Abstract. Physical control systems, such as building HVAC systems, thermal processes, and power-grid assets, often involve delayed dynamics, safety constraints, and costly online interaction. Because the effect of a control action may appear after several time steps, effective control often requires reasoning over histories of states, actions, and outcomes. Pretrained sequence controllers, such as Decision Transformers, provide a natural way to model this history-dependent control problem by learning policies from offline trajectories, reducing the need for expensive online retraining. However, their performance can degrade when deployment conditions differ from the training data. In building control, for example, actuator wear, sensor drift, occupancy changes, and weather variation can all affect the observed response of the system to the same control action. Online adaptation is therefore needed, but raw prediction error is not always a reliable signal for updating the controller. The key challenge is to identify which part of the observed mismatch is action-sensitive and should guide policy adaptation. To address this challenge, we propose DARPAN, a Drift-Aware Residual Policy Adapter Network for pretrained physical control. DARPAN keeps the pretrained Decision Transformer frozen and performs online adaptation only through lightweight residual adapters, preserving the offline policy and limiting the number of trainable parameters. Instead of updating from raw prediction error, DARPAN uses a controllability filter trained in simulation to extract the action-sensitive part of the residual and filter out mismatch that is weakly related to the controller's actions. During deployment, a frozen predictor estimates the next state, the controllability filter produces a filtered residual, and a short history of filtered residuals forms a drift signature. This signature is used to select an existing adapter or create a new one when a persistent drift pattern appears. We benchmark DARPAN on SustainGym under actuator faults, sensor drift, delays, and external disturbances. In the building control environment (BuildingEnv), DARPAN reduces drift-induced performance loss by 31.7±1.1%31.7 \pm 1.1\% and uses 63%63\% fewer online parameters than Online-head DT. We release our code and experiment configurations at https://huggingface.co/ananypratap007/DARPAN2026.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
24 Apr 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:45 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

Summary: The paper proposes DARPAN, a framework for online adaptation of pretrained Decision Transformer controllers in physical control systems (building HVAC, cogeneration) subject to deployment-time drifts, e.g., actuator faults, sensor bias, delays, weather variation. They claim that adaptation should respond only to the action-sensitive portion of prediction error, i.e., residuals caused by controllable factors, while ignoring residuals from uncontrollable external disturbances. To this end, DARPAN freezes the pretrained backbone and uses a controllability filter (trained offline via counterfactual simulation) to score and mask prediction residuals. To validate their framework, the authors use the SustainGym's BuildingEnv and CogenEnv platforms. The evaluation under a 60-day rotating fault protocol reports recovery of 31.7% of drift-induced performance loss with substantially fewer online parameters than baselines. The ablation study demonstrates that each component (filter, history, expansion rule, adapter specialization) addresses a distinct failure mode.

Main strengths:

  1. Online adaptation should be selective to distinguish controllable from uncontrollable residuals is principled and underexplored. The connection to matched vs. unmatched disturbances in classical control theory is apt.

  2. Each component (frozen backbone, controllability filter, drift signature, adapter library) has a clearly defined role. The ablation study in Table 3 shows qualitatively distinct failure modes when each component is removed, providing genuine design validation.

  3. Adapter sizes (142 and 496 parameters) are extremely small compared to the pretrained backbone, making deployment on edge hardware plausible.

  4. The 60-day rotating drift schedule with mixed and compound faults is more realistic than single-perturbation evaluations, and SustainGym is a credible domain benchmark.

Main weaknesses

  1. Some critical hyperparameters are undisclosed based on Reviewers m4CW and qw9L. The filter threshold, history length, corrective strength, regularization weight, adapter MLP architecture, cosine similarity threshold, and persistence step count are all named but never assigned numerical values. Appendix F.5 discusses them qualitatively ("if too low... if too high") without giving the actual values. This fundamentally blocks reproducibility.

  2. For CogenEnv, the controllability filter is trained on labeled fault trajectories from the same catalog used in evaluation (Table 9). The strong results (e.g., 96% reduction in false creations) may reflect in-distribution pattern recognition rather than a general ability to separate controllable from external residuals. No held-out fault evaluation is provided.

  3. For a "use-inspired" contribution, the paper does not compare against standard robust/adaptive control strategies (disturbance-observer-based controllers, robust MPC, gain-scheduled controllers) that are widely used in HVAC and power systems and are also motivated by separating controllable and exogenous effects.

  4. Based on Reviewer m4CW, there are ambiguous and potentially misleading parameter claim. E.g, the abstract states "63 percent fewer online parameters than an 'Online DT' baseline." This figure only holds when comparing DARPAN's BuildingEnv parameters (142) to Online-Head DT's BuildingEnv parameters (390). Compared to Full Online DT (387,503 params), the reduction is 99.96%. The abstract's wording is unqualified and environment-specific. It is also not clarified whether the frozen short-horizon predictor f^\hat{f} is the DT's own 1-step state head or a separately trained model. Online PPO and Full Online DT show negative recovery (worsening performance). This may reflect undertuning (e.g., inappropriate learning rates) rather than inherent limitations of online adaptation. No hyperparameter search details are provided.

  5. The evaluation is purely simulation-based, with no real-world data, practitioner engagement, or case study on in-the-field constraints. The building evaluation uses a single configuration (OfficeSmall), so generalizability across buildings, climates, or demand patterns is not established.

  6. Symbol rr is overloaded for both reward and residual; false creation counts differ between Tables 2 and 3; the "Recovery change" metric is undefined for disturbance-only phases; and the adapter creation rule is qualitatively described ("persists for several steps") without quantification.

Weaknesses that need to be addressed in addition to the above:

  1. The authors must disclose numerical values for cfilter,α,H,λc_\text{filter}, \alpha, H, \lambda, cosine similarity threshold, persistence criterion, and adapter MLP architectures for both environments. Without this, the method is not reproducible.

  2. The authors should evaluate the controllability filter on at least one drift type not represented in the training catalog (e.g., train the CogenEnv filter without wind shift faults and test on a wind shift segment). A positive result showing that the filter generalizes beyond its training distribution would substantially reduce concerns about in-distribution pattern matching.

  3. Reporting recovery separately for each fault segment (weak actuator, sensor bias, delay, stuck actuator, compound) would reveal where the remaining 68% performance gap originates. This would also clarify whether the predictor mismatch under delay is a critical limitation.

  4. The authors should also clarify the 63% claim in the abstract, reconcile the Table 2/3 false creation discrepancy, and provide baseline tuning details for Online PPO and Full Online DT to demonstrate that negative recovery is not due to undertuning, the paper could become more technically solid and sound.

Final justification

After careful consideration of the initial reviews, the authors' rebuttal, and the subsequent reviewer discussions, I think the reviewers were satisfied with the rebuttals and how the authors addressed their comments. Particularly, they have provided the specified hyperparameters and addressed the controllability filter. The quality of this paper has been improved. I think it reaches the acceptance bar.

Area Chair pUQw · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

Summary: The paper proposes DARPAN, a framework for online adaptation of pretrained Decision Transformer controllers in physical control systems (building HVAC, cogeneration) subject to deployment-time drifts, e.g., actuator faults, sensor bias, delays, weather variation. They claim that adaptation should respond only to the action-sensitive portion of prediction error, i.e., residuals caused by controllable factors, while ignoring residuals from uncontrollable external disturbances. To this end, DARPAN freezes the pretrained backbone and uses a controllability filter (trained offline via counterfactual simulation) to score and mask prediction residuals. To validate their framework, the authors use the SustainGym's BuildingEnv and CogenEnv platforms. The evaluation under a 60-day rotating fault protocol reports recovery of 31.7% of drift-induced performance loss with substantially fewer online parameters than baselines. The ablation study demonstrates that each component (filter, history, expansion rule, adapter specialization) addresses a distinct failure mode.

Main strengths:

  1. Online adaptation should be selective to distinguish controllable from uncontrollable residuals is principled and underexplored. The connection to matched vs. unmatched disturbances in classical control theory is apt.

  2. Each component (frozen backbone, controllability filter, drift signature, adapter library) has a clearly defined role. The ablation study in Table 3 shows qualitatively distinct failure modes when each component is removed, providing genuine design validation.

  3. Adapter sizes (142 and 496 parameters) are extremely small compared to the pretrained backbone, making deployment on edge hardware plausible.

  4. The 60-day rotating drift schedule with mixed and compound faults is more realistic than single-perturbation evaluations, and SustainGym is a credible domain benchmark.

Main weaknesses

  1. Some critical hyperparameters are undisclosed based on Reviewers m4CW and qw9L. The filter threshold, history length, corrective strength, regularization weight, adapter MLP architecture, cosine similarity threshold, and persistence step count are all named but never assigned numerical values. Appendix F.5 discusses them qualitatively ("if too low... if too high") without giving the actual values. This fundamentally blocks reproducibility.

  2. For CogenEnv, the controllability filter is trained on labeled fault trajectories from the same catalog used in evaluation (Table 9). The strong results (e.g., 96% reduction in false creations) may reflect in-distribution pattern recognition rather than a general ability to separate controllable from external residuals. No held-out fault evaluation is provided.

  3. For a "use-inspired" contribution, the paper does not compare against standard robust/adaptive control strategies (disturbance-observer-based controllers, robust MPC, gain-scheduled controllers) that are widely used in HVAC and power systems and are also motivated by separating controllable and exogenous effects.

  4. Based on Reviewer m4CW, there are ambiguous and potentially misleading parameter claim. E.g, the abstract states "63 percent fewer online parameters than an 'Online DT' baseline." This figure only holds when comparing DARPAN's BuildingEnv parameters (142) to Online-Head DT's BuildingEnv parameters (390). Compared to Full Online DT (387,503 params), the reduction is 99.96%. The abstract's wording is unqualified and environment-specific. It is also not clarified whether the frozen short-horizon predictor f^\hat{f} is the DT's own 1-step state head or a separately trained model. Online PPO and Full Online DT show negative recovery (worsening performance). This may reflect undertuning (e.g., inappropriate learning rates) rather than inherent limitations of online adaptation. No hyperparameter search details are provided.

  5. The evaluation is purely simulation-based, with no real-world data, practitioner engagement, or case study on in-the-field constraints. The building evaluation uses a single configuration (OfficeSmall), so generalizability across buildings, climates, or demand patterns is not established.

  6. Symbol rr is overloaded for both reward and residual; false creation counts differ between Tables 2 and 3; the "Recovery change" metric is undefined for disturbance-only phases; and the adapter creation rule is qualitatively described ("persists for several steps") without quantification.

Weaknesses that need to be addressed in addition to the above:

  1. The authors must disclose numerical values for cfilter,α,H,λc_\text{filter}, \alpha, H, \lambda, cosine similarity threshold, persistence criterion, and adapter MLP architectures for both environments. Without this, the method is not reproducible.

  2. The authors should evaluate the controllability filter on at least one drift type not represented in the training catalog (e.g., train the CogenEnv filter without wind shift faults and test on a wind shift segment). A positive result showing that the filter generalizes beyond its training distribution would substantially reduce concerns about in-distribution pattern matching.

  3. Reporting recovery separately for each fault segment (weak actuator, sensor bias, delay, stuck actuator, compound) would reveal where the remaining 68% performance gap originates. This would also clarify whether the predictor mismatch under delay is a critical limitation.

  4. The authors should also clarify the 63% claim in the abstract, reconcile the Table 2/3 false creation discrepancy, and provide baseline tuning details for Online PPO and Full Online DT to demonstrate that negative recovery is not due to undertuning, the paper could become more technically solid and sound.

Final justification

After careful consideration of the initial reviews, the authors' rebuttal, and the subsequent reviewer discussions, I think the reviewers were satisfied with the rebuttals and how the authors addressed their comments. Particularly, they have provided the specified hyperparameters and addressed the controllability filter. The quality of this paper has been improved. I think it reaches the acceptance bar.

3 comments
Authors · CommentOpenReview ↗

We thank the Area Chair for the careful summary and for identifying the issues most important to the decision. To avoid duplicating the full reviewer responses, we summarize the corresponding clarifications, new analyses, and planned corrections below.

1. Reproducibility and deployment hyperparameters

We agree that the deployment settings should have been stated explicitly. We now provide all values for both environments. The signature history is H=12H=12, the filter threshold is cfilter=0.50c_{\mathrm{filter}}=0.50, the cosine-similarity threshold is τ=0.91\tau=0.91, and a new adapter is created after Kcreate=24K_{\mathrm{create}}=24 consecutive novel signatures. We use corrective strength α=0.8\alpha=0.8, correction penalty λ=10−3\lambda=10^{-3}, and library capacity Mmax⁡=40M_{\max}=40.

Each adapter is a one-hidden-layer MLP, Linear(dx,8)→ReLU→Linear(8,du)\mathrm{Linear}(d_x,8)\rightarrow\mathrm{ReLU}\rightarrow\mathrm{Linear}(8,d_u), with (dx,du)=(10,6)(d_x,d_u)=(10,6) for BuildingEnv and (44,15)(44,15) for CogenEnv. This yields 142 and 495 online parameters, respectively. We will add the complete table to the revised appendix and shared code. Full details are provided in our response to m4CW Q1.

2. Held-out CogenEnv filter evaluation

We clarify that the catalog-supervision concern applies specifically to CogenEnv. BuildingEnv trains the filter from simulator counterfactuals generated by varying actions and external conditions, without observing fault identities or using the evaluation fault catalog. CogenEnv uses fault-to-dimension supervision because its ONNX interface does not provide the same counterfactual reset capability.

Following the suggested test, we are planning on conducting that experiment and retraining the CogenEnv filter after removing trajectories containing the wind-shift component and will evaluate it on the held-out wind-shift segments. We will compare recovery and false-adapter creations against the full-catalog filter and report the corresponding segment-level CogenEnv results. This directly tests whether the filter generalizes beyond residual patterns represented in its training catalog. Full details are provided in our response to m4CW Q2. We will update the results in the comments once the experiment is complete.

3. Source of the remaining recovery gap

We computed BuildingEnv recovery separately for each fault segment across five runs. Recovery under weak actuation decreases with severity from 48.5±1.6%48.5\pm1.6\% to 28.0±1.7%28.0\pm1.7\% and 11.3±2.0%11.3\pm2.0\%. Recovery is lower for stuck actuators at 8.9±2.1%8.9\pm2.1\% and 3.1±1.4%3.1\pm1.4\%, while sensor-bias segments achieve 37.4±1.1%37.4\pm1.1\%, 41.9±4.4%41.9\pm4.4\%, and 48.2±1.1%48.2\pm1.1\%. Compound-fault recovery is 31.3±2.4%31.3\pm2.4\%, and short- and long-delay recovery are 63.3±1.3%63.3\pm1.3\% and 40.4±14.9%40.4\pm14.9\%.

These results show that the remaining gap is not uniform. It is largest when actuator degradation physically restricts the available heating or cooling capacity, while sensor bias and shorter delay remain more recoverable. We provide the complete interpretation and delay diagnostic in our responses to m4CW Q3 and Q4. The corresponding CogenEnv segment-level values will be reported with the held-out-filter evaluation.

4. Parameter claim, predictor identity, and baseline interpretation

The reported 63% reduction refers specifically to BuildingEnv relative to Online-Head DT, where DARPAN updates 142 parameters rather than 390, corresponding to 63.6% fewer online parameters. We will qualify the environment and baseline explicitly in the abstract. Relative to Full Online DT, which updates 387,503 parameters, the reduction is 99.96%.

The deployment predictor is a separately trained, action-conditioned one-step dynamics model. It is not the Decision Transformer’s auxiliary state-prediction head, and we will clarify this in Section 3.

For the negative-recovery baselines, we report the exact tested configurations and interpret the results only within the common deployment budget. BuildingEnv provides 17,280 interactions over 60 days, with each drift segment lasting five days; CogenEnv provides 1,344 interactions over 14 days, with most fault conditions lasting one day. Full Online DT was also extended to 180 days and reached approximately 10% recovery, showing that it can improve with additional interaction but remains substantially slower than DARPAN’s 31.7%31.7\% recovery within the original protocol. We therefore do not claim that these baselines cannot eventually learn, only that they do not recover effectively within the evaluated deployment budget. Full details are provided in our responses to m4CW Q5-Q7.

Authors · CommentOpenReview ↗

5. Relationship to classical control

We agree that robust MPC, disturbance-observer-based control, and gain-scheduled control are important related approaches. The present evaluation asks a narrower controlled question: given the same pretrained Decision Transformer, which online adaptation mechanism best handles deployment drift while preserving the pretrained backbone? The learning-based baselines therefore share the same controller initialization and deployment data.

A fair comparison with classical controllers would require environment-specific models, estimators, constraints, and tuning rather than changing only the adaptation mechanism. We will expand the discussion of this relationship and cite established robust and adaptive control approaches, while identifying a direct domain-specific comparison as important future work.

6. Consistency corrections and evaluation scope

We will rename the vector-valued prediction residual as et+1e_{t+1} while retaining rtr_t for reward and RtR_t for return-to-go. The false-creation values in Tables 2 and 3 came from separate seed sets; we will consolidate both tables using the same run set. During disturbance-only phases, we use the unnormalized penalty difference

ΔPdist=Pfrozen−Pmethod\Delta P_{\mathrm{dist}} = P_{\mathrm{frozen}}-P_{\mathrm{method}}

where positive values indicate a lower penalty than the frozen controller. We will define this separately from normalized Recovery in the table caption and state the adapter-creation rule quantitatively.

Finally, we agree that the current evidence is simulation-based and that OfficeSmall does not establish transfer across building architectures, climates, or physical deployments. We will state this scope more clearly. The current contribution is a controlled evaluation of selective deployment-time adaptation within a fixed pretrained system; real-building deployment, practitioner workflows, safety constraints, and evaluation across additional configurations remain important next steps.

Authors · CommentOpenReview ↗

Updates on Held-out CogenEnv filter evaluation: We wanted to update on the experiment regarding held-out filter training. We expanded the leave-one-mechanism-out evaluation beyond the suggested wind-shift experiment to four distinct mechanism families, covering wind shift, sensor drift, GT1 degradation, and multi-turbine degradation. For each condition, we retrained the controllability filter from scratch after removing every filter-training trajectory containing the held-out mechanism, including all compound trajectories in which that mechanism appeared. The evaluated mechanism was completely absent from the filter-training data.

The filter is not given a fault identity or fault class. It computes a per-dimension controllability score directly from the current state, the applied base action, and the resulting prediction residual:

pt+1=C(xt,atbase,rt+1),rt+1=xt+1−F(xt,atbase)p_{t+1} = C\left(x_t, a_t^{\mathrm{base}}, r_{t+1}\right), \qquad r_{t+1} = x_{t+1} - F\left(x_t, a_t^{\mathrm{base}}\right)

The results below show that exact exposure to the evaluated mechanism is not required, we will add this analysis to the revised manuscript.


Table: Leave-one-mechanism-out evaluation of the CogenEnv controllability filter. False adaptation rate is reported for exogenous segment that trigger an adapter update. Recovery is reported for controllable or compound segments.

Held-out mechanism Evaluation segment Metric Full catalog Held out
Wind shift F5 False adaptation rate (%) 1.3 ± 0.5 3.4 ± 0.6
Wind shift F7 Recovery (%) 48.5 ± 3.4 46.9 ± 6.8
Sensor drift F3/F4 False adaptation rate (%) 2.6 ± 0.2 4.9 ± 0.3
Sensor drift F8 Recovery (%) 46.0 ± 2.7 44.3 ± 3.2
GT1 degradation F1 segments Recovery (%) 43.6 ± 3.3 46.1 ± 3.1
Multi-turbine degradation F2 Recovery (%) 34.8 ± 2.3 34.2 ± 4.9
Active-fault aggregate Controllable/compound segments Recovery (%) 38.4 ± 1.8 37.2 ± 3.9

Aggregation note. The final row reports penalty-gap-weighted recovery only over controllable and compound fault segments. The 28.5% result in Table 1 is computed from the full 14-day rollout. It also includes clean and exogenous segments, so it is lower than the active-fault result and is not an average of the segment-level percentages.


Holding out wind shift increased false adaptation on F5 from 1.3% to 3.4%, while holding out sensor drift increased it on F3/F4 from 2.6% to 4.9%. Even without these mechanisms in training, 96.6% and 95.1% of timesteps did not trigger an adapter update. Compound-fault recovery changed only slightly. F7 changed from 48.5% to 46.9%, and F8 changed from 46.0% to 44.3%. Recovery also remained stable for held-out controllable faults. GT1 degradation changed from 43.6% to 46.1%, and multi-turbine degradation changed from 34.8% to 34.2%. Overall active-fault recovery changed from 38.4% to 37.2%.

Coming to per fault recovery for Cogen, DARPAN achieves 42.3% recovery on mild GT1 degradation, 38.0% on severe GT1 degradation, 22.7% on HRSG fuel-response degradation, and 34.8% on multi-turbine degradation. Recovery remains strong on the compound F7 and F8 faults at 48.5% and 46.0%, respectively.The final recurring GT1 segment reaches 57.8%, consistent with reuse of an earlier adapter.

Reviewer R588OpenReview ↗
Rating
4/6
Confidence
5/5
Quality
3/4
Clarity
4/4
Significance
3/4
Originality
3/4
Contribution type
use_inspired
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The paper proposes DARPAN, a Drift-Aware Residual Policy Adapter Network designed to adapt pretrained Decision Transformer controllers to deployment-time drift in physical control systems such as building HVAC and combined heat-and-power dispatch. The core idea is to keep the pretrained Decision Transformer and a short-horizon predictor frozen, and adapt only through small residual adapters that are selected and updated based on a drift signature. The method is evaluated in SustainGym’s BuildingEnv (HVAC comfort control) and CogenEnv (combined-cycle gas plant dispatch) under a carefully designed set of actuator faults, delays, sensor drift, external disturbances, and compound faults, showing improved recovery from drift with substantially fewer online trainable parameters than several online fine-tuning and adapter baselines.

Strengths and weaknesses

Quality: The problem is both well-chosen and clearly motivated: building climate control and power-plant dispatch are central to sustainable energy systems, and the paper articulates why offline-pretrained controllers face deployment drift and why naive online adaptation can be unsafe or inefficient in slow physical systems. The architecture is conceptually clean: a frozen Decision Transformer backbone provides base actions, a frozen predictor estimates the next state, a controllability filter extracts action-sensitive residual components, and a residual-adapter library uses temporal drift signatures to select or create small correction modules that are trained online via masked prediction-loss objectives. Empirically, the work is quite strong within its simulation scope. In both BuildingEnv and CogenEnv, DARPAN achieves the highest “recovery” (fraction of the performance gap between frozen and clean reference controllers that is closed) while updating the fewest online parameters, improving building comfort penalty by around 31.7% with only 142 online parameters and outperforming full online DT, online-head DT, LoRA-DT, Hyper-DT, and PPO baselines.

Clarity: The paper provides intuitive narrative of why raw residuals are problematic, how the controllability filter is trained (via simulator interventions or labeled fault trajectories), and how temporal averaging and adapter selection work, while the appendices provide detailed environment descriptions, data-collection protocols, model architectures, optimization settings, and the drift schedules. The mathematical definitions are precise, and the figures (especially the pipeline diagrams and the continual-drift plot with adapter index trace) help make the method’s behavior easy to follow.

Significance: DARPAN provides a principled mechanism to focus adaptation on controllable residuals and to reuse corrections over recurring drift patterns, and it clearly outperforms a range of strong transformer-based and RL baselines in two realistic simulation benchmarks.

Originality: The work combines several topics like Decision Transformers for offline control, residual policy learning, parameter-efficient adaptation, and controllable-factor representation learning. But the particular way they are fused here is, to my knowledge, novel.

While the set of learning-based baselines is broad (frozen DT, full online DT, online-head DT, LoRA-DT, Hyper-DT, and PPO), the paper does not include comparisons to more classical robust/adaptive control strategies (eg disturbance-observer-based controllers, robust MPC, or gain-scheduled controllers) that are widely used in HVAC and power systems and are also motivated by separating controllable and exogenous effects. For a use-inspired contribution, it would be valuable to see where DARPAN stands relative to such baselines, especially in terms of safety and interpretability.

Questions

It would help to have a more explicit discussion (or experiment) on the engineering overhead versus simpler schemes such as robust pretraining with broader fault-domain randomization or straightforward online-head adaptation with carefully tuned regularization.

Could you add an experiment where the filter is intentionally perturbed (e.g., trained on a mismatched simulator, corrupted labels, or systematically biased mask) to quantify how sensitive performance and false-adaptation behavior are to filter quality, and to show whether the method degrades gracefully as the filter becomes less accurate? A clear demonstration of robustness (or a failure mode) here would increase my confidence in deploying this in less controlled settings and could raise my quality and significance scores.

Limitations

The paper’s main limitations are also tightly tied to its use-inspired nature. First, the entire evaluation is based on simulators (SustainGym building and CogenEnv ONNX plant), and while these are realistic and open environments, there is no real-world data, no engagement with practitioners, and no case study tying the results directly to in-the-field constraints such as commissioning processes, safety envelopes, or maintenance workflows

DARPAN critically depends on an offline-trained controllability filter whose labels come from either simulator counterfactuals or a curated fault catalog; in many physical systems, such data may be expensive or unavailable, and the paper does not empirically analyze how performance degrades when the filter is mis-specified or trained under mismatch between simulator and deployment.

The building evaluation is performed on a single fixed configuration (OfficeSmall) and a limited set of drift types; there are no experiments across buildings with different numbers of zones, climates, or demand patterns, so the generality of the approach across the broader AI-for-sustainability space is more argued than demonstrated. In other words, scalability of generalizability of the approach is missing

Final justification

I am mostly satisfied with the rebuttal from the authors and given the acknowledgement of the limitations and some missing experiments that were vital to evaluate filter, I am maintaining my current rating.

Formatting concerns

None

2 comments
Authors · CommentOpenReview ↗

We thank the reviewer for the constructive feedback for recognizing the value of selective adaptation and parameter efficiency. The questions on engineering overhead and robustness to filter quality help us position the practical contribution more clearly and identify the most important next evaluation.


Q1. It would help to have a more explicit discussion (or experiment) on the engineering overhead versus simpler schemes such as robust pretraining with broader fault-domain randomization or straightforward online-head adaptation with carefully tuned regularization.

The frozen controller already receives broad pretraining the BuildingEnv data include varied operating conditions and fault-wrapped trajectories from the same broad fault families used in evaluation. DARPAN's gains therefore do not arise simply from comparing against a narrowly pretrained controller.

The distinction is that pretraining determines what the controller knows before deployment, whereas DARPAN determines what it should learn from after deployment. A fixed pretrained policy cannot incorporate a new correction from deployment data, and a generic online update does not distinguish correctable error from external variation. DARPAN adds selective learning from action-sensitive residuals and stores separate corrections for reuse when drift returns.

We compare directly with the simpler Online-Head DT under the same pretrained backbone and deployment data. In BuildingEnv, DARPAN achieves 31.7±1.1%31.7 \pm 1.1\% recovery with 142 online parameters, compared with 20.1±2.4%20.1 \pm 2.4\% using 390 parameters for Online-Head DT. Replacing the adapter library with one global adapter further reduces recovery to 8.4±1.5%8.4 \pm 1.5\%. Thus, the additional components provide selective adaptation and memory, rather than simply adding model capacity.


Q2 Could you add an experiment where the filter is intentionally perturbed (e.g., trained on a mismatched simulator, corrupted labels, or systematically biased mask) to quantify how sensitive performance and false-adaptation behavior are to filter quality, and to show whether the method degrades gracefully as the filter becomes less accurate?

This is a valuable suggestion, however, a multi-level study would require retraining the filter under several levels of label corruption or simulator mismatch and rerunning the full deployment protocol for each level. We cannot complete this study reliably within the rebuttal period, but we will state this limitation clearly and identify graded filter-quality sensitivity analysis as important future work.

Our existing no-filter ablation provides an informative extreme boundary case. Replacing the learned mask with an all-ones mask reduces recovery to 20.3±3.420.3 \pm 3.4% and increases false adapter creations from 1.20±0.451.20 \pm 0.45 to 30.60±5.5930.60 \pm 5.59. Thus, removing filter selectivity substantially reduces recovery and causes unnecessary library growth, while the remaining components still retain positive recovery. This ablation does not establish how performance changes under gradual filter corruption, and we will state that distinction clearly and include controlled filter-quality sensitivity as an important extension.

Authors · CommentOpenReview ↗

Limitations

1. Simulation-only evaluation

We agree that simulation-only evaluation is an important limitation. We view the present study as a controlled evaluation of selective deployment-time adaptation rather than a complete real-world control pipeline. Using BuildingEnv and CogenEnv allows us to introduce controllable faults, recurring drift, and exogenous disturbances reproducibly and to isolate the contribution of each adaptation component.

But we want to mention that these challenges are widely recognized in learning-based building control, where limited interaction data, occupant impact during learning, robustness, and building-specific deployment remain major barriers [1, 2]. Related work has demonstrated learning-based control on a physical data-center cooling system, but also highlights the additional care required for safe operation under limited data and unexpected events [3]. We will therefore make the present scope explicit and identify real-building evaluation, practitioner involvement, safety constraints, and comparison with established building-control approaches [4] as the next stage of this work.

2. Dependence on offline filter supervision

We would clarify that DARPAN does not necessarily require a curated catalog of fault identities. In BuildingEnv, the filter is trained automatically from simulator counterfactuals by varying actions and external conditions, without observing the evaluation fault labels. CogenEnv uses a fault-to-state-dimension mapping because its ONNX interface does not provide the same counterfactual reset capability.

Public HVAC resources containing labeled faulted and fault-free operation from simulation, laboratory facilities, and measurements provide a concrete basis for studying data-driven filter supervision beyond a simulator catalog [5]. These resources do not remove the data requirement, but they provide a practical path toward training and evaluating controllability estimates from measured system trajectories. We are aware of these data availability and therefore we are confident that DARPAN can be useful in such scenarios.

3. Single building configuration and architectural generality

The present scope is temporal adaptation of a fixed pretrained controller after deployment, rather than architectural transfer between systems. DARPAN is directly applicable to larger pretrained controllers, where its lightweight adapters can provide deployment-time corrections without updating the full backbone. Large-scale resources support pretraining and transfer studies across diverse building conditions. HOT provides approximately 150,000 building-weather configurations specifically for HVAC control-transfer research [6], BuildingsBench provides 900,000 simulated buildings for studying large-scale pretraining and transfer in building energy forecasting [7]. Pretrained sequence controllers have also begun to demonstrate transfer between simulated HVAC systems without updating their main network parameters [8].


References:

[1] Zhe Wang and Tianzhen Hong. Reinforcement learning for building controls: The opportunities and challenges. Applied Energy, 269:115036, 2020.

[2] Zoltan Nagy et al. Ten questions concerning reinforcement learning for building energy management. Building and Environment, 241:110435, 2023.

[3] Nevena Lazic, Craig Boutilier, Tyler Lu, Eehern Wong, Binz Roy, M. K. Ryu, and Greg Imwalle. Data center cooling using model-predictive control. In Advances in Neural Information Processing Systems, volume 31, pages 3818–3827, 2018.

[4] Ján Drgoňa, Javier Arroyo, Iago Cupeiro Figueroa, David H. Blum, Krzysztof Arendt, Donghun Kim, Enric Perarnau Ollé, Juraj Oravec, Michael Wetter, Draguna L. Vrabie, and Lieve Helsen. All you need to know about model predictive control for buildings. Annual Reviews in Control, 50:190–232, 2020.

[5] Jessica Granderson, Guanjing Lin, Yimin Chen, Armando Casillas, Jin Wen, Zhelun Chen, Piljae Im, Sen Huang, and Jiazhen Ling. A labeled dataset for building HVAC systems operating in faulted and fault-free states. Scientific Data, 10:342, 2023.

[6] Anaïs Berkes, Yoshua Bengio, David Rolnick, and Donna Vakalis. A HOT Dataset: 150,000 Buildings for HVAC Operations Transfer Research. In Proceedings of the 12th ACM International Conference on Systems for Energy-Efficient Buildings, Cities, and Transportation, pages 171–180, 2025.

[7] Patrick Emami, Abhijeet Sahu, and Peter Graf. BuildingsBench: A Large-Scale Dataset of 900K Buildings and Benchmark for Short-Term Load Forecasting. In Advances in Neural Information Processing Systems, volume 36, pages 19823–19857, 2023.

[8] Anaïs Berkes. HVAC-DPT: A Decision Pretrained Transformer for HVAC Control. arXiv preprint arXiv:2411.19746, 2024.

Reviewer qw9LOpenReview ↗
Rating
4/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
2/4
Originality
2/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper presents DARPAN, a framework for online adaptation of pre-trained physics-based controllers during deployment under system drift. At its core, rather than learning from all prediction errors indiscriminately, DARPAN first extracts residuals tied to actual control actions via a controllability-aware filter, then constructs temporal signatures from these filtered residuals, and finally selects or instantiates lightweight adapters to correct the frozen Decision Transformer.

Strengths and weaknesses

Strengths:

  1. The paper correctly identifies that raw prediction residuals are mixed signals, and DARPAN's core design precisely isolates the "action-controllable" portion, an approach well-aligned with deployment drift challenges in HVAC, thermal processes, and cogeneration scheduling.
  2. Experiments were designed to directly validate the paper's key claims across control performance, parameter efficiency, false adaptation under disturbances, and adapter reuse under continuous drift, establishing a clear mapping between experiments and method contributions.
  3. The parameter efficiency results are quite strong. Compared with full online DT, Online-head DT, LoRA-DT, and Hyper-DT, DARPAN achieves higher recovery with fewer online parameters in both BuildingEnv and CoGenEnv. This trade-off is very attractive.
  4. The ablation experiments in this paper have demonstrated the effectiveness of the design. When the filter, time signature, conservative library expansion strategy or adapter library are removed, they respectively show an increase in false creations, a decrease in reuse, library expansion or a decrease in recovery, indicating that the paper does not rely solely on the accumulation of benefits from a single component.

Weakness:

  1. The core gain of the paper highly depends on the controllability filter, but the supervisory signal of this filter comes from different sources in the two environments: BuildingEnv relies on simulator counterfactuals, while CoGenEnv relies on the manual mapping of fault types to the state dimension. Although this heterogeneous supervision scheme is practical, it also indicates that the method has not yet demonstrated a unified, weakly prior, and scalable filter learning paradigm.
  2. The binaryization step of the filter may introduce threshold sensitivity, but this aspect has not been adequately analyzed. The paper uses a fixed threshold c_filter to convert the continuous controllability score into a mask, but it does not demonstrate the impact of threshold changes on recovery, false creation, or adapter reuse. This makes the robustness of the method unclear.
  3. The conclusions of the continuous learning section mainly come from individual 60-day protocols and 14-day protocols. Figure 3 shows a good behavior of adapter reuse, but the current evidence is still insufficient to determine whether the capacity limit of the library and the merge mechanism will lead to performance degradation in a longer time domain, a larger drift catalog, or more frequent distribution switching.
Questions
  1. When the filter mistakenly suppresses the truly controllable residual dimensions, how will DARPAN recover?
  2. When the new drift mode partially overlaps with the historical mode but is not exactly the same, is the current cosine-similarity routing prone to mistakenly reusing the adapter?
  3. If there are long-term but uncontrollable systematic deviations during the deployment process, will DARPAN continue to accumulate invalid adapters, or will the merge mechanism be sufficient to control the degradation of the library?
Limitations

yes

Final justification

The authors have seriously addressed the issues I raised regarding filter errors and cosine-similarity routing. I maintain a positive opinion of the paper. Based on the feedback, I have made improvements.

Formatting concerns

No

3 comments
Authors · CommentOpenReview ↗

We thank the reviewer for raising important questions about DARPAN’s robustness under imperfect filtering and routing.


Question 1: When the filter mistakenly suppresses the truly controllable residual dimensions, how will DARPAN recover?

The filter decision is recomputed at every timestep from the current state, action, and residual, so mistakenly suppressing a controllable dimension once does not remove it permanently. If that dimension is recognized as controllable at later steps, it again contributes to the filtered residual and the adapter can resume learning from it. The drift signature also aggregates the filtered residual over H=12H=12 steps, which limits the influence of isolated masking errors.

If the filter persistently suppresses that dimension, it will not contribute to adapter routing or updating, reducing the achievable recovery on that component. This is a conservative failure mode because DARPAN forgoes adaptation from the suppressed signal rather than directly adapting to a component judged uncontrollable. Persistent false suppression therefore limits recovery and remains an important source of filter error.


Question 2: When the new drift mode partially overlaps with the historical mode but is not exactly the same, is the current cosine-similarity routing prone to mistakenly reusing the adapter?

Partial overlap can cause an existing adapter to be selected, but this does not necessarily constitute incorrect reuse. DARPAN compares drift signatures in filtered-residual space and reuses an adapter only when the cosine similarity exceeds τ=0.91\tau=0.91, indicating that the new drift has a closely aligned filtered-residual signature with a historical mode. The selected adapter continues to be updated online, allowing it to adjust to differences in the new drift. If the new signature remains below the similarity threshold for Kcreate=24K_{\mathrm{create}}=24 consecutive steps, DARPAN creates a separate adapter. Therefore, continued adaptation and persistent-novelty detection reduce the risk of unsuitable reuse. However, a partially overlapping drift that remains above the similarity threshold may continue to reuse the same adapter, which we recognize as a limitation of the current routing rule.


Question 3: If there are long-term but uncontrollable systematic deviations during the deployment process, will DARPAN continue to accumulate invalid adapters, or will the merge mechanism be sufficient to control the degradation of the library?

Long-term uncontrollable deviations are primarily handled by the controllability filter rather than by the merge mechanism. Because non-action-sensitive residuals are suppressed before the drift signature is formed, they should not repeatedly trigger adapter creation. In our disturbance-only evaluation, DARPAN produced only 1.20±0.451.20 \pm 0.45 false creations, compared with 30.60±5.5930.60 \pm 5.59 when the filter was removed, showing that filtering substantially limits unnecessary library growth. The current evaluations therefore indicate that filtering is the main safeguard against invalid adapter accumulation, while the library-capacity and merge rules provide an additional bound on library growth.

Authors · CommentOpenReview ↗

We thank the reviewer for focusing on the generality and long-term robustness of the filter and adapter library.

Filter supervision. The two environments use different supervision routes, but both estimate the same quantity: whether each residual component changes with the controller’s action. In BuildingEnv, this is learned from simulator counterfactuals without fault labels or access to the evaluation fault catalog. CogenEnv uses a fault-to-dimension mapping only because its ONNX interface does not support the same counterfactual procedure. We agree that the current paper does not yet demonstrate a single weakly supervised procedure for all physical systems.

Threshold sensitivity. We use the same threshold, cfilter=0.50c_{\mathrm{filter}}=0.50, in both environments. The mask is recomputed at every timestep, and the drift signature averages filtered residuals over H=12H=12 steps, reducing the effect of isolated threshold errors. Our no-filter ablation provides an extreme boundary case: replacing the learned mask with an all-ones mask reduces recovery to 20.3±3.4%20.3\pm3.4\% and increases false creations from 1.20±0.451.20\pm0.45 to 30.60±5.5930.60\pm5.59. However, this does not establish robustness to gradual threshold changes, and we will identify a controlled threshold-sensitivity study as important future work.

Long-term library behavior. We agree that the 60-day and 14-day protocols do not establish behavior over arbitrarily long horizons or much larger drift catalogs. The current design limits unnecessary growth through filtered signatures, a similarity threshold of τ=0.91\tau=0.91, a persistence requirement of Kcreate=24K_{\mathrm{create}}=24 steps, and a library capacity of Mmax⁡=40M_{\max}=40. Long-term uncontrollable deviations are primarily handled by the filter before adapter creation, as supported by the disturbance-only false-creation results above.

Reviewer qw9L · CommentOpenReview ↗

Official comment by Reviewer qw9L

Dear authors:

Thank you for the detailed reply. My three concerns were all satisfactorily addressed. Although, the method still has some limitations for Q2 as the authors honestly acknowledge. I will maintain my score but raise my confidence.

Reviewer m4CWOpenReview ↗
Rating
3/6
Confidence
4/5
Quality
2/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
use_inspired
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The paper proposes DARPAN (Drift Aware Residual Policy Adapter Network), a method for online adaptation of pretrained Decision Transformer controllers in physical control systems (building HVAC, cogeneration) subject to deployment time drift such as actuator faults, sensor bias, actuation delays, and weather variation. The key premise is that not all prediction error should drive adaptation: only the portion of the residual that is action sensitive (controllable) should update the policy, while residuals caused by uncontrollable external disturbances should be ignored.

The architecture keeps the pretrained Decision Transformer frozen and adapts through lightweight residual adapters. A controllability filter C(xt,at,rt+1)C(x_t, a_t, r_{t+1}), trained offline via counterfactual simulation (varying action while holding context fixed), scores each dimension of the prediction residual by how strongly it relates to the control action. High scoring dimensions pass through; low scoring dimensions are suppressed. A short history of filtered residuals forms a drift signature used to select from a library of adapters or, if a persistent novel pattern appears, to create a new one.

Evaluation on SustainGym's BuildingEnv (5 zone HVAC) and CogenEnv (combined heat and power) under a 60 day protocol with rotating faults shows DARPAN recovers 31.7 percent of drift induced performance loss using 63 percent fewer online parameters than an "Online DT" baseline. The ablation study is well designed, showing that each component (filter, history, expansion rule, adapter specialization) addresses a qualitatively distinct failure mode.

Strengths and weaknesses

Strengths

  • Well motivated core question. The idea that online adaptation should be selective, responding only to the action sensitive part of prediction error, is principled and underexplored in the pretrained controller adaptation literature. The connection to the classical matched vs. unmatched disturbance distinction in control theory is apt.
  • Clean modular architecture. Frozen backbone plus lightweight adapters plus controllability filter plus adapter library plus drift signature: each piece has a clearly defined role, and the ablation in Table 3 demonstrates these roles are non redundant by showing qualitatively distinct failure modes when each is removed. This is genuine design validation.
  • Practical parameter efficiency. The adapter sizes (142 and 496 parameters for the two environments) are extremely small compared to the pretrained backbone, making the method plausible for deployment on edge hardware in building control applications.
  • Relevant evaluation protocol. The 60 day rotating drift schedule with mixed fault types, including compound faults, is more realistic than single perturbation evaluations. SustainGym is a credible domain benchmark for the Use Inspired contribution type.
  • Ablation study is well designed. Each removed component produces a distinct pathology (no filter causes false adaptation, no history causes instability, naive expansion causes bloat, global adapter causes catastrophic forgetting), demonstrating the components address orthogonal failure modes.

Quality (is the design matched to the use case? are claims well supported?)

  • All deployment hyperparameters are unspecified. The filter threshold cfilterc_{\text{filter}}, history length HH, corrective strength α\alpha, regularization weight λ\lambda, adapter MLP layer sizes, cosine similarity threshold for adapter matching, and the persistence criterion for adapter creation are all named as design parameters but never assigned numerical values anywhere in the paper or appendix. Since the paper reports exact parameter counts (for example, 142 for BuildingEnv), the architecture must be known, yet it is undisclosed. Appendix F.5 discusses these parameters qualitatively ("if too low... if too high...") without stating what values were used.
  • Filter trained on the same fault catalog used in evaluation. For CogenEnv, the controllability filter is trained on labeled fault trajectories from the same catalog used in evaluation (Table 9). The filter has therefore already learned the specific residual patterns it encounters at test time. The strong results (96 percent reduction in false creations) may partly reflect in distribution pattern recognition rather than a general ability to separate controllable from external residuals.
  • No per fault type recovery breakdown. The 31.7 percent headline recovery means roughly two thirds of the drift induced gap remains unrecovered. Without decomposing this across the individual fault segments in the 60 day protocol (weak actuator, sensor bias, delay, stuck actuator, compound), the reader cannot assess whether DARPAN succeeds uniformly or excels on some drift types while failing on others.
  • Adapter trained through a mismatched frozen predictor. The adapter is trained by backpropagating through the frozen predictor FF, which was learned under clean offline dynamics. Under actuator weakening, FF overestimates action sensitivity, so the gradient direction is qualitatively correct but the magnitude is miscalibrated. Under actuation delay, FF associates action effects with the wrong timestep entirely, making the gradient potentially misleading. The paper includes delay in the evaluation (days 16 to 20 and 36 to 40) but does not discuss whether training through a temporally mismatched predictor remains sound.
  • Baseline tuning details missing for negative recovery methods. Online PPO and Full Online DT show negative recovery (they worsen performance relative to the frozen controller). While this supports the narrative, it raises a tuning concern. Online PPO learning from scratch over 60 days in a slow physical system may simply be undertrained; Full Online DT's degradation might reflect an inappropriate learning rate. Without reporting the hyperparameter search for these baselines, the comparison may overstate the difficulty of online adaptation.
  • The 63 percent parameter claim is ambiguous and environment specific. The figure is consistent only with comparing DARPAN's BuildingEnv parameters (142) to Online Head DT's BuildingEnv parameters (390), giving 1−142/390=63.6%1 − 142/390 = 63.6\%. The unqualified "Online DT" in the abstract most naturally refers to the full fine tuning baseline (387,503 params, yielding 99.96 percent fewer). Furthermore, the 63 percent does not hold for CogenEnv (1−496/975=49%1 − 496/975 = 49\%). This makes the abstract's headline claim specific and baseline ambiguous.

Clarity

  • Symbol rtr_t overloaded for reward and residual. Appendix B uses rtr_t for the scalar per step reward (Rt=∑t′=tT−1rt′R_t = \sum_{t'=t}^{T−1} r_{t'}) while Section 3 uses rt+1r_{t+1} for the vector valued prediction residual (rt+1=xt+1−x^t+1r_{t+1} = x_{t+1} − \hat{x}_{t+1}). Since rtr_t is standard RL notation for reward, this overloading creates confusion between the method section and the training appendix.
  • Relationship between the DT state head and predictor FF is unclear. The Decision Transformer includes a multi horizon state prediction head (horizons 1, 3, 6, 12) and the deployment loop uses a "frozen short horizon predictor FF." Are they the same model (the DT's own 1 step state head) or a separately trained predictor?
  • Adapter creation rule never quantified. The persistence criterion is described only qualitatively ("persists for several consecutive steps"). Neither the number of consecutive novel signature steps nor the cosine similarity threshold for matching is stated, making the ablation comparison in Table 3 unreproducible.
  • Recovery metric undefined for disturbance only phases. The "Recovery change" metric in Table 2 is reported during disturbance only phases where no controllable drift is present, but its definition in that setting (particularly what constitutes the reference penalty when external disturbances are active and unavoidable) is never stated. The standard deviations are enormous relative to the means (54.4 on 50.5).
  • False creation counts differ between Tables 2 and 3. Table 2 reports DARPAN false creations as 1.20±0.451.20 \pm 0.45; Table 3 reports Full DARPAN as 1.4±0.91.4 \pm 0.9. Both should reflect the same method on the same metric?

Significance (does it address a difficult task better than previous work? impact for practitioners?)

  • The question of what signal online adapters should learn from is important and underexplored; answering it well would benefit the broader RL and control communities.
  • For the sustainability/building control community, the method is practical (low parameter, modular, preserves offline policy). However, without per fault type breakdowns, practitioners cannot assess whether DARPAN will help with their specific drift type. The unspecified hyperparameters also prevent adoption.
  • The connection to matched versus unmatched disturbances in classical control is mentioned in a single sentence but underdeveloped. Expanding this would ground the contribution in established control theory and make the approach appear principled rather than heuristic, substantially raising the perceived impact.
  • No absolute physical units (degrees Celsius, degree hours) are reported for comfort violations, so a practitioner cannot assess the real world magnitude of the improvement.

Originality (per Use Inspired guidelines: novel framing or combination matched to use case)

  • The controllability filter concept, deriving the adaptation signal from the action sensitive portion of prediction error rather than raw error, is a novel framing that reflects genuine engagement with the physical structure of the problem.
  • The adapter library with drift signatures for selection and creation is less novel (related to modular/contextual adaptation in meta RL), but its integration with the controllability filter is coherent.
  • The ablation partially satisfies "discussion should analyze why certain methodological choices are effective or ineffective." by showing orthogonal failure modes, though per fault type analysis would complete the picture.
Questions

The following questions are ordered by how decisively a satisfying answer would move my score upward.

  1. Deployment hyperparameters. Can you provide a table listing the numerical values of cfilterc_{\text{filter}}, HH, α\alpha, λ\lambda, adapter MLP architecture (layer sizes and activations), cosine similarity threshold, and persistence step count used for each environment? Without this, no reader can reproduce the method.
  2. Out of distribution filter evaluation. Can you evaluate the controllability filter on at least one held out drift type not represented in filter training data (for example, train the CogenEnv filter without wind shift faults and evaluate on a wind shift segment)? This would test whether the filter generalizes beyond its training catalog and address whether the strong results in Table 2 reflect genuine controllability separation versus in distribution pattern recognition.
  3. Per fault type recovery breakdown. Can you report recovery separately for each fault segment (weak actuator, sensor bias, delay, stuck actuator, compound) in both environments? This would reveal where the remaining 68 percent gap originates and whether the predictor mismatch under delay specifically degrades adapter training.
  4. Predictor gradient under delay. The frozen predictor associates action effects with the wrong timestep under actuation delay. Does the adapter training gradient remain useful in this regime? If per fault type results are provided and delay segments show low recovery, this would support the hypothesis that the method's ceiling is partly caused by temporal predictor mismatch.
  5. Baseline tuning. What hyperparameter configurations were tested for Online PPO and Full Online DT? Do their negative recovery values persist across a range of learning rates and update frequencies?
  6. Clarify the 63 percent claim. Which baseline and which environment does this refer to? If it holds only for BuildingEnv versus Online Head DT, please qualify the abstract accordingly.
  7. Smaller, actionable items. Could you also (a) clarify whether FF is the DT's own 1 step state head or a separate model, (b) resolve the rtr_t overloading, (c) reconcile the Table 2 versus Table 3 false creation counts, (d) define "Recovery change" for disturbance only phases, and (e) state the adapter creation rule quantitatively?

Score change criteria. A full answer to Q1 (deployment hyperparameters) plus a positive result on Q2 (filter generalizes out of distribution) would move my score from borderline reject to borderline accept. Adding Q3 (per fault breakdown) would push toward a clear accept. Conversely, if the filter's performance degrades substantially on held out fault types and no mitigation is proposed, my score would remain at or below the current level.

Limitations

Partially addressed. The paper acknowledges some limitations (single domain, deterministic environment) but the discussion would benefit from:

  • Per dimension controllability assumption. In coupled physical systems (thermal networks with inter zone conduction, power plants with shared steam headers), a dimension may be partially action sensitive in a way that depends on state and coupling structure. A per dimension scalar score cannot capture situations where a "controllable" dimension has a residual caused entirely by an unmeasured external factor (for example, a door opening to an adjacent zone). This limitation and its implications should be discussed.
  • Predictor fidelity under temporal drift. The frozen predictor FF may produce misleading gradients when the drift alters the temporal structure of action effects (for example, actuation delay), not just their magnitude. This is a fundamental challenge for the approach that should be named.
  • Filter training data requirements. The CogenEnv filter requires labeled fault trajectories from a catalog. In deployment settings where novel fault types may occur (ones never seen during filter training), the filter's behavior is unknown.
  • Absolute performance context. Without absolute comfort or cost figures in physical units, a practitioner cannot assess whether the residual performance gap matters operationally.
Formatting concerns

None identified that warrant flagging.

4 comments
Authors · CommentOpenReview ↗

We thank the reviewer for these specific and constructive questions. We address each point below.

Q1. Deployment hyperparameters

Symbol Meaning BuildingEnv CogenEnv
HH Signature history length 12 12
cfilterc_{\mathrm{filter}} Controllability filter threshold 0.50 0.50
τ\tau Cosine similarity threshold (adapter matching) 0.91 0.91
KcreateK_{\mathrm{create}} Persistence step count (adapter creation rule) 24 24
α\alpha Corrective strength 0.8 0.8
λ\lambda Correction-size penalty 10−310^{-3} 10−310^{-3}
Mmax⁡M_{\max} Adapter library capacity 40 40
— Adapter hidden width 8 8
dxd_x Adapter input dimension 10 44
dud_u Adapter output dimension 6 15
— Adapter parameter count 142 495

The adapter architecture is identical across environments: a single hidden layer of width 8, Linear(dx,8)→ReLU→Linear(8,du)\mathrm{Linear}(d_x, 8) \rightarrow \mathrm{ReLU} \rightarrow \mathrm{Linear}(8, d_u). All deployment hyperparameters above are shared across both environments; the two differ only in input/output dimensions, yielding 142 parameters for BuildingEnv and 495 for CogenEnv (correcting a minor typo in our original 496). Kcreate=24K_{\mathrm{create}} = 24 quantifies the adapter creation rule described qualitatively in the submission. The Mmax⁡M_{\max} capacity bound is disabled in the naive-expansion ablation.

Q2. Out-of-distribution filter evaluation

We first clarify that this concern applies to the CogenEnv. In BuildingEnv, the filter is trained entirely from simulator counterfactuals by varying actions and external conditions, without observing fault identities or using the evaluation fault catalog. CogenEnv uses fault-to-dimension supervision only because its ONNX interface does not provide the same counterfactual reset capability.

Following the reviewer’s suggestion, we are working on this experiment by removing all trajectories containing the wind-shift component, including standalone F5 and compound F7, while retaining standalone F1 turbine-degradation data. We will compare recovery and false-adapter creations against the full-catalog filter, and provide the corresponding segment-level CogenEnv recovery values and update the results in the comments once the experiment is complete.

Q3. Per-fault-type recovery breakdown

We measured recovery separately for each fault segment across five runs.

Weak actuation. Recovery decreases as the fault becomes more severe 48.5±1.6%48.5 \pm 1.6\% (mild), 28.0±1.7%28.0 \pm 1.7\% (medium), and 11.3±2.0%11.3 \pm 2.0\% (severe). When a severe fault limits a heater to a fraction of its nominal capacity, the adapter outputs a large compensatory correction that pushes the command toward the relevant action limit. Because the actuator itself is degraded, however, even the limiting command cannot restore the lost thermodynamic capacity. Stuck actuators. Recovery is 8.9±2.1%8.9 \pm 2.1\% (moderate) and 3.1±1.4%3.1 \pm 1.4\% (strong). A stuck actuator substantially restricts or removes control over the affected channel, so a correction in that dimension has little or no effect on its output.

Sensor bias. Recovery is 37.4±1.1%37.4 \pm 1.1\%, 41.9±4.4%41.9 \pm 4.4\%, and 48.2±1.1%48.2 \pm 1.1\% across the three segments. The increase to 48.2%48.2\% occurs on a recurrence of the warmer bias.

Compound faults. 31.3±2.4%31.3 \pm 2.4\%.

Action delay. Recovery is 63.3±1.3%63.3 \pm 1.3\% (short delay) and 40.4±14.9%40.4 \pm 14.9\% (long delay).

This result must be interpreted alongside the absolute loss of physical control capacity. We want to give an illustrative example here, suppose a severe fault limits a heater to 30%30\% of its nominal capacity. At time tt, zone 1 is at 19.5∘C19.5^\circ\mathrm{C} with a target of 21.0∘C21.0^\circ\mathrm{C}. The frozen Decision Transformer requests a strong heating action, atbase[1]=0.85a_t^{\mathrm{base}}[1]=0.85. The adapter correctly recognizes the under-response from the drift signature and outputs a large compensatory correction, Δat[1]=0.40\Delta a_t[1]=0.40. The deployed action hits the physical upper bound: at[1]=clip(0.85+0.40)=1.0a_t[1]=\mathrm{clip}(0.85+0.40)=1.0. However, because the actuator is severely damaged, this maximum command only raises the temperature to T1(t+1)=19.7∘CT_1(t+1)=19.7^\circ\mathrm{C}.

Q4. Predictor gradient under actuation delay

DARPAN does not model actuation delay because the adapter computes Δat=f(xt)\Delta a_t=f(x_t) from the current state without directly conditioning on recent action history.The temporal drift signature summarizes filtered residual steps for adapter selection, and the online correction remains empirically useful(63.3±1.363.3\pm1.3% recovery under the short delay and 40.4±14.940.4\pm14.9% under the longer delay). To examine whether temporal predictor mismatch specifically reduces recovery, we repeated the long-delay segment with the delay removed while holding the remaining conditions fixed. Recovery was 42.0±5.642.0\pm5.6%, compared with 40.4±14.940.4\pm14.9% under delay.

Authors · CommentOpenReview ↗

Q5. Baseline tuning for Online PPO and Full Online DT

We clarify that the negative recovery values indicate failure to recover within the fixed deployment budget, rather than evidence that these methods cannot eventually adapt. Online PPO learned from scratch using a learning rate of 3×10−43\times10^{-4}, batch size 6464, 1010 optimization epochs, and γ=0.99\gamma=0.99. Full Online DT was initialized from the same pretrained Decision Transformer and updated all 387,503387{,}503 parameters using AdamW with a learning rate of 10−510^{-5}. We report the configurations used in our experiments and interpret the results within the same fixed deployment budget applied to all methods.

BuildingEnv provides 288288 control steps per day and 17,28017{,}280 steps over 60 days, with each drift segment lasting only five days. CogenEnv is even more constrained, providing 9696 control steps per day and 1,3441{,}344 steps over the 14-day protocol, with most fault conditions lasting only one day. Thus, in both environments, an adaptation method must improve while the drift is active rather than relying on a long training horizon. Online PPO is included primarily as a from-scratch reference. The closer comparisons are Full Online DT, Online-Head DT, LoRA-DT, and Hyper-DT, which all begin from the same pretrained backbone.

Full Online DT updates the entire controller from a short and non-stationary stream of deployment data. Its negative recovery is consistent with unrestricted updates overwriting useful pretrained behavior before sufficient online evidence is accumulated.

To verify that this is a time constraint rather than a tuning failure, we extended Full Online DT to 180 days of continuous operation (three times the protocol length, and approximately six months of real-world time), which raised recovery to roughly 10%10\%. The method does learn, it simply requires an adaptation window that is operationally unacceptable, since every month of adaptation is a month of degraded comfort or cost for the end user.


Q6. The 63% claim clarification

The 63% reduction refers specifically to BuildingEnv, where DARPAN updates 142 parameters compared with 390 parameters for the Online-Head DT baseline, corresponding to 63.6% fewer trainable parameters. We agree that the original wording was ambiguous because Online DT could be interpreted as the full fine-tuning baseline. We wanted to compare with Online-Head DT because it is strongest competitor in terms of parameter cost. We will revise the abstract accordingly.


Q7. Smaller actionable items

We address each of the five points below and will revise the manuscript accordingly.

[a] Identity of the short-horizon predictor. The frozen predictor is a separately trained, action-conditioned one-step dynamics model. It is not the Decision Transformer's auxiliary multi-horizon state-prediction head. Only the standalone predictor participates in the deployment loop. We will clarify this in Section 3 and report its architecture and training configuration in the appendix.

[b] Notation overload. We agree and will retain rtr_t for the scalar reward and RtR_t for return-to-go, while renaming the vector-valued prediction residual as et+1e_{t+1} throughout the paper.

[c] False-creation counts in Tables 2 and 3. The values 1.201.20 and 1.401.40 were obtained from separate seed sets for the same DARPAN configuration. All variants within Table 3 were evaluated using a common run set, so its ablation comparisons remain internally consistent. In the revision, we will report both tables using a single consolidated run set.

[d] Recovery Change during disturbance-only phases. During disturbance-only phases, the normalized Recovery metric is not applicable because there is no controllable drift-induced gap to recover. We therefore report the unnormalized penalty difference

ΔPdist=Pfrozen−Pmethod\Delta P_{\mathrm{dist}} = P_{\mathrm{frozen}} - P_{\mathrm{method}}

evaluated over the same disturbance phase. Positive values indicate a lower penalty than the frozen controller. We will distinguish this quantity from the normalized Recovery metric in the table caption.

[e] Adapter creation rule. A drift signature is treated as novel when its cosine similarity to every stored adapter signature falls below τ=0.91\tau=0.91. A new adapter is created only when this condition holds for Kcreate=24K_{\mathrm{create}}=24 consecutive control steps. Otherwise, the closest existing adapter is selected. We will add these values to the revised method description.


Authors · CommentOpenReview ↗

Limitations

We will expand the limitations discussion to clarify the scope of the current formulation.

First, the per-dimension controllability mask is an approximation in strongly coupled systems, where control effects and modeling errors may propagate across state dimensions [1]. A related ambiguity is already noted in Appendix F.6, which discusses cases where controllable faults and external disturbances produce nearly identical residuals in the observed state. We will move this point into the main limitations discussion and identify state-dependent or cross-dimensional controllability estimation as a natural extension.

Second, the current one-step predictor and state-conditioned adapter do not explicitly model recent action history. Delay can change the temporal structure of the control problem and may require delay-aware state representations or predictors [2,3]. As discussed in our response to Q4, DARPAN retains positive recovery under both short and long delays, but the current analysis does not isolate the predictor-gradient effect. We will therefore describe temporal mismatch as a limitation of the current formulation rather than draw a stronger causal conclusion.

Third, CogenEnv uses fault-to-dimension supervision because its ONNX interface does not support the counterfactual procedure used in BuildingEnv. Its generalization to fault components absent from that catalog requires direct evaluation, which is the purpose of the held-out wind-shift experiment described above. Public HVAC datasets containing faulted and fault-free trajectories from simulation, laboratory facilities, and field operation [4] also provide useful data sources for studying filter supervision from measured system trajectories.

Finally, we agree that normalized recovery does not by itself provide a complete operational interpretation. DARPAN is intended to apply beyond a single environment-specific objective, so we use recovery to measure the fraction of the Frozen-DT-to-reference penalty gap closed and to enable consistent comparison across environments with different objective scales and penalty definitions.


References:

[1] Ercan Atam. Decentralized thermal modeling of multi-zone buildings for control applications and investigation of submodeling error propagation. Energy and Buildings, 126:384–395, 2016.

[2] Jean-Pierre Richard. Time-delay systems: An overview of some recent advances and open problems. Automatica, 39(10):1667–1694, 2003.

[3] Pierre Liotet, Davide Maran, Lorenzo Bisi, and Marcello Restelli. Delayed reinforcement learning by imitation. In Proceedings of the 39th International Conference on Machine Learning, pages 13528–13556, 2022.

[4] Jessica Granderson, Guanjing Lin, Yimin Chen, Armando Casillas, Jin Wen, Zhelun Chen, Piljae Im, Sen Huang, and Jiazhen Ling. A labeled dataset for building HVAC systems operating in faulted and fault-free states. Scientific Data, 10:342, 2023.

Authors · CommentOpenReview ↗

Question 2: Out-of-distribution evaluation of the CogenEnv filter.

Given the importance of this question, we expanded the leave-one-mechanism-out evaluation beyond the suggested wind-shift experiment to four distinct mechanism families, covering wind shift, sensor drift, GT1 degradation, and multi-turbine degradation. For each condition, we retrained the controllability filter from scratch after removing every filter-training trajectory containing the held-out mechanism, including all compound trajectories in which that mechanism appeared. The evaluated mechanism was completely absent from the filter-training data.

The filter is not given a fault identity or fault class. It computes a per-dimension controllability score directly from the current state, the applied base action, and the resulting prediction residual:

pt+1=C(xt,atbase,rt+1),rt+1=xt+1−F(xt,atbase)p_{t+1} = C\left(x_t, a_t^{\mathrm{base}}, r_{t+1}\right), \qquad r_{t+1} = x_{t+1} - F\left(x_t, a_t^{\mathrm{base}}\right)

The results below show that exact exposure to the evaluated mechanism is not required, we will add this analysis to the revised manuscript.


Table: Leave-one-mechanism-out evaluation of the CogenEnv controllability filter. False adaptation rate is reported for exogenous segment that trigger an adapter update. Recovery is reported for controllable or compound segments.

Held-out mechanism Evaluation segment Metric Full catalog Held out
Wind shift F5 False adaptation rate (%) 1.3 ± 0.5 3.4 ± 0.6
Wind shift F7 Recovery (%) 48.5 ± 3.4 46.9 ± 6.8
Sensor drift F3/F4 False adaptation rate (%) 2.6 ± 0.2 4.9 ± 0.3
Sensor drift F8 Recovery (%) 46.0 ± 2.7 44.3 ± 3.2
GT1 degradation F1 segments Recovery (%) 43.6 ± 3.3 46.1 ± 3.1
Multi-turbine degradation F2 Recovery (%) 34.8 ± 2.3 34.2 ± 4.9
Active-fault aggregate Controllable/compound segments Recovery (%) 38.4 ± 1.8 37.2 ± 3.9

Aggregation note. The final row reports penalty-gap-weighted recovery only over controllable and compound fault segments. The 28.5% result in Table 1 is computed from the full 14-day rollout. It also includes clean and exogenous segments, so it is lower than the active-fault result and is not an average of the segment-level percentages.


Holding out wind shift increased false adaptation on F5 from 1.3% to 3.4%, while holding out sensor drift increased it on F3/F4 from 2.6% to 4.9%. Even without these mechanisms in training, 96.6% and 95.1% of timesteps did not trigger an adapter update. Compound-fault recovery changed only slightly. F7 changed from 48.5% to 46.9%, and F8 changed from 46.0% to 44.3%. Recovery also remained stable for held-out controllable faults. GT1 degradation changed from 43.6% to 46.1%, and multi-turbine degradation changed from 34.8% to 34.2%. Overall active-fault recovery changed from 38.4% to 37.2%.

Coming to per fault recovery for Cogen, DARPAN achieves 42.3% recovery on mild GT1 degradation, 38.0% on severe GT1 degradation, 22.7% on HRSG fuel-response degradation, and 34.8% on multi-turbine degradation. Recovery remains strong on the compound F7 and F8 faults at 48.5% and 46.0%, respectively.The final recurring GT1 segment reaches 57.8%, consistent with reuse of an earlier adapter.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.