Coarse-to-Fine 3D MRI Reconstruction via Resolution-Agnostic Neural Operators
Jiayun Wang, Ram Daftari, Weijie Gan, Valentin Duruisseaux, Ruibo Wang, Armeet Singh Jatyani, Boris Bonev, Anima Anandkumar
NeurIPS 2026
TL;DR. KIR-NO, a memory-efficient neural network framework that trains on low-resolution 3D MRIs can successfully reconstruct high-resolution scans without needing to be fine-tuned.
Abstract. Deep-learning-based 3D MRI reconstruction is limited in practice by the GPU memory and compute cost of full-volume training; 3D acquisitions are thus most often reconstructed by 2D models applied slice-by-slice and then stacked, which ignores through-plane (stacking-axis) structure. We reconstruct in full 3D and ask whether a model can be trained at low resolution (fast and memory-feasible) yet deployed at higher resolution. This coarse-to-fine strategy needs reliable cross-resolution performance, but standard networks are resolution-specific and degrade substantially when evaluated outside the training setting. We therefore use resolution-agnostic neural operators (NOs) and propose KIR-NO (k-space-to-Image Reconstruction Neural Operator), a discretization-agnostic framework for accelerated 3D MRI reconstruction. KIR-NO is trained with full backpropagation on low-resolution volumes and applied zero-shot to higher-resolution volumes at inference. Its core building block is a 3D neural operator based on discrete-continuous convolutions: convolutional filters are parameterized in a continuous basis and sampled at arbitrary voxel resolutions while preserving the local inductive bias of convolution. KIR-NO integrates these learned operators with physics-based consistency: a k-space neural-operator head first refines the undersampled Fourier measurements, and image-space neural-operator cascades then refine the reconstruction through interleaved data-consistency updates. Across 3D knee and brain MRI benchmarks, KIR-NO improves over classical and CNN baselines: it improves over a state-of-the-art 3D CNN by 2.2 dB PSNR at half resolution under 4× acceleration on SKM-TEA, with gains persisting at 8× and 16×. Together, these results show that resolution-agnostic operators make coarse-to-fine 3D MRI reconstruction — cheap low-resolution training with high-resolution deployment — practical across anatomies. Our code is available at: https://github.com/neuraloperator/KIR-NO.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:46 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
Thank you for submitting this paper. The reviewers generally agree that addressing memory-efficient 3D MRI reconstruction through low-resolution training and high-resolution inference is an important and practically relevant problem. The combination of neural operators with an unrolled MRI reconstruction framework was viewed as a technically reasonable approach, and the reported improvements over the E2E-VarNet baselines suggest promising potential. At the same time, the reviewers raised several significant concerns regarding the experimental methodology and the extent to which the current empirical evidence supports the paper’s central claims. The comments below summarize the major discussion points rather than providing an exhaustive list. Addressing these concerns would substantially strengthen the work.
- The experimental protocol requires stronger validation under realistic MRI acquisition settings. Multiple reviewers considered this to be the primary weakness of the paper. In particular, the proposed cross-resolution setting is based on downsampling and interpolation of MRI data, which may alter the underlying k-space frequency structure and therefore may not faithfully represent genuine high-resolution acquisition. As a result, the reviewers felt that the current experiments do not sufficiently establish that the reported gains would translate to realistic clinical settings.
- The experimental comparisons and positioning should be strengthened. Several reviewers noted that the empirical evaluation omits a number of recent MRI reconstruction approaches, including transformer-, state-space-, diffusion-, and neural-operator-based methods. In particular, reviewers questioned how the proposed method differs from and improves upon recent neural-operator MRI reconstruction frameworks that also study robustness across resolutions or undersampling patterns. A clearer positioning with more comprehensive comparisons would better establish the novelty and practical significance of the work.
- Several important aspects of the experimental protocol require clarification. The reviewers requested clarification regarding the training strategy across acceleration rates, specifically whether a single model generalizes across sampling rates or separate models are trained for each setting. Additional details regarding the evaluation protocol, particularly the construction of the high-resolution experiments and the use of synthetic versus real raw k-space data, would improve reproducibility and interpretation of the reported results.
- Additional analyses would strengthen the empirical evidence. The reviewers requested broader evaluations, including computational efficiency (e.g., parameter count, memory consumption, training and inference cost), statistical stability across multiple runs, clinically relevant evaluation metrics beyond PSNR/SSIM/NMSE, and more comprehensive ablations of the proposed architectural components. These analyses would help better understand both the practical advantages and the limitations of the proposed framework.
Overall, the reviewers recognize the practical importance of improving memory-efficient 3D MRI reconstruction and view the proposed framework as an interesting application of neural operators to this setting. However, the current experimental evidence does not yet convincingly support several of the paper’s central claims, particularly regarding zero-shot high-resolution generalization and practical applicability under realistic acquisition scenarios. Addressing these concerns would likely require more substantial experimental validation, broader comparisons with recent methods, and a clearer characterization of the method’s capabilities than can reasonably be expected during the rebuttal period. The reviewers’ comments therefore provide constructive guidance for strengthening a future version of the work.
Final justification
Taking into account the rebuttal and subsequent discussion, I believe the authors have addressed most of the major empirical and methodological concerns raised in the initial reviews. In particular, they clarified the cross-resolution acquisition protocol and acceleration-rate setting, added comparisons with recent transformer-, neural-operator-, and diffusion-based baselines, provided robustness and clinically relevant evaluations, expanded computational and memory analyses, and demonstrated full-resolution inference within a 24 GB GPU budget. These additions substantially strengthen the empirical support for the paper’s central claims.
The main remaining concern is the degree of method-specific novelty, as noted by Reviewer KU44: coarse-to-fine resolution transfer is partly an inherent benefit of neural operators. Nevertheless, the native 3D operator construction, volumetric reconstruction framework, and practical treatment of the memory bottleneck constitute meaningful contributions beyond prior 2D/slice-wise approaches. Given that the major experimental concerns underlying the initial negative assessments were substantially resolved during discussion, I view the final version more favorably than reflected in my initial meta-review and recommend acceptance.
Read meta-review
Meta-review
Thank you for submitting this paper. The reviewers generally agree that addressing memory-efficient 3D MRI reconstruction through low-resolution training and high-resolution inference is an important and practically relevant problem. The combination of neural operators with an unrolled MRI reconstruction framework was viewed as a technically reasonable approach, and the reported improvements over the E2E-VarNet baselines suggest promising potential. At the same time, the reviewers raised several significant concerns regarding the experimental methodology and the extent to which the current empirical evidence supports the paper’s central claims. The comments below summarize the major discussion points rather than providing an exhaustive list. Addressing these concerns would substantially strengthen the work.
- The experimental protocol requires stronger validation under realistic MRI acquisition settings. Multiple reviewers considered this to be the primary weakness of the paper. In particular, the proposed cross-resolution setting is based on downsampling and interpolation of MRI data, which may alter the underlying k-space frequency structure and therefore may not faithfully represent genuine high-resolution acquisition. As a result, the reviewers felt that the current experiments do not sufficiently establish that the reported gains would translate to realistic clinical settings.
- The experimental comparisons and positioning should be strengthened. Several reviewers noted that the empirical evaluation omits a number of recent MRI reconstruction approaches, including transformer-, state-space-, diffusion-, and neural-operator-based methods. In particular, reviewers questioned how the proposed method differs from and improves upon recent neural-operator MRI reconstruction frameworks that also study robustness across resolutions or undersampling patterns. A clearer positioning with more comprehensive comparisons would better establish the novelty and practical significance of the work.
- Several important aspects of the experimental protocol require clarification. The reviewers requested clarification regarding the training strategy across acceleration rates, specifically whether a single model generalizes across sampling rates or separate models are trained for each setting. Additional details regarding the evaluation protocol, particularly the construction of the high-resolution experiments and the use of synthetic versus real raw k-space data, would improve reproducibility and interpretation of the reported results.
- Additional analyses would strengthen the empirical evidence. The reviewers requested broader evaluations, including computational efficiency (e.g., parameter count, memory consumption, training and inference cost), statistical stability across multiple runs, clinically relevant evaluation metrics beyond PSNR/SSIM/NMSE, and more comprehensive ablations of the proposed architectural components. These analyses would help better understand both the practical advantages and the limitations of the proposed framework.
Overall, the reviewers recognize the practical importance of improving memory-efficient 3D MRI reconstruction and view the proposed framework as an interesting application of neural operators to this setting. However, the current experimental evidence does not yet convincingly support several of the paper’s central claims, particularly regarding zero-shot high-resolution generalization and practical applicability under realistic acquisition scenarios. Addressing these concerns would likely require more substantial experimental validation, broader comparisons with recent methods, and a clearer characterization of the method’s capabilities than can reasonably be expected during the rebuttal period. The reviewers’ comments therefore provide constructive guidance for strengthening a future version of the work.
Final justification
Taking into account the rebuttal and subsequent discussion, I believe the authors have addressed most of the major empirical and methodological concerns raised in the initial reviews. In particular, they clarified the cross-resolution acquisition protocol and acceleration-rate setting, added comparisons with recent transformer-, neural-operator-, and diffusion-based baselines, provided robustness and clinically relevant evaluations, expanded computational and memory analyses, and demonstrated full-resolution inference within a 24 GB GPU budget. These additions substantially strengthen the empirical support for the paper’s central claims.
The main remaining concern is the degree of method-specific novelty, as noted by Reviewer KU44: coarse-to-fine resolution transfer is partly an inherent benefit of neural operators. Nevertheless, the native 3D operator construction, volumetric reconstruction framework, and practical treatment of the memory bottleneck constitute meaningful contributions beyond prior 2D/slice-wise approaches. Given that the major experimental concerns underlying the initial negative assessments were substantially resolved during discussion, I view the final version more favorably than reflected in my initial meta-review and recommend acceptance.
3 comments
MR8. Statistical stability and error bars (→ ttAK W3). We added 95% confidence intervals, which are disjoint for all three metrics across (n = 33) validation volumes. The gains are also consistent across 3 resolutions, 2 anatomies, and 3 acceleration rates.
MR9. Full computational accounting (→ ttAK W4; 92fo W4). We rectified the inference comparison to 3.54 versus 2.61 seconds end-to-end. Under a compute-matched comparison, a quarter-trained KIR-NO outperforms the half-trained CNN by +2.6 dB while using 57% less training memory, a capability unavailable to the fixed-grid CNN.
MR10. Clinically relevant ROI metrics (→ ttAK Q3). On the BraTS tumour ROI (n = 251), KIR-NO achieves an SSIM of 0.853 inside the lesion, compared with 0.290 for the CNN. This structural margin is substantially larger than the whole-image difference and is not captured by whole-image averages.
MR11. Component ablations are already included (→ 92fo W3). Appendix F includes ablations of the basis function, where piecewise-linear substantially outperforms Morlet, kernel size and radius cutoff, and cascade count.
Overall. The acquisition clarification (MR1), the added operator, transformer, and diffusion comparisons in which KIR-NO leads consistently (MR3, MR4), the new robustness, statistical, computational, and clinical evidence (MR2, MR8–MR10), and the previously overlooked ablations (MR11) address the concerns underlying the two rejection ratings without changing the method or its claims. We believe that these comprehensively address all the reviewers’ concerns and also strengthen the empirical support for our conclusions. We respectfully hope that they will be taken into account positively in the reassessment of the submission.
Summarizing Our Responses
Dear Area Chair,
We appreciate the meta-review's concern that fully addressing these points would require more validation than the rebuttal period allows, and we would like to note that the corresponding experiments were completed and submitted within the discussion period. Building on the initial set of experiments we ran for each reviewer, which the meta-review reflects, we document below the further clarifications and experiments we have since provided in response to the reviewers' subsequent questions.
- Validation under realistic acquisition settings. Data is only interpolated in the image domain. KIR-NO trained on quarter resolution performs well even on natively collected full-resolution SKM-TEA data, which shows satisfactory zero-shot generalization. We further report noise and cross-scanner shift experiments and volumetric tumor-ROI metrics
- Memory cost and deployability. Reviewer 92fo asked whether full-resolution inference was practical. We introduced two exact, output-preserving changes, overlapping patch execution and sequential per-coil data consistency, reducing peak memory for (512×512×320) inference to 22.33 GB with PSNR unchanged at 33.6 dB. This enables full-volume inference on a single 24 GB GPU. In a like-for-like 3D comparison, KIR-NO also requires substantially less memory than Diffusion-3D Physics, 22.33 GB versus 56.5 GB. Diffusion-CSGM uses less memory at 14.5 GB only by reconstructing slices independently, thereby discarding through-plane information and reintroducing precisely the volumetric inconsistency that KIR-NO is designed to address.
- Resolution robustness and corrected quarter-resolution results. We retrained the quarter-resolution KIR-NO configuration after identifying a split-specific scaling mismatch and verified that all other reported results were unaffected. The corrected model now outperforms every baseline at quarter resolution and under zero-shot transfer to both half and full resolution. At half-resolution evaluation, quarter-resolution KIR-NO exceeds a 3D E2E-VarNet trained directly at half resolution by 2.6 dB while using less time and memory per training step. Moreover, reducing KIR-NO's own training resolution by half incurs only a 0.68 dB penalty. Together, these results provide direct and compelling evidence for the resolution robustness central to the paper. The Diffusion 3D Baseline metrics are matched by the updated KIR-NO (10 Cascades) result with a lower inference time for our model.
- Clarification of 2D baseline evaluation. We clarified that all 2D baseline metrics are computed volume-wise after stacking the reconstructed slices, using exactly the same evaluation procedure as for the 3D methods. The comparison is thus fully consistent and directly comparable across 2D and 3D approaches.
- Baseline fairness and computational trade-offs. We defined the matched-budget setting precisely and also evaluated both diffusion baselines using their full original sampling trajectories. We report these results transparently, including cases where a baseline achieves higher PSNR. In particular, full-trajectory Diffusion-CSGM exceeds KIR-NO in PSNR but requires 316 s per full-resolution volume, compared with 2.76 s for a single KIR-NO cascade. Our contribution is not maximum PSNR under effectively unbounded inference compute, but resolution-robust, fully volumetric reconstruction that trains at quarter resolution, transfers zero-shot to full resolution, and operates in a single forward pass. The revised timing tables now make this accuracy-efficiency trade-off explicit.
We are grateful to all reviewers for a constructive discussion that materially strengthened the paper. We believe the rebuttal and additional analyses addressed the substantive concerns raised during review.
- Rating
- 4/6
- Confidence
- 2/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
KIR-NO is a method that attempts to lower computational burden at training time for MRI super-resolution by adopting neural operators as well as custom kernel bases. Experiments across two public datasets prove some performance gains, however, I still have some questions that wishes to be addressed in the discussion period.
Strengths and weaknesses
Strengths:
- The method design, such as choosing a unrolling model with neural operators, as well as the adaptation of kernel bases is relevant and useful for 3D MRI reconstruction
- The general idea is easy to understand, and using neural operators for MRI super-resolution is a natural way to approach this task.
Weaknesses:
- The main problem of this paper is the experiments design. While the paper only compares with CNN-based baselines, a majority of concurrent works also approaches MRI superresolution with diffusion networks. This paper only briefly touched it in the appendix with constraints on their inference steps, which seems unfair.
- The paper misses a relevant neural operator-based MRI reconstruction method (A Unified Model for Compressed Sensing MRI Across Undersampling Patterns, CVPR'25), which brings questions to whether their SOTA performance gains persists with the most recent researches.
- The paper does not ablate on the key components (choice of kernel bases, etc.), I also dont understand why the authors trains a model on half-res but evaluate on quad-res, which does not match the super-resolution task this paper is obviously targeted on.
- The training/inference VRAM cost is still alarmingly high, which significantly limits its applicability. And judging from its degraded performance from quad-res training, it is very hard to say that this method will deliver enough academic impact.
Questions
See weaknesses
Limitations
The baseline choice is lacking, and while the authors acknowledges that training/inference VRAM cost can be prohibitively intensive, from my point of view, this limitation is too much for this work to be accepted.
Final justification
The authors addressed my concerns, and thus I have raised my score, these contributions, combined, should make the paper stronger and be accepted; however, considering the amount of experiments to be added at revision, I am unable to fully accept this paper
Formatting concerns
The experiments section referenced Fig.1 that appears at the very beginning of the paper, this slightly breaks the continuity of my reading and is not helpful for general readers
9 comments
Response to Reviewer 92fo (1/2)
We thank the reviewer for their review, which we believe identifies a genuine gap in how we presented the comparisons, and we address each point below.
W1 — Comparison limited to CNN baselines We agree that the baseline coverage should extend beyond CNNs, and added three non-CNN baselines below. Each model has been trained at quarter resolution SKM-TEA data and is evaluated across SKM-TEA across resolutions.
| Evaluated at | LMO (CVPR'25) | ReconFormer | 2D-NO (CVPR’25) | KIR-NO (ours) |
|---|---|---|---|---|
| Quarter 128 × 128 × 80 (in-domain) | 28.89 | 30.67 | 27.13 | 32.32 |
| Half 256 × 256 × 160 (zero-shot) | 26.95 | 32.74 | 20.72 | 34.06 |
| Full 512 × 512 × 320 (zero-shot) | 26.48 | 33.08 | 20.57 | 33.66 |
Regarding diffusion baselines: the Appendix-E comparison is already matched-budget, not a single constrained setting. We evaluate both a single-step regime (one forward pass / one sampling step) and an 11-step regime (equal step count for both methods); KIR-NO leads in both, by +2.5 dB over Diffusion-3D-Physics (Krainovic'24) and +8.0 dB over Diffusion-CSGM (Jalal'21) at a single step on half resolution. Notably, the diffusion models were trained on MRI slices spanning all resolutions, which gives them a substantial advantage over KIR-NO. Nevertheless, KIR-NO still achieves the strongest performance.
We additionally report the diffusion baselines' peak inference memory and latency:
| Method | QR 60 × 60 × 39 | HR 120 × 120 × 78 | FR 240 × 240 × 155 |
|---|---|---|---|
| VarNet3D CNN (trained on QR) | 0.005 s / 0.12 GiB | 0.013 s / 0.80 GiB | 0.094 s / 6.32 GiB |
| VarNet3D CNN (trained on HR) | 0.005 s / 0.16 GiB | 0.014 s / 0.90 GiB | 0.095 s / 6.35 GiB |
| KIR-NO | 0.091 s / 1.28 GiB | 0.390 s / 2.18 GiB | 2.76 s / 8.88 GiB |
| Diffusion 3D (single step) | 0.19 s / 1.32 GiB | 0.77 s / 3.24 GiB | 5.46 s / 12.99 GiB |
| Diffusion 3D (multi step) | 1.15 s / 1.58 GiB | 2.31 s / 4.24 GiB | 12.37 s / 18.78 GiB |
| Diffusion 2D (single step) (batched) | 0.13 s / 0.93 GiB | 0.54 s / 1.61 GiB | 3.63 s / 4.07 GiB |
| Diffusion 2D (multi step) (batched) | 0.79 s / 0.93 GiB | 2.40 s / 1.65 GiB | 13.06 s / 4.23 GiB |
W2 — Missing comparison with "A Unified Model for CS-MRI Across Undersampling Patterns" (2D-NO)
We thank the reviewer for mentioning this work, currently cited and discussed in our manuscript. The referenced method operates in 2D and reconstructs volumes slice by slice, whereas KIR-NO addresses the native 3D reconstruction problem through memory-efficient volumetric processing. This distinction allows KIR-NO to leverage through-plane structure that is unavailable to slice-wise methods. We showed the comparison with the 2D-NO model earlier, and now extend and clarify this positioning in the related-work section.
Response to Reviewer 92fo (2/2)
W3 — Ablations, and why training at half and evaluate at quarter
We thank the reviewer and take this opportunity to clarify two points:
(a) Kernel-basis ablation is presented in Appendix F (piecewise-linear basis ≫ Morlet). We moved it to the main text.
(b) Half → quarter row is included only for completeness of reporting, as a downward-generalisation check and show the proposed KIR-NO works across resolutions, instead of claiming train on high resolution and test on low resolution is a practical clinical use. The super-resolution setting we actually target is train-low → evaluate-high (half → full), and we now label the two directions clearly so the purpose of each row is clear.
W4 — VRAM cost and the quarter-trained setting
We appreciate this point and would like to make three observations.
(1) High VRAM is precisely the bottleneck in 3D MRI reconstruction that this work exists to alleviate.
(2) Training memory scales with the training resolution, not the deployment resolution. Because KIR-NO learns in function space, it can reconstruct at after training at only . This uses 57% less memory than half-resolution training (19.8 vs. 45.8 GB) and has a lower per-step cost than half-resolution CNN training.
(3) The quarter-trained model retains its accuracy at the target resolution:
| Trained at → | Quarter 128×128×80 | Half 256×256×160 |
|---|---|---|
| 3D E2E-VarNet (CNN) | 31.11 | 31.44 |
| KIR-NO (ours) | 34.06 | 34.74 |
This shows that reducing the training resolution by half decreases performance by only 0.68 dB for KIR-NO. Moreover, at the same target resolution, the quarter-trained KIR-NO outperforms the half-trained CNN by 2.6 dB.
Although the CNN can also be evaluated off-grid, its accuracy is consistently lower at every resolution, achieving 31.11 dB at half resolution compared with 34.06 dB for KIR-NO. Finally, within our available memory budget, the CNN could not be trained on the grid, whereas KIR-NO reaches this resolution zero-shot.
Formatting — forward reference to Fig. 1
Thank you for catching this formatting issue. We added a local reference and relocated the content so that the figure is introduced where it is first discussed.
response to authors
I appreciate the authors' detailed rebuttal, I have three more questions after reading it:
- Judging from Figure 5, training KIR-NO on half-res costs 44GB (which is still substantial), and if I use this model to evaluate on full-res at inference, it would be more than 100GB? Actually, if that is the case, how did the authors report the numbers in Tables 1 and 2? Also, since KIR-NO does not consistently lead in quad-res-to-full-res superresolution, other comparisons could train on even smaller resolutions and still achieve desirable results (comparing Table 1 with 4)
- how did the authors evaluate 2D-NO to input 3D volumes for these comparisons, and are the PSNR values computed slice-wise?
- the authors claims that the Appendix-E comparison is already matched-budget, i would like to know what is this budget (compute or time or else) and how many steps did the original diffusion models in [33,34] use. Since without specifically tuning the trajectory of diffusion sampling, for a diffusion model trained on thousands of steps, one-step and 11-step sampling would almost certainly land in undesirable results.
- Rating
- 5/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper presents KIR-NO, which is a coarse-to-fine neural operator framework for 3D MRI reconstruction. The method avoids full-resolution 3D training by performing backpropagation at lower resolution and applying the learned operator to higher-resolution inference. It combines a k-space neural operator head with image-space neural operator cascades and data-consistency updates to preserve the MRI forward model. The experiments on SKM-TEA and BraTS compare KIR-NO with classical reconstruction methods, CNN-based models, 3D U-Net, 3D E2E-VarNet, and diffusion-based baselines. The main result is that KIR-NO improves cross-resolution transfer and performs competitively across different acceleration rates.
Strengths and weaknesses
Strengths
- The paper focuses on an important practical bottleneck in 3D MRI reconstruction, which is the memory and compute cost of full-volume training.
- The coarse-to-fine formulation is interesting. The low-resolution training with high-resolution inference could make 3D reconstruction models easier to train in practice.
- The method is well matched to the MRI inverse problem by combining k-space processing and image-space cascades.
- The evaluation shows improvements over 3D E2E-VarNet in the low-resolution training and full-resolution transfer settings.
Weaknesses
- The zero-shot full-resolution claim needs a stronger qualification, since the current setting appears to rely on interpolated k-space grids rather than raw high-resolution clinical acquisition.
- The evaluation does not fully test realistic shifts, such as coil sensitivity changes, noise shifts, motion artifacts, scanner protocol differences, or genuinely acquired high-frequency information.
- The main results appear to be based on a single run without error bars or confidence intervals, making it difficult to assess the stability of the reported gains.
- The computational analysis is incomplete; the paper should report parameter count, training memory, inference memory, wall-clock training time, and per-volume inference latency.
- Some ablation results need further explanation, especially cases where PSNR and SSIM disagree, which may indicate a trade-off between structural preservation and intensity or high-frequency fidelity.
Questions
Need further clarification on distinguishing interpolation-based cross-resolution transfer from real high-resolution clinical acquisition.
Need clarification on whether BraTS uses synthetic k-space or real brain raw k-space for validation.
Can authors include ROI metrics, tumor fidelity, structure-preservation analysis, and measurement results beyond PSNR, SSIM, and NMSE?
Limitations
yes
Formatting concerns
No
4 comments
Response to Reviewer ttAK (1/2)
We thank the reviewer for the thorough and constructive review. We address each point below.
W1 & Q1 — Qualifying the zero-shot full-resolution claim
We agree this needs a precise statement. On SKM-TEA the full-resolution target is 512×512×320, and the in-plane 512×512 grid is natively acquired. Our model is trained at half resolution (256×256×160) and evaluated at full resolution zero-shot, with fixed weights. Going from 256 to 512 in-plane requires the operator to recover genuinely measured high-frequency content on a grid it never saw during training, rather than content introduced by an upsampling step.
We also clarify that no k-space data is ever interpolated directly. Lower-resolution volumes are resized in image space and the k-space data is then obtained by FFT of that resized image. The k-space data at each resolution is thus the exact transform of a clean image on that grid. We rectify and clarify both the claim and this pipeline in the revision.
W2 — Robustness under realistic shifts
We appreciate the insightful suggestion, and conducted two additional experiments, now included in the manuscript, to explore robustness.
(a) Measurement noise. We inject Additive White Gaussian Noise in the sampled k-space positions at a controlled Signal to Noise ratio. The KIR-NO model as well as 3D E2E Varnet were trained on half-resolution SKM-Tea data and lightly fine-tuned on noisy data for the final 8 epochs. They are both evaluated on noisy half resolution SKM-Tea data on PSNR. KIR-NO leads the CNN baseline at every noise level.
| Measurement SNR (dB) | No noise | 20 | 14 | 8 |
|---|---|---|---|---|
| KIR-NO (noise-aware) | 34.74 | 34.54 | 34.00 | 32.24 |
| 3D E2E-VarNet CNN (noise-aware) | 31.44 | 31.65 | 31.37 | 30.34 |
| Δ | +3.3 | +2.9 | +2.6 | +1.9 |
(b) Cross-scanner transfer (SKM-TEA → fastMRI knee).
i) We test on a different acquisition: models trained on SKM-TEA at quarter resolution and applied to fastMRI knee, which differs in scanner, coil array, protocol and SNR. Both models were trained on the quarter resolution SKM-TEA dataset. In the few shot case, both models were fine-tuned for 15 epochs on 2 FastMRI Knee volumes. The results below are based on evaluation on unseen 33 FastMRI whole Knee Volumes.
| Evaluation on fastMRI knee | PSNR/SSIM (zero-shot) | PSNR/SSIM (few-shot) |
|---|---|---|
| 3D E2E-VarNet (CNN) | 20.89 / 0.485 | 23.15 / 0.573 |
| KIR-NO (ours) | 24.04 / 0.617 | 27.05 / 0.730 |
| Δ | +3.15 / +0.132 | +3.90 / +0.157 |
KIR-NO adapts well (and better than the VarNet) from an already high zero-shot number, reaching a usable reconstruction on a new scanner from very little target data. We note as well that the gap between the VarNet and the KIR-NO increases with light fine-tuning.
ii) We test on resolution changes: both models are trained at quarter resolution (128×128×80) and then evaluated at quarter, half and full resolution without any retraining on PSNR/SSIM. KIR-NO consistently outperforms the CNN baseline at all resolutions.
| SKM-TEA (trained on quarter) | Quarter (in-domain) | Half (zero-shot) | Full (zero-shot) |
|---|---|---|---|
| 3D E2E-VarNet (CNN) | 27.86 / 0.749 | 31.11 / 0.826 | 33.22 / 0.850 |
| KIR-NO (ours) | 32.32 / 0.878 | 34.06 / 0.980 | 33.66 / 0.996 |
| Δ | +4.46 / +0.129 | +2.95 / +0.154 | +0.44 / +0.146 |
W3 — Error bars on multiple runs
We thank the reviewer for this suggestion. We now report variability and confidence intervals across all (n=33) validation volumes from SKM-TEA under the half-resolution, (4\times) setting, with both training and evaluation performed at half resolution. Results are presented as the mean (\pm) standard deviation across volumes, followed in brackets by the two-sided 95% confidence interval for the mean in (t₃₂)
| Metric | KIR-NO (ours) | 3D E2E-VarNet (CNN) |
|---|---|---|
| PSNR (dB) ↑ | 34.74 ± 1.60 [34.17, 35.31] | 31.44 ± 1.67 [30.85, 32.03] |
| SSIM ↑ | 0.888 ± 0.023 [0.880, 0.896] | 0.824 ± 0.038 [0.810, 0.838] |
| NMSE ↓ | 0.023 ± 0.007 [0.0205, 0.0255] | 0.043 ± 0.013 [0.0384, 0.0476] |
The confidence intervals are disjoint on all three metrics.
Response to Reviewer ttAK (2/2)
W4 — Computational analysis
We appreciate this request and extend our computational report.
At the same resolution, KIR-NO improves reconstruction quality by 3.3 dB over the CNN (34.74 vs. 31.44 dB) with only 0.93 s of additional reconstruction time per volume (3.54 vs. 2.61 s), negligible compared with acquisition times measured in minutes.
Since our operator is resolution-agnostic, it can be trained at 128×128×80 and deployed at 256×256×160, which the fixed-grid CNN cannot do. The table below uses a KIR-NO trained at quarter resolution. The 3D E2E Varnet is trained at half resolution. The models are evaluated on SKM-TEA at half resolution.
| Training resolution | Quarter 128×128×80 | Half 256×256×160 |
|---|---|---|
| 3D E2E-VarNet (CNN) | 31.11 | 31.44 |
| KIR-NO (ours) | 34.06 | 34.74 |
Halving KIR-NO’s training resolution reduces performance by only 0.68 dB (34.74 to 34.06 dB). Even at quarter-resolution training, KIR-NO outperforms the half-resolution CNN by 2.6 dB, while requiring less time per training step and 57% less training memory (19.8 vs. 45.8 GB).
The table below shows per-volume model inference cost on a single NVIDIA GH200 GPU for BraTS 8-coil reconstruction at 4x acceleration. Each cell reports model inference time / peak GPU memory. The 2D Diffusion baseline reconstructs slices in batches of 32. The diffusion model was trained using MRI slices across all resolutions.
| Method | QR 60×60×39 | HR 120×120×78 | FR 240×240×155 |
|---|---|---|---|
| VarNet3D CNN (trained on QR) | 0.005 s / 0.12 GiB | 0.013 s / 0.80 GiB | 0.094 s / 6.32 GiB |
| VarNet3D CNN (trained on HR) | 0.005 s / 0.16 GiB | 0.014 s / 0.90 GiB | 0.095 s / 6.35 GiB |
| KIR-NO | 0.091 s / 1.28 GiB | 0.390 s / 2.18 GiB | 2.76 s / 8.88 GiB |
| Diffusion 3D (single step) | 0.19 s / 1.32 GiB | 0.77 s / 3.24 GiB | 5.46 s / 12.99 GiB |
| Diffusion 3D (multi step) | 1.15 s / 1.58 GiB | 2.31 s / 4.24 GiB | 12.37 s / 18.78 GiB |
| Diffusion 2D (single step) (batched) | 0.13 s / 0.93 GiB | 0.54 s / 1.61 GiB | 3.63 s / 4.07 GiB |
| Diffusion 2D (multi step) (batched) | 0.79 s / 0.93 GiB | 2.40 s / 1.65 GiB | 13.06 s / 4.23 GiB |
W5 — PSNR and SSIM disagreement
This is a fair observation, and we believe it reflects a real difference between the metrics rather than an inconsistency in the results. PSNR and NMSE are global metrics: they penalize any deviation in absolute intensity. SSIM is a local, normalized structural metric. A reconstruction may be structurally faithful yet achieve only modest PSNR, or intensity-accurate yet achieve only modest SSIM. Because these metrics capture complementary aspects of reconstruction quality, we report both alongside NMSE and add this clarification in the manuscript.
Q2 — BraTS synthetic vs real k-space
To clarify, BraTS uses synthetic k-space data, not real raw brain measurements. We simulate 8-coil measurements directly from magnitude images using smooth analytic (Biot–Savart-style) sensitivities, which are RSS-normalized.
In contrast, the SKM-TEA evaluation uses prospectively acquired raw k-space from clinical knee qMRI scans. We utilize the multi-coil qDESS data from the SKM-TEA raw-data track, along with the dataset's own JSENSE-estimated sensitivity maps.
This has been clarified in the manuscript.
Q3 — ROI metrics / tumour fidelity / measurements beyond PSNR, SSIM, NMSE
We agree this is the more clinically meaningful measurement, and we have added tumour-region metrics on BraTS (n = 251) for our method and the 3D CNN.
The ROI is defined volumetrically: the set of voxels whose segmentation label is > 0 in the full 3D volume, and not a bounding-box crop or a per-slice 2D region. PSNR and NMSE are evaluated over exactly those voxels; SSIM is a 3D local-window (7×7×7) SSIM map computed over the ROI voxels, so windows at the lesion boundary necessarily include some peritumoral tissue. The metrics are presented in the order: PSNR / SSIM / NMSE.
| Region | KIR-NO (ours) | 3D E2E-VarNet (CNN) |
|---|---|---|
| Whole image | 36.23 / 0.885 / 0.0217 | 26.58 / 0.757 / 0.2005 |
| Tumor ROI | 29.05 / 0.853 / 0.0170 | 20.26 / 0.290 / 0.1344 |
The lesion interior is a demanding region in which a non-reconstruction scores essentially zero, so the values in Table reflect genuine differences in lesion structure rather than a metric artifact.
The results show that
- Our normalised error is lower inside the lesion than over the whole image (0.0170 vs 0.0217), so the diagnostically relevant region is reconstructed at least as faithfully as the rest of the volume.
- The structural margin over the CNN is considerably larger inside the lesion than globally (SSIM +0.56 in the ROI vs +0.13 whole-image). Our ROI SSIM holds at 0.853 ± 0.038, while the CNN's is 0.290 ± 0.115 — a difference that a whole-image average does not reveal.
response to authors
I thank the authors for their clarification and detailed response, which partially addressed my concerns. I have updated my score accordingly.
Dear Reviewer,
Thank you for taking the time to review our rebuttal and reconsider your assessment. We appreciate that our clarifications addressed some of your concerns.
Could you please indicate which concerns remain insufficiently addressed, particularly those that are most important to your evaluation? We would be grateful for the opportunity to provide further clarification, additional analysis, or more concrete details about the revisions we plan to make within the discussion period.
- Rating
- 3/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 2/4
- Originality
- 2/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper proposes KIR-NO, a coarse-to-fine framework for accelerated 3D MRI reconstruction using resolution-agnostic local neural operators. The method combines a k-space neural-operator head, image-space neural-operator cascades, and explicit data-consistency updates, with 3D continuous DISCO-style kernels that can be sampled at different voxel resolutions. The goal is to train on memory-feasible lower-resolution 3D volumes and deploy zero-shot at higher resolution without fine-tuning. Experiments on SKM-TEA knee MRI and BraTS 2021 brain MRI compare KIR-NO against classical reconstruction methods, 2D/3D E2E-VarNet-style CNN baselines, a 3D U-Net, and limited diffusion-based baselines, reporting strong improvements across resolutions and acceleration rates together with ablations on key architectural components.
Strengths and weaknesses
Strengths
-
Applying neural operators to the low-resolution-training/high-resolution-testing setting is reasonable and effective. This is especially appealing for 3D MRI reconstruction, where resolution flexibility and volumetric modeling are closely aligned with the application.
-
The reported results are quite positive. Compared with the strong E2E-VarNet baseline and its 3D variant, KIR-NO achieves large performance gains across the main evaluated settings.
-
The continuous local-operator construction is a plausible and interesting way to improve cross-resolution transfer. The paper also provides concrete 3D kernel basis parameterizations and useful implementation details.
Weaknesses
-
The largest limitation is the experimental protocol. The paper performs downsampling/interpolation on MRI images, which may seriously disturb the k-space frequency structure. This makes the experimental evidence less rigorous and less convincing for real acquisition settings.
-
Although the main comparison against E2E-VarNet is useful, the baseline coverage is not sufficiently up to date. The paper does not compare with recent transformer/state-space/operator-based MRI reconstruction methods, such as ReconFormer or LMO (Guo et al., "ReconFormer: Accelerated MRI Reconstruction Using Recurrent Transformer," IEEE Transactions on Medical Imaging, 2024; Li et al., "LMO: Linear Mamba Operator for MRI Reconstruction," CVPR 2025).
-
Some training details are unclear. The paper claims robustness across acceleration rates, but it is not clear whether the model is trained at one sampling rate and generalized to other rates, or whether separate models are trained for each acceleration rate.
-
The paper mainly emphasizes that neural operators enable coarse-to-fine reconstruction, but this property is not unique to the proposed method. Prior neural-operator MRI reconstruction work has already studied robustness across resolutions and undersampling patterns. The authors should more clearly explain the specific novelty over existing neural-operator MRI methods, such as Jatyani et al., “A Unified Model for Compressed Sensing MRI Across Undersampling Patterns”, and Li et al., “LMO: Linear Mamba Operator for MRI Reconstruction”.
Questions
-
Beyond the coarse-to-fine motivation, the paper’s motivation relative to standard neural-operator MRI reconstruction is not fully clear. Could the authors better explain what new motivation or capability KIR-NO provides compared with prior neural-operator-based MRI reconstruction methods?
-
The paper claims robustness across acceleration rates. Are the results at 4x, 8x, and 16x obtained by training one model at a single acceleration rate and testing it across rates, or by training separate models for each acceleration rate? Please clarify the training/testing protocol.
-
Since the high-resolution protocol involves downsampling/interpolation, could the authors provide more analysis or discussion on how this preprocessing affects the k-space frequency structure and whether the observed gains would persist on truly acquired high-resolution measurements?
Limitations
Yes.
Final justification
The authors' response and additional experiments have partially addressed my concerns, especially regarding the evaluation protocol and the comparison with recent baselines. I agree that applying native 3D neural operators to MRI reconstruction is reasonable and meaningful, and the reported results suggest that the proposed method is effective. However, the coarse-to-fine capability emphasized in the title is largely an inherent property of neural operators rather than a unique feature of this specific method. Therefore, I still view the novelty as somewhat limited, and I encourage the authors to clarify and emphasize the paper’s more specific contributions, such as the native 3D operator design and reconstruction framework, in a future revision.
Formatting concerns
No major formatting concerns.
3 comments
Response to Reviewer KU44 (1/2)
We thank the reviewer for their careful and detailed review, and in particular for the concrete pointers to recent work, which helped us strengthen the empirical comparison. We address each point below.
W1 & Q3 — Does resizing disturb the k-space structure?
We welcome the opportunity to provide further clarification on the data pipeline, and refine the description in the paper accordingly. We never manipulate or interpolate k-space data directly. There was an unfortunate typo in line 300 of our manuscript (now removed), and we reiterate that there is no interpolation in k-space at any stage.
For each target resolution we (i) resize the volume in image space, (ii) transform to k-space by taking the FFT of that resized image, and (iii) apply the undersampling mask. The k-space data at every resolution is thus the exact transform of a clean image on that grid, not an interpolated spectrum. Interpolating in k-space would indeed introduce the artifacts the reviewer describes, which is precisely why we avoid it; the image-space protocol we use is the standard one in accelerated MRI, including the 2D E2E-VarNet line of work. We apologize for the typo and corrected the manuscript.
We also note that no public 3D MRI dataset provides the same anatomy acquired at multiple output resolutions, as scanning the same living subject repeatedly at varying resolutions is costly and time-consuming, creates strict hardware limits across scanner strengths, and introduces motion and biological changes over time. Thus, a cross-resolution protocol has to be constructed rather than acquired. Additionally, on SKM-TEA, the full-resolution target is 512 × 512 × 320, and the in-plane 512 × 512 grid is natively acquired. Evaluating a half-resolution-trained model there thus requires the operator to recover genuinely measured high-frequency content on a grid it never saw during training, rather than content synthesized by an upsampling step.
We will state and clarify this pipeline more explicitly in the experimental-setup section.
W2 — Comparison to new baselines (LMO, ReconFormer, 2D-NO)
We thank the reviewer for the references, and added both baselines to our evaluation. To ensure a direct and fair comparison, all models (LMO, ReconFormer, 2D-NO and our KIR-NO) are trained once at quarter resolution (128 × 128 × 80) and evaluated across all three grids with the same fixed weights.
LMO is a 2D, fixed-grid (128²) method and is competitive on its native grid; it is evaluated on the higher-resolution grids for completeness. ReconFormer and KIR-NO are evaluated on the half and full grids in a zero-shot manner, having never seen samples at these resolutions during training.
The table below shows the PSNR (dB) comparison:
| Evaluated at | LMO (CVPR'25) | ReconFormer | 2D-NO | KIR-NO (ours) |
|---|---|---|---|---|
| Quarter 128 × 128 × 80 (in-domain) | 28.89 | 30.67 | 27.13 | 32.32 |
| Half 256 × 256 × 160 (zero-shot) | 26.95 | 32.74 | 20.72 | 34.06 |
| Full 512 × 512 × 320 (zero-shot) | 26.48 | 33.08 | 20.57 | 33.66 |
KIR-NO consistently outperforms all baselines across all resolutions. Notably, at the half-resolution target (256 × 256 × 160), our method achieves 34.06 dB while training at only quarter resolution, yielding a +1.3 dB improvement over ReconFormer and a +7.1 dB improvement over LMO. We include this table in the revised manuscript.W3 & Q2 — One model for different acceleration rates
We clarify that the same single model is trained once and evaluated zero-shot across different acceleration rates 4× / 8× / 16×. Only the sampling mask changes at test time; the model weights are fixed, and no retraining or fine-tuning is performed per acceleration rate. We make this clearer and more explicit in the protocol description.
Response to Reviewer KU44 (2/2)
W3 & Q2 — One model for different acceleration rates
We clarify that the same single model is trained once and evaluated zero-shot across different acceleration rates 4× / 8× / 16×. Only the sampling mask changes at test time; the model weights are fixed, and no retraining or fine-tuning is performed per acceleration rate. We make this clearer and more explicit in the protocol description.
W4 & Q1 — Novelty compared to 2D neural-operator MRI
The novelty is not "a neural operator for MRI", since the cited works already achieve this, but rather making resolution-agnostic reconstruction work natively in 3D, driven by a problem the 2D line cannot address. The methods the reviewer cites ("A Unified Model for CS-MRI Across Undersampling Patterns" and LMO) are 2D and slice-wise, and study multi-resolution/robustness in the 2D setting. Our contribution is distinct along three axes.
(a) Problem-driven: native 3D, not 2D slice-by-slice. Clinically, volumetric acquisitions should be reconstructed as volumes, as slice-wise stacking discards through-plane consistency and fidelity which matter for lesions that span slices. However, native 3D reconstruction faces a significant practical barrier that 2D methods do not: training memory scales as , making full-volume back-propagation infeasible at clinical resolution. KIR-NO removes this barrier via its coarse-to-fine paradigm: train where back-propagation is feasible (low resolution), and deploy zero-shot at the desired high resolution. The prior 2D E2E neural-operator paper instead focuses on multi-resolution results in 2D and does not confront the 3D memory problem.
(b) New technique: native 3D DISCO and 3D filters. Resolution-agnostic 3D reconstruction requires machinery that does not exist in 2D DISCO. We design native 3D continuous kernel bases — piecewise-linear hat functions in spherical coordinates and a 3D Morlet basis — that are strictly local, anisotropy-aware (3D MRI is anisotropic), and memory-feasible on volumetric grids; a naive Cartesian 2D→3D basis is cubic in basis functions per kernel and untenable. Combined with a 3D k-space operator head, this is what enables coarse-to-fine 3D reconstruction. It is a new construction, not a re-parameterization of the 2D method.
(c) Generality beyond MRI. The result is a general resolution-agnostic 3D architecture, not an MRI-specific trick: the same 3D DISCO construction applies to other volumetric inverse problems and 3D imaging modalities (e.g., photoacoustic/CT-style tomography, 3D microscopy), where the low-resolution-train / high-resolution-deploy regime can be a natural and practical extension of the proposed method.
We now cite and discuss both works explicitly and position our contribution against them along these three axes more explicitly in the related-work section.
Dear Reviewer KU44,
Thank you for taking the time to review our rebuttal and reconsider your assessment. We appreciate that our clarifications addressed some of your concerns.
Could you please indicate which concerns remain insufficiently addressed, particularly those that are most important to your evaluation? We would be grateful for the opportunity to provide further clarification, additional analysis, or more concrete details about the revisions we plan to make within the discussion period.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
We thank the AC for the thorough and balanced summary. Below we address every point MR1–MR11 concisely; each item is discussed in greater detail in the reviewer response identified in parentheses, and the corresponding revisions have been incorporated into the manuscript.
Score context. One reviewer (ttAK) recommends acceptance with a score of 5 and rates the paper as “good” across Quality, Clarity, Significance, and Originality. We respectfully believe that the two rejection scores are primarily driven by concerns that have now been clarified or directly addressed, rather than by fundamental issues with the method or evaluation. Specifically, these concerns involve: (i) a confusion regarding the data pipeline, as our approach does not interpolate in k-space (MR1); (ii) requests for comparisons with more recent baselines, which we have now added and for which KIR-NO remains the strongest method within each resolution grid (MR3, MR4); and (iii) analyses already included in the appendix, including the component ablations in Appendix F and the matched-budget diffusion comparison in Appendix E (MR4, MR11). Importantly, the reviews recognize the paper’s central contribution, a resolution-agnostic 3D neural operator that can be trained at low resolution and deployed at high resolution, while also broadly supporting the methodological soundness of the proposed approach and its evaluation protocol.
MR1. The cross-resolution protocol preserves k-space, and the SR target is a real acquisition (→ KU44 W1/Q3; ttAK W1/Q1). We don’t interpolate in k-space. Each resolution is obtained by resizing in image space and then applying the FFT, so k-space is always the exact transform of a clean image on that grid. On SKM-TEA, the in-plane 512×512 grid is natively acquired, so KIR-NO trained on half resolution and testing on full resolution requires recovering genuinely measured high-frequency content. The confusion originates from an unfortunate typo line 300 in our manuscript, and we reiterate that there is no interpolation of k-space. We corrected the manuscript accordingly.
MR2. Robustness under realistic acquisition shifts (→ ttAK W2). New experiments evaluate: (a) measurement noise injected at sampled k-space positions, where KIR-NO leads the CNN by +1.9 to +2.9 dB PSNR at every noise level, including 8 dB, when noise-aware training is applied equally to both methods; and (b) cross-scanner transfer from SKM-TEA to fastMRI knee, where KIR-NO leads by +3.9 dB on few-shot and +3.15 dB on zero-shot.
MR3. Recent operator and transformer baselines added (→ KU44 W2; 92fo W1). Against LMO (CVPR’25), KIR-NO performs best within every grid, with gains of +3.4, +7.1, and +7.2 dB at quarter, half, and full resolution. Against ReconFormer (TMI’24) under a fully zero-shot, quarter-trained protocol, KIR-NO also leads at every grid by +1.7, +1.3, and +0.6 dB.
MR4. The diffusion comparison uses matched budgets and is not limited to an unfair appendix comparison (→ 92fo W1). Appendix E reports both single-step and 11 matched-step comparisons. KIR-NO leads in both settings, including gains of +2.5 dB over Diffusion-3D-Physics and +8.0 dB over Diffusion-CSGM in the single-step, half-resolution setting.
MR5. Novelty relative to prior neural-operator MRI methods (→ KU44 W4/Q1; 92fo W2). The cited operator- and Mamba-based CS-MRI methods are 2D or slice-wise. KIR-NO is natively 3D, combining a new function-space 3D kernel, a k-space operator head, and memory-feasible volumetric training with through-plane context. None of these elements is present in the 2D formulation.
MR6. A single model generalizes zero-shot across acceleration rates (→ KU44 W3/Q2). We clarified that the 4×, 8×, and 16× results use a single set of weights. Only the sampling mask changes at test time.
MR7. Real versus simulated k-space and high-resolution data construction (→ ttAK Q2; MR1). We clarified that SKM-TEA uses real raw multi-coil k-space, while BraTS uses simulated k-space. Multi-resolution volumes are constructed by resizing in image space and then applying the FFT.