TL;DR. This paper estimates human motion from video with two specialized models: one deterministically predicts the stable torso and root motion, while the other probabilistically models the more ambiguous full-body articulation.

Abstract. Human Mesh Recovery (HMR) is fundamentally ambiguous: under occlusion or weak depth cues, multiple 3D bodies can explain the same image evidence. This ambiguity is not uniform across the body, as torso pose and root structure are often relatively well constrained, whereas distal articulations such as the arms and legs are more uncertain. Building on this observation, we propose \textbf{FactorizedHMR}, a two-stage framework that treats these two regimes differently. A deterministic regression module first recovers a stable torso-root anchor, and a probabilistic flow-matching module then completes the remaining non-torso articulation. To make this completion reliable, we combine a composite target representation with geometry-aware supervision and feature-aware classifier-free guidance, so that well-observed body parts remain accurate while ambiguous articulations can be completed without collapsing to deterministic averages. We also introduce a camera-aware synthetic data pipeline that provides the paired image-camera-motion supervision under diverse viewpoints. Across camera-space and world-space benchmarks, FactorizedHMR improves articulation recovery and reduces drift relative to strong baselines, especially in ambiguous scenes.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
24 Apr 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]—[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:42 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

FactorizedHMR decomposes video HMR into deterministic torso/root estimation and probabilistic flow-based completion of non-torso articulation and world motion. It combines masked flow matching, geometry-aware supervision, classifier-free guidance, and camera-aware synthetic training data. The method reports improvements on camera- and world-space benchmarks, with its clearest gains under heavy occlusion, although improvements over GVHMR on standard benchmarks are mixed and come at substantially higher computational cost.

The body-part uncertainty factorization is intuitive and well motivated. The framework is technically coherent, the synthetic-data pipeline is useful, and the strong 3DPW-XOCC results support the method’s value in occlusion-heavy settings. Reviewers ov1a and P753 also find the torso-region improvements and qualitative results convincing.

The central factorization claim is not isolated by a controlled comparison against deterministic, fully probabilistic, or single-stage alternatives with matched representations and conditioning. Baseline evaluation is also unclear: reported GENMO/GVHMR numbers differ from their original papers, GVHMR is absent from the main occlusion comparison, and direct generative-HMR baselines such as RoHM are missing. Some novelty claims around masked generation and partial CFG appear overstated. Finally, several standard-benchmark and temporal-smoothness results regress, while inference is about 9.5× slower and uses 3.5× more memory than GVHMR.

In the rebuttal, please respond to:

  1. Provide a controlled ablation that isolates the benefit of deterministic/probabilistic factorization, ideally comparing matched deterministic and probabilistic Stage-2 variants.
  2. Reconcile the GENMO/GVHMR metric discrepancies and provide GVHMR on 3DPW-XOCC and, if feasible, one direct generative-HMR comparison; otherwise qualify the comparative claims.
  3. Explain the standard-benchmark and temporal-smoothness regressions, and report the accuracy/runtime trade-off of the approximately 20-step variant suggested by the ablation.
  4. Clarify novelty relative to GVHMR and RoHM, soften claims for established masked-generation and CFG techniques, and provide essential missing implementation details.
Final justification

I have carefully read the authors’ response, follow-up clarifications, and the reviewers’ post-rebuttal assessments. I find that the response successfully addresses most of the decision-critical issues raised in my initial meta-review. Most importantly, the new controlled experiment shows that the proposed deterministic-torso/probabilistic-non-torso design outperforms matched deterministic, fully probabilistic, and part-aware single-stage alternatives, directly strengthening the central factorization claim (U2DP, ov1a, P753). The authors also clarify the GENMO/GVHMR reproduction protocols, add GVHMR results on the reconstructed 3DPW-XOCC protocol and best-effort generative-HMR comparisons, and appropriately qualify claims where protocols are not fully matched (U2DP, ov1a, P753). They further narrow the novelty claims around masked generation and partial CFG, acknowledge mixed standard-benchmark and temporal-smoothness results, and report a more practical 20-step inference configuration (P753).

The reviewers found the rebuttal materially effective. U2DP stated that both main concerns were satisfactorily addressed and maintained borderline acceptance; ov1a found the main technical concerns sufficiently addressed and updated to borderline accept; and P753 raised the score to accept after concluding that most concerns were resolved.

Some limitations remain: the PA-MPJPE improvement over the deterministic part-aware baseline is only 0.9, the XOCC and RoHM comparisons are protocol-limited, temporal and contact-related metrics remain mixed, and even the 20-step configuration remains slower and more memory-intensive than GVHMR (U2DP, ov1a, P753). Nevertheless, the authors acknowledge these trade-offs and appropriately narrow the claims. The intuitive uncertainty factorization, coherent technical design, strong occlusion-heavy results, and useful synthetic-data pipeline constitute a meaningful contribution to video HMR. I therefore recommend acceptance as a poster.

Area Chair Fi1S · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

FactorizedHMR decomposes video HMR into deterministic torso/root estimation and probabilistic flow-based completion of non-torso articulation and world motion. It combines masked flow matching, geometry-aware supervision, classifier-free guidance, and camera-aware synthetic training data. The method reports improvements on camera- and world-space benchmarks, with its clearest gains under heavy occlusion, although improvements over GVHMR on standard benchmarks are mixed and come at substantially higher computational cost.

The body-part uncertainty factorization is intuitive and well motivated. The framework is technically coherent, the synthetic-data pipeline is useful, and the strong 3DPW-XOCC results support the method’s value in occlusion-heavy settings. Reviewers ov1a and P753 also find the torso-region improvements and qualitative results convincing.

The central factorization claim is not isolated by a controlled comparison against deterministic, fully probabilistic, or single-stage alternatives with matched representations and conditioning. Baseline evaluation is also unclear: reported GENMO/GVHMR numbers differ from their original papers, GVHMR is absent from the main occlusion comparison, and direct generative-HMR baselines such as RoHM are missing. Some novelty claims around masked generation and partial CFG appear overstated. Finally, several standard-benchmark and temporal-smoothness results regress, while inference is about 9.5× slower and uses 3.5× more memory than GVHMR.

In the rebuttal, please respond to:

  1. Provide a controlled ablation that isolates the benefit of deterministic/probabilistic factorization, ideally comparing matched deterministic and probabilistic Stage-2 variants.
  2. Reconcile the GENMO/GVHMR metric discrepancies and provide GVHMR on 3DPW-XOCC and, if feasible, one direct generative-HMR comparison; otherwise qualify the comparative claims.
  3. Explain the standard-benchmark and temporal-smoothness regressions, and report the accuracy/runtime trade-off of the approximately 20-step variant suggested by the ablation.
  4. Clarify novelty relative to GVHMR and RoHM, soften claims for established masked-generation and CFG techniques, and provide essential missing implementation details.
Final justification

I have carefully read the authors’ response, follow-up clarifications, and the reviewers’ post-rebuttal assessments. I find that the response successfully addresses most of the decision-critical issues raised in my initial meta-review. Most importantly, the new controlled experiment shows that the proposed deterministic-torso/probabilistic-non-torso design outperforms matched deterministic, fully probabilistic, and part-aware single-stage alternatives, directly strengthening the central factorization claim (U2DP, ov1a, P753). The authors also clarify the GENMO/GVHMR reproduction protocols, add GVHMR results on the reconstructed 3DPW-XOCC protocol and best-effort generative-HMR comparisons, and appropriately qualify claims where protocols are not fully matched (U2DP, ov1a, P753). They further narrow the novelty claims around masked generation and partial CFG, acknowledge mixed standard-benchmark and temporal-smoothness results, and report a more practical 20-step inference configuration (P753).

The reviewers found the rebuttal materially effective. U2DP stated that both main concerns were satisfactorily addressed and maintained borderline acceptance; ov1a found the main technical concerns sufficiently addressed and updated to borderline accept; and P753 raised the score to accept after concluding that most concerns were resolved.

Some limitations remain: the PA-MPJPE improvement over the deterministic part-aware baseline is only 0.9, the XOCC and RoHM comparisons are protocol-limited, temporal and contact-related metrics remain mixed, and even the 20-step configuration remains slower and more memory-intensive than GVHMR (U2DP, ov1a, P753). Nevertheless, the authors acknowledge these trade-offs and appropriately narrow the claims. The intuitive uncertainty factorization, coherent technical design, strong occlusion-heavy results, and useful synthetic-data pipeline constitute a meaningful contribution to video HMR. I therefore recommend acceptance as a poster.

Reviewer P753OpenReview ↗
Rating
5/6
Confidence
4/5
Quality
3/4
Clarity
2/4
Significance
3/4
Originality
2/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The paper proposes FactorizedHMR, a two-stage video HMR system motivated by the observation that reconstruction uncertainty is non-uniform across the body. Typically, the torso/root is well-visible and therefore well-constrained while other parts of the body are more ambiguous. Stage 1 is a transformer that deterministically regresses a "structural anchor" which consists of the torso's body posture, shape and the root trajectory in camera frame. Stage 2 is a masked conditional flow-matching module that completes the remaining 13 non-torso joint rotations, the joint locations themselves and the root trajectory in world frame. It is trained with joint-bone consistency loss, a 2D projection loss, and a classifier-free guidance variant. Training uses AMASS / BEDLAM / H36M / 3DPW plus newly synthesised videos. The results beat baseline methods on all datasets while being less runtime and memory efficient than related methods.

Strengths and weaknesses

Paper Strengths The factorisation of HMR uncertainty, torse & camera frame vs non-torso and world frame, is a useful framing and is empirically motivated by the appendix per-joint analysis. The 3DPW-XOCC results especially in Tab. 4 are strong, demonstrating that the method can indeed substantially improve recovery in case of heavy occlusions / degradations. The torso-region panel of Tab. 2 is convincing, as it consistently outperforms GVHMR across all datasets. The progressive ablation in Tab. 5 is mostly structurally clear and the the synthetic-data pipeline for data generation, while building upon pre-existing models, is a good contribution to the field.

Major Weaknesses

  1. Tab. 5 ablation is misleading. Row 1 ("Stage 1 Model") is degenerate, as the stage 1 model alone predicts only the torso anchor, so that the stage 2 model would be required to recover a complete body pose. Thus, the large gain of 25.1 PA-MPJPE from row 1 to row 2 is just coming from the fact that the stage 1 model is not capable of predicting the entire body. No row in the table compares masked CFM Stage 2 to a regression-based or diffusion-based Stage 2 with the same composite latent, mask, and conditioning.

  2. Two novelty claims overstate what the paper contributes against prior work. The masked path (Eq. 6), inference-time z_K re-imposition, and partial CFG together reduce to a masked diffusion recipe already used by, e.g., RoHM. Similarly, what Sec. 3.3 calls "feature-aware CFG" is a partial-condition CFG variant that drops observation-heavy conditions while keeping anchor ones is a well-known technique. Both claims should be softened or removed.

  3. Unflagged regressions. First, the paper attributes the worse PA-MPJPE in EMDB to a SMPL-vs-SMPL-X protocol mismatch. However, the same issue applies on RICH and 3DPW where Ours wins, so the explanation does not transfer cleanly and the regression is left effectively unaddressed. Second, several temporal-smoothness numbers in Tab. 3 are much worse than the baselines. These directly contradict the introduction's "temporally consistent video HMR" framing and weaken the paper's statement that world-space results as "broadly competitive".

  4. No generative-HMR baselines. ScoreHMR, GenHMR, RoHM, and others, are all cited in Sec. 2 but none appear in the experiments. RoHM in particular is the most direct masked-diffusion HMR baseline, it factorises trajectory vs local pose and refines them in stages, and the paper inherits its joint-position representation directly. Given that Contribution 2 is explicitly about probabilistic HMR via flow matching, the works lack any head-to-head comparison against this class of methods.

  5. Efficiency framing. Sec. 4.2 reports 3.92 s for a 1193-frame clip vs GVHMR 0.41s at 50 ODE steps, with 1057.0 MB peak GPU memory vs 303.6 MB, which is close to a 9.5x slowdown and a 3.5x memory increase. The paper presents this as 304.45 amortised fps, which might be technically correct but misleading about per-sequence latency for a video method. Fig. 7 also show Stage 2 quality saturates by roughly 20 ODE steps, with 20 actually best on PA-MPJPE. However, the main paper's numbers in Tabs. 1, 3, and 4 are reported at 50 steps. A 20-step variant would improve PA-MPJPE and improve efficiency, so it's not clear why it hasn't been used across experiments.

Minor Weaknesses

  1. Reproducibility gaps in the specifics. Rotation parameterisation (axis-angle vs 6D vs quaternion), learning rate, batch size, total iterations, CFG dropout rate during training, the projection-loss ramp schedule, individual loss weights across the multi-term geometry losses, training-mixture sampling weights, total parameter count, and the sliding-window / clip-length protocol are all not given. Thus, the method cannot be re-implemented from the paper alone.

  2. Limitations. The limitations paragraph is short and no failure cases are shown.

  3. Notation overloads. rho is reused for both the 3D robust penalty in Eq. 8 and the 2D pixel-space penalty in Eq. 9; K is reused for the "known" partition subscript in z_K and the camera intrinsics matrix in Pi_K (Eq. 9); t collides as frame-time index in Eq. 1 and as flow-matching time in Eqs. 6-7.

  4. Tab. 6 hip duplication. Left hip and right hip values are identical across all three datasets and the mean, while this is not the case for every other paired joint. Might be a copy paste error.

Overall The paper introduces an interesting framing, separating well-constrained torso from often ambiguous non-torso and world motion, and improves accuracy on the occlusion-heavy 3DPW-XOCC benchmark (Tab. 4) and on world-space MPJPE for EMDB and RICH (Tab. 3). However, the ablation does not isolate the central masked-CFM or feature-aware-CFG claims, the novelty framings are partially overstated, several regressions on EMDB PA-MPJPE and on temporal-smoothness metrics are left unaddressed, and the closest generative-HMR baselines are missing from the experiments.

Questions

What would most strengthen the paper: (a) a flow-matching vs regression vs diffusion Stage 2 comparison with identical input-output structure to clarify the Tab. 5 Row 1 ablation; (b) a numerical comparison to at least one direct generative-HMR baseline (RoHM in particular) on Tab. 3 or Tab. 4; (c) a 20-step ODE variant of the headline tables with reported runtime; and (d) somewhat weakening the novelty statements.

Limitations

The limitations paragraph is short and does not show any qualitative nor quantitative results, such as failure cases, per-joint error analysis, the results' variances, etc.

Final justification

I thank the authors for a thorough rebuttal that answers most of my concerns, such as the novelty claims, regressions, and the runtime cost related concerns. My one remaining doubt is the ablation (Tab. 5 Ablation), where their new comparison puts a plain deterministic single-stage baseline within only 0.9 PA-MPJPE of the full much more complicated system. However, as most concerns have been addressed, I'll raise my score to accept.

Formatting concerns

none

3 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We thank the reviewer for the detailed technical comments. We are encouraged that the review recognizes the useful framing, the empirical support from the per-joint analysis, the torso-region evidence in Table~2, and the relevance of occlusion-heavy robustness evaluation. Reviewer ov1a and Reviewer U2DP also recognized the core deterministic--probabilistic motivation, so we think the main contribution should remain this factorization, not the standalone novelty of every individual component. We agree that several claims should be softened, especially around masked path, feature-aware CFG, and broad metric claims.

Tab 5. Ablation

We agree with the reviewer that the wording around Table 5 was confusing. The Stage 1-only row should not be read as a full HMR competitor; it was meant as an anchor-only diagnostic showing what is recovered by the torso/root estimate alone. We will fix the caption and text so this row is not over-interpreted.

We also add the new Table 1 diagnostic below, which directly looks at the estimation paradigm. The important pattern is simple: det+det and prob+prob are both worse than our det+prob design, and the part-aware single-stage variants also do not reach ours.

Variant 3DPW MPJPE ↓ 3DPW PA-MPJPE ↓ 3DPW PVE ↓
Deterministic Torso prediction / Deterministic Non-Torso prediction 60.2 40.7 74.0
Deterministic Single-stage with part-aware loss 58.4 37.8 70.6
Probabilistic Torso prediction / Probabilistic Non-Torso prediction 68.9 45.5 81.0
Probabilistic Single-stage with part-aware loss 59.8 39.5 74.1
Ours: Deterministic Torso prediction / Probabilistic Non-Torso prediction 56.2 36.9 68.3
Table 1. Controlled factorization and Stage~2 diagnostics

This supports the same interpretation as Table 2, but in a more direct way. Making every variable deterministic loses the benefit of probabilistic generation for ambiguous non-torso parts; making every variable probabilistic also hurts because stable torso/root variables should act as an anchor. So we will keep the claim simple: Table 5 wording will be fixed, and Figure 1 shows that the mixed deterministic torso + probabilistic non-torso design is stronger than using one paradigm everywhere.

Novelty claims around masked path and feature-aware CFG

We agree with the reviewer that masked generation paths, re-imposing known coordinates during sampling, and partial-condition CFG should not be presented as isolated inventions. We do not claim that these are individually new contributions, and will soften the wording & cite related masked/guided generative reconstruction methods such as RoHM more explicitly.

Our key difference from RoHM is mainly the objective and the semantics of the mask. RoHM uses diffusion for robust motion reconstruction by denoising/infilling noisy or occluded motion estimates, with a global-trajectory/local-motion decomposition. In contrast, FactorizedHMR uses the mask to implement a deterministic--probabilistic division of labor inside video HMR: Stage 1 deterministically estimates the torso/root and camera-space structural anchor, while Stage 2 probabilistically completes only the ambiguity-prone non-torso articulation and world-motion variables. So the known subset in our masked path is not only a visible/noisy observation to preserve; it is a learned structural anchor that is deliberately excluded from generation.

We will revise the claim to a narrower statement: FactorizedHMR adapts masked conditional flow matching and partial CFG as implementation tools for a reliability-aware HMR factorization.

Regressions in PA-MPJPE and temporal smoothness

Our claim is not that FactorizedHMR dominates every metric: PA-MPJPE/PVE and contact-related metrics are mixed, while the clearer gains are in the region-wise torso/non-torso analysis and drift-sensitive W-MPJPE. We will revise broad statements such as “consistently outperforms prior methods” to “competitive on standard benchmarks with targeted gains,” and explicitly mention jitter/foot-sliding as remaining limitations. We will also avoid over-explaining this only by SMPL-vs-SMPL-X mismatch, and just describe the observed metric pattern directly.

Direct generative-HMR baseline comparison

GENMO is already included as a recent generative/probabilistic-style baseline, but we agree that the paper should mention other generative HMR methods more explicitly. We therefore add the following comparison on 3DPW, while being careful about protocol differences:

Method 3DPW MPJPE ↓ 3DPW PA-MPJPE ↓ 3DPW PVE ↓
RoHM 63.9 41.2 76.0
ProHMR - 59.8 -
Table 2: Scores from other probabilistic HMR pipelines, RoHM and ProHMR

For RoHM, the authors provide model weights, but not a straightforward evaluation path for video-level camera-coordinate metrics in the same setting we use, and RoHM also did not originally report 3DPW/EMDB/RICH comparisons. So we attempted our own reproduction with the released weights and our evaluation path. We will clearly mark this as our best-effort reproduction, since preprocessing and evaluation details may differ from what RoHM originally intended. For ProHMR, the PA-MPJPE number is the official score reported in its paper, not our reproduction. This comparison is not meant to claim a fully matched protocol for every generative HMR method, but to answer the reviewer that we did check available generative/probabilistic baselines and will state the compatibility limits rather than hiding them.

Efficiency framing and 20-step ODE variant

This is a fair point, and is partly already answered by the ODE-step sweep noted by the reviewer. In the main paper we merely used the 50-step CFG setting because it was the conservative setting for reporting, not because we believe it is the only practical one. Since Stage 2 is probabilistic, it does add runtime and memory compared to GVHMR, and we should state this more plainly.

Method / variant Total Latency (seconds) Steady Throughput (frames/sec) Peak GPU allocated memory (MB)
GVHMR 0.41 2708.41 303.6
Ours, recommended fast setting (20 steps, without CFG) 0.96 1248.05 651.9
Ours, conservative/default (50 steps, with CFG) 3.92 297.9 1057.0

Table 3: Runtime / Memory Analysis

We will re-check the results and move the practical lower-step setting discussion from Figure 7 into the main text. If the 20-step/no-CFG setting preserves the accuracy trend, we will report it as the faster operating point and keep the 50-step setting only as the conservative/default one. The revision will avoid making the runtime look better than it is, but also avoid making the 50-step number look like the required inference cost.

Reproducibility details

We will add the rotation parameterization, learning rate, batch size, number of iterations, and other relevant variables to training and inference to the appendix. We will also separate details needed to reproduce training from details needed only for evaluation. Baseline repository snapshots/checkpoints and preprocessing protocols will be documented with the evaluation details, while loss weights and optimization schedules will be documented with training. We will also fix the notation/minor errors pointed out by the reviewer, including robust penalty notation, camera/known-partition symbols, and frame-time vs flow-time notation.

Authors · CommentOpenReview ↗

Thank you again for the detailed technical review. We have tried to address the main issues you raised, including the wording around Table 5 ("Tab. 5 ablation is misleading"), the novelty scope of masked generation / partial CFG ("Two novelty claims overstate what the paper contributes against prior work."), the relation to RoHM ("No generative-HMR baselines"), and the runtime setting ("Efficiency framing").

If there are still concerns about the claim scope, the controlled diagnostic, or the implementation details, we would be happy to clarify them during the discussion period.

Authors · CommentOpenReview ↗

Thank you again for the detailed review. Since the discussion period is closing soon, we wanted to check whether there are any remaining concerns that we can still answer.

We would be happy to clarify any remaining point before the author-reviewer discussion period ends.

Reviewer ov1aOpenReview ↗
Rating
4/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
2/4
Originality
2/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper introduce a new method for the task of human mesh recovery in global coordinate system (world-grounded) from video inputs. Based on the existing work GVHMR, the authors proposed to factorized the network prediction into two separate stages (called “uncertainty-aware factorization”): The first stage with a deterministic regression module just focusing on recovering a stable torso-root anchor, and the second stage with a probabilistic flow-matching module then completes the remaining non-torso articulation. The insight is that it is unnecessary to allocate generative capability for less ambiguous body part (e.g. torso). This approach shows comparable results to current SOTA methods with more clear gains in scenarios with heavy occlusions.

Strengths and weaknesses

Strengths:

  • Insightful factorization of HMR uncertainty. The paper’s core idea—that torso/root variables and distal limb motions have different levels of ambiguity and may benefit from different modeling choices—is intuitive and well-motivated for video HMR under occlusion.
  • Coherent ambiguity-aware completion framework. The masked flow-matching formulation and geometry-aware completion objectives are well aligned with the proposed factorization, keeping stable anchor variables fixed while refining ambiguous non-torso and world-motion components.
  • Strong results under occlusion-heavy evaluation/scenarios. The proposed method achieve consistent improvements over existing methods on the 3DPW-XOCC benchmark quantitatively, and show qualitative examples suggesting its usefulness when there is heavy occlusions (with video results in supple.).

Weakness:

  • Missing critical ablation study: The paper claims that factorizing the problem into separate deterministic and probabilistic modeling is beneficial, but the ablation does not compare against a full probabilistic model or a full deterministic model to justify that claim. This is a major concern.
  • Weak advantage beyond closest baselines. The method heavily builds on GVHMR-style world-grounded HMR (especially stage 1), but its standard benchmark gains over GVHMR are marginal or with mixed signals; moreover, on Table 4 (Occlusion-specific evaluation) where the proposed method shows consistent gains, GVHMR is missing.
  • Higher runtime and memory cost. The proposed method is much more time consuming than GVHMR (“3.92 ± 0.03 seconds per sequence versus 0.41 ± 0.01 seconds”) while takes more memory (“1057.0 MB versus 303.6 MB”), making the added complexity difficult to justify especially when outside the occlusion-heavy cases.
Questions
  1. Can the authors provide controlled ablations against fully deterministic and/or fully probabilistic approach to better isolate the benefit of the proposed factorization?
  2. Can the authors include GVHMR results on 3DPW-XOCC benchmark (Table 4), since it is the closest baseline?
Limitations

Yes.

Final justification

Thanks authors for the detailed rebuttal and the additional experiments. The newly added controlled ablation substantially strengthens the central claim that the proposed deterministic/probabilistic factorization, rather than simply adopting a two-stage design, contributes to the performance gains. I also appreciate the additional GVHMR comparison on the XOCC benchmark and the clarification regarding the evaluation protocol.

I still think the novelty over the closest prior work and the efficiency trade-off should be presented more carefully, but the authors have acknowledged these limitations and appropriately narrowed their claims in the rebuttal. Overall, my main technical concerns have been sufficiently addressed, and I am updating my recommendation to Borderline Accept.

Formatting concerns

None

5 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We thank the reviewer for recognizing the core idea of the paper: torso/root variables and distal limb motions have different levels of ambiguity and may benefit from different modeling choices. Reviewer U2DP also recognized the decoupling as a reasonable and principled design choice, and Reviewer P753 noted that the per-joint and torso-region analyses support this factorization. We agree that the paper should better separate this central deterministic-probabilistic factorization from the supporting implementation details, and that the empirical claims should not overstate uniform gains over the closest deterministic video-HMR baselines.

Controlled deterministic/probabilistic ablation

We agree that a matched diagnostic can further clarify the design choice, and we appreciate that ov1a already recognizes the core idea: “torso/root variables and distal limb motions have different levels of ambiguity and may benefit from different modeling choices.” Our current Table 2 was intended to make this point concrete at the regional level: the torso region, estimated by deterministic Stage 1, improves over GVHMR across all three datasets; the non-torso region, generated by probabilistic Stage 2, improves MPJPE across all three datasets. As stated in the paper, this provides evidence that both estimation paradigms play a meaningful role in the model, rather than the method being only a generic two-stage architecture.

Variant 3DPW MPJPE ↓ 3DPW PA-MPJPE ↓ 3DPW PVE ↓
Deterministic Torso prediction / Deterministic Non-Torso prediction 60.2 40.7 74.0
Deterministic Single-stage with part-aware loss 58.4 37.8 70.6
Probabilistic Torso prediction / Probabilistic Non-Torso prediction 68.9 45.5 81.0
Probabilistic Single-stage with part-aware loss 59.8 39.5 74.1
Ours: Deterministic Torso prediction / Probabilistic Non-Torso prediction 56.2 36.9 68.3
Table 1. Controlled factorization and Stage~2 diagnostics

We also add a controlled ablation experiment in Table 1 to make this mechanism easier to inspect: here, we used a deterministic model for predicting the non-torso parameters (row1), and a probabilistic model for predicting the torso parameters (row3) When we experimented with using a single paradigm for both stages, the scores all degrade compared to the original one, supporting the interpretation that was given by Table 2: that the benefit is to assign different paradigms to variables of different characteristics. We will use this table to make the mechanism easier to inspect, while keeping the main claim scoped to deterministic--probabilistic factorization rather than broad “uncertainty modeling.”

Weak advantage beyond closest baselines

Standard HMR benchmarks such as 3DPW, RICH, and EMDB contain many well-observed frames where strong deterministic temporal regression is already highly effective. Moreover, even occlusion-oriented benchmarks such as 3DPW-XOCC still provide only one target pose per frame, so MPJPE/PA-MPJPE/PVE measure closeness to a single annotated answer rather than whether a method can represent multiple poses that may be visually plausible under occlusion or truncation. Because of this, current benchmark tables can only partially reflect the intended strength of FactorizedHMR; our method is designed for cases where the non-torso body regions (e.g., legs, arms) are occluded, with no visible "answer", and thus may benefit from probabilistic generation. This distinction is not fully captured when every frame is evaluated against one reference pose.

At the same time, these benchmarks remain useful for testing whether the method preserves accurate single-reference recovery. Under this evaluation setting, FactorizedHMR remains competitive with the strongest video-HMR baselines, while the region-wise analysis and controlled diagnostics provide more direct evidence for the deterministic--probabilistic decomposition. We will revise the paper to make this claim scope clearer and avoid suggesting that current single-answer benchmarks fully validate multi-plausible HMR. We also view this as motivation for future benchmarks that evaluate not only distance to one annotated pose, but also the plausibility and coverage of multiple valid reconstructions under incomplete visual evidence.

Runtime and memory cost

The reported 50-step result is a conservative/default sampling configuration and should not be read as the only practical operating point. And our goal is not to claim that FactorizedHMR is always the fastest choice, but to highlight a different direction for pose interpretation: keeping well-constrained variables deterministic while using probabilistic generation only where visual evidence is underconstrained. Reviewer P753 also pointed out that as in Figure~7, which we will move to the main paper, the supplementary ODE-step sweep already suggests a lower-step practical setting. We further report the runtime / memory analysis in Table 2, measured on an NVIDIA RTX A6000 for a sequence length of 1193, same as in the original paper:

Method / variant Total Latency (seconds) Steady Throughput (frames/sec) Peak GPU allocated memory (MB)
GVHMR 0.41 2708.41 303.6
Ours, recommended fast setting (20 steps, without CFG) 0.96 1248.05 651.9
Ours, conservative/default (50 steps, with CFG) 3.92 297.9 1057.0
Table 2: Runtime / Memory Analysis

As shown here, turning off classifier-free guidance and using 20 ODE steps instead of the conservative 50-step CFG setting substantially reduces latency and memory, moving the runtime much closer to GVHMR while preserving the intended probabilistic component. We will revise the paper to present the 20-step no-CFG setting as the recommended fast setting and to state that further investigation of sampling schedules, distillation, or adaptive-step inference may make the runtime and memory cost more comparable to deterministic baselines.

Question: GVHMR on 3DPW-XOCC

We will clarify that 3DPW-XOCC differs from the standard evaluations because there was not any reproducible implementation: the GVHMR/GENMO dataset cache, or any other open sourced code such as NIKI did not include imgfeats/3dpw_occ_test, which is required by the 3DPW-XOCC dataloader for bounding boxes, keypoints, and image features. Therefore, an exact reproduction was not possible from the released resources, and we reconstructed imgfeats/3dpw_occ_test following the published NIKI protocol:

The dataset is augmented from the original 3DPW dataset by adding temporally-smooth synthetic occlusions and truncations. To ensure temporal smoothness, we choose keyframes at an interval of 8 frames, and the rest frames are generated by linearly interpolating the clipping and occlusion of the keyframes. In the keyframe, the image is randomly clipped to ensure that at least one body part is outside the clipped image with a possibility of over 2/3. A square area that takes up to 30% of the clipped image is replaced by gaussian noise to serve as occlusion.

We also clarify that XOCC is a robustness stress test rather than the integral proof of our probabilistic hypothesis. It still has a single target pose per frame, so it cannot measure whether other generated poses are also plausible under the occluded evidence. Scoring well on XOCC therefore supports robustness to synthetic truncation/occlusion under single-reference metrics, but it does not by itself prove the multi-plausible-answer motivation that led us to use probabilistic generation. For this reason, we will avoid overclaiming from XOCC alone and will use it together with the regional Table 2 evidence and the controlled Stage 2 diagnostic. In the revision, we will either report all methods under a finalized reconstructed XOCC protocol, or clearly mark XOCC as a protocol-limited robustness analysis.

Authors · CommentOpenReview ↗

Thank you again for the careful review. We wanted to add a small update on this point during the discussion period.

As mentioned in our rebuttal, we could not find an exact public 3DPW-XOCC reproduction path because the released cache did not include imgfeats/3dpw_occ_test, so we reconstructed the feature cache following the NIKI 3DPW-XOCC protocol and evaluated the baselines under the same reconstructed setting. Under this protocol, we obtain:

Method PA-MPJPE ↓ MPJPE ↓ PVE ↓
GVHMR 54.2 93.2 110.4
GENMO (official implementation) 55.3 87.3 106.1
Ours 45.1 66.3 81.2

We do not want to overstate this result, since XOCC is still a single-target benchmark and this is a reconstructed protocol rather than an official released cache. We will state this clearly in the revision. We just wanted to provide this additional comparison since your review explicitly asked about GVHMR on XOCC.

If there are any remaining concerns or questions about the ablation, XOCC protocol, or claim scope, we would be happy to clarify further.

Authors · CommentOpenReview ↗

Thank you again for the careful review. Since the author-reviewer discussion period is closing soon, we wanted to check whether there are any remaining concerns that we can still clarify.

We appreciate the feedback, especially because your review directly identified the core ambiguity-based factorization we intended. We would be happy to answer any follow-up questions before the discussion period ends.

Reviewer U2DPOpenReview ↗
Rating
4/6
Confidence
2/5
Quality
3/4
Clarity
2/4
Significance
2/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper tackles the task of video-based Human Mesh Recovery (HMR), which aims to reconstruct 3D human meshes from video sequences. This task is highly challenging due to frequent self-occlusions, object occlusions, and inherent depth ambiguities. To address these issues, the authors observe that different body parts exhibit varying levels of estimation difficulty; specifically, the torso and root structures remain relatively stable, while the limbs (arms and legs) undergo rapid movements and are prone to severe occlusions. Based on this key observation, the paper proposes "FactorizedHMR," an uncertainty-aware factorization framework. This method decouples the video HMR task into two sequential stages: stable torso-root estimation (Stage 1) and the remaining non-torso articulation/motion completion (Stage 2). The proposed approach is evaluated on standard HMR benchmarks (3DPW, RICH, and EMDB-1), demonstrating improvements in handling occlusions and joint refinement.

Strengths and weaknesses

Strengths

The paper is well-motivated and clearly formulates the problem. The core observation—that estimation difficulty varies across body parts and thus warrants differentiated treatment—is intuitive and provides a logical foundation for the proposed two-stage design. The decoupling of stable structural estimation from ambiguity-prone motion completion is a reasonable and principled design choice. Furthermore, the supplementary video and the project webpage are helpful resources that support the understanding of the proposed approach and its qualitative results.

Weaknesses

This reviewer's primary concern is that it is difficult to clearly assess the advantages of the proposed approach over the strongest baseline methods, namely GENMO and GVHMR, for the following reasons.  

  1. Performance inconsistency with baseline papers.  The reported performances of certain baseline methods appear inconsistent with those reported in their original publications. For instance, GENMO, published at ICCV 2025, reports a PA-MPJPE of 34.6 (w/ 2D training) and 35.2 (w/o 2D training) on the 3DPW camera-space benchmark, whereas this paper reports GENMO's performance as 42.9. A similar discrepancy is also observed for GVHMR. While this reviewer acknowledges that such differences may stem from different evaluation protocols or experimental settings, this inconsistency is not explained in the paper, making it difficult to fairly interpret the comparison results. The authors should clarify whether these differences arise from, for example, different data splits, evaluation subsets, or pre-processing pipelines.

  2. Limited design choice justification for the two-stage framework.  This reviewer notes that the same core idea—differentiating between stable and unstable body parts—could potentially be implemented through alternative designs, such as introducing a part-aware loss function that assigns different constraints or weights to torso and non-torso joints within a single-stage framework. Such an approach could offer practical advantages including reduced inference cost and more flexible weight balancing between the two body part groups. Thus, this reviewer believes it would strengthen the paper if the authors could provide a clearer rationale for why the two-stage framework was chosen over alternative implementations of the same underlying idea, as this design choice appears to be central to the paper's contribution.

Questions
  1. As noted in the Weaknesses section, there appear to be notable discrepancies between the baseline performances reported in this paper and those in the original publications (e.g., GENMO: 42.9 vs. 34.6 PA-MPJPE on 3DPW). Could the authors clarify what experimental settings or evaluation protocols led to these differences? In particular, are the evaluations conducted under the same train/test splits and pre-processing conditions?

  2. The proposed two-stage design is built upon GVHMR, which was itself published relatively recently (2024). Could the authors elaborate on what specific limitations of GVHMR motivated the proposed two-stage factorization, and how the proposed approach differs from simply fine-tuning or extending GVHMR with an additional articulation completion module?

  3. As mentioned in the weaknesses, the core idea of decoupling torso and non-torso estimation could potentially be realized through a part-aware loss function within a single-stage framework, without the added complexity of a two-stage pipeline. What is the primary rationale for the two-stage design over such alternatives? Have the authors considered or experimented with such alternative implementations?

Limitations

yes

Final justification

Overall, my final recommendation is "Borderline." The rebuttal well addressed my original concerns regarding the reproduced baseline results and the motivation for the proposed two-stage framework. However, I remain uncertain whether the performance improvements are sufficient to justify the additional memory consumption and slower inference compared with recent strong baselines such as GVHMR. Since human motion reconstruction is not my primary area of expertise, I am not confident in judging the practical importance of this trade-off. Therefore, I leave the final decision to the AC and reviewers with deeper expertise in this subfield.

Formatting concerns

No formatting concerns

5 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We thank the reviewer for the constructive review and for recognizing that the motivation is well formulated, and that separating stable structural estimation from ambiguity-prone completion is a reasonable and principled design choice. Reviewer ov1a also describes the core idea very directly, and reviewer P753 also found the per-joint analysis and torso-region results useful.

Baseline performance discrepancies with original papers

Our intended protocol was to use public implementations and evaluate them under a common pipeline whenever possible. For GENMO (Repository link: https://github.com/NVlabs/GENMO), our comparison uses the official public GENMO release available during our experiments: the first released checkpoint (s050000.ckpt, released around Nov. 2025) and the official repository snapshot cloned in Feb.~2026. We attempted to reproduce the published GENMO numbers with that exact public codebase and checkpoint, but the reproduced metrics did not exactly match the values reported in the paper. This was not unique to our setup: similar mismatches were independently reported in the public GENMO repository issue “Unable to reproduce paper results” (Issue #11; https://github.com/NVlabs/GENMO/issues/11) and remained unresolved when we finalized our experiments. For this reason, we reported the results reproduced from the public GENMO implementation, rather than mixing them with paper-reported numbers that may depend on unreleased preprocessing, scripts, or checkpoints.

We also clarify that our comparison is against GENMO as publicly released at the time of our paper, not the later reorganized/re-released GEM version. After our experiments were completed and the paper was submitted to NeurIPS, the project appears to have been reorganized and re-open-sourced under the GEM name. To avoid ambiguity, we will explicitly state that the reported baseline corresponds to the GENMO checkpoint/repository snapshot used during our experiments (s050000.ckpt, Feb. 2026 repository snapshot), not to the latest GEM repository state. This distinction matters because paper-reported numbers may depend on a different release or evaluation path than the public GENMO checkpoint/code available at the time of our experiments.

For GVHMR (https://github.com/zju3dv/GVHMR), we used the official repository snapshot from Dec.~2025 and the official release checkpoint (gvhmr_siga24_release.ckpt). This implementation closely matched the paper-reported RICH results, while showing small deviations on 3DPW and EMDB. We believe these differences are likely due to frame preprocessing, dependency/version differences, filtering, or dataset conversion details, rather than a different model. We will document the repository snapshot, checkpoint name, evaluation script, preprocessing, and split/subset used for each reproduced baseline, so the reader can interpret our baseline table as a unified reproduction protocol rather than unexplained deviations from original papers.

Why two-stage factorization instead of a part-aware single-stage loss?

While a part-aware loss is a natural alternative, it addresses a different level of the problem. A weighted loss can emphasize difficult joints during training, yet at inference time it still treats the entire body as a deterministic output of one regressor. Our observation is not only that non-torso joints have higher error, but also that they have a different distribution, and thus the model should play different roles for different parts: the torso/root part should act as an anchor and derived deterministically, while the non-torso part should be generated conditionally around that anchor.

Variant 3DPW MPJPE ↓ 3DPW PA-MPJPE ↓ 3DPW PVE ↓
Deterministic Torso prediction / Deterministic Non-Torso prediction 60.2 40.7 74.0
Deterministic Single-stage with part-aware loss 58.4 37.8 70.6
Probabilistic Torso prediction / Probabilistic Non-Torso prediction 68.9 45.5 81.0
Probabilistic Single-stage with part-aware loss 59.8 39.5 74.1
Ours: Deterministic Torso prediction / Probabilistic Non-Torso prediction 56.2 36.9 68.3
Table 1. Controlled factorization and Stage~2 diagnostics

This distinction is also reflected in Table~1. As suggested by the reviewer, using a part-aware loss can improve over the naive same-paradigm settings, but they still do not match our factorized design. Also, making both torso and non-torso probabilistic performs much worse, which supports our point that the stable torso/root part should not be generated probabilistically. So the gain is not only from emphasizing non-torso joints through a specific loss term: it comes from assigning deterministic estimation to stable variables and probabilistic generation to ambiguous variables, which differentiates our structure from simple two-stage pipelines rooted from a GVHMR model.

Relationship to GVHMR and motivation for the added factorization

GVHMR is a strong deterministic world-grounded HMR foundation, and our method intentionally preserves the parts of that design that are stable. The limitation we target is the single deterministic treatment of all variables, including distal articulation and world-motion components that can be underconstrained by the image. FactorizedHMR changes this inference structure by estimating a deterministic torso/root anchor first and then generating ambiguity-prone variables conditionally. Our contribution is that, as also shown in Table~2, this variable-level reassignment of what should be anchored and what should be generated, rather than a generic second head on top of GVHMR.

We agree that the advantage should be presented as targeted rather than uniform. The point is not that GVHMR is weak, or that our method dominates every metric. The point is that GVHMR gives a strong deterministic foundation, and FactorizedHMR changes the inference structure only where the variables are more underconstrained. This is also why ov1a's comment on the “insightful factorization of HMR uncertainty” and different ambiguity levels is important to us: it matches exactly the design choice we want to make more explicit, and separates our method from being only another augmentation over GVHMR. We will revise the paper to emphasize this targeted advantage instead of overclaiming broad superiority over GVHMR/GENMO.

Authors · CommentOpenReview ↗

Thank you again for the constructive review. We have tried to address the main concerns you raised, especially the reproduction protocol ("Performance inconsistency with baseline papers") and the comparison with a part-aware single-stage alternative. ("Limited design choice justification for the two-stage framework. "). We are happy to clarify any remaining questions during the discussion period, particularly if any part of our rebuttal remains unclear.

Authors · CommentOpenReview ↗

Thank you again for the constructive review. Since the discussion period is closing soon, we wanted to check whether there are any other remaining questions that we can still clarify.

We appreciate the feedback, and would be happy to clarify anything that is still unclear before the discussion period ends.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.