SAFE-SVD: Sensitivity-Aware Fidelity-Enforcing SVD for Physics Foundation Models
Chengjie Hong, Feixiang He, Yiheng Zeng, Lulu Kang, He Wang
NeurIPS 2026
TL;DR. We propose the first SVD-based model compression method for Physics Foundational Models
Abstract. We propose a new method for compressing physics foundation models (PFMs) which is a new trend in AI for Science. While model compression is essential for reducing memory use and accelerating inference in large foundation models, it remains under-explored for PFMs, where preserving physical fidelity is crucial. The challenge lies in the functional nature of physics data, where partial deriva- tives encode spatiotemporal dynamics and exhibit high sensitivity to compression. Conventional compression methods ignore this structure, often causing severe performance degradation or failure. To address this, we introduce a sensitivity- aware fidelity-enforcing compression framework that explicitly models loss-aware layer sensitivity in the output function space during compression. This provides a new route to compressing scientific foundation models while preserving accuracy and physical fidelity. Experiments show substantial gains over existing methods across multiple models and datasets, achieving significantly higher compression ratios while maintaining accuracy, in some cases by orders of magnitude. More broadly, the work potentially leads to a new subfield of efficient, deployable, and sustainable scientific foundation models in AI for Science. The code is available at: https://github.com/realcrane/SafeSVD.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:45 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
The paper presents a technically interesting post-training SVD compression method for physics foundation models, with broad evaluation across three model families and multiple PDE settings. I view the submission as needing clarification, with the following prioritized issues.
-
Reliability of the central empirical results. As raised by Reviewers SeTW and XM4x, SAFE-SVD shows almost no degradation in several Poseidon settings while competing methods degrade by orders of magnitude. Please provide raw, unrounded losses in addition to relative percentages; clearly confirm calibration/test separation; explain the baseline adaptations and the differing final model sizes; and state whether the results are deterministic or sensitive to calibration-subset selection. This is important for excluding metric-scaling or evaluation artifacts.
-
Meaning of “physical fidelity.” As noted by Reviewer XM4x, the method uses a Sobolev-augmented loss for sensitivity estimation and is then evaluated substantially through Sobolev error. Independent constraint-based evidence is mainly provided for incompressible Navier–Stokes. Please clarify which claims are supported across the other PDE families and narrow “physical fidelity” to derivative fidelity where conservation or constraint metrics are unavailable.
-
Theory–implementation alignment. Please address Reviewer SeTW’s concern by distinguishing the quadratic activation-space surrogate used for the SVD derivation from the L1 Sobolev loss used to compute sensitivity. Also state the assumptions underlying the Fisher/Gauss–Newton approximation and omission of the first-order Taylor term.
-
Compression definition. As requested by Reviewer pbxu, define precisely what ratios such as 0.2, 0.4, and 0.6 retain, explain why model sizes differ across methods at the same reported ratio, and distinguish parameter reduction from demonstrated memory or latency improvements.
Minor presentation inconsistencies are not decision-critical, and extensive new experiments are not required during rebuttal; clarification using existing results or appropriately narrowed claims would suffice. If these issues are resolved convincingly, I would be inclined to support acceptance, subject to the final discussion.
Final justification
After considering the rebuttal and reviewer discussion, I recommend to accept. The paper addresses an underexplored and practically relevant problem with a technically sound method and broad evaluation across multiple PFM families and PDE settings. The rebuttal substantially resolves the main concerns: the corrected multi-run and calibration analyses continue to support the empirical gains, while the additional physical-consistency evaluations and clarifications strengthen the central claims. Overall, the remaining limitations do not outweigh the technical contribution and empirical evidence.
Read meta-review
Meta-review
The paper presents a technically interesting post-training SVD compression method for physics foundation models, with broad evaluation across three model families and multiple PDE settings. I view the submission as needing clarification, with the following prioritized issues.
-
Reliability of the central empirical results. As raised by Reviewers SeTW and XM4x, SAFE-SVD shows almost no degradation in several Poseidon settings while competing methods degrade by orders of magnitude. Please provide raw, unrounded losses in addition to relative percentages; clearly confirm calibration/test separation; explain the baseline adaptations and the differing final model sizes; and state whether the results are deterministic or sensitive to calibration-subset selection. This is important for excluding metric-scaling or evaluation artifacts.
-
Meaning of “physical fidelity.” As noted by Reviewer XM4x, the method uses a Sobolev-augmented loss for sensitivity estimation and is then evaluated substantially through Sobolev error. Independent constraint-based evidence is mainly provided for incompressible Navier–Stokes. Please clarify which claims are supported across the other PDE families and narrow “physical fidelity” to derivative fidelity where conservation or constraint metrics are unavailable.
-
Theory–implementation alignment. Please address Reviewer SeTW’s concern by distinguishing the quadratic activation-space surrogate used for the SVD derivation from the L1 Sobolev loss used to compute sensitivity. Also state the assumptions underlying the Fisher/Gauss–Newton approximation and omission of the first-order Taylor term.
-
Compression definition. As requested by Reviewer pbxu, define precisely what ratios such as 0.2, 0.4, and 0.6 retain, explain why model sizes differ across methods at the same reported ratio, and distinguish parameter reduction from demonstrated memory or latency improvements.
Minor presentation inconsistencies are not decision-critical, and extensive new experiments are not required during rebuttal; clarification using existing results or appropriately narrowed claims would suffice. If these issues are resolved convincingly, I would be inclined to support acceptance, subject to the final discussion.
Final justification
After considering the rebuttal and reviewer discussion, I recommend to accept. The paper addresses an underexplored and practically relevant problem with a technically sound method and broad evaluation across multiple PFM families and PDE settings. The rebuttal substantially resolves the main concerns: the corrected multi-run and calibration analyses continue to support the empirical gains, while the additional physical-consistency evaluations and clarifications strengthen the central claims. Overall, the remaining limitations do not outweigh the technical contribution and empirical evidence.
1 comment
- Rating
- 5/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 4/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper introduces SAFE-SVD, a post-training, physics-aware SVD compression method for physics foundation models (PFMs) that estimates layer sensitivity from a Sobolev-augmented loss, compresses layers sequentially to handle cross-layer error propagation, and allocates ranks globally with a greedy benefit–cost score. The authors report that it substantially outperforms existing SVD baselines, retaining both predictive accuracy and physical fidelity across several PFMs and PDE families.
Strengths and weaknesses
Strengths
- The problem is timely and clearly motivated. The compression of PFMs is still under-explored, and the paper makes a convincing case that derivative-level and constraint-related physical fidelity matters beyond pointwise prediction accuracy.
- The paper is well-structured and easy to follow.
- The empirical evaluation is broad and generally strong, comparing against several SVD-based baselines across multiple PFMs, PDE families, compression ratios, and physics-aware metrics.
Weaknesses
-
W1. None of the results report error bars, confidence intervals, or variation across calibration subsets, which makes it difficult to judge the significance of close comparisons. Since SAFE-SVD relies on calibration data to estimate activation statistics and sensitivity matrices, reporting variability across calibration subsets would strengthen the empirical claims.
-
W2. The central claim is preservation of physical fidelity, but much of the supporting evidence rests on the Sobolev loss, which is closely aligned with the Sobolev-augmented loss used to construct the sensitivity-aware objective. This shows that the method preserves the derivative-matching structure it is designed to preserve, but it provides limited independent evidence of physical correctness. The more direct constraint-based check, the divergence-free error, is reported only for incompressible Navier-Stokes. The authors should report constraint- or conservation-based metrics for other PDE families, such as energy, momentum, or mass conservation where applicable, to provide evidence of physical fidelity that is independent of the Sobolev metric.
Questions
See above.
Limitations
Yes
Final justification
Both weaknesses are resolved and I keep my rating of 5 (Accept).
Formatting concerns
N/A
5 comments
Rebuttal
We thank the reviewers for their helpful and constructive feedback. Our responses are provided below.
W1: report variability across calibration subsets.
We provide new experiments on 5 calibration subsets which are randomly sampled from the training data. The results indicate that our method is not sensitive to calibration subset. The overall performance remains consistent with our experiments in main text. We report mean ± standard deviation across compressed models.
Table: Poseidon
| Ratio | Method | Size | NS-PwC: Base Loss ↓ | NS-PwC: Sobolev ↓ | NS-PwC: Div-Free ↓ | NS-PwC: Vorticity ↓ | CE-RM: Base Loss ↓ | CE-RM: Sobolev ↓ | Wave-Gauss: Base Loss ↓ | Wave-Gauss: Sobolev ↓ |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.0 | Origin | 628.6M | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% |
| 0.8 | Ours | 503.0M | 0.02% ± 0.00% | 0.00% ± 0.00% | 0.00% ± 0.00% | 0.00% ± 0.00% | 0.00% ± 0.00% | 0.00% ± 0.00% | 0.01% ± 0.01% | 0.00% ± 0.00% |
| 0.6 | Ours | 377.5M | 0.00% ± 0.01% | 0.01% ± 0.00% | 0.00% ± 0.00% | 0.01% ± 0.00% | 0.00% ± 0.00% | 0.00% ± 0.00% | 0.03% ± 0.03% | 0.07% ± 0.06% |
| 0.4 | Ours | 251.9M | 0.22% ± 0.01% | 0.09% ± 0.00% | 0.02% ± 0.00% | 0.12% ± 0.01% | 0.01% ± 0.00% | 0.05% ± 0.00% | 0.04% ± 0.02% | 0.48% ± 0.28% |
| 0.2 | Ours | 126.3M | 3.93% ± 1.43% | 4.13% ± 2.45% | 2.17% ± 0.54% | 1.77% ± 0.47% | 0.20% ± 0.02% | 1.32% ± 0.46% | 1.02% ± 0.30% | 152.1% ± 32.21% |
Table: VICON
| Ratio | Method | Size | NS-2D: Base Loss ↓ | NS-2D: Sobolev ↓ | NS-2D: Div-Free ↓ | NS-2D: Vorticity ↓ | Comp-2D: Base Loss ↓ | Comp-2D: Sobolev ↓ | Euler-2D: Base Loss ↓ | Euler-2D: Sobolev ↓ |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.0 | Origin | 87.8M | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% |
| 0.8 | Ours | 70.3M | 2.49% ± 1.58% | 0.64% ± 0.46% | 0.16% ± 0.09% | 0.61% ± 0.34% | 2.35% ± 1.38% | 0.94% ± 0.51% | 3.39% ± 2.61% | 20.13% ± 12.71% |
| 0.6 | Ours | 52.8M | 2.20% ± 1.71% | 0.40% ± 0.49% | 0.34% ± 0.09% | 1.30% ± 0.45% | 17.09% ± 3.57% | 7.40% ± 0.66% | 7.10% ± 4.20% | 14.17% ± 14.16% |
| 0.4 | Ours | 35.3M | 20.57% ± 1.87% | 3.20% ± 0.46% | 0.98% ± 0.13% | 8.51% ± 0.59% | 68.73% ± 2.40% | 24.44% ± 1.17% | 28.48% ± 4.61% | 17.98% ± 12.82% |
| 0.2 | Ours | 17.8M | 236.1% ± 4.17% | 20.21% ± 0.42% | 7.31% ± 0.17% | 65.38% ± 0.90% | 973.3% ± 37.64% | 101.9% ± 3.20% | 261.4% ± 10.65% | 13.82% ± 5.34% |
Table: MPP
| Ratio | Method | Size | IncompNS: Base Loss ↓ | IncompNS: Sobolev ↓ | IncompNS: Div-Free ↓ | IncompNS: Vorticity ↓ | CompNS: Base Loss ↓ | CompNS: Sobolev ↓ | DiffRe-2D: Base Loss ↓ | DiffRe-2D: Sobolev ↓ | SWE: Base Loss ↓ | SWE: Sobolev ↓ |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.0 | Origin | 407.1M | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% |
| 0.8 | Ours | 366.8M | 15.59% ± 1.25% | 1.52% ± 0.16% | 0.06% ± 0.03% | 2.69% ± 0.36% | 0.19% ± 0.11% | 0.07% ± 0.02% | 3.53% ± 0.83% | 0.87% ± 0.07% | 16.15% ± 2.50% | 2.31% ± 0.30% |
| 0.6 | Ours | 326.5M | 90.40% ± 3.13% | 8.87% ± 0.68% | 0.22% ± 0.06% | 16.63% ± 0.87% | 1.65% ± 0.21% | 0.51% ± 0.07% | 14.96% ± 2.92% | 3.20% ± 0.18% | 67.86% ± 6.03% | 9.45% ± 0.75% |
| 0.4 | Ours | 286.3M | 407.0% ± 9.32% | 36.15% ± 2.96% | 0.64% ± 0.16% | 64.71% ± 3.52% | 12.60% ± 0.94% | 2.74% ± 0.26% | 63.79% ± 8.49% | 11.25% ± 0.53% | 264.4% ± 21.07% | 35.33% ± 1.97% |
| 0.2 | Ours | 246.0M | 1918% ± 102.2% | 131.4% ± 8.86% | 2.08% ± 0.26% | 197.5% ± 9.06% | 93.72% ± 4.97% | 12.38% ± 0.22% | 318.0% ± 31.47% | 42.95% ± 2.19% | 1225% ± 88.25% | 131.5% ± 4.03% |
W2: Report constraint- or conservation-based metrics for other PDE families.
We additionally report PDE-specific physical-consistency metrics, since different PDEs describe different physical scenarios. Specifically, for CE-RM, we evaluate mass, momentum, and total-energy conservation metrics. For Wave-Gauss, the wave-speed field is time-invariant, as specified in Poseidon. We therefore report the following constraint-based metric
Table: Poseidon
| Ratio | Method | Size | CE-RM: Mass ↓ | CE-RM: Momentum ↓ | CE-RM: Energy ↓ | Wave-Gauss: Speed ↓ |
|---|---|---|---|---|---|---|
| 1.0 | Origin | 628.6M | 0.00% | 0.00% | 0.00% | 0.00% |
| 0.6 | ASVD | 377.1M | 70.62% | 61.21% | 67.38% | 2093% |
| 0.6 | FWSVD | 377.1M | 66.91% | 59.12% | 64.05% | 602.6% |
| 0.6 | SVD-LLM V2 | 420.0M | 72.16% | 55.35% | 69.97% | 1337% |
| 0.6 | Dobi-SVD | 378.7M | 74.70% | 16.49% | 73.50% | 1538% |
| 0.6 | SAES-SVD | 377.1M | 45.07% | 34.93% | 44.02% | 1713% |
| 0.6 | Ours | 377.5M | 0.00% | 0.00% | 0.00% | 0.00% |
| 0.4 | ASVD | 251.5M | 71.68% | 55.09% | 68.56% | 3813% |
| 0.4 | FWSVD | 251.5M | 59.17% | 35.82% | 53.31% | 967.2% |
| 0.4 | SVD-LLM V2 | 342.5M | 45.64% | 14.00% | 41.66% | 3692% |
| 0.4 | Dobi-SVD | 252.6M | 70.09% | 24.94% | 65.65% | 1886% |
| 0.4 | SAES-SVD | 251.5M | 49.01% | 34.17% | 46.93% | 1947% |
| 0.4 | Ours | 251.9M | 0.00% | 0.01% | 0.01% | 0.26% |
| 0.2 | ASVD | 125.6M | 58.53% | 57.60% | 53.09% | 3347% |
| 0.2 | FWSVD | 125.9M | 48.62% | 93.66% | 43.75% | 2457% |
| 0.2 | SVD-LLM V2 | 313.5M | 35.33% | 35.92% | 34.41% | 4677% |
| 0.2 | Dobi-SVD | 127.0M | 69.53% | 36.65% | 62.92% | 3257% |
| 0.2 | SAES-SVD | 125.9M | 55.31% | 33.72% | 51.94% | 2159% |
| 0.2 | Ours | 126.3M | 0.72% | 0.65% | 0.86% | 96.47% |
Dear Reviewers,
Thank you for your time and effort throughout the review process.
This is a kind reminder that the author–reviewer discussion phase will conclude on August 3. We encourage you to engage with the authors’ rebuttals at your earliest convenience.
Best,
ACs
In your comments on the variability of the experimental results on the choice of calibration datasets (W1), we initially showed them in the rebuttal above. However, later we found code version for experiments on variability was different from the one we used in the main paper. We apologize. We have re-run the experiments with more random seeds. Now we have a total of 11 results for each model including the original one in the main paper. We show them here. For reproducibility, we will open-source our code upon acceptance.
All Poseidon results in the main paper fall into the ranges of the new results. There are a few exceptions in MPP and VICON results with small differences, such as MPP IncompNS Sobolev loss at ratio 0.2 and Div-Free at ratio 0.8; VICON NS-2D Base Loss and Vorticity at ratio 0.8. We will update the results in the final paper if accepted. We sincerely thank the reviewer for helping us to improve the experiments, which now conclusively show that SAFE-SVD reliably outperforms the baseline methods.
Table: Poseidon
| Ratio | Method | Size | NS-PwC Base Loss ↓ | NS-PwC Sobolev ↓ | NS-PwC Div-Free ↓ | NS-PwC Vorticity ↓ | CE-RM Base Loss ↓ | CE-RM Sobolev ↓ | Wave-Gauss Base Loss ↓ | Wave-Gauss Sobolev ↓ |
|---|---|---|---|---|---|---|---|---|---|---|
| 0.8 | Ours | 503.0M | 0.000325% ± 0.000022% | 0.000056% ± 0.000005% | 0.000079% ± 0.000006% | 0.000063% ± 0.000009% | 0.000009% ± 0.000000% | 0.000024% ± 0.000001% | 0.000130% ± 0.000009% | 0.000028% ± 0.000001% |
| 0.6 | Ours | 377.5M | 0.004377% ± 0.000993% | 0.010893% ± 0.003671% | 0.002497% ± 0.000175% | 0.011064% ± 0.000611% | 0.003824% ± 0.000264% | 0.002570% ± 0.000152% | 0.002638% ± 0.000182% | 0.006615% ± 0.000309% |
| 0.4 | Ours | 251.9M | 0.272097% ± 0.018793% | 0.082933% ± 0.009439% | 0.031330% ± 0.001561% | 0.167792% ± 0.008715% | 0.012852% ± 0.000888% | 0.046100% ± 0.002722% | 0.042955% ± 0.002967% | 0.389128% ± 0.018195% |
| 0.2 | Ours | 126.3M | 2.630446% ± 0.173058% | 1.817209% ± 0.179115% | 0.491240% ± 0.034353% | 1.324470% ± 0.091498% | 0.102373% ± 0.006863% | 0.992629% ± 0.079074% | 0.696032% ± 0.048073% | 147.252537% ± 7.164102% |
Table: VICON
| Ratio | Method | Size | NS-2D Base Loss ↓ | NS-2D Sobolev ↓ | NS-2D Div-Free ↓ | NS-2D Vorticity ↓ | Comp-2D Base Loss ↓ | Comp-2D Sobolev ↓ | Euler-2D Base Loss ↓ | Euler-2D Sobolev ↓ |
|---|---|---|---|---|---|---|---|---|---|---|
| 0.8 | Ours* | 70.3M | 2.32% ± 1.50% | 0.61% ± 0.44% | 0.17% ± 0.09% | 0.55% ± 0.37% | 2.20% ± 1.34% | 0.91% ± 0.48% | 3.15% ± 2.50% | 18.37% ± 12.94% |
| 0.6 | Ours* | 52.8M | 2.09% ± 1.58% | 0.38% ± 0.47% | 0.37% ± 0.14% | 1.21% ± 0.54% | 17.10% ± 3.59% | 7.74% ± 1.69% | 7.19% ± 3.63% | 15.51% ± 13.43% |
| 0.4 | Ours* | 35.3M | 20.64% ± 1.62% | 3.23% ± 0.53% | 1.01% ± 0.14% | 8.47% ± 0.62% | 73.42% ± 7.41% | 25.93% ± 2.38% | 28.07% ± 3.71% | 16.69% ± 12.52% |
| 0.2 | Ours* | 17.8M | 239.0% ± 6.25% | 20.41% ± 0.61% | 7.43% ± 0.31% | 66.07% ± 1.45% | 984.0% ± 79.79% | 104.2% ± 6.49% | 257.2% ± 10.65% | 14.34% ± 4.83% |
Table: MPP
| Ratio | Method | Size | IncompNS Base Loss ↓ | IncompNS Sobolev ↓ | IncompNS Div-Free ↓ | IncompNS Vorticity ↓ | CompNS Base Loss ↓ | CompNS Sobolev ↓ | DiffRe-2D Base Loss ↓ | DiffRe-2D Sobolev ↓ | SWE Base Loss ↓ | SWE Sobolev ↓ |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 0.8 | Ours* | 366.8M | 15.45% ± 1.91% | 1.54% ± 0.20% | 0.06% ± 0.02% | 2.81% ± 0.32% | 0.15% ± 0.14% | 0.08% ± 0.02% | 3.73% ± 0.69% | 0.89% ± 0.08% | 18.78% ± 2.08% | 2.38% ± 0.30% |
| 0.6 | Ours* | 326.5M | 90.86% ± 4.33% | 8.88% ± 0.61% | 0.22% ± 0.07% | 17.06% ± 0.99% | 1.89% ± 0.46% | 0.55% ± 0.11% | 15.70% ± 2.19% | 3.31% ± 0.21% | 71.20% ± 9.84% | 9.76% ± 0.98% |
| 0.4 | Ours* | 286.3M | 407.5% ± 10.54% | 36.07% ± 2.19% | 0.64% ± 0.14% | 66.54% ± 4.12% | 13.20% ± 1.89% | 2.84% ± 0.30% | 65.43% ± 6.50% | 11.59% ± 0.68% | 277.3% ± 24.42% | 36.00% ± 1.83% |
| 0.2 | Ours* | 246.0M | 1882% ± 104.6% | 129.9% ± 7.17% | 2.05% ± 0.22% | 197.5% ± 9.93% | 98.35% ± 10.17% | 12.74% ± 0.70% | 318.1% ± 25.30% | 43.50% ± 1.71% | 1246% ± 89.80% | 131.5% ± 5.79% |
- Rating
- 4/6
- Confidence
- 2/5
- Quality
- 4/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper introduces SAFE-SVD which is an SVD based method for post-training model compression for physics foundation models. The main idea of the method is to make the model compression method physics-aware to preserve the physics properties that the model has learned. The method achieves this by defining a loss-aware layer sensitivity, combining the base loss with a Sobolev-space loss and using Fisher Information Matrix. The method also includes modeling cross-layer error propagation and a rank-allocation algorithm to keep the learned physics in the model. SAFE-SVD has been evaluated on Poseidon, VICON and MPP pre-trained models on different PDEs such as Navier-Stokes, Euler, wave, diffusion-reaction and is also compared with some of the SVD-baselines such as FWSVD, ASVD, Dobi-SVD and SAES-SVD. The results show that their method outperforms the baselines in almost all the PDEs and pre-trained models.
Strengths and weaknesses
Strengths
- Compression of physics foundation models is not a very explored domain and the observation that conventional SVD-based compression methods do not necessarily preserve the learned physics properties is a good motivation.
- Mathematical derivations connecting loss-aware objective to low-rank problems is well explained and easy to follow.
- The paper evaluates on 3 models, i.e., Poseidon, VICON and MPP and on different PDE families. The results on compression ratios with base loss and Sobolev loss and some PDE-specific metrics are promising. The rollout comparisons in the figures of the main paper are an interesting result and help understand how they keep the physical properties and not just metric values.
- The method outperforms in the case of PDEs such as Navier-Stokes, Euler and wave equations compared to almost all the baselines and has low degradation even under high compressions.
Weaknesses
- On Poseidon in Table 2 and 4, the method reports almost 0% degradation across base and Sobolev loss and some other metrics while the other baselines degrade by 100s and 1000s of percentages. I am not sure if there is any metric saturation anywhere or some data leakage causing this. Can the authors explain this? Is there a way to compare the true loss values or to find the difference between predicted fields? Also there is no mention of if the experiments are averaged across multiple runs or if they are from a single run.
- Section 4.1 and Table 1 have some differences in the results reported. For e.g., the table report 19.72% but the paragraph reports 19.70% for the same configuration. Please fix this inconsistency.
- The paper uses L2 norm for the loss and objective functions in Section 3.1 but the paper discusses results only on L1 norm in the experiments. The paper should clarify why L1 outperforms L2 and could rederive derivations for L1.
Questions
- Can the authors report experiments for multiple runs and also provide some error bars for the results?
- Is it possible to show results for L2 norm as well to compare with the L1 norm results in the experiments?
Limitations
Yes
Final justification
The authors have responded to most of my queries and I feel I can raise my score to 4 from 3. The remaining issues as of right now are with the reported values and the calibration details presented on VICON and MPP.
Formatting concerns
No
7 comments
Rebuttal
We thank the reviewers for their helpful and constructive feedback. Our responses are provided below.
Weakness 1.1: if there is any metric saturation anywhere or some data leakage.
Weakness 1.2: Is there a way to compare the true loss values or to find the difference between predicted fields?
There is neither metric saturation nor data leakage. To verify the near-zero degradation, we report the raw loss values from Tables 2 and 4 to six decimal places (approximately ), an accuracy used to evaluate PDE surrogate models.
Table: Raw Loss on Poseidon.
| Ratio | Method | Size | NS-PwC Base Loss ↓ | NS-PwC Sobolev ↓ | NS-PwC Div-Free ↓ | NS-PwC Vorticity ↓ | CE-RM Base Loss ↓ | CE-RM Sobolev ↓ | Wave-Gauss Base Loss ↓ | Wave-Gauss Sobolev ↓ |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.0 | Origin | 628.6M | 0.002346 | 5.283677 | 0.022443 | 0.074452 | 0.675398 | 1806.582118 | 0.053786 | 5710.175821 |
| 0.8 | ASVD | 502.9M | 0.049272 | 52.020897 | 0.134364 | 1.180818 | 0.736271 | 1775.958009 | 0.097812 | 67969.314153 |
| 0.8 | FWSVD | 502.7M | 0.164924 | 125.534797 | 0.324314 | 2.797029 | 0.815371 | 2006.244402 | 0.354795 | 107290.637846 |
| 0.8 | SVD-LLM V2 | 524.2M | 0.163070 | 99.393721 | 0.269726 | 2.755940 | 0.829463 | 1779.526832 | 0.353159 | 77425.422663 |
| 0.8 | Dobi-SVD | 503.7M | 0.189102 | 119.586527 | 0.310397 | 2.895996 | 0.906149 | 1708.748682 | 0.394176 | 131465.388561 |
| 0.8 | SAES-SVD | 502.7M | 0.063724 | 92.646709 | 0.350908 | 1.317932 | 0.682649 | 1863.292494 | 0.177435 | 144908.644544 |
| 0.8 | Ours | 503.0M | 0.002346 | 5.283680 | 0.022443 | 0.074453 | 0.675398 | 1806.582191 | 0.053786 | 5710.177416 |
| 0.6 | ASVD | 376.9M | 0.107813 | 146.883963 | 0.475111 | 2.162998 | 0.846900 | 2014.990735 | 0.243183 | 359863.704893 |
| 0.6 | FWSVD | 377.1M | 0.169476 | 162.570272 | 0.403986 | 2.849220 | 0.832359 | 2420.457445 | 0.360187 | 143636.075134 |
| 0.6 | SVD-LLM V2 | 438.3M | 0.167446 | 134.674022 | 0.355126 | 2.792542 | 0.856292 | 2343.076295 | 0.363791 | 290164.448727 |
| 0.6 | Dobi-SVD | 378.1M | 0.177542 | 165.708592 | 0.502048 | 2.843103 | 0.916546 | 3038.127578 | 0.408015 | 531636.800308 |
| 0.6 | SAES-SVD | 377.1M | 0.069950 | 98.428941 | 0.375246 | 1.461335 | 0.690163 | 2017.772529 | 0.175208 | 197206.586203 |
| 0.6 | Ours | 377.5M | 0.002346 | 5.283981 | 0.022444 | 0.074461 | 0.675424 | 1806.623425 | 0.053787 | 5710.564509 |
| 0.4 | ASVD | 251.4M | 0.123614 | 235.851025 | 0.644856 | 2.539356 | 0.905710 | 2457.461326 | 0.309490 | 837808.684336 |
| 0.4 | FWSVD | 251.5M | 0.186414 | 273.718787 | 0.571973 | 3.023241 | 0.866756 | 3205.293762 | 0.370103 | 207990.694653 |
| 0.4 | SVD-LLM V2 | 374.9M | 0.207411 | 324.980443 | 1.039043 | 3.149890 | 0.917661 | 4020.915788 | 0.406619 | 1126462.928486 |
| 0.4 | Dobi-SVD | 252.6M | 0.201320 | 280.343788 | 0.630363 | 3.088124 | 0.940614 | 3039.797453 | 0.414363 | 605116.041955 |
| 0.4 | SAES-SVD | 251.5M | 0.074184 | 103.977274 | 0.388625 | 1.538947 | 0.698797 | 2140.966148 | 0.187863 | 235236.426873 |
| 0.4 | Ours | 251.9M | 0.002352 | 5.287955 | 0.022449 | 0.074575 | 0.675486 | 1807.712289 | 0.053809 | 5733.039429 |
| 0.2 | ASVD | 125.8M | 0.160122 | 331.959944 | 0.822106 | 3.177137 | 0.952436 | 5117.550250 | 0.336182 | 748449.058025 |
| 0.2 | FWSVD | 125.9M | 0.204614 | 409.462459 | 0.868615 | 3.258385 | 0.949415 | 5870.619010 | 0.406130 | 659618.391958 |
| 0.2 | SVD-LLM V2 | 353.2M | 0.225889 | 322.909589 | 0.961130 | 3.375724 | 1.090368 | 4435.062763 | 0.657377 | 1140022.617962 |
| 0.2 | Dobi-SVD | 127.0M | 0.208188 | 538.432974 | 1.144440 | 3.380004 | 0.977861 | 3164.483965 | 0.445664 | 1154844.295247 |
| 0.2 | SAES-SVD | 125.9M | 0.089766 | 133.638471 | 0.515947 | 1.880708 | 0.717621 | 2261.100429 | 0.251106 | 341074.854198 |
| 0.2 | Ours | 126.3M | 0.002408 | 5.378459 | 0.022559 | 0.075455 | 0.676077 | 1841.961242 | 0.054164 | 14385.645167 |
In all experiments, the training-calibration-testing split follows exactly the protocols in Poseidon, VICON, and MPP. Therefore, the calibration and evaluation sets are strictly separated, as described in Appendix C.1 and C.2. We will also release the code to support reproducibility.
Weakness 1.3: if the experiments are averaged across multiple runs or from single run.
Question 1: Report experiments for multiple runs and also provide some error bars for the results.
The experiments are based on a single run because the results are deterministic when the calibration dataset is fixed. Due to the space limit, please refer to our response to Reviewer XM4x, W1, for detailed report.
Weakness 2: Section 4.1 and Table 1 have some differences in the results reported.
Thanks for pointing out this inconsistency. We will modify it.
Weakness 3: The paper uses L2 norm for the loss and objective functions in Section 3.1 but the paper discusses results only on L1 norm in the experiments.
There is no inconsistency between theory and experiments. The experimental L1 norm refers to the L1 Sobolev loss, which is part of in Equation 4. The L2 norm in Equation 4 comes from Equation 2 and has never been an L1 norm.
Weakness 4.1: clarify why L1 outperforms L2.
Empirically, we find that the L1 Sobolev loss performs better because compression-induced derivative errors can be large at a few locations. Compared with L1 Sobolev Loss, the L2 Sobolev loss is more sensitive to these outliers, biasing the compression towards these outliers and giving overall worse accuracy.
Weakness 4.2: re-derivations for L1.
The choice between an and an Sobolev loss does not change the derivation of our final objective. Following BRECQ, the difference between the compressed-model loss and the original-model loss can be approximated using a second-order Taylor expansion:
where does not prescribe a specific form. In our setting, includes the Sobolev loss, which may use either an or an criterion. Following the BRECQ assumption that the pretrained model is sufficiently well trained, the expected first-order term is negligible, leading to
Under local linearization, and , yielding . Approximating using the Fisher information matrix then yields our Equation 1. This approximation interprets the objective as a composite log-likelihood, where the and terms correspond to Laplace and Gaussian distributions, respectively. We will clarify.
Question 2: Show results for L2 norm as well to compare with the L1 norm results in the experiments?
We provide the L2 norm Sobolev Loss results on Poseidon, VICON and MPP.
Table: Poseidon
| Ratio | Method | Size | NS-PwC: Base Loss ↓ | NS-PwC: Sobolev ↓ | NS-PwC: Div-Free ↓ | NS-PwC: Vorticity ↓ | CE-RM: Base Loss ↓ | CE-RM: Sobolev ↓ | Wave-Gauss: Base Loss ↓ | Wave-Gauss: Sobolev ↓ |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.0 | Origin | 628.6M | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% |
| 0.8 | Ours | 503.0M | 0.02% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 2.55% | 0.34% |
| 0.6 | Ours | 377.5M | 0.01% | 0.01% | 0.01% | 0.01% | 0.00% | 0.01% | 2.27% | 157.5% |
| 0.4 | Ours | 251.9M | 0.73% | 3.39% | 0.83% | 0.34% | 0.00% | 0.70% | 2.09% | 1923% |
| 0.2 | Ours | 126.3M | 58.04% | 224.2% | 119.0% | 30.76% | 1.04% | 18.54% | 33.04% | 10547% |
Table: VICON
| Ratio | Method | Size | NS-2D: Base Loss ↓ | NS-2D: Sobolev ↓ | NS-2D: Div-Free ↓ | NS-2D: Vorticity ↓ | Comp-2D: Base Loss ↓ | Comp-2D: Sobolev ↓ | Euler-2D: Base Loss ↓ | Euler-2D: Sobolev ↓ |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.0 | Origin | 87.8M | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% |
| 0.8 | Ours | 70.3M | 0.42% | 0.17% | 0.05% | 0.21% | 1.46% | 0.81% | 0.20% | 0.00% |
| 0.6 | Ours | 52.8M | 7.83% | 2.32% | 0.43% | 4.56% | 16.24% | 11.73% | 4.59% | 0.79% |
| 0.4 | Ours | 35.3M | 34.36% | 7.50% | 1.93% | 18.29% | 97.59% | 35.44% | 27.54% | 3.61% |
| 0.2 | Ours | 17.8M | 330.1% | 28.92% | 11.13% | 107.1% | 782.9% | 126.0% | 274.8% | 18.20% |
Table: MPP
| Ratio | Method | Size | IncompNS: Base Loss ↓ | IncompNS: Sobolev ↓ | IncompNS: Div-Free ↓ | IncompNS: Vorticity ↓ | CompNS: Base Loss ↓ | CompNS: Sobolev ↓ | DiffRe-2D: Base Loss ↓ | DiffRe-2D: Sobolev ↓ | SWE: Base Loss ↓ | SWE: Sobolev ↓ |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.0 | Origin | 407.1M | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% |
| 0.8 | Ours | 366.8M | 17.81% | 1.78% | 0.09% | 3.23% | 0.24% | 0.02% | 3.72% | 0.82% | 21.57% | 2.54% |
| 0.6 | Ours | 326.5M | 100.8% | 10.20% | 0.28% | 19.33% | 3.55% | 0.40% | 18.42% | 3.28% | 82.32% | 10.09% |
| 0.4 | Ours | 286.3M | 422.2% | 38.31% | 0.68% | 67.53% | 18.84% | 2.38% | 78.80% | 12.04% | 289.1% | 37.13% |
| 0.2 | Ours | 246.0M | 1851% | 124.3% | 1.90% | 183.6% | 152.3% | 14.01% | 354.9% | 45.89% | 1215% | 131.4% |
I thank the authors for the detailed rebuttal. It resolves a lot of my concerns. But I still have some concerns below based on the rebuttal results.
- Can the authors please state the calibration set size in the 5 subset study? The results depicted in the table here vs the paper seem to have a difference in a lot of configurations, in Poseidon for ratio 0.2, the main paper numbers fall outside the reported values (CE-RM base 0.1 vs 0.2, Div-Free 0.52 vs 2.17), while for ratio 0.4 they are on the other side (Base loss 0.26 vs 0.22, vorticity 0.17 vs 0.12). Since there are deviations towards both sides of the values, I think there is some difference in the calibration set size or it could be noise from different runs.
- Please label which configuration each rebuttal table reports. The VICON and MPP tables are labelled as "Ours", but the MPP variability figures match "Ours*" rather than Ours at every ratio.
- Based on L2 results here, the claim that L1 performs better seems to be true only for Poseidon. For VICON, when ratio is 0.8, L2 is better than L1 in Table 7. For MPP, it is a little unclear because L2 seems to beat "Ours" but not "Ours*".
- Can the authors please state the calibration set size in the 5 subset study? ... there are deviations towards both sides of the values, I think there is some difference in the calibration set size or it could be noise from different runs.
Thanks for pointing this out. The calibration dataset size is consistent with original experiments in the main paper. The trajectory number of 64 and final time 15(Wave-Gauss) or 20(NS-PwC and CE-RM for Poseidon. 2,048 samples for VICON, and 16 samples for MPP per physical scenario. After double checking the code we ran to get the results in the previous rebuttal, we found the code version was different from the one we used in the main paper. We apologize. Therefore, we have re-ran the experiments with more random seeds. Now we have a total of 11 results for each model including the original one in the main paper. We report them in the tables below. For better accuracy, we also kept 6 decimal places for Poseidon. For reproducibility, we will open-source the code upon acceptance.
All Poseidon results in the main paper fall into the ranges of the new results. There are a few exceptions in MPP and VICON results with small differences, such as MPP IncompNS Sobolev loss at ratio 0.2 and Div-Free at ratio 0.8; VICON NS-2D Base Loss and Vorticity at ratio 0.8. We will update the results in the final paper if accepted. We sincerely thank the reviewer for helping us to improve the experiments, which now conclusively show that SAFE-SVD reliably outperforms the baseline methods.
Table: Poseidon
| Ratio | Method | Size | NS-PwC Base Loss ↓ | NS-PwC Sobolev ↓ | NS-PwC Div-Free ↓ | NS-PwC Vorticity ↓ | CE-RM Base Loss ↓ | CE-RM Sobolev ↓ | Wave-Gauss Base Loss ↓ | Wave-Gauss Sobolev ↓ |
|---|---|---|---|---|---|---|---|---|---|---|
| 0.8 | Ours | 503.0M | 0.000325% ± 0.000022% | 0.000056% ± 0.000005% | 0.000079% ± 0.000006% | 0.000063% ± 0.000009% | 0.000009% ± 0.000000% | 0.000024% ± 0.000001% | 0.000130% ± 0.000009% | 0.000028% ± 0.000001% |
| 0.6 | Ours | 377.5M | 0.004377% ± 0.000993% | 0.010893% ± 0.003671% | 0.002497% ± 0.000175% | 0.011064% ± 0.000611% | 0.003824% ± 0.000264% | 0.002570% ± 0.000152% | 0.002638% ± 0.000182% | 0.006615% ± 0.000309% |
| 0.4 | Ours | 251.9M | 0.272097% ± 0.018793% | 0.082933% ± 0.009439% | 0.031330% ± 0.001561% | 0.167792% ± 0.008715% | 0.012852% ± 0.000888% | 0.046100% ± 0.002722% | 0.042955% ± 0.002967% | 0.389128% ± 0.018195% |
| 0.2 | Ours | 126.3M | 2.630446% ± 0.173058% | 1.817209% ± 0.179115% | 0.491240% ± 0.034353% | 1.324470% ± 0.091498% | 0.102373% ± 0.006863% | 0.992629% ± 0.079074% | 0.696032% ± 0.048073% | 147.252537% ± 7.164102% |
Table: VICON
| Ratio | Method | Size | NS-2D Base Loss ↓ | NS-2D Sobolev ↓ | NS-2D Div-Free ↓ | NS-2D Vorticity ↓ | Comp-2D Base Loss ↓ | Comp-2D Sobolev ↓ | Euler-2D Base Loss ↓ | Euler-2D Sobolev ↓ |
|---|---|---|---|---|---|---|---|---|---|---|
| 0.8 | Ours* | 70.3M | 2.32% ± 1.50% | 0.61% ± 0.44% | 0.17% ± 0.09% | 0.55% ± 0.37% | 2.20% ± 1.34% | 0.91% ± 0.48% | 3.15% ± 2.50% | 18.37% ± 12.94% |
| 0.6 | Ours* | 52.8M | 2.09% ± 1.58% | 0.38% ± 0.47% | 0.37% ± 0.14% | 1.21% ± 0.54% | 17.10% ± 3.59% | 7.74% ± 1.69% | 7.19% ± 3.63% | 15.51% ± 13.43% |
| 0.4 | Ours* | 35.3M | 20.64% ± 1.62% | 3.23% ± 0.53% | 1.01% ± 0.14% | 8.47% ± 0.62% | 73.42% ± 7.41% | 25.93% ± 2.38% | 28.07% ± 3.71% | 16.69% ± 12.52% |
| 0.2 | Ours* | 17.8M | 239.0% ± 6.25% | 20.41% ± 0.61% | 7.43% ± 0.31% | 66.07% ± 1.45% | 984.0% ± 79.79% | 104.2% ± 6.49% | 257.2% ± 10.65% | 14.34% ± 4.83% |
Table: MPP
| Ratio | Method | Size | IncompNS Base Loss ↓ | IncompNS Sobolev ↓ | IncompNS Div-Free ↓ | IncompNS Vorticity ↓ | CompNS Base Loss ↓ | CompNS Sobolev ↓ | DiffRe-2D Base Loss ↓ | DiffRe-2D Sobolev ↓ | SWE Base Loss ↓ | SWE Sobolev ↓ |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 0.8 | Ours* | 366.8M | 15.45% ± 1.91% | 1.54% ± 0.20% | 0.06% ± 0.02% | 2.81% ± 0.32% | 0.15% ± 0.14% | 0.08% ± 0.02% | 3.73% ± 0.69% | 0.89% ± 0.08% | 18.78% ± 2.08% | 2.38% ± 0.30% |
| 0.6 | Ours* | 326.5M | 90.86% ± 4.33% | 8.88% ± 0.61% | 0.22% ± 0.07% | 17.06% ± 0.99% | 1.89% ± 0.46% | 0.55% ± 0.11% | 15.70% ± 2.19% | 3.31% ± 0.21% | 71.20% ± 9.84% | 9.76% ± 0.98% |
| 0.4 | Ours* | 286.3M | 407.5% ± 10.54% | 36.07% ± 2.19% | 0.64% ± 0.14% | 66.54% ± 4.12% | 13.20% ± 1.89% | 2.84% ± 0.30% | 65.43% ± 6.50% | 11.59% ± 0.68% | 277.3% ± 24.42% | 36.00% ± 1.83% |
| 0.2 | Ours* | 246.0M | 1882% ± 104.6% | 129.9% ± 7.17% | 2.05% ± 0.22% | 197.5% ± 9.93% | 98.35% ± 10.17% | 12.74% ± 0.70% | 318.1% ± 25.30% | 43.50% ± 1.71% | 1246% ± 89.80% | 131.5% ± 5.79% |
- Rating
- 5/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper describes a compression techniques for neural networks specifically designed for physics applications. In particular, they introduce a layer compression based on sensitivity in the output space. They achieve higher compression ratios than the compared alternatives across various datasets, while maintaining accuracy.
Strengths and weaknesses
Quality The paper proposes a method based on singular value decomposition. The technique is derived analytically and then applied on experiments on several datasets. The study also includes ablations on the various components. The greedy global rank allocation is more empirical, but it is properly justified, and tested experimentally.
Clarity The paper reads well, the topic is appropriately introduced and motivated, images and tables describe the results. The main weakness that affects clarity is the use of physics terms such as "physical fidelity", "physics-aware SVD". In addition, "physical fidelity" may confuse the reader with a quantum physics background, where "fidelity" has a very specific meaning. A few minor concerns on clarity:
- Defining the Sobolev norm as it is being used in the main text would be helpful to the general reader.
- What is being compared in the tables is not immediately clear: what does the percentage represent (compression? error?). Specifically in Table 2 and 3: what is the number on the left (1, 0.6, 0,4, 0.2)? If it is the compression rate, it would be good to write, or add to the caption
- Summarizing in the conclusions the average compression rate that was obtained for a given loss threshold can help the reader understand the impact of the work.
- I believe the final sentence in the conclusions is too vague:
Also, there are other applications which do not require high precision, e.g. inverse design, and can benefit from model compression.
Significance Compressing scientific models can reduce inference costs and enable broader applications by the community, lowering access barrier.
Originality The work takes inspiration for existing SVD compression techniques, and proposes a decomposition that takes into account the global loss rather than the layerwise change. If this is the main contribution, and the proposed technique is fully general and not only applicable on physics settings, it would be good to clarify it in the text: this is a general compression technique and it can be applied also to foundation models, but nothing in the derivation is necessarily "physics aware" or requires physics knowledge about the system, right?
Questions
- What rank is used in the ablation with uniform rank allocation?
- How to choose the size of the calibration set? How to choose the tradeoff between accuracy and compute?
- Why the proposed SVD technique is physics-aware? (compared to the alternative baselines?
- Could one remove references to "physics aware loss" and focus the narrative on the fact that a global loss is being used for compression? Or is there some assumption that requires physics knowledge about the inputs? The physics setting could just be part of the work's motivation?
Limitations
yes
Final justification
I confirm my positive assessment.
Formatting concerns
no
4 comments
Rebuttal
We thank the reviewers for their helpful and constructive feedback. Our responses are provided below.
Calirty 1: the use of physics terms such as "physical fidelity", "physics-aware SVD". In addition, "physical fidelity" may confuse the reader with a quantum physics background.
We agree with the reviewer. ‘’Physical fidelity’’ in SAFE-SVD refers to the derivative structures. This is because SAFE-SVD is designed to work with different PDEs. Since physical fidelity has different meanings in different PDEs, e.g. divergence-free in NS-PwC and mass conservation in CE-RM, and the derivative structure is a common feature among PDEs, focusing on preserving this feature makes SAFE-SVD flexible. In this way, if the pretrained model can preserve fidelity and the fidelity can be described by partial derivatives, e.g. divergence-free, momentum conservation, SAFE-SVD also tends to preserve them. We will clarify.
Clarity 2: Defining the Sobolev norm as it is being used in the main text.
We will move the definition of the Sobolev norm from the supplementary material to the main text for clarity.
Clarity 3: What do the percentages represent, and what do the numbers on the left of Tables 2 and 3 mean?
The percentages report the relative increase of each metric over the uncompressed model:
where and are some metric of the compressed and original model, such as the L1 norm of the prediction error. is a small number to prevent divison by 0. Lower values are better. The leftmost values, {1, 0.6, 0.4, 0.2}, denote the target parameter retention ratio. Although all methods use retention ratio as a hyperparameter, some methods can’t precisely achieve the prescribed ratio, hence the differing sizes of the compressed models. Examples include Dobi-SVD and SVDLLM V2. We will clarify this definition in the captions of Tables 2 and 3.
Clarity 4: Summarizing in the conclusions the average compression rate that was obtained for a given loss threshold.
We will add a concise summary of the achieved compression rates in the conclusion. For example, for Poseidon, under a CE-RM base-loss threshold, our method retains only of the linear-layer parameters versus for the strongest baseline SAES-SVD; under a NS-PwC threshold, it retains whereas all baselines require the full model.
Clarity 5: Final sentence in the conclusions is too vague.
We will clarify this with a concrete example. Building ventilation design relies on aerodynamic simulations, where engineering decisions are often based on relative ventilation performance rather than exact flow predictions(Chen and Gorlé, 2022). Consequently, moderate approximation errors can often be tolerated, allowing compressed physics foundation models to serve as efficient surrogate models that substantially reduce computational cost.
Originality and Question 4: Can we remove references to "physics aware loss" and narrow it down to global loss.
SAFE-SVD does require physics knowledge about the inputs. The method is specifically designed for PFMs, whose inputs are functions, which is a key distinction from other foundation models. Accordingly, the entire design revolves around preserving compression-sensitive derivative structures, and the orders of these derivatives depend on the specific PDE family under consideration. Therefore, trimming SAFE-SVD down to only using a generic global loss would discard the central physics awareness of the method.
That said, we agree that, if only the base loss is used, components such as loss-aware sensitivity estimation and global rank allocation could potentially be adapted to other foundation models. We thank the reviewer for pointing out this possibility and will include it as an important direction for future work.
Question 1: What rank is used in the ablation with uniform rank allocation?
In the uniform rank allocation ablation, the rank of each linear layer is computed as
where and are the output and input dimensions of the layer, respectively, and is the target parameter retention ratio. This yields approximately uniform parameter retention across layers.
Question 2: How to choose the size of the calibration set? How to choose the tradeoff between accuracy and compute?
We provide new results on the trade-off between compression efficiency and performance on Poseidon. In practice, people can balance them based on their needs.
Table: Accuracy–compute trade-off on Poseidon NS-PwC at retain ratio 0.2.
| Method | Calib. traj. | Rank selection (min) | Compression (min) | Total (min) | GPU alloc. peak (GB) | Base Loss | Div-Free | Vorticity |
|---|---|---|---|---|---|---|---|---|
| SAFE-SVD | 4 | 2.82 | 34.40 | 37.22 | 15.46 | 3.93% | 0.68% | 2.93% |
| SAFE-SVD | 8 | 4.62 | 69.94 | 74.55 | 15.46 | 3.55% | 0.83% | 2.36% |
| SAFE-SVD | 16 | 7.59 | 131.06 | 138.65 | 16.83 | 4.32% | 1.75% | 2.21% |
| SAFE-SVD | 32 | 12.37 | 310.78 | 323.15 | 27.81 | 5.58% | 2.98% | 2.50% |
| SAFE-SVD | 64 | 20.36 | 427.75 | 448.11 | 50.57 | 2.64% | 0.52% | 1.35% |
Question 3: Why the proposed SVD technique is physics-aware? (compared to the alternative baselines?
SAFE-SVD is physics-aware because it explicitly links intermediate-layer compression to the derivative structure of output function via a Sobolev loss. In contrast, ASVD, SVD-LLM V2, and SAES-SVD optimize only local reconstruction, without considering the global loss which includes the derivative structure. Although FWSVD considers the global loss, it doesn’t include derivative structures. Furthermore, unlike SAFE-SVD, FWSVD doesn’t capture the full Fisher information, only its diagnol elements, while the off-diagnol elements contain rich physics information.
Dear Reviewers,
Thank you for your time and effort throughout the review process.
This is a kind reminder that the author–reviewer discussion phase will conclude on August 3. We encourage you to engage with the authors’ rebuttals at your earliest convenience.
Best,
ACs
I thank the authors for the answers to my questions. I confirm the positive assessment.
In my opinion, expanding on physics awareness through Sobolev loss (i.e. the fact that this loss depends on the reference field) in the main text will emphasize the proposed method's novelty for the reader.
We sincerely appreciate the reviewer for confirming the positive assessment. We will emphasize that point in the main text.
Comments on the paper
1 comment
Author–Reviewer Discussion
Dear Reviewers,
This is a kind reminder that the author–reviewer discussion period will close soon. If you have not yet done so, please take a moment to review the authors’ responses and continue the discussion as needed, particularly to indicate whether your concerns have been adequately addressed.
Thank you for your time and engagement.
ACs
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Thanks for the helpful and constructive feedback. Our responses are provided below.
Issue 1.1: Please provide raw, unrounded losses in addition to relative percentages.
We have provided the loss values in our response to Reviewer SeTW (see Weakness 1.1 and Weakness 1.2)
Issue 1.2: Clearly confirm calibration/test separation
We have clearly described the separation between the calibration and test sets in our response to Reviewer SeTW (see Weakness 1.1 and Weakness 1.2).
Issue 1.3: Explain the baseline adaptations.
Baseline adaptations are detailed in Appendix F. For methods without released official implementations, including SVD-LLM V2 and SAES-SVD, we implemented them following their papers.
Issue 1.4: the differing final model sizes. and Issue 4.2: Why model sizes differ.
The final model sizes differ because each method adopts a different rank-selection strategy. Although all these methods use a hyperparameter specifying the target compression ratio, some methods cannot precisely achieve the prescribed ratio, hence the differing sizes of the compressed models. Examples include Dobi-SVD and SVDLLM V2.
Issue 1.5: State whether the results are deterministic or sensitive to calibration-subset selection.
The results are deterministic given fixed calibration dataset and are not senstive to calibration subset selection. Details are in the response to Reviewer XM4x W1.
Issue 2: Clarify which claims are supported across the other PDE families and narrow “physical fidelity” to derivative fidelity where conservation or constraint metrics are unavailable.
In our response to Reviewer pbxu, Clarity 1, we have narrowed the scope of ‘’physical fidelity’’ to the preservation of derivative structures. We do not claim a universal guarantee across all PDE families or conservation or constraint metrics. Nevertheless, the additional results in our response to Reviewer XM4x, W2, provide empirical evidence that derivative-structure preservation can maintain conservation or constraint metrics when they can be described by derivatives, such as the divergence-free behavior in incompressible Navier-Stokes(NS-PwC) and mass conservation in compressible Euler(CE-RM).
Issue 3.1: Distinguishing the quadratic activation-space surrogate from the L1 Sobolev Loss.
We have explained the difference in the responce to Reviewer SeTW Weakness 3.
Issue 3.2: State the assumptions underlying the Fisher/Gauss–Newton approximation and omission of the first-order Taylor term.
In response to Reviewer SeTW's Weakness 4.2 for a derivation applicable to the L1 Sobolev loss, we provide the corresponding assumptions.
Issue 4.1: Define precisely what ratios such as 0.2, 0.4, and 0.6 retain.
The retain ratio is a hyperparameter shared by all methods that specifies the target proportion of model parameters to be retained after compression. We provide its definition in our response to Reviewer pbxu, Clarity 3.
Issue 4.3: Distinguish parameter reduction from demonstrated memory or latency improvements.
We report new experiments below, averaged across 10 inference runs on Poseidon with retain ratio 0.2. Parameter reduction directly decreases model storage requirements and reduces FLOPs. We clarify that these experiments are conducted on a single RTX 3090, including CPU-GPU transfer, data storage.The overall performance (latency, VRAM, and FLOPs) might vary on different hardware.
Table: Inference effiency comparison on Poseidon.