial drafting, while experts determine the final benchmark. (2) Automated judging: they enable scalable criterion-level evaluation, while their reliability is validated through human agreement, cross-judge robustness, and repeated runs.

(1) Benchmark construction. GPT-5.1 generates only the initial captions and checklist criteria. Three junior experts review and revise every item, followed by validation by two senior experts. Incorrect, ambiguous, redundant, or unverifiable criteria are revised or removed. IlluGenBench is therefore an expert-approved benchmark with AI-assisted drafting, rather than an automatically generated benchmark.

Holding the evaluated images, judge, human annotations, and scoring protocol fixed, expert refinement improves both rubric conciseness and alignment with human judgments:

Rubric Version Avg. Criterion Length (words) Macro-F1 vs. Human
Initial MLLM draft 52.2 0.546
Expert-refined rubric 30.3 0.760

These results confirm that benchmark quality is determined by expert refinement rather than the initial closed-source model output. For reproducibility, we will directly release the finalized rubrics created with the assistance of closed-source models after the paper is accepted.

(2) Automated judging. Closed-source judges support scalable evaluation, but we do not treat them as ground-truth evaluators. To provide an evaluation pathway independent of proprietary APIs, we additionally introduce Qwen3.6-27B as an open-source judge and evaluate all judges through human alignment, cross-judge robustness, and repeated runs.

  • Human alignment. All three judges align well with expert criterion-level annotations. Gemini-3-Pro achieves the highest Macro-F1, while Qwen3.6-27B provides a competitive open-source alternative.
Generation Model GPT-5.1 Gemini-3-Pro Qwen3.6-27B
Gemini-3-Pro-Image 0.741 0.782 0.724
MedIGen 0.735 0.760 0.713
  • Cross-judge robustness. We evaluate the same fixed images and rubrics using the three judges:
Generation Model GPT-5.1 Gemini-3-Pro Qwen3.6-27B
Janus-Pro-7B 0.3367 0.3276 0.3662
Qwen-Image-2512 0.5751 0.6010 0.6238
Gemini-3-Pro-Image 0.8564 0.8730 0.9016
MedIGen 0.6354 0.6183 0.6489

Qwen3.6-27B produces slightly higher absolute scores, but all judge pairs preserve identical model rankings, with a Spearman correlation of ρ = 1.000. Thus, the comparative conclusions are not determined by a particular proprietary judge.

  • Repeated-run stability. We repeat Qwen3.6-27B judging three times using the same images and rubrics:
Model Run 1 Run 2 Run 3 Mean ± Std.
Janus-Pro-7B 0.3562 0.3835 0.3294 0.3564 ± 0.0271
Qwen-Image-2512 0.6238 0.6521 0.5947 0.6235 ± 0.0287
Gemini-3-Pro-Image 0.8916 0.9132 0.8678 0.8909 ± 0.0227
MedIGen 0.6489 0.6837 0.6145 0.6490 ± 0.0346

Although Qwen3.6-27B shows greater run-to-run variation, the model rankings and comparative conclusions remain unchanged. In our setup, it runs at full precision on a single GPU with 40 GB of VRAM, enabling automated evaluation without proprietary APIs.


W3: Statistical Rigor: The main benchmark reports single-run results without confidence intervals. Given the inherent variance in generation and automated evaluation, the stability of marginal performance gains is difficult to verify.

AW3: We agree that single-run results may not adequately characterize the variance introduced by stochastic image generation and automated evaluation. We therefore repeated the complete generation-and-evaluation pipeline 3 times for MedIGen, Janus-Pro-7B, Qwen-Image-2512, and Gemini-3-Pro-Image. Each run covers all 296 IlluGenBench tasks under identical settings. We report the benchmark scores as mean ± sample standard deviation.

Model Run 1 Run 2 Run 3 Mean ± Std.
Janus-Pro-7B 0.3276 0.3428 0.3167 0.3290 ± 0.0131
Qwen-Image-2512 0.6010 0.6112 0.5906 0.6009 ± 0.0103
Gemini-3-Pro-Image 0.8730 0.8826 0.8654 0.8737 ± 0.0086
MedIGen 0.6183 0.6359 0.6011 0.6184 ± 0.0174

Observation. The repeated runs show modest variation, while the overall model ranking and conclusions remain consistent. This indicates that the observed performance differences are stable and not driven by a single run.

In the revised manuscript, we will include these results and extend the stability analysis to additional models and evaluation dimensions.


W4: Minor: There are several typographical errors and formatting inconsistencies throughout the manuscript.

AW4: Thank you for pointing this out. We will carefully proofread the manuscript and correct all typographical errors and formatting inconsistencies.

  • “Evaluation Results of MedGen” → “Evaluation Results of MedIGen” in Sec. 5.2.
  • “IlluBenmark Statistics” → “IlluGenBench Statistics” in Appendix D.1.
  • “external evaluate” → “external evaluator” in Sec. 3.2.3.
  • “0.0.7504” → “0.7504” in Table 10.

These corrections do not affect our methodology, results, or conclusions.


Q1: A controlled ablation study isolating the causal effect of the reflection text is needed. Comparing the current setup against a baseline that uses multiple generation rounds without the self-reflection step, or one that uses generic feedback, would clarify this contribution.

AQ1: We agree that the effect of reflection text should be separated from the benefit of repeated generation. We compare three variants using the same checkpoint, three-round generation budget, random seeds, and inference settings; Only the feedback differs:

  • No Reflection: three generation rounds without feedback.
  • Generic Feedback: “Please improve the image and better follow the prompt.”
  • Specific Medical Reflection (Ours): image-specific medical, structural, and semantic feedback.
Method Sci. Acc. Struct. Corr. Sem. Align. Avg.
No Reflection 0.5795 0.5126 0.6878 0.5899
Generic Feedback 0.5581 0.4944 0.6668 0.5724
Specific Medical Reflection (Ours) 0.6064 0.5368 0.7111 0.6183

Observation. Specific medical reflection performs best across all dimensions. This demonstrates that the improvement primarily comes from targeted medical reflection rather than additional generation rounds alone.

We will include this controlled ablation in the revised manuscript.


Q2: The representativeness of the long prompts (average 366 words) in IlluGenBench is unclear. Evaluating model performance on a subset of shorter, more realistic user queries would strengthen the benchmark's practical relevance.

AQ2: We agree that the original IlluGenBench prompts are more detailed than typical user queries. They are designed to specify key medical and structural requirements for controlled evaluation.

To assess practical relevance, we sample 100 tasks from the five illustration tasks (20 per category) and rewrite them into concise user-style queries while preserving the core medical intent, reducing the average prompt length from 366 to 38 words.

Model Full Prompts Short Queries Drop
Janus-Pro-7B 0.3082 0.2578 −0.0504
Qwen-Image-2512 0.4627 0.4186 −0.0441
Gemini-3-Pro-Image 0.6785 0.6599 −0.0186
MedIGen 0.5764 0.5552 −0.0212

Observation. The results provide three insights. First, shortening prompts causes only moderate degradation while preserving the model ranking (Spearman ρ = 1.00), showing that IlluGenBench conclusions are not driven by prompt verbosity. Second, concise queries remove explicit anatomical and structural cues, placing more emphasis on internalized biomedical knowledge. MedIGen remains relatively robust (−0.0212), suggesting that its gains extend beyond detailed specifications to more realistic user-style queries.

Reviewer pxiW · CommentOpenReview ↗

Most of my concerns have been adequately addressed in the rebuttal. Considering the feedback from all reviewers, I maintain my rating as accept.

Authors · CommentOpenReview ↗

Acknowledgments and Responses to Reviewer Feedback

We sincerely thank the reviewer for the constructive feedback and detailed suggestions. We will carefully incorporate them into the final revision:

  • revise the title, abstract, and main text to clarify that MedIGen improves reliability comparatively rather than guaranteeing deployment-ready generation;
  • strengthen the evaluation methodology discussion, and add evaluation with the open-source Qwen3.6-27B judge;
  • report three-run mean and standard deviation for the main benchmark results;
  • correct all typographical errors and formatting inconsistencies throughout the manuscript.

We greatly appreciate the reviewer’s time and valuable insights, which have helped us improve the rigor, reproducibility, and clarity of the paper.

Comments on the paper

1 comment
Area Chair MEfg · CommentOpenReview ↗

The authors have now posted their rebuttals. For those who haven't yet joined the discussion, please review their responses carefully and actively engage in the discussion phase, particularly for borderline papers where your input is crucial for reaching a consensus.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Missing a submission?

Loading the discussion…