Preserving Geometric Symmetry in Uncertainty Estimation for Molecular Forces
Xinyu Li, Zhen Zhang, Jiayu Huang, Daniel M. Steinberg, Lina Yao, Javen Qinfeng Shi
NeurIPS 2026
TL;DR. This paper introduces a novel uncertainty estimation method that accurately predicts vector-valued properties, such as molecular forces, by explicitly accounting for underlying 3D rotational symmetries.
Abstract. Accurate and reliable uncertainty estimation (UE) for vector-valued physical properties is crucial for scientific discovery in fields like drug and materials discovery. For example, atomic forces are central to finding optimal structures and identifying equilibrium systems, and a fundamental requirement of these vectors is that they must be equivariant under 3D rotations. However, existing UE methods often fail to respect these geometric constraints, leading to poorly calibrated uncertainty and degraded predictive performance. To address the problem, we introduce a novel framework for equivariant multivariate evidential regression. Our primary contribution is a theoretically grounded parameterization of the evidential prior's scale matrix, constructed via a decomposition into an invariant scalar component and an equivariant low-rank term. Furthermore, we address the lack of suitable evaluation standards for vector fields by introducing a rigorous calibration metric based on the Mahalanobis distance. Extensive experiments on molecular property prediction benchmarks, including MD17, QM7-X, and OC20, show that our framework consistently outperforms established baselines, achieving state-of-the-art single-model predictive accuracy with well-calibrated uncertainty. This work provides a principled and practical approach to uncertainty estimation for equivariant vector-valued properties, paving the way for more trustworthy machine learning applications in scientific discovery.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:47 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
I reviewed the authors' response and the discussion. Two reviewers moved from 4 to 5. The third stayed at 3 because of concerns about physical consistency, scope, and significance.
The paper proposes an SO(3)-equivariant covariance model for uncertainty on vector-valued molecular properties, along with a coordinate-independent calibration metric. The response added the main missing control: a matched Gaussian-NLL model. EMER-D has lower force error on all seven MD17 systems, but its calibration advantage is limited to four, mainly rigid or anisotropic, systems. The authors also added seed variation, recent baselines, standard calibration metrics, random acquisition, measured compute costs, and conservative-force OC20 results.
The response answers the main attribution questions. The remaining disagreement is about scope and practical importance rather than a missing control. Dropout remains important, MER-D is best calibrated in the conservative-force experiment, dipole covariance has not been tested under size shift, and the uncertainty head is not derived from a joint energy-force model. The added controls and broad evaluation are sufficient, so I recommend acceptance.
Final justification
My final justification is included in the metareview above.
- Final justification
- My final justification is included in the metareview above.
Read meta-review
Meta-review
I reviewed the authors' response and the discussion. Two reviewers moved from 4 to 5. The third stayed at 3 because of concerns about physical consistency, scope, and significance.
The paper proposes an SO(3)-equivariant covariance model for uncertainty on vector-valued molecular properties, along with a coordinate-independent calibration metric. The response added the main missing control: a matched Gaussian-NLL model. EMER-D has lower force error on all seven MD17 systems, but its calibration advantage is limited to four, mainly rigid or anisotropic, systems. The authors also added seed variation, recent baselines, standard calibration metrics, random acquisition, measured compute costs, and conservative-force OC20 results.
The response answers the main attribution questions. The remaining disagreement is about scope and practical importance rather than a missing control. Dropout remains important, MER-D is best calibrated in the conservative-force experiment, dipole covariance has not been tested under size shift, and the uncertainty head is not derived from a joint energy-force model. The added controls and broad evaluation are sufficient, so I recommend acceptance.
1 comment
- Rating
- 5/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 4/4
- Significance
- 4/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This work addresses the problem of uncertainty estimation for equivariant vector-valued functions, especially relevant in molecular properties. The paper introduces Equivariant Multivariate Evidential Regression (EMER), an evidential deep learning framework based on a novel parameterization of the Normal-Inverse-Wishart scale matrix. In addition, a Mahalanobis distance-based calibration metric suited for vector-valued outputs is introduced. The paper's claims are well described, the theoretical contributions are clearly presented, and the results encompass a broad class of models and datasets.
Strengths and weaknesses
Strengths
-
Principled and model-agnostic framework. The proposed evidential parameterization is clean, theoretically grounded, and backbone-agnostic: it can be attached to any equivariant model (EGNN, PaiNN, NequIP, MACE in the paper) without architectural modifications.
-
Novel and appropriate calibration metric. The Mahalanobis calibration score (MCal) is a nice contribution.
-
Extensive experiments. The paper performs extensive experiments, varying datasets, tasks, and models. Overall, this strengthens the paper.
Weaknesses
-
EMER alone does not produce well-calibrated uncertainty. Inspecting the results, EMER (without dropout) exhibits MCal and NLL values that are substantially worse than most baselines, including MC Dropout and vanilla MER. This implies that the NIW evidential prior, as implemented, leads to overconfident or poorly conditioned covariance estimates. The real source of calibration improvement is dropout regularization (EMER-D), which is applied only at training time as a regularizer. This raises a fundamental question: what is the evidential prior actually contributing beyond what a simpler regularized predictor would provide? This concern is reinforced by prior work (Tan et al., 2023 [arXiv:2305.01754]), who systematically evaluated evidential regression for neural network potentials and found it was not the preferred alternative over ensembles in any of the settings tested.
-
Missing recent and relevant baselines. Several important baselines are absent; a search led me to: (i) BLIP (Bayesian Learned Interatomic Potentials [arXiv:2508.14022]), a scalable architecture-agnostic variational Bayesian framework built on adaptive Variational Dropout, which integrates with equivariant message-passing architectures and has been shown to outperform ensembles while providing calibrated uncertainty with minimal overhead. (ii) The methods evaluated in Tan et al., 2023 [arXiv:2305.01754], which are also relevant to the claim of state-of-the-art accuracy and calibration. The paper represents a de facto standard approach to UQ in MLIP, and the same tests should be performed to claim SOTA,
-
Ensemble performance is not clearly surpassed. Inspecting the results, it is clear that Ensembles achieve competitive performance on several molecules. The claim of state-of-the-art accuracy should be qualified, especially given that no standard deviations across seeds are reported. The paper acknowledges results are averaged over three seeds, but without confidence intervals, it is impossible to assess whether differences between methods are statistically significant.
-
Calibration metrics are not validated against established standards. The paper introduces MCal as a new metric and primarily evaluates methods through it, but does not verify whether MCal rankings agree with the correlation-based metrics proposed by Tan et al., which relate predicted uncertainty directly to empirical model error.
Questions
-
Adding the backbone name to each table caption would make the tables self-contained and easier to reference. Can you do it?
-
The paper references PaiNN but misses the citation in the main text at line 312. This should be corrected.
-
Why does MACE underperform PaiNN and NequIP in Table 2? MACE is generally considered the strongest backbone among those tested, so this is surprising. Is MACE used here as pretrained and fine-tuned, or trained from scratch?
-
Can you add to Figure 2: (1) a random acquisition baseline (querying random samples instead of using uncertainty), which is the standard sanity check in active learning, and (2) a fully supervised upper bound trained on all available data (or a random sample of 200 data points matching the total budget). Without these, it is difficult to assess whether the observed MAE differences across UE methods are meaningful or whether any informed acquisition strategy meaningfully outperforms random selection.
Limitations
Yes.
Final justification
I recommend accepting the paper. The proposed method is novel, and its evidential parameterization is clean, theoretically grounded, and backbone-agnostic. Furthermore, the authors introduce a new calibration metric that could be highly useful to practitioners.
During the rebuttal, the authors addressed most of my comments by providing additional experiments and revising unclear phrasing in the paper. Although dropout remains necessary for the model to train properly, this is a standard technique for preventing overfitting in deep learning models, including transformers. In my view, this issue is not sufficient grounds for rejecting the paper.
Overall, I am inclined to support acceptance, as principled, model-agnostic uncertainty quantification is currently lacking for machine-learning force fields. This work could help advance the state of the field. Following the rebuttal, I increased my score from 4 to 5.
Formatting concerns
No issues found.
5 comments
We thank the reviewer for the positive assessment and detailed suggestions. We address the main weaknesses first.
W1: EMER alone, dropout, and what the evidential prior contributes
R1: We agree that raw EMER is not the model we should emphasize regards calibration. Dropout is a training-time regularizer, not MC-dropout at inference, and it mainly improves overall calibration. The clean test for equivariance is therefore MER-D versus EMER-D at fixed dropout: EMER-D improves Max RCal on 20 of 21 seed-matched MD17-RotOOD runs. For example, it reduces Max RCal from 0.706 to 0.156 on naphthalene, 0.617 to 0.120 on salicylic acid, 0.811 to 0.283 on uracil, and 0.450 to 0.182 on toluene. This identifies the contribution of equivariant covariance to dimension-wise calibration and NLL.
We also include a direct equivariant Gaussian-NLL control as requested by Reviewer qrbk to isolate the NIW prior's contribution.
Table R1. MD17-RotOOD; mean(std), seeds 1/10/100. bold = best. GMM is Tan et al.; BLIP uses β=0.1.
| Mol | Metric | EMER | Gauss | MER-D | EMER-D | Gauss-D | GMM | BLIP |
|---|---|---|---|---|---|---|---|---|
| Aspirin | Force MAE | 0.403(0.008) | 0.431(0.010) | 0.421(0.003) | 0.394(0.007) | 0.423(0.004) | 0.509(0.006) | 0.477(0.004) |
| MCal | 1.361(0.024) | 1.200(0.013) | 0.221(0.015) | 0.173(0.024) | 0.142(0.038) | 0.405(0.073) | 1.319(0.008) | |
| Max RCal | 0.947(0.025) | 0.755(0.007) | 0.345(0.015) | 0.154(0.019) | 0.072(0.021) | 0.378(0.043) | 0.875(0.009) | |
| Ethanol | Force MAE | 0.277(0.012) | 0.273(0.008) | 0.280(0.014) | 0.277(0.007) | 0.279(0.013) | 0.317(0.000) | 0.304(0.007) |
| MCal | 1.476(0.010) | 1.394(0.011) | 0.244(0.092) | 0.265(0.029) | 0.149(0.003) | 0.590(0.117) | 0.748(0.018) | |
| Max RCal | 1.061(0.007) | 0.926(0.022) | 0.295(0.060) | 0.217(0.023) | 0.083(0.008) | 0.417(0.084) | 0.448(0.009) | |
| Nap | Force MAE | 0.101(0.003) | 0.118(0.004) | 0.156(0.014) | 0.162(0.006) | 0.171(0.012) | 0.130(0.001) | 0.124(0.002) |
| MCal | 0.784(0.049) | 0.563(0.089) | 0.201(0.065) | 0.147(0.028) | 0.428(0.091) | 0.310(0.045) | 0.334(0.051) | |
| Max RCal | 0.559(0.030) | 0.384(0.055) | 0.706(0.050) | 0.156(0.041) | 0.355(0.069) | 0.543(0.021) | 0.272(0.022) | |
| MDA | Force MAE | 0.413(0.022) | 0.420(0.015) | 0.398(0.021) | 0.397(0.010) | 0.403(0.017) | 0.486(0.031) | 0.461(0.010) |
| MCal | 1.494(0.011) | 1.382(0.048) | 0.366(0.063) | 0.407(0.044) | 0.191(0.059) | 0.511(0.035) | 1.211(0.014) | |
| Max RCal | 1.098(0.010) | 0.925(0.060) | 0.420(0.038) | 0.310(0.036) | 0.126(0.050) | 0.401(0.030) | 0.770(0.004) | |
| SAC | Force MAE | 0.259(0.005) | 0.280(0.004) | 0.289(0.007) | 0.269(0.005) | 0.305(0.013) | 0.333(0.008) | 0.312(0.010) |
| MCal | 1.235(0.015) | 1.034(0.028) | 0.186(0.044) | 0.221(0.063) | 0.385(0.123) | 0.450(0.035) | 0.932(0.029) | |
| Max RCal | 0.844(0.023) | 0.637(0.029) | 0.617(0.031) | 0.120(0.040) | 0.259(0.082) | 0.635(0.025) | 0.646(0.029) | |
| Uracil | Force MAE | 0.169(0.003) | 0.195(0.012) | 0.206(0.003) | 0.193(0.004) | 0.233(0.004) | 0.215(0.005) | 0.219(0.010) |
| MCal | 1.130(0.019) | 0.939(0.023) | 0.225(0.013) | 0.519(0.054) | 0.636(0.084) | 0.518(0.041) | 0.484(0.035) | |
| Max RCal | 0.764(0.014) | 0.562(0.008) | 0.811(0.014) | 0.283(0.046) | 0.385(0.069) | 0.681(0.027) | 0.383(0.021) | |
| Toluene | Force MAE | 0.123(0.001) | 0.139(0.006) | 0.155(0.015) | 0.158(0.006) | 0.170(0.018) | 0.152(0.005) | 0.147(0.002) |
| MCal | 1.027(0.019) | 0.900(0.064) | 0.207(0.177) | 0.247(0.103) | 0.440(0.126) | 0.502(0.005) | 0.187(0.037) | |
| Max RCal | 0.706(0.015) | 0.557(0.049) | 0.450(0.056) | 0.182(0.045) | 0.309(0.070) | 0.498(0.009) | 0.144(0.014) |
The Gaussian comparison is not a universal win: EMER-D improves force MAE in 17/21 matched-seed comparisons, while Gaussian-D is better calibrated on some small/flexible molecules. The resulting role split is: the NIW prior primarily improves force accuracy; dropout improves overall calibration; and equivariant covariance improves dimension-wise calibration and NLL, especially on anisotropic/ring systems. We therefore do not claim that the NIW prior alone solves calibration.
W2: Missing BLIP and Tan et al. baselines
R2: We added both as shown in Table R1. At its fair setting (β=0.1), BLIP does not lead on any reported force-MAE row and wins only two individual calibration cells (toluene MCal and Max RCal); GMM does not win a reported cell. Thus, neither baseline gives a consistent advantage over the proposed method. The default BLIP setting β=10 over-regularizes under our normalized loss, so β=0.1 is the fair setting reported above.
Tan et al. (2023) fit a GMM to learned features and use density/NLL as uncertainty; therefore it is nonequivariant UE method, worse Max RCal/NLL under rotation is expected. We will add both baselines to Additional Results at PDF p.19, line 714.
W3: Ensembles and standard deviations
R3: Following Wollschläger et al. (ICML 2023, arXiv:2306.14916), we treat ensembles as the gold-standard UQ reference, not a row-wise accuracy target. This is consistent with Tan et al. (2023), who find that single-model UQ does not consistently outperform ensembles. When manuscript revision is permitted, we will replace state-of-the-art predictive accuracy at PDF p.1, lines 15--16 with state-of-the-art single-model predictive accuracy.
Regarding standard deviations, Table R3 gives paired comparisons for the two molecules with the largest ensemble F-MAE advantage; Δ/σ denotes the difference in EMER-D standard-deviation units.
| Mol | Metric | Ens. | EMER-D | Δ/σ |
|---|---|---|---|---|
| Aspirin | F-MAE | 0.3744(0.0074) | 0.3936(0.0072) | 2.7x |
| MCal | 0.8407(0.0071) | 0.1730(0.0236) | 28.3x | |
| Max RCal | 0.1504(0.0017) | 0.1536(0.0190) | 0.2x | |
| Ethanol | F-MAE | 0.2454(0.0021) | 0.2770(0.0067) | 4.7x |
| MCal | 0.6687(0.0447) | 0.2652(0.0290) | 13.9x | |
| Max RCal | 0.0830(0.0121) | 0.2169(0.0227) | 5.9x |
These paired results preserve the mean-result conclusion: ensembles lead F-MAE/Max RCal, whereas the MER family leads MCal.
W4: MCal and correlation-based metrics
R4: Tan et al. (arXiv:2305.01754) uses metrices of Spearman rank correlation, ROC-AUC, and miscalibration area; we computed all three for MER-D, EMER-D and Gauss-D on MD17-RotOOD.
MCal generally agrees with the established scalar diagnostics. Table R2 reports all five metrics for every method and molecule, mean(std) over same seeds 1/10/100.
| Mol | Metric | MER-D | EMER-D | Gauss-D |
|---|---|---|---|---|
| Aspirin | MCal | 0.221(0.015) | 0.173(0.024) | 0.142(0.038) |
| Max RCal | 0.345(0.015) | 0.154(0.019) | 0.072(0.021) | |
| MiscalArea | 0.062(0.005) | 0.050(0.007) | 0.040(0.010) | |
| Spearman | 0.756(0.004) | 0.744(0.007) | 0.756(0.005) | |
| ROC-AUC | 0.877(0.001) | 0.873(0.004) | 0.876(0.001) | |
| Ethanol | MCal | 0.244(0.092) | 0.265(0.029) | 0.149(0.003) |
| Max RCal | 0.295(0.060) | 0.217(0.023) | 0.083(0.008) | |
| MiscalArea | 0.068(0.029) | 0.077(0.009) | 0.040(0.004) | |
| Spearman | 0.642(0.005) | 0.644(0.005) | 0.646(0.019) | |
| ROC-AUC | 0.885(0.008) | 0.885(0.005) | 0.888(0.005) | |
| Uracil | MCal | 0.225(0.013) | 0.519(0.054) | 0.636(0.084) |
| Max RCal | 0.811(0.014) | 0.283(0.046) | 0.385(0.069) | |
| MiscalArea | 0.062(0.003) | 0.150(0.015) | 0.182(0.023) | |
| Spearman | 0.666(0.006) | 0.658(0.014) | 0.654(0.031) | |
| ROC-AUC | 0.869(0.005) | 0.864(0.001) | 0.866(0.007) | |
| Toluene | MCal | 0.207(0.177) | 0.247(0.103) | 0.440(0.126) |
| Max RCal | 0.450(0.056) | 0.182(0.045) | 0.309(0.070) | |
| MiscalArea | 0.059(0.051) | 0.070(0.031) | 0.127(0.036) | |
| Spearman | 0.731(0.009) | 0.735(0.012) | 0.719(0.010) | |
| ROC-AUC | 0.889(0.002) | 0.889(0.007) | 0.884(0.002) |
Lower is better for MCal, Max RCal and MiscalArea; higher is better for Spearman and ROC-AUC. Bold = best in row.
The agreement is visible directly in the table. On aspirin and ethanol, where Gauss-D obtains the lowest MCal, it also has the lowest MiscalArea and the best or near-best Spearman/ROC-AUC. On uracil and toluene, where MER-D obtains the lowest MCal, it is best on all three Tan et al. diagnostics. Thus, these established metrics are broadly consistent with, rather than contradictory to, MCal.
Q1/Q2: Captions and PaiNN citation
RQ1/RQ2: We thank the reviewer for pointing out these typos. We will add the backbone name at the first relevant table caption and correct the missing PaiNN citation in the backbone paragraph.
Q3: Why does MACE underperform PaiNN/NequIP?
RQ3: We agree this needs clarification. We optimized NequIP and MACE, including using hidden irreps up to l=2; the reported settings are the best we identified. MACE achieves the highest QM7-X dipole accuracy only when paired with the MER loss: its best DP MAE is 0.0039 (MER-D), versus 0.0082 for its deterministic L1 backbone. Thus, the apparent backbone ranking depends substantially on the paired UE/loss function; it does not imply that MACE is intrinsically weaker. When manuscript revision is permitted, we will clarify the loss dependence in Implementation Details at PDF p.16, line 658: ``For QM7-X, MACE achieves its best dipole accuracy with the MER loss; L1 is used only for the deterministic NequIP/MACE backbones.''
Q4: Active-learning controls
RQ4: We have performed the requested random-acquisition control. At matched query budget, uncertainty-based acquisition remains better than random acquisition. The random-acquisition endpoint at the total label budget can serves as the fully supervised upper bound. When manuscript revision is permitted, we will add both the random-acquisition curve and this full-budget reference to Figure 2.
Questions
Thanks for the updated results, which I highly appreciate. A few questions:
- "At its fair setting (β=0.1), BLIP does not lead to any reported force-MAE". What prior probability did you use for this experiment? As I understand it from the BLIP paper, this could lead to substantially different results. The default seems to be around p=0.1-0.2.
- From the table,, it really seems dropout is needed in training; why is that so? I expect the regularizer to come from the prior choice and not from dropout, maybe the prior is too weak?
- Can you show the results of the active learning experiment? Maybe addind a table with few milestones if images are not possible to upload
- Rating
- 3/6
- Confidence
- 5/5
- Quality
- 2/4
- Clarity
- 3/4
- Significance
- 2/4
- Originality
- 2/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper introduces Equivariant Multivariate Evidential Regression (EMER), an uncertainty estimation framework designed for vector-valued physical properties such as molecular forces and dipole moments. The core contribution is a parameterization of the Normal-Inverse-Wishart prior's scale matrix (), which enforces rotational equivariance and positive definiteness. To overcome the inapplicability of standard scalar metrics to vector fields, the authors propose a multivariate calibration metric based on the coordinate-independent Mahalanobis distance. The framework is integrated into multiple equivariant graph neural networks (PaiNN, NequIP, MACE) and evaluated on MD17, QM7-X, and OC20 benchmarks.
Strengths and weaknesses
Here are, in my opinion, the major strengths and weaknesses of the proposed method:
Significance: Uncertainty quantification (UQ) for molecular forces remains a narrow niche within the machine-learned interatomic potential (MLIP) community. The reason is that most practitioners who are willing to use uncertainties simply perform uncertainty propagation in molecular dynamics using reweighting techniques from energy ensembles. In this sense, force UQ is not needed. For those seeking active learning strategies, uncertainties on local energies are often enough (and preferred, as they give a single and more interpretable scalar quantity). Unfortunately, this leaves force UQ without serious application potential. Dipoles are a more significant application, but the authors never explain how the covariance is aggregated over atoms for dipole predictions, making evaluation from a reviewer nearly impossible (as scaling of the variance/covariance with the size of the system has historically been a major footgun for per-structure properties in this field). Furthermore, I am concerned that the architectural complexity introduced by this framework will heavily hinder its actual adoption in practice (this is combined with the fact that the authors do not prove the need for such complexity, see below). The lack of machinery to take into account the conservative nature of forces (conservative forces are overwhelmingly used by practitioners) is also a significance concern (see below).
Originality: The primary theoretical claim is built around an equivariant parameterization of a covariance matrix. The fact that the covariance of a vector needs to transform as a Cartesian tensor cannot be framed as original, and constructing an identity plus low-rank matrix decomposition () to enforce positive definiteness and symmetry is clever, but it can also be considered standard linear algebra. The algorithmic novelty of this parameterization is therefore limited, although its application to forces/dipoles is, as far as I know, novel.
Quality: The framework relies on the machinery of Multivariate Evidential Regression (MER) with higher-order Normal-Inverse-Wishart priors. Crucially, the authors omit a simple baseline: a straightforward, single-pass mean-covariance network trained via the Gaussian (negative) log-likelihood. Without demonstrating that the more complex evidential prior outperforms a standard Gaussian covariance predictor, the core architectural overhead of EMER is not justified, and it potentially just increases complexity in a niche where the adoption barrier is high due to the scarcity of applications. Furthermore, in Appendix A.3, the authors justify abandoning conservative forces (energy gradients) on the OC20 dataset by claiming that computing the negative energy gradient is "computationally prohibitive" for larger graphs. This argument is false; backpropagation through a standard equivariant GNN to obtain conservative forces typically carries a predictable constant factor overhead (backward pass typically as expensive as the forward pass, resulting in only double the computational cost), which is standard practice across large-scale MLIP benchmarks. Still regarding conservative forces, the manuscript contains a fundamental omission regarding the interaction of its UQ heads and physical conservation laws. For the MD17 dataset, forces are properly computed as conservative fields via the negative gradient of the predicted energy scalar. Yet, the uncertainty parameters () are predicted via independent, unconstrained vector heads. In a valid physical system, force uncertainties are tied to the potential energy and cannot be treated as independent statistical degrees of freedom. The manuscript fails to account for or even acknowledge this limitation. (Minor point) In Question 7 of the NeurIPS Paper Checklist, the authors explicitly admit to omitting standard deviations or standard errors from their tables due to "space limitations". For a paper dedicated to the mathematical rigor of uncertainty estimation, I would at least expect to see the standard errors included in the appendix.
Clarity: The paper is structurally well-written and easy to follow. Unfortunately, the authors omitted their aggregation method for the covariance of dipole moments.
Questions
Here are some questions to the authors:
- How was constructed for dipoles?
- What applications would benefit from this method?
- Why did the authors jump to evidential regression instead of first testing a Gaussian mean-covariance estimator first?
- How could this method be extended to emerging non-equivariant / rotationally unconstrained architectures?
Limitations
The authors correctly discuss the representability issue in the paper, but they do not discuss the fact that their parametrization does not take into account the conservative nature of interatomic forces (i.e., that the forces need to be the negative gradient of the potential energy).
Final justification
The reasons for my score are summarized in my last comment to the Authors, reported here below.
My final assessment is therefore as follows: this paper tackles a problem (force uncertainties) whose relevance is already fading. Its technical limitations (non-conservative only, equivariant only) further reduce its scope, and the proposed solution might not be the optimal one (seeing the results, I am convinced that the mean-covariance baseline might have a better tradeoff between performance and complexity). Overall, I think that a paper in this space can be truly useful to the community only if 1) it solves uncertainties for forces with conservative constraints (which this work doesn't) and 2) it provides one simple and effective method for it (the authors propose their method, but a mean-covariance estimator might very well be the better solution). I will maintain my score.
In one sentence, the Authors try to solve a relatively niche problem (whose relevance is further fading), and they do not do so in a satisfactory way: 1) representability issues (undermining confidence that the method can actually capture arbitrary force uncertainty effects), 2) lack of analysis/method for conservative forces, 3) lack of applicability to unconstrained architectures, and 4) the unclear role of the more complex method the Authors advocate for over a simple Gaussian mean-covariance predictor are four reasons why this paper doesn't fully solve the problem and is, in my opinion, not yet suitable for publication in this conference.
Formatting concerns
No formatting concerns to raise.
5 comments
We thank the reviewer for the detailed technical critique. We address the main quality and significance concerns directly.
W1/R1. Gaussian mean-covariance baseline.
We agree this was the decisive missing control. We added a direct equivariant Gaussian mean-covariance predictor, Σ = exp(α)I + FF^T, trained with Gaussian NLL at matched PaiNN backbone. All other parameters, such as dropout ratio, are kept the same.
Table R1 gives the comparison on MD17-RotOOD. Lower is better.
| Mol | EMER-D F-MAE | Gauss-D F-MAE | EMER-D MCal | Gauss-D MCal | EMER-D Max RCal | Gauss-D Max RCal |
|---|---|---|---|---|---|---|
| Aspirin | 0.394(0.007) | 0.423(0.004) | 0.173(0.024) | 0.142(0.038) | 0.154(0.019) | 0.072(0.021) |
| Ethanol | 0.277(0.007) | 0.279(0.013) | 0.265(0.029) | 0.149(0.003) | 0.217(0.023) | 0.083(0.008) |
| MDA | 0.397(0.010) | 0.403(0.017) | 0.407(0.044) | 0.191(0.059) | 0.310(0.036) | 0.126(0.050) |
| Naphthalene | 0.162(0.006) | 0.171(0.012) | 0.147(0.028) | 0.428(0.091) | 0.156(0.041) | 0.355(0.069) |
| Salicylic acid | 0.269(0.005) | 0.305(0.013) | 0.221(0.063) | 0.385(0.123) | 0.120(0.040) | 0.259(0.082) |
| Toluene | 0.158(0.006) | 0.170(0.018) | 0.247(0.103) | 0.440(0.126) | 0.182(0.045) | 0.309(0.070) |
| Uracil | 0.193(0.004) | 0.233(0.004) | 0.519(0.054) | 0.636(0.084) | 0.283(0.046) | 0.385(0.069) |
The result is not a universal sweep, and we will state the scoped conclusion. First, compared with the Gaussian-NLL control, the NIW prior mainly improves accuracy: EMER-D gives lower force MAE on all 7 molecules and wins 18/21 paired-seed force-MAE comparisons. Second, the calibration effect is structure-dependent: EMER-D beats Gaussian-D on the rigid/aromatic RotOOD systems (naphthalene, salicylic acid, toluene, uracil), while Gaussian-D is better on the small/flexible cases and marginally better on aspirin MCal. Third, the Gaussian control itself still needs the SPD covariance form Σ = exp(α)I + FF^T; our additional no-isotropic-floor ablation (Σ = LL^T or Σ = LL^T + 1e-3I) was unstable. When manuscript revision is permitted, we will add a sentence to the MD17-RotOOD discussion at PDF p.8, line 308: a controlled Gaussian-NLL variant without the NIW prior shows that the NIW layer primarily helps force accuracy, while its calibration benefit is concentrated on systems with directional force uncertainty. The results of Gaussian NLL loss will be added as a new subsection in p19, line 714 Additional Results
W2/R2. Is this just dropout?
No. Dropout is shared across all "-D" variants and is used only during training as a regularizer, not as MC-dropout inference. At fixed dropout, EMER-D differs from MER-D in the covariance geometry. EMER-D wins Max RCal against MER-D on 20/21 seed-matched MD17-RotOOD runs. On the main anisotropic systems: naphthalene 0.156 vs 0.706, salicylic acid 0.120 vs 0.617. This isolates the effect of equivariance from the regularization effect of dropout.
W3/R3. Architectural complexity and necessity.
We agree that adoption requires a simple justification. The Gaussian control is a useful, strong alternative, but the NIW prior remains valuable: in Table R1, EMER-D gives better force accuracy than Gauss-D on all 7 molecules (18/21 paired-seed comparisons) while retaining the rotation-sensitive calibration gains on the rigid/aromatic systems. Its added complexity is minimal rather than architectural: in comparison to the Gaussian-NLL loss, it adds only the scalar evidential parameter (since we take ); both variants still require the same equivariant covariance head, including the learned isotropic scale and low-rank factor . The precise conclusion is therefore that the PD equivariant covariance construction is essential, while the NIW layer is a lightweight extension that provides the best overall force accuracy in our experiments.
Q1/RQ1. How was the dipole covariance constructed?
The dipole mean is sum-pooled, following the PaiNN-style readout at PDF p.17, line 662: μ = Σ_i ( μ_atom(v_i) + q_atom(s_i) r_i ). In contrast, the covariance head mean-pools its per-atom α_i and equivariant low-rank factors L_i, then forms Ψ = exp(α)I + LL^T. The dipole is therefore size-extensive, whereas its covariance is size-intensive.
This is suitable for the in-distribution QM7-X evaluation, but may not scale appropriately to size-OOD molecules. A sum-pooled or hybrid covariance readout should then be considered. When manuscript revision is permitted, we will add this clarification to Vector Output Head Details at PDF p.17, line 665.
W4/R4. Conservative-force uncertainty.
We agree that conservative forces are physically attractive. However, OC20 is a counter-intuitive setting in which direct force prediction is widely used and empirically strong. Kolluru et al. (arXiv:2206.02005) report that gradient-derived forces perform worse while increasing memory/time by 2--4×; Tran et al. (ACS Catalysis, doi:10.1021/acscatal.2c05426) report that direct force prediction tends to perform best despite breaking energy conservation. Our own batch-size-8 test shows the same trade-off:
| Direct force head | Forces = −∇ᵣE | Overhead | |
|---|---|---|---|
| Training step | 0.0468 s | 0.1363 s | 2.92× |
| Training peak GPU memory | 4.90 GiB | 11.68 GiB | 2.38× |
| Inference step | 0.0170 s | 0.0456 s | 2.68× |
| Inference peak GPU memory | 2.64 GiB | 6.22 GiB | 2.36× |
Importantly, this design choice does not affect the relative OC20 comparison in Table 10, because all methods use the same direct-force setting. To address the reviewer’s concern fully, we are still attempting a gradient-based force comparison under a lower training budget (10k training samples) and will do our best to obtain the result before the discussion closes.
W5/R5. OC20 "computationally prohibitive" wording.
We agree that "computationally prohibitive" was too strong. As detailed in W4/R4, direct force heads are an established, computationally flexible OC20 choice. When manuscript revision is permitted, we will replace the wording at PDF p.21, lines 746-756 with: "For OC20, we employ a direct force output head rather than computing forces as the negative energy gradient, because the latter incurs higher computational cost and has been reported to yield lower accuracy in this setting [refs]."
W6/R6. Standard deviations / statistical reporting.
We agree. All new results reported in this response already include mean(std) over seeds 1/10/100, and matched methods share the same seeds and splits. This enables paired comparisons rather than only independent averages. In Table R1, EMER-D has tighter MCal spread than Gauss-D on 6/7 molecules and tighter Max RCal spread on 5/7.
When manuscript revision is permitted, we will add std values for Tables 1, 2, 8, 9, and 10; if they exceed the available page width, we will provide additional tables in the Supplementary Material.
W7/R7. Significance and applications.
We thank the reviewer for pointing out that active learning of dipole moments is a potential application. We agree force UQ is narrower than energy UQ for many MLIP workflows, and we do not claim it replaces energy uncertainty. The target use case is when the vector itself drives the decision: force-based active learning, detecting unreliable force labels and adaptive simulation triggers. It can also support regional decisions. For example, in QM/MM MD, a user must decide which region requires an expensive QM calculation and which can be treated with a lower-cost model. A conventional global energy-UQ score gives only one scalar for the full system and cannot localize that decision without an additional local decomposition; per-atom force uncertainty can identify the unreliable region directly. This is the ``locality'' desideratum highlighted by Wollschläger et al. (ICML 2023, arXiv:2306.14916).
We also note that this direction is not limited to vectors. The same geometric-UQ principle can extend to higher-order tensor outputs, such as quadrupole moments and anisotropic polarizability. This is also supported by the recent ICML 2026 paper "Equivariant Covariance Tensors: Guaranteed SPD Uncertainty for Tensor-Valued Geometric Learning", which studies SPD equivariant uncertainty for tensor-valued geometric outputs. Extending our method to these tensor-property applications is a natural future direction.
Q2/RQ2. Extension to non-equivariant or rotationally unconstrained architectures.
This is an interesting question. If the backbone is not equivariant, our equivariant-uncertainty guarantee does not hold: a covariance head alone cannot recover a predictable transformation law from non-equivariant features. Evaluation with MCal/Max RCal remain practical empirical remedies, but they do not provide the same guarantee.
More broadly, multivariate probabilistic modeling remains an important direction even without an equivariant backbone. As the reviewer notes, energies and forces are correlated, and forces on different atoms are correlated. Standard MSE/L1 objectives, as well as our current EMER objective, do not model these cross-label dependencies: although EMER models the 3D covariance of each vector target, it treats energy--force and inter-atomic-force labels as conditionally independent. Extending MER/EMER to a joint, symmetry-consistent distribution over energies and all atomic forces is therefore an interesting future direction.
I thank the Authors for their detailed responses. Here are my considerations:
Conservative forces
I was aware that OC20 models generally obtain slightly better results with non-conservative forces; there is no need for the authors to attempt conservative training, especially if they lack the resources for it. I was mainly pushing back on the "computationally prohibitive" wording: literature work on the subject such as Bigi et al. 2025 (ICML) and Fu et al. 2025 (ICML) find that non-conservative forces are 2-3x cheaper (exactly as the Authors found). Unfortunately, the same works (and others) also find that non-conservative forces alone are not suitable for most applications of MLIPs. I consider the lack of conservative constraints a somewhat serious limitation of the work.
Error bars
I commend the Authors for providing statistical reporting, but I shall remind them that the reported errors should be standard errors, not standard deviations. Two methods are not equivalently good just because the dataset on which they are evaluated is noisy.
Overall significance (applications, dipoles, non-equivariant architectures, conservative forces, Gaussian baseline)
Unfortunately, as I motivated in my initial review, force uncertainties are not too relevant at the moment (MD observable uncertainties can be obtained from energy uncertainties, and practitioners do so), while the need of active learning using forces is more and more questionable now that universal models are available (no practitioners I know use active learning loops anymore, if they ever did). The only demonstration of non-force targets (dipoles) is affected by a serious extensivity flaw. Further limitations such as the treatment of non-equivariant architectures and conservative forces also affect the relevance of the paper for the community. The Authors claim that the mean-covariance baseline does slightly worse in the accuracy of the forces themselves, but in my opinion this could very well be an optimization/hyperparameter quirk.
My final assessment is therefore as follows: this paper tackles a problem (force uncertainties) whose relevance is already fading. Its technical limitations (non-conservative only, equivariant only) further reduce its scope, and the proposed solution might not be the optimal one (seeing the results, I am convinced that the mean-covariance baseline might have a better tradeoff between performance and complexity). Overall, I think that a paper in this space can be truly useful to the community only if 1) it solves uncertainties for forces with conservative constraints (which this work doesn't) and 2) it provides one simple and effective method for it (the authors propose their method, but a mean-covariance estimator might very well be the better solution). I will maintain my score.
- Rating
- 5/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 4/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper studies uncertainty estimation for vector-valued molecular properties such as forces and dipole moments. The key point is that not only the predicted vector mean, but also the predictive uncertainty distribution, should transform correctly under 3D rotations. The authors propose EMER, an equivariant multivariate evidential regression framework whose covariance parameterization is constructed to satisfy the SO(3) transformation law. They also introduce a Mahalanobis-distance-based calibration metric for multivariate vector uncertainty and evaluate the method on MD17, QM7-X, and OC20, including rotated-distribution settings designed to expose failures of non-equivariant uncertainty estimates.
Strengths and weaknesses
The paper addresses a real gap in molecular uncertainty estimation. SE(3)-equivariant models have become central in molecular modeling, but their uncertainty estimates are less well studied. Many equivariant models ensure that force predictions rotate correctly, but the associated uncertainty head can still output a covariance that does not transform as . In that sense, this is a timely contribution. The paper states the issue clearly and gives a covariance parameterization that enforces the right transformation law.
The rotated-OOD experiments are the most convincing part. They test the failure mode that matters here: a non-equivariant uncertainty estimate can look fine on aligned standard splits and then fail after a simple coordinate rotation. The MER/MER-Dropout comparison also makes the role of equivariance much cleaner than a comparison only against sampling baselines. Reporting MCal together with RCal and NLL is a good choice.
The main limitation is scope. Once the problem is written down, the covariance transformation law is basically forced. The contribution is the particular parameterization and the evidence that it helps in molecular vector uncertainty, not the idea that vector covariances should rotate. That is still a worthwhile contribution, but the paper should not oversell the conceptual step.
I also want a sharper interpretation of MCal. It is the right kind of metric for a multivariate vector distribution, but the paper should say more clearly when MCal should override marginal calibration metrics and when the two can disagree. The active learning experiment helps, but the broader downstream story is still thin: the paper shows that equivariant covariance matters under rotation; it is less clear how often this changes decisions in realistic molecular simulation or discovery workflows.
I am positive overall. The method is technically sound, the evaluation now targets the right failure mode, and the paper fills a specific but important hole in uncertainty estimation for molecular vector properties.
Questions
-
Interpreting MCal. The Mahalanobis calibration metric is natural for multivariate vector uncertainty, but the paper should make its interpretation clearer relative to RCal and NLL. In what cases should a practitioner trust MCal over marginal calibration, and when can the two disagree?
-
Equivariance vs. dropout regularization. The MER/MER-Dropout and EMER/EMER-Dropout comparisons are useful, but dropout still appears to be a major stabilizer. Can the authors clarify how much of the practical gain comes from the equivariant covariance parameterization versus dropout regularization?
-
Scope of RotOOD. The rotated-OOD setting is a good diagnostic, and recent work such as "Take Note: Your Molecular Dataset Is Probably Aligned" supports the concern that molecular datasets can have strong orientation bias. What part of the RotOOD analysis is new here beyond applying this dataset-alignment issue to uncertainty calibration, and how representative is RotOOD of real molecular dynamics, active learning, or force-field screening settings?
-
I am currently leaning positive. I would consider increasing my score if the rebuttal clarifies the points above, especially the relationship between MCal and standard calibration metrics and the role of the equivariant covariance parameterization beyond the rotated diagnostic.
Limitations
yes
Final justification
I recommend acceptance and have increased my score from 4 to 5.
The rebuttal addresses my main concerns about the interpretation of MCal, the role of dropout versus equivariant covariance, and the scope of RotOOD. The added Gaussian-NLL control is particularly helpful: it shows that the NIW layer mainly improves force accuracy, while dropout and equivariant covariance contribute differently to calibration. The additional clarification of dipole aggregation, active learning, statistical reporting, and OC20 computational cost further strengthens the response.
Some limitations remain, including structure-dependent calibration gains, open questions about size-OOD covariance scaling, and the lack of conservative force uncertainty. However, I view these as limitations of scope rather than fundamental flaws. Overall, the rebuttal provides sufficient support for the paper’s central contribution, and the reasons to accept outweigh the remaining concerns.
Formatting concerns
No major formatting concern.
2 comments
Rebuttal
We thank the reviewer for the constructive reading. We address the main clarification requests below and state where the manuscript will be revised when revision is permitted.
W1/R1. Novelty framing.
We agree that the covariance transformation law itself is not the novelty. Once vector uncertainty is posed correctly, the tensor transformation rule is forced. When manuscript revision is permitted, we will combine the current contribution statements on PDF pp.2-3, lines 77-80 into one clearer contribution: we propose a novel equivariant covariance parameterization for vector uncertainty that satisfies the required equivariance transformation law while remaining positive-definite and practically identifiable.
Q1/RQ1. Interpreting MCal relative to RCal/NLL.
They answer different questions. MCal evaluates the full vector uncertainty ellipsoid through the Mahalanobis distance, so its meaning is invariant to the coordinate frame. RCal and per-axis NLL evaluate scalar marginals; they are useful, but frame-dependent.
The two can disagree when a covariance has roughly the right total scale but the wrong directional shape. This is exactly the failure mode of a non-equivariant covariance. On naphthalene RotOOD in the submitted Table 1:
| Method | MCal | Max RCal |
|---|---|---|
| MER-D, non-equivariant | 0.201 | 0.706 |
| EMER-D, equivariant | 0.147 | 0.156 |
Both metrics favor EMER-D on this molecule, but they diagnose different aspects of the improvement: MCal improves from 0.201 to 0.147, while Max RCal improves much more sharply from 0.706 to 0.156. Across all 7 MD17-RotOOD molecules in the submitted Table 1, EMER-D improves Max RCal over MER-D, showing that the rotation-sensitive marginal metric exposes the covariance-orientation failure most clearly.
When manuscript revision is permitted, we will add this guidance in Appendix "Evaluation Metrics" at PDF p.19 line 705: MCal should be the primary coordinate-independent vector calibration metric, but it should be reported with Max RCal/NLL to verify that the uncertainty ellipsoid is not only correctly scaled but also correctly oriented.
Q2/RQ2. Equivariance versus dropout regularization.
Dropout is a shared training-time regularizer in all "-D" variants; it is not MC-dropout at inference. Thus the matched MER-D vs EMER-D comparison isolates the equivariant covariance. In the submitted Table 1, at fixed dropout EMER-D reduces Max RCal from 0.706 to 0.156 on naphthalene, 0.617 to 0.120 on salicylic acid, 0.811 to 0.283 on uracil, and 0.450 to 0.182 on toluene. These are the anisotropic/ring systems where the covariance direction matters most.
The key same-dropout evidence from submitted Table 1 is shown below (MD17-RotOOD; lower is better):
| Mol | Method | Force MAE | MCal | Max RCal |
|---|---|---|---|---|
| Naphthalene | MER-D | 0.1561 | 0.2013 | 0.7058 |
| EMER-D | 0.1616 | 0.1472 | 0.1564 | |
| Salicylic acid | MER-D | 0.2893 | 0.1860 | 0.6172 |
| EMER-D | 0.2687 | 0.2211 | 0.1197 | |
| Uracil | MER-D | 0.2061 | 0.2250 | 0.8112 |
| EMER-D | 0.1932 | 0.5193 | 0.2832 | |
| Toluene | MER-D | 0.1553 | 0.2068 | 0.4495 |
| EMER-D | 0.1583 | 0.2465 | 0.1816 |
This is the cleanest comparison for the reviewer's question because both models use the same dropout regularization, seeds, splits, backbone, and budget. The remaining difference is whether the covariance is equivariant.
Q3/RQ3. Scope of RotOOD.
RotOOD is a controlled diagnostic, not a claim that real deployment consists of one fixed rotation. Its purpose is to hold the molecule and force field fixed while changing only the coordinate frame. This exposes a specific issue: a non-equivariant uncertainty head can appear calibrated on aligned train/test splits because both share the same orientation bias, yet fail when queried in another frame. The new part here is the uncertainty-calibration consequence of dataset alignment, not the existence of alignment bias itself.
For how often this can matter, we will be concrete rather than expansive. The recent ICLR 2026 paper "Take Note: Your Molecular Dataset Is Probably Aligned" documents that common molecular datasets can have orientation bias and that models can exploit it. Our setting is narrower but consistent with this concern: in our MD17 study, two molecules, Naphthalene and Uracil, already exhibit predominantly planar force-label distributions, as noted in the current manuscript. Thus RotOOD is not meant to simulate every deployment distribution, but it targets a real dataset property that can affect vector uncertainty evaluation.
For deployment, the relevance is that MD trajectories, generated conformers, screening poses, and active-learning candidates are not guaranteed to be presented in the training frame. In those settings an uncertainty threshold should not depend on arbitrary global orientation.
When manuscript revision is permitted, we will revise the RotOOD construction paragraph in Experiments at PDF p.8, lines 289-290 as follows: such orientation-bias effects have been specifically discussed in the recent work [Ref "Take Note: Your Molecular Dataset Is Probably Aligned"]; they also occur in the MD17 dataset used here, where Naphthalene and Uracil exhibit predominantly planar force-label distributions.
Q4/RQ4. Role of equivariant covariance beyond the rotated diagnostic.
The role is not only "better under a synthetic rotation." Once the target is a vector, the full predictive distribution should transform consistently: the mean rotates as a vector and the covariance rotates as a rank-2 tensor. Otherwise the same molecular state can receive different confidence regions, likelihoods, or acquisition priorities solely because the Cartesian axes changed. RotOOD is therefore a controlled test of a probabilistic consistency requirement, not the only motivation for equivariance.
This principle is also emerging in recent geometric-UQ work: the ICML 2026 paper "Equivariant Covariance Tensors: Guaranteed SPD Uncertainty for Tensor-Valued Geometric Learning" similarly treats symmetry-preserving covariance and positive-definiteness as requirements for uncertainty on geometric outputs, though for tensor-valued rather than vector-valued targets.
Our contribution is to make this requirement trainable with an anisotropic SPD covariance. In Σ = exp(α)I + FF^T, the scalar term provides a positive isotropic floor, while FF^T provides geometry-dependent directional uncertainty.
Together, these clarifications show that RotOOD is a controlled diagnostic for a real probabilistic consistency issue: vector uncertainty should rotate with the vector target, and our parameterization makes this requirement trainable and stable.
Thanks for the detailed response and the additional experiments. I think the rebuttal addresses most of the concerns I raised.
The clarification of MCal and the matched MER-D/EMER-D comparison make the role of the equivariant covariance parameterization much clearer. The Gaussian-NLL baseline is also helpful for separating the contributions of the NIW layer, dropout, and covariance geometry. The calibration gains over Gauss-D are not uniform, but I appreciate that the authors now make this distinction more explicit.
The clarification of RotOOD as a controlled diagnostic, rather than a complete model of every deployment setting, also seems appropriate.
Overall, I am more positive about the paper after the rebuttal and am leaning toward increasing my score from 4 to 5.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
We thank the AC. We summarize the four decisive items here.
(1) Equivariant Gaussian NLL baseline — isolating the evidential layer
We added the requested Gaussian control, (Σ=exp(α)I+FF⊤), trained with Gaussian NLL and no NIW prior, using the same backbone, dropout, seeds.
The comparisons suggest a clear role split: the NIW prior mainly improves force accuracy, dropout mainly improves overall calibration, and the equivariant covariance mainly improves rotation-sensitive dimension-wise calibration and NLL.
Importantly, Gauss-D still requires the SPD form (Σ=exp(α)I+FF⊤). Naive low-rank alternatives, (LL⊤) and (LL⊤+10−3I), were unstable during training. Thus, the learned isotropic floor is load-bearing even without the NIW prior.
(2) Per-seed dispersion
Table R1 in our rebuttal to Reviewer pxhK reports mean (std) over seeds 1/10/100, with matched methods using identical splits and seeds. EMER-D has a smaller standard deviation than Gauss-D on 6/7 molecules for both MCal and Max RCal. We will add standard deviations to all main and supplementary result tables.
(3) Dipole covariance aggregation
For the dipole covariance matrix, we simply mean-pool the per-atom (αi) and (Li), and construct $ \Psi=\operatorname{exp}(\alpha)I+LL^\top . $
This preserves the required equivariance of the covariance. How the covariance should scale with molecular size remains an open modeling question: simple sum-pooling is not obviously preferable, since a large but highly symmetric molecule can still have a near-zero dipole moment, so covariance need not scale directly with atom count.
Importantly, this issue primarily arises under size-OOD extrapolation. QM7-X is evaluated within a limited in-distribution molecular-size range, so it does not affect the conclusions reported here. We will clarify the aggregation rule and note size-OOD covariance scaling as an open question in the revised manuscript.
(4) OC20 direct-force vs. energy-gradient compute
We would like to note that direct-force prediction on OC20 is a somewhat counterintuitive but established community choice. Kolluru et al. (arXiv:2206.02005), from the OCP team, report that gradient-derived forces perform worse than direct-force prediction while increasing memory and computational cost by 2–4×. Tran et al. (ACS Catalysis, doi:10.1021/acscatal.2c05426) similarly report that “direct force predictions tend to perform the best despite breaking energy conservation.”
Nevertheless, we addressed this question empirically. Gradient-force results using the original OC20 setting with 100k training samples and seeds 1/10/100 are now provided in Table R3 of our response to Reviewer qrbk. These results confirm that EMER remains compatible with conservative force prediction.
We have addressed all reviewer questions in our responses above and summarized here the four decisive items highlighted in the meta-review. We thank the AC and reviewers for their constructive feedback and hope these additional experiments and clarifications resolve the main concerns and make the scope and contribution of the paper clearer.