MID: Mask-Image Distributional Divergence for Evaluating Medical Image Segmentation

Vincenzo Marcianò, XIAOMING ZHANG, Gianluca Guglielmo, Michela Antonelli, Sebastien Ourselin, Maria A Zuluaga

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

TL;DR. MID embeds 2D and 3D medical image-mask pairs jointly into a pretrained medical encoder's feature space and measures segmentation quality without requiring per-sample ground-truth reference.

Abstract. Current evaluation protocols for medical image segmentation remain largely anchored in sample-wise comparisons, e.g., Dice and Hausdorff distance, which require each prediction to be paired with a ground-truth mask. Yet two limitations arise in practice: they are inapplicable when predictions are made on unlabeled data; and even when annotations are available, they cannot assess whether a collection of predictions matches the distributional structure of the ground-truth population. We introduce MID (Mask–Image Distributional Divergence), a distribution-level evaluation metric for medical image segmentation. MID builds upon the observation that segmentation quality is a property of the joint image-mask distribution: a mask may be anatomically plausible in isolation yet incorrect for the image it accompanies. MID compares the joint distribution of images and masks between a reference set and a set of predictions, without requiring sample-wise correspondence. This captures both mask realism and image-mask consistency. We evaluate MID across 13 publicly available datasets spanning CT, MRI, and MRA. Under anatomically realistic corruptions across 56 organ groups, MID tracks mean Dice and Hausdorff distance without per-sample ground-truth pairing. MID also detects distributional shifts across modalities and anatomies, identifies image-mask misalignment through controlled shuffling experiments, and produces reliable model rankings across real segmentation models.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
20 Apr 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:45 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

This paper proposes MID, a distribution-level metric that scores medical image segmentation without per-sample ground truth. It received two accepts and one borderline accept.

I have read the authors' response, and it addressed the four priorities from my initial meta-review. On the main point, a paired-cell bootstrap on a within-organ CT subset now shows a clear and significant advantage of the joint image-mask encoding over the mask-only baseline, once organ-scale effects that had hidden it in the original table are removed. The single-Gaussian concern was answered with a Gaussian-mixture comparison whose rankings match the default estimator, so the bimodal reference does not change the model ordering. The small-sample bias was addressed with a matched-size reanalysis and explicit sample-size guidance, and the symmetry claim was corrected. The reviewer who was initially unsure raised the score and agreed the follow-ups were credible.

I recommend acceptance. The metric is well motivated, the validation across 13 datasets is thorough, the code is released, and the remaining reservations were answered from data the authors already had.

One item the authors must fix. The program chairs' citation checker flagged two references whose author lists are wrong: both cite real papers (Rad-DINO, and the topologically-faithful segmentation paper) but add people who are not authors and change or drop names. The authors must check every reference against the primary source and correct the author lists for the camera-ready. The authors should also fold the new within-organ significance analysis, the mixture-reference comparison, and the sample-size guidance into the paper.

Final justification

Accept. The rebuttal addressed all four priorities: within-organ statistical separation from the mask-only baseline (on a re-scoped subset), ranking consistency under a Gaussian-mixture reference, small-sample control with usage guidance, and the symmetry correction. The initially unsure reviewer moved to borderline accept. Two references have incorrect author lists that the authors must correct for the camera-ready.

Area Chair NhHX · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

This paper proposes MID, a distribution-level metric that scores medical image segmentation without per-sample ground truth. It received two accepts and one borderline accept.

I have read the authors' response, and it addressed the four priorities from my initial meta-review. On the main point, a paired-cell bootstrap on a within-organ CT subset now shows a clear and significant advantage of the joint image-mask encoding over the mask-only baseline, once organ-scale effects that had hidden it in the original table are removed. The single-Gaussian concern was answered with a Gaussian-mixture comparison whose rankings match the default estimator, so the bimodal reference does not change the model ordering. The small-sample bias was addressed with a matched-size reanalysis and explicit sample-size guidance, and the symmetry claim was corrected. The reviewer who was initially unsure raised the score and agreed the follow-ups were credible.

I recommend acceptance. The metric is well motivated, the validation across 13 datasets is thorough, the code is released, and the remaining reservations were answered from data the authors already had.

One item the authors must fix. The program chairs' citation checker flagged two references whose author lists are wrong: both cite real papers (Rad-DINO, and the topologically-faithful segmentation paper) but add people who are not authors and change or drop names. The authors must check every reference against the primary source and correct the author lists for the camera-ready. The authors should also fold the new within-organ significance analysis, the mixture-reference comparison, and the sample-size guidance into the paper.

Final justification

Accept. The rebuttal addressed all four priorities: within-organ statistical separation from the mask-only baseline (on a re-scoped subset), ranking consistency under a Gaussian-mixture reference, small-sample control with usage guidance, and the symmetry correction. The initially unsure reviewer moved to borderline accept. Two references have incorrect author lists that the authors must correct for the camera-ready.

1 comment
Authors · CommentOpenReview ↗

Summary for meta-reviewer

Thank you for your constructive meta-review and for the structured opportunity to provide this rebuttal. We have followed the priority list you outlined, and we would like to offer a summary below to organize our responses:

Priority 1: We have demonstrated the statistically significant advantage of the joint image-mask encoding over the mask-only baseline through a paired-cell bootstrap analysis. Details about the experimental setup and results obtained are provided in the answer to question 2 from reviewer 3hRR.

Priority 2: We have addressed the single-Gaussian assumption on bimodal references through new experiments. Details are provided in the answer to question 4 from reviewer 3hRR and question 1 from reviewer 4VEL.

Priority 3: We have investigated the small-sample bias and provided guidance on sample-size requirements for practical deployment. Please refer to question 3 from reviewer 3hRR and question 2 from reviewer 4VEL for details.

Priority 4: We have corrected the symmetry claim regarding our estimator, which arose from a typographic error in the submitted manuscript. We clarify its reference-conditioned nature in response to the limitation raised by reviewer 3hRR.

Additionally, we have provided detailed responses to all concerns raised by each reviewer. We remain available for any further questions and look forward to the remaining reviewers' feedback.

Reviewer 4VELOpenReview ↗
Rating
5/6
Confidence
3/5
Quality
4/4
Clarity
4/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper proposes a new metric called MID (Mask–Image Distributional Divergence) for evaluating medical image segmentation tasks. MID uses a pre-trained medical vision encoder to jointly encode images and the binary masks for each class, mapping them to a feature space, and then calculates the binary 2-Wasserstein distance between the reference set and the prediction set. Extensive validation across 13 public datasets (comprising a total of 56 organ groups) has demonstrated that it tracks corruption severity, detects distribution shifts, identifies image-mask misalignment, and ranks models consistently with paired metrics.

Strengths and weaknesses

Strengths

  1. Compared with metric evaluation methods that require ground truth (GT), the proposed method can be applied in scenarios where test set ground truth is unavailable, which is of particular practical value for medical images. Compared with existing evaluation methods that do not require ground truth, the proposed method does not need to train a model on each target dataset, but instead directly compares data distributions, making it scalable.
  2. The paper is well-written and well-organized, and the figures are clear.
  3. The proposed idea is simple and straightforward; as shown in Equation 2, the proposed MID borrows from the concept of FID and effectively extends it to the joint distribution space of graphs and masks.
  4. Section 3.4 is interesting; through image-mask shuffling experiments, it demonstrates that this metric is indeed capable of isolating the failure of ‘spatial correspondence’ on its own, rather than merely examining the shape of the mask.
  5. The appendix contains very detailed ablation experiments (such as those involving different backbones and sample size sensitivity analyses), and the code has already been provided.

Weaknesses

  1. When calculating the 2-Wasserstein distance, MID assumes that the projected feature space follows a normal distribution. In practice, when data from multiple organs, multiple centres or mixed modalities are aggregated into a unified Global Reference Pool, the feature distribution is often multimodal. There is a lack of discussion regarding this scenario.
  2. Appendix Table 6 shows that when the sample size n of the candidate set is less than 100, the Fréchet estimator exhibits a very pronounced positive bias in finite samples (with the mean MID rising sharply from 0.30 to 1.85). In the early stages of prospective clinical deployment, there may be only a very small number of cases, which limits the real-time application of MID in small-batch online monitoring.
Questions
  1. To what extent does the performance of MID deteriorate when multi-peaked clustering occurs in the reference pool? Can the use of a Gaussian mixture model (GMM) or non-parametric methods to estimate the Wasserstein distance alleviate this ‘domain coverage’ issue? Please provide experimental results for this scenario.
  2. Can MID be effectively applied to small-scale clinical data, or is its applicability limited to the evaluation of large datasets?
Limitations

yes

Formatting concerns

No concerns.

1 comment
Authors · RebuttalOpenReview ↗
Rebuttal

We thank the reviewer for the careful reading and constructive assessment. We address the two concerns below, which are associated with the AC's priorities on the single-Gaussian assumption and small-sample bias.

GMM and non-parametric alternatives (reviewer Q1/W1, AC priority 2). We agree that the global reference pool can be multi-modal, especially when CT and MRI, multiple anatomies, or multiple centres are pooled. To quantify whether this deteriorates MID's behaviour, we compared the default single-Gaussian MID with a two-component Gaussian-mixture variant on joint embeddings, scoring candidates with the mixture-Wasserstein upper bound of Delon–Desolneux [1]. Using the synthetic corruption setup in Appendix B, we constructed bimodal CT/MRI candidate distributions across 5 seeds and 7 severity levels. The rankings produced by the GMM and by the single-Gaussian default agree closely (mean Spearman ρ=0.99\rho = 0.99). This suggests that, in this setting, multi-peaked clustering does not materially deteriorate MID's ability to rank candidate distributions by degradation severity; its main effect is on absolute scale. We will clarify this in the Discussion: GMM variants are preferable when absolute-scale interpretability matters more than ranking, whereas the current single-Gaussian setup is appropriate when the goal is comparative ranking.

Regarding the non-parametric alternative, Appendix E already considers Kernel Inception Distance (KID) as a baseline. In the metric comparison (Table 4), KID tracks segmentation quality less well than MID (ρ=−0.28\rho = -0.28 for KID vs. −0.55-0.55 for MID against Dice), indicating that the added flexibility of a kernel estimator does not translate into a better quality signal, and that the parametric fit is preferable in this setting. Non-parametric optimal-transport estimators are an option in principle, but they are markedly more sample-hungry, which makes them less suitable for the small candidate sizes typical in this domain (Table 3).

[1] Delon, Julie, and Agnès Desolneux. "A Wasserstein-type distance in the space of Gaussian mixture models." SIAM Journal on Imaging Sciences 13.2 (2020): 936–970.

Small-scale clinical applicability and finite-sample bias (reviewer Q2/W2, AC priority 3). We agree that raw Fréchet estimates have finite-sample bias, and Table 6 quantifies this as candidate-set size varies. Building on it, our reference-size stability analysis indicates that n≥250n \geq 250 feature representations per group is sufficient for standalone use; for 50≤n<25050 \leq n < 250, a finite-sample correction changes the main quality correlations by less than 0.030.03; and for n<50n < 50, standalone assessment is not reliable. These thresholds refer to feature representations rather than scans, so n≥250n \geq 250 can correspond to roughly 60 subjects when several anatomies are monitored.

Reviewer CbnYOpenReview ↗
Rating
5/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
4/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The authors MID which is a Mask Image Distribution Divergence method for calculating the divergence of a joint image-mask pair from a reference distribution in medical image segmentation. The authors perform experiments which evaluate sensitivity to anatomically realistic segmentation corruptions, cross-dataset distributional shift, distributional metrics against per-sample geometric metrics, as well as outputs from real segmentation models.

Strengths and weaknesses
  1. The work is well motivated to an actual problem in medical image analysis, specifically in the case of segmentation. There are often more images available than labels or there is a normal propensity to use most labeled volumes as training. The authors in introducing this measure not only allow an alternative to image based measures, but also carefully demonstrate its benefits in cases where ground truth references do not exist for validation cases. This can be used as a secondary measure in addition to small curated evaluation datasets.
  2. The only seemingly missing component from the main manuscript is the dependence of the size of the reference set to the performance of MID. As is understood, MID is dependent on the scale (and perhaps the quality) of the reference in building up its reference distribution.
Questions
  1. Can the authors comment on the MedSigLIP encoder features vs those trained on specific anatomies (eg. abdomen CTs or brain MRIs) or maybe 3D foundation model features? If the generalized features are better, then the ever-growing pool of medical foundation models could be used akin to how ImageNet-trained networks have been used historically in natural images, without considering specific networks.
  2. Something that is seemingly missing from the manuscript is the sensitivity of MID to the size and label quality of the reference pool. Can the authors provide some information on where MID begins to deteriorate as it seemingly needs a good reference, similar to how pixel/voxel based measures like Dice might need high quality ground truth labels? Section 4.6 might have been where the authors presented this, but I am unable to ascertain if the authors shuffle/corrupt the reference mask-image pairs or the ones in their test set. Could the authors comment?
  3. The correlation in MID and the Mahalonobis distance in Table 2 was interesting. Can the authors comment on how the former would be better than the later in most experiments throughout the paper?
Limitations

As mentioned above, the only thing missing is the effect of the quality of the reference distribution in calculating the MID.

Final justification

I believe that the authors addressed issues admirably, but given my original already positive review, I would not like to increase the score further than what it already is.

Formatting concerns

No

3 comments
Authors · RebuttalOpenReview ↗
Rebuttal

Many thanks for the careful and detailed reading. In the following, we address the questions (Q) and the stated limitation (L1).

MedSigLIP vs. anatomy-specific / 3D encoders (Q1). We agree that the choice of encoder is important. Our backbone ablation (Appendix J) shows that MedSigLIP gives the strongest per-organ agreement with Dice (ρ=0.833\rho = 0.833), but other backbones, including BiomedCLIP, DINOv2-L, CLIP-L/14, and MAISI, preserve broadly similar ranking behaviour. This suggests that MID does not rely on anatomy-specific tuning of the encoder; rather, it requires a feature space with enough representational capacity to separate anatomy and corruption structure, which several general-purpose encoders already provide. We will make this point clearer in the main text and discuss anatomy-specific or 3D encoders as natural alternatives when available.

Clarification on Section 4.6 (Q2, L1). We thank the reviewer for spotting this ambiguity. Section 4.6 does not perturb the reference distribution: Scenarios A and B alter only the candidate set while keeping the TotalSegmentator CT reference fixed, and Scenario C compares two clean distributions. Reference-side sensitivity was therefore not tested, and we report it here.

We ran a stability study on liver features, fixing the candidate set and sweeping the reference size ∣P∣|P| over {50,100,250,500,1000}\{50, 100, 250, 500, 1000\}, with 30 bootstrap resamples per level. The estimate stabilises above ∣P∣≥250|P| \geq 250, where residual finite-sample bias falls under 25% and the bootstrap CI half-width under 12% of the value.

∣P∣\lvert P \rvert MID mean CI half-width / mean bias vs ∣P∣\lvert P \rvert=1000
50 0.025 32% +59%
100 0.023 18% +45%
250 0.020 11% +23%
500 0.017 7% +9%
1000 0.016 3% reference

We also simulated wrong-organ labelling by replacing a fraction ff of the liver reference embeddings with spleen embeddings, with reference size fixed at ∣P∣=500|P| = 500 and 20 bootstrap resamples per level.

ff contaminated MID mean 95% CI inflation vs ff=0
0.00 0 0.0173 [0.0160, 0.0193] reference
0.05 25 0.0178 [0.0165, 0.0194] +2.9%
0.10 50 0.0183 [0.0166, 0.0202] +5.8%
0.20 100 0.0196 [0.0176, 0.0219] +13.3%
0.50 250 0.0247 [0.0228, 0.0272] +42.8%

At the level tested, MID is insensitive to isolated wrong-organ labels: 5% contamination inflates the score by 2.9%, within the bootstrap CI at that reference size. It responds monotonically as contamination grows, reaching 42.8% inflation at f=0.5f = 0.5. We therefore read MID as tolerant of occasional gross labelling errors in the reference, while noting that systematic degradation does shift the score, so users who suspect systematic labelling bias should audit reference-pool provenance. We will consolidate both analyses, together with the corresponding plots, into a dedicated appendix in the final version.

MID vs. Mahalanobis and joint-metric utility (Q3). The correlation in Table 2 is expected because both metrics are anchored on the same reference Gaussian and both respond strongly to gross distributional shifts. Mahalanobis measures how far candidate points sit from the reference mean, scaled by the reference covariance. MID, through the squared 2-Wasserstein distance between Gaussian fits, contains a related mean-distance term, but also a Fréchet trace term comparing the shape of the candidate covariance to the reference covariance, which Mahalanobis does not capture. This is why the two track each other in Table 2: those shifts are dominated by movement away from the reference mean. In the main metric-comparison experiment, however, MID tracks paired segmentation quality better than Mahalanobis: MID reaches ρ=−0.55\rho = -0.55 with Dice and ρ=+0.72\rho = +0.72 with HD95, whereas Mahalanobis reaches ρ=−0.42\rho = -0.42 and ρ=+0.55\rho = +0.55. We will clarify that Mahalanobis can behave similarly under gross mean shifts, while MID adds sensitivity to changes in distributional shape.

Reviewer CbnY · CommentOpenReview ↗

Thank you for the rebutal

Thank you for the detailed rebuttal. I appreciate that the paper addresses an interesting question in an elegant way and will retain my positive score.

Authors · CommentOpenReview ↗

Many thanks for letting us know that your questions have been addressed and for confirming your positive score.

Reviewer 3hRROpenReview ↗
Rating
4/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
2/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

MID is a set-level metric for medical image segmentation that needs no per-sample ground truth at test time. It embeds each (image, per-class binary mask) pair with a frozen MedSigLIP encoder, concatenates the two embeddings, projects to a subspace fit on a labeled reference set, and reports the squared 2-Wasserstein distance between Gaussian fits of reference vs. candidate, similar to the FID estimator on joint image-mask features.

Strengths and weaknesses

Strengths:

  1. well-motivated and clearly-written
  2. thorough validation and analysis
  3. straightforward approach that's lightweight and reproducible

Weakness:

  1. Novelty is incremental. Concatenating image + conditioning embeddings before a Fréchet distance is rather a straightforward idea.
  2. The central claim rests on a gain that is not statistically separated. The paper's thesis is that the joint image-mask encoding buys what the mask channel alone cannot. But in Table 4, MID beats FID-mask by only +0.08 on Dice (rho = -0.55 vs. -0.47) and +0.11 on HD95, and the same table reports that the 95% bootstrap CIs of the two overlap in both columns.
  3. Small-sample bias is real and uncontrolled in the main comparisons. Table 6 shows mean MID falling from 1.85 (n=10) to 0.58 (n=50) to 0.30 (n>=250) — while Table 3 shows many evaluation groups are exactly this small (Spleen 41, IXI MRA 49, Lung 63, Prostate 64). The 840-cell sweep and the global-reference model ranking (Sec. 4.5) pool groups of very different sizes, so absolute MID values are not comparable across them and the cross-group correlations may partly reflect size rather than quality.
Questions
  1. when computing the joint embedding, why the mask also goes through a medical vision encoder, are there rationales for this design choice as the masks are very different from the medical image distributions and it's not sensible to use medical vision encoders to extract the mask features
  2. Is the +0.08 (Dice) / +0.11 (HD95) advantage of MID over FID-mask statistically significant (table 4)?
  3. For the small groups in Table 3 (e.g. Spleen 41, IXI 49), are the reported cross-group correlations bias-corrected or size-matched, given the finite-sample inflation in Table 6?
  4. MID fits a single Gaussian over a reference the paper itself shows is bimodal: Fig. 8 and App. I.1 state that CT datasets cluster while MRI is displaced along the dominant principal component, yet the reference pools all CT+MRI vectors under one Gaussian. Does fitting one Gaussian to a demonstrably bimodal reference distort the model rankings, and would a per-modality or GMM reference change them?
Limitations
  1. The estimator is not symmetric. The PCA map is fit on the reference, so MID(P,Q) != MID(Q,P); the Conclusion's "symmetric" claim holds for the theoretical Fréchet distance but not for the estimator as implemented.
Final justification

Rebuttal resolves the symmetry error and offers credible follow-ups on the bimodality and small-sample concerns, but only partially closes the core significance gap via a narrower re-scoped analysis.

Formatting concerns

N/A

1 comment
Authors · RebuttalOpenReview ↗
Rebuttal

Many thanks for the careful and detailed reading. We address the reviewer's concerns following the priority list suggested by the AC, and then respond to the remaining points.

Joint image-mask vs mask-only baseline (reviewer Q2, AC priority 1). The meta-reviewer asked us to show where MID improves over the mask-only baseline (FID-mask), while the reviewer correctly noted that the confidence intervals in Table 4 overlap. To address this, we ran a paired-cell bootstrap on a 38-organ CT subset (760 cells, 5000 replicates), with cells ranked within each organ before aggregation to remove between-organ scale effects. The results are as follows:

  • ∣ρ(MID)∣=0.905|\rho(\text{MID})| = 0.905
  • ∣ρ(FID-mask)∣=0.496|\rho(\text{FID-mask})| = 0.496
  • ∣Δρ∣=+0.409 [+0.358,+0.502]|\Delta\rho| = +0.409\ [+0.358, +0.502] on Dice, p<0.001p < 0.001
  • ∣Δρ∣=+0.446 [+0.372,+0.529]|\Delta\rho| = +0.446\ [+0.372, +0.529] on HD95, p<0.001p < 0.001

These effect sizes are substantially larger than the +0.08+0.08 and +0.11+0.11 differences reported in Table 4, confirming that MID's advantage is statistically significant in this controlled within-organ analysis. Between-organ scale differences can obscure the within-organ performance gap. By ranking cells within each organ before aggregation, we reduce this confounding factor and isolate the per-cell quality signal.

We also ran the same paired test against other mask-only baselines (Mahalanobis distance, KID, and MID_mask), with MID outperforming all of them at p<0.001p < 0.001, supporting the joint encoding's advantage. We will include the paired-cell bootstrap analysis in a dedicated Appendix, with Section 4.3 revised to highlight MID's statistically significant advantage over mask-only baselines after controlling for organ-size effects.

Single Gaussian on bimodal reference (reviewer Q4, AC priority 2). The reviewer asks whether fitting a single Gaussian to the CT/MRI bimodal reference distorts model rankings, while the AC asks us to address the single-Gaussian assumption on a bimodal reference.

We tested whether this bimodality changes the ordering induced by MID. We compared the default single-Gaussian estimator with a two-component GMM estimator using the synthetic corruption setup described in Appendix B and matching the CT/MRI geometry (5 seeds ×\times 7 severity levels), scoring candidates with the mixture-Wasserstein upper bound of Delon–Desolneux [1]. The induced rankings were highly consistent (mean Spearman ρ=0.99\rho = 0.99): three seeds achieved perfect alignment (ρ=1.000\rho = 1.000), while two showed only minor permutations (ρ=0.964\rho = 0.964). Thus, in this setting, the single-Gaussian approximation does not materially deteriorate the ranking of candidate distributions by degradation severity.

The main difference is in absolute scale. The single Gaussian treats the inter-mode CT/MRI separation as part of the global covariance, whereas the GMM represents the two modes separately. As a result, the single-Gaussian and GMM scores differ in magnitude, but this difference is largely monotone across severity levels in our stress test, which explains the near-identical rankings. This supports using the current single-Gaussian estimator for comparative ranking, while being cautious about interpreting absolute MID values across heterogeneous references.

We also tested nearest-mode assignment as a third alternative. This variant was less stable across seeds: candidates positioned near the boundary between modes can switch assignments under small perturbations, leading to discontinuous score changes due to differing mode-specific covariances. Thus, we will clarify that GMM-based estimators are preferable when absolute calibration across modes is required, whereas the single-Gaussian estimator remains a simple and stable choice for ranking under a fixed reference protocol.

[1] Delon, Julie, and Agnès Desolneux. "A Wasserstein-type distance in the space of Gaussian mixture models." SIAM Journal on Imaging Sciences 13.2 (2020): 936–970.

Small-sample bias (reviewer Q3, AC priority 3). The reviewer asks whether the cross-group correlations are bias-corrected or size-matched for small groups, while the AC asks us to control the small-sample bias. We agree this is an important concern, since Table 6 shows that the raw Fréchet estimator has positive finite-sample bias, and several groups in Table 3 have fewer than 100 feature representations.

We performed a matched-size analysis to test whether the reported MID-over-baseline advantages could be explained by sample-count variation rather than segmentation quality. For each organ, all candidate cells were truncated to the minimum available count before recomputing the correlations. The resulting shift in ρ\rho was <0.03< 0.03, indicating that the MID vs. baseline conclusions are not driven by sample-count variation. We will add this matched-size analysis to the Appendix.

For practical use, we will also add explicit guidance based on the sample-complexity analysis: n≥250n \geq 250 feature representations for standalone use; 50≤n<25050 \leq n < 250 with finite-sample correction; and n<50n < 50 only for exploratory or fixed-size comparative analyses.

Estimator symmetry (reviewer L1, AC priority 4). The reviewer identifies that the estimator is not symmetric as implemented, while the AC asks us to correct the symmetry claim. We agree. The theoretical squared 2-Wasserstein distance between two fixed Gaussian approximations is symmetric, but our implemented estimator fits the PCA projection on the reference distribution PP and is therefore reference-conditioned and asymmetric. The statement in the Conclusion describing MID as symmetric was a mistake, left over from an earlier version of the manuscript. We have corrected this claim.

To quantify the practical effect of this asymmetry, we compared the default estimator with a symmetric variant, MID_sym, where the PCA projection is fitted on the union P∪QP \cup Q. Across 35 candidate distributions from the corruption sweep, the absolute direction gap increased with corruption severity, from 7.8% for mild corruptions to 56.5% for severe corruptions. However, the induced ordering was unchanged in this experiment: the Spearman correlation between the default estimator and MID_sym was ρ=1.000\rho = 1.000 across seeds. Thus, the estimator is asymmetric in absolute scale, but the candidate ranking used in our experiments is preserved.

We will revise the Conclusion and checklist to describe MID as reference-conditioned rather than symmetric, and we will provide MID_sym as an optional symmetric variant for users who require symmetry.

Rationale for shared medical vision encoding (reviewer Q1). We understand the concern that binary masks and medical images have different input distributions. We use the same encoder to place image and mask representations in a common feature geometry before concatenation, avoiding hand-crafted mask descriptors while keeping the joint embedding simple and reproducible. This choice also supports the diagnostic decomposition into image, mask, and correspondence terms. Empirically, the benefit is not tied to a specific backbone: the encoder ablation in Appendix J, across MedSigLIP, BiomedCLIP, DINOv2-L, CLIP-L/14, and MAISI, shows consistent gains from joint image-mask modelling. We will clarify that the shared encoder is a pragmatic design choice, and that specialised mask encoders are a valid future direction. On novelty (reviewer W1). We agree that MID builds on the Fréchet-distance paradigm and do not claim novelty in the distance itself. The contribution is in adapting it to segmentation evaluation through joint image-mask distribution matching, where quality depends not only on mask realism but also on image-mask correspondence. The diagnostic decomposition, 2D/3D zero-shot protocol, and validation across 13 datasets distinguish MID from standard image-only or mask-only Fréchet metrics. The paired-cell bootstrap further confirms a substantial within-organ advantage over mask-only baselines.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.