potentialpaper

Unaligned Image Guided Denoising via Cross-modal Conditional Flow Matching

Runmin Zhang, Linshan Li, Si-Yuan Cao, Zhu Yu, Lingyu Zhu, Huaqi Zhang, Hui-liang Shen

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

Abstract. This work presents UGD-FM, a novel unaligned image guided denoising framework based on cross-modal conditional flow matching. Unlike previous approaches that assume spatially aligned inputs or only handle small-baseline rectified pairs, we address a more challenging setting where severe target noise and large-range two-dimensional cross-modal misalignment coexist. Specifically, we formulate guided denoising as a progressive flow matching process, allowing image restoration and aligned guidance aggregation to mutually reinforce each other. To support efficient few-step inference, we introduce a stage-focused and inference-consistent training strategy that focuses on task-critical denoising stages, and mitigates the training-inference mismatch. We further propose adaptive sparse guidance propagation for efficient and reliable large-range matching, regularized by perceptual and geometric auxiliary losses. Experiments demonstrate that UGD-FM achieves state-of-the-art denoising performance with only one or two inference steps, and is compatible with modern single-image restoration backbones.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
21 Apr 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 4 reviews · OpenReview

Updated 25 Nov 2026, 03:50 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

The paper introduces UGD-FM, a cross‑modal conditional flow matching framework, enabling efficient one or two‑step inference with stage‑focused training and sparse guidance propagation. Reviewers appreciated the principled design and efficiency but consistently raised concerns about limited evaluation on real-world misaligned data, missing baselines (e.g., diffusion/flow‑matching, SGDFormer), incomplete ablations of training components and hyperparameters, weak justification for perceptual consistency loss, and unclear displacement settings, leaving doubts about scalability, reproducibility, and generalization. In rebuttal, the authors have responded to the reviewers' concerns by providing additional evaluations on real-world RNS dataset, more baselines for comparisons, ablation study of training components and hyperparameters, justification of perceptual consistency loss, etc. These responses have addressed the reviewers' concerns and the final recommendation converge towards accept. The manuscript can be accepted and the authors should include these revisions in the final version.

Final justification

This submission initially received mixed ratings. In rebuttal, the authors have responded to the reviewers' concerns by providing additional evaluations on real-world RNS dataset, more baselines for comparisons, ablation study of training components and hyperparameters, justification of perceptual consistency loss, etc. These responses have addressed the reviewers' concerns and the final recommendation converge towards accept. The manuscript can be accepted and the authors should include these revisions in the final version.

Area Chair ohEv · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

The paper introduces UGD-FM, a cross‑modal conditional flow matching framework, enabling efficient one or two‑step inference with stage‑focused training and sparse guidance propagation. Reviewers appreciated the principled design and efficiency but consistently raised concerns about limited evaluation on real-world misaligned data, missing baselines (e.g., diffusion/flow‑matching, SGDFormer), incomplete ablations of training components and hyperparameters, weak justification for perceptual consistency loss, and unclear displacement settings, leaving doubts about scalability, reproducibility, and generalization. In rebuttal, the authors have responded to the reviewers' concerns by providing additional evaluations on real-world RNS dataset, more baselines for comparisons, ablation study of training components and hyperparameters, justification of perceptual consistency loss, etc. These responses have addressed the reviewers' concerns and the final recommendation converge towards accept. The manuscript can be accepted and the authors should include these revisions in the final version.

Final justification

This submission initially received mixed ratings. In rebuttal, the authors have responded to the reviewers' concerns by providing additional evaluations on real-world RNS dataset, more baselines for comparisons, ablation study of training components and hyperparameters, justification of perceptual consistency loss, etc. These responses have addressed the reviewers' concerns and the final recommendation converge towards accept. The manuscript can be accepted and the authors should include these revisions in the final version.

1 comment
Authors · CommentOpenReview ↗

Summary of Rebuttal to Area Chair

Dear Area Chair,

Thank you for summarizing the key concerns. We appreciate that the reviewers recognized the principled formulation, practical problem setting, effective few-step inference, and efficient sparse guidance propagation of UGD-FM. We conducted substantial additional experiments addressing all five prioritized points, and complete results are provided in our reviewer responses.

  1. Evaluation on real-world misaligned data. We provide an additional evaluation on the real-world RNS dataset, where UGD-FM achieves the best performance among the evaluated methods. [Reviewer 1hZU, W1 (Table R1)]

  2. Missing baselines (e.g., diffusion/flow‑matching, SGDFormer). We add comparisons with more recent approaches including SGDFormer (Inf.Fus. 2025), RFfusion (flow-matching, NeurIPS 2025), RDBM (diffusion, CVPR 2026), and 3M-TI (diffusion, CVPR 2026). Quantitative results on the RNS and FANVID datasets demonstrate that UGD-FM consistently achieves superior performance. [Reviewer 1hZU, W1 (Table R1) and W2 (Table R2)]

  3. Ablations of training components and hyperparameters. We conduct additional ablations of the training components and provide a more detailed comparison with the standard flow-matching baseline, demonstrating that both proposed training components contribute to the final performance [Reviewer qMrz, W2 (Table R2) and W6 (Table R6)]. We further provide detailed sensitivity analyses of hyperparameters including truncated Gaussian anchors τ_hc and τ_rc, standard deviation σ_s, warm-up length N_warm, top-K value, and search range D. The results show that the performance of UGD-FM does not rely on carefully tuned hyperparameters. [Reviewer 1hZU, W3 (Tables R3-R7); Reviewer qMrz, W3 (Table R4)]

  4. Justification for the perceptual consistency loss. We clarify that LPIPS is used only as an auxiliary constraint, rather than as the sole criterion for structural alignment. To assess its validity, we compare LPIPS with the modality-robust DASC descriptor for unaligned, learned-aligned, and ground-truth-aligned NIR guidance. Quantitative results demonstrate that LPIPS exhibits a trend consistent with DASC, and the LPIPS and DASC distances between learned-aligned NIR and the RGB target are substantially closer to the corresponding distances obtained with GT-aligned NIR, supporting LPIPS as a useful feature-level structural regularizer. [Reviewer qMrz, W1 (Table R1)]

  5. Displacement settings. We quantify the displacement distributions on all datasets [Reviewer qMrz, W3 (Table R3)], and provide detailed descriptions of the virtual-camera displacement settings [Reviewer qMrz, W4]. Moreover, we provide a controlled experiment on different misalignment magnitudes. Guided denoising methods such as NAID perform well only with aligned guidance or mild misalignment. In contrast, our UGD-FM maintains strong performance as the misalignment increases, demonstrating its robustness to unaligned guidance. [Reviewer qMrz, W8 (Table R8)]

Thank you again for your time. We hope the responses above address your concerns, and we would be happy to provide further clarification or additional results if needed.

Reviewer xWVtOpenReview ↗
Rating
5/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The paper proposes UGD-FM, a framework for unaligned RGB-NIR guided image denoising. The key idea is to formulate guided denoising as a cross-modal conditional flow matching process, where the noisy RGB image is progressively restored while the unaligned NIR guidance is adaptively aggregated. The method further introduces stage-focused and inference-consistent training for efficient one-step or two-step inference, and adaptive sparse guidance propagation for large-range cross-modal matching. Experiments on multiple RGB-NIR datasets show that UGD-FM improves denoising quality over both single-image denoisers and existing guided denoising methods.

Strengths and weaknesses

Strengths 1.The problem setting is meaningful. The paper addresses guided denoising under severe noise and large-range cross-modal misalignment, which is more challenging and practical than the commonly assumed aligned setting. 2.The proposed flow matching formulation is well motivated. The progressive denoising trajectory provides a reasonable way to make cross-modal matching easier as the target image becomes cleaner. 3.The experiments are comprehensive, covering multiple datasets, noise settings, and backbone choices. Weaknesses 1.The choice of (t=0.9) as the few-step inference anchor is not well justified. A sensitivity analysis over different timestep choices would make this design more convincing. 2.The method uses pseudo-flow labels from a pretrained flow model for supervision. It is unclear how much the final denoising performance depends on the accuracy of these pseudo labels. 3.The paper claims to handle large-range displacement, but the actual displacement magnitude is not clearly quantified. A comparison with prior stereo-based settings would help clarify the difficulty of the proposed setting. 4.The comparison with SANet is unclear. Since SANet is designed for stereo pairs, the paper should clarify whether it is modified to support general 2D displacement.

Questions

See above weaknesses. I would raise my score if the authors could address my concerns.

Limitations

Yes

Final justification

This paper proposes an efficient flow-matching framework for unaligned cross-modal image denoising. The rebuttal has addressed my concerns, and I recommend acceptance.

Formatting concerns

N/A.

3 comments
Authors · RebuttalOpenReview ↗
Rebuttal

Dear Reviewer xWVt, thank you for your constructive feedback and for acknowledging the practical problem setting, the well-motivated flow-matching formulation and the comprehensive experiments. We address your concerns point by point below.

W1. The choice of (t=0.9) as the few-step inference anchor is not well justified. A sensitivity analysis over different timestep choices would make this design more convincing.

We evaluate different timestep choices with t=0.3/0.5/0.7/0.9. An early anchor provides limited separation between the highly corrupted and relatively clean stages, resulting in smaller 2-step gains. When t clearly separates these stages, as with t=0.7 or t=0.9, 2-step inference yields clear and consistent improvements across the three metrics. This also shows that the improvement does not require a precisely tuned timestep. We use t=0.9 as the default.

Table R1. Sensitivity analysis over different timestep choices.

t 1-step PSNR 1-step SSIM 1-step LPIPS 2-step PSNR 2-step SSIM 2-step LPIPS
0.3 30.34 0.8432 0.2235 30.39 0.8457 0.2216
0.5 30.33 0.8412 0.2192 30.49 0.8459 0.2191
0.7 30.33 0.8409 0.2237 30.56 0.8495 0.2133
0.9 (default) 30.29 0.8401 0.2215 30.58 0.8506 0.2121

W2. The method uses pseudo-flow labels from a pretrained flow model for supervision. It is unclear how much the final denoising performance depends on the accuracy of these pseudo labels.

To evaluate the relationship between denoising performance and the quality of flow labels, we compare three types of supervision including synthetic ground-truth flow, estimated flow, and estimated flow with synthetic perturbations on the FANVID dataset. The ground-truth flow is derived from the known geometry and camera transformations used in 3DGS rendering. For the perturbed flow, we apply Gaussian blur and additive Gaussian noise to the estimated flow, increasing its mean endpoint error (EPE) by up to 15 pixels.

As shown in Table R2, replacing estimated flow with ground-truth flow improves the 2-step results by only 0.03 dB PSNR, 0.0007 SSIM, and 0.0036 LPIPS. Conversely, increasing the mean EPE by 15 pixels decreases performance by only 0.05 dB PSNR, 0.0020 SSIM, and 0.0052 LPIPS. These results indicate that denoising performance is not highly sensitive to flow-label accuracy. Flow supervision mainly serves as an auxiliary signal for learning sparse correspondence attention, rather than being a key determinant of restoration quality.

Table R2. Effect of flow-label quality on denoising performance.

Flow label Added mean EPE 1-step PSNR 1-step SSIM 1-step LPIPS 2-step PSNR 2-step SSIM 2-step LPIPS
Ground-truth flow - 30.31 0.8422 0.2199 30.61 0.8513 0.2085
Estimated flow (default) – 30.29 0.8401 0.2215 30.58 0.8506 0.2121
Perturbed estimated flow 5 px 30.27 0.8393 0.2232 30.56 0.8497 0.2140
Perturbed estimated flow 10 px 30.25 0.8382 0.2249 30.53 0.8487 0.2164
Perturbed estimated flow 15 px 30.25 0.8383 0.2261 30.53 0.8486 0.2173

W3. The paper claims to handle large-range displacement, but the actual displacement magnitude is not clearly quantified. A comparison with prior stereo-based settings would help clarify the difficulty of the proposed setting.

The prior stereo-based setting uses a maximum disparity/search range of 128 pixels, and searches only along the horizontal epipolar direction. In contrast, our setting involves unconstrained two-dimensional displacement, with substantial motion in both the horizontal and vertical directions.

We analyze the characteristics of 2D displacements in each dataset, and report the results in Table R3. For example, on the FANVID dataset, approximately 25% of the pixels exhibit displacement magnitudes exceeding 32.25 pixels. Covering such displacements requires a two-dimensional search window of at least 64 * 64 candidates, corresponding to nearly 4,000 candidate locations, which is substantially larger than the 128 candidates considered by a one-dimensional horizontal stereo search. Moreover, we set the default search-range hyperparameter to D=80, corresponding to an approximately 160 * 160 two-dimensional search window. This further enlarges the effective matching field to accommodate more challenging scenarios with larger displacements. These statistics quantitatively demonstrate that the proposed setting covers a substantially broader and more challenging correspondence space than the prior stereo-based approaches.

Table R3. Statistics of 2D displacements across different RGB–NIR datasets.

Dataset Image resolution (H × W) Mean (px) Std. (px) P75 (px) P90 (px) P95 (px)
FANVID 576 × 768 22.10 13.46 32.25 41.25 45.25
RGBNIR-Scene 620 × 502 – 768 × 1024 36.70 23.16 54.25 69.25 76.25
MS2 320 × 1022 29.64 12.28 36.25 43.75 50.75

W4. The comparison with SANet is unclear. Since SANet is designed for stereo pairs, the paper should clarify whether it is modified to support general 2D displacement.

In the manuscript, we directly retrain and evaluate the official SANet implementation on our datasets without modifying its architecture or search range. SANet retains its original 1D horizontal-disparity search designed for stereo pairs. To examine whether this constraint accounts for the performance gap, we further extend the search range in SANet's structure aggregation module from 1D disparity to general 2D displacement, and retrain this variant under the same protocol.

As shown in Table R4, UGD-FM substantially outperforms both the original SANet and its 2D variant. This result indicates that the performance gap is not solely explained by SANet’s original 1D search constraint, and demonstrates the effectiveness of UGD-FM for general 2D cross-modal misalignment.

Table R4. Comparison with the official and 2D variants of SANet on FANVID under Poisson-Gaussian noise (alpha=0.03, sigma=0.3).

Method PSNR↑ SSIM↑ LPIPS↓
SANet (official) 28.92 0.8029 0.3651
SANet (2D) 29.15 0.8101 0.3357
UGD-FM (NAFNet, 1-step) 30.12 0.8351 0.2351
UGD-FM (NAFNet, 2-step) 30.42 0.8458 0.2237
UGD-FM (Restormer, 1-step) 30.29 0.8401 0.2215
UGD-FM (Restormer, 2-step) 30.58 0.8506 0.2121
Reviewer xWVt · CommentOpenReview ↗

Thank the authors for their rebuttal and the additional experimental results. The rebuttal has addressed my concerns, including the ablation studies on timestep selection and flow-label quality, as well as the clarification and experiments regarding displacement settings. I have also reviewed the comments and rebuttal responses from the other reviewers. Given that no significant flaws remain, I will raise my score to accept.

Authors · CommentOpenReview ↗

Dear Reviewer xWVt,

Thank you for your careful review. We are glad that our responses addressed your concerns and will revise the manuscript accordingly.

Reviewer FxYVOpenReview ↗
Rating
5/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The paper studies unaligned image guided denoising with noisy RGB inputs and spatially misaligned NIR guidance. It proposes UGD-FM, which combines conditional flow matching with cross-modal guidance aggregation. Instead of directly mapping the noisy input and guidance image to the clean output, the method performs progressive restoration along a flow trajectory. To support few-step inference, the authors design a stage-focused training strategy and construct inference-consistent intermediate states. They also propose sparse coarse-to-fine guidance propagation to handle large 2D displacement efficiently. Experimental results show consistent improvements on RGB-NIR Scene, FANVID, and MS2 datasets.

Strengths and weaknesses

Strengths

1.The paper targets an important limitation of existing RGB-NIR guided denoising methods, which mostly assume spatially aligned inputs or are limited to small-baseline stereo pairs.

2.The overall framework is clearly designed. The combination of progressive flow-based restoration and guidance aggregation fits the unaligned denoising problem well.

3.The stage-focused and inference-consistent training strategy is a reasonable design for making flow matching effective with only one or two inference steps.

4.The quantitative results are strong and consistent across several datasets and noise levels, and the ablation study supports the usefulness of the main components.

Weaknesses

1.The paper lacks ablations on key hyperparameters, such as the attention window size, top-K selection, and the choice of t=0.9.

2.It would be beneficial to explore whether the framework can extend to other unaligned guided restoration tasks, such as guided image super-resolution.

3.Since the proposed method is based on flow matching, comparisons with diffusion-based or flow-matching-based restoration methods would make the evaluation more complete.

Questions

Please refer to the concerns raised in the Weaknesses section.

Limitations

Yes

Final justification

The additional hyperparameter ablations, analysis of guided super-resolution, and further comparisons have addressed my concerns. I therefore maintain my accept rating.

Formatting concerns

No

3 comments
Authors · RebuttalOpenReview ↗
Rebuttal

Dear Reviewer FxYV, thank you for your thoughtful review and for recognizing that our work addresses an important limitation, presents a clearly designed framework, enables effective few-step flow matching, and achieves strong and consistent results. Below, we address your questions point by point.

W1. The paper lacks ablations on key hyperparameters, such as the attention window size, top-K selection, and the choice of t=0.9.

Attention window size. We vary the attention window size from 32 to 96. A small window may fail to cover the true disparity range, causing a clear performance drop, while increasing the window size generally improves performance by providing a broader search range.

Table R1. Ablation on attention window size.

Window size 1-step PSNR 1-step SSIM 1-step LPIPS 2-step PSNR 2-step SSIM 2-step LPIPS
32 30.19 0.8377 0.2241 30.42 0.8424 0.2179
48 30.29 0.8396 0.2167 30.49 0.8471 0.2105
64 30.32 0.8413 0.2179 30.56 0.8527 0.2097
80 (default) 30.29 0.8401 0.2215 30.58 0.8506 0.2121
96 30.31 0.8403 0.2221 30.61 0.8507 0.2128

Top-K selection. We vary K from 1 to 7. A small K may discard plausible correspondences, causing a clear performance drop. Increasing K consistently improves performance. We therefore use K=5 to balance accuracy and efficiency.

Table R2. Ablation on top-K selection.

Top-K 1-step PSNR 1-step SSIM 1-step LPIPS 2-step PSNR 2-step SSIM 2-step LPIPS
1 29.89 0.8248 0.2449 30.19 0.8364 0.2345
3 30.26 0.8382 0.2264 30.55 0.8492 0.2159
5 (default) 30.29 0.8401 0.2215 30.58 0.8506 0.2121
7 30.30 0.8417 0.2185 30.59 0.8520 0.2110

Choice of t=0.9. We vary the time anchor t for two-step inference from 0.3 to 0.9. An early anchor provides limited stage separation and thus smaller 2-step gains. When t establishes a clear boundary between the highly corrupted and relatively cleaner stages, 2-step inference yields clear performance gains, as observed at t=0.7 and t=0.9. Their comparable results also indicate that performance is not sensitive to the exact value of t.

Table R3. Ablation on the time anchor t for two-step inference.

t 1-step PSNR 1-step SSIM 1-step LPIPS 2-step PSNR 2-step SSIM 2-step LPIPS
0.3 30.34 0.8432 0.2235 30.39 0.8457 0.2216
0.5 30.33 0.8412 0.2192 30.49 0.8459 0.2191
0.7 30.33 0.8409 0.2237 30.56 0.8495 0.2133
0.9 (default) 30.29 0.8401 0.2215 30.58 0.8506 0.2121

W2. It would be beneficial to explore whether the framework can extend to other unaligned guided restoration tasks, such as guided image super-resolution.

We extend UGD-FM to RGB guided thermal image super-resolution following the 3M-TI protocol[1]. UGD-FM achieves the best SSIM and MUSIQ, while obtaining competitive PSNR and perceptual quality, validating the generalizability and extensibility of our framework.

Table R4. Comparison on RGB guided thermal image super-resolution.

Method PSNR↑ SSIM↑ LPIPS↓ MANIQA↑ MUSIQ↑
CoRPLE 30.47 0.8642 0.3206 0.2833 30.46
SeeSR 29.41 0.8495 0.1828 0.4278 35.22
3M-TI 30.09 0.8610 0.1787 0.4443 36.66
UGD-FM (Ours) 30.36 0.8710 0.2012 0.4008 36.94

W3. Since the proposed method is based on flow matching, comparisons with diffusion-based or flow-matching-based restoration methods would make the evaluation more complete.

We compare UGD-FM with 3M-TI[1], RFfusion[2], and RDBM[3] on the FANVID dataset under Poisson-Gaussian noise (alpha=0.03, sigma=0.3). 3M-TI and RFfusion are cross-modal image restoration/fusion approaches based on diffusion and rectified flow, respectively. RDBM is a diffusion-based single image restoration method. UGD-FM consistently achieves the best performance among the diffusion and flow matching based methods.

Table R5. Comparison with diffusion and flow matching methods.

Method PSNR↑ SSIM↑ LPIPS↓
RDBM (diffusion) 28.80 0.7828 0.3535
RFfusion (flow matching) 28.53 0.7702 0.3251
3M-TI (diffusion) 28.89 0.7872 0.3221
UGD-FM (NAFNet, 1-step) 30.12 0.8351 0.2351
UGD-FM (NAFNet, 2-step) 30.42 0.8458 0.2237
UGD-FM (Restormer, 1-step) 30.29 0.8401 0.2215
UGD-FM (Restormer, 2-step) 30.58 0.8506 0.2121

References

[1] 3M-TI: High-Quality Mobile Thermal Imaging via Calibration-free Multi-Camera Cross-Modal Diffusion. CVPR, 2026.

[2] Efficient Rectified Flow for Image Fusion. NeurIPS, 2025.

[3] Residual Diffusion Bridge Model for Image Restoration. CVPR, 2026.

Reviewer FxYV · CommentOpenReview ↗

I thank the authors for their rebuttal. The additional hyperparameter ablations, analysis of guided super-resolution, and further comparisons have addressed my concerns. I therefore maintain my accept rating.

Authors · CommentOpenReview ↗

Dear Reviewer FxYV,

Thank you for your careful review. We are glad that our responses addressed your concerns and will revise the manuscript accordingly.

Reviewer qMrzOpenReview ↗
Rating
4/6
Confidence
4/5
Quality
2/4
Clarity
2/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper proposes UGD-FM, a conditional flow-matching framework for unaligned image-guided denoising. The key idea is to leverage unaligned NIR guidance images as structural guidance to restore noisy RGB images. The framework is designed to be compatible with classical single-image restoration backbones, such as NAFNet, Uformer, and Restormer. The proposed method achieves strong performance with only one or two inference steps on both synthetic and real datasets. However, I find that the paper still has several weaknesses in three aspects: the design and justification of the loss functions, the presentation and completeness of the ablation studies, and the sufficiency of the experimental validation and comparisons.

Strengths and weaknesses

Strength

  1. The motivation is reasonable and practically relevant. In real imaging systems, NIR guidance images and noisy RGB inputs are often captured by different sensors, so perfect spatial alignment is difficult to guarantee.
  2. The proposed sparse guidance propagation is a useful design choice for reducing the cost of large-range cross-modal matching. Instead of performing exhaustive dense matching, the method focuses on a small set of high-confidence candidates.
  3. The few-step conditional flow-matching formulation is also computationally attractive. Achieving competitive denoising results with only one or two inference steps makes the framework more efficient than many iterative generative restoration approaches.

Major Weakness

  1. The perceptual consistency loss is not well justified. It uses LPIPS between aligned NIR guidance and clean RGB images, but LPIPS does not explicitly measure structural consistency and may be affected by cross-modal appearance differences. The paper also lacks visualization showing that the aligned NIR guidance is structurally correlated with the RGB target.
  2. The motivation that standard flow matching may suffer from error accumulation with more solver steps is not sufficiently supported. The paper lacks a direct and systematic comparison with a standard flow-matching baseline under different numbers of inference steps, making it unclear whether the proposed stage-focused and inference-consistent training strategy is necessary.
  3. The search range (D=80) is not justified. The paper does not explain whether this value comes from displacement statistics, camera geometry, validation tuning, or empirical choice. It also lacks sensitivity analysis over different search ranges.
  4. The virtual-camera displacement range used to synthesize misaligned RGB-NIR pairs is not reported. Therefore, it is unclear how severe the synthetic misalignment actually is and how it relates to the model’s (D=80) search range.
  5. The comparison lacks the closely related SGDFormer baseline, even though the paper discusses it as related work and adopts a similar spatially variant fusion idea. More broadly, the experimental comparison does not sufficiently cover recent 2025 related works.
  6. The two proposed training components, stage-focused time sampling and inference-consistent state construction, are not separately ablated. It is unclear which component contributes to the reported improvement.
  7. The global-attention ablation is weak because it only reports OOM. This does not show that the proposed sparse propagation is better than practical alternatives such as window attention.
  8. Several guided baselines perform worse than single-image denoisers, but the paper does not analyze this sufficiently. More controlled experiments, such as aligned vs. unaligned guidance, oracle-aligned guidance, wrong guidance, or performance by misalignment magnitude, are needed.

Minor Weakness

The ablation study section discusses the ablation results but does not explicitly refer to Table 4.

Questions
  1. Can the authors provide more justification for the perceptual consistency loss? In particular, why is LPIPS between aligned NIR guidance and clean RGB an appropriate structural regularizer despite cross-modal appearance differences? Visualization or quantitative evidence of structural correlation would help.
  2. Can the authors clarify and justify the displacement settings? This includes the choice of (D=80), the virtual-camera displacement range used for synthetic misalignment, and whether actual displacement statistics are available.
  3. Can the authors provide additional ablations for the training strategy? Separately evaluating stage-focused time sampling and inference-consistent state construction, as well as comparing against a standard flow-matching baseline with different inference steps, would clarify whether these components are necessary.
  4. Can the authors strengthen the experimental comparison? In particular, adding SGDFormer or other recent 2025 related baselines, and replacing the global-attention OOM comparison with practical alternatives such as window attention would make the comparison more convincing.

My evaluation would increase if the authors provide convincing evidence for the displacement setting, stronger ablations for the training components, and fairer comparisons with recent guided denoising or cross-modal matching methods. It would decrease if these issues remain unsupported or are only addressed qualitatively.

Limitations

No. The authors mention occlusion under severe parallax and additional computational overhead, but they do not discuss a more important limitation: the method depends on many manually chosen hyperparameters, such as (D), sampling anchors, sampling variance, warm-up schedule, and Top-K. These choices lack sufficient ablation support, which makes the method’s generalization to other datasets or sensor setups uncertain.

Final justification

The rebuttal and follow-up discussion substantially addressed my main concerns. The authors provided additional justification and sensitivity analysis for the displacement range, added comparisons with recent methods and practical attention baselines, clarified the cumulative ablation of the two training components, and evaluated robustness under different misalignment magnitudes. Regarding the perceptual consistency loss, the authors appropriately clarified that lpcl_{pc}​ is an auxiliary feature-space regularizer rather than a modality-invariant structural or geometric constraint, and committed to revising the corresponding claim. While the cross-modal validity of LPIPS remains supported mainly by empirical evidence rather than a strong theoretical justification, I consider this a remaining but limited concern. Overall, the rebuttal resolves most of the issues that previously motivated my rejection, but some methodological justification remains incomplete. Balancing these aspects, I recommend Borderline Accept.

Formatting concerns

None

5 comments
Authors · RebuttalOpenReview ↗
Rebuttal

Dear Reviewer qMrz, thank you for your constructive feedback and for acknowledging the reasonable motivation of our work, the useful design choice of sparse guidance propagation, and the computationally attractive design of the few-step conditional flow-matching formulation. We address your concerns point by point below.

W1. Justification of perceptual consistency loss.

We clarify that LPIPS is used only as an auxiliary constraint to facilitate sparse-attention learning, rather than as the sole criterion for structural alignment. To quantitatively assess its validity, we measure LPIPS, L1, and DASC[1] distances between the RGB target and different NIR guidance. DASC is a modality-robust self-similarity descriptor for multi-modal correspondence. As shown in Table R1, compared to L1, LPIPS exhibits a trend consistent with DASC, and the LPIPS and DASC distances of learned-aligned NIR to the RGB target are substantially closer to those of GT-aligned NIR. These results support LPIPS as a useful feature-level structural regularizer.

Due to the rebuttal restrictions, we cannot provide visualizations here. We will include them in the revised manuscript.

Table R1. Cross-modal structural consistency.

Guidance LPIPS↓ L1↓ DASC↓
Unaligned NIR 0.48±0.05 0.15±0.06 0.28±0.04
Learned-aligned NIR 0.34±0.04 0.12±0.05 0.15±0.04
GT-aligned NIR 0.28±0.05 0.13±0.05 0.10±0.04

W2. Comparison with a standard flow-matching baseline under different numbers of inference steps.

We provide a detailed comparison in Table R2. Standard FM yields consistent gains from 1 to 4 solver steps. However, at 8 steps, PSNR and SSIM drop, while LPIPS improves, indicating that additional steps do not consistently improve restoration quality. We attribute the fidelity degradation to error accumulation during iterative forward-Euler updates, which may cause global blur and detail loss. This observation is consistent with previous works like FlowIE[2]. In contrast, UGD-FM employs stage-focused and inference-consistent training for efficient inference, achieving SOTA performance with only 2 steps.

Table R2. Comparison under different inference steps.

Method Steps PSNR↑ SSIM↑ LPIPS↓
Standard FM 1 30.28 0.8389 0.2357
Standard FM 2 30.34 0.8401 0.2312
Standard FM 4 30.36 0.8422 0.2291
Standard FM 8 30.02 0.8340 0.2265
UGD-FM 1 30.29 0.8401 0.2215
UGD-FM 2 30.58 0.8506 0.2121

W3. Justification of the search range (D=80) and sensitivity analysis over different search ranges.

Choice of D=80. We use D=80 as a general search range to cover the vast majority of 2D displacements.

Statistics of 2D Displacements. Table R3 summarizes the displacement distributions across datasets. For the synthetic FANVID and RGBNIR-Scene datasets, we obtain ground-truth flow from 3DGS rendering. For the real-world MS2 dataset, we estimate flow using CrossModalRAFT. The P95 displacements are 45.25, 76.25, and 50.75 pixels, respectively. Thus, the search region [-80,80]^2 covers almost all regions.

Sensitivity analysis. We conduct ablation on FANVID dataset by varying D from 32 to 96. Table R4 shows that a small window may fail to cover the true disparity range, causing a clear performance drop, while increasing the window size generally improves performance by providing a broader search range.

Table R3. Statistics of 2D displacements.

Dataset Resolution(H×W) Mean(px) Std.(px) P75(px) P90(px) P95(px)
FANVID 576×768 22.10 13.46 32.25 41.25 45.25
RGBNIR-Scene 620×502–768×1024 36.70 23.16 54.25 69.25 76.25
MS2 320×1022 29.64 12.28 36.25 43.75 50.75

Table R4. Ablation on search range DD on FANVID.

D 1-step PSNR 1-step SSIM 1-step LPIPS 2-step PSNR 2-step SSIM 2-step LPIPS
32 30.19 0.8377 0.2241 30.42 0.8424 0.2179
48 30.29 0.8396 0.2167 30.49 0.8471 0.2105
64 30.32 0.8413 0.2179 30.56 0.8527 0.2097
80(default) 30.29 0.8401 0.2215 30.58 0.8506 0.2121
96 30.31 0.8403 0.2221 30.61 0.8507 0.2128

W4. Virtual-camera displacement range for synthesizing misaligned RGB-NIR pairs.

We place the virtual cameras on a circular trajectory whose radius is normalized so that the nominal translational parallax of points at a representative near-scene depth is approximately x% of the image diagonal. We use x=6 for FANVID and x=8 for the RGB-NIR Scene benchmark, with the latter yielding a wider camera baseline and thus stronger cross-view misalignment. These values are fixed for each benchmark and are not tuned on a per-sample basis. Please refer to W3 and Table R3 for a detailed analysis of 2D displacements.

W5. Comparison with SGDFormer and recent 2025 related works.

We compare UGD-FM with recent methods, including SGDFormer, 3M-TI[3], RDBM[4], and RFfusion[5], as reported in Table R5. UGD-FM consistently outperforms these baselines, demonstrating its effectiveness for unaligned guided denoising.

Table R5. Comparison with recent approaches.

Method PSNR↑ SSIM↑ LPIPS↓
SGDFormer (Inf.Fus. 2025) 28.98 0.7949 0.3780
RDBM (CVPR 2026) 28.80 0.7828 0.3535
RFfusion (NeurIPS 2025) 28.53 0.7702 0.3251
3M-TI (CVPR 2026) 28.89 0.7872 0.3221
UGD-FM (NAFNet, 1-step) 30.12 0.8351 0.2351
UGD-FM (NAFNet, 2-step) 30.42 0.8458 0.2237

W6. Ablation of training components.

We ablate training components in Table R6. Stage-focused sampling aligns the training-time distribution with the fixed inference anchors, improving 2-step performance. Inference-consistent state construction further aligns the training and inference states by replacing the interpolation state with a solver-induced state. We note that training-time rollout of inference states is particularly practical with few-step fixed inference timesteps, consistent with the short-horizon rollout design in recent world models[6].

Table R6. Ablation on training components.

Training 1-step PSNR 1-step SSIM 1-step LPIPS 2-step PSNR 2-step SSIM 2-step LPIPS
Standard FM 30.28 0.8389 0.2357 30.34 0.8401 0.2312
+Stage-focused sampling 30.31 0.8396 0.2238 30.42 0.8421 0.2224
+Inference-consistent states 30.29 0.8401 0.2215 30.58 0.8506 0.2121

W7. Ablation of attention module.

We compare our sparse propagation with no attention and window attention, and list the results in Table R7. Without attention, the model cannot handle spatial misalignment, leading to large performance drop. Window attention provides a non-local receptive field but is less flexible. In contrast, our sparse propagation efficiently searches a large displacement range, and achieves the best performance.

Table R7. Ablation on guidance aggregation.

Aggregation 1-step PSNR↑ 1-step SSIM↑ 1-step LPIPS↓ 2-step PSNR↑ 2-step SSIM↑ 2-step LPIPS↓
No attention 28.97 0.7920 0.3247 29.10 0.7976 0.3244
Window attention 29.64 0.8188 0.2512 30.03 0.8370 0.2369
Sparse propagation 30.29 0.8401 0.2215 30.58 0.8506 0.2121

W8. Analysis of guided baselines and more controlled experiments on misalignment magnitudes.

Analysis. Most guided baselines assume aligned inputs, and thus cannot effectively use guidance under large misalignment. They also often have fewer parameters than single-image denoisers, limiting their performance when the guidance branch fails. This observation also highlights the motivation and contribution of UGD-FM. We note that similar results are reported in previous works like SANet and RFFNet.

Experiments on misalignment magnitudes. We conduct comparisons at different misalignment levels on FANVID and report the results (PSNR/SSIM/LPIPS) in Table R8. The parameter x follows the virtual-camera displacement definition in W4, with a larger x indicating stronger misalignment. Guided denoising methods like NAID perform well only with aligned guidance or mild misalignment. In contrast, our UGD-FM maintains strong performance as the misalignment increases, demonstrating its robustness to unaligned guidance.

Table R8. Comparison of different misalignment magnitudes.

Aligned x=2 x=4 x=6 x=8
Restormer 29.20/.7981/.3497 — — — —
NAID 31.93/.8961/.1616 29.22/.8071/.2919 29.05/.7970/.3324 28.99/.7933/.3540 28.97/.7922/.3673
UGD-FM (NAFNet, 1-step) 31.75/.8898/.1771 30.50/.8478/.2129 30.29/.8409/.2250 30.12/.8351/.2351 29.97/.8297/.2448
UGD-FM (NAFNet, 2-step) 32.06/.8984/.1535 30.86/.8597/.1988 30.62/.8523/.2119 30.42/.8458/.2237 30.24/.8394/.2352

Minor Weakness. Reference of Table 4.

Thank you. We will correct it in the revised manuscript.

Q1. Justification for the perceptual consistency loss.

Please refer to W1.

Q2. Clarification of displacement settings.

Please refer to W3 and W4.

Q3. Ablation of training strategies and comparison with flow-matching baseline with different inference steps.

Please refer to W2 and W6.

Q4. Comparison with recent baselines and window attention variant.

Please refer to W5 and W7.

Limitations. Ablation for hyperparameters.

Please refer to W3 and Table R4 for the ablation of search range D. For other hyperparameters including sampling anchors, sampling variance, warm-up schedule, and Top-K, please refer to the rebuttal to Reviewer 1hZU (W3). These results show that the performance of UGD-FM does not rely on carefully tuned hyperparameters.

References

[1] DASC: Dense Adaptive Self-Correlation Descriptor for Multi-modal and Multi-spectral Correspondence. CVPR, 2015.

[2] FlowIE: Efficient Image Enhancement via Rectified Flow. CVPR, 2024.

[3] 3M-TI: High-Quality Mobile Thermal Imaging via Calibration-free Multi-Camera Cross-Modal Diffusion. CVPR, 2026.

[4] Residual Diffusion Bridge Model for Image Restoration. CVPR, 2026.

[5] Efficient Rectified Flow for Image Fusion. NeurIPS, 2025.

[6] Self Forcing: Bridging the Train-Test Gap in Autoregressive Video Diffusion. NeurIPS, 2025.

Reviewer qMrz · CommentOpenReview ↗

Follow-up questions

Thank you to the authors for addressing my concerns. I am considering increasing my score; however, I still have the following questions regarding the current rebuttal.

  1. Regarding W1, I do not think the response fully addresses my concern. The key issue is whether an off-the-shelf LPIPS feature space is appropriate for measuring structural consistency between RGB and NIR images. The consistent ordering of LPIPS and DASC only suggests that LPIPS is somewhat sensitive to alignment quality; it does not demonstrate that LPIPS primarily captures structural information or that its gradients promote more accurate correspondence learning. Since LfmL_{\mathrm{fm}} supervises RGB restoration and LfcL_{\mathrm{fc}} constrains displacement, the specific role of LpcL_{\mathrm{pc}} remains unclear. At minimum, I suggest avoiding the claim that LpcL_{\mathrm{pc}} directly enforces structural consistency unless stronger evidence is provided.

  2. Regarding Table R6, could the authors clarify whether the reported ablations are independent or cumulative? From the “+” notation, the settings appear to be:

    1. Standard FM;
    2. Standard FM + stage-focused sampling;
    3. Standard FM + stage-focused sampling + inference-consistent states.

    If this interpretation is correct, Table R6 only evaluates inference-consistent state construction on top of stage-focused sampling, rather than assessing its standalone contribution. Is inference-consistent state construction inherently dependent on the qrcq_{\mathrm{rc}} distribution introduced by stage-focused sampling? If not, why is the “Standard FM + inference-consistent states only” setting omitted?

Authors · CommentOpenReview ↗

Response to follow-up questions

Dear Reviewer qMrz,

Thank you for your feedback and follow-up questions. We address them below.

Regarding W1 (Justification of perceptual consistency loss)

Thank you for this important clarification. We agree that the consistent LPIPS–DASC ordering only suggests that LPIPS is sensitive to alignment quality, and it does not establish LPIPS as a modality-invariant structural metric.

In our framework, LpcL_{\mathrm{pc}} is used as an auxiliary feature-space regularizer. Explicit displacement supervision is provided by LfcL_{\mathrm{fc}}, while LfmL_{\mathrm{fm}} supervises RGB restoration. Thus, LpcL_{\mathrm{pc}} does not independently enforce geometric correspondence, but encourages perceptual feature-space compatibility between the aggregated guidance and the RGB target. Its complementary effect is empirically supported by the improvements in Table 4. Adding LpcL_{\mathrm{pc}} improves the one-step PSNR/SSIM/LPIPS from 30.13/0.8355/0.2306 to 30.29/0.8401/0.2215, and the two-step results from 30.45/0.8465/0.2217 to 30.58/0.8506/0.2121.

One possible explanation is that pretrained deep features can encode perceptually meaningful information beyond pixel-wise differences, as observed in the original LPIPS study [1]. Related cross-modal works provide indirect supporting evidence. CrossModalFlow [2] adapted a single-modal optical flow network to diverse cross-modal scenarios using synthetic data augmentations generated from RGB videos, while SANet [3] used a pretrained VGG-16 perceptual loss for cross-spectral structure aggregation. These studies motivate our use of an auxiliary deep feature-space constraint.

Following your suggestion, we will replace “directly enforces structural consistency” with “serves as an auxiliary perceptual regularizer that encourages feature-space compatibility.”

Regarding Table R6 (Ablation of training components)

Thank you for the careful reading. Your interpretation is correct, and the rows in Table R6 are cumulative.

Inference-consistent state construction requires the inference solver and its timestep schedule to be specified first. Therefore, in our framework, it is introduced on top of stage-focused sampling. Standard FM samples training timesteps uniformly from [0,1][0,1], whereas inference evaluates the model at a fixed set of timesteps determined by the solver and the number of inference steps. Stage-focused sampling first aligns the training timestep distribution with these fixed inference timesteps. In particular, qrcq_{\mathrm{rc}} identifies the relatively cleaner stage reached after the first solver update. Inference-consistent state construction then simulates this solver update for samples from qrcq_{\mathrm{rc}}, aligning the training states with those actually encountered during inference. Thus, in our formulation, inference-consistent state construction is coupled with qrcq_{\mathrm{rc}}, rather than being a standalone component under uniform timestep sampling. Removing stage-focused sampling would require introducing a separate rule to select inference-relevant timesteps. Therefore, we did not include the “Standard FM + inference-consistent states only” setting.

A conceptually similar strategy is adopted in recent autoregressive video-generation and world-model frameworks [4, 5]. They first specify a fixed few-step inference schedule, such as a 2-step or 4-step schedule, and then introduce self-forcing or self-rollout to construct the states encountered during inference and use them during training.

We hope these responses address your concerns, and we would be happy to provide further clarification or discuss any additional questions.

References

[1] The Unreasonable Effectiveness of Deep Features as a Perceptual Metric. CVPR, 2018.

[2] Promoting Single-Modal Optical Flow Network for Diverse Cross-modal Flow Estimation. AAAI, 2022.

[3] Structure Aggregation for Cross-Spectral Stereo Image Guided Denoising. CVPR, 2023.

[4] Self Forcing: Bridging the Train-Test Gap in Autoregressive Video Diffusion. NeurIPS, 2025.

[5] minWM: A Full-Stack Open-Source Framework for Real-Time Interactive Video World Models. arXiv, 2026.

Reviewer 1hZUOpenReview ↗
Rating
4/6
Confidence
3/5
Quality
3/4
Clarity
3/4
Significance
2/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper proposes UGD-FM, a framework for unaligned RGB-NIR guided image denoising based on cross-modal conditional flow matching. The core idea is to formulate guided denoising as a progressive flow matching process, creating a mutually reinforcing loop between image restoration and aligned guidance aggregation. To enable efficient few-step inference, a stage-focused and inference-consistent training strategy aligns training timesteps and states with task-critical denoising stages. An adaptive sparse guidance propagation mechanism reduces large-range matching from quadratic to linear complexity, regularized by perceptual and flow consistency losses. Experiments on three datasets are performed with one or two inference steps across three backbone variants.

Strengths and weaknesses

The strengths are as follows:

  1. The mutually reinforcing formulation that couples image restoration with guidance aggregation is a principled and novel design. The cleaner intermediate states naturally improve cross-modal correspondence, which in turn benefits restoration.
  2. The adaptive sparse guidance propagation effectively addresses the computational bottleneck of large-range 2D matching, reducing complexity from quadratic to linear while the global-attention ablation confirms its necessity (OOM otherwise).

The weaknesses are as follows:

  1. Two of the three datasets (FANVID and RGB-NIR Scene) use synthetically constructed misalignment via 3D Gaussian splatting parallax simulation rather than real unaligned pairs. Only MS2 provides natural misalignment, raising concerns about how well results generalize to real-world dual-camera acquisition.
  2. The paper lacks comparison with diffusion-based or flow-matching-based guided restoration methods. Baselines are limited to regression-based single-image and guided denoisers, making it unclear whether the gains stem from the flow matching paradigm or from the guidance aggregation design alone.
  3. Key hyperparameters (truncated Gaussian anchors τ_hc, τ_rc, σ_s, warm-up length N_warm, top-K value) are fixed without sensitivity analysis, making it difficult to assess robustness and reproducibility.
  4. The method is only evaluated at 256×256 for efficiency comparison and moderate resolutions on test datasets. Scalability to high-resolution inputs and memory behavior under larger displacement ranges D are not discussed.
Questions

Could the authors provide experiments on real-world unaligned RGB-NIR pairs (beyond MS2) and a sensitivity analysis for the key hyperparameters (τ_rc, σ_s, K)?

Limitations

The method's reliance on synthetically simulated misalignment for two of three datasets and the unaddressed behavior under severe 3D parallax occlusion limit the demonstrated applicability to real-world deployment.

Final justification

Thanks for the careful response. Most of my concerns have been addressed. I have raised the score from 3 to 4.

Formatting concerns

None.

1 comment
Authors · RebuttalOpenReview ↗
Rebuttal

Dear Reviewer 1hZU, thank you for your thoughtful review and for recognizing that the mutually reinforcing formulation is a principled and novel design, and the adaptive sparse guidance propagation effectively addresses the computational bottleneck. Below, we address your questions point by point.

W1. Two of the three datasets (FANVID and RGB-NIR Scene) use synthetically constructed misalignment via 3D Gaussian splatting parallax simulation rather than real unaligned pairs. Only MS2 provides natural misalignment, raising concerns about how well results generalize to real-world dual-camera acquisition.

More real-world datasets. We conduct experiments on the RNS[1] dataset, which is a real-world dataset captured using an RGB-NIR dual-camera system. We use the original images without epipolar rectification, with RGB images from the right camera as targets and NIR images from the left camera as guidance. Within the limited rebuttal period, we evaluate representative methods on RNS, as shown in Table R1. UGD-FM achieves the best performance, demonstrating its generalizability to real-world data.

Clarification on 3DGS simulation. We note that our 3DGS simulation is geometry-aware, and produces realistic depth-dependent parallax and occlusion, as observed in real-world captures. Compared with the global 2D transformations used by 3M-TI[2], it better approximates real dual-camera acquisition. The consistent results on MS2 and RNS datasets further support the real-world applicability of UGD-FM.

Table R1. Comparison on the real-world RNS dataset under Poisson-Gaussian noise (alpha=0.03, sigma=0.3).

Method PSNR↑ SSIM↑ LPIPS↓
Restormer 28.20 0.7761 0.3793
RDBM (diffusion) 28.38 0.7678 0.3377
NAID 28.56 0.7997 0.3137
RFfusion (flow matching) 27.76 0.7626 0.3144
3M-TI (diffusion) 28.62 0.8011 0.3024
SGDFormer 28.39 0.7863 0.3307
UGD-FM (NAFNet, 1-step) 28.96 0.8110 0.2505
UGD-FM (NAFNet, 2-step) 29.10 0.8177 0.2280

W2. The paper lacks comparison with diffusion-based or flow-matching-based guided restoration methods. Baselines are limited to regression-based single-image and guided denoisers, making it unclear whether the gains stem from the flow matching paradigm or from the guidance aggregation design alone.

We compare UGD-FM with 3M-TI[2], RFfusion[3], and RDBM[4] on the FANVID and RNS datasets under Poisson-Gaussian noise (alpha=0.03, sigma=0.3). 3M-TI and RFfusion are cross-modal image restoration/fusion approaches based on diffusion and rectified flow, respectively. RDBM is a diffusion-based single image restoration method. As shown in Table R1 and Table R2, UGD-FM consistently achieves the best performance among the diffusion and flow matching based methods, demonstrating the effectiveness of our proposed components.

Table R2. Comparison on the FANVID dataset under Poisson-Gaussian noise (alpha=0.03, sigma=0.3).

Method PSNR↑ SSIM↑ LPIPS↓
RDBM (diffusion) 28.80 0.7828 0.3535
RFfusion (flow matching) 28.53 0.7702 0.3251
3M-TI (diffusion) 28.89 0.7872 0.3221
UGD-FM (NAFNet, 1-step) 30.12 0.8351 0.2351
UGD-FM (NAFNet, 2-step) 30.42 0.8458 0.2237
UGD-FM (Restormer, 1-step) 30.29 0.8401 0.2215
UGD-FM (Restormer, 2-step) 30.58 0.8506 0.2121

W3. Key hyperparameters (truncated Gaussian anchors τ_hc, τ_rc, σ_s, warm-up length N_warm, top-K value) are fixed without sensitivity analysis.

(1) anchor τ_hc. τ_hc represents the highly corrupted stage for few-step inference. As the flow-matching trajectory should begin at t=0 during inference, we set τ_hc=0 by default. As shown in Table R3, shifting it to 0.1 leads to a clear performance drop.

Table R3. Ablation on the time anchor τ_hc.

τ_hc 1-step PSNR 1-step SSIM 1-step LPIPS 2-step PSNR 2-step SSIM 2-step LPIPS
0 (default) 30.29 0.8401 0.2215 30.58 0.8506 0.2121
0.1 29.85 0.8266 0.2509 30.21 0.8391 0.2358

(2) anchor τ_rc. τ_rc indicates the relatively cleaner stage for few-step inference. We vary τ_rc from 0.3 to 0.9, and list the results in Table R4. An early anchor provides limited stage separation and thus smaller 2-step gains. When τ_rc establishes a clear boundary between the highly corrupted and relatively cleaner stages, 2-step inference yields clear performance gains, as observed at τ_rc=0.7 and τ_rc=0.9. Their comparable results also indicate that performance is not sensitive to the exact value of τ_rc.

Table R4. Ablation on the time anchor τ_rc.

τ_rc 1-step PSNR 1-step SSIM 1-step LPIPS 2-step PSNR 2-step SSIM 2-step LPIPS
0.3 30.34 0.8432 0.2235 30.39 0.8457 0.2216
0.5 30.33 0.8412 0.2192 30.49 0.8459 0.2191
0.7 30.33 0.8409 0.2237 30.56 0.8495 0.2133
0.9 (default) 30.29 0.8401 0.2215 30.58 0.8506 0.2121

(3) Standard deviation σ_s. σ_s controls the sampling concentration around time anchors. As shown in Table R5, similar results at 0.025 and 0.05 show that the method does not require careful tuning. However, an excessively large value like 0.2 disperses the training distribution away from the anchors and degrades performance.

Table R5. Ablation on σ_s.

σ_s 1-step PSNR 1-step SSIM 1-step LPIPS 2-step PSNR 2-step SSIM 2-step LPIPS
0.025 30.33 0.8414 0.2220 30.62 0.8524 0.2139
0.05 (default) 30.29 0.8401 0.2215 30.58 0.8506 0.2121
0.2 30.27 0.8384 0.2257 30.46 0.8453 0.2192

(4) Warm-up length N_warm. With a total training length of 80K iterations, we vary N_warm from 40K to 60K. As shown in Table R6, the performance remains stable, demonstrating that our method is robust to the warm-up length.

Table R6. Ablation on N_warm.

N_warm 1-step PSNR 1-step SSIM 1-step LPIPS 2-step PSNR 2-step SSIM 2-step LPIPS
40K 30.31 0.8406 0.2211 30.56 0.8512 0.2110
50K(default) 30.29 0.8401 0.2215 30.58 0.8506 0.2121
60K 30.29 0.8392 0.2224 30.55 0.8497 0.2123

(5) Top-K value. We vary K from 1 to 7, and list results in Table R7. A small K may discard plausible correspondences, causing a clear performance drop. Increasing K consistently improves performance. We use K=5 to balance accuracy and efficiency.

Table R7. Ablation on top-K value.

Top-K 1-step PSNR 1-step SSIM 1-step LPIPS 2-step PSNR 2-step SSIM 2-step LPIPS
1 29.89 0.8248 0.2449 30.19 0.8364 0.2345
3 30.26 0.8382 0.2264 30.55 0.8492 0.2159
5 (default) 30.29 0.8401 0.2215 30.58 0.8506 0.2121
7 30.30 0.8417 0.2185 30.59 0.8520 0.2110

W4. Scalability to high-resolution inputs and memory behavior under larger displacement ranges D are not discussed.

High-resolution inputs. We evaluate all methods at input resolutions 768*1024 on the RTX 4090 GPU. As shown in Table R8, UGD-FM achieves state-of-the-art performance without incurring prohibitive memory or inference-time overhead.

Table R8. Inference efficiency comparison at 768*1024.

Method Time(ms) Memory(GiB)
MPRNet 437 6.3
NAFNet 76 0.9
Uformer 171 4.7
Restormer 676 6.7
Xformer 1390 7.8
RDBM 3431 9.3
CUNet 162 1.9
DVN 159 3.9
RFFNet 164 11.4
NAID 120 1.5
SANet 194 4.4
RFfusion 841 20.7
3M-TI 654 9.7
UGD-FM(NAFNet,1-step) 250 5.1
UGD-FM(NAFNet,2-step) 487 5.1
UGD-FM(Uformer,1-step) 441 5.0
UGD-FM(Uformer,2-step) 829 5.0
UGD-FM(Restormer,1-step) 368 5.0
UGD-FM(Restormer,2-step) 694 5.0

Larger displacement ranges. We further increase D from 80 to 120 at input resolutions 768*1024. Table R9 shows that a larger range increases runtime due to additional correspondence search, while peak memory remains nearly unchanged. This is because sparse propagation retains only a fixed number of top-K candidates. Increasing D mainly increases coarse-search runtime, while the memory used by fine-scale propagation remains nearly constant.

Table R9. Inference efficiency under different search ranges D at 768*1024.

Backbone D 1-step time(ms) 1-step memory(GiB) 2-step time(ms) 2-step memory(GiB)
NAFNet 80 250 5.1 487 5.1
NAFNet 120 357 5.2 698 5.2
Restormer 80 368 5.0 694 5.0
Restormer 120 475 5.1 908 5.1
Uformer 80 441 5.0 829 5.0
Uformer 120 547 5.1 1040 5.1

Questions. Could the authors provide experiments on real-world unaligned RGB-NIR pairs (beyond MS2) and a sensitivity analysis for the key hyperparameters (τ_rc, σ_s, K)?

Real-world datasets. Please refer to W1.

Key hyperparameters. Please refer to W3.

Limitations. The method's reliance on synthetically simulated misalignment for two of three datasets and the unaddressed behavior under severe 3D parallax occlusion limit the demonstrated applicability to real-world deployment.

We clarify that the architecture and design of UGD-FM do not rely on simulated misalignment. The simulation is used to enable broader evaluation, and the strong results of UGD-FM on the real-world MS2 and RNS datasets demonstrate the applicability to real dual-camera acquisition (refer to W1). Although 3D parallax and occlusion are unavoidable, UGD-FM consistently achieves the best performance among the compared methods, demonstrating its contribution for unaligned image guided denoising.

References

[1] Pixel-aligned RGB-NIR Stereo Imaging and Dataset for Robot Vision. CVPR, 2025.

[2] 3M-TI: High-Quality Mobile Thermal Imaging via Calibration-free Multi-Camera Cross-Modal Diffusion. CVPR, 2026.

[3] Efficient Rectified Flow for Image Fusion. NeurIPS, 2025.

[4] Residual Diffusion Bridge Model for Image Restoration. CVPR, 2026.

Comments on the paper

1 comment
Area Chair ohEv · CommentOpenReview ↗

After rebuttal discussion

Dear reviewers,

The authors have responded to the reviews. Please check the rebuttal to see whether your concerns have been addressed, and raise any remaining questions to the authors if necessary. Please note that the final rating should be submitted before August 10.

Best

AC

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Missing a submission?

Loading the discussion…