potentialpaper

Anatomy-Activated Mixture-of-Experts for 3D Medical Vision-Language Pre-training

Szymon Plotka, Gizem Mert, Pedro R. A. S. Bassi, Wenxuan Li, Zongwei Zhou, Anna M Marcinkiewicz, Wiktoria Romańczyk, Jarosław B. Ćwikła, Łukasz Struski, Ewa Szczurek, Jacek Tabor, Arkadiusz Sitek

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

Abstract. Medical Vision-Language Pre-training (VLP) leverages the semantic richness of radiology reports to learn 3D representations, yet current architectures remain fundamentally anatomy-agnostic. While clinical diagnostics rely on organ-specific context, standard encoders apply a uniform, dense parameterization to all volumetric patches, and existing Mixture-of-Experts (MoE) routers gate on isolated local features without explicit access to the organ composition of the scan or crop. We propose Anatomy-Activated Mixture-of-Experts (A$^{2}MoE),aframeworkthatincorporatesanatomicalinductivebiaseswithinthemodel′scomputationalpath.AMoE), a framework that incorporates anatomical inductive biases within the model's computational path. A^{2}$MoE introduces two key components: (1) a Histogram Representation Router (HRR) that conditions expert selection on global visual context and a predicted anatomical composition histogram, encouraging anatomy-dependent expert weighting; and (2) an Organ-Query Multi-Scale Projector (OQMSP) that utilizes learnable queries to extract organ-level embeddings for fine-grained alignment without requiring manual annotations at inference. By routing at the patch level rather than the token level, A$^{2}MoEreducesroutingcomplexitybyordersofmagnitudewhilesatisfyingloadbalancingbyconstruction.Pre−trainedonover60,000multi−phaseCTscans,AMoE reduces routing complexity by orders of magnitude while satisfying load balancing by construction. Pre-trained on over 60,000 multi-phase CT scans, A^{2}$MoE achieves state-of-the-art performance across segmentation, classification, and detection benchmarks. Furthermore, we demonstrate that our anatomically grounded inductive biases support robust generalization to MRI and ultrasound, establishing a scalable foundation for medical representation learning.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
22 Apr 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:46 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

The paper proposes A2MoE, a 3D medical vision-language pre-training framework that introduces anatomical priors directly into expert routing and organ-level image–text alignment. The reviewers view the problem as well motivated, and the two components proposed along with A2MoE, namely HRR and OQMSP, as reasonably original. These components were validated across segmentation, classification, and detection benchmarks. Moreover, the effects span CT, MRI, and ultrasound [isoH, bN4a, Jq6Y]. The main weakness is that it remains unclear how much of the improvement comes from the proposed anatomy-aware mechanisms rather than increased model capacity, large-scale pre-training, pseudo-label supervision, and report decomposition [isoH, bN4a]. The computational-efficiency claims are also insufficiently quantified, and the paper provides limited evidence that the predicted anatomy histogram and organ queries behave as intended [isoH]. The response should therefore prioritize controlled or parameter-normalized comparisons to alternative approaches, FLOPs/memory/runtime information, clarification of whether all experts are evaluated, and evidence on histogram accuracy and organ-query localization. Clarifying the PANORAMA metrics, “mask-free” terminology, report-verification procedure, notation issues, and please remove the artifact pointed by two reviewers [isoH, Jq6Y].

Final justification

I would like to acknowledge that the reviewers and I read the responses offered by the authors. Based on reviewers' increased scores and my own analysis, most of the concerns raised in the reviews and the meta-review were sufficiently addressed. Taking this into account, I am confident in recommending this paper for acceptance.

Area Chair p3ep · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

The paper proposes A2MoE, a 3D medical vision-language pre-training framework that introduces anatomical priors directly into expert routing and organ-level image–text alignment. The reviewers view the problem as well motivated, and the two components proposed along with A2MoE, namely HRR and OQMSP, as reasonably original. These components were validated across segmentation, classification, and detection benchmarks. Moreover, the effects span CT, MRI, and ultrasound [isoH, bN4a, Jq6Y]. The main weakness is that it remains unclear how much of the improvement comes from the proposed anatomy-aware mechanisms rather than increased model capacity, large-scale pre-training, pseudo-label supervision, and report decomposition [isoH, bN4a]. The computational-efficiency claims are also insufficiently quantified, and the paper provides limited evidence that the predicted anatomy histogram and organ queries behave as intended [isoH]. The response should therefore prioritize controlled or parameter-normalized comparisons to alternative approaches, FLOPs/memory/runtime information, clarification of whether all experts are evaluated, and evidence on histogram accuracy and organ-query localization. Clarifying the PANORAMA metrics, “mask-free” terminology, report-verification procedure, notation issues, and please remove the artifact pointed by two reviewers [isoH, Jq6Y].

Final justification

I would like to acknowledge that the reviewers and I read the responses offered by the authors. Based on reviewers' increased scores and my own analysis, most of the concerns raised in the reviews and the meta-review were sufficiently addressed. Taking this into account, I am confident in recommending this paper for acceptance.

1 comment
Authors · CommentOpenReview ↗

Rebuttal and discussion summary

We sincerely thank the Area Chair for their guidance and for synthesizing the Reviewers' constructive feedback. We used these insights to systematically address all concerns raised by the Reviewers during the discussion period. We are pleased to report that we have successfully addressed every weakness and question raised across all three reviews. In particular, we have resolved technical and typographical errors, added a computational benchmark, conducted crucial ablation studies across all downstream tasks, demonstrated the architectural generality of our modules on an alternative backbone (i.e., Swin UNETR), and validated our performance on official challenge metrics.

A detailed summary of what changed during the discussion period, along with direct mapping to the reviewer comments, is provided below.

New Experiments and qualitative validation

  • Evaluated training/inference wall-clock time, FLOPs, and VRAM across all baseline models. Re-calculated true trainable parameter counts to clarify that our VLM model adds minimal overhead (~4M parameters from OQMSP, total ~83.5M parameters excluding the discarded pre-training text encoder) while offering superior compute-accuracy trade-offs. [isoH W4, Q2; bN4a W1]
  • Extended our ablation studies beyond segmentation to RATIC classification and AbdomenAtlas 3.0 detection, demonstrating consistent gains across all tasks. [bN4a W2]
  • Implemented and evaluated our framework (A$^{2}$MoE + OQMSP) using Transformer-based backbone (i.e. Swin UNETR) alongside SegMamba (SSMs) across six downstream datasets, demonstrating consistent performance improvements regardless of the underlying token-mixing operator. [Jq6Y W2]
  • Re-evaluated performance on pancreatic cancer detection using official PANORAMA metrics, including AUROC and Average Precision (AP), alongside DSC and HD95 on independent testing cohorts, outperforming state-of-the-art baselines. [Jq6Y W3]
  • Measured inference-time histogram prediction accuracy on AMOS-CT and bounded its downstream segmentation impact using a Uniform vs. Predicted vs. Oracle GT routing control bracket. [isoH Q1]
  • Performed pointing-game accuracy evaluations across 14 foreground organ queries, confirming that queries consistently bind to specific organ identities rather than acting as unconstrained latent slots. [isoH Q3]

Clarification

  • Clarified throughout the manuscript that the term "mask-free" specifically refers to inference time, explicitly noting in the Limitations section that the pre-training pipeline relies on pseudo-labels and LLM-based report decomposition. [isoH W3]
  • Explicitly detailed in Sections 4.1–4.2 and Table captions the exact level of supervision, pseudo-labeling, and report alignment used during pre-training across both our model and all baseline models. [isoH W5]
  • We did Methodology notation section revision [Jq6Y W1]
  • Corrected Table 4 and text descriptions to accurately reflect the 14 foreground organ categories. [isoH W2]
  • Deleted the formatting prompt snippet artifact. [isoH W1]
  • Clarified that manual radiologist verification covered 100% of the pre-training studies via a custom interface, and committed to releasing organ snippet annotations for the public Merlin subset. [isoH Q4]

We believe these additions and clarifications thoroughly address every point raised by Reviewers isoH, bN4a, and Jq6Y - all of whom raised their scores - significantly strengthening our submission. Given these improvements, we hope the AC will find our work to be a valuable, high-impact contribution to the NeurIPS community.

Reviewer Jq6YOpenReview ↗
Rating
5/6
Confidence
5/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
use_inspired
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

A2MOE is proposed - a novel mixture-of-experts method for 3D medical vision-language pretraining that intrinsically leverages the anatomical priors captured in given scans. There are two distinct methodological contributions: 1) a histogram representation router and 2) a mask free organ query multi-scale projector. The first component ensures that the model routing is guided by anatomical structure information, focusing the computation in a meaningful way. The second component, enables vision-language alignment - leveraging organ specific visual embeddings while avoiding the need for segmentation masks during inference. The validation is based on public datasets, with downstream experiments focused on segmentation, classification and detection. Overall the paper is well written, the validation is extensive and detailed.

Strengths and weaknesses

Strengths:

  • The article is well structured and overall well written (perhaps with one exception, captured under weaknesses) - especially the introduction and related work lay out a clear problem statement, with the proposed solution clearly motivated.
  • The proposed method is elegant and innovative. Through the two proposed components (A2MOE and OQMSP) it addresses clear challenges, optimizing the pre-training by leveraging the anatomical information, while at the same time maintaining efficiency. The inference scheme is lightweight making the model easy to use downstream.
  • The experimental validation is extensive, a large database of over 60k CT are used for training while downstream validation focused on segmentation, classification and detection - covering central tasks in the medical image analysis domain. The are extensive details on how the reports are processed (great!) as well as for the experiments, the analysis includes lots of details on preprocessing, metrics, ablation analysis, etc.

Weaknesses:

  • While the article is overall well written, IMHO the methodology section 3 could use a round of revision, with the focus on increased clarity, and revising mathematical notation (e.g., there is variable C and C_s referring to very different things, Eq. 3 uses index b, I assume for the batch? index s is sometimes used as superscript, other times as subscript; eventually even variable s_{(s)} is used). I believe a revision with focus on notation consistency, simplicity and clarity will boost readability, and allow the reader to focus much more easily.
  • The proposed method is generic, meaning it could extend beyond the segmamba backbone (fact acknowledged by the authors in the future directions). It is unfortunate that this aspect is not more central to the paper. I would not have expected to see the same depth of analysis with other backbones, but this backbone "invariance" is super-important for the practical impact of the proposed method. It would have been great to see even a couple of experiments, maybe focused only on one downstream - just the get a flavor.
  • Focusing on the PANORAMA challenge: it would be great to maintain the metrics from the challenge, AUC + AP; instead of redefining a new DICE-based score. The PANORAMA challenge is also highly regarded in the community, validating your method in accordance to the challenge guideline will position your results against a few quite powerful approaches, helping the reader assess the true performance against the state-of-the-art.
Questions

Based on the section on strengths/weaknesses, the following changes will help boost the quality of the paper:

  • Revising the methodology section 3 with the focus on increased clarity, and improved mathematical notation. believe a revision with focus on notation consistency, simplicity and clarity will boost readability, and allow the reader to focus much more easily. I added a few concrete examples in the previous section on "weaknesses".
  • Focus on PANORAMA and include the validation on the challenge metrics: AUC (patient-level likelihood score) and AP (PDAC detection map). This would allow you to include the results in the article and position the performance of your approach against a couple of very strong reference solutions.
  • (Bonus): the topic of different backbones - I believe this would be super, super relevant and broadening the scope of the paper and increasing the impact. Even a dedicated section on this aspect (without experiments), discussing potential challenges that are anticipated, would be great.
Limitations

Excellent section J on limitations and future work!

Final justification

Great rebuttal with clear answers to my main comments.

Formatting concerns

No concerns!

3 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We thank the reviewer for a constructive review that identifies concrete, actionable improvements.

W1, Q1: [...] the methodology section 3 could use a round of revision [..]

We agree with reviewer. We have thoroughly revised Section 3 to ensure full mathematical rigor and clarity regarding Section 3 in revised manuscript. The following inconsistencies have been fixed:

  • CC vs. CsC_s: CC now denotes only the number of anatomical classes. The stage channel width has been renamed to DsD_s (formerly CsC_s), eliminating the notation conflict.

  • Batch index bb: All equations are now presented for a single sample, with the batching convention stated once at the beginning of Section 3. The stray hb,ch_{b,c} in Equation 3 no longer includes an explicit batch index.

  • Stage index ss: Stage indices are now used consistently as subscripts (like Xs\mathbf{X}_s, As\mathbf{A}_s, Ψgate,s\Psi_{\text{gate}, s}). Mixed subscript/superscript notation has been removed.

  • s(s)\mathbf{s}_{(s)}: The stage embedding has been renamed to gs\mathbf{g}_s, eliminating the self-indexed symbol notation.

We believe these changes make Section 3 substantially easier to follow and let the reader focus on the method.

W2, Q3 (bonus): Backbone generality

We sincerely thank the reviewer for this insightful suggestion. We agree that discussing how our proposed framework (A$^{2}$MoE + OQMSP) generalizes across different architectural backbones, such as Vision Transformers (Swin UNETR) vs. State Space Models (SegMamba), substantially broadens the scope and impact of our paper. We have strengthened it in two ways.

  1. Architecturally, A$^{2}MoEisadrop−insubstitutionrequiringnobackbone−specificchange:theAMoE is a drop-in substitution requiring no backbone-specific change: the A^{2}MoElayerreplacestheper−stagechannelMLP—a1MoE layer replaces the per-stage channel MLP — a 1\times$1$\times$1-convolution feed-forward block present in essentially every 3D encoder — and OQMSP uses an arbitrary multi-scale pyramid, parameterised only by per-stage channel widths and key/value strides. Neither component assumes anything about the token-mixing operator (state-space, attention or convolution). This is now stated explicitly in Sec. 3.3 in revised manuscript.

  2. Empirically, we substituted the SegMamba backbone with the Swin UNETR backbone and re-ran on the downstream segmentation task for several datasets, including AMOS-CT, PANORAMA, AMOS-MRI, GEPAR3D, MRISegmenter and MVSeg.

Configuration Params VRAM AMOS-CT PANORAMA AMOS-MRI GEPAR3D MRISegmenter MVSeg
M G DSC (HD95) DSC (HD95) DSC (HD95) DSC (HD95) DSC (HD95) DSC (HD95)
Swin UNETR 62.2 4.4 83.8 (28.4) 73.8 (10.2) 74.6 (14.5) 83.2 (12.4) 72.1 (8.7) 81.9 (7.2)
+ A$^{2}$MoE 76.2 4.5 83.9 (9.2) 76.1 (8.4) 76.8 (13.8) 84.5 (9.8) 75.4 (7.6) 82.8 (5.6)
+ OQMSP 80.2 4.6 87.2 (7.5) 77.3 (6.9) 80.2 (10.3) 86.2 (9.2) 77.5 (6.3) 83.9 (4.9)
SegMamba 65.5 2.9 85.5 (26.1) 76.0 (8.6) 76.7 (9.3) 85.3 (10.6) 74.5 (6.8) 83.8 (5.8)
+ A$^{2}$MoE 79.5 3.0 87.5 (7.6) 78.2 (7.1) 78.5 (12.2) 86.1 (7.9) 77.6 (5.9) 84.5 (4.4)
+ OQMSP 83.5 3.1 88.7 (6.2) 79.1 (5.8) 82.3 (8.9) 87.7 (8.1) 79.8 (5.5) 85.4 (4.0)

We demonstrated that our proposed key modules, A$^{2}$MoE and OQMSP, consistently improve performance across different backbones.

W3, Q2: Focus on PANORAMA and include the validation on the challenge metrics [...]

Following the PANORAMA challenge paper [1], we fine-tuned each configuration with the training cohort from the Netherlands (RUMC, Nijmegen and UMCG, Groningen). Because the official test set is not available, we extracted data from two independent sets (NIH, USA, and MSD, USA) to test our performance. Additionally, we used in-house dataset with N=60N=60 PDAC cases with voxel-wise annotation masks provided by experienced radiologists to demonstrate generalizability.

As previously, we provided DSC and HD95 metrics, we incorporate metrics used in PANORAMA challenge, including AUROC and AP.

Method DSC (%) HD95 (mm) AUROC AP
VoCo 71.6 16.9 0.824 0.582
uC 3DU-Net 76.6 4.7 0.878 0.638
SuPreM 76.6 4.7 0.876 0.635
SegMamba 76.0 8.6 0.865 0.618
Mamba-HoME 77.5 4.8 0.889 0.655
Merlin 77.5 9.4 0.892 0.660
fVLM 76.8 9.8 0.871 0.627
BTB3D 77.3 9.2 0.890 0.685
Ours 79.1 5.8 0.918 0.702

We demonstrated that our proposed method outperformed state-of-the-art methods across several metrics, both in terms of segmentation quality and PANORAMA challenge-based AUROC and AP.

References:

[1] Alves, Natalia, et al. "Artificial intelligence and radiologists in pancreatic cancer detection using standard of care CT scans (PANORAMA): an international, paired, non-inferiority, confirmatory, observational study." The Lancet Oncology (2025).

We hope this addresses all concerns. Should any further questions arise, we remain fully available throughout the discussion period. In light of this rebuttal, we kindly ask the reviewer to consider increasing their score.

Authors · CommentOpenReview ↗

Friendly follow-up

Dear Reviewer,

Since the author-reviewer discussion is coming to an end, we would be grateful if the reviewer could comment whether the rebuttal has addressed their concerns, and if yes, whether they would be willing to increase their score.

Best regards,

Authors

Reviewer Jq6Y · CommentOpenReview ↗

Thank you for the super-response!

Thanks you for addressing my comments in such detail - I am very happy and will increase my score to "Accept".

Reviewer bN4aOpenReview ↗
Rating
5/6
Confidence
2/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
use_inspired
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper proposes Anatomy-Activated Mixture-of-Experts (A²MoE), a 3D medical vision-language pre-training framework that incorporates anatomical information into the model’s internal computation. The method introduces a Histogram Representation Router to guide expert selection using global visual context and predicted anatomy-presence information, and an Organ-Query Multi-Scale Projector to extract organ-level visual embeddings for alignment with organ-specific report text. The model is pre-trained on over 60,000 CT-report pairs and evaluated on segmentation, classification, and detection tasks across CT, MRI, and ultrasound datasets.

Strengths and weaknesses

The work is technically well motivated: standard dense encoders and conventional MoE routers are largely anatomy-agnostic, while the proposed Histogram Representation Router conditions expert selection on anatomical presence information, and the Organ-Query Multi-Scale Projector extracts organ-level visual embeddings for alignment with organ-specific report text. The empirical evaluation is also broad, covering segmentation, classification, and detection across CT, MRI, and ultrasound datasets, and the ablation studies provide evidence that both the anatomy-aware routing and the organ-query alignment contribute to performance. For significance, the work addresses an important limitation in 3D medical VLP by moving anatomical grounding from a post-hoc alignment objective into the model’s internal computation, which is meaningful for medical imaging because similar visual patterns can have different diagnostic implications depending on the organ context. The originality is reasonably strong, especially in combining anatomy-conditioned MoE routing with mask-free organ-query projection for 3D medical representation learning.

However, the full model introduces substantially more parameters than the base SegMamba model, making it difficult to isolate whether improvements come from the proposed anatomy-aware mechanism or simply from increased capacity. Second, the ablation analysis is stronger for segmentation than for the other downstream tasks; it is less clear whether the same components are equally responsible for the classification and detection gains.

Questions

See strengths and weaknesses.

Limitations

Yes

Final justification

The additional ablation studies address my concern regarding the absence of results for classification and detection downstream tasks, thus strengthening my confidence about the work.

Formatting concerns

No obvious converns.

3 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We thank the reviewer for a thorough and generous assessment of the motivation, breadth of evaluation, and originality of the work. We address their comments below.

W1: The full model introduces substantially more parameters than the base SegMamba model [...]

This is a fair concern, and we realize our parameter reporting was misleading. The reported parameter gap is largely an accounting artifact. The 203.1M count for the full model includes the frozen PubMedBERT text encoder (119.6M), which was used only for pre-training alignment and discarded during downstream inference; OQMSP itself contributes only ~4M. We recomputed the trainable parameters and obtained the following: (i) SegMamba – 65.5M, (ii) SegMamba + A$^{2}MoE–∗∗79.5M∗∗,and(iii)SegMamba+AMoE – **79.5M**, and (iii) SegMamba + A^{2}$MoE + OQMSP – 83.5M. Thus, our proposed VLM model is comparable to other state-of-the-art VLMs used for comparison, such as fVLM and BTB3D, and significantly lower than Merlin. We now clarified this in the revised submission.

W2: The ablation analysis is stronger for segmentation than for the other downstream tasks [...]

We agree this was a gap and have extended the #1/#2/#3 ablation ladder to both remaining tasks.

For RATIC classification, we report the ROC-AUC for each of the four classes, as well as their mean:

Config Bowel Liver Kidney Spleen ROC-AUC
#1 SegMamba 73.2 77.1 90.5 89.0 83.0
#2 + A$^{2}$MoE 78.7 81.6 92.5 90.9 86.1
#3 + OQMSP (ours) 82.4 84.6 93.8 92.1 88.2

For AbdomenAtlas 3.0 detection, we report Sensitivity (Sen.) for ≤\leq 2 cm and >\gt 2 cm lesions, and Specificity (Spec.):

Config Pancreatic tumor Kidney tumor Liver tumor
Sen. (≤\leq 2cm) Sen. (> 2cm) Spec. Sen. (≤\leq 2cm) Sen. (> 2cm) Spec. Sen. (≤\leq 2cm) Sen. (> 2cm) Spec.
#1 SegMamba 44.3 66.7 88.5 42.1 78.5 45.0 28.5 83.0 76.2
#2 A$^{2}$MoE 58.6 75.0 91.8 50.3 88.0 50.2 35.1 90.4 81.0
#3 + OQMSP (ours) 66.7 83.3 94.1 58.2 94.1 55.4 41.2 95.2 85.4

We demonstrated that our proposed key modules (A$^{2}$MoE and OQMSP) consistently improved the performance across all compared downstream tasks, including segmentation, classification and detection.

We will incorporate these complete ablation results into the camera-ready version of the manuscript.

We hope this addresses all concerns. Should any further questions arise, we remain fully available throughout the discussion period. In light of this rebuttal, we kindly ask the reviewer to consider increasing their score.

Authors · CommentOpenReview ↗

Friendly follow-up

Dear Reviewer,

Since the author-reviewer discussion is coming to an end, we would be grateful if the reviewer could comment whether the rebuttal has addressed their concerns, and if yes, whether they would be willing to increase their score.

Best regards,

Authors

Reviewer bN4a · CommentOpenReview ↗

I thank authors for the detailed response. The ablations substantially address my concern regarding diverse tasks. I increased the score.

Reviewer isoHOpenReview ↗
Rating
4/6
Confidence
4/5
Quality
2/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper proposes A2MoE, an anatomy-aware mixture-of-experts (MoE) framework for 3D medical vision-language pretraining. The core idea is to explicitly inject anatomical priors into the model’s computational pathway, rather than treating them merely as a post-hoc alignment signal. The method consists of an HRR router, which determines expert weights using global visual context, an organ presence histogram, and class-to-expert affinity; and OQMSP, which employs learnable organ queries to extract organ-level visual representations from multi-scale features and align them with organ-level report text. The paper reports strong performance on CT/MRI/ultrasound segmentation, trauma classification, and tumor detection tasks.

Strengths and weaknesses

Strengths:

  1. The paper presents a clear and medically well-motivated problem formulation. Since visual patterns in medical imaging are highly dependent on organ context, incorporating anatomical priors into the routing mechanism is more aligned with clinical diagnostic logic than relying solely on image-text contrastive alignment.

  2. The proposed HRR and OQMSP modules are both novel and well designed. In particular, HRR leverages crop/stage-level anatomy histograms and class-to-expert affinity matrices to encourage expert specialization, which may help reduce semantic collisions across different organs. OQMSP, on the other hand, provides a valuable organ-level alignment mechanism by enabling soft organ pooling through learnable organ queries without relying on ground-truth masks during inference.

  3. The experimental evaluation is comprehensive and demonstrates strong generalization. The method is evaluated across multiple segmentation benchmarks, including AMOS-CT, PANORAMA, AMOS-MRI, GEPAR3D, MRISegmenter, and MVSeg, as well as on RATIC classification and AbdomenAtlas detection. The improvements are reflected not only in Dice scores but also in HD95, suggesting that anatomy-aware routing may indeed improve robustness to boundary errors and distant mis-segmentation.

Weakness:

  1. The manuscript contains an LLM prompt artifact at Lines 218–219: “To combine the first two equations into one line and leave the third as its own line, use the following LaTeX code:”.

  2. There is an inconsistency in the reported number of organ categories. At Lines 715–718, the manuscript states that “we directly extract 15 key abdominal organs, including spleen, left kidney, right kidney, gallbladder, liver, stomach, pancreas, left adrenal gland, right adrenal gland, duodenum, small bowel, colon, urinary bladder, and prostate,” yet this list actually contains only 14 organ categories.

  3. The term “mask-free” may be overly strong. Although OQMSP does not require masks at inference time, the pretraining pipeline relies heavily on TotalSegmentator pseudo-labels, LLM-based organ-level text decomposition, and validation by radiologists. Therefore, a more accurate description would be inference-time mask-free rather than mask-free throughout the entire training pipeline.

  4. The computational advantages of the MoE design should be quantified more thoroughly. It would be helpful to report training/inference wall-clock time, FLOPs, memory consumption, and parameter-normalized performance.

  5. The fairness of the comparisons requires further clarification. A2MoE benefits from large-scale CT-report pretraining, organ pseudo-labels, and report decomposition, whereas it is not fully clear whether all baselines are provided with a comparable level of organ-level supervision. The paper should more explicitly disentangle architectural gains, pretraining data gains, and supervision pipeline gains.

Questions
  1. How accurate is the histogram predicted by the presence head during inference? Have the authors evaluated the KL divergence or correlation between the predicted histogram and the pseudo-label histogram, and examined how errors in histogram prediction affect downstream performance?

  2. Does A2MoE compute all experts in every forward pass? If so, could the authors provide a comparison with SegMamba and Mamba-HoME in terms of FLOPs, memory consumption, and training/inference time?

  3. Is there any visualization or quantitative localization evaluation for the organ query attention in OQMSP? Do these queries consistently correspond to specific organs, or do they primarily function as latent slots?

  4. The report decomposition uses Qwen3-30B-A3B and is followed by radiologist verification. Does this manual verification cover the entire training set, or is it performed on a sampled subset? If the latter, how is the error rate estimated?

Limitations

yes

Final justification

The article mentions that some low-level errors in comparing LLM prompts and category descriptions have been resolved, and some training resource analysis has also been addressed.

Formatting concerns

The manuscript contains an LLM prompt artifact at Lines 218–219: “To combine the first two equations into one line and leave the third as its own line, use the following LaTeX code:”.

1 comment
Authors · RebuttalOpenReview ↗
Rebuttal

We thank the reviewer for the positive assessment. We appreciate the constructive comments regarding terminology, computational analysis, and further validation of the proposed components. We address each point below.

W1: LLM prompt arficact

Thank you for catching this. The sentence "To combine the first two equations into one line and leave the third as its own line, use the following LaTeX code:" was introduced while formatting the OQMSP equation block. It has been deleted in revised manuscript.

W2: There is an inconsistency in the reported number of organ categories [...]

The intended number is 14 foreground organs. The enumerated list in the text is the correct one; the count and the table were wrong. In Table 4 we removed the Esophagus row and renumbered classes 10–14, giving background + 14 organs.

W3: The term “mask-free” may be overly strong [...]

We agree, and have adopted "inference-time mask-free" consistently in revised manuscript. We have also added one sentence to the limitations noting that the pre-training pipeline does depend on pseudo-labels and LLM decomposition.

W4: The computational advantages of the MoE design should be quantified more thoroughly [...]

We have measured all compared methods under a matched protocol and will include the following table in the revised manuscript as requested.

Method GFLOPs VRAM (G) Training time (patches/s)†^\dagger Inference time (s/scan)‡^\ddagger
VoCo 1850 4.4 2.1 3.8
uC3DUNet 1110 3.1 4.1 2.2
SuPreM 1960 4.4 2.0 3.9
Mamba-HoME 1610 3.7 2.3 3.0
Merlin 2400 13.8 1.0 7.5
fVLM 1600 4.5 2.2 3.8
BTB3D 1620 7.6 1.6 5.2
SegMamba 1560 2.9 3.4 2.6
A$^{2}$MoE 1630 3.0 3.0 2.8

†\dagger Means the number of patches in 128 ×\times 128 ×\times 128 resolution per second on N=160N=160 CT scans from AMOS-CT training set, with a batch size B=1B=1. ‡\ddagger Means the average second per scan on N=100N=100 CT scans from AMOS-CT test set. Please note, for test we used their original resolution.

Parameter-normalized performance. The accuracy gains of A$^{2}$MoE over SegMamba (e.g. AMOS-CT 85.5 →\rightarrow 87.5 DSC) are obtained with only ~+4–7% FLOPs and +0.1 GB VRAM, whereas larger models such as Mamba-HoME and Merlin do not surpass A$^{2}$MoE on this compute–accuracy trade-off. All methods were evaluated on the AMOS-CT test set at full resolution using single A100 80GB.

W5: The fairness of the comparisons requires further clarification [...]

We agree it should be stated more explicitly. Our experimental design already separates these factors; we clarify the protocol below and will make it prominent in Sections 4.1–4.2 and the Table 1 caption. In original submission (Table 1), †\dagger denotes models initialized from pre-trained weights (released checkpoints for external methods; our own CT–report pre-trained weights for A$^{2}$MoE and OQMSP #3).

Modality-matched supervision in our pre-training. For A$^{2}$MoE, pre-training uses CT scans + pseudo-labels for anatomy-conditioned routing/segmentation objectives, and additionally organ-level report decomposition for OQMSP image–text alignment. Segmentation-oriented baselines that admit dense label supervision are trained with CT scans + pseudo-labels under the same experimental settings; VLM baselines that require text features use CT + pseudo-labels + reports in their original pre-training.

Additionally, we did ablation studies on classification and detection downstream tasks to demonstrate the gain of performance provided by each key architecture component. We kindly refer to W2 [bN4a]. We will clarify it in camera-ready version.

Q1: How accurate is the histogram predicted by the presence head during inference? [...]

We evaluate the presence head on the AMOS-CT test set by comparing the inference-time prediction h^=softmax⁡(Ψpres(vs))\hat{\mathbf{h}}=\operatorname{softmax}(\Psi_{\mathrm{pres}}(\mathbf{v}_s)) to the crop-level pseudo-label histogram h\mathbf{h} computed from the ground-truth masks.

Across AMOS-CT test crops we obtain mean KL(h ∥ h^)=0.22\mathrm{KL}(\mathbf{h}\,\|\,\hat{\mathbf{h}})=0.22 and mean per-class Pearson correlation r=0.82r=0.82. Treating histogram mass as an organ-presence score, binary AUROC is approximately 0.920.92 for large organs (liver, spleen, kidneys, stomach) and 0.760.76 for small or thin structures (adrenal glands, duodenum, gallbladder). Errors concentrate on low-prevalence classes whose absolute voxel fraction is small; background-dominated crops inflate absolute KL less than they hurt small-organ calibration.

Effect on downstream segmentation. To measure how histogram error propagates, we compare three routing settings at identical parameter count on AMOS-CT:

Inference routing DSC (%)
Uniform (average all experts equally) 86.1
Presence head h^\hat{\mathbf{h}} (this work) 88.7
Oracle GT (h\mathbf{h} from the GT on the test crop) 89.5

Anatomy-conditioned routing with the predicted histogram improves over the uniform control by +2.6+2.6 DSC. Replacing h^\hat{\mathbf{h}} by the oracle histogram yields an additional 0.80.8 DSC. Thus presence-head errors are not negligible, but they account for only part of the HRR gain: most of the benefit of anatomy-aware routing remains under realistic histogram prediction. We will report per-organ KL/correlation and this uniform--predicted--oracle bracket in the revised manuscript.

Q2: Does A2MoE compute all experts in every forward pass? [...]

Yes, A$^{2}$MoE is based on soft MoE, as described in Preliminaries (see Appendix) and computes all experts in every forward pass. Here, we provide a comparison with SegMamba and Mamba-HoME in terms of FLOPs, memory consumption, training and inference time.

Method GFLOPs VRAM (G) Training time (patches/s)†^\dagger Inference time (s/scan)‡^\ddagger
SegMamba 1560 2.9 3.4 2.6
Mamba-HoME 1610 3.7 2.3 3.0
A$^{2}$MoE 1630 3.0 3.0 2.8

For the definitions of †\dagger and ‡\ddagger, please refer to W4.

Q3: Is there any visualization or quantitative localization evaluation for the organ query attention in OQMSP? [...]

OQMSP uses one learnable query per non-background organ (14 queries), shared across all pyramid stages. Soft localization maps are given by softmax(Q~sKs⊤)\text{softmax}(\tilde{Q}^s {K^s}^\top) at each stage; we upsample them to the label grid, fuse stages with the learned scale weights, and compare against organ pseudo-masks on the validation set.

For organ query q∈{1,…,C−1}q \in \{1,\dots,C-1\} and sample bb, let αb,q(j)\alpha_{b,q}(j) denote the fused OQMSP attention map after multi-scale aggregation and upsampling to the label grid Ω\Omega, normalized as a spatial distribution:

\alpha_{b,q}(j)\ge 0, \qquad \sum_{j\in\Omega}\alpha_{b,q}(j)=1.$$ Let $L_b(j)\in\{0,1,\dots,C-1\}$ be the voxel-wise organ label (with $0$ denoting background), and define the ground-truth mask of organ $q$ as $M_{b,q} = \{ j \in \Omega : L_b(j) = q \}$. When attention maps are produced at multiple encoder stages $s\in\{1,\dots,4\}$, we form the fused map: $$\alpha_{b,q} = \sum_{s=1}^{4} \alpha_s\, \mathcal{U}\!\bigl(\alpha^{(s)}_{b,q}\bigr),

where α=softmax⁡(α1,…,α4){\alpha}=\operatorname{softmax}(\alpha_1,\dots,\alpha_4) are the learned OQMSP scale weights and U\mathcal{U} upsamples to Ω\Omega, followed by re-normalization so that ∑jαb,q(j)=1\sum_{j}\alpha_{b,q}(j)=1.

We report pointing-game accuracy, whether the attention peak falls inside the target organ. We take the peak location of query qq as: $jb,q⋆=arg⁡max⁡j∈Ω αb,q(j).j^{\star}_{b,q} = \arg\max_{j\in\Omega}\,\alpha_{b,q}(j).$

A prediction is counted as correct if the peak falls inside the matched organ:

PGb,q=1[jb⋆,q∈Mb,q]=1[Lb(jb⋆,q)=q].\mathrm{PG}_b,q = \mathbf{1}\bigl[j^{\star}_b,q \in M_b,q\bigr] = \mathbf{1}\bigl[L_b(j^{\star}_b,q)=q\bigr].

Let Bq={b:∣Mb,q∣>0}B_q=\{b : |M_{b,q}|>0\} be the set of samples in which organ qq is present. The per-organ and mean pointing-game scores are:

PGq=1∣Bq∣∑b∈BqPGb,q,PG=1C−1∑q=1C−1PGq.\mathrm{PG}_q = \frac{1}{|B_q|} \sum_b\in B_q \mathrm{PG}_{b,q}, \qquad \mathrm{PG} = \frac{1}{C-1} \sum_q=1^{C-1} \mathrm{PG}_q.
Organ Pointing (%)
Liver 88
Spleen 84
Kidney left 80
Kidney right 78
Stomach 76
Colon 74
Bladder 72
Pancreas 70
Prostate 68
Gallbladder 62
Small bowel 58
Duodenum 55
Adrenal gland left 50
Adrenal gland right 48

Organ-specific queries vs. latent slots. Mean pointing ~69% indicate that queries consistently correspond to fixed organ identities rather than unrestricted latent slots. Residual confusion is structured and clinically expected: kidneys, adrenal glands, and adjacent GI pairs (e.g. pancreas–duodenum, bowel–colon), rather than arbitrary cross-organ mixing. In camera-ready version, we will provide attention-map visualizations showing organ-consistent localization.

Q4: The report decomposition uses Qwen3-30B-A3B and is followed by radiologist verification. Does this manual verification cover the entire training set, or is it performed on a sampled subset? [...]

We verified all pre-training studies using a custom interface displaying source reports alongside extracted snippets. Four radiologists (≥5 years experience) reviewed every organ-level snippet with single-action accept/edit/reject, while a senior radiologist (>30 years experience) adjudicated disputed cases. We will release these snippets for the public Merlin subset to support research and update the manuscript accordingly.

We hope this addresses all concerns. Should any further questions arise, we remain fully available throughout the discussion period. In light of this rebuttal, we kindly ask the reviewer to consider increasing their score.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.