potentialpaper

H-Flow: Self-supervised Human Scene Flow via Physics-inspired Joint Multi-modal Learning

Zhanbo Huang, Xiaoming Liu, Yu Kong

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

Abstract. Parametric human models capture global pose but cannot represent the non-rigid surface dynamics of clothing and soft tissue. Generic scene flow estimates dense motion but breaks down on articulated bodies, where pixel-level supervision is also intractable to acquire. We introduce H-Flow, a dense human scene flow that captures both skeletal kinematics and surface deformation. A unified multi-head transformer estimates flow from monocular video, jointly predicting pose and depth as companion outputs. The challenge lies in the lack of supervision. In place of unattainable labels, we anchor the network in the physics of human motion, encoding geometric, structural, and biomechanical priors as cross-modal training objectives. We further introduce DynAct4D, a high-fidelity synthetic benchmark providing dense flow annotations across diverse subjects, garments, and motions. On standard benchmarks, H-Flow outperforms scene-flow and parametric baselines, and generalizes zero-shot to in-the-wild video. Code, models, and the DynAct4D benchmark will be released upon publication.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
20 Apr 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:43 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

This paper received one accept, one borderline accept, and one reject, making it a borderline case. For the major weakness, the reject reviewer mentioned that the reported metrics for baseline methods including Camera-HMR, Prompt-HMR and Sam 3D Body appear inaccurate, casting uncertainty over the paper’s core advantages, and the work fails to compare its 3D flow module against recent Dust3r-inspired approaches like Align3R and Shape of Motion, substantially undermining its contribution. Also the evaluation of the paper’s main goal, recovering deformable surface dynamics such as soft tissue and clothing, is inadequate, relying only on SMPL-X labels and the poorly characterized DynAct4D dataset with unclear dynamic modeling scope. However, the other two reviewers remain overall positive as the paper is well presented with solid experiments. After reading the paper and reviews, AC feels it is possible for authors to address these concerns in the revision. AC thus gives initial positive review.

Final justification

All reviewers become positive after reading the rebuttal. AC agrees to accept.

Area Chair ECmS · Meta-reviewOpenReview ↗
Final justification
All reviewers become positive after reading the rebuttal. AC agrees to accept.
Read meta-review
Meta-review

This paper received one accept, one borderline accept, and one reject, making it a borderline case. For the major weakness, the reject reviewer mentioned that the reported metrics for baseline methods including Camera-HMR, Prompt-HMR and Sam 3D Body appear inaccurate, casting uncertainty over the paper’s core advantages, and the work fails to compare its 3D flow module against recent Dust3r-inspired approaches like Align3R and Shape of Motion, substantially undermining its contribution. Also the evaluation of the paper’s main goal, recovering deformable surface dynamics such as soft tissue and clothing, is inadequate, relying only on SMPL-X labels and the poorly characterized DynAct4D dataset with unclear dynamic modeling scope. However, the other two reviewers remain overall positive as the paper is well presented with solid experiments. After reading the paper and reviews, AC feels it is possible for authors to address these concerns in the revision. AC thus gives initial positive review.

Reviewer nPp7OpenReview ↗
Rating
5/6
Confidence
3/5
Quality
3/4
Clarity
4/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper addresses scene flow estimation of human bodies from video sequences. The authors propose a self-supervised framework based on a transformer architecture that jointly predicts depth, optical flow, human pose, and camera parameters. A key contribution is the introduction of four physics-inspired regularization terms—geometry, structure, biomechanics, and consistency—which are intuitive and well motivated. A second contribution is the DynAct4D benchmark, a synthetic dataset designed for this task. Experiments on both in-domain and out-of-domain settings demonstrate state-of-the-art performance.

Strengths and weaknesses

Strengths

  • The paper is generally well written and easy to follow.
  • It tackles a challenging problem: free-form scene flow estimation of human bodies, where rigid-motion assumptions do not hold and large-scale annotated data is difficult to obtain.
  • The overall model design is reasonable and clearly explained.
  • The four regularization terms are intuitive and appear thoughtfully designed.
  • Experimental results are comprehensive and show strong performance compared to prior methods.
  • Sufficient implementation and training details are provided in the appendix, supporting reproducibility.

Weaknesses

  • The Fit3D benchmark is used in the evaluation, but there is little to no description of it in either the main paper or Table 1. Additional background and dataset details would be helpful.
  • The evaluation primarily reports overall EPE averaged across the human body. A more detailed analysis would strengthen the paper. For example, how does performance vary across different body parts, motion types, or clothing/garment conditions? Does the proposed method consistently outperform baselines across all scenarios, or are the gains concentrated in specific cases?
  • The reported errors are relatively small (~20 mm). It would be valuable to include zoomed-in visualizations or analyses that better illustrate the spatial distribution of errors and highlight remaining failure cases.
  • Since DynAct4D is a synthetic dataset with available ground truth, it is somewhat surprising that the paper does not explore pretraining on DynAct4D followed by testing or fine-tuning on real-world datasets. Such a setup is common and seems like a natural use case for the proposed benchmark. The authors should discuss why this strategy was not considered.
  • More broadly, given that obtaining dense scene-flow ground truth from cameras is difficult, have the authors considered generating synthetic LiDAR data alongside DynAct4D? This could potentially simplify scene-flow annotation and create additional research opportunities.
  • Initially, I was surprised that the model converges to meaningful solutions given the complexity of the self-supervised objectives and regularization terms. Later, I realized that the framework includes a distillation (anchoring) mechanism. It would be helpful for the authors to more clearly explain the role of this component. Specifically, what information does the distillation process provide, and why does it prevent collapse? Are there qualitative results or visualizations showing the behavior of the model when trained without anchoring?
Questions

please refer to weakness

Limitations

I do not see discussions on limitations of the work; Broader impacts are not included in the paper either.

Final justification

My concerns regarding the fine-grained EPE analysis and the "anchoring" issue have been largely addressed, and my overall assessment remains positive toward acceptance. That said, my experience with scene flow primarily comes from application domains other than human body motion, so please weigh my comments accordingly.

Formatting concerns

No

2 comments
Authors · CommentOpenReview ↗

Response to Weaknesses and Questions

Thank you for noting the challenge of this problem setting and our regularization design. We value your thorough feedback, and address each point below; every change discussed here will be incorporated into the revision.


W1. Fit3D dataset undocumented

Fit3D is a multi-view human pose dataset focused on fitness exercises. It contains 611 sequences and roughly 3 million frames, captured with 4 synchronized RGB cameras and a VICON motion-capture system, and provides high-accuracy 3D pose and shape annotations in GHUM/SMPL-X format across dozens of fitness exercises (warm-up, barbell, dumbbell, and equipment-free categories). We will add this description to Table 1 in the revision.


W2. only aggregate EPE reported

We further compared against representative methods grouped by motion intensity and body location:

Methods 5-10mm 10-25mm 25-50mm 50-100mm >100mm
H-Flow 11.5 15.6 23.3 35.1 62.2
SAM 3D Body 19.9 26.4 33.9 54.0 118.2
Depth Pro + RAFT 3D 62.2 67.6 77.2 97.0 152.1
Methods Torso Head U Arm F Arm Hand Thigh Shin Foot
H-Flow 26.4 43.4 34.4 46.4 82.9 26.9 31.7 63.0
SAM 3D Body 30.7 39.2 43.7 66.3 88.3 29.1 31.6 64.8
Depth Pro + RAFT 3D 75.7 82.1 74.1 83.9 111.0 74.7 80.8 113.3

The advantage is largest at high motion intensity (>100mm, 47.4% lower error than SAM 3D Body) and large-displacement joints (forearm −30.0%, upper arm −21.3%). The exception is Head and Shin (43.4 vs. 39.2; 31.7 vs. 31.6), dominated by rigid rotation with weak non-rigid signal. We plan a skeletal-rotation prior for these regions in the revision, weighted in under low-deformation confidence, to fix this without hurting accuracy elsewhere.


W3. error visualization too coarse

The body-part breakdown above (W2) already shows this: error at the extremities (hand: 82.9mm, foot: 63.0mm) is markedly higher than at the torso (26.4mm), consistent with our main failure cases: lag in loose garment deformation during fast motion, and self-occlusion where the hand contacts the torso or garment. We will provide zoomed-in visualizations and per-pixel error heatmaps for these regions in the revision.


W4. no sim-to-real pretraining explored

DynAct4D's current scale and diversity were optimized for fine-grained evaluation (e.g., grouped by garment type and residual magnitude), not for the volume and variety large-scale sim-to-real pretraining needs; validating the sim-to-real domain gap also requires real-world surface trajectories as a reference, which is what our VICON rig is for. We plan to expand the dataset 10x for training, and (as noted in our response to R#3eGH) our motion-capture system will collect sparse real-world trajectories of loose-garment points to build a full sim-to-real training/test set.


W5. synthetic LiDAR not considered

We've already validated this. Since DynAct4D is built on UE5, it supports simulating point-cloud output from standard LiDAR presets (Velodyne, Ouster), including per-hit local coordinates and intensity. We will release these alongside DynAct4D.


W6. anchor mechanism's role unclear

The anchor serves two roles across training: early on, indirect guidance from external models (even if imperfect) helps H-Flow build an initial understanding of body structure it can't yet estimate on its own; later, since the proposed constraints admit both a zero solution and a genuine one (e.g., collapsing mask/pose to a single point avoids the penalty), the anchor forces valid values and blocks convergence to the zero solution.

This traces back to the design's evolution: H-Flow originally used externally pre-labeled pose/mask purely for supervision, until we found that features from the trained flow estimator could themselves decode into pose/mask via a lightweight head — letting us drop external labels and train on unlabeled data, with the anchor retained only to bridge early-stage capability and prevent the later zero-solution collapse.

The "w/o anchor" row is mislabeled; "self-supervised only" is more accurate, since the anchor constraint itself remains, just without an external teacher. In the Table 4 ablation, DINOv3 features alone, reconstructed via PCA/AutoEncoder, are sufficient to recover a coarse mask and approximate pose region. We will rename this row and provide a qualitative visualization of this self-supervised process in the revision; for the same reason, we will also replace "distillation" with "anchor" throughout the paper (see our response to R#3eGH, w2).

We welcome any further questions during the discussion period.

Reviewer nPp7 · CommentOpenReview ↗

Response to rebuttal:

Thank you for the rebuttal. My concerns regarding the fine-grained EPE analysis and the "anchoring" issue have been largely addressed, and my overall assessment remains positive toward acceptance. That said, my experience with scene flow primarily comes from application domains other than human body motion, so please weigh my comments accordingly.

Reviewer vVSEOpenReview ↗
Rating
5/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
4/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

In this paper, the authors have introduced H-Flow, which is a dense human scene flow method capturing both skeletal kinematics and surface deformation. They contributed a unified framework which can not only estimate the flow from monocular video, but also estimate the pose and depth as auxiliary outputs. To facilitate the comparison with other existing approaches, the authors also established DynAct4D benchmark, where the proposed H-Flow delivers the best performances.

Strengths and weaknesses

Strengths:

  1. The authors have contributed an important approach to the community which can achieve high fidelity dense flow estimation under in-the-wild setting. The physics inspired cross-modal coupling has a good motivation.

  2. The paper is generally well-written and the authors have provided comprehensive experiments and very nice visualizations to demonstrate the performance of the model and their idea. The method is clearly described.

  3. The proposed approach delivers promising results compared with existing approaches selected as baselines on this new benchmark with very good zero shot generalization performances.

Weaknesses:

  1. In Table 2, it would be good to report some computational overhead, e.g., inference speed, trainable parameter number and GFLOPs to have a better comparison regarding the efficiency of different approaches.

  2. As the dataset may contain different action types with different density. The authors are encouraged to group them according to the action density (e.g., the motion speed and complexity), and then report the performance per group and make comparison with baselines for these fine-grained results. That can sharpen the analysis section.

  3. I am wondering how helpful this scene flow estimated by H-Flow helps for the downstream tasks, e.g., action recognition, when we compare the results of H-Flow with the other coarsely estimated flow. The authors should somehow illustrate its potential usage in motion understanding related subfields.

Questions

My questions are fully based on the weaknesses I mentioned above.

1.Could the authors report the computational cost of H-Flow, including inference speed, the number of trainable parameters, and GFLOPs, to provide a more complete efficiency comparison with the baselines?

2.How does H-Flow perform on actions with different motion speeds, densities, and levels of complexity? A grouped evaluation by action density would provide a more fine-grained understanding of the method’s strengths and limitations.

3.Can the authors demonstrate whether the high-fidelity scene flow estimated by H-Flow benefits downstream tasks such as action recognition or motion understanding, especially compared with more coarsely estimated flow?

Limitations

The limitations are described in the conclusion section.

Final justification

The authors have addressed all my concerns and thereby I would like to raise my score to 5. I believe this contribution can be benefitial to the community.

Formatting concerns

N/A

2 comments
Authors · CommentOpenReview ↗

Response to Weaknesses and Questions

Thank you for highlighting our physics-inspired motivation and H-Flow's zero-shot generalization. We address each point below; all changes will be incorporated into the revision.


W1/Q1. missing computational efficiency comparison

Efficiency comparison with representative methods, alongside EPE on Fit3D/DynAct4D for context: Self-Mono-SF is far lighter than H-Flow but has 2×+ higher error, while SAM 3D Body and Depth Pro + RAFT 3D are both heavier and less accurate.

Methods Param (M) GFLOPs Delay (ms) FPS EPE (Fit3D) EPE (DynAct4D)
H-Flow 878.2 3,480 171.5 5.8 24.2 28.2
Self-Mono-SF 5.8 188 44.2 22.6 50.2 68.0
ZeroMSF 611.6 3,064 122.3 8.2 59.9 78.5
SAM 3D Body 1285.4 5,816 542.8 1.8 49.6 56.8
Depth Pro + RAFT 3D 957.2 39,428 1632.6 0.6 85.3 122.1

W2/Q2. no fine-grained breakdown by motion/body part

Fine-grained evaluation by motion intensity and body part, against SAM 3D Body and Depth Pro + RAFT 3D:

Methods 5-10mm 10-25mm 25-50mm 50-100mm >100mm
H-Flow 11.5 15.6 23.3 35.1 62.2
SAM 3D Body 19.9 26.4 33.9 54.0 118.2
Depth Pro + RAFT 3D 62.2 67.6 77.2 97.0 152.1
Methods Torso Head U Arm F Arm Hand Thigh Shin Foot
H-Flow 26.4 43.4 34.4 46.4 82.9 26.9 31.7 63.0
SAM 3D Body 30.7 39.2 43.7 66.3 88.3 29.1 31.6 64.8
Depth Pro + RAFT 3D 75.7 82.1 74.1 83.9 111.0 74.7 80.8 113.3

The advantage is largest at high motion intensity (>100mm, 47.4% lower error than SAM 3D Body) and large-displacement joints (forearm −30.0%, upper arm −21.3%). The exception is Head and Shin (43.4 vs. 39.2; 31.7 vs. 31.6), dominated by rigid rotation with weak non-rigid signal. We plan a skeletal-rotation prior for these regions, weighted in under low-deformation confidence, to fix this without hurting accuracy elsewhere.


W3/Q3. downstream task benefit unproven

We ran additional experiments on Action Recognition and Conditional Video Generation.

For Action Recognition, we trained the Flow-I3D flow branch directly on K400 to isolate motion-representation accuracy from network capacity effects:

Methods Top-1 Top-5
Flow-I3D Baseline (TV) 61.5 83.4
H-Flow 69.4 88.7
SAM 3D Body 66.8 88.3
Depth Pro + RAFT 3D 58.2 84.1

For video generation, we used LGC-VD conditioned on different motion representations to reconstruct 15 frames from a single starting frame on UTD-MHAD, evaluated via FVD/SSIM (human region only). The Baseline row uses 2D RAFT flow as the condition (distinct from Depth Pro + RAFT 3D below):

Methods SSIM FVD
2D RAFT 90.3 331.22
H-Flow 96.2 105.63
SAM 3D Body 94.6 164.75
Depth Pro + RAFT 3D 92.0 429.27

We welcome any further questions during the discussion period.

Reviewer vVSE · CommentOpenReview ↗

Response

Thank you very much for your rebuttal. My concers are addressed and I will raise my score.

Reviewer 3eGHOpenReview ↗
Rating
4/6
Confidence
4/5
Quality
2/4
Clarity
3/4
Significance
2/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

H-Flow is a trained model that takes a video of a person as input, and outputs a multimodal representation that includes pose information (through sparse joint keypoints) but also dense surface deformation (via scene flow and depth). It also includes a self-supervised learning objective: output modalities are mostly supervised via cross-modal physical priors (and some weak expert pseudo-labeling). Finally, the authors include a synthetic dataset as a new benchmark.

Strengths and weaknesses

Strength

  • The approach is well-motivated, the method is quite clearly explained.
  • The self-supervised constraints are sensible, and the fact that H-Flow outperforms the anchoring expert on MPJPE is a strong proof of their effectiveness.
  • The authors showcase strong results on several downstream tasks (3D flow, pose and depth estimation)

Weaknesses

  • The results reported for other methods seem completely off. For Camera-HMR on 3DPW for example, they report 56.0 and 35.1 for MPJPE and PA-MPJPE. The same could be said for Prompt-HMR, and more importantly, Sam 3D Body. This brings doubt on the main strength above.
  • For the 3D flow modality, as far as I can tell, the authors do not cite, comment or compare to any recent paper following the major shift initiated by Dust3r derivatives, such as Align3R or "shape of motion" (not accounting for D4RT as it is too recent). This weakens the paper significantly
  • It is unclear how much dynamics are modeled in the DynAct4D dataset (see questions below).
  • The central focus of the paper, reconstructing the dynamics of the deformable surface (soft tissue, clothing) is really weakly evaluated: either on SMPL-X annotations, or on the new DynAct4D dataset (see previous point).
Questions
  • How do you obtain numerical results for your baselines? How do you explain the huge gap between their original reported results and yours? This is my main concern as the significance of the paper rests on this.
  • In your ablation studies, you show results "w/o distillation anchor". Intuitively, I would expect the training to quickly collapse to a constant solution without them (zero mask, no flow, constant pose...). There is no training objective left that depends on the input as far as I can tell. Can you comment on that? Is there an extra supervision on the mask?
  • Could you provide some details on how clothing/hair is animated in DynAct4D? For example, you list BEDLAM as 'simulated' as well, but as far as I know, they only model clothing dynamics, not hair dynamics.

Minor questions and remarks:

  • The statement "Estimating dense human scene flow without ground truth is a highly ill-posed problem" appears to conflate two distinct issues. The estimation problem is inherently ill-posed due to ambiguities, whereas the absence of ground-truth annotations is a challenge for supervised training rather than a source of ill-posedness
  • From what I understand, H-Flow is trained solely from the anchors' predicted labels, without matching soft outputs, or intermediate representations. As such the method appears closer to pseudo-labeling than distillation. Can you comment on that?
  • The sentence "The four constraints above do not exhaust the full optimization" (l.210) is somewhat difficult to parse. I would suggest rephrasing.
  • You write (l.275) that you evaluate pose estimation "to verify that joint estimation does not compromise companion modality quality". Should this not be the other way around?
  • You write (l.279): "Joint estimation provides H-Flow’s pose head with the metric depth required for absolute world-space localization, a signal that dedicated pose estimators must infer indirectly from monocular cues". Could you please elaborate on that?
Limitations

Limitations could be discussed further, in particular regarding the chosen priors. For example, the center of mass prior does not always hold for dynamic motion. Or the fact that "every surface point sits within a few centimeters of an underlying bone" is not exactly true for loose clothing.

Final justification

The authors have addressed my main concerns somewhat, but I remain not fully convinced by the overall quality of the paper at this stage. Given the rating of the other two reviewers, I will concede to their points and raise my rating to borderline accept.

Formatting concerns

No concern

2 comments
Authors · CommentOpenReview ↗

Response to Major Weaknesses and Questions

Thank you for crediting our self-supervised design and H-Flow's performance. We address each point below; all changes will be incorporated into the revision.


W1/Q1. baseline numbers appear inconsistent with published results

The discrepancy comes from two factors: baselines were retrained under a unified protocol (same data/resolution/schedule), and our test set filtered out low-motion 3DPW frames (<10mm/frame) to focus on flow. The table below instead re-evaluates every baseline using its official release checkpoint and evaluation code, on the standard unfiltered 3DPW test set:

Methods MPJPE PA-MPJPE
CameraHMR 56.0 35.1
PromptHMR 58.7 36.1
SAM 3D Body 54.8 33.2
SAM 3D Body* 60.1 41.1
H-Flow* 57.7 38.0

SAM 3D Body still shows a gap (see their GitHub Issue #111). H-Flow* uses additional training data (BEDLAM, AGORA, 4DHumans, 3DPW) to match the baselines' pretraining scale. Sec. 5.2 frames pose/depth as companion outputs, not a claim of superiority over task-specific methods.


W2. missing comparison to DUSt3R-derived work

We will add DUSt3R, MonST3R, Align3R, and Shape of Motion to Related Work (D4RT as concurrent work); that line relies on per-scene optimization and produces point tracks, not dense flow. Since Align3R and Shape of Motion aren't directly comparable as-is, we benchmark against feed-forward variants from the same line:

Methods EPE Ang Err Acc@25
SpatialTrackerV2 44.3 0.489 46.6
Align3R + FlowFormer 44.3 0.432 46.1
St4RTrack 161.8 0.899 32.2
H-Flow 42.6 0.403 55.9

SpatialTrackerV2/St4RTrack anchor to frame 1, so we use a sliding window (1→2) for a fair comparison. Shape of Motion needs per-scene optimization, so we test on 10 high-motion Fit3D sequences:

Methods EPE Ang Err
Shape of Motion 81.3 0.372
SAM 3D Body 84.8 0.323
H-Flow 80.0 0.295

W3/Q3. unclear how much dynamics DynAct4D actually models

BEDLAM's hair is static mesh, not simulated as labeled; we'll correct this and separate clothing/hair dynamics. Clothing is simulated via UE Chaos Cloth with ground truth taken directly from solver output (Geometry Cache); hair uses UE Groom (strand-based, GPU). Per clothing vertex, we compare actual displacement to LBS-predicted displacement: 24.1% of deformation is non-rigid (mean 22mm/frame, peak 57mm/frame at dress hems; tight garments ≈0, so this signal comes from the 6 loose outfits of 10). Hair dynamics is currently weak (10.8mm mean displacement vs. rigid head motion) since hairstyles are mostly short; we will label this honestly and add long-hair styles in future versions.


W4. weak evaluation of deformable surface dynamics

SMPL-X has no garment DoF, and no real dataset pairs clothed humans with dense 3D flow ground truth, hence DynAct4D. Its dynamics are real, not just claimed (24.1% non-rigid, W3). We agree self-validation is the weakest link here; our VICON rig is built for exactly this cross-validation. We plan to expand garment/hair diversity in future versions.


Q2. why the anchor-free ablation doesn't collapse

This ablation replaces anchor supervision with self-supervised signals, not removes it: mask via DINOv3+AutoEncoder reconstruction, flow via photometric warp (ablation-only), pose bootstrapped from both. All three depend on input, so no collapse path exists; DINOv3 alone already recovers a coarse mask/pose, confirming this empirically. We observe degradation, not collapse. We'll rename the row to anchor → self-supervised.

Authors · CommentOpenReview ↗

Response to Minor Weaknesses

w1. ill-posedness wording conflates two concepts

This conflates two issues: estimation is ill-posed due to ambiguity, independent of supervision; missing ground truth is a separate training challenge. We'll rephrase to separate these.


w2. distillation vs. pseudo-labeling terminology

Correct — H-Flow trains on hard labels only, closer to pseudo-labeling than distillation. We'll replace "distillation" with "anchor" throughout, including in Q2's table. This reflects the design's evolution: from external pose/mask supervision to a bootstrapped form once we found flow features could themselves decode into pose/mask, with the anchor retained to prevent early-stage failure and later collapse.


w3. hard-to-parse sentence at l.210

We'll rephrase to: "The four constraints above are not the complete set of optimization terms; additional terms are described in Sec B.2."


w4. possible reversed logic at l.275

The intended meaning is that pose/depth, as by-products, should retain coarse accuracy, not the reverse. We'll rephrase, consistent with the scope in W1/Q1.


w5. metric depth claim at l.279 needs elaboration

Dedicated pose estimators lift 2D to 3D, which is scale-ambiguous, so they infer absolute scale indirectly (bone-length priors, camera assumptions). H-Flow's shared features are already metric-scale, since flow itself requires this; the pose head simply queries this point cloud via cross-attention rather than inferring scale.


Limitations. priors underdiscussed

The center-of-mass prior fails under rapid, nonlinear motion (e.g., diving); our data is concentrated on stable motion, so this isn't prominent here, but we'll discuss its bounds in an appendix. The near-bone prior indeed fails for loose garments (W3/W4: 57mm/frame at hems); one direction is adding precise optical flow supervision there, which we leave to future work.

We welcome any further questions during the discussion period.