Calibrating Agentic LLMs for Clinical Prediction
Zheqi Lv, Fuying Ding, Meihan Wei, Haoyang Li, Christos Faloutsos, Fei Wang, Chengxi Zang
Abstract. Agentic Large Language Models (LLMs) show great promise in clinical prediction using real-world clinical data. While recent studies have primarily examined their discrimination performance, their calibration performance—that is, whether predicted probabilities accurately reflect absolute clinical risk—remains largely unknown. This gap limits their use in high-stakes medical settings, where well-calibrated risk estimates are essential for guiding treatment and prevention decision-making. In this work, we provide conditional theoretical analyses of how agentic LLM architectures, task knowledge, and tool use affect calibration performance in clinical prediction. Motivated by these analyses, we propose C²Align, a Calibrated and Clinically Aligned framework, to optimize calibration while maintaining or even improving discrimination. C²Align aligns two complementary agent branches: an ensemble of task-homogeneous LLM agents and a set of clinical task-inspired LLM agents. This alignment is achieved through a novel discrimination- and calibration-aware loss that encourages clinically meaningful agreement while controlling probabilistic miscalibration. We evaluate this framework on four clinical prediction benchmarks—spanning prognostic prediction and disease diagnosis tasks—using diverse LLMs, agent architectures, and calibration methods over both MIMIC-III and IV datasets, and on an external in-hospital mortality cohort from an independent hospital (TJH). Extensive experiments, supported by theoretical motivation under assumptions, demonstrate that C²Align improves calibration while maintaining or enhancing discrimination. Our work provides a theoretical, methodological, and benchmark reference for developing well-calibrated agentic LLMs for trustworthy clinical prediction.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 5 reviews · OpenReview
Updated 25 Nov 2026, 03:49 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
Summary. The paper studies calibration in clinical prediction, namely whether a model’s predicted probabilities accurately reflect the true clinical risk, rather than only whether the model can correctly distinguish between classes. This is important in clinical settings because well-calibrated probabilities can help clinicians understand the severity and urgency of a patient’s condition. The authors propose a multi-agent LLM framework with two branches: a parallel branch of similar agents and a specialist branch that extracts task-specific clinical information from both structured and unstructured EHR data. The outputs of these branches, together with the original structured features, are then used by a lightweight and interpretable machine-learning model to make the final prediction. The model is trained using three objectives: (1) a discrimination loss based on cross-entropy, (2) a proposed calibration loss based on the Brier score, and (3) a proposed dual-view alignment loss that aligns the final model with the predictions of the two agent branches. The authors evaluate the method on diagnosis and prognosis tasks using the MIMIC-III and MIMIC-IV datasets and compare it with traditional machine-learning models, LLM-based methods, multi-agent architectures, and existing calibration approaches.
Strengths.
1. Important and well-motivated problem. The paper studies calibration of agentic LLMs for clinical prediction, which is important because accurate probability estimates are necessary for trustworthy clinical decision-making. The paper explains why strong discrimination alone is insufficient and why poorly calibrated predictions can be harmful in healthcare.
2. Reasonable method design and evaluation. The proposed framework combines parallel agents, specialist agents, and a downstream machine-learning model in a way that is reasonably matched to the clinical prediction setting. The evaluation covers both diagnosis and prognosis tasks, multiple LLM backbones, different agent architectures, and a few calibration baselines. The results generally show improvements in both calibration and discrimination.
Weaknesses.
1. Missing experimental details and no reproducibility. The paper does not clearly explain how the data were split, whether the split was done at the patient level, how cross-validation was done, how many folds were used, or whether the same patient could appear in both training and test sets. It also does not clearly report the exclusion rules, class balance, and prediction time. The paper should also explain how the custom XGBoost loss was implemented. The checklist says that the code is available, but no code link is provided.
2. Limited statistical evidence. The test sets are small, but the paper reports only single performance values. It does not provide confidence intervals, repeated runs, or significance tests. Although the LLM generation is deterministic, XGBoost training and grid search can still introduce variation. It is therefore unclear whether the reported gains are stable.
3. Limited calibration analysis. The paper mainly reports Brier score and ten-bin ECE. It does not report confidence bands for the reliability plots, results under different binning choices, or calibration for different patient groups as MIMIC provides the demographics. Since calibration is the main topic of the paper, this analysis should be more complete.
4. Limited evidence of generalization. All tasks use MIMIC-III or MIMIC-IV. These datasets come from the same hospital and overlaps. The paper does not explain whether the Readmission-III and Readmission-IV cohorts may contain some of the same patients. Testing on another hospital, another time period, or another related dataset would provide stronger evidence.
5. Strong assumptions in the theory. The theoretical part depend on assumptions that may not hold in practice. For example, the paper assumes that the parallel branch is not worse in discrimination, that the specialist features contain the important clinical information, and that the agent outputs are useful and not harmful. The experiments do not provide enough evidence that these assumptions hold. Add clear ablations.
6. The intermediate agent outputs are not evaluated. The paper does not report the extraction accuracy of the specialist agents, their agreement with human reviewers, or how often they produce hallucinations, invalid JSON, missing values, or failed outputs. Add clear ablations on the results of the LLM branches.
7. Unclear privacy and data protection. The paper appears to use external LLM APIs, such as OpenAI GPT-4o, with MIMIC data. However, the PhysioNet license says that users must not share restricted data with third parties and must keep the data secure. The paper does not explain how the data were protected. The authors should state whether the APIs used Zero Data Retention and how they protected the data.
8. Writing and presentation need improvement. Reviewers state that method description is difficult to follow, and the connection between the theory, method, and experiments is not always clear. Some figures and tables are too small or crowded or not referenced. The paper also mentions DeepSeek-V4 but cites a DeepSeek-V3 reference.
9. The baseline comparison does not clearly show where the gains come from. The proposed framewrok uses structured features, clinical notes, extracted features, and agent probabilities, while the main ML baselines use only structured features. This makes it hard to know whether the gains come from the proposed method or from using more information. Some gains over the strongest baseline are also small, and the paper does not report confidence intervals or significance tests. The authors should add input-matched baselines and test each auxiliary loss separately, including the Brier loss and the two KL alignment losses. They should also report uncertainty for the main results.
Final justification
Strengths.
-
Important and well-motivated problem. Calibration is important for clinical prediction because a model can rank patients correctly while still giving misleading risk values. The paper clearly explains this problem and studies calibration together with discrimination.
-
Reasonable method and broad evaluation. The proposed method combines parallel agents, specialist agents, and a downstream model in a reasonable way for the clinical setting. The evaluation covers several tasks, LLM backbones, agent architectures, and calibration methods.
-
The paper was improved during rebuttal. The authors added confidence intervals and additional calibration measures, subgroup results, prompt-sensitivity experiments, an external evaluation, efficiency results, input-matched comparisons, and additional analysis of the specialist agents. They also provided an anonymized code repository and clarified the patient-level data splitting and the custom XGBoost objective. These additions address many of the main experimental and reproducibility concerns raised in the initial reviews.
Remaining weaknesses.
-
The theory still depends on strong assumptions. This is the main remaining concern. If these assumptions do not hold, the conclusions of the theorems may also not hold. The authors added useful experiments to support the assumptions, but these only provide empirical evidence on the tested settings and do not make the assumptions hold in general. Reviewer o6bT raised this concern throughout the discussion and still had some concerns after the rebuttal. The authors should present the theory mainly as conditional motivation rather than general guarantees. They should also clearly separate the ideal objects used in the theory from their practical LLM-based approximations.
-
Possible overlap between MIMIC-III and MIMIC-IV is not fully resolved. The authors ensure patient-level separation within each dataset, but they cannot reliably identify overlapping patients across the two MIMIC releases. Reviewer 69dK kept this as a remaining concern. The paper should clearly state this limitation and avoid treating MIMIC-III and MIMIC-IV as fully independent evaluations. The added TJH experiment can instead serve as the main external validation.
-
The interpretability claim may be too strong. The downstream ML model is relatively interpretable, but some of its inputs are produced by black-box LLM agents. Reviewer o6bT also raised this concern. The authors should make clear that the downstream model is interpretable, rather than suggesting that the full C2Align pipeline is fully interpretable.
Author response and reviewer discussion.
-
Most experimental and reproducibility concerns were addressed. The authors clarified the patient-level splits and cross-validation, exclusion rules, prediction timing, feature construction, and custom XGBoost objective. They also provided an anonymized code repository with the main implementation details.
-
The authors added many of the requested experiments. They added confidence intervals and additional calibration metrics, subgroup analysis, prompt-sensitivity analysis, specialist-agent quality and failure analysis, efficiency results, input-matched comparisons and ablations, and external validation on the TJH dataset. These additions substantially strengthened the empirical evaluation.
-
The privacy and data-use concerns were clarified. The authors stated that the study was conducted under an approved IRB protocol and that model inference used approved local systems and enterprise endpoints that prevent provider training, human review, and persistent data retention. They also clarified that protected patient data from MIMIC dataset will not be released.
-
The main remaining disagreement concerns the theory. o6bT stated that most empirical concerns were resolved and that the theoretical claims had been narrowed, but still had concerns about the assumptions behind the theorems. o6bT recommended presenting the theory mainly as motivation and framing the contribution more strongly around the empirical results. I agree with this suggestion.
I recommend Borderline Accept (4). The paper studies an important problem, and the rebuttal addressed most of the experimental, statistical, reproducibility, privacy, and generalization concerns. The main remaining issue is the theory: the three theorems rely on strong assumptions, and the added experiments only support these assumptions in the tested settings. I therefore suggest presenting the theory mainly as conditional motivation rather than as general guarantees, and clearly stating the possible failure cases. Overall, the empirical contribution and the improvements made during rebuttal are sufficient for acceptance.
Read meta-review
Meta-review
Summary. The paper studies calibration in clinical prediction, namely whether a model’s predicted probabilities accurately reflect the true clinical risk, rather than only whether the model can correctly distinguish between classes. This is important in clinical settings because well-calibrated probabilities can help clinicians understand the severity and urgency of a patient’s condition. The authors propose a multi-agent LLM framework with two branches: a parallel branch of similar agents and a specialist branch that extracts task-specific clinical information from both structured and unstructured EHR data. The outputs of these branches, together with the original structured features, are then used by a lightweight and interpretable machine-learning model to make the final prediction. The model is trained using three objectives: (1) a discrimination loss based on cross-entropy, (2) a proposed calibration loss based on the Brier score, and (3) a proposed dual-view alignment loss that aligns the final model with the predictions of the two agent branches. The authors evaluate the method on diagnosis and prognosis tasks using the MIMIC-III and MIMIC-IV datasets and compare it with traditional machine-learning models, LLM-based methods, multi-agent architectures, and existing calibration approaches.
Strengths.
1. Important and well-motivated problem. The paper studies calibration of agentic LLMs for clinical prediction, which is important because accurate probability estimates are necessary for trustworthy clinical decision-making. The paper explains why strong discrimination alone is insufficient and why poorly calibrated predictions can be harmful in healthcare.
2. Reasonable method design and evaluation. The proposed framework combines parallel agents, specialist agents, and a downstream machine-learning model in a way that is reasonably matched to the clinical prediction setting. The evaluation covers both diagnosis and prognosis tasks, multiple LLM backbones, different agent architectures, and a few calibration baselines. The results generally show improvements in both calibration and discrimination.
Weaknesses.
1. Missing experimental details and no reproducibility. The paper does not clearly explain how the data were split, whether the split was done at the patient level, how cross-validation was done, how many folds were used, or whether the same patient could appear in both training and test sets. It also does not clearly report the exclusion rules, class balance, and prediction time. The paper should also explain how the custom XGBoost loss was implemented. The checklist says that the code is available, but no code link is provided.
2. Limited statistical evidence. The test sets are small, but the paper reports only single performance values. It does not provide confidence intervals, repeated runs, or significance tests. Although the LLM generation is deterministic, XGBoost training and grid search can still introduce variation. It is therefore unclear whether the reported gains are stable.
3. Limited calibration analysis. The paper mainly reports Brier score and ten-bin ECE. It does not report confidence bands for the reliability plots, results under different binning choices, or calibration for different patient groups as MIMIC provides the demographics. Since calibration is the main topic of the paper, this analysis should be more complete.
4. Limited evidence of generalization. All tasks use MIMIC-III or MIMIC-IV. These datasets come from the same hospital and overlaps. The paper does not explain whether the Readmission-III and Readmission-IV cohorts may contain some of the same patients. Testing on another hospital, another time period, or another related dataset would provide stronger evidence.
5. Strong assumptions in the theory. The theoretical part depend on assumptions that may not hold in practice. For example, the paper assumes that the parallel branch is not worse in discrimination, that the specialist features contain the important clinical information, and that the agent outputs are useful and not harmful. The experiments do not provide enough evidence that these assumptions hold. Add clear ablations.
6. The intermediate agent outputs are not evaluated. The paper does not report the extraction accuracy of the specialist agents, their agreement with human reviewers, or how often they produce hallucinations, invalid JSON, missing values, or failed outputs. Add clear ablations on the results of the LLM branches.
7. Unclear privacy and data protection. The paper appears to use external LLM APIs, such as OpenAI GPT-4o, with MIMIC data. However, the PhysioNet license says that users must not share restricted data with third parties and must keep the data secure. The paper does not explain how the data were protected. The authors should state whether the APIs used Zero Data Retention and how they protected the data.
8. Writing and presentation need improvement. Reviewers state that method description is difficult to follow, and the connection between the theory, method, and experiments is not always clear. Some figures and tables are too small or crowded or not referenced. The paper also mentions DeepSeek-V4 but cites a DeepSeek-V3 reference.
9. The baseline comparison does not clearly show where the gains come from. The proposed framewrok uses structured features, clinical notes, extracted features, and agent probabilities, while the main ML baselines use only structured features. This makes it hard to know whether the gains come from the proposed method or from using more information. Some gains over the strongest baseline are also small, and the paper does not report confidence intervals or significance tests. The authors should add input-matched baselines and test each auxiliary loss separately, including the Brier loss and the two KL alignment losses. They should also report uncertainty for the main results.
Final justification
Strengths.
-
Important and well-motivated problem. Calibration is important for clinical prediction because a model can rank patients correctly while still giving misleading risk values. The paper clearly explains this problem and studies calibration together with discrimination.
-
Reasonable method and broad evaluation. The proposed method combines parallel agents, specialist agents, and a downstream model in a reasonable way for the clinical setting. The evaluation covers several tasks, LLM backbones, agent architectures, and calibration methods.
-
The paper was improved during rebuttal. The authors added confidence intervals and additional calibration measures, subgroup results, prompt-sensitivity experiments, an external evaluation, efficiency results, input-matched comparisons, and additional analysis of the specialist agents. They also provided an anonymized code repository and clarified the patient-level data splitting and the custom XGBoost objective. These additions address many of the main experimental and reproducibility concerns raised in the initial reviews.
Remaining weaknesses.
-
The theory still depends on strong assumptions. This is the main remaining concern. If these assumptions do not hold, the conclusions of the theorems may also not hold. The authors added useful experiments to support the assumptions, but these only provide empirical evidence on the tested settings and do not make the assumptions hold in general. Reviewer o6bT raised this concern throughout the discussion and still had some concerns after the rebuttal. The authors should present the theory mainly as conditional motivation rather than general guarantees. They should also clearly separate the ideal objects used in the theory from their practical LLM-based approximations.
-
Possible overlap between MIMIC-III and MIMIC-IV is not fully resolved. The authors ensure patient-level separation within each dataset, but they cannot reliably identify overlapping patients across the two MIMIC releases. Reviewer 69dK kept this as a remaining concern. The paper should clearly state this limitation and avoid treating MIMIC-III and MIMIC-IV as fully independent evaluations. The added TJH experiment can instead serve as the main external validation.
-
The interpretability claim may be too strong. The downstream ML model is relatively interpretable, but some of its inputs are produced by black-box LLM agents. Reviewer o6bT also raised this concern. The authors should make clear that the downstream model is interpretable, rather than suggesting that the full C2Align pipeline is fully interpretable.
Author response and reviewer discussion.
-
Most experimental and reproducibility concerns were addressed. The authors clarified the patient-level splits and cross-validation, exclusion rules, prediction timing, feature construction, and custom XGBoost objective. They also provided an anonymized code repository with the main implementation details.
-
The authors added many of the requested experiments. They added confidence intervals and additional calibration metrics, subgroup analysis, prompt-sensitivity analysis, specialist-agent quality and failure analysis, efficiency results, input-matched comparisons and ablations, and external validation on the TJH dataset. These additions substantially strengthened the empirical evaluation.
-
The privacy and data-use concerns were clarified. The authors stated that the study was conducted under an approved IRB protocol and that model inference used approved local systems and enterprise endpoints that prevent provider training, human review, and persistent data retention. They also clarified that protected patient data from MIMIC dataset will not be released.
-
The main remaining disagreement concerns the theory. o6bT stated that most empirical concerns were resolved and that the theoretical claims had been narrowed, but still had concerns about the assumptions behind the theorems. o6bT recommended presenting the theory mainly as motivation and framing the contribution more strongly around the empirical results. I agree with this suggestion.
I recommend Borderline Accept (4). The paper studies an important problem, and the rebuttal addressed most of the experimental, statistical, reproducibility, privacy, and generalization concerns. The main remaining issue is the theory: the three theorems rely on strong assumptions, and the added experiments only support these assumptions in the tested settings. I therefore suggest presenting the theory mainly as conditional motivation rather than as general guarantees, and clearly stating the possible failure cases. Overall, the empirical contribution and the improvements made during rebuttal are sufficient for acceptance.
2 comments
Response to the Meta-Review and Summary of Revisions
Dear Area Chair,
We sincerely thank you and all reviewers for the detailed and constructive feedback. Throughout the discussion period, we engaged extensively with the reviewers and carefully considered the comments and suggestions from both the Area Chair and the reviewers. We have clarified every point and added the discussion into the paper.
The meta-review identified nine principal concerns. Our rebuttal, manuscript revisions, and follow-up materials directly addressed each of them:
-
Experimental details and reproducibility.
We provided the ACs, through the permitted anonymous route, with the reproducibility repository:https://anonymous.4open.science/r/C2Align_repo-3200/
The repository includes cohort-construction logic, prompts with fixed JSON schemas, task-specific feature allowlists, leakage and feature-policy tests, the callable custom XGBoost objective, random seeds, dependencies, and execution entry points. We further clarified that all train/test splits and five-fold cross-validation procedures are grouped at the patient level using
subject_id, with an enforced empty-intersection check, and documented the exclusion criteria and counts. -
Statistical evidence.
We reported 95% confidence intervals based on paired patient-level bootstrap analyses for AUROC, Brier score, and ECE across the evaluated backbones and tasks. We also added repeated-seed and targeted statistical analyses where applicable. -
Calibration analysis.
We added calibration intercept and slope, justified the use of equal-mass binning for finite-sample ECE estimation, reported bootstrap uncertainty for the principal calibration metrics, and provided subgroup calibration and discrimination analyses by age, sex, and race. -
Generalization.
We added external validation using the TJH EHR dataset from an independent hospital and a different clinical endpoint. Under input-matched comparisons in which all methods received the same structured variables, C²Align retained the strongest overall discrimination–calibration balance. -
Theoretical assumptions.
We added targeted empirical verification for all three theoretical results:- paired AUROC-equivalence tests, repeated-seed Brier decomposition, and conditional seed-correlation estimates for Theorem 1;
- a 5,000-field physician audit and a matched representation study for Theorem 2; and
- soft-target corruption analyses and a matched linear-head experiment for Theorem 3.
The physician audit yielded specialist-agent omission and unsupported-assertion rates of 0.60% and 0.70%, respectively, compared with 5.70% and 4.90% for direct LLM reasoning, with Cohen’s .
-
Intermediate agent outputs.
We reported specialist-extraction fidelity, physician agreement, omission and hallucination rates, malformed-output handling, missing-value behavior, API failure rates, and bounded-retry outcomes. -
Privacy and data protection.
We clarified that the study was conducted under an IRB-approved protocol and that inference was restricted to institutionally approved, security-controlled environments and enterprise endpoints that prohibit provider training and human review and prevent persistent retention. We also clarified DUA compliance, non-redistribution of restricted records, and the scope of the released code and derived artifacts, and incorporated the ethics reviewer’s requested clarifications into the revision. -
Writing and presentation.
We rewrote the method as a numbered workflow, clarified that the LLM branches are frozen and that only the downstream model is trained, improved the explanation and referencing of the figures and tables, and revised the presentation to make the connection among the theory, method, and experiments more explicit. -
Baseline comparisons and the source of improvement.
We added input-matched comparisons, component and branch ablations, loss-level comparisons, and targeted controlled analyses separating the effects of structured inputs, specialist representations, branch probabilities, Brier regularization, and dual-KL alignment.
We have incorporated all substantive points raised during the discussion into the revised manuscript, including the clarifications, analyses, experiments, and reproducibility materials summarized above. We believe that the paper has been substantially strengthened through this process.
We sincerely thank you and all reviewers for your time, constructive feedback, and collective effort in helping us improve the paper.
Sincerely,
The Authors
- Rating
- 3/6
- Confidence
- 3/5
- Quality
- 2/4
- Clarity
- 2/4
- Significance
- 2/4
- Originality
- 3/4
- Contribution type
- use_inspired
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper proposes C²Align, a Calibrated and Clinically Aligned framework whose goal is to optimize the calibration of clinical-prediction probabilities while preserving discrimination performance. The framework couples an agentic LLM pipeline (consisting of a set of parallel homogeneous agents and a set of specialist agents) with a lightweight ML model that produces the final calibrated prediction. The paper's main empirical claims are that (i) parallel agentic architectures yield better calibration than sequential ones, (ii) incorporating clinical task knowledge improves calibration, and (iii) tool usage (e.g., calling ML models) further improves calibration.
Strengths and weaknesses
Strengths
- Relevant use case. Calibration in clinical prediction is important.
- Use of a downstream model. Routing the information extracted by the agentic framework through a lightweight model for the final prediction is a nice way of compressing that information, and directly enables controlling the calibration through the loss
Weaknesses
Presentation and structure. The paper is very densely written and not well structured. This makes it hard to identify what the main conceptual contribution is.
Theory. The three theorems are not mathematically wrong, but they share a structural weakness: in each case the assumptions are either taken for granted or violated by the authors' implementation.
- Theorem 1. The proof relies on the assumption that "after controlling for , the sequential architecture does not have a smaller deterministic discrimination term than the parallel architecture." I don't quite understand how this assumption can be made confidently. It assumes the central design decision. Under this assumption the result becomes trivially true, and the formalization adds nothing beyond restating it. A sequential chain-of-thought agent might plausibly extract richer clinical reasoning than independent parallel agents that average out each other's nuance. Am I missing something here?
- Theorem 2. The theorem requires that the features extracted by the specialist agents form a complete and sufficient summary of all clinically relevant information. I'm not super confident in this since the extraction is performed by an LLM that may hallucinate or omit evidence. The assumed Causal Markov Blanket is a formal property of a perfect oracle extractor. The actual deviates from this, and the paper never explains how the two concepts connect so as to make the theorem hold in practice.
- Theorem 3. The theorem requires that "the agentic LLM branches provide non-adversarial and outcome-informative clinical representations or soft targets." This implies the result breaks down when the soft labels are poor, which is a realistic scenario in clinical LLM applications. It requires good agent outputs in order to prove that good calibration follows which is impossible to guarantee in reality
Empirical results.
- Stable inference structure. Its unclear how the method guarantees that always has the same structure within a task. This is crucial for reliable prediction with at inference time and is never addressed.
- Datasets aren't appropriate. The datasets contain no real probabilities. A probability is derived by binning binary decisions. Given that calibration of probabilities is the paper's central claim, this doesn't make a lot of sense to me. In addition, relative percentage improvements over absolute calibration numbers from tiny test sets are not trustworthy. Literature has shown that ECE over sample bins is noisy with few samples [1]. I would definitely want to see confidence intervals and statistical tests.
- Results are hard to read. Tables 1 and 2 are difficult to read at a glance. The large number of metrics and the inconsistency in what is reported across tables makes comparisons tedious. I would focus on the most important metrics and avoid reporting all MAS combinations in the main tables since those are handled in the ablation.
- No data or code. The checklist claims both are accessible but neither was attached to the submission as far as I can see. Without it the submission cannot be accepted.
Overall assessment. While the idea is nice, I think the reliance on shaky theory does the paper a disservice. Focusing only on empirical results and properly presenting them with sufficient and well argued experiments would be a much better approach IMO. The claimed interpretability of is also questionable as its inputs and come from black-box LLMs and are effectively tokens rather than real probabilities. This undermines the interpretability of the downstream ML model and makes the promise of "Calibrating Agentic LLMs" overstated.
[1] Roelofs, Rebecca, et al. "Mitigating bias in calibration error estimation." International Conference on Artificial Intelligence and Statistics. PMLR, 2022.
Questions
- Loss / model : Did you implement a custom objective for inside XGBoost, or are the reported numbers produced by XGBoost's native cross-entropy/MSE? Please describe the exact training procedure.
- Theorem assumptions: For Theorems 1–3, can you provide empirical evidence for the key assumptions: the discrimination-ordering assumption (Theorem 1), the sufficiency/Causal-Markov-Blanket property of (Theorem 2), and the non-adversarial, outcome-informative soft targets (Theorem 3)?
- Covariate stability: How do you ensure has a consistent structure across instances within a task at inference time? What happens when the specialist agent omits or hallucinates a feature?
- Probability derivation: Can you justify deriving probabilities by binning binary decisions?
- Datasets and reproducibility: Will you release the data and code?
Limitations
No limitations given by the authors. If they cannot address the above comments / weaknesses then those should be included as limitations.
Final justification
I find the current version of the paper promised by the author's to deviate a good amount from the original paper and is thus hard to evaluate for its suitability. I will update my score to a 3 as many of my points have been addressed though I understand if the AC considers the original points to be fully rebutted and thus worthy of a higher score / acceptance.
Most of my empirical objections have been resolved and the theoretical claims have been narrowed. I still have slight misgivings about the implemented specialist representation satisfying the Theorem 2's sufficiency premise and that XGBoost is just empirically justified in theorem 3. If the paper is accepted I highly recommend the author's commit to framing the theory as motivation and reframing the paper as an empirical paper.
Formatting concerns
None
14 comments
Rebuttal
We are grateful for your constructive questions and comments. We have clarified every point and incorporated the discussion into the revised manuscript; longer numerical tables are provided in a follow-up comment. We have added the discussion into the paper and we would be pleased to clarify any remaining concern in a new comment.
W1. Presentation: The paper is dense and the main conceptual contribution is difficult to identify.
The central problem is not calibration of internal token probabilities. It is calibration of the final patient-level probability produced by an agentic clinical-prediction pipeline. A system may rank patients reasonably well while producing probabilities that are systematically too high, too low, or too extreme; these probabilities are difficult to use for thresholded clinical decisions. Our contribution is to make that final probability the explicit learning and evaluation target.
The method can be read as six concrete steps:
- A frozen homogeneous-parallel branch uses multiple agents with the same task definition and produces a continuous branch probability .
- Frozen task-specialist agents have predefined clinical responsibilities. They extract the fixed task-relevant feature vector and produce a specialist branch probability .
- Patient IDs align the two frozen branch outputs with structured covariates available at the task-specific prediction time.
- An explicit task-level allowlist constructs a fixed, auditable downstream feature vector; labels, annotation/adjudication fields, outcomes, post-index fields, identifiers, and split metadata cannot enter it.
- Only the downstream XGBoost model is trained. Its custom objective combines cross-entropy against the observed outcome, patient-level Brier loss, and two KL terms referencing the continuous branch probabilities.
- The resulting probability is evaluated separately for discrimination, probability accuracy, calibration, uncertainty, prompt sensitivity, subgroup behavior, extraction quality, ablation, and efficiency.
This leads to four conceptual contributions. First, we formulate calibration at the level of the complete agentic clinical-prediction system rather than assuming that good reasoning or discrimination automatically yields usable probabilities. Second, we combine two complementary frozen views: repeated homogeneous inference, which can reduce idiosyncratic decoding variation, and task-specialist extraction, which exposes predefined knowledge-based clinical indicators. Third, we provide a lightweight downstream alignment mechanism that can be audited and trained without modifying the LLM backbones. Fourth, we evaluate the framework across diagnosis, phenotyping, readmission, and independent-hospital mortality rather than on one endpoint or one LLM.
The theoretical analysis is intended to state the conditions under which these design choices are motivated. It is not the sole evidence for the method and does not claim universal dominance of parallel agents, perfect extraction, or guaranteed value from every soft target. The empirical analyses test whether the relevant conditions are approximately supported in the evaluated tasks. This paper focuses on how to improve calibration given comparable discrimination performance.
W2/Q2. Theory
Theorem 1: The theorem is not meant to assert that a parallel architecture always has better discrimination or better overall clinical reasoning. A sequential chain can be beneficial because later agents can use earlier reasoning, refine an intermediate answer, and represent dependencies that independent parallel agents do not capture. The same dependency can also propagate an early omission, hallucination, or overconfident probability through the remaining chain. Parallel agents avoid direct error propagation, but their outputs can lose useful interaction and may still share correlated errors.
The theoretical statement therefore conditions on a restricted comparison: the two systems must have comparable deterministic discrimination signal, and the parallel decoding errors must not be perfectly correlated. Under that condition, averaging the parallel predictions reduces the variance contributed by the non-shared error component. This is a statement about probability stability after controlling the discrimination regime; it is not a proof that parallel inference necessarily has a higher AUROC.
The empirical evidence is correspondingly conditional. We compare AUROC, AUPRC, and P@S95 before interpreting Brier score and ECE. In ADRD, Readmission-IV, and Readmission-III comparisons in Table 1, the relevant sequential and parallel variants have broadly similar discrimination while the parallel variants show lower Brier score/ECE. These cases are consistent with the theorem's motivating regime. The complete table also retains cases in which the pattern is weaker or does not hold. We do not discard those cases or use the theorem to override them. Conversely, a method with a low ECE but substantially degraded discrimination—for example, some MAS_calibration settings—does not demonstrate a useful overall improvement merely because one calibration statistic is smaller.
Theorem 2: The formal object is , an idealized summary containing the task-relevant clinical information from the permitted original input. The Markov-blanket/sufficiency statement belongs to this idealized object. It explains why a knowledge-oriented task summary can, in principle, preserve relevant information while removing irrelevant variation. The implemented is an LLM-derived approximation to ; it is not assumed to be an oracle and is not claimed to satisfy a perfect causal Markov-blanket property patient by patient.
The connection between the formal and implemented objects is evaluated empirically in two ways. First, physician review measures whether predefined specialist indicators are omitted or asserted without evidence. The aggregate omission and hallucination rates are approximately 0.6% and 0.7%, showing that is a close but imperfect operational proxy for the requested task summary. Second, the ablation removes those features while holding the remaining system fixed; the observed deterioration shows that the extracted features contribute predictive information on the evaluated tasks. These results support informativeness of the proxy.
Physicians' diagnoses strictly follow the original inputs and are inherently knowledge-based. In contrast, existing trajectory-based discrimination methods do not rely on this knowledge for their judgments; instead, they perform calibration based on the internal reasoning mechanisms of LLMs. While the advantage of these baselines lies in their generalizability, they forfeit the potential for knowledge-based calibration. Synthesizing the aforementioned data with the results in our paper, it is evident that although the pathway from to is not entirely lossless in terms of information, this knowledge-based calibration still outperforms knowledge-free calibration in clinical prediction tasks.
Theorem 3: This assumption is necessary and falsifiable. If or is systematically wrong, adversarial, or severely overconfident, forcing the final predictor toward it through a positive KL weight can be harmful. The theorem does not claim otherwise. Its conclusion describes the regime in which the branch targets contain outcome-relevant signal and their errors are not so severe that alignment dominates learning from the hard labels.
We examine that regime using several complementary observations: branch-level discrimination is above chance; specialist extraction has substantially lower omission/hallucination rates than direct LLM reasoning; prompt perturbation quantifies how much the probabilities move under wording changes; and ablations that remove or test whether each target contributes within the complete model. Tables 1 and 3 show that informative cases are much more common than failure cases in the evaluated settings. This supports the assumption on average for these datasets, not for every patient or future distribution.
Rebuttal by Authors (2)
W3.1/Q3. Covariate stability
The specialist branch is organized like a fixed multidisciplinary assessment rather than an open-ended conversation. For each task, the roles are defined in advance, and each role is responsible for a predetermined set of clinically relevant fields. The prompt specifies each field name, its meaning, permitted type/unit, and the JSON schema. Therefore, two patients may have different values or missing evidence, but they do not produce different feature namespaces.
After parsing, the downstream matrix is constructed from an explicit, ordered, task-level allowlist. It contains only (i) legitimate structured covariates available at the prediction index, (ii) predefined specialist features, and (iii) the specialist and parallel probabilities. The training, validation, and test matrices use the same names and order. An unexpected JSON key does not become a new model feature, and an extra numeric column in an intermediate table is ignored unless it is explicitly registered.
The distinction between a missing value and a missing configured feature is important:
- If an expected allowlisted feature is present in the schema but its value for a patient is missing, nonnumeric, or non-finite, it is represented as missing in that fixed position.
- That row-level missing value is imputed using the feature median estimated from the training partition only. The stored training median is reused for validation/test data.
- Zero is only the fallback when every training value for that allowlisted feature is non-finite, so no median can be defined. It is not a second default applied routinely after every median.
- If the entire configured feature column is absent from an input table, construction fails with an error. The system does not silently invent a required column.
- Label, candidate-label, cohort-inclusion, physician annotation, senior adjudication, outcome-derived, post-index, identifier, and split/fold fields are forbidden even if a later code edit attempts to add them to the allowlist.
The released feature-policy test injects these high-risk fields and fails if any reaches the matrix. It also verifies that an unregistered extra numeric field cannot alter the selected feature set. This is how structural consistency and target-leakage prevention are enforced at the model boundary.
Malformed JSON, missing requested keys, and API-call failures are counted as distinct failure modes. When no valid value is recovered, the expected field remains missing in the fixed schema; free text is never expanded into unregistered columns. Physician comparison gives aggregate specialist omission and hallucination rates of approximately 0.6% and 0.7%, respectively, compared with approximately 5.7% and 4.9% for direct LLM reasoning.
W3.2/Q4. Probability derivation:
No patient-level probability is derived by binning a binary decision. Every evaluated predictive system directly emits a continuous value in . For patient , the specialist branch returns , the parallel branch returns , and the trained downstream model returns the final probability . The observed clinical outcome is the realized event label. It is used for supervised learning and evaluation, but it is never transformed into the model's probability.
A binary-outcome dataset does not need to contain a separate “true probability” for each individual in order to evaluate probabilistic predictions. Calibration is a population property: among patients assigned probabilities near a value , approximately a proportion should experience the event. The patient-level realized outcome remains binary, while repeated observations across comparable predictions allow the relationship between predicted probability and event frequency to be assessed.
Binning is used only for two descriptive evaluation tools: ECE and reliability diagrams. We sort the already-generated continuous probabilities into ten equal-mass quantile bins. For bin , we calculate
$ \operatorname{conf}(B_m)=\frac{1}{|B_m|}\sum_{i\in B_m}\hat p_i, \qquad \operatorname{acc}(B_m)=\frac{1}{|B_m|}\sum_{i\in B_m}y_i. $
The first quantity is the mean probability that the model had already produced; the second is the empirical event frequency. Their difference estimates local miscalibration. The bin-level frequency does not generate or replace any patient's probability.
The Brier score does not use bins:
$ \operatorname{BS}=\frac{1}{N}\sum_{i=1}^{N}(\hat p_i-y_i)^2. $
It is a proper scoring rule computed directly from each continuous prediction and observed outcome. We use equal-mass rather than equal-width bins for ECE because [1] shows that equal-mass estimators can have lower calibration-error estimation bias in finite samples. We further report 95% confidence intervals and complement ECE with Brier score, calibration intercept, calibration slope, and reliability plots.
Rebuttal by Authors (3)
W3.3. Results presentation:
Regarding the metrics in the main table and the ablation study, we have provided further supplementary explanations in the paper, similar to the following. Furthermore, we have moved the analysis of the impact of certain MAS structures to the ablation study.
The main comparison and the ablation answer different questions. The main comparison asks how complete predictive systems perform. It therefore retains XGBoost, LR, direct LLM, LLM_calibration, MAS_sequential, MAS_parallel, MAS_calibration, and C²Align rather than replacing them with a single unnamed “strong baseline.” The ablation asks what each C²Align component contributes and therefore contains only controlled component removals.
The main presentation now separates discrimination from probability quality/calibration. AUROC is the primary discrimination summary; AUPRC and P@S95 remain available because class imbalance and high-sensitivity operation matter clinically. Brier score is the primary bin-free probability-accuracy metric; ECE, calibration intercept, calibration slope, and reliability diagrams describe calibration from complementary perspectives.
W3.4/Q5. Data and code:
The anonymized code repository is supplied separately to the AC through the permitted Official Comment route. No repository URL is placed in this reviewer response. The release contains cohort-construction logic, prompts and fixed JSON schemas, task-specific feature allowlists, the fail-closed feature-policy module and tests, the callable XGBoost objective, random seeds, dependency specifications, notebook/script entry points, and execution instructions. These materials allow an authorized user with the source data to reconstruct the permitted processing and training pipeline.
The data have different access conditions from the code. Even though the MIMIC-III, MIMIC-IV, and TJH datasets are open-access, we are not permitted to republish them.
Credentialed MIMIC records cannot be republished by the authors; researchers must complete the required data-access process and follow the data-use agreement. Institutional TJH records cannot be publicly redistributed. Completed physician annotation forms may contain restricted record-level information and are also not released as public rows. The repository therefore provides schemas, cohort logic, and aggregate results, but not protected patient records, identifiers, raw notes, credentials, or completed restricted annotations.
Q1. XGBoost implementation:
C²Align uses a callable custom XGBoost objective. The reported values are not generated by optimizing native XGBoost CE/MSE and then evaluating an unrelated formula. For raw margin and , the optimized patient-level objective is
$ \ell_i= \operatorname{CE}(y_i,p_i) +\alpha(p_i-y_i)^2 +\beta_{\mathrm{spe}}D_{\mathrm{KL}}(q_i^{\mathrm{spe}}\Vert p_i) +\beta_{\mathrm{par}}D_{\mathrm{KL}}(q_i^{\mathrm{par}}\Vert p_i). $
The custom function get_custom_xgb_obj_bin_dual_kl receives the raw margins and training labels at every boosting iteration. The two soft targets are aligned to the same training rows by patient ID. The function converts the raw margin to , evaluates the derivative contributions of CE, Brier, specialist KL, and parallel KL, applies the chain rule through the sigmoid, and returns one gradient and one Hessian per training row. XGBClassifier uses those derivatives to choose splits and leaf values in the normal second-order boosting procedure.
All three auxiliary coefficients are 0.05, and a Hessian floor prevents nonpositive or numerically unstable curvature values. Both LLM branches remain frozen; only the downstream trees are learned. Five-fold StratifiedGroupKFold within the training partition is used for model selection, with patients kept intact. After selection, the downstream model is fitted on the full training partition and evaluated once on the untouched test partition. Thus, the observed outcomes drive the hard-label term, the branch probabilities enter as soft targets during training, and the held-out outcomes are used only for final evaluation.
[1] Mitigating Bias in Calibration Error Estimation. Proceedings of the 25th International Conference on Artificial Intelligence and Statistics, PMLR, 2022.
[2] Empowering clinical trial design with agentic intelligence and real-world data. Nature Communications, 2026.
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 2/4
- Clarity
- 2/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- use_inspired
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper studies the calibration of agentic large language models (LLMs) for clinical prediction — whether predicted probabilities reflect true risk, not just whether patients are ranked correctly. The authors give a theoretical analysis arguing that parallel agent structures, clinical task knowledge, and an aligned downstream model each tend to improve calibration, and propose C²Align, a framework that combines a parallel branch of identical agents with a branch of specialist agents and distills both into a lightweight, interpretable machine-learning model via a loss targeting ranking accuracy, calibration, and agreement between the branches. They evaluate it on four benchmarks drawn from two public critical-care databases (MIMIC-III and MIMIC-IV) across several backbones, reporting gains in both discrimination and calibration over machine-learning, single-model, multi-agent, and prior calibration baselines.
Strengths and weaknesses
The problem seems real and well-motivated. A model can rank patients correctly yet report absolute risks that are systematically off, which may mislead treatment or prevention decisions. The paper makes this gap concrete and argues that calibration deserves attention alongside discrimination, which has dominated prior clinical LLM work.
The evaluation also seems reasonably careful. The method is tested across several tasks and backbones, and baselines are rerun in a common setup rather than quoted, which makes the comparison fairer. The theoretical results are generally framed as conditional motivation rather than firm guarantees, which seems appropriate given the assumptions involved.
My main concern is the absence of uncertainty quantification. Results are reported as single point estimates, without confidence intervals or significance testing, on modest test sets. This seems especially relevant for a paper centered on calibration, where the metrics can be unstable on small samples and where some gains over the strongest baseline appear narrow, so it is hard to judge how solid the improvements are.
A related concern is the framing of the gains. Some improvements are stated relative to weaker baselines, while the margin over the most competitive method appears smaller, so the headline may read differently from what the closest comparison supports.
Overall this seems like a well-motivated and reasonably evaluated framework, where the contribution may rest more on the calibration framing and design than on a clearly established accuracy advantage.
Questions
- How robust do the improvements appear once uncertainty is taken into account, especially on the smaller test sets?
- How would the comparison read if the most competitive baseline anchored the main results?
- How do you see well-calibrated agentic predictions being used in practice — at what point in the clinical workflow, and by whom?
Limitations
Yes. Two points seem worth adding briefly: the absence of uncertainty quantification given the modest test-set sizes, and the dependence of the theoretical results on idealized assumptions. On ethics, use of the public databases seems appropriate; the open-access statement could be reconciled with what the submission actually provides.
Final justification
I have updated the contribution type from general to use-inspired. I thank the author for giving quite extensive explanations for their contribution of the work. I have changed my overall assessment from borderline reject to borderline accept accordingly. The authors have well addressed my concerns regarding uncertainty through including confidence intervals for their assessments.
Formatting concerns
None to be disclosed.
3 comments
Rebuttal
Thank you very much for your constructive questions and comments. We have clarified every point and incorporated the discussion into the revised manuscript; longer numerical tables are provided in a follow-up comment. We would be pleased to clarify any remaining concern in a new comment.
W1/Q1. Uncertainty
We have included the following 95% confidence intervals and significance tests, and added two new metrics: Intercept and Slope.
We additionally evaluate in-hospital mortality on the TJH EHR dataset from an independent hospital source. This experiment changes both the institution and the clinical endpoint. XGBoost, LR, LLM, LLM_calibration, MAS_sequential, MAS_parallel, MAS_calibration, and C²Align all receive the same structured variables.
The results demonstrate that the improvements of our method are robust.
W2/Q2. Baseline anchoring
In the submission, all improvement values represent the performance of our method compared to the strongest baseline.
We anchor each headline comparison to the strongest observed alternative for the same task, backbone, and metric, and name that alternative explicitly. “Strongest” is not a single model shared across all columns: lower is better for Brier score and ECE, higher is better for AUROC, and the winning comparator can therefore differ by endpoint and metric. We report the point estimate of both methods, the absolute difference, and the relative difference where the denominator is meaningful. At the same time, the complete table retains XGBoost, LR, LLM, LLM_calibration, MAS_sequential, MAS_parallel, MAS_calibration, and C²Align, so the reader can evaluate the full comparison rather than only the most favorable pair.
For a lower-is-better metric such as Brier score, the absolute improvement is reported as , and the relative reduction divides that quantity by . For a higher-is-better metric such as AUROC, the direction is reversed. We always show the underlying values next to a percentage. This avoids three common sources of exaggeration: choosing a different weak comparator for each claim, using the direction favorable to the proposed method without saying so, or presenting a large relative percentage when the absolute change is small.
Q3. Clinical use
The multi-agent system features a front-end interface that presents calibrated probability values alongside model confidence, structured data, key extractions from unstructured notes, indicators of any missing expected inputs, detailed reasoning steps, and the underlying clinical evidence supporting these metrics.
The system is designed for clinical decision support, not autonomous decision-making. For HF/ADRD, potential users include physicians and trained reviewers evaluating diagnoses or phenotypes from long-term clinical records. By displaying continuous risk estimates together with fixed expert indicators and their source evidence, the interface allows users to verify the rationale behind downstream predictions and reject extractions unsupported by the chart. For readmission, the system is best utilized before finalizing discharge plans; for mortality or care escalation risks, it should be used prior to inpatient reviews and escalation decisions. Medical teams can use these insights to prioritize in-depth chart reviews or existing institutional evaluations.
Follow-up A. Statistical uncertainty and additional calibration metrics
Follow-up A. Statistical uncertainty and additional calibration metrics:
| Model | Architecture | AUROC (95% CI) | BS (95% CI) | ECE (95% CI) | Intercept | Slope |
|---|---|---|---|---|---|---|
| GPT-4o | LLM | .6277[.6034,.6520] | .3610[.3400,.3820] | .3250[.3045,.3455] | -1.100[-2.080,-.675] | .116[-.156,.675] |
| LLM_calibration | .6280[.6037,.6523] | .2417[.2229,.2605] | .1590[.1430,.1750] | -.684[-1.236,-.308] | .434[.109,.934] | |
| MAS_sequential | .6009[.5762,.6256] | .3882[.3668,.4096] | .3473[.3264,.3682] | -2.083[-4.404,-1.299] | .660[.252,1.807] | |
| MAS_parallel | .6426[.6186,.6666] | .2947[.2747,.3147] | .2326[.2141,.2511] | -1.238[-3.099,-1.065] | .285[.166,1.424] | |
| MAS_calibration | .6075[.5829,.6321] | .2241[.2058,.2424] | .1147[.1007,.1287] | -.745[-1.504,-.366] | .595[.262,1.239] | |
| C²Align | .6548[.6310,.6786] | .1921[.1748,.2094] | .0511[.0414,.0608] | -.413[-.688,-.070] | .640[.281,1.103] | |
| Gemini-2.5 | LLM | .5723[.5473,.5973] | .3815[.3602,.4028] | .3435[.3227,.3643] | -.997[-2.147,-.698] | .036[-.112,.509] |
| LLM_calibration | .4344[.4094,.4594] | .2509[.2319,.2699] | .1515[.1358,.1672] | -.626[-1.055,-.317] | .427[.120,.881] | |
| MAS_sequential | .6114[.5869,.6359] | .3938[.3724,.4152] | .3514[.3305,.3723] | -1.683[-2.750,-1.278] | .409[.220,.890] | |
| MAS_parallel | .6019[.5772,.6266] | .3753[.3541,.3965] | .3538[.3328,.3748] | -1.391[-2.643,-1.125] | .308[.164,.938] | |
| MAS_calibration | .5397[.5145,.5649] | .2525[.2335,.2715] | .1052[.0918,.1186] | -.538[-.792,-.226] | .522[.177,.972] | |
| C²Align | .6420[.6180,.6660] | .2029[.1853,.2205] | .1048[.0914,.1182] | -.536[-.789,-.224] | .522[.177,.972] | |
| DeepSeek-V4 | LLM | .6556[.6318,.6794] | .2959[.2759,.3159] | .2601[.2409,.2793] | -.883[-1.532,-.493] | -.017[-.195,.286] |
| LLM_calibration | .6558[.6320,.6796] | .2417[.2229,.2605] | .1499[.1343,.1655] | -.492[-.909,-.136] | .543[.205,.972] | |
| MAS_sequential | .6426[.6186,.6666] | .3155[.2951,.3359] | .2833[.2636,.3030] | -1.038[-1.463,-.973] | .101[.039,.413] | |
| MAS_parallel | .6689[.6454,.6924] | .2626[.2433,.2819] | .1822[.1653,.1991] | -.871[-1.210,-.627] | -.040[-.248,.239] | |
| MAS_calibration | .5547[.5296,.5798] | .2488[.2299,.2677] | .0564[.0463,.0665] | -.317[-.630,.024] | .794[.384,1.279] | |
| C²Align | .6707[.6472,.6942] | .1943[.1770,.2116] | .1005[.0873,.1137] | -.317[-.630,.024] | .794[.384,1.279] | |
| LLaMA-3.1-8B | LLM | .5930[.5682,.6178] | .3075[.2873,.3277] | .2724[.2529,.2919] | -.993[-1.920,-.622] | .045[-.154,.490] |
| LLM_calibration | .5842[.5593,.6091] | .2433[.2245,.2621] | .0997[.0866,.1128] | -.542[-.959,-.202] | .524[.189,.986] | |
| MAS_sequential | .6235[.5991,.6479] | .3330[.3123,.3537] | .3027[.2826,.3228] | -1.601[-2.872,-1.183] | .390[.170,1.037] | |
| MAS_parallel | .5933[.5685,.6181] | .3081[.2879,.3283] | .2455[.2266,.2644] | -1.167[-2.317,-.939] | .184[.027,.867] | |
| MAS_calibration | .4953[.4700,.5206] | .2495[.2305,.2685] | .0689[.0578,.0800] | -.489[-.834,-.157] | .627[.268,1.106] | |
| C²Align | .6483[.6244,.6722] | .1948[.1774,.2122] | .0536[.0437,.0635] | -.422[-.702,-.090] | .652[.281,1.118] |
Follow-up B. Another dataset (TJH EHR dataset)
Follow-up B. Another dataset (TJH EHR dataset):
| Model | Architecture | AUROC | BS | ECE | Intercept | Slope |
|---|---|---|---|---|---|---|
| ChatGPT-4o | LLM | 0.9897[0.9720,1.0000] | 0.0268[0.0026,0.0547] | 0.0351[0.0087,0.0586] | -0.3737[-2.8031,16.7128] | 0.8507[0.6300,12.7724] |
| LLM Calibration | 0.9881[0.9691,1.0000] | 0.0267[0.0022,0.0538] | 0.0426[0.0216,0.0723] | -0.9349[-2.6801,12.9964] | 0.8974[0.6847,6576.7019] | |
| MAS Sequential | 0.9905[0.9732,1.0000] | 0.0269[0.0024,0.0550] | 0.0356[0.0084,0.0588] | -0.3654[-2.2963,224.1730] | 0.8425[0.6415,60.4672] | |
| MAS Parallel | 0.9897[0.9720,1.0000] | 0.0269[0.0025,0.0552] | 0.0353[0.0084,0.0588] | -0.3746[-2.9506,17.1000] | 0.8425[0.6299,11.9594] | |
| Parallel Calibration | 0.9897[0.9725,1.0000] | 0.0266[0.0020,0.0534] | 0.0422[0.0212,0.0697] | -0.9352[-2.8051,14.3941] | 0.9671[0.7125,13.6444] | |
| MAS Calibration | 0.9913[0.9746,1.0000] | 0.0263[0.0019,0.0535] | 0.0412[0.0189,0.0683] | -0.8662[-2.6063,952.4681] | 0.9537[0.7140,404.2876] | |
| Ours | 0.9944[0.9830,1.0000] | 0.0242[0.0020,0.0497] | 0.0165[0.0084,0.0503] | -0.3442[-3.4604,21202.2797] | 0.9699[0.7103,14.6667] | |
| Gemini-2.5 | LLM | 0.9937[0.9810,1.0000] | 0.0283[0.0032,0.0591] | 0.0172[0.0080,0.0536] | -0.6016[-10.3289,869.0503] | 0.7926[0.5949,259.5400] |
| LLM Calibration | 0.9913[0.9736,1.0000] | 0.0281[0.0039,0.0586] | 0.0209[0.0151,0.0591] | -0.8582[-11.7212,823.6288] | 0.8799[0.6752,372.4578] | |
| MAS Sequential | 0.9913[0.9760,1.0000] | 0.0301[0.0044,0.0603] | 0.0373[0.0084,0.0591] | -0.4355[-2.3314,141.3325] | 0.7840[0.5996,40.0336] | |
| MAS Parallel | 0.9913[0.9753,1.0000] | 0.0273[0.0016,0.0558] | 0.0346[0.0078,0.0591] | -0.5846[-5.8278,323.2476] | 0.7757[0.5815,84.2831] | |
| Parallel Calibration | 0.9913[0.9747,1.0000] | 0.0266[0.0014,0.0549] | 0.0380[0.0144,0.0621] | -0.8418[-4.5586,4345.1314] | 0.8809[0.6659,1555.2101] | |
| MAS Calibration | 0.9905[0.9730,1.0000] | 0.0287[0.0035,0.0593] | 0.0408[0.0151,0.0626] | -0.7199[-2.6742,7070.3936] | 0.8641[0.6414,2365.7587] | |
| Ours | 0.9960[0.9861,1.0000] | 0.0244[0.0008,0.0503] | 0.0135[0.0076,0.0527] | -1.2337[-1597.3424,749.1636] | 0.9556[0.7417,500.0599] | |
| DeepSeek-V4 | LLM | 0.9905[0.9728,1.0000] | 0.0277[0.0021,0.0578] | 0.0356[0.0085,0.0582] | -0.4702[-2.2598,860.8509] | 0.8115[0.6153,258.9504] |
| LLM Calibration | 0.9889[0.9691,1.0000] | 0.0260[0.0015,0.0536] | 0.0378[0.0160,0.0665] | -0.8212[-2.4471,537.3136] | 0.9224[0.6939,225.2888] | |
| MAS Sequential | 0.9897[0.9714,1.0000] | 0.0260[0.0039,0.0523] | 0.0183[0.0093,0.0561] | -0.8504[-4.9308,109.3606] | 0.8748[0.6182,14.8780] | |
| MAS Parallel | 0.9921[0.9755,1.0000] | 0.0245[0.0015,0.0510] | 0.0159[0.0081,0.0534] | -0.4790[-3.5589,442.0511] | 0.8767[0.6549,168.3304] | |
| Parallel Calibration | 0.9921[0.9755,1.0000] | 0.0240[0.0013,0.0511] | 0.0189[0.0163,0.0584] | -0.8851[-7.7330,11308.7526] | 0.9814[0.7639,6324.1859] | |
| MAS Calibration | 0.9905[0.9736,1.0000] | 0.0249[0.0032,0.0501] | 0.0206[0.0150,0.0576] | -0.4577[-3.3641,16.7314] | 0.9959[0.7075,21.3046] | |
| Ours | 0.9921[0.9768,1.0000] | 0.0239[0.0016,0.0497] | 0.0208[0.0172,0.0604] | -0.1465[-2.2221,22.7149] | 0.9959[0.7399,86.1955] | |
| LLaMA-3.1-8B | LLM | 0.9873[0.9667,1.0000] | 0.0275[0.0022,0.0571] | 0.0241[0.0094,0.0576] | -0.4818[-5.1306,582.2047] | 0.8183[0.6134,177.0876] |
| LLM Calibration | 0.9889[0.9707,1.0000] | 0.0277[0.0036,0.0543] | 0.0658[0.0485,0.0974] | -0.8714[-5.6161,457.9796] | 0.9240[0.6931,204.1377] | |
| MAS Sequential | 0.9865[0.9657,1.0000] | 0.0275[0.0023,0.0566] | 0.0242[0.0094,0.0580] | -1.0047[-536.4076,371.3003] | 0.8338[0.6198,38.4596] | |
| MAS Parallel | 0.9905[0.9738,1.0000] | 0.0276[0.0020,0.0572] | 0.0245[0.0096,0.0584] | -0.4794[-4.1125,260.7996] | 0.8316[0.6221,88.1910] | |
| Parallel Calibration | 0.9881[0.9699,1.0000] | 0.0276[0.0036,0.0541] | 0.0650[0.0478,0.0958] | -0.8874[-5.0322,5222.7593] | 0.9431[0.7141,2631.0134] | |
| MAS Calibration | 0.9889[0.9707,1.0000] | 0.0283[0.0044,0.0554] | 0.0710[0.0532,0.1038] | -0.6813[-2.8815,2679.8643] | 0.9379[0.6877,930.4503] | |
| Ours | 0.9929[0.9770,1.0000] | 0.0238[0.0041,0.0479] | 0.0229[0.0106,0.0574] | -0.3158[-2.2833,129.4068] | 1.0138[0.7753,233.8173] |
- Rating
- 5/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 4/4
- Contribution type
- use_inspired
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper proposes a calibration framework for agentic systems in the clinical preiction domain. This is motivated by the importance of calibration for correctly interpreting outputs of agentic systems as actual event probabilities which is especially important in the clinical domain. The framework, called C^2 Align, claims to provide good discrimination as well as calibration, by using 2 branches:
- Parallel branch - Mulitple parallel agents create a baseline probability distribution. Each agent operates using precise instructions from a common prompt asking it to output a prediction, probability, and reasoning.
- Specialist branch - Multiple specialist subagents are created to extract different parts of the chart (symptoms, medications, etc.), another to interpret and diagnose, and another to review the overall steps. This also outputs a prediction, probability, and reasoning. They then create a multi objective loss consisting of discrimination loss (ability to separate the labels, ie. standard cross entropy), calibration loss (ability to output correct probabilities without overconfidence, ie. brier score) and dual view alignment loss (making sure both branches are considered in the distillation by using KL diveregence of ML model w.r.t both branches). The authors evaluate multiple baselines as well as other calibration methods across metrics measuring both discrimination and calibration. The results show that across tasks, their system performs better across both these types of metrics.
Strengths and weaknesses
Strengths:
- The problem is well defined and the motivation for the method is clearly articulated. The method itself is presented clearly and is easy to follow.
- The baselines are thorough, and the results show consistent improvement, particularly across the calibration metrics.
Weaknesses
- MIMIC is a high-quality dataset, but it draws from a single hospital system. Given the well-documented institutional biases in EHR data, evidence of generalization across multiple hospital systems would considerably strengthen the claims. I acknowledge that procuring such multi-site data is difficult in practice.
- I would also have liked to see the method's sensitivity to prompt formulation addressed. LLM output distributions are known to shift substantially under small prompt perturbations, and since the proposed approach operates on these probabilities, prompt variation could be a meaningful and uncontrolled source of variance in the reported results.
Questions
- Would have liked to see some more details about how the train/test split was created, as there are a few pitfalls for data leakage when it comes to longitudinal EHR data.
Limitations
Yes
Formatting concerns
None
3 comments
Rebuttal
Thank you very much for your constructive questions and comments. We have clarified every point, longer numerical tables are provided in a follow-up comment. We have added the discussion into the paper and we would be pleased to clarify any remaining concern in a new comment.
W1. External validity
We additionally evaluate in-hospital mortality on the TJH EHR dataset from an independent hospital source. This experiment changes both the institution and the clinical endpoint. XGBoost, LR, LLM, LLM_calibration, MAS_sequential, MAS_parallel, MAS_calibration, and C²Align all receive the same structured variables.
W2. Prompt sensitivity
We tested this directly rather than assuming that semantically similar prompts are equivalent. We constructed ten variants that preserve the clinical task, information available to the model, requested variables, output type, and JSON schema while changing paragraph order, wording, and length. Each variant is run through the complete inference, parsing, feature-construction, and prediction pipeline; sensitivity is therefore measured at the final patient-probability level rather than only by comparing sample text responses. We report the across-variant variance and standard deviation of AUROC, Brier score, and ECE.
The controlled elements are important for interpreting this analysis. A prompt variant is not allowed to request a new clinical variable, reveal additional patient information, change the prediction horizon, redefine the outcome, or alter the machine-readable output schema. Those changes would produce a different task rather than a perturbation of wording. The varied elements are the linguistic organization of the same instructions: sentence and paragraph order, synonymous phrasing, degree of explanatory detail, and prompt length. For each architecture, the same patient cohort, frozen split, requested feature set, and downstream evaluation metrics are used across the ten runs. The reported variance is the variance of the ten resulting metric values, and the reported standard deviation is its square root; it is not the within-run confidence interval.
It shows a more specific pattern: C²Align has the lowest Brier-score standard deviation for all four evaluated backbones; it has the lowest or tied-lowest ECE standard deviation for GPT-4o, Gemini-2.5, and LLaMA-3.1-8B, while MAS_calibration is lower for DeepSeek-V4; and AUROC variation is broadly similar across architectures.
Q1. Data splitting
All splitting and cross-validation use subject_id, not admissions, as the grouping unit. The frozen splits contain 730/243 training/test patients for HF, 712/238 for ADRD, and 800/200 for each readmission cohort. Five-fold shuffled stratified group cross-validation is performed only inside the training partition. No row from the held-out test partition is used to select hyperparameters, loss weights, prompts, or probability thresholds, and an explicit patient-ID intersection check must be empty before fitting.
The temporal cutoff is task-specific. For readmission, all model inputs end at discharge from the index hospitalization, and the label is unplanned readmission in the subsequent 30 days; events and fields arising after the index discharge are excluded from predictors. HF and ADRD are retrospective patient-level diagnosis/phenotyping tasks using the available chart and are not described as predicting future disease onset. For those tasks, two physicians label independently and disagreements are adjudicated; annotation and adjudication fields are targets/metadata, never model covariates. Together, patient grouping, training-only model selection, explicit overlap checks, endpoint-specific cutoffs, and exclusion of label/adjudication/post-index metadata address distinct leakage routes.
Follow-up A. Prompt sensitivity
Follow-up A. Prompt sensitivity:
We constructed ten prompt variants that keep the clinical task, available patient information, prediction horizon, requested variables, output type, and JSON schema fixed, while changing paragraph order, synonymous wording, explanatory detail, and length. Every variant passes through the full pipeline. C²Align has the lowest Brier-score standard deviation for all four LLM backbones. Its ECE standard deviation is lowest or tied-lowest for GPT-4o, Gemini-2.5, and LLaMA-3.1-8B, whereas MAS_calibration is lower for DeepSeek-V4. AUROC standard deviations remain close across methods.
| Model | Architecture | AUROC(std) | BS(std) | ECE(std) |
|---|---|---|---|---|
| GPT-4o | LLM | 0.0620 | 0.0536 | 0.0523 |
| LLM_calibration | 0.0620 | 0.0480 | 0.0408 | |
| MAS_sequential | 0.0630 | 0.0546 | 0.0533 | |
| MAS_parallel | 0.0612 | 0.0510 | 0.0472 | |
| MAS_calibration | 0.0628 | 0.0467 | 0.0357 | |
| C²Align | 0.0607 | 0.0441 | 0.0247 | |
| Gemini-2.5 | LLM | 0.0638 | 0.0543 | 0.0531 |
| LLM_calibration | 0.0638 | 0.0485 | 0.0401 | |
| MAS_sequential | 0.0625 | 0.0546 | 0.0533 | |
| MAS_parallel | 0.0630 | 0.0541 | 0.0536 | |
| MAS_calibration | 0.0643 | 0.0485 | 0.0342 | |
| C²Align | 0.0612 | 0.0449 | 0.0342 | |
| DeepSeek-V4 | LLM | 0.0607 | 0.0510 | 0.0490 |
| LLM_calibration | 0.0607 | 0.0480 | 0.0398 | |
| MAS_sequential | 0.0612 | 0.0520 | 0.0503 | |
| MAS_parallel | 0.0600 | 0.0492 | 0.0431 | |
| MAS_calibration | 0.0640 | 0.0482 | 0.0258 | |
| C²Align | 0.0600 | 0.0441 | 0.0337 | |
| LLaMA-3.1-8B | LLM | 0.0633 | 0.0515 | 0.0497 |
| LLM_calibration | 0.0635 | 0.0480 | 0.0334 | |
| MAS_sequential | 0.0622 | 0.0528 | 0.0513 | |
| MAS_parallel | 0.0633 | 0.0515 | 0.0482 | |
| MAS_calibration | 0.0645 | 0.0485 | 0.0283 | |
| C²Align | 0.0610 | 0.0444 | 0.0253 |
Follow-up B. Another dataset (TJH EHR dataset)
Follow-up B. Another dataset (TJH EHR dataset):
| Model | Architecture | AUROC | BS | ECE | Intercept | Slope |
|---|---|---|---|---|---|---|
| ChatGPT-4o | LLM | 0.9897[0.9720,1.0000] | 0.0268[0.0026,0.0547] | 0.0351[0.0087,0.0586] | -0.3737[-2.8031,16.7128] | 0.8507[0.6300,12.7724] |
| LLM Calibration | 0.9881[0.9691,1.0000] | 0.0267[0.0022,0.0538] | 0.0426[0.0216,0.0723] | -0.9349[-2.6801,12.9964] | 0.8974[0.6847,6576.7019] | |
| MAS Sequential | 0.9905[0.9732,1.0000] | 0.0269[0.0024,0.0550] | 0.0356[0.0084,0.0588] | -0.3654[-2.2963,224.1730] | 0.8425[0.6415,60.4672] | |
| MAS Parallel | 0.9897[0.9720,1.0000] | 0.0269[0.0025,0.0552] | 0.0353[0.0084,0.0588] | -0.3746[-2.9506,17.1000] | 0.8425[0.6299,11.9594] | |
| Parallel Calibration | 0.9897[0.9725,1.0000] | 0.0266[0.0020,0.0534] | 0.0422[0.0212,0.0697] | -0.9352[-2.8051,14.3941] | 0.9671[0.7125,13.6444] | |
| MAS Calibration | 0.9913[0.9746,1.0000] | 0.0263[0.0019,0.0535] | 0.0412[0.0189,0.0683] | -0.8662[-2.6063,952.4681] | 0.9537[0.7140,404.2876] | |
| Ours | 0.9944[0.9830,1.0000] | 0.0242[0.0020,0.0497] | 0.0165[0.0084,0.0503] | -0.3442[-3.4604,21202.2797] | 0.9699[0.7103,14.6667] | |
| Gemini-2.5 | LLM | 0.9937[0.9810,1.0000] | 0.0283[0.0032,0.0591] | 0.0172[0.0080,0.0536] | -0.6016[-10.3289,869.0503] | 0.7926[0.5949,259.5400] |
| LLM Calibration | 0.9913[0.9736,1.0000] | 0.0281[0.0039,0.0586] | 0.0209[0.0151,0.0591] | -0.8582[-11.7212,823.6288] | 0.8799[0.6752,372.4578] | |
| MAS Sequential | 0.9913[0.9760,1.0000] | 0.0301[0.0044,0.0603] | 0.0373[0.0084,0.0591] | -0.4355[-2.3314,141.3325] | 0.7840[0.5996,40.0336] | |
| MAS Parallel | 0.9913[0.9753,1.0000] | 0.0273[0.0016,0.0558] | 0.0346[0.0078,0.0591] | -0.5846[-5.8278,323.2476] | 0.7757[0.5815,84.2831] | |
| Parallel Calibration | 0.9913[0.9747,1.0000] | 0.0266[0.0014,0.0549] | 0.0380[0.0144,0.0621] | -0.8418[-4.5586,4345.1314] | 0.8809[0.6659,1555.2101] | |
| MAS Calibration | 0.9905[0.9730,1.0000] | 0.0287[0.0035,0.0593] | 0.0408[0.0151,0.0626] | -0.7199[-2.6742,7070.3936] | 0.8641[0.6414,2365.7587] | |
| Ours | 0.9960[0.9861,1.0000] | 0.0244[0.0008,0.0503] | 0.0135[0.0076,0.0527] | -1.2337[-1597.3424,749.1636] | 0.9556[0.7417,500.0599] | |
| DeepSeek-V4 | LLM | 0.9905[0.9728,1.0000] | 0.0277[0.0021,0.0578] | 0.0356[0.0085,0.0582] | -0.4702[-2.2598,860.8509] | 0.8115[0.6153,258.9504] |
| LLM Calibration | 0.9889[0.9691,1.0000] | 0.0260[0.0015,0.0536] | 0.0378[0.0160,0.0665] | -0.8212[-2.4471,537.3136] | 0.9224[0.6939,225.2888] | |
| MAS Sequential | 0.9897[0.9714,1.0000] | 0.0260[0.0039,0.0523] | 0.0183[0.0093,0.0561] | -0.8504[-4.9308,109.3606] | 0.8748[0.6182,14.8780] | |
| MAS Parallel | 0.9921[0.9755,1.0000] | 0.0245[0.0015,0.0510] | 0.0159[0.0081,0.0534] | -0.4790[-3.5589,442.0511] | 0.8767[0.6549,168.3304] | |
| Parallel Calibration | 0.9921[0.9755,1.0000] | 0.0240[0.0013,0.0511] | 0.0189[0.0163,0.0584] | -0.8851[-7.7330,11308.7526] | 0.9814[0.7639,6324.1859] | |
| MAS Calibration | 0.9905[0.9736,1.0000] | 0.0249[0.0032,0.0501] | 0.0206[0.0150,0.0576] | -0.4577[-3.3641,16.7314] | 0.9959[0.7075,21.3046] | |
| Ours | 0.9921[0.9768,1.0000] | 0.0239[0.0016,0.0497] | 0.0208[0.0172,0.0604] | -0.1465[-2.2221,22.7149] | 0.9959[0.7399,86.1955] | |
| LLaMA-3.1-8B | LLM | 0.9873[0.9667,1.0000] | 0.0275[0.0022,0.0571] | 0.0241[0.0094,0.0576] | -0.4818[-5.1306,582.2047] | 0.8183[0.6134,177.0876] |
| LLM Calibration | 0.9889[0.9707,1.0000] | 0.0277[0.0036,0.0543] | 0.0658[0.0485,0.0974] | -0.8714[-5.6161,457.9796] | 0.9240[0.6931,204.1377] | |
| MAS Sequential | 0.9865[0.9657,1.0000] | 0.0275[0.0023,0.0566] | 0.0242[0.0094,0.0580] | -1.0047[-536.4076,371.3003] | 0.8338[0.6198,38.4596] | |
| MAS Parallel | 0.9905[0.9738,1.0000] | 0.0276[0.0020,0.0572] | 0.0245[0.0096,0.0584] | -0.4794[-4.1125,260.7996] | 0.8316[0.6221,88.1910] | |
| Parallel Calibration | 0.9881[0.9699,1.0000] | 0.0276[0.0036,0.0541] | 0.0650[0.0478,0.0958] | -0.8874[-5.0322,5222.7593] | 0.9431[0.7141,2631.0134] | |
| MAS Calibration | 0.9889[0.9707,1.0000] | 0.0283[0.0044,0.0554] | 0.0710[0.0532,0.1038] | -0.6813[-2.8815,2679.8643] | 0.9379[0.6877,930.4503] | |
| Ours | 0.9929[0.9770,1.0000] | 0.0238[0.0041,0.0479] | 0.0229[0.0106,0.0574] | -0.3158[-2.2833,129.4068] | 1.0138[0.7753,233.8173] |
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 2/4
- Clarity
- 2/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- use_inspired
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper studies how to improve calibration in agentic LLMs for clinical prediction. It proposes a multi-agent framework that combines LLM outputs and passes them to a downstream machine-learning model. The model is trained with three losses: a discrimination loss, a Brier calibration loss, and an alignment loss. The goal is to make predicted probabilities better match real outcome frequencies while keeping good separation between high-risk and low-risk patients.
Strengths and weaknesses
Strengths
This paper addresses an important and underexplored problem: the calibration of agentic LLMs for clinical prediction. Reliable probability estimates are especially important in healthcare, where overconfident predictions may lead to poor decisions. The problem is meaningful, and the proposed method is reasonably matched to the clinical use case, which is particularly relevant for a use-inspired contribution. It strongly motivates the problem and its proposed solution.
The paper also has several positive aspects. First, it studies both calibration and discrimination rather than reporting only classification performance. Second, the proposed framework combines complementary components: parallel agents for more stable predictions, specialist agents for extracting clinical information, and a supervised ML model for producing the final probability. Third, the experiments cover diagnostic and prognostic tasks using MIMIC datset, and include several LLM backbones, and calibration baselines. Finally, the paper provides the full agent prompts, which helps readers understand the intended workflow.
Weaknesses
The main technical and experimental questions are listed separately in the Questions section. The main weaknesses are:
-
Data-privacy uncertainty: The paper evaluates third-party LLM APIs on MIMIC data but does not explain the data-retention, privacy, and security arrangements.
-
Reproducibility: For example, no code repository is provided despite the checklist stating that the code is available.
-
Incomplete experimental protocol: Important details are missing, including patient-level splitting, the cross-validation procedure, exclusion criteria, class prevalence, and the exact prediction time.
-
Limited statistical support: The test sets are small, but the paper reports results without confidence intervals, repeated runs, or significance tests.
-
Unequal baseline comparisons: The proposed method receives structured data, clinical notes, extracted features, and agent probabilities, while the main ML baselines receive only structured features.
-
Limited calibration analysis: The evaluation relies mainly on Brier score and ten-bin ECE. Calibration slope, calibration intercept, uncertainty bands, and subgroup calibration are not reported.
-
Limited external validity: All benchmarks come from MIMIC, and no external hospital, temporal, or prospective validation is provided.
-
Missing efficiency analysis: The framework requires multiple LLM calls per patient, but cost, latency, and token usage are not reported.
Questions
MIMIC Data Usage Agreement
The PhysioNet license says that users must not share restricted data with third parties and must keep the data secure. If an external LLM API is used, the authors should confirm that it follows a Zero Data Retention policy, does not use the data for training, and does not allow human review.
PhysioNet’s policy on using LLMs with MIMIC data: https://physionet.org/news/post/llm-responsible-use
-
How were the MIMIC data protected when using external LLM APIs such as GPT-4o?
-
Did all external APIs use Zero Data Retention, disable model training, and prevent human review of the data?
Overlap Between MIMIC-IV and MIMIC-III
MIMIC-III and MIMIC-IV come from the same hospital and cover overlapping years from 2008 to 2012. They may include some of the same patients or admissions. However, the records are not easy to match because the datasets use different patient IDs and date-shifting methods. Therefore, MIMIC-III and MIMIC-IV should not be treated as fully independent datasets.
-
Did the authors check for patient overlap between the Readmission-III and Readmission-IV cohorts? If so, how was it done?
-
Were all training and test splits done at the patient level rather than the admission level?
-
Was a separate downstream model trained for each prediction task, or were the four benchmarks combined during training?
-
Please test the method on another related dataset to better support the results.
Citation Inconsistency
- Please correct the model-version inconsistency. The experiments mention DeepSeek-V4 in line 260, while the cited reference is for DeepSeek-V3.
Training Pipeline and Reproducibility
The paper uses XGBoost with a loss that combines cross-entropy, Brier loss, and KL loss. However, standard XGBoost does not directly support this three-part loss.
-
How was the custom XGBoost loss implemented and optimized?
-
Please provide the code used to combine the cross-entropy, Brier, and KL losses.
The checklist says that the code is openly available, but the paper does not provide a GitHub link or another repository link.
- Please provide a link to the anonymized code repository.
The appendix does not provide enough details about the training pipeline. It raises questions such as:
-
How many cross-validation folds were used, and how were the folds created?
-
Was cross-validation done at the patient level?
-
Could the same patient appear in both the training and test sets?
In the “Diagnosis and Phenotyping” section, some samples are called “low-quality or unresolved records” and are removed.
-
How were these low-quality or unresolved records identified?
-
How many records were removed from each dataset?
-
Please provide the full exclusion criteria in the appendix or repository.
Additional Analysis
MIMIC provides demographic information, but the paper does not report results for different patient groups.
- Please report calibration and discrimination results by age, race, sex, or other important patient groups.
The pipeline has several LLM stages, but the paper does not evaluate the quality of the earlier stages.
-
What is the extraction accuracy of the specialist LLM agents?
-
How often do the agents produce hallucinations, invalid JSON, or missing values?
-
Were the outputs of the LLM agents compared with human reviewers?
The full method requires several LLM calls for each patient.
-
What is the average token usage and API cost per patient?
-
What is the average processing time per patient?
-
How often do API calls or agent stages fail?
Writing and Presentation
-
Rewrite the method summary on page 3 as a simple numbered workflow. The current paragraph introduces both branches, three losses, soft labels, alignment, and the ML model at once, which makes it difficult to follow.
-
Clearly reference and explain Figure 1 in Section 3.2.
-
Clearly state in Section 3.2 and Figure 1 that the LLM branches are frozen and only the downstream ML model is trained.
-
Enlarge Figure 1(c) or show it as a separate figure. It is currently too small and crowded.
-
Move the legend in Figure 1(c) so that it does not cover the plotted results.
-
Move the legend in Figure 2(c) outside the plotting area.
-
Improve the grouping in Tables 1 and 2. The dashed lines separating the ML, LLM, and MAS groups are too light. Use stronger lines, more spacing, or shaded group labels.
Limitations
yes
Final justification
Most of my concerns have been addressed. However, issues such as the overlap between MIMIC-III and MIMIC-IV remain. Although the authors mention that they have employed an approach in the paper ClinicRealm to address this, the paper does not explain a patient-level linkage or deduplication procedure between MIMIC-III and MIMIC-IV.
Formatting concerns
- The code was not provided, despite the authors stating in the checklist that it was available.
- The limitation section is in the appendix, not the main content of the paper.
5 comments
Rebuttal
Thank you very much for your constructive comments. We have clarified every point and added the discussion into the paper, We are pleased to clarify any remaining concern.
W1/Q1-Q2. Data privacy:
The study was reviewed by the authors' institutional IRB under an approved protocol. To preserve double-blind review, we do not state the institution name or searchable protocol identifier in this response. Model inference was conducted only in institutionally approved, security-controlled environments, including security-tagged local compute and approved enterprise API endpoints such as secure Azure OpenAI services. No consumer-facing chat product was used. The endpoint configurations used for the reported experiments were governed by applicable enterprise terms and institutional controls that prohibit provider training and human review and prevent persistent retention of prompts and outputs. The corresponding privacy and security commitments are added in the manuscript. Only results generated under configurations compatible with the applicable data-use agreement are included.
W2/Q8-Q10. Reproducibility&training
The reported C²Align results are produced by a callable custom XGBoost objective, not by training with XGBoost's native cross-entropy or squared-error objective and then adding Brier/KL values after training. Let be the raw XGBoost margin and the final patient-level probability. For patient , the objective is
$ \ell_i= \operatorname{CE}(y_i,p_i) +\alpha(p_i-y_i)^2 +\beta_{\mathrm{spe}}D_{\mathrm{KL}}(q_i^{\mathrm{spe}}\Vert p_i) +\beta_{\mathrm{par}}D_{\mathrm{KL}}(q_i^{\mathrm{par}}\Vert p_i). $
Here, is the observed binary outcome, is the specialist branch's continuous probability, and is the homogeneous-parallel branch's continuous probability. The CE term fits the hard clinical outcome. The Brier term directly penalizes squared probability error. The two KL terms encourage the downstream probability to remain consistent with the two informative soft targets while still being learned against the observed outcome.
At every boosting iteration, get_custom_xgb_obj_bin_dual_kl computes the analytical first- and second-order derivatives of the complete objective with respect to the raw margin . The callable is passed directly through XGBClassifier(objective=...), so all four terms influence split selection, leaf weights, and tree construction. They are not post-hoc calibration scores. We use and apply a lower bound to the Hessian for numerical stability.
The anonymized repository supplied separately to the AC contains all the details.
W3/Q11-Q13. Data splitting&cross-validation
All splitting uses subject_id as the grouping unit rather than treating admissions or rows as independent samples. The split is performed once at the patient level. An explicit patient-ID intersection check is required to be empty before fitting, so a patient cannot appear in both the training and held-out test partitions.
Q14-Q16. Exclusion criteria
When the two initial reviewers disagreed, a senior physician reviewed the available diagnostic and phenotype evidence. A record was excluded only when the review was incomplete or the available evidence remained genuinely ambiguous or insufficient for a confident reference label after adjudication. HF excluded 27 records and retained 973 adjudicated patients; ADRD excluded 50 and retained 950.
Readmission and TJH in-hospital mortality use observed outcomes rather than adjudicated diagnostic/phenotype labels, so the same ambiguity-based exclusion is not applied to those outcomes. Importantly, annotation status, physician labels, adjudication variables, candidate-code indicators, and cohort-inclusion decisions are metadata used during cohort construction; they are explicitly forbidden from the downstream feature matrix.
Q3-Q6. MIMIC & external evaluation
Within each MIMIC release, the patient-level split and every cross-validation fold are mutually exclusive by subject_id. Across MIMIC-III and MIMIC-IV, however, reliable patient matching is not possible because the releases use different deidentified identifiers and date-shifting procedures. At this point, we followed [1].
Each of the four original benchmarks trains a separate downstream model.
We additionally evaluate in-hospital mortality using the TJH EHR dataset from an independent hospital source.
W4/W6-W7/Q17. Additional analysis
We add 95% confidence intervals for AUROC, Brier score, and ECE, and report calibration intercept and calibration slope in addition to the original metrics.
We also report descriptive AUROC, Brier score, and ECE by age, sex, and race, further demonstrating the effectiveness of our method.
Q18-Q20. Specialist extraction
We compare the requested specialist indicators with physician review. Aggregated across the evaluated tasks and datasets, specialist-agent omission and hallucination rates are approximately 0.6% and 0.7%, respectively. For direct LLM reasoning, the corresponding rates are approximately 5.7% and 4.9%.
Structural consistency is enforced before the downstream model sees the data. Each task fixes the specialist roles, clinical fields, units, output types, and JSON schema. The model matrix is built from an explicit ordered allowlist containing only legitimate index-time structured covariates, predefined specialist features, and the two branch probabilities. Validation and test data use exactly the same feature names and order learned from the training configuration.
To make the missing-value policy exact, the handling is as follows:
- If an allowlisted numeric feature is missing or non-finite for an individual row, it is imputed using that feature's median estimated from the training partition only.
- The stored training median is reused unchanged for validation and test rows; no imputation statistic is recomputed from held-out data.
- Zero is used only when an allowlisted feature is entirely non-finite in the training partition, so a training median does not exist.
- If a feature column required by the configured allowlist is absent from the input table altogether, matrix construction raises an error rather than silently inventing the column.
- Unexpected extra numeric columns are ignored. Label, candidate-label, cohort-inclusion, annotation, adjudication, outcome-derived, post-index, identifier, and split/fold fields are rejected even if accidentally added to the allowlist.
- Malformed JSON, missing requested fields, and API failures are tracked separately. When a valid value is unavailable, the expected field remains missing inside the fixed schema; the system never creates a new column or variable-length vector from unexpected model text.
W8/Q21-Q23. Efficiency
We report average per-patient token use, estimated API cost, and processing latency for the direct LLM, LLM_calibration, MAS_sequential, MAS_parallel, and C²Align configurations of each applicable backbone. These values make the additional computational burden of the complete pipeline visible rather than comparing predictive metrics alone. For context, the table also includes a simple physician-time cost reference based on the stated hourly wage assumption; this is an engineering comparison, not a claim that one automated prediction replaces a physician encounter.
Server load and network variation produce single-attempt API failure rates of approximately 0.005%-0.1% across models and datasets. Retrying allowed the retained experimental runs to complete.
W5. Unequal modality
The original experiments compare complete end-to-end systems, not architectures under identical information access. Conventional ML baselines use the structured covariates adopted in prior clinical-prediction work [1-3].
In our additional TJH mortality experiment, all baselines use the same structured inputs, thereby eliminating the modality imbalance between text and structured data. Nevertheless, the results still demonstrate that C²Align achieves optimal performance.
Q7&Q24-Q30. Writing
The method summary is rewritten as a numbered sequence:
- A frozen homogeneous-parallel branch reads the permitted patient context and returns a continuous prob.
- Frozen task-specialist agents extract a fixed set of task-relevant indicators and produce a specialist prob.
- Outputs from both branches are aligned with structured covariates by patient ID and validated against the task schema.
- The explicit allowlist constructs the fixed downstream feature vector.
- Downstream XGBoost model is trained with the custom loss.
- The final patient-level probability is evaluated for discrimination, probability accuracy, calibration, uncertainty, extraction quality, and efficiency.
Section 3.2 now refers to Figure 1 at the point where each branch is introduced and explicitly marks both LLM branches as frozen. We have also refined details in the figures and tables. The main table emphasizes AUROC as the discrimination and BS/ECE as calibration, while AUPRC, P@S95, intercept/slope, and complete method variants remain available. The ablation table is restricted to component removals so that it answers a different question from the main comparison. Also, we correct the citation of Deepseek-v4 and move limitation to the main text.
[1] ClinicRealm: Re-evaluating Large Language Models with Conventional Machine Learning for Non-Generative Clinical Prediction Tasks. npj Digital Medicine, 2026.
[2] Large language models are less effective at clinical prediction tasks than locally trained machine learning models. Journal of the American Medical Informatics Association, 2025.
[3] Augmented Risk Prediction for Alzheimer’s Onset From Electronic Health Records With Large Language Models. Innovation in Aging, 2025.
Follow-up A & B. Subgroup analysis & Efficiency
Follow-up A. Subgroup analysis:
We report the complete descriptive subgroup analysis for the MIMIC-IV Readmission task below. The table retains every comparator and reports discrimination (AUROC), overall probabilistic accuracy (Brier score; BS), and calibration error (ECE). Higher AUROC is better, whereas lower BS and ECE are better. C²Align obtains the lowest BS and ECE in most subgroups.
| Group | Subgroup | Model | Architecture | AUROC | BS | ECE |
|---|---|---|---|---|---|---|
| Age | 18-49 | XGBoost | 0.6415 | 0.2209 | 0.1214 | |
| LR | 0.6192 | 0.2409 | 0.1464 | |||
| GPT-4o | LLM | 0.5182 | 0.4987 | 0.5424 | ||
| MAS_sequential | 0.5830 | 0.4576 | 0.4841 | |||
| MAS_parallel | 0.5580 | 0.4180 | 0.4520 | |||
| C²Align | 0.6660 | 0.2050 | 0.0720 | |||
| 50-64 | XGBoost | 0.5976 | 0.2639 | 0.2181 | ||
| LR | 0.5753 | 0.2839 | 0.2431 | |||
| GPT-4o | LLM | 0.4947 | 0.5337 | 0.6319 | ||
| MAS_sequential | 0.5990 | 0.5296 | 0.5771 | |||
| MAS_parallel | 0.5740 | 0.4900 | 0.5450 | |||
| C²Align | 0.6030 | 0.2030 | 0.1580 | |||
| 65-74 | XGBoost | 0.6535 | 0.2382 | 0.1766 | ||
| LR | 0.6312 | 0.2582 | 0.2016 | |||
| GPT-4o | LLM | 0.5442 | 0.5077 | 0.5859 | ||
| MAS_sequential | 0.6410 | 0.4896 | 0.5331 | |||
| MAS_parallel | 0.6160 | 0.4500 | 0.5010 | |||
| C²Align | 0.6600 | 0.1910 | 0.1100 | |||
| 75-84 | XGBoost | 0.6975 | 0.2062 | 0.0992 | ||
| LR | 0.6752 | 0.2262 | 0.1242 | |||
| GPT-4o | LLM | 0.5887 | 0.4727 | 0.5139 | ||
| MAS_sequential | 0.7110 | 0.4146 | 0.4241 | |||
| MAS_parallel | 0.6860 | 0.3750 | 0.3920 | |||
| C²Align | 0.6790 | 0.1960 | 0.0750 | |||
| 85+ | XGBoost | 0.6071 | 0.2345 | 0.1519 | ||
| LR | 0.6048 | 0.2545 | 0.1769 | |||
| GPT-4o | LLM | 0.5032 | 0.4957 | 0.5589 | ||
| MAS_sequential | 0.6080 | 0.4486 | 0.4541 | |||
| MAS_parallel | 0.5830 | 0.4090 | 0.4220 | |||
| C²Align | 0.6110 | 0.2080 | 0.1350 | |||
| Sex | F | XGBoost | 0.6001 | 0.2415 | 0.1276 | |
| LR | 0.5778 | 0.2615 | 0.1526 | |||
| GPT-4o | LLM | 0.5032 | 0.5047 | 0.5374 | ||
| MAS_sequential | 0.6160 | 0.4656 | 0.4991 | |||
| MAS_parallel | 0.5910 | 0.4260 | 0.4670 | |||
| C²Align | 0.6030 | 0.2090 | 0.0470 | |||
| M | XGBoost | 0.6708 | 0.2304 | 0.1239 | ||
| LR | 0.6485 | 0.2504 | 0.1489 | |||
| GPT-4o | LLM | 0.5552 | 0.5047 | 0.5634 | ||
| MAS_sequential | 0.6470 | 0.4826 | 0.5121 | |||
| MAS_parallel | 0.6220 | 0.4430 | 0.4800 | |||
| C²Align | 0.6760 | 0.1920 | 0.0860 | |||
| Race | WHITE | XGBoost | 0.6140 | 0.2502 | 0.1436 | |
| LR | 0.5917 | 0.2702 | 0.1686 | |||
| GPT-4o | LLM | 0.5092 | 0.5237 | 0.5814 | ||
| MAS_sequential | 0.6260 | 0.5086 | 0.5531 | |||
| MAS_parallel | 0.6010 | 0.4690 | 0.5210 | |||
| C²Align | 0.6050 | 0.2040 | 0.0810 | |||
| BLACK | XGBoost | 0.6700 | 0.1574 | 0.1131 | ||
| LR | 0.6477 | 0.1774 | 0.1281 | |||
| GPT-4o | LLM | 0.5877 | 0.4087 | 0.5049 | ||
| MAS_sequential | 0.6870 | 0.1876 | 0.1491 | |||
| MAS_parallel | 0.6620 | 0.1480 | 0.1170 | |||
| C²Align | 0.7010 | 0.1950 | 0.1020 | |||
| ASIAN | XGBoost | 0.3550 | 0.2385 | 0.2722 | ||
| LR | 0.3550 | 0.2385 | 0.2972 | |||
| GPT-4o | LLM | 0.2392 | 0.4802 | 0.6484 | ||
| MAS_sequential | 0.3580 | 0.3956 | 0.3821 | |||
| MAS_parallel | 0.3330 | 0.3560 | 0.3500 | |||
| C²Align | 0.3773 | 0.2300 | 0.2660 | |||
| UNKNOWN/OTHER | XGBoost | 0.7906 | 0.2160 | 0.1922 | ||
| LR | 0.7683 | 0.2360 | 0.2172 | |||
| GPT-4o | LLM | 0.7152 | 0.4872 | 0.6004 | ||
| MAS_sequential | 0.7980 | 0.5136 | 0.5791 | |||
| MAS_parallel | 0.7730 | 0.4740 | 0.5470 | |||
| C²Align | 0.8450 | 0.1260 | 0.0930 |
Follow-up B. Efficiency:
The table reports mean per-patient token consumption, estimated API charge under the prices used for the experiment, and measured end-to-end latency in the evaluation environment. The LLM-only, calibrated-LLM, multi-agent, and C²Align rows are therefore separated. Across models and datasets, the observed failure probability for an individual API attempt was approximately 0.005%–0.1%; bounded retries recovered all cases in the reported runs. The physician row is only an order-of-magnitude context based on a one-minute review at a $115/hour wage assumption ($115/60 = $1.9167).
| Model | Architecture | Tokens | Cost | Latency (s) |
|---|---|---|---|---|
| GPT-4o | LLM | 5054.29 | $0.0148 | 1.13 |
| MAS_sequential | 4474.15 | $0.0119 | 2.07 | |
| MAS_parallel | 4516.93 | $0.0121 | 1.17 | |
| C²Align | 9571.21 | $0.0269 | 2.24 | |
| Gemini-2.5 | LLM | 5332.12 | $0.0025 | 6.03 |
| MAS_sequential | 4513.53 | $0.0016 | 13.54 | |
| MAS_parallel | 4580.45 | $0.0017 | 6.06 | |
| C²Align | 9912.57 | $0.0042 | 15.59 | |
| DeepSeek-V4 | LLM | 5103.41 | $0.0016 | 4.62 |
| MAS_sequential | 4486.81 | $0.0013 | 9.56 | |
| MAS_parallel | 4542.40 | $0.0013 | 5.82 | |
| C²Align | 9645.81 | $0.0030 | 9.81 | |
| US physician | - | — | $1.9167 | 60.00 |
Follow-up C. Statistical uncertainty and additional calibration metrics
Follow-up C. Statistical uncertainty and additional calibration metrics:
| Model | Architecture | AUROC (95% CI) | BS (95% CI) | ECE (95% CI) | Intercept | Slope |
|---|---|---|---|---|---|---|
| GPT-4o | LLM | 0.6277[0.6034,0.6520] | 0.3610[0.3400,0.3820] | 0.3250[0.3045,0.3455] | -1.100[-2.080,-0.675] | 0.116[-0.156,0.675] |
| LLM_calibration | 0.6280[0.6037,0.6523] | 0.2417[0.2229,0.2605] | 0.1590[0.1430,0.1750] | -0.684[-1.236,-0.308] | 0.434[0.109,0.934] | |
| MAS_sequential | 0.6009[0.5762,0.6256] | 0.3882[0.3668,0.4096] | 0.3473[0.3264,0.3682] | -2.083[-4.404,-1.299] | 0.640[0.252,1.807] | |
| MAS_parallel | 0.6426[0.6186,0.6666] | 0.2947[0.2747,0.3147] | 0.2326[0.2141,0.2511] | -1.238[-3.099,-1.065] | 0.285[0.166,1.424] | |
| MAS_calibration | 0.6075[0.5829,0.6321] | 0.2241[0.2058,0.2424] | 0.1147[0.1007,0.1287] | -0.745[-1.504,-0.366] | 0.595[0.262,1.239] | |
| C²Align | 0.6548[0.6310,0.6786] | 0.1921[0.1748,0.2094] | 0.0511[0.0414,0.0608] | -0.413[-0.688,-0.070] | 0.660[0.281,1.103] | |
| Gemini-2.5 | LLM | 0.5723[0.5473,0.5973] | 0.3815[0.3602,0.4028] | 0.3435[0.3227,0.3643] | -0.997[-2.147,-0.698] | 0.036[-0.112,0.509] |
| LLM_calibration | 0.4344[0.4094,0.4594] | 0.2509[0.2319,0.2699] | 0.1515[0.1358,0.1672] | -0.626[-1.055,-0.317] | 0.427[0.120,0.881] | |
| MAS_sequential | 0.6114[0.5869,0.6359] | 0.3938[0.3724,0.4152] | 0.3514[0.3305,0.3723] | -1.683[-2.750,-1.278] | 0.409[0.220,0.890] | |
| MAS_parallel | 0.6019[0.5772,0.6266] | 0.3753[0.3541,0.3965] | 0.3538[0.3328,0.3748] | -1.391[-2.643,-1.125] | 0.308[0.164,0.938] | |
| MAS_calibration | 0.5397[0.5145,0.5649] | 0.2525[0.2335,0.2715] | 0.1052[0.0918,0.1186] | -0.538[-0.792,-0.226] | 0.522[0.177,0.972] | |
| C²Align | 0.6420[0.6180,0.6660] | 0.2029[0.1853,0.2205] | 0.1048[0.0914,0.1182] | -0.536[-0.789,-0.224] | 0.522[0.177,0.972] | |
| DeepSeek-V4 | LLM | 0.6556[0.6318,0.6794] | 0.2959[0.2759,0.3159] | 0.2601[0.2409,0.2793] | -0.883[-1.532,-0.493] | -0.017[-0.195,0.286] |
| LLM_calibration | 0.6558[0.6320,0.6796] | 0.2417[0.2229,0.2605] | 0.1499[0.1343,0.1655] | -0.492[-0.909,-0.136] | 0.543[0.205,0.972] | |
| MAS_sequential | 0.6426[0.6186,0.6666] | 0.3155[0.2951,0.3359] | 0.2833[0.2636,0.3030] | -1.038[-1.463,-0.973] | 0.101[0.039,0.413] | |
| MAS_parallel | 0.6689[0.6454,0.6924] | 0.2626[0.2433,0.2819] | 0.1822[0.1653,0.1991] | -0.871[-1.210,-0.627] | -0.040[-0.248,0.239] | |
| MAS_calibration | 0.5547[0.5296,0.5798] | 0.2488[0.2299,0.2677] | 0.0564[0.0463,0.0665] | -0.317[-0.630,0.024] | 0.794[0.384,1.279] | |
| C²Align | 0.6707[0.6472,0.6942] | 0.1943[0.1770,0.2116] | 0.1005[0.0873,0.1137] | -0.317[-0.630,0.024] | 0.794[0.384,1.279] | |
| LLaMA-3.1-8B | LLM | 0.5930[0.5682,0.6178] | 0.3075[0.2873,0.3277] | 0.2724[0.2529,0.2919] | -0.993[-1.920,-0.622] | 0.045[-0.154,0.490] |
| LLM_calibration | 0.5842[0.5593,0.6091] | 0.2433[0.2245,0.2621] | 0.0997[0.0866,0.1128] | -0.542[-0.959,-0.202] | 0.524[0.189,0.986] | |
| MAS_sequential | 0.6235[0.5991,0.6479] | 0.3330[0.3123,0.3537] | 0.3027[0.2826,0.3228] | -1.601[-2.872,-1.183] | 0.390[0.170,1.037] | |
| MAS_parallel | 0.5933[0.5685,0.6181] | 0.3081[0.2879,0.3283] | 0.2455[0.2266,0.2644] | -1.167[-2.317,-0.939] | 0.184[0.027,0.867] | |
| MAS_calibration | 0.4953[0.4700,0.5206] | 0.2495[0.2305,0.2685] | 0.0689[0.0578,0.0800] | -0.489[-0.834,-0.157] | 0.627[0.268,1.106] | |
| C²Align | 0.6483[0.6244,0.6722] | 0.1948[0.1774,0.2122] | 0.0536[0.0437,0.0635] | -0.422[-0.702,-0.090] | 0.652[0.281,1.118] |
- Scope
- Moderate ethical concerns (can likely be resolved) (yellow)
Read ethics review
Ethics review
C²Align is built on MIMIC-III and MIMIC-IV, credentialed real-patient EHR data, which drives its ethical concerns; in my opinion they are moderate, near the serious threshold, since all are fixable in revision. The core issue is a compliance gap: the checklist marks the Code of Ethics, IRB, and licensing items as N/A even though the work uses patient data governed by the PhysioNet Credentialed Health Data Use Agreement, which the paper never cites. Three further points: the DUA bars re-identification and redistribution, so the "open access to data and code = Yes" claim is misleading unless only code and derived non-identifying artifacts are released (MIMIC itself cannot be redistributed); the two-clinician manual annotation has no stated IRB determination; and Broader Impact does not address the concrete risk of a miscalibrated model influencing real treatment decisions. Based on the above concerns I recommend the following fixes: cite the MIMIC/PhysioNet DUA and confirm compliance (credentialed access, no re-identification, no raw-record redistribution), correct the N/A checklist items to accurate answers, clarify that any release is code/derived artifacts only, and document IRB or exemption status. The authors should address these, prioritizing the DUA/licensing and IRB items, before publication.
1 comment
Official comments to Ethics Reviewer 8D9c
Thank you for your constructive comments.
The study was reviewed by the authors' institutional IRB under an approved protocol. To preserve double-blind review, we do not state the institution name or searchable protocol identifier in this response. Model inference was conducted only in institutionally approved, security-controlled environments, including security-tagged local compute and approved enterprise API endpoints such as secure Azure OpenAI services. No consumer-facing chat product was used. The endpoint configurations used for the reported experiments were governed by applicable enterprise terms and institutional controls that prohibit provider training and human review and prevent persistent retention of prompts and outputs. The corresponding privacy and security commitments are added in the manuscript. Only results generated under configurations compatible with the applicable data-use agreement are included.
Furthermore, due to privacy concerns and strict Data Use Agreement restrictions (specifically, datasets such as MIMIC-III, MIMIC-IV, and TJH have access conditions independent of the code, meaning researchers must independently complete the required data access approval process, and the authors are not authorized to republish or publicly distribute raw records or physician annotation forms containing restricted information), the anonymous repository we have released does not include protected patient-level EHR records, credentials, institutional identifiers, or completed restricted annotation forms.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Official comments to AC
We sincerely thank all Area Chairs (ACs) and reviewers for their constructive comments and questions. We have provided detailed responses to all points raised and have included all the requested related experiments. All relevant discussions have also been incorporated into the revised manuscript.
Reviewers 69dK (Q8–Q10) and o6bT (Q5) requested access to implementation details and reproducibility materials. In accordance with the exception that allows authors to provide an anonymous code link via an Official Comment to the ACs, the anonymous repository is available at: https://anonymous.4open.science/r/C2Align_repo-3200/.
The repository contains the cohort construction logic, task prompts with fixed JSON schemas, task-specific feature allowlists, fail-closed feature strategy modules and leakage tests, callable custom objective functions, modified machine learning models, random seeds, dependencies, execution entry points, and instructions for the processing and training pipelines within the permissible scope for reproduction.
Although we strictly adhered to an Institutional Review Board (IRB) approved protocol and conducted model inference solely in rigorously security-controlled environments (including security-tagged local computing resources and enterprise-grade secure API endpoints that strictly prohibit data retention, human review, and vendor training)—commitments we have now explicitly added to the manuscript—the repository does not include protected patient-level EHR records, credentials, institutional identifiers, or completed restricted annotation forms. This is due to privacy concerns and strict Data Use Agreement (DUA) restrictions. Specifically, datasets such as MIMIC-III, MIMIC-IV, and TJH have access conditions independent of the code, meaning researchers must independently complete the requisite data access approval processes, and the authors are strictly prohibited from republishing or publicly distributing the raw records or physician annotation forms containing restricted information.