NeuroNTP - A Generalizable Multimodal Foundation Model for Epilepsy
József Kovács, Amadeus Hauser, Gudrun Gröppel, Wolfgang Narzt, Philipp Seidl
TL;DR. NeuroNTP is a multimodal foundation model pretrained on 150k hours of clinical data (EEG, ECG, SpO2, and clinical text) that achieves SOTA seizure detection on public benchmarks (CHB-MIT, Siena Scalp EEG) via long-range cross-modal modeling
Abstract. Epilepsy affects approximately % of the global population, where seizure detection and reliable forecasting are critical for patient safety and quality of life. While emerging foundation models increasingly recast EEG analysis as a language modeling task, most remain confined to single-modality inputs and narrow domain generalization. In this work, we present NeuroNTP, a modular multimodal foundation model built on an xLSTM backbone and pretrained on one of the largest retrospective epilepsy datasets ever collected, comprising hours of neural (EEG) and physiological (ECG, SpO$_2$) signals paired with rich clinical text. NeuroNTP uses a flexible tokenizer based on montage geometry. It combines causal next-token prediction, which allows streaming inference, with seizure-proximity supervision: auxiliary regression targets that encode the temporal distance to the preceding and the upcoming seizure. This enables unified sequence modeling across modalities. This approach allows the model to capture long-range temporal dependencies and cross-modal interactions that unimodal baselines ignore. In extensive experiments, we show that NeuroNTP outperforms supervised baselines by a substantial margin on held-out clinical cohorts. Furthermore, the model generalizes to public EEG benchmarks such as CHB-MIT and Siena Scalp EEG, achieving state-of-the-art balanced accuracy and AUROC under standard evaluation settings. We release code and model weights to facilitate further research: https://github.com/ml-jku/neurontp.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:49 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
Summary:
This paper introduces NeuroNTP, an xLSTM-based multimodal foundation model that unifies EEG, ECG, SpO₂, clinical text, temporal context, and metadata through geometry-aware tokenization and causal next-token pretraining with seizure-specific auxiliary objectives. The model is pretrained on more than 150,000 hours of private clinical recordings and evaluated on seizure detection, prediction, and clinical-marker inference using the KUK cohort and the public CHB-MIT and Siena Scalp EEG benchmarks. Although the results demonstrate strong cross-dataset performance and promising efficiency for continuous monitoring, the reviewers raised substantial concerns regarding technical novelty, deployment-faithful evaluation, attribution of performance gains, and reproducibility.
Strengths:
Reviewers idBm, YwCK, and s5Th consistently recognize the importance of the clinical problem, the exceptional scale and multimodal richness of the pretraining dataset, and the practical value of integrating heterogeneous physiological signals and clinical context within a unified framework. They also acknowledge the strong empirical performance across multiple epilepsy-related tasks and datasets, the efficient stateful architecture, the broad baseline coverage, and the planned release of code and pretrained weights.
Weaknesses:
Reviewers idBm and s5Th question whether the methodological contribution is sufficiently novel, noting that next-token prediction, multimodal token concatenation, xLSTM, and spatial electrode encodings largely build upon existing techniques and that comparisons with relevant multimodal or sub-quadratic foundation models remain incomplete. Reviewers idBm and s5Th also find the source of the reported gains insufficiently disentangled, requesting controlled scaling, backbone, objective, modality, and pretraining-data ablations to separate the effects of dataset scale and quality from those of the proposed design. Reviewer YwCK raises a central deployment concern that clinical markers, post-hoc notes, seizure delimiters, or ground-truth time-past-seizure information may provide unavailable or potentially leakage-prone signals at inference, while the parameterization of the multi-quantile next-token objective is also unclear. Reviewers YwCK and s5Th further note that the broad SOTA and zero-shot montage-generalization claims require more precise qualification and validation, while reliance on a non-public private dataset, potentially identifying institutional information, and incomplete descriptions of some auxiliary-task results limit reproducibility and confidence in the conclusions.
Response Direction:
The acceptance likelihood could increase substantially if the response provides a strict biosignal-only, causally valid evaluation without seizure-derived annotations or ground-truth TPS, controlled experiments disentangling data scale, architecture, modalities, and objectives, clearer validation and novelty positioning for montage generalization, and precise corrections or clarifications regarding the quantile loss, SOTA claims, baseline comparability, and reproducibility.
Final Assessment:
The authors provided substantive clarifications in response to several of the technical concerns raised during review, including the biosignal-only evaluation setting, the scope of the SOTA claims, and the role of seizure-derived annotations. Nevertheless, some important concerns remain only partially resolved, with several proposed remedies deferred to revisions rather than supported by new, independently verifiable evidence. I recommend weak accept.
Final justification
Please see the updated meta-review above for the final justification.
Note from PC: The appeal of hallucinated reference determination has been reviewed. The decision now reflects the outcome of the appeals process as well as the content of the reviews, scores, and meta-review.
Read meta-review
Meta-review
Summary:
This paper introduces NeuroNTP, an xLSTM-based multimodal foundation model that unifies EEG, ECG, SpO₂, clinical text, temporal context, and metadata through geometry-aware tokenization and causal next-token pretraining with seizure-specific auxiliary objectives. The model is pretrained on more than 150,000 hours of private clinical recordings and evaluated on seizure detection, prediction, and clinical-marker inference using the KUK cohort and the public CHB-MIT and Siena Scalp EEG benchmarks. Although the results demonstrate strong cross-dataset performance and promising efficiency for continuous monitoring, the reviewers raised substantial concerns regarding technical novelty, deployment-faithful evaluation, attribution of performance gains, and reproducibility.
Strengths:
Reviewers idBm, YwCK, and s5Th consistently recognize the importance of the clinical problem, the exceptional scale and multimodal richness of the pretraining dataset, and the practical value of integrating heterogeneous physiological signals and clinical context within a unified framework. They also acknowledge the strong empirical performance across multiple epilepsy-related tasks and datasets, the efficient stateful architecture, the broad baseline coverage, and the planned release of code and pretrained weights.
Weaknesses:
Reviewers idBm and s5Th question whether the methodological contribution is sufficiently novel, noting that next-token prediction, multimodal token concatenation, xLSTM, and spatial electrode encodings largely build upon existing techniques and that comparisons with relevant multimodal or sub-quadratic foundation models remain incomplete. Reviewers idBm and s5Th also find the source of the reported gains insufficiently disentangled, requesting controlled scaling, backbone, objective, modality, and pretraining-data ablations to separate the effects of dataset scale and quality from those of the proposed design. Reviewer YwCK raises a central deployment concern that clinical markers, post-hoc notes, seizure delimiters, or ground-truth time-past-seizure information may provide unavailable or potentially leakage-prone signals at inference, while the parameterization of the multi-quantile next-token objective is also unclear. Reviewers YwCK and s5Th further note that the broad SOTA and zero-shot montage-generalization claims require more precise qualification and validation, while reliance on a non-public private dataset, potentially identifying institutional information, and incomplete descriptions of some auxiliary-task results limit reproducibility and confidence in the conclusions.
Response Direction:
The acceptance likelihood could increase substantially if the response provides a strict biosignal-only, causally valid evaluation without seizure-derived annotations or ground-truth TPS, controlled experiments disentangling data scale, architecture, modalities, and objectives, clearer validation and novelty positioning for montage generalization, and precise corrections or clarifications regarding the quantile loss, SOTA claims, baseline comparability, and reproducibility.
Final Assessment:
The authors provided substantive clarifications in response to several of the technical concerns raised during review, including the biosignal-only evaluation setting, the scope of the SOTA claims, and the role of seizure-derived annotations. Nevertheless, some important concerns remain only partially resolved, with several proposed remedies deferred to revisions rather than supported by new, independently verifiable evidence. I recommend weak accept.
Final justification
Please see the updated meta-review above for the final justification.
Note from PC: The appeal of hallucinated reference determination has been reviewed. The decision now reflects the outcome of the appeals process as well as the content of the reviews, scores, and meta-review.
1 comment
- Rating
- 5/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 2/4
- Significance
- 4/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper introduces NeuroNTP, a training framework and architecture designed to support a broad range of epilepsy-related predictive tasks (seizure prediction/classification/clinical marker inference/time-to seizure detection, some other auxiliary tasks). The key contribution of the work is a novel multimodal pretraining strategy that jointly leverages heterogeneous clinical data sources, including EEG recordings, clinical notes, SpO2 measurements, and EKG signals.
The proposed architecture combines modality-specific encoders tailored to each data type: a DFT-based convolutional encoder for EEG signals, a medical BERT model for clinical text, and learned embedding lookup tables for structured physiological variables. These modality-specific representations are integrated through an xLSTM backbone, which captures temporal dependencies across modalities, while lightweight task-specific linear or multilayer perceptron (MLP) heads enable adaptation to individual downstream tasks.
The authors evaluate NeuroNTP on both a large private dataset (KUK) and two publicly available epilepsy datasets, CHB-MIT and Siena Scalp EEG. Across these benchmarks, NeuroNTP is compared against a comprehensive set of contemporary seizure forecasting and detection methods. The results demonstrate state-of-the-art performance on the private KUK dataset for both seizure prediction and seizure detection tasks. On the public datasets, NeuroNTP achieves the second-best seizure detection performance, closely trailing the performance of CSBrain. Overall, the work presents a competitive multimodal framework for seizure forecasting and detection, highlighting the potential benefits of multimodal pretraining for epilepsy related downstream applications.
Strengths and weaknesses
Strengths:
- This work is (to my knowledge) the first work that combines a variety of different data such as eeg + text + SpO2 + ekg in a unified training scheme for seizure detecton. The authors demonstrate that this approach is very competitive and in some cases achieves SOTA performance compared to other approaches that use rely on eeg data only.
- The authors compared their approach against a comprehensive suite of publicaly available models and publicaly available datasets. This enhances the credibility of their results and encourages reproducibility of findings.
- The authors also evaluate their model on a variety of epilepsy related task, demonstrating that their approach is robust to multiple different tasks, minimizing the risk of their results being an overfiting artifact.
- The authors introduce a novel pretraining schema that could be used as inspiration by other researchers in the field.
- The authors will make their architecture and weights available as a resource to the community.
Weaknesses:
- The authors on multiple occasions provide somewhat identifying information, jeopardizing the double blind peer review (i.e. mention the name of their private KUK dataset which points to specific insitutions, also directly reference their ethics vote on line 342).
- The authors do not intent to make their private KUK dataset public. This is unfortunate, not only because this dataset is orders of magnitude larger than other publicaly available datasets and therefore could be a huge asset for the community, but also because the authors report that their model is SOTA on this dataset only.
Questions
- In lines 317-318, the authors mention: "we demonstrate that scaling data and model capacity unlocks superior performance on downstream tasks,even when transferring to modality-constrained settings.". However, the is no evidence supporting this claim in the main text. To investigate whether this claim is true, please perform the following experiments:
- Pretrain your model on 0, 25, 50, 75 % of your available data. Compare the performance of the model on downstream tasks for the different levels of pretraining data fed to the model.
- Using a fixed size dataset (say 100% of your available data) train your proposed network with 25, 50, 75, 100% of your current trainable parameters. Compare model performance on downstream tasks for the different levels of model parameters.
- In line 322 you mention "neuroNTP generalizes zero-shot across spatial montages". However, in lines 152-153 you mention: "To specialize the shared features for individual channels, we apply a small channel-specific adaptation head based on a bottleneck projection and a low-rank residual update." Please explain how do you pick the values for the channel-specific adaptation heads to enable zero-shot generalization.
- In line 42 you mention "Incorporating 3D spatial electrode coordinates and channel dropout enables zero-shot adaptation to arbitrary montages" as one of your main contributions. I am aware of at least 3 other works that employ a very similar scheme, (1) seegnificant (https://arxiv.org/abs/2411.10458) , (2) PopT (https://arxiv.org/abs/2406.03044), (3) BaRISTA (https://arxiv.org/abs/2512.12135). Please explain what is the contribution of your work in terms of spatial encoding compared to these works.
Limitations
- Authors do not intent to make their private dataset public. Limits reproducibility of findings.
- The authors mention in multiple instances that transformers suffer from quadratic complexity. This, however, is false since Flash attention can reduce memory overhead to linear complexity (https://arxiv.org/abs/2205.14135) and KV-caching enables near linear computational complexity for transformers (https://arxiv.org/abs/2606.02964). I highly suggest that those claims be removed from the manuscript.
- Section 5.3.2 (lines 280-295) should be rewritten to describe the main results of the experiments described there. Currently, the do not confer any meaningful information about how any model (including that of the authors) performs on those tasks.
Final justification
The authors clarified most of my remaining concerns. I feel that their contributions are worth publishing.
Formatting concerns
N/A
3 comments
Rebuttal
We thank the reviewer for the constructive assessment and for recognizing the multimodal contribution and task breadth. We address the anonymity issue, the two requested experiments, and each question below.
We apologize for leaving the institutional reference and ethics-vote number in the review copy. We note this does not uniquely identify the author group — the cohort spans an 11-year acquisition period across a broad internal and external research network — so we do not believe it compromised the double-blind assessment.
Dataset non-release
We share the reviewer's regret. Release is precluded by patient-privacy law governing the clinical cohort, not by choice. To mitigate, we release the full architecture and pretrained weights, and we validate the framework end-to-end on the fully public TUSZ corpus (Appendix H), so that the method — if not the private data — is independently reproducible.
Q1a — Data scaling
We agree the scaling claim (lines 317–318) needs direct evidence and was overstated relative to what the main text shows; we will soften the wording and add the experiment. A controlled data-fraction study (25/50/75/100%) is in progress. As an interim, verifiable proxy we report biosignal-only linear-probing performance across pretraining epochs, where an epoch is defined as a weighted subsample covering 3% of the dataset.
| Epoch | Val. Loss | AUPRC | AUROC |
|---|---|---|---|
| 10 | 0.1156 | 24.03 | 61.58 |
| 20 | 0.0661 | 22.93 | 63.55 |
| 30 | 0.05123 | 32.98 | 73.86 |
| 40 | 0.04176 | 37.97 | 76.39 |
| 50 | 0.03851 | 39.32 | 77.73 |
| 60 | 0.03750 | 40.57 | 76.54 |
| 70 | 0.03660 | 45.89 | 79.43 |
| 80 | 0.03689 | 42.73 | 77.32 |
| 90 | 0.03659 | 45.45 | 78.67 |
| 100 | 0.03655 | 45.98 | 78.49 |
We are explicit that this is a proxy: it does not disentangle data volume from continued optimization, since parameters keep updating. It shows the trend but is not a substitute for the controlled study, which we commit to include.
Q1b — Parameter scaling
We compare backbone sizes at matched pretraining budget:
| Backbone | BACC | AUPRC | AUROC |
|---|---|---|---|
| 11M | 53.1 | 44.2 | 74.3 |
| 18.6M | 50.5 | 46.7 | 82.5 |
| 37M | 65.1 | 48.4 | 84.6 |
Performance improves with capacity across this range. (We also trained a 72M variant; at the fixed epoch budget it was undertrained and not yet comparable — larger models require a longer schedule — so we exclude it pending a compute-matched run rather than report a misleading point.)
Q2 — Channel-specific adaptation vs. zero-shot
The reviewer correctly identifies an apparent tension. The two operate in different regimes, which we will state clearly:
- Zero-shot (frozen): In the frozen setting (Table 3), no channel-specific parameters are trained for the new montage. Each new electrode's adapter is populated by copying the weights of the spatially nearest pretrained electrode, selected by Euclidean distance in 3D coordinate space; these weights are then used without any gradient update. Adaptation is therefore a parameter-selection operation, not a learning one — the network is unchanged from pretraining. Appendix J.2's nearest-neighbour scheme serves as frozen reuse here, and as initialization in the separate finetuned regime.
- Finetuned: when finetuning is permitted, the channel-specific adaptation head (lines 152–153) is initialized from the nearest spatial neighbour in coordinate space (Appendix J.2) and then optimized — an initialization strategy, not a requirement for the zero-shot case. We will move this distinction into the main body and correct the wording so "zero-shot" is unambiguous.
Q3 — Spatial encoding vs. seegnificant / PopT / BaRISTA
We thank the reviewer for these references and will cite and discuss them. We agree spatial priors are an established direction and will not claim the idea is novel per se. While seegnificant, PopT, and BaRISTA utilize absolute 3D coordinates, they map them into learned spatial embeddings or rely on cross-electrode self-attention. Our distinction is mechanistic: rather than learned positional embeddings over a fixed electrode set, we use a continuous 3D-coordinate projection that is (i) independent of any fixed montage vocabulary and (ii) usable to initialize adaptation to unseen electrodes by Euclidean proximity, enabling the frozen-backbone transfer above. We will state this comparison explicitly rather than as a bare contribution claim.
Limitation — Transformer complexity
We acknowledge the imprecision in our claims and will correct the manuscript. FlashAttention reduces attention memory to linear but leaves compute quadratic in sequence length; KV-caching gives linear-time per-step decoding but with memory growing linearly in context. Our claim is specifically about streaming inference over very long continuous recordings, where these still scale unfavourably — Appendix I.4 measures Transformer memory exhausting beyond ~20–25k tokens while xLSTM holds constant latency and memory. We will restate the complexity claims in these precise terms and reference I.4, rather than as a blanket assertion.
§5.2.3 (lines 280–295)
We agree this section currently lists tasks without reporting outcomes. We will rewrite it to report results for the auxiliary/marker-inference tasks (drawing on Table 2 and Appendix G) and state what they show about representation quality, rather than only describing the setup.
Additional (wearable proxy)
Relevant to the modality-constrained claim the reviewer probed, we will extend the Appendix J modality ablation with a behind-the-ear (BTE) configuration approximating a wearable setting (BTE-only: 82.8% AUROC; BTE+ECG+SpO₂: 83.9%), showing the framework degrades gracefully under sensor-restricted deployment.
I would like to thank the authors for taking the time to respond to my questions and for providing detailed clarifications. I really appreciate the effort that went into addressing my concerns.
We note this does not uniquely identify the author group — the cohort spans an 11-year acquisition period across a broad internal and externaal research network — so we do not believe it compromised the double-blind assessment.
Thank you for the clarification. While I agree that this does not uniquely identify the author group, I do think it substantially narrows down the set of possible groups that could have produced this work. For researchers who are closely familiar with this area, I believe this information could meaningfully compromise the double-blind review process. I would encourage the authors to be a bit more cautious with similar details in future submissions.
Q1a — Data scaling
If you are able to obtain these results before the rebuttal deadline, I would be very interested to see them. Please do let me know if they become available.
Q1b — Parameter scaling
Thank you for providing this additional analysis. I think these results strengthen the paper's scalability claims and would make a valuable addition to the manuscript. I encourage you to include them in the final version.
Q2 — Channel-specific adaptation vs. zero-shot
Thank you for the clarification. I think it would be very helpful to make this distinction explicit in the manuscript. In particular, please clearly indicate whenever parameters are fine-tuned so that readers can accurately interpret the reported results and avoid confusing fine-tuned and zero-shot settings.
Q3 — Spatial encoding vs. seegnificant / PopT / BaRISTA
rather than learned positional embeddings over a fixed electrode set, we use a continuous 3D-coordinate projection that is (i) independent of any fixed montage vocabulary and (ii) usable to initialize adaptation to unseen electrodes
I believe this particular claim may not be entirely accurate. My understanding is that BaRISTA also supports adaptation to previously unseen electrodes, and I believe similar capabilities exist in Seegnificant and PopT as well. More generally, none of these methods rely on a truly "fixed electrode set", as such an assumption would not be practical given the distributed and highly variable nature of invasive EEG recordings. I would encourage the authors to either refine this comparison or more clearly explain the specific distinction they are trying to make.
Limitation — Transformer complexity
Our claim is specifically about streaming inference over very long continuous recordings, where these still scale unfavourably — Appendix I.4 measures Transformer memory exhausting beyond ~20–25k tokens while xLSTM holds constant latency and memory
Thank you for clarifying the scope of this claim. Please make sure the manuscript is updated to reflect this more precise wording so that the claims are presented accurately. If time allows, please explain which claims (can reference by line in text) you plan to revise and how.
§5.2.3 (lines 280–295)
** We will rewrite it to report results for the auxiliary/marker-inference tasks (drawing on Table 2 and Appendix G) and state what they show about representation quality.
Thank you for the clarification. If time permits, I would appreciate a bit more detail on how you plan to revise this section. In particular, it would be helpful to explicitly connect each experiment to its corresponding result and explain how those results can be interpreted. While I appreciate your commitment to improving the presentation, having this additional context would provide useful information as I consider whether to update my score.
Overall, I appreciate the thoughtful and detailed rebuttal. The authors addressed many of my questions, and I found the additional analyses and clarifications helpful. I believe that incorporating the promised revisions into the manuscript will make the paper significantly stronger and easier for readers to follow. I wish the authors the best of luck with the paper and look forward to seeing the final version.
We thank the reviewer for the continued engagement and for the constructive tone throughout. We address each point below.
Q1a Data scaling. To evaluate pretraining data scaling, we kept the architecture, training pipeline, epochs, and hyperparameters fixed, varying only the pretraining data (25%, 50%, 75%, 100%). Subsets were patient-level, nested, and stratified by recording duration. Representations were evaluated by identical linear probing on a held-out patient set. Preliminary results:
| Data Scale | NTP Loss | AUPRC | AUROC |
|---|---|---|---|
| 100% | 0.0356 | 41.65 | 79.34 |
| 75% | 0.0735 | 41.09 | 78.28 |
| 50% | 0.0796 | 38.63 | 77.17 |
| 25% | 0.1368 | 31.70 | 71.83 |
Q1b Parameter scaling. Thank you; we will include the parameter-scaling analysis in the final version.
Q2 Channel-specific adaptation vs. zero-shot. We will explicitly distinguish adapted and zero-shot tokenizer parameters in the text and table captions, preventing any conflation of the two settings. This will be folded into the same input-visibility labeling we are adding for the deployment settings.
Q3 Spatial encoding vs. Seegnificant / PopT / BaRISTA. We accept this correction and will revise the comparison. Prior work already supports unseen-electrode adaptation; our intended distinction is mechanistic rather than capability-based. NeuroNTP represents electrodes by continuous 3D-coordinate projections and initializes new electrodes from the nearest spatial neighbor (Appendix J.2), rather than relying solely on learned per-label embeddings. We will revise lines ~662–667 accordingly, cite BaRISTA, PopT, and Seegnificant, and state that geometry-based unseen-electrode adaptation is a shared direction rather than a unique contribution.
Limitation / Transformer complexity. We will scope these claims precisely to streaming inference over long continuous recordings and update the wording accordingly. Concretely: (i) the contribution bullet (line ~40) and the positioning text (lines ~671–673) will be qualified so that the linear-complexity/stateful-inference advantage is stated for the streaming long-context regime rather than in general; (ii) the "standard Transformers struggle … due to quadratic scaling" claim (lines ~660–661) will be reworded to refer specifically to memory/latency growth under streaming over long histories; and (iii) each of these will point to Appendix I.4 (Figure 12), where Transformer variants exhaust memory beyond ~20–25k tokens while xLSTM holds constant latency and memory.
§5.2.3 (lines 280–295): auxiliary-task rewrite. We will rewrite this section to report and interpret results per task, rather than describe the tasks alone. The planned structure:
Clinical Marker Inference → results from Table 2 (group-level marker detection) with the confusion matrix in Appendix G. Interpretation: the model reconstructs clinically meaningful annotation semantics from biosignals, strongest for EEG-phenomenon markers (F1 81.6%), which have direct electrographic correlates, and weaker for behavioural/other markers (F1 46.7% / 23.9%), which depend on context not present in the biosignal stream; evidence that the learned representations align physiological patterns with clinical vocabulary where such a correlate exists.
Time-to-Seizure (TTS) regression → the linear-probing evaluation showing that pre-seizure latent trajectories carry linearly separable proximity information, complemented by the ablation in Table 13, where removing TTS is the single largest degradation - establishing TTS as the dominant driver of representation quality.
Structural tasks (TPS, token-type, segment-type) → the corresponding Table 13 ablation rows for each objective's marginal contribution, and the frozen segment-type linear-probing results with biosignal-only input (Table 3) as a direct read of ictal/non-ictal separability across KUK, CHB-MIT, and Siena, extended by using two pretraining configurations (biosignal-only and multimodal).
The section will close by tying these together: the auxiliary evaluations jointly show the representations encode clinical-annotation semantics, temporal proximity to seizures, and ictal/non-ictal structure, which is the concrete evidence behind our claim that proximity-shaped multitask supervision yields semantically and temporally rich representations.
We are grateful for the specificity of these suggestions, which have made the intended revisions much clearer.
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
NeuroNTP is a multimodal foundation model for epilepsy analysis. It represents EEG, ECG, SpO₂, clinical markers/notes, temporal context, and metadata as a unified causal token sequence, processes the sequence with an xLSTM backbone, and trains with causal next-token prediction plus seizure-relevant auxiliary objectives. The model is pretrained on the large private KUK dataset, comprising more than 150k hours of multimodal clinical monitoring data, and is evaluated on held-out KUK patients, CHB-MIT, Siena Scalp EEG, seizure prediction horizons, and clinical marker inference. The main contributions are large-scale epilepsy-specific multimodal pretraining, montage-geometry-aware tokenization, stateful long-context modeling, and strong transfer results for seizure detection and prediction.
Strengths and weaknesses
Strengths
- The paper tackles an important and clinically meaningful problem: building seizure analysis models that generalize across patients, recording setups, montages, and long-duration monitoring streams. The proposed framework is well motivated.
- The tokenization scheme supports heterogeneous biosignals and clinical context, and the use of 3D electrode-location information is a reasonable way to improve montage transfer.
- The KUK dataset is a major asset: the manuscript reports more than 153k hours from 1,302 patients, with EEG, ECG, SpO₂, and temporally aligned clinical annotations. Moreover, the reported results are encouraging, especially the strong KUK performance and competitive transfer to CHB-MIT and Siena.
Weaknesses
- The main unresolved weakness is that the strongest multimodal gains may depend on clinical markers, notes, or seizure-derived temporal variables that would not be available in a strict deployable setting. The paper states that clinical markers and notes are used as input, and the KUK marker vocabulary includes seizure-related annotations such as seizure delimiters. This does not prove leakage: the authors state that TTS is withheld from input and that inference is causal. However, the paper does not specify exactly which markers and notes are available at inference time, nor whether seizure delimiters or post-hoc annotations are excluded from the input context used for ictal/non-ictal prediction. This issue is central because the paper reports a large performance jump when clinical text is included. Unclear TPS protocol.
- A related concern is TPS. The paper states that TPS is provided as input and computed globally per patient from real-world timestamps, but it does not clearly explain how TPS is initialized and updated during validation/test streaming. In a prospective deployment, TPS would need to come from known prior clinical records or from the model’s own online predictions, not from ground-truth seizure annotations unavailable at inference time. The claims would be much stronger with a strict deployment-faithful evaluation: biosignals only, no clinical seizure markers, no post-hoc notes, no ground-truth TPS, and only information available before the prediction time.
- The paper emphasizes AUPRC as the most relevant metric under severe class imbalance, but on the public CHB-MIT and Siena tables NeuroNTP is not best in AUPRC; CSBrain has higher AUPRC on both datasets. NeuroNTP appears strongest in AUROC and balanced accuracy under the reported protocols. Thus, the SOTA claim should be metric-specific rather than global.
- The next-token prediction objective needs clearer parameterization. Equation (3) defines a weighted multi-quantile loss over embedding dimensions but appears to use a single prediction for all quantiles. Unless the model outputs separate quantile-specific embeddings, it is unclear how this constitutes a proper multi-quantile distributional prediction objective. The authors should clarify whether the output head predicts one embedding, multiple quantile embeddings, or a parameterized distribution.
Questions
- Which clinical markers and notes are used as input during KUK inference? Are seizure-related markers such as Anfall, EEG-Beginn, EEG-Ende, Anfallsbeginn, or Anfallsende ever visible to the model when predicting ictal/non-ictal labels?
- Are clinical notes guaranteed to be available before the prediction time? Please clarify whether notes are real-time annotations or whether any are post-hoc annotations written after clinical review.
- How is TPS computed at validation/test time? Does it use ground-truth prior seizures, model-predicted prior seizures, or external clinical records? Please report results without TPS or with TPS estimated only online.
- Can the authors report a strict deployable setting? This should use only biosignals available before the prediction time, with no seizure markers, no post-hoc notes, and no ground-truth TPS.
- How is the weighted multi-quantile next-token loss parameterized? Does the model predict one embedding shared across all quantiles, or separate quantile-specific embeddings?
Limitations
The authors discuss several useful limitations, including the inability to release the private KUK dataset, the need for fixed-rate resampling, possible token-ordering inductive bias, memory constraints for edge deployment, and the need for interpretability. These are useful, but they do not address the most important unresolved limitation: the possibility that multimodal performance depends on clinical annotations or seizure-derived temporal context unavailable in prospective deployment. The limitations section should explicitly discuss clinical-marker availability, seizure-delimiter exclusion, TPS assumptions, and the difference between retrospective annotation-rich evaluation and prospective sensor-only deployment. The paper should also more directly discuss false alarms, missed seizures, alarm fatigue, clinical operating thresholds, and privacy risks from pretrained representations derived from clinical text.
Final justification
I am raising my score from borderline reject to borderline accept. My original score was driven primarily by uncertainty about whether clinical markers, post-hoc notes, or ground-truth TPS contributed to the main reported results. The rebuttal clarifies that the principal biosignal-only KUK results and all CHB-MIT/Siena evaluations exclude these inputs, substantially resolving that concern. The authors also satisfactorily clarify the loss parameterization and agree to make the SOTA claims metric-specific.
Some uncertainty remains because the online self-predicted-TPS evaluation is still planned rather than reported, and EEG-phenomena annotations should not be labelled as deployment-valid unless their prospective availability is established. More broadly, several novelty, attribution, and reproducibility concerns raised across the reviews remain only partially addressed. Nevertheless, I find the paper interesting overall.
Formatting concerns
No major formatting concerns.
3 comments
Rebuttal
We thank the reviewer for an exceptionally precise reading. The central concern — that multimodal gains might depend on information unavailable at deployment — is well taken, and we realize the manuscript did not state the evaluation protocol clearly enough. We first clarify that protocol, then answer each question.
Evaluation protocol (will be stated explicitly in §5). All reported evaluations use biosignal-only input except where a row is explicitly designated multimodal. Clinical text, markers, notes, and TPS enter only two clearly-marked settings: KUK detection with clinical text (one row of Table 1), and KUK seizure prediction (Table 8). All CHB-MIT and Siena results — detection, linear probing, marker reconstruction — are biosignal-only (EEG on the montages of Appendices F.1/F.2; no TPS, markers, notes, or metadata). Our SOTA and generalization claims rest on these external, biosignal-only results; the backbone is multimodally pretrained but inference is unimodal. We will make this explicit in the main text and limitations.
Q1 — Which markers are visible during KUK inference?
The submitted Table 1 "w/ clinical text" row contained behavioural, technical, and EEG-phenomena markers, and no seizure-event or delimiter markers (Anfall, EEG-Beginn, EEG-Ende, etc. were excluded from input). To make this fully transparent we will replace that single row with a marker-group decomposition:
| Marker groups added | BACC | AUPRC | AUROC |
|---|---|---|---|
| none (biosignal-only) | 71.5 | 52.7 | 84.2 |
| + behavioural/general/technical | 74.7 | 60.7 | 87.0 |
| + EEG phenomena (= submitted Table 1) | 85.3 | 79.3 | 88.4 |
| + seizure-event markers | 90.7 | 86.7 | 94.3 |
The final row quantifies the contribution of seizure-derived annotations, which we agree are not available prospectively; it will be reported separately and labelled as annotation-assisted retrospective review, not deployment-valid. The biosignal-only row remains the deployable configuration and already exceeds every baseline in Table 1.
Q2 — Are notes available before prediction time?
KUK notes are timestamped clinical entries made during monitoring. We do not currently distinguish, per note, real-time entry from later review-time edits, and we will not claim all notes are strictly real-time. Because notes enter only the two designated multimodal inference settings and never the biosignal-only results, this does not affect the CHB-MIT/Siena claims or the biosignal-only KUK row. We will state this limitation explicitly.
Q3 — How is TPS computed at test time?
TPS is used only in the multimodal prediction setting (Table 8), never in detection and never on the public benchmarks. Only there it is computed from ground-truth prior seizure timestamps. We agree this is not prospectively faithful for fully autonomous deployment, though it remains a relevant setting for standard clinical workflows that feature human-in-the-loop annotations. To address the autonomous case, we are adding a variant in which the TPS timer is reset from the model's own predicted prior seizures (online, causal), and will report it alongside the ground-truth-TPS and no-TPS configurations so the gap is visible. Detection, linear probing, marker reconstruction and all external results contain no TPS information. We will update the manuscript to reflect this precisely (lines 166-169).
Q4 — Can you report a strictly deployable setting?
Yes — the biosignal-only results already are that setting: CHB-MIT and Siena detection (Tables 4–5, 9), KUK detection biosignal-only (Table 1, row above), and the biosignal-only prediction row in Table 8 all use only sensor data available before prediction time, with no seizure markers, no notes, no ground-truth TPS. We will foreground this framing. In addition, we will report the self-predicted-marker / self-predicted-TPS configurations above, approximating a closed-loop deployment where the system recirculates its own outputs.
Metric-specific SOTA
We agree and will revise the abstract and §5.3 accordingly: NeuroNTP achieves the best AUROC and balanced accuracy on CHB-MIT and Siena; CSBrain attains higher AUPRC on both. We will state this metric-specifically rather than as a global claim. We note one measurement subtlety: the reference protocol (Appendix F.1) augments seizure regions with overlapping windows, which shifts the acquisition-time base rate; as AUPRC is base-rate dependent while AUROC is not, AUPRC under this protocol does not reflect prevalence-faithful precision. We will make this explicit rather than rely on it, and where feasible report the reference-protocol model on a non-augmented test split.
Additionally, we identified a labelling inconsistency in the reference CHB-MIT protocol stemming from the same augmentation step: the main segmentation loop labels a window positive only if it contains a seizure start/end boundary, so windows falling entirely inside a seizure may remain labelled negative; augmentation then generates additional overlapping windows around and within seizures and labels all of these positive. As a result, the same ictal signal can appear as both a negative (unaugmented) and a positive (augmented) example, i.e. contradictory supervision for contained ictal regions. Relabelling all ictal windows as positive resolves this inconsistency and yields an AUPRC of 55.6% under the same (windowed) protocol, compared to the 51.6% AUPRC reported for CSBrain; we note we cannot confirm whether CSBrain's reported number reflects the reference protocol as implemented or an adjustment for this same labelling issue (Appendix F.1).
Parametrization of multi-quantile loss
The output head predicts a single embedding, with one shared prediction across the quantile set. The weighted-quantile formulation was retained to support asymmetric weightings, which we explored during development; for the final pretraining we selected the symmetric quantile set and weights reported in Appendix K. We agree with the reviewer that, in this symmetric single-prediction configuration, Eq. (3) reduces to a robust L1-type regression target rather than a genuine multi-quantile distributional objective. We will correct the description in §4.3, and revise the related "distributional prediction" characterization accordingly. Training and all reported results are unchanged, as the implemented loss is exactly the one described.
Limitations
We will expand the limitations section to state directly: which markers are and are not available at inference, the exclusion of seizure delimiters from deployable evaluation, the TPS provenance assumption, and the distinction between retrospective annotation-rich evaluation and prospective sensor-only deployment. We will also add discussion of false alarms, missed detections, alarm fatigue, operating-threshold selection, and privacy risks from representations pretrained on clinical text.
A representation-transfer finding we will promote
Directly relevant to this concern: a backbone pretrained multimodally but evaluated biosignal-only substantially outperforms one pretrained biosignal-only -- linear probing on identical biosignal input renders on Siena, AUROC 91.5 vs 88.9 and AUPRC 30.9 vs 26.3; consistent on CHB-MIT with AUROC 92.5 vs 88.9 and AUPRC 39.11 vs 17.59 and KUK (Appendix J, lines 979–983). We will promote this from the appendix into Table 3 and include the comparison for all three datasets. We will release the weights for both pretrained model variants.
Thank you for the detailed and transparent response. The rebuttal substantially clarifies my main concern regarding whether the reported gains depend on information unavailable at deployment.
Q1 — Which markers are visible during KUK inference?
Your clarification that the submitted “with clinical text” result excluded explicit seizure-event and delimiter markers such as Anfall, EEG-Beginn, and EEG-Ende addresses my main concern here. The proposed marker-group decomposition is useful, particularly because it separates the deployment-valid configuration from the retrospective annotation-assisted setting. Please include this distinction clearly in the revised paper and specify the marker groups sufficiently for readers to understand what information is available in each condition. I consider Q1 largely resolved.
Q2 — Are notes available before prediction time?
Thank you for stating clearly that you cannot guarantee that every note was available in its final form before prediction time. This answers my question. Therefore, I believe the appropriate interpretation is that note-assisted results are retrospective or annotation-assisted, rather than strictly prospective. Since the main biosignal-only results do not seem to use these notes, I do not view this as affecting the core external-transfer claims. I consider Q2 resolved, subject to the promised clarification in the manuscript.
Q3 — How is TPS computed at test time?
The response makes clear that the submitted multimodal prediction result uses ground-truth prior seizure timestamps, whereas detection and the public-benchmark evaluations do not use TPS. This resolves the ambiguity in the current manuscript. The ground-truth-TPS configuration should be clearly described as an annotation-assisted or human-in-the-loop setting rather than a fully autonomous one. The planned online self-predicted-TPS result would be a useful additional evaluation of the autonomous setting, but I do not view it as necessary for validating the existing biosignal-only result. I consider Q3 largely resolved.
Q4 — Can you report a strictly deployable setting?
The clarification that the KUK biosignal-only detection and prediction rows, as well as all CHB-MIT and Siena evaluations, use no clinical markers, notes, or ground-truth TPS substantially addresses my central deployment concern. I would suggest making the model-visible inputs explicit in the corresponding table captions and consistently distinguishing biosignal-only, annotation-assisted, and ground-truth-history settings to further improve clarity. I consider Q4 resolved.
Q5 — Multi-quantile next-token loss.
Thank you for confirming that the model predicts a single shared embedding and that, with the final symmetric quantile configuration, the loss reduces to a robust L1-type objective rather than a genuine multi-quantile distributional prediction objective. This fully answers my question. The manuscript should correct the terminology and equation discussion accordingly, but I do not view this clarification as requiring the experiments to be rerun. I consider Q5 resolved.
Metric-specific SOTA claim.
I also appreciate the commitment to revise the SOTA claim so that it is metric-specific: NeuroNTP is strongest in AUROC and balanced accuracy under the reported public-dataset protocols, while CSBrain has the higher originally reported AUPRC. The corrected-label CHB-MIT analysis is interesting, but the resulting AUPRC should not be directly ranked against CSBrain unless both models are evaluated under the same corrected protocol.
Overall, the rebuttal resolves most of my original concerns. The planned online self-predicted-TPS evaluation would be a useful addition for characterising a fully autonomous setting, while the existing biosignal-only prediction result already provides a no-TPS configuration. The revised manuscript should clearly distinguish biosignal-only, annotation-assisted, and human-in-the-loop settings.
Thank you for the close reading across both rounds and for confirming resolution on each point. We will make every distinction you ask for explicit in the revision. Concretely:
Consistent, explicit settings distinction. We will make the model-visible inputs explicit and consistent for every reported result, so that readers can see at the point of reading what each configuration has access to. We will apply this distinction uniformly across the text, table captions, and figure legends, and finalize concise labels for these settings in the revision.
Q1 (KUK marker visibility). Thank you for confirming that the marker-group decomposition is valuable. We will include it in the revised paper and specify the groups in enough detail for readers to see exactly what is visible in each condition, explicitly separating the deployment-valid configuration (EEG phenomena; seizure-event and delimiter markers such as Anfall, EEG-Beginn, EEG-Ende excluded) from the retrospective annotation-assisted setting.
Q2 (notes). We will label the note-assisted results accordingly, and note that the biosignal-only and external-transfer results do not use these notes.
Q3 (TPS at test time). We will describe the ground-truth-TPS multimodal prediction configuration as annotation-assisted / human-in-the-loop, and state clearly that detection and the CHB-MIT/Siena evaluations use no additional modalities than the biosignal channels in the reference protocols. The online self-predicted-TPS evaluation remains planned as a characterization of the fully autonomous setting.
Q4 (deployable setting). Table captions for the KUK biosignal-only detection and prediction rows and for all CHB-MIT/Siena results will state explicitly that no clinical markers, notes, or ground-truth TPS are used, under the taxonomy above.
Q5 (multi-quantile loss). We will correct the terminology and the Eq. 3 discussion to describe the objective accurately as a robust L1-type loss over a single shared predicted embedding, rather than multi-quantile distributional objective.
Metric-specific SOTA claim. We will state the claim metric-specifically; NeuroNTP is strongest in AUROC and balanced accuracy under the reported public-dataset protocols, with CSBrain higher in AUPRC.
We appreciate the constructive engagement, which has materially sharpened how the deployment settings are presented.
- Rating
- 3/6
- Confidence
- 5/5
- Quality
- 2/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 1/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper proposes NeuroNTP, a multimodal pre-training approach seizure detection (or prediction). The pre-training is done using the KUK dataset, which contains 150K hours of EEG, ECG, SpO2, and clinical text data. The model converts inputs into a shared token space using a multimodal tokenizer, and processes the flattened tokens by xLSTM using next-token prediction as the main objective, combined with auxiliary tasks (e.g., token type classification). The model is evaluated on multiple downstream tasks within the KUK dataset and two public EEG benchmarks.
Strengths and weaknesses
Strengths
- The paper presents a pre-trained model that achieves strong performance on multiple benchmarks by leveraging a large-scale dataset.
- The proposed model is lightweight, which makes it potentially useful for real-world deployment.
Weaknesses
- Technical novelty: The paper presents self-supervised pre-training, a multimodal architecture, montage-geometry generalization, and scale validation as its main contributions. However, as far as I understand, the pre-training objective is mainly next-token prediction, the multimodal design aligns different tokens in a shared sequence, and the montage-geometry assignment is also based on existing techniques. While these are meaningful design choices for practitioners, the paper would benefit from a clearer explanation of what is technically novel compared with prior work, beyond combining and scaling existing methods.
- Montage-geometry generalization: This is presented as one of the main contributions, but it is not sufficiently discussed in the main body. Since this appears to be an important claim, the paper should explain the method and its empirical impact in more detail.
- Pre-training objective: As shown in Table 6, most existing works use masked reconstruction or contrastive learning, whereas this paper mainly uses next-token prediction. If one of the key findings is that next-token prediction is a better objective for this setting, the paper should provide a deeper explanation of why it works better, ideally with comparisons against alternative objectives. It would also be helpful to discuss when next-token prediction should be preferred over masked reconstruction or contrastive learning (for future foundation model designers/researchers).
- Source of performance gains: It is unclear whether the main gains come from the pre-training objective, the network architecture, or the scale and quality of the pre-training dataset. For the public benchmark evaluations, are the comparisons conducted using the same modalities and the same pre-training data? If not, the performance improvement may be largely attributable to the scale and quality of the pre-training data rather than the proposed methodological components. Additional experiments using different pre-training datasets would help disentangle the effects of data scale, data quality, architecture, and objective design.
- Alternative models: If the quadratic inference cost is the main problem, it would be useful to discuss why the proposed architecture is preferred over recent sub-quadratic sequence models, such as Mamba or other state-space models.
- Related work (multimodal) and baselines: The related work and experiments do not cover several multimodal physiological foundation models (including EEG). While these works may differ in preprocessing and downstream tasks, the central goal of a foundation model is to learn representations that generalize across diverse tasks and settings. Therefore, I believe at least some of these models could be adapted or compared in this setting.
[1] Thapa, et al. "A Multimodal Sleep Foundation Model for Disease Prediction." Nature Medicine, 2026.
[2] Chen, et al. "PhysioWave: A Multi-Scale Wavelet-Transformer for Physiological Signal Representation." NeurIPS, 2025.
[3] Liu, et al. "Frequency-Aware Masked Autoencoders for Multimodal Pretraining on Biosignals." arXiv, 2024.
[4] Yoon, et al. "Beyond Hearing: Learning Task-Agnostic ExG Representations from Earphones via Physiology-Informed Tokenization." ICLR, 2026.
[5] Jiang, et al. "Towards Robust Multimodal Physiological Foundation Models: Handling Arbitrary Missing Modalities." arXiv, 2025.
[6] Xiao, et al. "BrainOmni: A Brain Foundation Model for Unified EEG and MEG Signals." NeurIPS, 2025.
[7] Luo, et al. "Toward Foundation Model for Multivariate Wearable Sensing of Physiological Signals." ACM TCH, 2026.
[8] Fang, et al. "Promoting Cross-Modal Representations to Improve Multimodal Foundation Models for Physiological Signals." AIM-FM, 2024.
Questions
Please see the weaknesses for my main questions and concerns.
Limitations
yes
Final justification
My concerns (2, 4, 5) are partially resolved. But some of the issues remain, I will increase my score to borderline reject.
Formatting concerns
No
4 comments
Rebuttal
We thank the reviewer for the rigorous technical read. We address your specific concerns below.
1. Technical Novelty
Atomic components of our system (xLSTM, NTP, 3D-pos-embeddings) are established in isolation. We will clarify in the manuscript that our novelty is not the invention of these underlying components.
Our core technical contribution is a unified multimodal epilepsy foundation model designed specifically for infinite-horizon, causal, multimodal streaming at constant memory cost. We enable this with a novel composite loss formulation where proximity-shaped supervision (TTS/TPS) structurally forces the latent space to prioritize sparse clinical transitions over stationary background noise. We point to Reviewer s5Th, who explicitly validated the novelty of this integration, noting that this is "the first work that combines a variety of different data such as eeg + text + SpO2 + ekg in a unified training scheme"
Proximity-Shaped Supervision. Our auxiliary objectives force the latent space to organize around clinical events by temporal distance to seizure onset, independent of the specific data source used to derive that distance. In a detection experiment using biosignal-only input, removing the auxiliary heads during pre-training for Time-to-Seizure (TTS) degrades AUPRC by 11.2% (44.2% → 33.0%), and removing Time-Past-Seizure (TPS) degrades it by 6.7% (44.2% → 37.5%) — the two largest ablation effects in Table 13. This isolates the contribution to the supervision mechanism rather than to the KUK annotations themselves, which we agree is the more precise framing of the novelty.
Beyond the specific instantiation for seizure detection, we believe the underlying design choices generalize, though we want to be careful to flag this as a scoped implication rather than a demonstrated result:
Self-supervised pretraining scheme (MMT → NTP → AUX). The three-stage scheme — multimodal tokenization, causal next-token pretraining, then proximity-based auxiliary supervision — is not simply a collection of independently-motivated components but a coupled design: MMT establishes a shared token space across modalities, NTP provides a modality- and architecture-agnostic pretraining objective over that space, and AUX shapes the resulting latent geometry around clinically meaningful events. We show this concretely for seizure analysis; the same scheme could plausibly apply to other time-series domains where proximity to an event of interest (e.g., onset of an arrhythmia, a desaturation event, a neruological deterioration) is informative for representation learning, though we have not evaluated this outside epilepsy.
We will incorporate this clarified framing into the introduction of the revised manuscript.
2. Montage-geometry generalization
We agree this belongs in the main body and will promote Appendix J.2. On evidence: our linear-probing results (Table 3) use a fully frozen backbone, including a frozen multimodal tokenizer, so transfer from the pretraining 10–20 montage to the CHB-MIT 16-channel bipolar montage and the Siena 19-channel montage is performed without gradient updates to any montage-dependent parameters electrode geometry enters only through the fixed 3D-coordinate encoding. CHB-MIT is a demanding test, as the bipolar "double-banana" differs substantially from the KUK acquisition montage.
We will (i) state precisely which parameters are frozen versus initialized in the zero-shot and finetuned regimes, (ii) report the empirical impact in the main body, (iii) add a leave-montage-out evaluation isolating the geometry encoding, and (iv) position against the spatial-encoding work (seegnificant, PopT, BaRISTA) noted by Reviewer s5Th.
3. NTP vs MAE
We do not claim that causal Next-Token Prediction (NTP) is universally superior to Masked Autoencoding (MAE) or contrastive learning. However, our objective is specifically for causal streaming.
- By flattening the timestep and enforcing causal modeling, every prefix within a timestep serves as a valid state to predict from.
- Adapting this exact multimodal, timestep-flattened architecture to standard bidirectional MAE is non-trivial and fundamentally alters the streaming objective. We will leave this adaptation to future comparative work.
4. Scale vs Architecture
To disentangle the performance delta between dataset scale, dataset quality, and architecture, we clarify the following:
- Modality Parity: For the downstream public benchmarks (CHB-MIT and Siena), all baselines and NeuroNTP evaluations were conducted using strictly identical modalities (EEG-only) and identical channel subsets, as detailed in Appendices F.1 and F.2.
- Data Scale Isolation: We isolated the effect of the KUK dataset by pretraining NeuroNTP from scratch on the public TUSZ dataset. This variant still achieves 93.0% AUROC on CHB-MIT, proving the architecture scales effectively independent of the private pretraining data.
- Modality Isolation: As detailed in Appendix J, multimodal pretraining yields a 79.34% AUROC under biosignal-only linear probing, whereas strictly biosignal-only pretraining collapses to 61.25%. We extended this comparison of multimodal-pretrained and biosignal-pretrained models to the external datasets. Linear probing on identical biosignal-only input renders on Siena, AUROC 91.5 vs 88.9 and AUPRC 30.9 vs 26.3; consistent on CHB-MIT with AUROC 92.5 vs 88.9 and AUPRC 39.11 vs 17.59.
- Scaling Proxy: The controlled 25/50/75% data-fraction study is actively computing and will be included in this discussion as well as in the final manuscript. As an immediate proxy, we will include intermediate linear probing metrics tracked across pretraining epochs. See Q1a Reviewer s5Th.
5. Alternative Sub-Quadratic Architectures
The decision to utilize xLSTM over state-space models (SSMs) like Mamba was driven by literature demonstrating xLSTM's superior performance for associative recall tasks, while still maintaining strictly constant memory scaling for streaming inference [1, 2]. We will add an in depth architectural justification including references.
6. Generalization across diverse Tasks
We explicitly frame NeuroNTP as a multimodal foundation model for epilepsy, rather than a generic model designed to solve orthogonal BCI tasks.
Our scope here is deliberately continuous seizure-related monitoring and its downstream tasks; adapting these models to that setting is valuable but out of scope, and our released weights are intended to make such comparison straightforward.
While exploring the model's zero-shot generalization to unrelated physiological tasks is an interesting benchmark of representational breadth, it falls outside the operational scope of a domain-specific clinical system. By open-sourcing the tokenizer, weights, and inference code, we provide the necessary infrastructure for the community to conduct these broader, test-of-time capability evaluations.
[1] Beck, M., Pöppel, K., Spanring, M., Auer, A., Prudnikova, O., Kopp, M., ... & Hochreiter, S. (2024). xlstm: Extended long short-term memory. Advances in Neural Information Processing Systems, 37, 107547-107603.
[2] Podest, P., Pichler, M., Bürger, E., Zólyomi, L., Voggenberger, B., Berghammer, W., ... & Hochreiter, S. (2026). TiRex-2: Generalizing TiRex to Multivariate Data and Streaming. arXiv preprint arXiv:2607.01204.
-
Thank you for clarifying and providing the additional results. The emphasized proximity-shaped supervision through TTS/TPS appears to be an important part of the contribution, and Table 13 provides useful evidence that it improves seizure-detection representations. Given this emphasis, I encourage the authors to revise the paper's framing so that this component and its role are clearly presented. At the same time, because TTS/TPS targets require seizure-timing annotations and are closely aligned with the downstream task, the paper should discuss the supervision and annotation requirements explicitly, particularly if this formulation is positioned as the core methodological novelty or as a pre-training strategy.
I view the exact combination of modalities and the causal epilepsy-monitoring setting as a useful framework. However, multimodal physiological pre-training itself has been explored in representative models (e.g., SleepFM). Likewise, the three-stage scheme of tokenization, pre-training, and supervision is common in multimodal foundation models. Therefore, the paper would benefit from positioning its contribution more specifically as the integration of causal streaming and seizure-proximity supervision for multimodal epilepsy monitoring, while clearly distinguishing this application-specific contribution from broader claims of a new multimodal pre-training paradigm. Thus, the rebuttal partially addresses my novelty concern through the TTS/TPS component, while the broader novelty claims remain insufficiently differentiated from prior work.
-
Promoting the montage-geometry method and its empirical impact to the main text, together with the proposed leave-montage-out evaluation, would adequately address this concern.
-
I agree that NTP provides a natural inductive bias for predictive tasks and causal streaming. However, masked reconstruction and contrastive learning have also been successfully used for diagnosis and prediction in health applications. Moreover, masked reconstruction can be adapted to the same causal backbone, for example by reconstructing masked channels or modalities using only the available prefix. Therefore, a controlled comparison with alternative objectives would still help clarify the specific benefit of NTP, although I appreciate the authors' motivation for this design choice.
-
These provide useful evidence that the gains are not solely attributable to the private KUK dataset. Together with the modality-ablation results and the planned data-fraction study, this largely addresses my concern regarding the source of the performance gains.
-
Thank you for clarifying the motivation for xLSTM. The rebuttal provides a reasonable rationale for continuous seizure monitoring. Adding this architectural justification and relevant references would partially address my concern.
-
I was not requesting that NeuroNTP be evaluated on unrelated physiological or BCI tasks. Rather, my question was whether existing multimodal physiological foundation models could be adapted and evaluated on the same seizure-related downstream tasks. Therefore, clarifying the epilepsy-specific scope does not fully address the baseline concern, although I agree that evaluation on unrelated tasks is unnecessary. At minimum, the paper should discuss the applicability of these models and include feasible comparisons with the most relevant ones.
We thank the reviewer for the thoughtful replies and for the constructive framing, which we fully adopt.
- Novelty
- Reframing the core contribution: We will present causal streaming NTP combined with seizure-proximity supervision (TTS/TPS) as the central methodological component early in the text, rather than leaving it to be inferred from the ablations.
- Clarifying supervision requirements: We will explicitly state that TTS/TPS require seizure-timing annotations during pretraining. Crucially, we will emphasize that downstream inference remains strictly biosignal-only. We will also expand Appendix H (TUSZ reproduction) to detail how these annotations are derived, proving this data requirement is readily satisfiable using standard public datasets outside KUK.
- Narrowing the novelty claim: we accept that multimodal physiological pretraining (e.g., SleepFM) and the tokenize→pretrain→supervise scheme are established. We will (i) credit this prior work, (ii) drop the claim of a new general multimodal pretraining paradigm, and (iii) state our contribution specifically as the integration of causal streaming, temporally-aligned clinical text, and seizure-proximity supervision for multimodal epilepsy monitoring.
-
Thank you, this matches what we will do. We will promote the montage-geometry method to the main text consolidated with the clarifications related to Q3 of reviewer s5Th, and add a leave-montage-out evaluation that isolates its empirical impact.
-
We agree this is a fair point. The reviewer is right that masked reconstruction and contrastive objectives have been used effectively for diagnosis and prediction, and that masked reconstruction can be adapted to a causal backbone (e.g., prefix-conditioned reconstruction of masked channels or modalities). A controlled, matched-compute comparison across objectives would indeed sharpen the specific benefit of NTP. Because such a comparison requires pretraining separate models under each objective at matched compute and architecture - being non-trivial within the rebuttal window - we scope it as future work, and will extend the framework to support alternative objectives (including causal prefix-masked reconstruction) so these comparisons can be run cleanly. In the revision we will correspondingly motivate NTP by its fit to the deployment setting - causal streaming inference, stateful updates over long recordings.
-
Thank you. We will present these results - the public-dataset reproduction, the modality ablations, and the data-scaling study - with enhanced clarity and context in the revised manuscript, so that the evidence bearing on the source of the performance gains is easy to locate and interpret.
-
We thank the reviewer for confirming our rationale. As requested, we will incorporate this architectural justification directly into the main text.
-
Applicability of existing Multimodal Baselines Given the rapid development and the wide field, we thank the reviewer for pointing out these works. We will discuss their applicability to our seizure detection and prediction tasks. If possible, we will also run linear-probing on readily available foundation models to assess and compare their generalization to these tasks. We extend our Table 6 (Recent Brain Signal Foundation Models) to include the following:
| Model | Backbone (Complexity) | Objective | Modality | Montage Agnostic | Pretraining Data | Weights |
|---|---|---|---|---|---|---|
| SleepFM | 1D CNN () | Contrastive Learning | EEG+EOG+EMG+ECG+Resp. | ✗ | Private PSG (≈100k h) | ✓ |
| BrainOmni | Criss-Cross Trans. () | Masked Code Pred. | EEG+MEG | ✓ | Public EMEG (≈2.6k h) | ✓ |
| Biosignal MAE | Transformer () | MultiMAE | EEG+ECG+EOG+EMG | ✗ | PhysioNet18 (≈15k h) | ✗ |
| PhysioOmni | VQ-VAE Trans. () | Recon. + Masked Code Pred. | EEG+ECG+EOG+EMG | ✗ | Public + Private (≈25k h) | ✓ |
| NeuroNTP | xLSTM () | Causal NTP + Aux. | EEG+ECG+SpO$_2$+text | ✓ | Private KUK (>150k h) | ✓ |
I thank the authors for their response to my comments. Although my concerns have been partially addressed, some issues remain. Therefore, I will raise my score to weak reject.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
We thank the Area Chair for the precise synthesis and the clear roadmap for acceptance. We have systematically addressed the core requirements across the individual rebuttals. Below is the executive summary of the new evidence and structural revisions we commit to for the final manuscript:
1. Deployment-faithful evaluation (strict Biosignal-Only)
Causal validity and strict biosignal evaluation is the concern we most want to correct a framing on, because we believe it rests on an under-stated protocol rather than a limitation of the results. Our central claims - SOTA transfer on CHB-MIT and Siena on AUROC - are already strictly biosignal-only: EEG input alone, with no clinical text, no markers, no notes, no TPS, no metadata (Appendices F.1/F.2). The annotation-dependent configurations are confined to two explicitly-labelled KUK settings (one Table 1 detection row; Table 8 prediction) and are not part of the generalization claim. To make this explicit in the main text, we will:
2. Attribution of performance gains.
We disentangle performance as follows.
3. Reposition novelty and montage generalization.
We concede the atomic components are established and reposition the contribution precisely.
4. Reproducibility, Quantile loss, SOTA, comparability.
A Final Note of Gratitude Finally, we want to thank the AC and reviewers for their valuable time. We are aware that this level of deep, constructive engagement is increasingly rare. The rigorous critique and actionable feedback have improved the structural rigor and clarity of this work. We deeply appreciate the effort invested by the reviewers and the opportunity to strengthen this manuscript.