potentialpaper

TACT-KV: Tri-Axis Cosine Transform for Compressing Volumetric KV Caches in Medical VLMs

Chongyu Qu, Ritchie Zhao, Yufan He, Dong Yang, Zhengyi Lu, Junchao Zhu, Tianyuan Yao, Juming Xiong, Junlin Guo, Yanfan Zhu, Yuechen Yang, Daguang Xu, Bennett Allan Landman, Yucheng Tang, Yuankai Huo

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

TL;DR. TACT-KV exploits 3D spatial structure for 1-bit visual KV cache compression, largely preserving model predictions while enabling up to 8× larger decoding batches.

Abstract. Vision-language models (VLMs) applied to 3D medical scans face a structural memory wall. A single CT or MRI volume produces tens of thousands of vision tokens, and the resulting key-value (KV) cache scales linearly with both batch and context. Existing KV compression methods operate on the cache's feature or token statistics, or apply 1D and 2D transforms, leaving the three-axis spatial structure in the cache unexploited. We propose TACT-KV (Tri-Axis Cosine Transform), a calibration-free KV compression method that exploits strong spatial correlations in visual KV states along all three anatomical axes of 3D scans. This correlation concentrates the KV cache energy under a frequency-domain transform. TACT-KV applies a separable 3D discrete cosine transform to the KV cache, allocates a per-layer bit budget across frequency bins via reverse water-filling (more bits to high-energy components), and quantizes each bin with a fixed scalar codebook. We derive a close-form relation: the distortion reduction from adaptive bit allocation is dominated by the spectral concentration of the transformed cache. Across six medical VLMs and two 3D CT benchmarks, TACT-KV achieves the lowest 1-bit prediction-flip rate on eleven of twelve model and dataset pairs in our main comparison. The same advantage reproduces on four general-purpose VLMs evaluated on video tasks, indicating that the benefit of exploiting three-axis structure generalizes beyond medical imaging. At equal high-bandwidth memory (HBM), TACT-KV scales the decoding batch size on a single GPU by up to 8×.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
22 Apr 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:45 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

The paper is reviewed by three experts.

Reviewer 'mRWS' (R1) acknowledges that the paper addresses an important problem (a real deployment bottleneck), proposes a technically coherent method with a sensible design, conducts a broad range of experiments that involve multiple medical VLMs and video VLMs, and provides useful implementation and reproducibility details. R1 is concerned about the main metric, insufficient baseline coverage (for the strongest claims), overstated theoretical contribution, incomplete deployment evidence, etc. R1 recommends 'borderline reject'.

Reviewer 'gVi3' (R2) thinks that the paper is well motivated, proposes a novel method, and obtaines good results. R2 is concerned about missing certain experiments and reporting specifics. R2 recommends 'borderline accept'.

Reviewer 'Nguf' (R3) thinks that the paper is novel and technically sound in its core contribution, well-written and precise in its terminology, and with a clear and well-framed significance. R3 recommends 'accept'.

In sum, the paper has more strengths than weaknesses. The concerns from R1 and R2 are detail-oriented and addressable.

Hence, it is recommended to accept the paper.

Final justification

The paper is reviewed by three experts.

Reviewer 'mRWS' (R1) acknowledges that the paper addresses an important problem (a real deployment bottleneck), proposes a technically coherent method with a sensible design, conducts a broad range of experiments that involve multiple medical VLMs and video VLMs, and provides useful implementation and reproducibility details. R1 is concerned about the main metric, insufficient baseline coverage (for the strongest claims), overstated theoretical contribution, incomplete deployment evidence, etc. R1 recommends 'borderline reject'. After rebuttal, R1 increases the score to 'borderline accept'.

Reviewer 'gVi3' (R2) thinks that the paper is well motivated, proposes a novel method, and obtaines good results. R2 is concerned about missing certain experiments and reporting specifics. R2 recommends 'borderline accept'.

Reviewer 'Nguf' (R3) thinks that the paper is novel and technically sound in its core contribution, well-written and precise in its terminology, and with a clear and well-framed significance. R3 recommends 'accept'.

In sum, the paper has more strengths than weaknesses. The concerns from R1 and R2 are detail-oriented and addressable. These concerns are mostly addressed by the rebuttal.

Hence, it is recommended to accept the paper.

Area Chair Ec8H · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

The paper is reviewed by three experts.

Reviewer 'mRWS' (R1) acknowledges that the paper addresses an important problem (a real deployment bottleneck), proposes a technically coherent method with a sensible design, conducts a broad range of experiments that involve multiple medical VLMs and video VLMs, and provides useful implementation and reproducibility details. R1 is concerned about the main metric, insufficient baseline coverage (for the strongest claims), overstated theoretical contribution, incomplete deployment evidence, etc. R1 recommends 'borderline reject'.

Reviewer 'gVi3' (R2) thinks that the paper is well motivated, proposes a novel method, and obtaines good results. R2 is concerned about missing certain experiments and reporting specifics. R2 recommends 'borderline accept'.

Reviewer 'Nguf' (R3) thinks that the paper is novel and technically sound in its core contribution, well-written and precise in its terminology, and with a clear and well-framed significance. R3 recommends 'accept'.

In sum, the paper has more strengths than weaknesses. The concerns from R1 and R2 are detail-oriented and addressable.

Hence, it is recommended to accept the paper.

Final justification

The paper is reviewed by three experts.

Reviewer 'mRWS' (R1) acknowledges that the paper addresses an important problem (a real deployment bottleneck), proposes a technically coherent method with a sensible design, conducts a broad range of experiments that involve multiple medical VLMs and video VLMs, and provides useful implementation and reproducibility details. R1 is concerned about the main metric, insufficient baseline coverage (for the strongest claims), overstated theoretical contribution, incomplete deployment evidence, etc. R1 recommends 'borderline reject'. After rebuttal, R1 increases the score to 'borderline accept'.

Reviewer 'gVi3' (R2) thinks that the paper is well motivated, proposes a novel method, and obtaines good results. R2 is concerned about missing certain experiments and reporting specifics. R2 recommends 'borderline accept'.

Reviewer 'Nguf' (R3) thinks that the paper is novel and technically sound in its core contribution, well-written and precise in its terminology, and with a clear and well-framed significance. R3 recommends 'accept'.

In sum, the paper has more strengths than weaknesses. The concerns from R1 and R2 are detail-oriented and addressable. These concerns are mostly addressed by the rebuttal.

Hence, it is recommended to accept the paper.

Reviewer NgufOpenReview ↗
Rating
5/6
Confidence
1/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The proposed TACT-KV (Tri-Axis Cosine Transform for KV Cache) method aims to compress the visual KV cache in vision-language models (VLMs), particularly for volumetric inputs like 3D CT scans and videos. The core idea of this approach is - 1. Reshape the visual KV cache into a 3D tensor (slice × height × width), exploiting the spatial structure inherited from the vision encoder, 2. Apply a separable 3D Discrete Cosine Transform (DCT) to move into the frequency domain, 3. Allocate bits across frequency components using a reverse water-filling strategy (more bits to high-energy components, fewer to low-energy ones), 4. Compress with standard quantization.

Main contributions include:

  1. a theoretical proof for distortion gain of water filling algorithm over uniform bit allocation in terms of spectral concentration of the cache
  2. a extensive evaluation covering six medical VLMs, two 3D CT benchmarks, and four general-purpose VLMs on Video-MME, establishing that TACT-KV is the only tested method that remains viable at 1-bit quantization

Main strengths of this approach are - 1. No calibration data is required, 2. No learnable parameters, 3. Runs once for every layer per sequence in single forward pass.. 4. Text token remain in b16, only visual tokens are compressed. 5. The benefit of three-axis structural compression extends beyond medical imaging to video tasks.

Strengths and weaknesses

Quality The paper is technically sound in its core contribution. The pipeline reshape to volumetric grid, apply separable 3D DCT-II, allocate bits via reverse water-filling, quantize with scalar codebooks - is cleanly motivated and well-executed. The theoretical contribution (relating distortion gain to spectral flatness) provides principled grounding, though the authors are appropriately candid that it holds only in the high-rate regime and breaks down on smaller models at the lowest operating points. The evaluation breadth is a clear strength: six medical VLMs spanning 4B–32B parameters, two 3D CT benchmarks from different anatomical regions, and a cross-domain test on Video-MME. The 1-bit survival result is striking and well-supported. The detailed analysis on per-subtype 1 bit results and elaborate reproducibility statement is appreciated. However, I note that the tasks evaluated are primarily classification and QA — generation-heavy tasks (e.g., radiology report writing, detailed spatial localization) are absent, and these may stress the compressed cache differently. Additionally, the compute-memory trade-off is acknowledged but not profiled in detail: the added FLOPs from the codebook and inverse DCT path are mentioned but no wall-clock latency breakdown is provided, making it difficult to judge whether the 8× batch gain translates to proportional throughput improvement or is partially offset by per-token overhead. The comparison with baselines raises a minor fairness question: whether prior methods (designed for full KV caches or text-dominant settings) were applied to only the visual portion under identical conditions. The paper would benefit from a brief explicit statement on this point.

Clarity The paper is well-written and precise in its terminology. The experiments and limitation section is notably well-structured — each limitation is specific, falsifiable, and scoped. One area where clarity could improve: the conclusion states that the margin over 1D quantizers "widens as the input becomes more spatially coherent," which implicitly defines the failure mode (spatially incoherent inputs) without stating it directly. Since noisy low-dose CT and corrupted CTs due to motion are common in clinical practice, making this converse explicit would help practitioners judge applicability.

Significance The practical significance is clear and well-framed. The authors correctly identify that clinical sites typically operate on single-card or small-cluster GPUs, and that the visual KV cache is the dominant memory bottleneck for volumetric inputs. An 8× batch capacity improvement on a single 96 GiB card directly addresses a real deployment constraint. The calibration-free, parameter-free design removes adoption friction - a non-trivial consideration in regulated medical environments where retraining or fine-tuning introduces validation burden. The broader applicability to video (Video-MME) suggests the method is not narrowly specialized, though the authors rightly accept this as empirical rather than predicted by their volumetric motivation. The significance would be further strengthened by demonstrating performance on spatially diverse 3D modalities (MRI, PET) and generation tasks, but these are reasonable future work items and not the gaps that undermine the current contribution.

Originality TACT-KV is original not because it invents new math - DCT, water-filling, and quantization have existed for decades but because it notices something no one else did: the visual KV cache has a natural 3D shape (slices × height × width) that can be exploited for compression. Every prior method treats the cache as either a flat sequence or compresses along a single dimension. TACT-KV is the first to say: "this data came from a 3D volume, so compress it like one." That simple observation, paired with a principled bit allocation strategy instead of ad-hoc frequency truncation, is what makes it novel.

Questions

Have you evaluated TACT-KV on generation-heavy tasks such as radiology report writing or spatial grounding? If not, do you have preliminary evidence that the compressed cache retains sufficient spatial detail for these tasks? The evaluation is limited to binary classification. Do you consider this a fundamental limitation of the method, or simply an evaluation gap? What gives you confidence that 1-bit survival on classification extends to longer, more demanding generation?

Limitations

The authors have been straightforward about the limitations of their work - the theory gap at low rates, single modality validation only, compute trade-off and clincal positioning of this approach are all well described. They have explicitly discouraged the use of this approach as replacement of bf16 in safety critical applications.

Final justification

Thanks for sharing results on generation task like radiology report writing and wall-clock latency breakdown. I will stick to my previous recommendation of accepting the paper

Formatting concerns

The broader impact discussion should be in the main paper rather than supplementary as NeurIPS guideliness expect authors to address the potential societal implications alongside the main contributions.

1 comment
Authors · RebuttalOpenReview ↗
Rebuttal

We appreciate the thorough review and thoughtful feedback on our submission. We are grateful of the statements of "technically sound in its core contribution" and "the practical significance is clear and well-framed". In the following, we have provided a point-by-point response to all questions raised.


Q1: Generation-heavy tasks such as radiology report writing are absent, and the evaluation is limited to binary classification. Is this a fundamental limitation or an evaluation gap, and what gives confidence that 1-bit survival extends to longer generation?

R1: We thank the reviewer for this insightful question. We provide direct evidence on radiology report writing, and address both parts below:

  • We evaluate the report generation task on a 300-volume CT-RATE subset. Table Q1 reports two sets of metrics.

    • BLEU-4, METEOR and ROUGE-L against the bf16 reference measure whether swapping in a compressed cache changes what the deployed system writes. This is the generation analogue of the prediction-flip rate of Table 1.
    • METEOR and ROUGE-L against CT-RATE ground truth are reported for the bf16 reference and for each compressed cache, so a compressed cache is judged relative to the uncompressed one.

    TACT-KV at 1 bit stays close to the bf16 reference and reproduces it token for token on 26% and 35% of volumes, and its agreement with the ground truth is indistinguishable from that of the bf16 reference. KIVI at the same rate retains about half that agreement on MedGemma 1.5 4B and collapses on Hulu-Med 7B.

  • This is an evaluation gap rather than a fundamental limitation. 1-bit survival extends to longer, more demanding generation because the compressed state is fixed at prefill and tokens produced during decoding are stored at bf16, so generation length does not add compression error.

Table Q1: CT-RATE findings generation (N=300 volumes, greedy decoding, 180-token budget). "Identical" is the fraction of volumes whose generation matches the bf16 reference token for token.

VLM Method BLEU-4 (vs bf16) ↑ METEOR (vs bf16) ↑ ROUGE-L (vs bf16) ↑ METEOR (vs ground truth) ↑ ROUGE-L (vs ground truth) ↑ Identical ↑
MedGemma 1.5 4B bf16 (reference) — — — 0.120 0.147 —
TACT-KV (ours), 1-bit 0.622 0.709 0.709 0.123 0.150 26%
KIVI, 1-bit 0.220 0.377 0.386 0.097 0.121 0%
Hulu-Med 7B bf16 (reference) — — — 0.045 0.077 —
TACT-KV (ours), 1-bit 0.545 0.703 0.685 0.048 0.081 35%
KIVI, 1-bit 0.000 0.000 0.000 0.001 0.002 0%

Q2: No wall-clock latency breakdown is provided, so it is unclear whether the 8× batch gain translates to proportional throughput improvement or is partially offset by per-token overhead.

R2: We thank the reviewer for this point. As requested, we provide wall-clock latency and throughput at the operating points of Table 6.

  • Table Q2(a) reports decoding throughput at the maximum batch sizes. The batch capacity does not translate proportionally. The decode step lengthens as the batch grows, so the eight-fold batch gain on Hulu-Med 32B yields 2.02 times the aggregate throughput of the bf16 cache, and the gain across the three models is 1.2 to 2.0 times.
  • Table Q2(b) isolates the per-token overhead at a fixed batch. Run at the largest batch the bf16 cache sustains, the TACT-KV decode step is 1.1 to 1.45 times faster, since the compressed cache streams 6.9 to 7.6 times fewer bytes per step. The reconstruction cost therefore does not offset the gain at these batch sizes.

Table Q2(a): decoding throughput at the maximum batch sizes of Table 6.

Model B (bf16 → TACT-KV) Decode step (ms) Throughput (tok/s) ↑ Ratio ↑
Hulu-Med 4B 32 → 128 165 → 467 194 → 274 1.42×
Hulu-Med 7B 64 → 400 136 → 723 472 → 553 1.17×
Hulu-Med 32B 8 → 64 121 → 481 66 → 133 2.02×

Table Q2(b): decode step latency at the maximum batch size of bf16.

Model B bf16 decode step (ms) ↓ TACT-KV decode step (ms) ↓ Speed-up ↑
Hulu-Med 4B 32 165 114 1.45×
Hulu-Med 7B 64 136 119 1.14×
Hulu-Med 32B 8 121 110 1.10×

Q3: State explicitly whether prior methods were applied to only the visual portion under identical conditions.

R3: Thanks for pointing out this fairness concern. We confirm that in our study prior methods were " applied to only the visual portion under identical conditions". Every backend compresses the visual portion of the cache only and holds the non-visual tokens at bf16. The shared visual prefix is prefilled once and reused across methods, and the slice budget, preprocessing and prompt are the same for every method and every bit budget, so the quantization step is the only factor that differs between them (Appendix C.2). We will state this explicitly in the main text.


Q4: The conclusion implies the failure mode without stating it. Make the converse explicit, since noisy low-dose CT and motion-corrupted CT are common in clinical practice.

R4: We thank the reviewer for pointing this out, and we provide more explicit clarification:

  • We will make this converse explicit. The advantage of TACT-KV is reduced on spatially incoherent inputs such as noisy low-dose CT and volumes corrupted by motion.
  • This can be explained by Theorem 1. The gain of reverse water-filling over uniform allocation is 1/γ, where γ is the spectral flatness of the transformed cache. A spatially coherent volume concentrates the cache energy in a few low-frequency components, so γ is small and 1/γ is large. Noise and motion spread that energy across the spectrum, γ approaches 1, and the gain approaches unity.

Formatting Concerns: The broader impact discussion should be in the main paper rather than supplementary as NeurIPS guidelines expect authors to address the potential societal implications alongside the main contributions.

We thank the reviewer for pointing this out. We will move the broader impact discussion from Appendix H into Section 4, alongside the limitations already stated there.

Reviewer gVi3OpenReview ↗
Rating
4/6
Confidence
3/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper proposes TACT-KV, a calibration-free method motivated by the high similarity of spatial neighbors to compress 3D scans along all three anatomical axes. TACT-KV reshapes the visual cache into a 3D grid, applies cosine transform along three spatial, and allocates more storage bits to high-energy components. Experiments prove that TACT-KV preserves prediction fidelity better than existing baselines on 6 medical VLMs and 2 3D CT benchmarks.

Strengths and weaknesses

Strength:

  1. The paper is well-motivated by pointing out that 3D scans exhibits strong spatial correlations across all three anatomical axes and establish the method from this motivation.
  2. TACT-KV proposes a novel method for compressing 3D KV Cache by combining cosine transform, reverse water-filling bit allocation, and gain-shape codebook encoding to compress 3D scans along all three anatomical axes and allocates more storage to more significant tokens.
  3. The method requires no calibration or training and demonstrates strong results at 1-bit compression. Weakness:
  4. The paper did not report the inference speed per scan, which is important to measure how much computation is added.
  5. There is a lack of comparison with simply feeding the model with fewer slices or less tokens.
  6. As shown in Table 15-20, AUROC on CT-RATE remains low around 50%. When the baseline model performs poorly like random guessing, it seems less persuasive to demonstrate that the compression method keeps the performance , which is still random.
Questions

See weaknesses

Limitations

yes

Final justification

My concerns have been addressed in the author's rebuttal. I will maintain my score and remain on the acceptance side.

Formatting concerns

No formatting concerns.

3 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We would like to thank you for recognizing the strengths of our paper: that it is "well-motivated" by the "strong spatial correlations across all three anatomical axes", and that TACT-KV "proposes a novel method for compressing 3D KV Cache". Below, we have provided a point-by-point response to all your concerns.


W4: Report the inference speed per scan, which measures how much computation TACT-KV adds.

R4: We provide the per-scan measurement, together with the batched operating points at which the added computation is recovered. All numbers are taken on the paper's hardware at S = 60 slices.

  • Table R4(a) gives the per-scan cost at B = 1, prefill plus a 64-token greedy continuation, as mean ± std over 10 CT-RATE validation volumes. The added computation splits in two. The one-time compression at prefill costs +0.30 s to +0.77 s across model scales and does not grow with the generation length. The per-token reconstruction at decode costs +0.24 s to +0.66 s over a 64-token report.
  • Table R4(b) places the same cost at the batch sizes the method targets. Decoding there is bandwidth-bound and the compressed cache streams 6.9 to 7.6 times fewer bytes per step, so at equal HBM the aggregate throughput reaches 1.2 to 2.0 times that of the bf16 cache.
  • Table R4(c) isolates the overhead at a fixed batch size. Run at the largest batch the bf16 cache sustains, the TACT-KV decode step is 1.1 to 1.45 times faster, so the cost visible at B = 1 has inverted at these batch sizes.

Table R4(a): inference speed per scan at B = 1. Parenthesized values are the computation TACT-KV adds over the bf16 cache.

Model Mode Prefill (s) Decode 64 tok (s) Per-scan (s) Per-token (ms)
Hulu-Med 4B bf16 0.87 ± 0.004 1.05 ± 0.008 1.92 ± 0.01 16.4
TACT-KV 1-bit 1.41 ± 0.06 (+0.54) 1.70 ± 0.01 (+0.66) 3.11 ± 0.06 (+1.20) 25.2
Hulu-Med 7B bf16 0.97 ± 0.001 0.97 ± 0.01 1.95 ± 0.01 15.2
TACT-KV 1-bit 1.28 ± 0.02 (+0.30) 1.21 ± 0.004 (+0.24) 2.49 ± 0.02 (+0.54) 17.9
Hulu-Med 32B bf16 3.66 ± 0.02 3.65 ± 0.002 7.31 ± 0.02 57.0
TACT-KV 1-bit 4.43 ± 0.01 (+0.77) 4.13 ± 0.007 (+0.48) 8.55 ± 0.008 (+1.25) 62.3

Table R4(b): decoding throughput at the maximum batch sizes of Table 6.

Model B (bf16 → TACT-KV) Decode step (ms) Throughput (tok/s) Ratio
Hulu-Med 4B 32 → 128 165 → 467 194 → 274 1.42×
Hulu-Med 7B 64 → 400 136 → 723 472 → 553 1.17×
Hulu-Med 32B 8 → 64 121 → 481 66 → 133 2.02×

Table R4(c): decode step latency at the maximum batch size of bf16.

Model B bf16 decode step (ms) TACT-KV decode step (ms) Speed-up
Hulu-Med 4B 32 165 114 1.45×
Hulu-Med 7B 64 136 119 1.14×
Hulu-Med 32B 8 121 110 1.10×

W5: There is a lack of comparison with simply feeding the model with fewer slices or less tokens.

R5: As requested, we provide a baseline that simply feeds the model with fewer slices. For each VLM and dataset, the bf16 slice budget is lowered to the tightest setting whose measured visual cache still matches or exceeds TACT-KV's 1-bit footprint, and its flip rate is calculated against the same bf16 reference under the protocol of Table 1.

  • For the MedGemma variants, 3 slices on RSNA-ICH and 8 slices on CT-RATE bring the bf16 cache down to TACT-KV's 1-bit footprint, against the 60 and 85 slices of the paper.
  • For the Hulu-Med variants, the cache does not scale with the slice count, and even 2 slices at bf16 still exceed TACT-KV's 1-bit footprint by 2.0 to 2.2 times on RSNA-ICH and by 4.1 to 4.4 times on CT-RATE.

Table R5: macro prediction-flip rate (%) against the bf16 reference, with the reduced slice budget in parentheses.

VLM RSNA-ICH bf16, fewer slices RSNA-ICH TACT-KV 1-bit CT-RATE bf16, fewer slices CT-RATE TACT-KV 1-bit
MedGemma 1.5 4B 13.28±0.50 (3) 3.78±0.28 10.22±0.25 (8) 4.69±0.18
MedGemma 4B 19.73±0.58 (3) 2.37±0.22 11.20±0.26 (8) 2.95±0.14
MedGemma 27B 5.72±0.34 (3) 0.37±0.09 8.25±0.23 (8) 2.63±0.13
Hulu-Med 7B 13.28±0.50 (2) 6.08±0.35 28.17±0.38 (2) 10.44±0.26
Hulu-Med 4B 11.73±0.47 (2) 8.53±0.41 23.74±0.36 (2) 7.22±0.22
Hulu-Med 32B 24.45±0.63 (2) 9.13±0.42 25.67±0.37 (2) 10.04±0.25

Simply feeding the model with fewer slices degrades prediction fidelity on all twelve VLM-dataset pairs, at a cache footprint no smaller than TACT-KV's. Reducing the input is therefore not a substitute for compressing the cache.


W6: CT-RATE AUROC remains around 50%, so preserving a reference close to random guessing is less persuasive.

R6: We thank the reviewer for raising this point and clarify it as follows.

  • The low CT-RATE AUROC originates in the reference models rather than in our evaluation. We score the assertion prompt that CT-CLIP selected for CT-RATE zero-shot detection [2] and query the 18 abnormalities independently over a slice sequence carrying SLICE index markers, which is the protocol MedGemma reports for this dataset [1]. The bf16 reference and every compressed variant receive the identical input, prompt and preprocessing, so no method is advantaged by the protocol.
  • Volumetric CT understanding is an open problem for current medical VLMs. MedGemma's own technical report gives a macro F1 of 26.9 on CT-RATE for MedGemma 1.5 4B [1], and an independent benchmark of eight 3D medical VLMs reports "severe degradation on semantic-spatial reasoning tasks, averaging 34% accuracy and often below random" [3]. Our fidelity claim therefore rests on RSNA-ICH, where the bf16 reference reaches 0.601 to 0.833 macro AUROC and TACT-KV tracks it within the 95% confidence band on all six VLMs (Figure 4). On CT-RATE we report the flip rate as consistency with the deployed reference.

References

[1] Sellergren et al. MedGemma 1.5 Technical Report. arXiv 2026.

[2] Hamamci et al. Generalist foundation models for 3D CT. Nature BME 2026.

[3] Monon et al. Lost in Volume: The CT-SpatialVQA Benchmark for Evaluating Semantic-Spatial Understanding of 3D Medical Vision-Language Models. arXiv 2026.

Reviewer gVi3 · CommentOpenReview ↗

Official Comment

Thanks for the detailed rebuttal. Most of my concerns have been addressed. I will maintain my score and remain on the acceptance side.

Authors · CommentOpenReview ↗

Reply to official comment

Dear Reviewer gVi3,

Many thanks for your feedback and for the time you have taken to engage with our work. We are glad that most of your concerns have been resolved, and we are happy to provide any further clarification that would be helpful.

Best regards,

The TACT-KV team

Reviewer mRWSOpenReview ↗
Rating
4/6
Confidence
3/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The paper proposes TACT-KV, a calibration-free compression pipeline for the visual KV cache of volumetric medical vision-language models. The method reshapes the visual KV cache into a slice-height-width tensor, applies a separable 3D DCT, allocates a layer-wise bit budget across frequency bins using reverse water-filling, and encodes the retained coefficients with a gain-shape scalar quantizer. The evaluation covers two CT benchmarks, six medical VLMs, and a Video-MME transfer experiment with four general-purpose VLMs. The reported 1-bit results are strong relative to the evaluated baselines, and the idea of exploiting the volumetric token layout is natural and potentially useful.

Strengths and weaknesses

Strengths

  1. The problem is important. Volumetric medical VLMs can produce very long visual contexts, and visual KV cache memory is a real deployment bottleneck.

  2. The method is technically coherent. Treating the visual cache as a structured 3D tensor and applying transform coding is a sensible design, especially for CT volumes where neighboring slices and neighboring in-plane tokens are highly correlated.

  3. The experimental coverage is broader than usual for this topic. The paper evaluates multiple medical VLMs, two CT datasets, and also tests whether the same idea transfers to video VLMs.

  4. The appendices contain useful implementation and reproducibility details, including per-model preprocessing, compute cost, and a fused inverse-DCT attention path.

Main comments

  1. The main metric does not fully support the clinical-fidelity framing. The paper uses prediction-flip rate relative to the bf16 reference as the primary metric. This is a useful measure of behavioral consistency, but it does not show that the compressed system preserves diagnostic correctness. This distinction matters because some bf16 references appear weak on CT-RATE under the reported rank-classification protocol. Preserving a weak decision boundary is not the same as preserving clinical fidelity. The main claims should be reframed around output consistency unless the authors add stronger ground-truth metrics such as AUROC, AUPRC, F1, calibration error, or task loss as primary evidence.

  2. The baseline coverage is not sufficient for the strongest claims. The main tables compare against KIVI, TurboQuant, VidKV [4], and AKVQ-VL, but several highly relevant KV-cache or multimodal-cache methods are discussed only in related work or omitted from the main comparison. In particular, KVQuant [1], VL-Cache [2], and FlashCache [3] are directly relevant to the paper’s claims. In addition, frequency-domain or transform-coding baselines such as FreqKV [5], KVTC [6], and Fourier-VLM [7] are important reference points for separating the contribution of the 3D volumetric prior from the more general benefit of transform-domain compression. Axis-count ablations are informative, but they are not a substitute for implementing or carefully justifying the exclusion of complete baselines. The statement that TACT-KV is the only method that survives the 1-bit regime should be narrowed to the evaluated baselines unless these comparisons are added.

  3. The theoretical contribution is overstated relative to the operating regime. The reverse-water-filling result is derived under a high-rate Gaussian scalar-quantization model, a continuous-bit relaxation, and an all-active-bin assumption. The main empirical regime, however, is 1-bit compression, where these assumptions are explicitly violated. Several closure checks deviate very substantially from the closed-form prediction. I therefore view the theorem as a useful explanatory heuristic rather than a strong theoretical justification for the reported 1-bit behavior. The authors should either evaluate the closure in higher-bit regimes where the assumptions are more plausible or derive a low-rate active-set version of the result.

  4. The deployment evidence is incomplete. The paper reports maximum batch size under an equal-HBM constraint and per-request cache size, but not actual decoding throughput, latency, or tokens per second. This is important because TACT-KV introduces dequantization, inverse 3D DCT, and gain-shape decoding overhead. A larger batch that fits in memory does not necessarily imply better serving throughput. The fused path also appears to be implemented and profiled only for the Hulu-Med/Qwen2 attention setting, while transfer to other attention implementations is described more as a principle than a demonstrated implementation. The deployment claim should be narrowed or supported by wall-clock serving measurements.

  5. The attribution to the three-axis volumetric prior is not fully isolated. TACT-KV combines a 3D transform, adaptive bit allocation, and a strong gain-shape quantizer. The current ablations are helpful, but they do not fully separate these factors. A cleaner ablation should include no-transform plus the same water-filling and quantizer, 3D DCT with uniform allocation, and the full TACT-KV pipeline under matched actual memory budgets. This would make it clearer whether the gain primarily comes from volumetric decorrelation, adaptive bit allocation, or the quantizer backend.

References

[1] Hooper et al. “KVQuant: Towards 10 Million Context Length LLM Inference with KV Cache Quantization.” NeurIPS 2024.

[2] Tu et al. “VL-Cache: Sparsity and Modality-Aware KV Cache Compression for Vision-Language Model Inference Acceleration.” ICLR 2025.

[3] Yang et al. “Revisiting Multimodal KV Cache Compression: A Frequency-Domain-Guided Outlier-KV-Aware Approach.” CVPR 2026.

[4] Tao et al. “Plug-and-Play 1.x-Bit KV Cache Quantization for Video Large Language Models.” arXiv preprint arXiv:2503.16257, 2025.

[5] Kai et al. “FreqKV: Key-Value Compression in Frequency Domain for Context Window Extension.” ICLR 2026.

[6] Staniszewski et al. “KV Cache Transform Coding for Compact Storage in LLM Inference.” ICLR 2026.

[7] Wang et al. “Fourier-VLM: Compressing Vision Tokens in the Frequency Domain for Large Vision-Language Models.” arXiv preprint arXiv:2508.06038, 2025.

Questions
  1. What are the ground-truth task metrics for each compressed method, not only flip rate relative to bf16?

  2. How is the actual memory budget computed for TACT-KV, including the fp32 gain scalar, index overhead, and any metadata? Are the baselines matched by nominal bits or by true cache footprint?

  3. Why were KVQuant [1], VL-Cache [2], FlashCache [3], FreqKV [5], KVTC [6], and Fourier-VLM [7] not included in the main comparison, or at least discussed as non-comparable baselines with explicit reasons?

  4. What are the end-to-end decode latency and throughput numbers at the reported maximum batch sizes?

Limitations

yes

Final justification

The rebuttal resolved most of my substantive concerns:

  1. The authors added strong missing baselines, matched-memory ablations, higher-bit validation of the theoretical analysis, and wall-clock latency/throughput measurements. These additions substantially strengthen both the empirical evidence and the deployment claims.

  2. The authors also clarified that CT-RATE mainly measures consistency with the bf16 reference, while RSNA-ICH provides stronger evidence of preserved diagnostic performance. The added report-generation experiment further broadens the evaluation.

  3. Two minor issues remain: the superiority claim should be narrowed because VL-Cache and FlashCache are competitive on some MedGemma settings, and the paper should clearly distinguish the nominal 1-bit payload from the full effective cache footprint.

Considering that the remaining issues concern claim precision rather than the validity of the method, and taking into account the positive assessments from the other reviewers and the AC, I raise my score from 3 to 4 (Borderline Accept).

Formatting concerns

N/A

3 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We sincerely thank the reviewer for the thorough review and valuable feedback, which significantly improved the work. We provide the following point-by-point response:


W1Q1: Report ground-truth task metrics for each compressed method, and the bf16 reference appears weak on CT-RATE

R1: Thanks. We would like to clarify the metrics used in our paper.

  • The ground-truth task metric we report is macro AUROC. Figure 4 reports macro-averaged ROC curves at 1-bit across six medical VLMs on RSNA-ICH, against the bf16 reference with 95% bootstrap CIs (1,000 resamples). TACT-KV tracks the bf16 reference inside its confidence band on all six VLMs, while the baseline curves drift outside the band on the Hulu-Med variants. Additionally, Appendix Tables 9 to 20 directly provide per-label AUROC for each compressed method on both RSNA-ICH and CT-RATE, with the bf16 column included as the uncompressed reference.

  • Why do some bf16 references appear weak on CT-RATE? We follow the protocols published for this benchmark, the 18 independent abnormality queries of MedGemma's own CT-RATE evaluation [1] and the assertion prompt CT-CLIP selected for CT-RATE zero-shot detection [2]. Under this setting, MedGemma's technical report gives a macro F1 of 26.9 for MedGemma 1.5 4B [1]. Volumetric abnormality classification is an open problem for generalist medical VLMs rather than a property of our evaluation, and every method is scored against the same reference.


W2Q3: Implement the six named baselines or justify their exclusion with explicit reasons, and narrow the 1-bit claim.

R2: Thanks. Following this request, we added KVQuant [3], VL-Cache [4], FlashCache [5], and KVTC [6] as head-to-head baselines, and we exclude FreqKV [7] and Fourier-VLM [8], with the following clarifications.

  • FreqKV requires training, and its compression is triggered by cache overflow, which does not occur under a single fixed-length prefill. Fourier-VLM applies its transform to the vision encoder output before the decoder, so it does not modify the per-layer KV cache, and it requires training. Therefore, it doesn’t serve as a viable baseline.

  • The rest are evaluated at the footprint TACT-KV occupies at 1-bit.

    • VL-Cache and FlashCache are eviction-based rather than quantization-based and admit no bit-width axis, so the footprint is the only common operating point.
    • KVQuant and KVTC are quantization-based and are the closest counterparts to the baselines of Table 1, while they require calibration. Every baseline in Table 1, and TACT-KV itself, is calibration-free.

Table R2: additional baselines on RSNA-ICH, macro flip rate (%).

VLM TACT-KV KVQuant KVTC VL-Cache FlashCache
MedGemma 1.5 4B 3.78±0.28 9.19±0.42 16.39±0.54 2.77±0.24 8.27±0.40
MedGemma 4B 2.37±0.22 10.58±0.45 63.07±0.71 2.17±0.21 7.77±0.39
MedGemma 27B 0.37±0.09 20.75±0.59 10.28±0.44 0.33±0.08 0.23±0.07
Hulu-Med 7B 6.08±0.35 8.29±0.40 13.92±0.51 13.49±0.50 14.01±0.51
Hulu-Med 4B 8.53±0.41 28.85±0.66 78.39±0.60 10.30±0.44 8.84±0.41
Hulu-Med 32B 9.13±0.42 11.30±0.46 19.71±0.58 11.70±0.47 8.85±0.41

Analysis. The two eviction methods (VL-Cache and FlashCache) are competitive on the MedGemma variants, and this advantage does not carry over to the Hulu-Med variants. The MedGemma backbone compresses only its full-attention layers and holds the sliding-window layers at bf16 (Appendix C.2), whereas Hulu-Med marks every layer full-attention. Eviction removes a fraction of the KV entries at every compressed layer and the removed entries cannot be recovered, while quantization retains every entry at a bounded error, so the loss accumulates with the number of compressed layers. Against the two quantization methods (KVQuant and KVTC) TACT-KV attains the lower flip rate on all six VLMs.

We will adjust the wording as requested and state the claim as TACT-KV is the only method that survives 1-bit quantization.


W3: The theorem's assumptions are explicitly violated at 1-bit, so evaluate the closure in higher-bit regimes.

R3: Thanks. As requested, we evaluated the closure in the higher-bit regimes of 2-bit and 4-bit. Bold marks closure within 30% of 1/γ_K, italic within 50%.

Table R3: measured D_uniform/D_water-fill on the visual K cache against the prediction 1/γ_K.

VLM RSNA 1/γ_K RSNA 2-bit RSNA 4-bit CT-RATE 1/γ_K CT-RATE 2-bit CT-RATE 4-bit
MedGemma 1.5 4B 3.58× 2.97× 2.65× 5.85× 8.76× 7.02×
MedGemma 4B 3.06× 2.84× 2.45× 5.00× 7.05× 5.80×
MedGemma 27B 3.77× 2.82× 2.61× 5.56× 6.08× 5.42×
Hulu-Med 7B 4.85× 4.01× 3.61× 7.58× 10.35× 8.45×
Hulu-Med 4B 3.95× 3.23× 3.04× 6.17× 9.01× 7.99×
Hulu-Med 32B 4.46× 3.75× 3.36× 6.58× 7.51× 6.43×

Closure holds within 30% on eight of twelve pairs at 2-bit and eleven at 4-bit, the rest within 50%. The closed form therefore predicts the allocation gain in the regime in which it is derived, which is the role Theorem 1 plays in the paper.


W4Q4: Wall-clock decoding throughput and latency at the reported maximum batch sizes, and the fused path beyond Hulu-Med/Qwen2.

R4: Thanks. As requested, we added wall-clock decoding throughput and latency.

  • Table R4(a) reports throughput and decode latency at the maximum batch sizes of Table 6. TACT-KV attains 1.2 to 2.0 times the aggregate decoding throughput of the bf16 cache.
  • Table R4(b) reports the decode step at the maximum batch size of bf16, where TACT-KV is 1.1 to 1.45 times faster.
  • On the fused path implementation, the Hulu-Med family already spans two attention classes, Qwen2 on 7B and 32B and Qwen3 on 4B (Appendix C.2), and we additionally implement Gemma-3, reported as the MedGemma 27B row of both tables. Each class is verified against the reference decode.

Table R4(a): decoding throughput and latency at the maximum batch sizes of Table 6.

Model B (bf16 → TACT-KV) Decode step (ms) Throughput (tok/s) Ratio
Hulu-Med 4B 32 → 128 165 → 467 194 → 274 1.42×
Hulu-Med 7B 64 → 400 136 → 723 472 → 553 1.17×
Hulu-Med 32B 8 → 64 121 → 481 66 → 133 2.02×
MedGemma 27B* 24 → 64 164 → 239 147 → 268 1.83×

*MedGemma 27B is not in Table 6. It is a second attention architecture measured under the same protocol.

Table R4(b): decode step latency at the maximum batch size of bf16.

Model B bf16 decode step (ms) TACT-KV decode step (ms) Speed-up
Hulu-Med 4B 32 165 114 1.45×
Hulu-Med 7B 64 136 119 1.14×
Hulu-Med 32B 8 121 110 1.10×
MedGemma 27B 24 164 119 1.38×

W5: A cleaner ablation with no-transform and with uniform allocation, under matched actual memory budgets.

R5: As requested, we provide two additional comparisons, (i) no transform with the same water-filling and gain-shape quantizer, and (ii) 3-D DCT with uniform allocation, under matched memory.

Table R5: attribution of the transform and the bit allocation, macro prediction-flip rate (%) on RSNA-ICH at 1-bit average rate.

VLM (i) no transform + water-filling (ii) 3-D DCT + uniform allocation TACT-KV
MedGemma 1.5 4B 6.61 9.97 3.78
MedGemma 4B 4.42 12.29 2.37
MedGemma 27B 4.83 3.05 0.37
Hulu-Med 7B 42.20 25.76 6.08
Hulu-Med 4B 76.57 58.79 8.53
Hulu-Med 32B 22.04 23.89 9.13

TACT-KV achieves the lowest flip rate on all six VLMs. Both controls retain the gain-shape quantizer and both degrade substantially, so the volumetric transform and the adaptive allocation are each necessary and the gain does not rest on the quantizer backend.


Q2: How the memory budget is computed, and whether baselines are matched by nominal bits or true cache footprint.

R6:

  • How is the actual memory budget computed for TACT-KV? The nominal rate fixes the payload only. Everything else is metadata, itemized in Table Q2 on a CT-RATE validation study. At nominal 1-bit the complete state is 1.47 bits per element.

Table Q2: complete footprint of TACT-KV at nominal 1-bit on one CT-RATE study (Hulu-Med 7B, S = 60, bf16 cache 903 MB).

Component Size (MB) Equivalent bits per element
Quantized payload 55.1 1.00 (by construction)
fp32 gain scalars 11.9 0.22
Positions and bit-allocation maps, stored once per layer 13.8 0.25 at B = 1, → 0 as B grows
Text tokens at bf16 22.5 outside the visual budget
Total 103.3 1.47
  • Are the baselines matched by nominal bits or by true cache footprint? The accuracy tables are matched by nominal payload bits per element, the convention of this literature. KIVI, TurboQuant and VidKV all report bit-widths that exclude their own metadata, such as per-group zero points and scales, per-vector L2 norms, and fp16 residual windows. We follow the same convention and apply it identically across all compression backends.

References

[1] Sellergren et al. MedGemma 1.5 Technical Report. arXiv 2026

[2] Hamamci et al. Generalist foundation models for 3D CT. Nature BME 2026

[3] Hooper et al. KVQuant. NeurIPS 2024.

[4] Tu et al. VL-Cache. ICLR 2025.

[5] Yang et al. Revisiting Multimodal KV Cache Compression. CVPR 2026.

[6] Staniszewski et al. KV Cache Transform Coding. ICLR 2026.

[7] Kai et al. FreqKV. ICLR 2026.

[8] Wang et al. Fourier-VLM. arXiv 2025.

Reviewer mRWS · CommentOpenReview ↗

Thank you for the detailed rebuttal. The additional baselines, higher-bit theoretical validation, matched-memory ablations, and wall-clock measurements have addressed most of my concerns.

I only suggest that the final version narrow the superiority claim, since VL-Cache and FlashCache remain competitive on several MedGemma settings, and clearly distinguish the nominal 1-bit payload from the full effective cache footprint.

Overall, the remaining issues mainly concern claim precision rather than the validity of the method. I therefore raise my score from 3 to 4.

Authors · CommentOpenReview ↗

Reply to official comment

Dear Reviewer mRWS,

We greatly appreciate your thorough review and your careful consideration of our responses. We are glad that the additional baselines, the higher-bit validation, the matched-memory ablations and the wall-clock measurements have addressed most of your concerns.

We confirm that both remaining suggestions will be incorporated in the final version.

  • We will narrow the superiority claim, stating the 1-bit result over the evaluated baselines and separating the comparison against quantization-based methods from the eviction-based ones.
  • We will also distinguish the nominal 1-bit payload from the full effective cache footprint. We will state explicitly that the baselines are matched on the nominal payload, which excludes metadata and is applied identically to every backend, and we will report our own metadata in the effective footprint.

Best regards,

The TACT-KV team

Comments on the paper

1 comment
Authors · CommentOpenReview ↗

Rebuttal Summary

Dear Reviewers, ACs, and PCs,

We sincerely thank all three reviewers for their careful and constructive feedback, and the AC for the clear summary of the reviews. The remaining concerns were detail-oriented, and we summarise our rebuttal for the key concerns below:

  • Regarding deployment evidence (Reviewer mRWS W4Q4, Reviewer gVi3 W4, Reviewer Nguf Q2): We provide wall-clock decoding throughput and per-step decode latency at the maximum batch sizes of Table 6. We further report the decode step latency of both the bf16 and the TACT-KV 1-bit cache at the maximum batch size of bf16. We also report the per-scan prefill and decode cost at batch size 1.

  • Regarding additional baselines (Reviewer mRWS W2Q3, Reviewer gVi3 W5): We added KVQuant, VL-Cache, FlashCache and KVTC across all six medical VLMs at TACT-KV's 1-bit cache footprint, together with a baseline that simply feeds the model fewer slices at the same footprint, and we give explicit reasons for excluding FreqKV and Fourier-VLM.

  • Regarding the main metric (Reviewer mRWS W1Q1): We clarify that beyond the prediction-flip rate, the ground-truth metric we report for diagnostic correctness is macro AUROC. It is given in Figure 4 across all six medical VLMs on RSNA-ICH against the bf16 reference, and per label for every method on both datasets in Appendix Tables 9 to 20.

  • Regarding the theoretical contribution (Reviewer mRWS W3): We evaluated the closure of the closed form in the higher-bit regimes of 2-bit and 4-bit across all twelve VLM-dataset pairs, where it holds within 30% on eight of twelve pairs at 2-bit and eleven of twelve at 4-bit. The closed form therefore predicts the allocation gain in the regime in which it is derived, which is the role Theorem 1 plays in the paper.

We thank the reviewers again for their engagement, which has substantially improved the paper. All new measurements were produced during the rebuttal under the same protocols as the submitted results, and will be integrated into the revised manuscript.

Best regards,

The TACT-KV team

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Missing a submission?

Loading the discussion…