Severity-Controlled Prediction Sets for Medication Recommendation
Yu Gu, Zijun Yu, Chi-Kuang Yeh, Xinyu Wang, Ziyang Song
NeurIPS 2026
TL;DR. We introduce Conformal Severity Control (CSC), a framework that calibrates prediction sets by controlling the mismatch severity of prediction errors.
Abstract. Medication recommendation is a multi-label prediction task. However, existing prediction-set evaluation and calibration methods rely mainly on exact-overlap metrics and therefore treat all missed medications as equally severe, overlooking how closely the prediction set matches them within the medication hierarchy. To address this, we introduce Conformal Severity Control (CSC), a post-hoc framework for calibrating medication prediction sets under hierarchy-aware mismatch severity. CSC uses the Anatomical Therapeutic Chemical (ATC) hierarchy to quantify mismatch severity and controls patient-level severity without retraining the predictor, supporting both average severity and upper-quantile severity for the highest-severity mismatches. Experiments on MIMIC-IV show that CSC tracks user-specified severity tolerances and shifts prediction sets away from distant mismatches toward exact or close matches.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:50 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
Summary
This paper introduces Conformal Severity Control (CSC), a post-hoc calibration framework for medication recommendation that measures prediction errors using an ATC hierarchy-based severity score, assigning larger penalties to clinically distant medication mismatches. CSC learns a single global threshold through conformal risk control to guarantee that the expected severity of prediction errors remains below a user-specified tolerance, and demonstrates its effectiveness on MIMIC-IV using an LLM-based drug recommender.
Strengths
-
CSC addresses a key limitation of exact-match metrics by incorporating ATC hierarchy-based mismatch severity, distinguishing therapeutically similar errors from clinically distant ones.
-
The method is theoretically grounded through conformal risk control, provides severity guarantees, and can be applied post hoc without retraining, making it computationally efficient and easy to integrate with existing recommenders.
-
CSC produces adaptive patient-specific prediction sets that outperform fixed Top-k approaches in flexibility, and the severity-aware calibration framework could generalize to other hierarchical multi-label prediction problems.
Critical concerns that would preclude publication if they are correct
-
gJP6: Unvalidated severity proxy.
-
kWLx: W3 ATC proximity is not necessarily a valid proxy for clinical error severity or drug substitutability.
-
vVjX: Severity was not directly analyzed, but only distances in the hierarchy was considered as severity metric. This is a very simplifying assumption.
Major concerns to address during rebuttal and discussion
-
gJP6: Weak separation from baselines.
-
gJP6: Severity control is close to a size/recall reparametrization.
-
gJP6: Narrow evaluation.
-
gJP6: Can you show a regime where CSC beats the matched baselines it currently ties?
-
gJP6: At a fixed prediction-set size, do CSC sets have lower ATC severity than size-matched recall-optimized sets?
-
gJP6: Can you add a second predictor (a non-LLM recommender) and/or a second dataset, and reconcile the "across datasets" wording in App. C.3 with the single-dataset setup?
-
gJP6: Since each β is calibrated separately, can you disentangle the objective from re-calibration in Fig. 4b (e.g., evaluate upper-quantile severity under a fixed λ across β)?
-
kWLx: W1, W2, W4 and W5
-
vVjX: The empirical evaluation is relatively narrow.
Other concerns
- See also other concerns from three reviewers.
Final justification
I have read the authors’ response and the reviewer discussion. The rebuttal satisfactorily addressed several technical concerns through clarifications, corrections, and additional experiments. One reviewer has raised their score. Some concerns remain regarding the interpretation of ATC distance as a surrogate for clinical severity, the novelty of the contribution, and limitations of the ATC hierarchy.
My decision is based solely on the written reviews, author response, and reviewer discussion. I agree that the severity-related claims should be interpreted cautiously. But I feel the authors have properly narrowed their claims and demonstrated the technical soundness and practical relevance of the approach. Overall, the paper provides a valuable contribution, despite the remaining limitations.
Read meta-review
Meta-review
Summary
This paper introduces Conformal Severity Control (CSC), a post-hoc calibration framework for medication recommendation that measures prediction errors using an ATC hierarchy-based severity score, assigning larger penalties to clinically distant medication mismatches. CSC learns a single global threshold through conformal risk control to guarantee that the expected severity of prediction errors remains below a user-specified tolerance, and demonstrates its effectiveness on MIMIC-IV using an LLM-based drug recommender.
Strengths
-
CSC addresses a key limitation of exact-match metrics by incorporating ATC hierarchy-based mismatch severity, distinguishing therapeutically similar errors from clinically distant ones.
-
The method is theoretically grounded through conformal risk control, provides severity guarantees, and can be applied post hoc without retraining, making it computationally efficient and easy to integrate with existing recommenders.
-
CSC produces adaptive patient-specific prediction sets that outperform fixed Top-k approaches in flexibility, and the severity-aware calibration framework could generalize to other hierarchical multi-label prediction problems.
Critical concerns that would preclude publication if they are correct
-
gJP6: Unvalidated severity proxy.
-
kWLx: W3 ATC proximity is not necessarily a valid proxy for clinical error severity or drug substitutability.
-
vVjX: Severity was not directly analyzed, but only distances in the hierarchy was considered as severity metric. This is a very simplifying assumption.
Major concerns to address during rebuttal and discussion
-
gJP6: Weak separation from baselines.
-
gJP6: Severity control is close to a size/recall reparametrization.
-
gJP6: Narrow evaluation.
-
gJP6: Can you show a regime where CSC beats the matched baselines it currently ties?
-
gJP6: At a fixed prediction-set size, do CSC sets have lower ATC severity than size-matched recall-optimized sets?
-
gJP6: Can you add a second predictor (a non-LLM recommender) and/or a second dataset, and reconcile the "across datasets" wording in App. C.3 with the single-dataset setup?
-
gJP6: Since each β is calibrated separately, can you disentangle the objective from re-calibration in Fig. 4b (e.g., evaluate upper-quantile severity under a fixed λ across β)?
-
kWLx: W1, W2, W4 and W5
-
vVjX: The empirical evaluation is relatively narrow.
Other concerns
- See also other concerns from three reviewers.
Final justification
I have read the authors’ response and the reviewer discussion. The rebuttal satisfactorily addressed several technical concerns through clarifications, corrections, and additional experiments. One reviewer has raised their score. Some concerns remain regarding the interpretation of ATC distance as a surrogate for clinical severity, the novelty of the contribution, and limitations of the ATC hierarchy.
My decision is based solely on the written reviews, author response, and reviewer discussion. I agree that the severity-related claims should be interpreted cautiously. But I feel the authors have properly narrowed their claims and demonstrated the technical soundness and practical relevance of the approach. Overall, the paper provides a valuable contribution, despite the remaining limitations.
1 comment
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 4/4
- Clarity
- 4/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- use_inspired
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
In the manuscript titled "Severity-Controlled Prediction Sets for Medication Recommendation", the authors described CSC, a post-hoc framework for calibrating medication prediction sets severity awared. This should be clinically better than other measures like recall, or Jaccard as not all errror are the same.
Strengths and weaknesses
Overall, the manuscript is well written, clear, and organized. The formal notation are well defined. Figure 1 illustrate well the context and the gap in which this work is. The authors introduce a novel framework for calibration method which is severity aware, CSC. This framework is may be applicable in other cases where different lables can be organized in a hierarchy.
Weknesses:
- Severity was not directly analyzed, but only distances in the hierarchy was considered as severity metric. This is a very simplifying assumption. The severity metric relies on a simplified hierarchy that may not reflect true clinical similarity. CSC severity is based on distance to LCA which assumes that hierarchical proximity corresponds directly to clinical interchangeability, which is not always true. Medications within the same ATC branch can have substantially different indications, contraindications, or safety profiles, while drugs from different branches may sometimes be clinically acceptable alternatives. Consequently, the claims of the paper about clinically meaningful severity reduction would be stronger if supported by clinician evaluation or alternative similarity measures beyond ATC taxonomy.
- The empirical evaluation is relatively narrow. All experiments are conducted on MIMIC-IV using a single LLM-based medication recommender, and comparisons are primarily against thresholding, Top-k, and CRC-FNR baselines. The paper does not demonstrate whether CSC consistently improves over stronger medication recommendation models or whether the method generalizes across different datasets or predictive architectures. Since CSC is presented as a model-agnostic framework, broader validation would strengthen the claims of the paper regarding its general applicability.
- The "ground truth" is not a gold-standard or expert-validated optimal medication regimen. It is simply what clinicians prescribed in the historical EHR. Therefore, CSC is calibrated to reproduce historical prescribing behavior, not necessarily the clinically best or safest treatment. This limitation should be mentioned as a limitation.
Questions
Q: Why is that only relevant for LLM? How about traditional predcition models?
In line 30, the authors used "CSC-calibrated sets". However, that was not defined yet and is not clear from the context.
The ATC system largely operates as a strict hierarchy, but a drug can fall into multiple therapeutic categories. How is such mulity hierarchy handled?
The maximal depth of the ATC hierarchy is 5 levels. Hoever, not all distances are equal. And here the authors used a "simple" measure wich is LCA in edges. Moreover, level 5 (Active Substance) is "closer" than level 4 (Chemical Subgroup) which is closer than level 3 (Pharmacological Subgroup) etc.
I suggest the authors publish their code as a stand-alone package, or at least as script for transperancy
I suggest the authors add a discussion section to discuss implications thier study and its limitations.
Limitations
No, the authors haven't discussed the limitations of their study. See weknesses above.
Final justification
Some of the questions were resolved. However, there are still some concerns regarding this work. Specifically, the title claims that the method is severity-controled. However distance in the ATC hierarchy does not implies severity. Moreover, the distance function is somwhat naive. Although the authors tested several distance functions. However they are all fixed for different subtrees. And the authors haven't addressed the multi-hierarchy nature of the ATC hierarchy. Where a drug or subtance can have multiple identifiers. So basically, different ids, in completely different subtrees will get a very high distance/severity score but they actually represent the exact same drug. For example S01AE07, J01MA14 for Moxifloxacin.
Formatting concerns
NA
5 comments
Rebuttal
Reviewer vVjX
We thank the reviewer for highlighting the manuscript's clarity and organization and the novelty and potential broader applicability of severity-aware calibration for hierarchical label spaces.
W1 — ATC-based severity as a simplifying surrogate
We clarify that CSC targets ATC taxonomy-based mismatch severity, measured by the LCA distance between each ground-truth drug and its closest predicted drug in the ATC hierarchy. Prior work has used ATC distance to quantify therapeutic drug similarity [1] and relatedness [2], providing established support for this measure. Indications, contraindications, and safety profiles require patient context and drug-specific clinical information beyond pairwise ATC distance; incorporating these factors may also violate the monotonicity required for CSC's finite-sample guarantee. We will explore clinician-grounded evaluation and alternative similarity measures that preserve this monotonicity requirement in future work.
W2 / Q1 — Applicability beyond LLM predictors
CSC is not LLM-specific, and we tested that CSC also meets the target using the non-LLM predictor DrugDoctor [3]. On matching MIMIC-IV patients, labels, the author-confirmed ordered 300-label vocabulary, and loss matrix, 100 paired bootstrap means at are loss/size for CSC-Avg and for CSC-Upper (). This demonstrates that CSC is predictor-agnostic and controls mismatch severity under a user-defined threshold.
| CSC-Avg loss / size | CSC-Upper loss / size | |
|---|---|---|
| 0.125 | 0.1203 / 43.52 | 0.1076 / 94.70 |
| 0.250 | 0.2471 / 24.65 | 0.2359 / 60.13 |
| 0.350 | 0.3476 / 16.71 | 0.3378 / 47.28 |
W3 — Historical prescriptions as ground truth
We agree that this is an important limitation of EHR-based medication recommendation. Following standard practice, we use observed prescriptions as labels, which reflect historical clinical decisions rather than an expert-validated gold standard. We will add this limitation and discuss its implications in the paper.
Q2 — Definition of “CSC-calibrated sets”
We agree that “CSC-calibrated sets” is confusing at that point, since CSC is only defined in Section 3.4. We will revise the wording so that the term is introduced where it is first used and state the configuration behind Figure 2 in its caption.
Q3 — Drugs associated with multiple therapeutic categories
Each ATC code has a unique path, so the LCA distance between any two labels is unique.
Q4 — Unequal distances across ATC hierarchy levels
We added a sensitivity analysis using three bounded monotone mappings of normalized LCA distance : , , and . For each definition, we recalibrated CSC-Avg independently at using the same patient splits, predictor scores, 401-point threshold grid, and 10-repeat bootstrap protocol.
| Severity mapping | Test risk | Set size | Recall | F1 | |
|---|---|---|---|---|---|
| 0.8538 | 0.2488 | 18.55 | 0.697 | 0.498 | |
| 0.8205 | 0.2471 | 16.25 | 0.657 | 0.508 | |
| 0.7695 | 0.2457 | 13.65 | 0.601 | 0.513 |
Each risk is defined on its own transformed severity scale and should be compared with within its row, not across rows.
Q5 — Code release
We will release the code as a standalone package upon publication.
Q6 — Discussion of implications and limitations
We appreciate the suggestion and will expand the Discussion section to cover CSC's implications and limitations, including ATC-based distance, nonlinear alternatives, reliance on historical prescriptions, and clinician validation.
References
[1] Wang et al., “Network predicting drug's anatomical therapeutic chemical code,” Bioinformatics, 2013.
[2] Bohn et al., “Large-scale Empirical Identification of Candidate Comparators for Pharmacoepidemiological Studies,” Drug Safety, 2025.
[3] Kuang and Xie, “DrugDoctor: Enhancing Drug Recommendation in Cold-Start Scenario via Visit-Level Representation Learning and Training,” Briefings in Bioinformatics, 2024.
Some of the concerns were resolved, but cruicial are still in place
W1 — ATC-based severity as a simplifying surrogate Indeed, ATC distance is associated with therapeutic drug similarity relatedness [2]. However it is not the same (or may even be an correlated with) severity. I did not mean that integration of contraindications and safter should be incorporated, but this type of information can explain why drugs relatdenes and distances within the ATC hierarchy cannot indicate drugs severities.
Q3 - ATC is a multi-hierarchy. And Drugs having more than one indication belong to more than one ATC code. See Mougin, Fleur, Anita Burgun, and Olivier Bodenreider. "Comparing drug-class membership in ATC and NDF-RT." Proceedings of the 2nd ACM SIGHIT International Health Informatics Symposium. 2012. And the example given of acetylsalicylic acid (aspirin). Another example, Moxifloxacin has 2 ATC codes (S01AE07, J01MA14) assigned.
Q4 - It seems that the authors just changed to reate of distance function decay (normalizing). But the assumption here is that different branches on the same level has the same aboslute distance. Which may not be true. It may be the case that for some subclasses, drugs are closer to eachother than in other parts of the hierarchy at the same level.
W1. Thank you for clarifying this distinction. CSC does not measure drug severity or clinical harm; it controls an ATC-taxonomy mismatch cost between a recommendation set and the observed medication labels. Prior work uses ATC to represent therapeutic and pharmacological relatedness [1,2], which motivates a structured mismatch surrogate but not a clinical-severity scale. We will revise the terminology throughout and clarify that CSC's finite-sample guarantee applies only to this prespecified surrogate.
Q3. Thank you for raising this point. The original NDC–RxCUI–ATC mapping of Kury and Bodenreider [4] preserves multiple ATC assignments, whereas our pipeline follows the GAMENet preprocessing implementation [5], which retains the first ATC assignment for each RxCUI. Consequently, every processed drug label is associated with a single ATC-4 code and a unique hierarchy path. We will explicitly describe this preprocessing choice and clarify that only the retained ATC-4 assignment is included in the evaluated label space. Conditional on this fixed processed label space, CSC’s conformal guarantee remains valid for the prespecified ATC-taxonomy mismatch cost.
[1] Wang et al., “Network predicting drug's anatomical therapeutic chemical code,” Bioinformatics, 2013.
[2] Bohn et al., “Large-scale Empirical Identification of Candidate Comparators for Pharmacoepidemiological Studies,” Drug Safety, 2025.
[3] Kuang and Xie, “DrugDoctor: Enhancing Drug Recommendation in Cold-Start Scenario via Visit-Level Representation Learning and Training,” Briefings in Bioinformatics, 2024.
[4] Kury, F. S. P., & Bodenreider, O. (2017). Mapping U.S. FDA National Drug Codes to Anatomical-Therapeutic-Chemical Classes Using RxNorm. AMIA Annual Symposium Proceedings.
[5] Shang, J., Xiao, C., Ma, T., Li, H., & Sun, J. (2019). GAMENet: Graph Augmented Memory Networks for Recommending Medication Combination. AAAI.
Q4. Thank you for the follow-up question. Equal cost within an LCA depth is a property of our original surrogate, not a requirement of CSC. The reviewer is correct that the earlier ablations changed only the global depth weighting and did not address variation across branches.
We therefore add a branch-dependent information-content cost. Let be the number of ATC-5 leaves below node , and let be the total number of ATC-5 leaves. For retained labels , we use the normalized Jiang--Conrath-style tree-path cost [6,7]:
where is the maximum numerator over the retained vocabulary and is fixed before calibration. Among the 302 retained-label pairs whose LCA has depth 3, the original cost is for every pair, whereas ranges from to with 252 distinct values.
| Cost | Test loss | Mean size | P/R/F1 | |
|---|---|---|---|---|
| Equal-edge LCA | .8225 | .2439 | 16.38 | .443/.661/.510 |
| Branch-dependent IC | .6950 | .2477 | 10.94 | .537/.529/.508 |
We independently recalibrated both costs at using the same scores and splits. Both satisfy their respective point targets; their loss values are not directly comparable because the scales differ. The IC cost selects a smaller set with higher precision and lower recall. Because the pairwise cost is fixed, bounded, and satisfies , the set loss remains monotone, so the CSC procedure is unchanged. This experiment addresses branch heterogeneity within ATC, not clinical-harm validity; equal-edge LCA remains our primary prespecified surrogate.
[6] Resnik, P. (1995). Using Information Content to Evaluate Semantic Similarity in a Taxonomy. IJCAI.
[7] Jiang, J. J., & Conrath, D. W. (1997). Semantic Similarity Based on Corpus Statistics and Lexical Taxonomy. Proceedings of ROCLING, 19--33.
- Rating
- 3/6
- Confidence
- 4/5
- Quality
- 2/4
- Clarity
- 3/4
- Significance
- 2/4
- Originality
- 2/4
- Contribution type
- use_inspired
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper proposes a post-hoc calibration method for multi-label medication recommendation. It replaces exact-match errors with an ATC-hierarchy-based mismatch severity and calibrates one global score threshold to control either average severity or the upper-quantile severity within each patient. This work provides a marginal expected-risk guarantee under exchangeability and evaluates the approach using an LLM-based drug recommender on MIMIC-IV.
Strengths and weaknesses
S1: The paper identifies a real limitation of exact-overlap metrics in medication recommendation. Using a structured notion of mismatch instead of treating every false negative identically is a useful perspective.
S2: CSC is simple to apply after model training and does not require changing the underlying recommender. The presentation is generally clear, and the distinction between average severity and within-patient upper-tail severity is intuitive.
W1: CSC seems to instantiate existing conformal risk control with a bounded and monotone hierarchy-based loss; the main theorem is therefore close to a direct CRC application rather than a substantially new conformal result. The paper should more clearly separate what is new in the loss design from what is inherited from CRC.
W2: With the stated correction term in Eq. (6), even the full prediction set gives a calibration quantity of at least , so the feasible set can be empty when , despite the theorem stating . The paper should state the needed condition, or define what happens when no threshold satisfies the calibration criterion.
W3: ATC proximity is not necessarily a valid proxy for clinical error severity or drug substitutability. Two nearby ATC codes can still differ substantially in indication, contraindications, dose, route, interaction risk, or patient-specific appropriateness; conversely, two drugs from different branches may both be clinically reasonable for the same patient. Without clinical validation or expert evidence, the proposed severity metric should be described as a taxonomy-based surrogate rather than clinical severity itself.
W4: CSC does not use the hierarchy to rerank or selectively replace medications at inference time. It only chooses a global score threshold, so lower severity is mechanically achieved by expanding the set until it contains more exact or nearby labels. This makes the claim that CSC favors therapeutically close predictions somewhat overstated, especially because distant high-score medications are not removed.
W5: The empirical evaluation is narrow for a method claimed to be model-agnostic and clinically relevant. Results are only shown on one single-center dataset, one LLM-based predictor, and the 300 most frequent ATC level-4 labels. External validation on a multi-center dataset such as eICU, a temporal or hospital-shift setting, and several distinct base recommenders would be important.
Questions
Based on the above weaknesses:
-
Can the authors clarify the precise technical novelty over standard CRC? Which part of the guarantee or proof would not follow directly from applying CRC to the proposed bounded monotone loss?
-
How should Eq. (6) and Theorem 3.2 be interpreted when ? Is always included in the search grid, and is there an explicit fallback when no candidate threshold is feasible?
-
Could the authors add comparisons that match CSC and all baselines by prediction-set size and recall, particularly for Figure 2? Reporting the corresponding precision, recall, and set-size distributions would help determine whether reduced severity comes from hierarchy-aware calibration rather than simply larger prediction sets.
-
What clinical evidence supports the use of ATC-tree distance as an error-severity metric? Could the authors include clinician assessment, medication substitution evidence, or an analysis that considers contraindications, drug-drug interactions, and indication-specific appropriateness? Moreover, can the authors test CSC on an external multi-center cohort and on non-LLM medication recommenders? If this is not feasible, the paper should narrow its claims about model-agnosticity and clinical generalizability.
Limitations
Authors didn't mention their limitations on both main part and appendix.
Final justification
-
W1 is clarified but only partially resolved: the contribution is better delimited, but the originality concern remains.
-
W2 is resolved: the proposed fallback and theorem correction address the technical issue.
-
W3 remains unresolved: ATC distance has not been validated as clinical severity, and the authors now explicitly characterize it only as a taxonomy-based surrogate.
-
W4 is confirmed: the matched comparisons show no fixed-budget hierarchy-composition advantage, materially weakening a central empirical claim.
-
W5 is partially resolved: a non-LLM predictor was added, but external and distribution-shift validation remain absent.
Therefore, I will maintain my original rating of 3 (Borderline Reject). I appreciate that the authors have responded carefully and have narrowed several claims.
Formatting concerns
NA
2 comments
Rebuttal
Reviewer kWLx
We thank the reviewer for recognizing the limitation of exact-overlap metrics, the value of structured mismatch severity, CSC's simple post-hoc applicability, and the intuitive distinction between average and within-patient upper-tail severity.
W1 / Q1 — Technical novelty over standard CRC
The technical novelty is proposing an ATC-based mismatch-severity objective for hierarchical multi-label prediction that satisfies the finite-sample guarantee from the CRC framework. The generic CRC guarantee is inherited; our contribution is constructing and validating the loss and delimiting what the resulting guarantee covers.
-
Monotonicity of the within-patient upper-quantile aggregation. Label-level severities being non-increasing in does not by itself give monotonicity of an average over the selected subset , because that subset changes with . The argument runs through the order statistics: elementwise domination of two collections implies domination of their descending order statistics, so the mean of the top severities is non-increasing. An arbitrary aggregator of label-level losses does not inherit monotonicity, and CRC fails without it.
-
Boundedness and monotonicity at the boundary. is a minimum over the predicted set and is undefined when ; assigning severity 1 there keeps the loss in and non-increasing across the transition from empty to non-empty sets.
-
Scope of the guarantee. indexes a within-patient quantile, so remains a per-example loss and stays CRC-compatible. Theorem 3.2 controls over patients and does not bound a quantile of severity across the population, which would require high-probability machinery such as RCPS.
Sections 3.2–3.5 and Eqs. (2)–(6) introduce the bounded closest-match surrogate, its empirical-CVaR aggregation over variable-size label sets, and the post-hoc -to-threshold rule; Proposition 3.1 proves set monotonicity even when tail membership changes. Theorem 3.2 then supplies marginal expected-risk control under exchangeability. We will separate these ingredients from the inherited CRC argument and revise Eq. (4) to state the exact empirical-CVaR definition with fractional boundary weight.
W2 / Q2 — Empty feasible set and fallback
We agree, and we will state the missing condition and fallback. Since , the calibration quantity in Eq. (6) is at least for every , so the feasible set is empty when , whereas Theorem 3.2 as written admits any . This is the resolution limit of CRC with .
We adopt the convention of Angelopoulos et al. (2024): when the feasible set is empty. Algorithm 1 already implements this by initializing and overwriting it only at a feasible candidate. We will state this convention in Eq. (6), Section 3.5, and Theorem 3.2. We will also add to the grid so that .
At , , so for every and for every . When no threshold is feasible, the guarantee therefore holds with the full vocabulary returned: valid, but uninformative. We will state Theorem 3.2 for , equivalently , as the informative regime. In our experiments , so , well below the smallest reported tolerance .
W3 — ATC proximity as a severity surrogate
We clarify that CSC controls ATC taxonomy-based mismatch severity, measured by the LCA distance between each ground-truth drug and its closest predicted drug. Indication, contraindication, dose, route, interaction risk, and patient-specific appropriateness require patient- and regimen-level information beyond drug-pair similarity. Moreover, adding contraindication or interaction penalties may increase the loss as the prediction set grows, violating the monotonicity required for CSC's finite-sample guarantee. Building on prior work that uses ATC distance to quantify therapeutic drug similarity and relatedness [1,2], CSC provides finite-sample control over this standardized mismatch measure. Following the reviewer's suggestion, we will use the term “ATC taxonomy-based mismatch severity” throughout the paper.
W4 — Inference-time behavior and set expansion
We agree with the reviewer's characterization. CSC leaves the base predictor's scores and ranking unchanged and, after calibration, applies a single global score cutoff. The ATC hierarchy enters only through the patient-level loss used to select that cutoff on held-out calibration data; it is not used to remove distant high-score medications, selectively insert ATC-near medications, or perform therapeutic substitution at inference time. Consequently, lower closest-match severity can arise mechanically as the nested prediction set expands.
The matched point-estimate diagnostics on the original, unresampled test split confirm that we do not obtain a fixed-budget composition advantage. At , CSC-Avg, recall-matched CRC-FNR, a size-matched score threshold, and size-matched Top- obtain average severities , , , and , respectively; the corresponding empirical-CVaR severities are , , , and . We have therefore removed the statement that CSC “favors therapeutically close predictions.” Our revised claim is that CSC directly calibrates a prespecified bounded ATC-based loss and provides marginal finite-sample expected-risk control under exchangeability, rather than reranking medications or producing therapeutically preferable sets at a fixed size.
W5 — Narrow evaluation
We evaluated CSC with DrugDoctor [3], a non-LLM recommender, and found that the same calibration interface satisfies all six prescribed risk targets. We replaced only the base score matrix with DrugDoctor scores, while keeping the MIMIC-IV patient split, ground-truth labels, ordered 300-label vocabulary, and loss matrix fixed; CSC-Upper uses empirical CVaR with .
| CSC-Avg loss / size | CSC-Upper loss / size | |
|---|---|---|
| 0.125 | 0.1197 / 43.86 | 0.1103 / 93.81 |
| 0.250 | 0.2464 / 24.73 | 0.2436 / 58.86 |
| 0.350 | 0.3462 / 16.73 | 0.3337 / 47.63 |
Across 100 paired bootstrap repetitions at , mean loss/size is for CSC-Avg and for CSC-Upper. This demonstrates empirical portability across one LLM and one non-LLM scorer on MIMIC-IV; CSC calibrates rather than replaces or improves the base recommender. A hospital shift may break exchangeability if the calibration set has no access to the new distribution and is therefore outside the present scope.
Q3 — Size- and recall-matched comparisons
We selected size- and recall-matching targets using calibration data, locked all methods, and evaluated them once on the original test split:
| Method | Mean size; median [IQR] | Avg. loss | Precision / Recall / F1 |
|---|---|---|---|
| CSC-Avg () | 28.53; 27 [17, 37] | 0.1218 | 0.315 / 0.813 / 0.438 |
| Size-matched Top- () | 28; 28 [28, 28] | 0.1108 | 0.303 / 0.821 / 0.405 |
| Recall-matched Top- () | 27; 27 [27, 27] | 0.1171 | 0.310 / 0.813 / 0.410 |
This supports target-risk calibration rather than hierarchy-aware reranking or uniform fixed-budget superiority. We will add the full size distribution and precision/recall/F1 to the Figure 2 discussion and label the rows as efficiency diagnostics.
Q4 — Clinical evidence, external validation, and non-LLM recommenders
As detailed under W3, CSC controls ATC taxonomy-based mismatch severity rather than patient-specific clinical harm or drug substitutability. The WHO ATC taxonomy provides a standardized, expert-curated basis for this surrogate, and prior work has used ATC distance and proximity to quantify therapeutic similarity and relatedness [1,2]. Contraindications, interactions, dose, route, and indication-specific appropriateness require patient-level clinical validation and are beyond our scope.
As detailed under W5, CSC also satisfies all six prescribed risk targets with the non-LLM recommender DrugDoctor while keeping the data split, label space, and severity matrix fixed. This demonstrates that CSC is not tied to LLM-generated scores and can calibrate different predictors under mismatch-severity control.
References
[1] Wang et al., “Network predicting drug's anatomical therapeutic chemical code,” Bioinformatics, 2013.
[2] Bohn et al., “Large-scale Empirical Identification of Candidate Comparators for Pharmacoepidemiological Studies,” Drug Safety, 2025.
[3] Kuang and Xie, “DrugDoctor: Enhancing Drug Recommendation in Cold-Start Scenario via Visit-Level Representation Learning and Training,” Briefings in Bioinformatics, 2024.
I appreciate that the authors have responded carefully and have narrowed several claims. Nevertheless, the two most consequential concerns remain: the controlled quantity lacks clinical validation, and the new evidence confirms that the observed reduction in ATC mismatch is primarily associated with set expansion rather than hierarchy-aware improvement of prediction-set composition. Combined with the largely inherited CRC guarantee, this substantially limits the paper's demonstrated novelty and practical significance. Therefore, I will maintain my original rating of 3.
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- use_inspired
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper introduces Conformal Severity Control (CSC), a post-hoc method for calibrating medication prediction sets under a hierarchy-aware severity: instead of scoring a missed drug as a binary error, it uses ATC-tree distance to penalize distant mismatches more than therapeutically close ones, defines average and upper-quantile patient-level severity losses, and picks a single threshold via conformal risk control (CRC) so expected severity stays under a user-set tolerance. Experiments are on MIMIC-IV with a fine-tuned Meerkat-8B recommender.
Strengths and weaknesses
Strengths
- Strong, well-motivated problem. Treating a close ATC match the same as a distant one is a real weakness of recall/F1/FNR evaluation, and Figures 1–2 make the case clearly.
- Correct, clean theory. The severity loss satisfies the boundedness and monotonicity conditions CRC needs (Prop. 3.1), and Thm. 3.2 is a correct instantiation; the β=0 reduction to average severity is handled properly.
- Practical framing. Post-hoc, model-agnostic, no retraining; Algorithm 1 is concrete and the discrete-grid implementation is efficient.
- Patient-adaptivity. Figure 5 shows a single global threshold induces patient-specific set sizes that track ground-truth medication count, which fixed Top-k cannot do.
Weaknesses
- Incremental novelty. The engine is off-the-shelf CRC; what is new is the loss choice and the upper-quantile aggregation. Reasonable for an application paper, but it puts the burden on the empirical results.
- Weak separation from baselines. In Tables 2 and 8, CRC-FNR and a tuned score threshold matched on recall/size reach essentially the same severity (Table 8: 0.245 vs 0.245 vs 0.239) and comparable severity-radius coverage, sometimes slightly better. So a practitioner can hit the same severity with a tuned cutoff, leaving the finite-sample guarantee and the "severity knob" as the main advantage rather than better prediction sets.
- Severity control is close to a size/recall reparametrization. Severity is 0 whenever the true drug is in the set and non-increasing in the threshold, so the target can always be met by enlarging the set. The distinguishing case (lower ATC severity at a fixed set size) is never isolated, and the size-matched Score-top-k row suggests the gap is small.
- Unvalidated severity proxy. ATC distance stands in for clinical severity, but same-subgroup drugs can differ sharply in safety while distant drugs can be interchangeable. There is no sensitivity analysis over alternative severity definitions and no clinician-grounded check.
- Narrow evaluation. One dataset and one predictor is thin for a method whose selling point is being model-agnostic. App. C.3 twice refers to "across datasets," which reads like leftover text since only MIMIC-IV is used.
Questions
- Can you show a regime where CSC beats the matched baselines it currently ties? A small calibration split (severity vs. n_cal), miscalibrated base scores, or a mild distribution shift where a tuned score threshold overshoots the target severity out-of-sample while CSC holds. This is the result most likely to change my score.
- At a fixed prediction-set size, do CSC sets have lower ATC severity than size-matched recall-optimized sets? This isolates the hierarchical-weighting benefit from the set-size effect, which is the paper's core claim.
- How sensitive are results to the severity definition? An ablation over 2–3 alternatives to (nonlinear weighting, or interaction/safety-informed weights) would show the conclusions are not an artifact of that form.
- Can you add a second predictor (a non-LLM recommender) and/or a second dataset, and reconcile the "across datasets" wording in App. C.3 with the single-dataset setup?
- Since each β is calibrated separately, can you disentangle the objective from re-calibration in Fig. 4b (e.g., evaluate upper-quantile severity under a fixed λ across β)?
I would raise my rating if the first two questions show a concrete advantage over matched baselines and evaluation is broadened; I would lower it if the severity metric proves highly sensitive without justification.
Limitations
Partially addressed.
- Good: the authors are clear that the guarantee bounds expected severity marginally, not per-patient or population-quantile severity.
- Under-discussed: clinical validity of ATC distance as a severity proxy; the near-equivalence to matched baselines as a limit on practical utility; reliance on one dataset and one model; behavior under miscalibration or temporal distribution shift (exchangeability is not obvious in inpatient EHR data).
- A short note on the deployment risk of optimizing an ontology-distance surrogate, and a brief societal-impact statement given the clinical setting, would help.
Final justification
Thanks for the additional experiments, I raised my score then.
Formatting concerns
None
2 comments
Rebuttal
Reviewer gJP6
We thank the reviewer for recognizing the importance of severity-aware medication evaluation, the correctness and clarity of our CRC instantiation, CSC's practical post-hoc design, and the patient-adaptive set sizes induced by a single global threshold.
W1 — Incremental novelty
CSC formulates mismatch-severity-controlled prediction sets for hierarchical multi-label medication recommendation using (i) a bounded closest-match loss for variable-size label sets, (ii) patient-level upper-tail aggregation, and (iii) a monotone post-hoc threshold that converts a hierarchy-based severity budget into adaptive sets with finite-sample risk control. Without these ATC-based loss formulations, CSC reduces to standard overlap-risk calibration.
Sections 3.2–3.5 and Eqs. (2)–(6) define the bounded closest-match surrogate, empirical-CVaR aggregation for variable-size label sets, and post-hoc threshold rule; Proposition 3.1 verifies boundedness and monotonicity, and Algorithm 1 implements the calibration. The generic CRC argument in Theorem 3.2 is inherited rather than claimed as a new general theorem. We will separate these contributions and revise Eq. (4) to the exact empirical-CVaR form with fractional boundary weight throughout.
W2 — Weak separation from baselines
We add a direct comparison with a plug-in rule that uses the same predictor, ATC loss, and threshold family, but omits the finite-sample CRC correction. At and , CSC reduces the fixed-test empirical target-exceedance fraction from to and the mean held-out loss from to , at the cost of increasing the mean set size from to . Thus, CSC's distinguishing contribution is reliable finite-sample calibration of the requested ATC-risk level, rather than a different ranking or uniformly better point performance at a matched budget.
W3 — Severity control and set-size reparametrization
CSC's role is to select the least inclusive operating point in the nested prediction-set family that satisfies the finite-sample-corrected risk target. Further enlargement may reduce the surrogate loss, but is unnecessary once the target is met and typically lowers precision. Eq. (1) fixes the predictor ranking, while Eq. (6) and Algorithm 1 select the threshold; the full vocabulary is only the trivial zero-loss endpoint. The small-calibration diagnostic isolates the correction: at , empirical exceedance falls from to , with mean size increasing from to . We will remove fixed-cardinality composition language and report set size and precision explicitly as efficiency costs.
W4 — Unvalidated severity proxy
The WHO ATC system organizes drugs by their anatomical, therapeutic, pharmacological, and chemical properties, so drugs sharing a deeper ATC ancestor are more closely related within this standardized therapeutic taxonomy. Prior work has used distances between ATC codes to quantify therapeutic drug similarity [1] and ATC proximity to characterize pharmacologic and therapeutic relatedness [2]. Accordingly, we use ATC-based LCA distance as a principled measure of medication mismatch severity between the predicted and ground-truth drugs.
W5 / Q4 — Narrow evaluation and a second predictor
Without changing the CSC framework, the DrugDoctor-based non-LLM experiment meets all six full-calibration point targets. We changed only the DrugDoctor scores; patient IDs, labels, the ordered 300-label vocabulary, and the loss matrix remain fixed. CSC-Upper uses empirical CVaR with .
| CSC-Avg loss / size | CSC-Upper loss / size | |
|---|---|---|
| 0.125 | 0.1197 / 43.86 | 0.1103 / 93.81 |
| 0.250 | 0.2464 / 24.73 | 0.2436 / 58.86 |
| 0.350 | 0.3462 / 16.73 | 0.3337 / 47.63 |
Under the same 10-repeat bootstrap protocol, CSC-Avg obtained mean test severities at , with mean set sizes . CSC-Upper obtained , with mean set sizes . Thus, all six mean empirical test losses were below their corresponding targets. In 100 paired bootstrap repetitions at , mean loss/size was for CSC-Avg and for CSC-Upper.
This provides evidence for one LLM and one non-LLM scorer on MIMIC-IV; external and multi-center validation remain open. Because the supplied files do not establish training/model-selection isolation, we treat this as an empirical post-hoc application rather than invoking Theorem 3.2. We will replace “across datasets” with “within MIMIC-IV” in Appendix C.3 and state this scope in the abstract and limitations.
Q1 — A regime where CSC separates from the matched baseline
Yes—in the small-calibration regime, CSC more reliably meets the target risk than an otherwise identical plug-in threshold, at the cost of selecting larger prediction sets. At , we drew 100 without-replacement calibration subsamples for each and evaluated all locked rules on the same fixed test split; brackets are empirical 2.5–97.5% calibration-resampling quantiles.
| CSC: loss [q] / size / exceedance | Plug-in: loss [q] / size / exceedance | |
|---|---|---|
| 25 | 0.214 [0.154, 0.287] / 18.67 / 13% | 0.245 [0.171, 0.319] / 16.60 / 40% |
| 50 | 0.230 [0.183, 0.284] / 17.44 / 19% | 0.245 [0.198, 0.303] / 16.45 / 41% |
| 100 | 0.238 [0.203, 0.275] / 16.80 / 28% | 0.246 [0.210, 0.287] / 16.35 / 38% |
The plug-in rule tunes the identical loss and threshold family but omits Eq. (6)'s correction. At , CSC reduces empirical exceedance from to and mean loss from to , at the cost of 2.07 additional labels. “Exceedance” is a fixed-test empirical fraction across calibration subsamples, not a theorem failure probability. We will add this diagnostic and distinguish calibration reliability from ranking performance.
Q2 — Fixed-size comparison
At matched average set size, the comparison shows that CSC's contribution is direct calibration to a prespecified ATC-risk tolerance, rather than uniformly minimizing the point loss at every fixed budget. At , CSC-Avg has loss/mean-size , compared with for size-matched Top-; CSC-Upper has empirical-CVaR loss/mean-size , compared with for Top-. For patient-specific CSC cardinality , Eq. (1) yields the predictor's Top- set up to score ties because CSC does not alter the ranking. CSC instead uses Eq. (6) to select a global cutoff for a user-specified ATC-risk tolerance with finite-sample expected-risk control. This cutoff induces patient-specific set sizes, whereas fixed Top- imposes the same cardinality on every patient and provides no corresponding guarantee for the prespecified ATC-based loss. We will present the matched-size comparison as a diagnostic and clarify that CSC is a risk-calibration method rather than a fixed-budget reranking method.
Q3 — Sensitivity to the severity definition
We added a sensitivity analysis using three bounded monotone mappings of normalized LCA distance : , , and . Each definition was recalibrated independently at using the same splits, scores, threshold grid, and bootstrap protocol. The mean empirical risks remain near their target within each definition, while the expected set-size trade-off changes with the severity scale.
| Severity mapping | Test risk | Set size | Recall | F1 | |
|---|---|---|---|---|---|
| 0.8538 | 0.2488 | 18.55 | 0.697 | 0.498 | |
| 0.8205 | 0.2471 | 16.25 | 0.657 | 0.508 | |
| 0.7695 | 0.2457 | 13.65 | 0.601 | 0.513 |
Each risk is defined on its own transformed severity scale and should be compared with within its row, not across rows. Interaction- and safety-informed weights cannot be included if they violate the monotonicity constraint required for the CSC loss.
Q5 — Separating the upper-tail objective from recalibration
We agree that the original analysis conflated the definition of the upper-tail objective with threshold recalibration. At , separate calibration for selected mean thresholds , producing mean set sizes and empirical-CVaR losses .
We then fixed, within each bootstrap repetition, the threshold selected at and evaluated all three values on exactly the same test prediction sets.
| Separately calibrated | Separate size | Separate CVaR | Fixed- size | Fixed- CVaR | |
|---|---|---|---|---|---|
| 0.50 | 0.9273 | 27.45 | 0.2470 | 40.41 | 0.1360 |
| 0.75 | 0.9668 | 40.41 | 0.2385 | 40.41 | 0.2385 |
| 0.90 | 0.9825 | 54.05 | 0.2382 | 40.41 | 0.3583 |
Increasing raises the emphasis on the highest-severity labels even when the set is unchanged. The larger separately calibrated sets reflect recalibration toward ; the fixed- loss at is not expected to remain below . For the fixed analysis, and the test resample are held fixed within each of the 10 bootstrap repetitions.
References
[1] Wang et al., “Network predicting drug’s anatomical therapeutic chemical code,” Bioinformatics, 2013.
[2] Bohn et al., “Large-scale Empirical Identification of Candidate Comparators for Pharmacoepidemiological Studies,” Drug Safety, 2025.
[3] Kuang and Xie, “DrugDoctor: Enhancing Drug Recommendation in Cold-Start Scenario via Visit-Level Representation Learning and Training,” Briefings in Bioinformatics, 2024.
Thanks the authors for detailed responses and additional experiments, I will raise my score then.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
We thank the AC for summarizing the discussion. The rebuttal and follow-up experiments have directly addressed the critical concern and clarified the scope of CSC’s contribution.
Critical concern: interpretation of the ATC-based quantity. CSC does not claim to measure drug severity, patient harm, therapeutic equivalence, or treatment safety. It controls a prespecified ATC-taxonomy mismatch cost between a prediction set and the observed medication labels. ATC remains central to the method because it replaces a flat exact-match loss, which treats all missed medications identically, with a standardized graded structure over the label space. The finite-sample guarantee applies precisely to this taxonomy-defined risk under exchangeability. In the revision, we will consistently write “ATC-taxonomy mismatch cost/risk” and align the abstract, figures, and conclusions with the precise scope of the formal guarantee.
We also addressed the structural concerns about this surrogate. We documented the single-ATC-4 preprocessing rule used in the evaluated label space and added a branch-dependent information-content cost. Among 302 label pairs with the same LCA depth, the original cost is always .25, whereas the branch-dependent cost ranges from .081 to .449 with 252 distinct values. After independent recalibration, CSC again satisfies the prescribed target. Thus, CSC is not restricted to equal edge costs across ATC branches, while neither taxonomy cost is interpreted as clinical harm.
Major concerns. We clarified that CSC provides finite-sample risk calibration rather than hierarchy-based reranking. In the requested small-calibration comparison, CSC and the plug-in rule use the same predictor, loss, and candidate sets; at ncal=25, the CRC correction reduced the fixed-test empirical target-exceedance fraction from 40% to 13% and mean loss from .245 to .214, with the transparent cost of increasing mean set size from 16.60 to 18.67. We also added a non-LLM DrugDoctor experiment, the requested fixed-λ analysis across β, complete size/recall-matched diagnostics, and the explicit full-set fallback in Eq. (6) and Algorithm 1.
These results leave a precise methodological contribution: CSC converts a user-specified hierarchical multi-label risk, including a within-patient upper-tail objective, into a single post-hoc threshold with finite-sample expected-risk control under exchangeability, without retraining or requiring probabilistically calibrated scores. The remaining limitations define the scope of this result rather than undermine it.