GradTrack: Detecting Noisy Labels via Temporal Trajectories of Class-wise Gradient Misalignment
Townim Faisal Chowdhury, Ta Duc Huy, Vu Minh Hieu Phan, Anton van den Hengel, Johan W. Verjans, Gustavo Carneiro, Zhibin Liao
NeurIPS 2026
Abstract. Noisy-label detection aims to identify incorrectly labeled training samples so that their adverse impact on model learning can be mitigated. Existing methods typically rely on loss, prediction confidence, or gradient magnitude signals, which primarily capture the scale of prediction errors. While effective, such scalar signals overlook the geometric structure and temporal dynamics of gradient evolution during training. In this work, we show that gradient magnitude provides a useful entry point for analysing the gradient distortion induced by noisy-label samples, enabling us to quantify their deviation from the gradients that would be generated by clean labels. In this light, we propose GradTrack, a simple and effective framework for detecting noisy-label samples by estimating class-wise gradient directions likely to be induced by clean labels and measuring the alignment of training samples with these directions. In each training epoch, GradTrack partitions samples based on gradient magnitude and approximate clean-label gradient directions to compute a class-wise gradient misalignment score. These scores are used to rank training samples, which are then aggregated across training epochs to form a temporal rank trajectory. Finally, a Gaussian mixture model is applied to detect noisy-label samples. Extensive experiments on both synthetic and real-world noisy-label benchmarks demonstrate that GradTrack achieves strong detection performance, particularly under instance-dependent noise, and can further improve existing learning-with-noisy-labels pipelines as a plug-in sample selection module. Our code is publicly available at https://github.com/AIML-MED/GradTrack.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:49 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
The paper introduces GradTrack, a gradient‑dynamics–based framework for noisy‑label detection. The method estimates class‑wise clean‑label gradient directions from low‑ and medium‑magnitude samples, computes per‑sample gradient misalignment scores, and aggregates these signals across training epochs using temporal rank trajectories and a GMM. The idea is intuitive and the empirical results are strong on several synthetic and real‑world benchmarks, particularly under instance‑dependent noise. The method is simple to integrate into existing LNL pipelines and shows consistent improvements in high‑noise regimes.
However, the reviewers have identified several substantial concerns that limit the contribution. The conceptual foundation relies heavily on three empirical observations demonstrated only on a single dataset, encoder, and noise type, without statistical validation or evidence that the gradient‑alignment patterns generalize across architectures, datasets, or training dynamics. These observations are treated as universal properties of noisy‑label learning, but the paper provides no justification for this assumption. Furthermore, it seems that the core design choice contradicts the paper's own Observation 2. In particular, the analysis from Fig 2 concludes that low-magnitude gradients are the least informative for estimating the true clean direction, and that the medium-magnitude group is the best approximator. Nevertheless, the proposed method anchors using bottom-K (i.e., lowest magnitude) in Eq 2 (note that the entire misalignment score and downstream detection depend on ). In addition, the pipeline itself is complex and involves multiple interacting components (gradient partitioning, class‑wise bottom‑K selection, SVD denoising, temporal rank modeling, GMM), which incurs higher complexity times, yet the paper provides no analysis about this. How these components interact, whether they are stable across training conditions, or under what regimes they may fail remains also unexplored. This makes it difficult to assess the robustness of the overall approach.
In terms of empirical vallidation, the evaluation is restricted to a frozen CLIP encoder, whose gradient dynamics may differ significantly from standard CNNs or ViTs (not trained in a contrastive manner), making unclear whether the proposed approach remains effective in more conventional settings or other architectures (even in the current validation only one backbone is used along all experiments). Moreover, an important concern raised is that the method performs poorly in realistic low‑noise regimes (e.g., CIFAR‑10N Agg), suggesting over‑cleansing and lack of calibration, but the paper does not analyze this failure mode. Finally, and related to the higher complexity times concern, the scalability of the approach (which requires per‑sample gradient tracking across epochs and repeated SVD computations) is not discussed, which might not be scalable or practical for real‑world settings.
Final justification
This submission received an overall positive feedback from the reviewers, with three borderline accepts. In addition to reviewers comments, this AC went through the initial reviews and raised additional concerns, which were mostly addressed by the authors during the rebuttal/discussion process. Given the new evidence, clarifications and responses from authors, I recommend the acceptance of this work, and strongly encourage the authors to include their responses into the final manuscript, which will further improve this work.
Read meta-review
Meta-review
The paper introduces GradTrack, a gradient‑dynamics–based framework for noisy‑label detection. The method estimates class‑wise clean‑label gradient directions from low‑ and medium‑magnitude samples, computes per‑sample gradient misalignment scores, and aggregates these signals across training epochs using temporal rank trajectories and a GMM. The idea is intuitive and the empirical results are strong on several synthetic and real‑world benchmarks, particularly under instance‑dependent noise. The method is simple to integrate into existing LNL pipelines and shows consistent improvements in high‑noise regimes.
However, the reviewers have identified several substantial concerns that limit the contribution. The conceptual foundation relies heavily on three empirical observations demonstrated only on a single dataset, encoder, and noise type, without statistical validation or evidence that the gradient‑alignment patterns generalize across architectures, datasets, or training dynamics. These observations are treated as universal properties of noisy‑label learning, but the paper provides no justification for this assumption. Furthermore, it seems that the core design choice contradicts the paper's own Observation 2. In particular, the analysis from Fig 2 concludes that low-magnitude gradients are the least informative for estimating the true clean direction, and that the medium-magnitude group is the best approximator. Nevertheless, the proposed method anchors using bottom-K (i.e., lowest magnitude) in Eq 2 (note that the entire misalignment score and downstream detection depend on ). In addition, the pipeline itself is complex and involves multiple interacting components (gradient partitioning, class‑wise bottom‑K selection, SVD denoising, temporal rank modeling, GMM), which incurs higher complexity times, yet the paper provides no analysis about this. How these components interact, whether they are stable across training conditions, or under what regimes they may fail remains also unexplored. This makes it difficult to assess the robustness of the overall approach.
In terms of empirical vallidation, the evaluation is restricted to a frozen CLIP encoder, whose gradient dynamics may differ significantly from standard CNNs or ViTs (not trained in a contrastive manner), making unclear whether the proposed approach remains effective in more conventional settings or other architectures (even in the current validation only one backbone is used along all experiments). Moreover, an important concern raised is that the method performs poorly in realistic low‑noise regimes (e.g., CIFAR‑10N Agg), suggesting over‑cleansing and lack of calibration, but the paper does not analyze this failure mode. Finally, and related to the higher complexity times concern, the scalability of the approach (which requires per‑sample gradient tracking across epochs and repeated SVD computations) is not discussed, which might not be scalable or practical for real‑world settings.
Final justification
This submission received an overall positive feedback from the reviewers, with three borderline accepts. In addition to reviewers comments, this AC went through the initial reviews and raised additional concerns, which were mostly addressed by the authors during the rebuttal/discussion process. Given the new evidence, clarifications and responses from authors, I recommend the acceptance of this work, and strongly encourage the authors to include their responses into the final manuscript, which will further improve this work.
1 comment
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 2/4
- Significance
- 2/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This work presents a novel noisy-label selection scheme depending on gradient magnitude and its directions. For 11 noisy-label detection settings, GradTrack achieves the highest average performance. The authors integrate this approach with several existing LNL baselines, and it is shown that GradTrack enhances performance in CIFAR-100N, WebVision, and Clothing1M datasets.
Strengths and weaknesses
The paper demonstrates clear performance gains over existing algorithms. In particular, it shows that the proposed method outperforms prior approaches under various noisy-label settings, which supports the effectiveness of the method in learning with noisy labels.
While the proposed method demonstrates a significant performance gain under severe noise conditions (e.g., CIFAR-10N-Worst with ~40% noise rate), its accuracy drops to 70% in a low noise regime (e.g., CIAFAR-10N-Agg with ~9% noise rate). I attribute this degradation to the over-cleansing effect. That is, the algorithm mistakenly filters out hard-yet-clean samples as noise, leading to a reduction in the performance. There is a lack of analysis on these aspects.
Questions
- Although the proposed method achieves strong results under synthetic noisy-label settings, its performance on CIFAR-10N (Agg. 0.09), a real-world human-annotated noisy-label benchmark, is significantly lower than that of competing methods. Could the authors clarify why the method generalizes well to synthetic noise but struggles under real-world label noise?
- In Table 1, the results are presented for different types of label noise. However, it remains unclear whether the proposed method becomes more or less effective as the noise ratio increases or decreases under the same noise setting. Could the authors provide additional analysis or comparisons to show how the relative performance gain of the proposed method changes with changing noise ratios within the same dataset and noise type?
- The authors are dividing samples into three groups (low, mid, high) based on gradient magnitudes. Could the authors clarify whether this grouping rule is robust to different noise ratios?
Limitations
- A limitation is that group partitioning based on gradient magnitude may be sensitive to variations in noise ratio, potentially leading to performance degradation. It needs analysis on these aspects.
Formatting concerns
Overall, the paper is readable, but the tables and figures could be made more consistent.
2 comments
Rebuttal
We sincerely thank Reviewer RE1F (R3) for the thoughtful, constructive, and detailed feedback. We address R3’s specific comments below and welcome any further discussion.
R3-Q1. "Over-cleansing" at low noise rates.
We agree with R3 that the performance drop on CIFAR-10N-Agg is a result of over-cleansing. In this setting, the underlying ranking of noise samples is excellent (AUC ) and with a high recall (), but a low precision (). Across the other 10 settings, recall stays similarly high (, range –), while precision averages much higher (). So GradTrack catches nearly all noisy samples, but at the cost of also flagging many clean ones, i.e. over-cleansing. On CIFAR-10N Agg., the confusion matrix is:
Table R3.1
| Predicted Noisy | Predicted Clean | |
|---|---|---|
| Actual Noisy | 4,181 (TP) | 324 (FN) |
| Actual Clean | 3,392 (FP) | 42,103 (TN) |
Here the GradTrack outcome’s effective predicted noise rate is 15.14%, which harms the overall performance because CIFAR-10N Agg. has the lowest base noise rate 9.01%.
Appendix A.3/Fig. 7 shows that raising explained-variance threshold from to already recovers F1 to and an effective predicted noise rate of 9.73%, so this is a threshold-calibration issue at low noise rates, not a failure of the underlying signal. This suggests that the intrinsic problem here is that GradTrack is noise rate agnostic; a design choice we made to make GradTrack generic by not assuming knowledge of the noise rate. We will add this precision/recall and over-cleansing analysis in Appendix A.3 to explain this failure mode more clearly in the revised paper.
R3-Q2. Synthetic vs. real-world noise.
GradTrack performs well on the other two real-world noise settings (CIFAR-10N Worst 0.4: ; CIFAR-100N Human 0.4: ), and its underperformance on CIFAR-10N Agg. 0.09 is the same over-cleansing/threshold-calibration issue discussed above, not a general weakness on real-world noise.
From a performance comparison point of view, GradTrack (69.23) trails CORES (80.50) [ref 3-1] and SIMIFEAT-R (79.16) [ref 3-2] on CIFAR-10N Agg. 0.09, so we further analyze why these methods perform better in this specific low-noise setting. SIMIFEAT-R’s per-class noise-transition estimate appears well matched to this low-noise case, but this advantage does not hold uniformly across settings: GradTrack has higher average F1 across all 11 settings (87.40 vs. 83.02). CORES shows a similar sensitivity to thresholding; it performs well on CIFAR-10N Agg. but has much lower average F1 across all settings (61.58). In contrast, GradTrack’s GMM estimator does not assume a known noise rate, which improves robustness across settings but can be less calibrated in very low-noise regimes. Given that real-world noise rates can vary substantially across domains, e.g., in medical image grading tasks, the inter-observer inconsistencies (noises) can be as large as 65% [ref 3-3], specific tuning a method toward high or low noise ratios may not be a good strategy. A practical consideration to determine the noise ratio can be randomly relabelling a small proportion of the dataset and then tuning GradTrack (or any other noisy sample detection methods) parameters toward those, but this is orthogonal to the main objectives of GradTrack; hence, we will discuss this in the revised paper.
R3-Q3. Varying noise ratio.
The requested noise-ratio analysis is shown in Fig. 5, for instance-dependent noise with noise rate – on three datasets: CIFAR-10/100/Tiny-ImageNet. GradTrack consistently outperforms SIMIFEAT-V [ref 3-2] across the sampled noise rates and remains competitive at low noise levels on CIFAR-10, indicating stronger robustness to varying noise severity. On the other hand, the concave shape of the noise ratio analysis in terms of performance suggests that both GradTrack and SIMIFEAT-V, the top-performing methods, handle 30-40% noise ratios the best.
R3-Q4. Robustness of the low/mid/high grouping to noise ratio.
Thank you for the suggestion. We have run the requested noise ratio vs three groups and will add it to the appendix: for CIFAR-10, CIFAR-100, and Tiny-ImageNet under instance-dependent noise at , we compare the three partition ratios from Appendix A.4 (20-60-20, 25-50-25, 33-33-33):
Table R3.2
| Setting | 20-60-20 | 25-50-25 | 33-33-33 | mean std | |
|---|---|---|---|---|---|
| CIFAR-10 Inst. | 0.1 | 87.62 | 88.09 | 88.20 | 87.97 (±0.31) |
| CIFAR-10 Inst. | 0.2 | 91.36 | 91.24 | 91.30 | 91.30 (±0.06) |
| CIFAR-10 Inst. | 0.3 | 94.23 | 94.23 | 94.22 | 94.23 (±0.01) |
| CIFAR-10 Inst. | 0.4 | 94.78 | 94.79 | 94.80 | 94.79 (±0.01) |
| CIFAR-10 Inst. | 0.5 | 85.58 | 85.56 | 85.56 | 85.57 (±0.01) |
| CIFAR-100 Inst. | 0.1 | 83.00 | 81.96 | 83.05 | 82.67 (±0.62) |
| CIFAR-100 Inst. | 0.2 | 87.55 | 86.64 | 86.03 | 86.74 (±0.76) |
| CIFAR-100 Inst. | 0.3 | 85.31 | 85.04 | 86.98 | 85.78 (±1.05) |
| CIFAR-100 Inst. | 0.4 | 89.41 | 89.31 | 89.25 | 89.32 (±0.08) |
| CIFAR-100 Inst. | 0.5 | 83.51 | 83.60 | 83.60 | 83.57 (±0.05) |
| Tiny-ImageNet Inst. | 0.1 | 72.46 | 72.53 | 73.49 | 72.83 (±0.58) |
| Tiny-ImageNet Inst. | 0.2 | 78.62 | 78.47 | 80.07 | 79.05 (±0.88) |
| Tiny-ImageNet Inst. | 0.3 | 81.31 | 82.29 | 83.22 | 82.27 (±0.96) |
| Tiny-ImageNet Inst. | 0.4 | 86.45 | 86.38 | 86.32 | 86.38 (±0.07) |
| Tiny-ImageNet Inst. | 0.5 | 79.36 | 79.44 | 80.10 | 79.63 (±0.41) |
Across all 15 dataset and combinations, the std across the three partition ratios is at most ±1.05, indicating the grouping partition is insensitive to the noise ratio change.
References
[ref 3-1] Cheng, Hao, et al. "Learning with instance-dependent label noise: A sample sieve approach." arXiv preprint arXiv:2010.02347, 2020.
[ref 3-2] Zhu, Zhaowei, et al. "Detecting corrupted labels without training a model to predict." ICML, 2022.
[ref 3-3] Chokuwa, Sharon, et al. "Divergent Domains, Convergent Grading: Enhancing Generalization in Diabetic Retinopathy Grading." WACV 2025.
Thank you very much for your time and positive evaluation of our work. We truly appreciate your thoughtful review and constructive feedback, which have helped us significantly improve the quality and presentation of our paper. We hope that our rebuttal has successfully resolved your concerns.
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 4/4
- Clarity
- 4/4
- Significance
- 3/4
- Originality
- 4/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper proposes GradTrack, a simple and effective framework for noisy-label detection. It estimates class-level gradient directions from potentially clean samples and identifies noisy samples based on gradient alignment. The paper also provides useful empirical observations for future research.
Strengths and weaknesses
Strengths
- The paper is clearly written, and the main claims are well supported by the experiments.
- The empirical observations are insightful, and it is encouraging to see that the proposed method is directly motivated by these observations.
- The paper addresses several limitations of previous methods based on loss values, prediction confidence, or gradient magnitude alone.
- The proposed method is simple yet effective and achieves strong empirical results.
Weaknesses
-
The experimental results suggest that the proposed method is effective in addressing the main problem. The existing ablation indicates that class-wise misalignment is the primary contributor, while gradient magnitude provides an additional improvement. However, a more detailed analysis of how gradient magnitude and the denoised class-wise misalignment score provide complementary signals across different training epochs, and whether any consistent pattern can be observed would further strengthen the claim of complementarity.
-
For significance, the experimental evaluation is mainly setting with frozen CLIP encoder. Results with additional backbones or feature encoders would be valuable.
Questions
- What different types of information are captured by gradient magnitude and the denoised class-wise misalignment score? Do these two signals exhibit consistent patterns across different training epochs?
- Since both signals are used in the final noisy-label detection criterion, what is the individual contribution of each signal to the final score? Whether any general pattern can be observed?
- How does it perform with encoders other than the frozen CLIP? Do the performance gains and the observed patterns remain consistent?
Limitations
Yes
Final justification
Overall, while the method achieves strong results in some settings, I would have expected a more in-depth analysis of its limitations and its feasibility in real-world applications. Thus, I will keep my original score.
Formatting concerns
No
3 comments
Rebuttal
We sincerely thank Reviewer hgdm (R2) for the thoughtful, constructive, and detailed feedback. We address R2’s comments below and welcome any further discussion.
R2-Q1. Complementarity between gradient magnitude and the class-wise misalignment score.
Gradient magnitude measures how strong a sample's gradient is and is strongly correlated with the loss error magnitude underpinned by the chain rule. It is a per-sample measurement.
The misalignment score captures additional information that is measured for each sample with respect to the estimated clean-label direction from training samples in the same semantic class, whereas the estimated clean-label direction brings in the additional population-level (i.e., the cohort of ) information that an individual sample cannot estimate.
To empirically measure their differences, following the same setting as Figure 3, we computed the Spearman rank correlation (value ranges between -1 and 1, higher indicates more positively correlated) between the per-sample magnitude ranking and the per-sample misalignment ranking, averaged over post-warm-up epochs: ρ = 0.532 ± 0.045, suggesting they are moderately correlated, hence share noise-detecting characteristics but do not significantly mimic each other. The low std shows this moderate correlation relationship holds steadily across training.
Based on this result, together with the strong individual performance of both measures on the label noise detection task (please refer to R2-Q2 below), we demonstrate that the gradient magnitude and the class-wise misalignment score provide complementary cues for detecting noisy labels.
R2-Q2. Individual contribution of gradient magnitude and the denoised class-wise misalignment score.
Please refer to Table 3 / Fig. 4: "Magnitude-Only" uses only gradient magnitude and reaches 71.30% average F1 across the 11 benchmark settings; "" uses the denoised score and reaches 85.55%; combining both reaches 87.40%. So empirically we can conclude the misalignment score provides a relatively stronger performance improvement than the gradient magnitude. Table 3's per-setting results show this gain is consistent across all 11 settings.
R2-Q3. Additional encoders.
To test whether GradTrack's advantage holds beyond CLIP features, we run GradTrack and the strongest Table 1 baseline, SimiFeat-V [ref 2-1], with a different frozen encoder, ResNet-50 (pretrained on ImageNet, standard CNN), across all 11 benchmark settings, which verifies that GradTrack maintains the leading performance on the standard CNN backbones as well. Please see Table R2.1 below.
Table R2.1
| Setting | SimiFeat-V | GradTrack |
|---|---|---|
| CIFAR-10 Sym. 0.6 | 93.28 | 96.27 |
| CIFAR-10 Asym. 0.3 | 65.94 | 42.29 |
| CIFAR-10 Inst. 0.4 | 82.37 | 94.22 |
| CIFAR-10N Worst 0.4 | 87.14 | 88.43 |
| CIFAR-10N Agg. 0.09 | 66.94 | 39.99 |
| CIFAR-100 Sym. 0.6 | 86.11 | 94.52 |
| CIFAR-100 Asym. 0.3 | 68.19 | 78.36 |
| CIFAR-100 Inst. 0.4 | 76.70 | 91.67 |
| CIFAR-100N Human 0.4 | 75.25 | 73.60 |
| Tiny-ImageNet Sym. 0.6 | 76.60 | 94.33 |
| Tiny-ImageNet Inst. 0.4 | 76.72 | 86.96 |
| Average F1 (%) | 77.75 | 80.06 |
References
[2-1] Zhu, Zhaowei, et al. "Detecting corrupted labels without training a model to predict." ICML, 2022.
Thank you for your response. It has addressed most of my questions. I did notice that with ResNet-50, some results (e.g., CIFAR-10N Agg. 0.09 and CIFAR-10 Asym. 0.3) show a large gap from SimiFeat-V. If possible, I would like to know whether you have any further analysis on why this occurs.
Thank you for the follow-up, and apologies for the delayed response. We conducted additional experiments and found that the primary source of the performance gap is the training duration. In our previous experiments, we adopted the same 30-epoch training schedule used for CLIP on CIFAR-10 settings. However, our further investigation showed that the ResNet-50 model had not yet converged after 30 epochs, leading to the observed performance gap. We therefore retrained the CIFAR-10 model for 50 epochs to be consistent with the other experimental settings. The updated results are presented in Table R2.2. For completeness, we also include the CIFAR-100 and Tiny-ImageNet results, which remain unchanged from Table R2.1 in our last reply.
For CIFAR-10 Asym. 0.3, the GradTrack performance (63.99) is now comparable with SimiFeat-V (65.94).
For CIFAR-10N Agg. 0.09, although the performance improved, the gap between SIMIFeat-V and GradTrack remains large. Our analysis indicates that this arises from the same over-cleansing failure mode discussed in R3-Q1. Specifically, GradTrack achieves an AUC of 96.38% and a recall of 96.98%, but its precision drops to only 27.66%, corresponding to an effective predicted noise rate of 31.59% (compared with 15.14% for the CLIP-based model), substantially higher than the true noise rate of 9.01%.
Table R2.2
| Setting | SimiFeat-V | GradTrack (CIFAR-10 30 epochs, rest 50 epochs) | GradTrack (All 50 epochs) |
|---|---|---|---|
| CIFAR-10 Sym. 0.6 | 93.28 | 96.27 | 96.53 |
| CIFAR-10 Asym. 0.3 | 65.94 | 42.29 | 63.99 |
| CIFAR-10 Inst. 0.4 | 82.37 | 94.22 | 94.50 |
| CIFAR-10N Worst 0.4 | 87.14 | 88.43 | 88.64 |
| CIFAR-10N Agg. 0.09 | 66.94 | 39.99 | 43.05 |
| CIFAR-100 Sym. 0.6 | 86.11 | 94.52 | 94.52 |
| CIFAR-100 Asym. 0.3 | 68.19 | 78.36 | 78.36 |
| CIFAR-100 Inst. 0.4 | 76.70 | 91.67 | 91.67 |
| CIFAR-100N Human 0.4 | 75.25 | 73.60 | 73.60 |
| Tiny-ImageNet Sym. 0.6 | 76.60 | 94.33 | 94.33 |
| Tiny-ImageNet Inst. 0.4 | 76.72 | 86.96 | 86.96 |
| Average F1 (%) | 77.75 | 80.06 | 82.38 |
We believe the performance difference between the CLIP- and ResNet-50-based models arises from differences in their pretraining. CLIP was pretrained on a substantially larger and diverse corpus, whereas ResNet-50 was pretrained only on ImageNet. ResNet-50 requires a longer training period to converge on CIFAR-10. One possible explanation is that CLIP's large-scale pretraining produces latent representations that are more transferable to the downstream task, allowing the model to converge more rapidly during fine-tuning. At the CIFAR-10N Agg. 0.09 low-noise setting, the slower convergence amplifies the threshold-sensitivity issue, resulting in the over-cleansing behaviour observed above. We will discuss those aspects of the model differences in the revised paper.
- Rating
- 4/6
- Confidence
- 2/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 2/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
Noisy-label detection technique is an important pre-step for noisy-label learning. The proposed GradTrack aims to improve existing noisy-label learning pipelines as a plug-in sample selection module. It is applied by estimating class-wise gradient directions likely to be induced by clean labels and measuring the alignment of training samples with these directions.
Strengths and weaknesses
Strengths: Evaluated on 11 synthetic and real-world noisy-label benchmarks, GradTrack achieves strong detection performance, particularly under instance-dependent noise, and can serve as a plug-in sample selection module for existing learning-with-noisy-labels pipelines. Weaknesses: GradTrack partitions samples based on gradient magnitude and approximate clean-label gradient directions to compute a class-wise gradient misalignment score. However, these proposed menthods are based on the motivation from the observation 1-3 in the paper. In my opinion, the observation may not be sufficient to support the ideas in these proposed menthods, while the authors can give statistical data, rather than limited figures or observations, to show the effectiveness of the motivation.
Questions
Could the authors can address the following concerns?
GradTrack partitions samples based on gradient magnitude and approximate clean-label gradient directions to compute a class-wise gradient misalignment score. However, these proposed menthods are based on the motivation from the observation 1-3 in the paper. In my opinion, the observation may not be sufficient to support the ideas in these proposed menthods, while the authors can give statistical data, rather than limited figures or observations, to show the effectiveness of the motivation.
Limitations
The work has the following limitation, and it will be more solid if this can be addressed.
A two-component Gaussian mixture model is applied to detect noisy label samples. The GMM is with full covariance to the embeddings. As the mixture components areunlabeled, the authors identify the component with the higher average rank as corresponding to noisy-label samples. The posterior probability method produced with two-component GMM may be too simple, and may infulence the final results. The authors can try other more complicated and effective methods.
Final justification
The authors addressed my concern.
Formatting concerns
N/A
2 comments
Rebuttal
We sincerely thank Reviewer 1GU4 (R1) for the thoughtful, constructive, and detailed feedback. We address R1’s specific comments below and welcome any further discussion.
R1-Q1. On statistical analysis of Observations 1–3.
We agree with R1 that statistical data on how those observations play out across all 11 benchmark settings is important and report them in Table R1.1 below.
Table R1.1
| Observation | Statistics (mean ± std, All 11 settings) | Statistics (mean ± std, exception settings) |
|---|---|---|
| Obs. 1: gradient magnitude stratifies clean/noisy samples | % of noisy samples: Low 2.35 (±2.76); Medium 36.54 (±27.58); High 79.35 (±22.90) | None (supported in all 11 settings) |
| Obs. 2: medium-magnitude group best approximates the clean-label direction | cos(avg-gradient, TRUE clean-label gradient direction): 1) Low-magnitude group: 0.59 (±0.23); 2) Medium-magnitude group: 0.60 (±0.26); 3) High-magnitude group: 0.13 (±0.32). | 3 exception settings (symmetric ): 1) Low-magnitude group: 0.87 (±0.09); 2) Medium-magnitude group: 0.28 (±0.32); 3) High-magnitude group: 0.01 (±0.40). |
| Obs. 3: gradient magnitude alone cannot separate hard-clean from noisy samples | Overlap coefficient (OVL, lower is better): 1) Gradient Magnitude: 0.37 (±0.19); 2) Class-wise grad. misalignment: 0.25 (±0.15); 3) Denoised class-wise grad. misalignment: 0.24 (±0.15) | 4 exceptional settings: 1) Gradient Magnitude: 0.23 (±0.15); 2) Class-wise grad. misalignment: 0.40 (±0.17); 3) Denoised class-wise grad. misalignment: 0.37 (±0.17) |
To summarize, the additional statistics suggest that the observations derived from the CIFAR-100 Inst. 0.4 setting are empirically consistent across the 11 evaluated settings. We also report and discuss several exceptions below.
Observation 1. Observation 1 is supported in all 11 settings. Therefore, the statement of Observation 1 will remain unchanged.
Observation 2. Observation 2 is supported in 8 of the 11 settings, where the Medium group achieves the highest cosine similarity. The exceptions occur in the three Symmetric noise () settings. Our further investigation indicates that the Medium group in these settings is itself highly contaminated by noisy samples (76.6–79.9% noisy, compared with 22.6–35.1% in the remaining settings). Consequently, the noisy samples distort the average gradient direction computed from the medium-magnitude group, leading to weaker alignment with the true clean-label gradient direction. To better reflect the empirical findings across all 11 settings, we will revise Observation 2 as follows:
"Both low- and medium-magnitude groups may provide a reasonable approximation of the clean-label gradient direction."
Observation 3. Observation 3 is supported in 7 of the 11 settings, where the OVL of the misalignment score is lower than that of the gradient magnitude. The exceptions are CIFAR-10 Asym. 0.3, CIFAR-10N Worst 0.4, CIFAR-10N Agg. 0.09, and CIFAR-100N Human 0.4, spanning different noise types and noise rates. We would like to emphasize that the purpose of Observation 3, as stated in the paper, is:
"This highlights the need for additional signals beyond gradient magnitude to effectively detect noisy-label samples."
We agree that comparing OVLs between gradient magnitude and gradient misalignment is not the clearest way to support this conclusion. Following Reviewer hgdm (R2)'s suggestion regarding the complementarity of the two signals, we instead plan to quantify their relationship using Spearman's rank correlation (please refer to our response entitled "Complementarity between gradient magnitude and the class-wise misalignment score" to R2). Accordingly, Observation 3 will be revised to:
"Gradient magnitude and gradient misalignment provide complementary information for distinguishing hard-clean samples from noisy samples."
Importantly, these revisions affect only the wording of the observations. They do not alter the underlying methodology or the paper's contribution claims; rather, they make the observations more accurately reflect the empirical evidence across the 11 evaluated settings. We appreciate Reviewer R1's suggestion, which has strengthened the paper and helped us present our findings more accurately.
R1-Q2. On the two-component GMM as the final detection step.
The GMM is a simple choice, but two points support it. 2-component mixtures over a low-dimensional per-sample signal are standard for clean/noisy separation (e.g., DivideMix [ref 1-1] fits one on per-sample loss); ours instead operates on the SVD-denoised rank-trajectory embedding (Eq. 7), which already aggregates magnitude and misalignment ranks across all post-warm-up epochs, so most separation work happens upstream (Secs. 4.2, 4.4) and the GMM only clusters an already well-separated signal. Our sensitivity analyses (Appendix A.2–A.5) also show stable performance across hyperparameters and temporal-aggregation choices, so the pipeline, including this step, is robust.
That said, we agree a direct comparison against alternative posterior-estimation methods would strengthen this design choice, so we ran the proposed 2-component GMM (applied to our post-warm-up rank trajectory) against (i) K-means clustering, and (ii) HDBSCAN [ref 1-2], a sophisticated density-based clustering method that does not require a fixed number of clusters, on the same embedding, across all 11 settings:
Table R1.2
| Method | GMM, K=2 | K-means | HDBSCAN |
|---|---|---|---|
| Average F1 (%) | 87.40 (±8.16) | 81.26 (±18.45) | 59.48 (±18.01) |
The proposed design (2-component GMM on the post-warm-up rank trajectory) achieves the best average F1 (87.40%, std 8.16), followed by K-means (81.26%, std 18.45), with HDBSCAN clearly worst and least stable (59.48%, std 18.01). HDBSCAN underperforms because it often splits the data into more than 2 clusters (4 of 11 settings) and leaves a large share of samples uncluttered as outliers, which we treat as clean by default and which inflates false negatives. All three methods cluster the same small, already-computed rank trajectory rather than raw gradients, so their cost is negligible next to the pipeline's dominant gradient-extraction step; on a representative setting (CIFAR-10 Instance , =50k), GMM and K-means fit in a comparable ≈1.0-1.2s, while HDBSCAN's neighbor search is about 20x slower (≈23s). Overall, these results support keeping the 2-component GMM as the final step.
References
[ref 1-1] Li, Junnan, et al. "Dividemix: Learning with noisy labels as semi-supervised learning." ICLR, 2020.
[ref 1-2] McInnes, Leland, et al. "HDBSCAN: Hierarchical density based clustering." J. Open Source Softw. 2.11 (2017): 205.
Thank you very much for your time and positive evaluation of our work. We truly appreciate your thoughtful review and constructive feedback, which have helped us significantly improve the quality and presentation of our paper. We hope that our rebuttal has successfully resolved your concerns.
Comments on the paper
1 comment
Rebuttal discussion
Dear reviewers,
As we move toward the end of the discussion period for the authors, I kindly ask each of you to review the authors’ rebuttal and provide an updated assessment. Some of the raised concerns may now be resolved, while others might still require clarification.
To support a clear and constructive meta‑review, please indicate:
-
Which concerns you consider fully addressed.
-
Which remain unresolved or insufficiently answered.
-
Any new issues, if any, introduced by the rebuttal.
Your timely feedback will help ensure consistency and fairness in the evaluation.
Thanks, your AC.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
We sincerely thank the Area Chair (AC) for the thoughtful, constructive, and detailed feedback. Several of the AC concerns have been addressed in our responses to Reviewers 1GU4 (R1), hgdm (R2), and RE1F (R3) below:
We address the remaining AC-raised points below and welcome further discussions.
AC-Q2. Clarification regarding the “contradiction” between Fig. 2, Observation 2, and Eq. 2.
We clarify that Observation 2 does not imply using the medium-magnitude group alone. Fig. 2(b) shows that the high-magnitude group is least aligned with the clean-label gradient, while the low- and medium-magnitude groups both contain useful clean-gradient signal. The word “best” referred to the medium group having the highest cosine similarity in Fig. 2(b), but the method uses this to motivate including medium-magnitude samples in addition to low-magnitude samples. Specifically, Eq. 2 selects the class-wise bottom-K anchor from Sl+me, which contains both low- and medium-magnitude groups (L170), rather than from the global low group alone. We will revise Observation 2 as described in R1-Q1.
AC-Q3. Pipeline component interaction and stability.
Sec. 5.4, Fig. 4, and Appendix Table 3 ablate the pipeline progressively: magnitude only, class-wise misalignment without SVD, SVD with all gradients, SVD with Sl+me, and the full trajectory. Table AC.1 maps the AC-requested components to the relevant existing or new analyses, including gradient partitioning, bottom-K sensitivity, SVD denoising, temporal rank modeling, and the GMM ablation in R1-Q2.
Table AC.1Table AC.2AC-Q6. Scalability.
We profiled GradTrack's compute cost on Tiny-ImageNet (instance-dependent noise, η=0.4; 200 classes, 100k training images, 50 epochs) - the most computationally heavy setting:
Per-sample gradient extraction dominates runtime (98.97%). All GradTrack-specific steps together add only 112.5s, or 1.03% of total wall-clock time. Thus, the main cost comes from per-sample gradient extraction, which is common to gradient-based detection methods such as TracIn [34]. We will add this profiling table to the paper.