potentialpaper

Ultra Fast PDE Solving via Physics Guided Few-step Diffusion

Xiangrui Kong, Yueqi Wang, Haoyang Zheng, Weijian Luo, Guang Lin

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

TL;DR. Phys-Instruct distills a pretrained diffusion model into a few-step generator with differentiable physics guidance during training, enabling ultra-fast sampling with lower PDE errors and reusable priors for downstream conditional tasks.

Abstract. Diffusion-based models have demonstrated impressive accuracy and generalization in solving partial differential equations (PDEs). However, their practical utility still suffers from high sampling costs and insufficient physical consistency, mainly due to many-step iterative sampling and insufficient physics guidance. To address these issues, we propose \emph{Phys-Instruct}, a physics-guided distillation framework that compresses a pre-trained diffusion PDE solver into a few-step generator while explicitly enforcing PDE consistency through distillation guidance. We reformulate the training objective as a constrained problem with PDE residual, and derive a score-function identity that leads to a practical physics-guided generator update. Across five PDE benchmarks, Phys-Instruct achieves orders-of-magnitude faster inference while reducing the PDE Error by factors of 2.42.4 to 15.515.5, compared with the corresponding 200-step EDM teachers. Moreover, the resulting unconditional student model functions as a compact prior, enabling efficient and physically consistent inference for various downstream conditional tasks. Our results indicate that Phys-Instruct is an effective and efficient framework for ultra-fast PDE solving powered by generative models.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
26 Apr 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:46 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

The paper proposes Phys-Instruct, which distills a pretrained diffusion PDE solver into a one-/few-step generator while adding differentiable PDE-residual guidance during training. Results on five benchmarks report substantially faster inference, lower residuals, and transfer to conditional forward and inverse tasks.

The paper focuses on the speed–physics trade-off, provides a coherent derivation, and demonstrates strong performance in the low-step regime. The theoretical analysis is also included.

The main concern is that PDE residual alone may not reliably establish solution fidelity, conservation, or uncertainty preservation. The evaluation also lacks sufficient evidence on complex temporal PDEs, higher-resolution settings, sparse/OOD observations, diversity after distillation, and comparisons with the closest recent methods. Thus, these clarifications should be included: (i) a stronger case would require evidence that lower residuals correspond to genuinely accurate physical solutions, (ii) clarification of diversity, robustness, baseline fairness, training cost, and novelty.

Current recommended category: Papers that need clarification.

Final justification

I have read the authors' response and the subsequent discussion. The rebuttal substantially addressed the main concerns raised in my initial meta-review, including the relationship between PDE residual and solution fidelity, diversity and uncertainty after distillation, evaluation on more complex temporal PDEs and sparse/OOD settings, as well as baseline fairness and training cost. The additional experiments and analyses significantly strengthen the empirical support for the proposed framework.

While the methodological novelty remains moderate, I find the combination of physics-guided distillation and few-step generative PDE solving technically meaningful, with strong practical benefits and a thorough evaluation. The remaining concerns do not outweigh these strengths, and I therefore recommend acceptance. I also note the citation-checker flag regarding the incorrect author list for the cited “One-Step Diffusion Distillation through Score Implicit Matching” paper, which should be corrected in the final version.

Area Chair NqvE · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

The paper proposes Phys-Instruct, which distills a pretrained diffusion PDE solver into a one-/few-step generator while adding differentiable PDE-residual guidance during training. Results on five benchmarks report substantially faster inference, lower residuals, and transfer to conditional forward and inverse tasks.

The paper focuses on the speed–physics trade-off, provides a coherent derivation, and demonstrates strong performance in the low-step regime. The theoretical analysis is also included.

The main concern is that PDE residual alone may not reliably establish solution fidelity, conservation, or uncertainty preservation. The evaluation also lacks sufficient evidence on complex temporal PDEs, higher-resolution settings, sparse/OOD observations, diversity after distillation, and comparisons with the closest recent methods. Thus, these clarifications should be included: (i) a stronger case would require evidence that lower residuals correspond to genuinely accurate physical solutions, (ii) clarification of diversity, robustness, baseline fairness, training cost, and novelty.

Current recommended category: Papers that need clarification.

Final justification

I have read the authors' response and the subsequent discussion. The rebuttal substantially addressed the main concerns raised in my initial meta-review, including the relationship between PDE residual and solution fidelity, diversity and uncertainty after distillation, evaluation on more complex temporal PDEs and sparse/OOD settings, as well as baseline fairness and training cost. The additional experiments and analyses significantly strengthen the empirical support for the proposed framework.

While the methodological novelty remains moderate, I find the combination of physics-guided distillation and few-step generative PDE solving technically meaningful, with strong practical benefits and a thorough evaluation. The remaining concerns do not outweigh these strengths, and I therefore recommend acceptance. I also note the citation-checker flag regarding the incorrect author list for the cited “One-Step Diffusion Distillation through Score Implicit Matching” paper, which should be corrected in the final version.

1 comment
Authors · CommentOpenReview ↗

Dear Area Chair,

Thank you for the careful meta-review. For ease of review, we summarize below how each concern is addressed in the reviewer responses, without repeating the full protocols and tables.

1. Do lower PDE errors correspond to solution fidelity & improved conservation?

Our additional evaluations provide direct evidence that, on the tested benchmarks, lower PDE errors are accompanied by improved solution accuracy, conservation diagnostics, or independently evaluated physical consistency.

On Poisson, Phys-Instruct-4step improves a held-out fourth-order residual together with independently re-solved L2L^2 and H1H^1 errors over teacher 200 step. Burgers further shows improved mass and viscous energy-balance defects, while the new Kolmogorov experiment shows lower independently dealiased spectral residuals and improved spectrum structure.

These results show that the improvement is not limited to the residual formula used during training. We do not claim residual and solution error are universally equivalent.

See: Reviewer nE2R [1/2], Sec. 1; Reviewer KTwv [2/4], Sec. 4; Reviewer obxi [1/3], Sec. 2.

2. Are diversity and uncertainty preserved after distillation?

The new k=1,2,4,8k=1,2,4,8 Burgers analysis shows that 1-step distillation causes measurable contraction in distribution and sample diversity, but most of this gap is recovered by k=2k=2–44. We report a controllable compute-quality-diversity trade-off rather than claiming lossless distillation. For downstream UQ under 5% partial Poisson observations, Phys-Instruct-1 achieves 89.08% coverage for a nominal 90% interval, indicating that the 1-step conditional model retains useful predictive uncertainty without severe over-concentration.

See: Reviewer KTwv [1/4], Secs. 1–2; Reviewer nE2R [2/2], Sec. 3.

3. What evidence covers temporal dynamics and higher resolutions?

The higher-resolution evidence was already present in the submission: Appendix F.2 provides matched generative comparisons with the corresponding EDM teacher at 1282128^2, 2562256^2, and 5122512^2. To address the temporal-PDE concern, we additionally trained and distilled a Kolmogorov model that evaluates the complete local-in-time vorticity equation. At 8 steps, Phys-Instruct reduces PDE Error and independently evaluated Spectral PDE Error compared to EDM-200.

See: Reviewer nE2R [1/2], Sec. 2; Reviewer KTwv [2/4], Sec. 3.

4. How does the method behave under sparse, corrupted, and OOD inputs?

In addition to the existing sparse-observation Burgers experiment, we added a 2D Poisson task with 5% randomly observed grid points. A single conditional model handles both forward and inverse problems, and Phys-Instruct-1 improves both reference and PDE errors over DiffusionPDE-2000. On Darcy, it remains more accurate under 5% binary permeability-label flips and under a held-out GRF correlation-length shift from ℓ=3.5\ell=3.5 to 5, with each shifted coefficient independently re-solved.

See: Reviewer KTwv [3/4], Secs. 5–6.

5. What is the novelty, and how does Phys-Instruct differ from the closest methods?

Phys-Instruct addresses a specific problem: distilling a pretrained generative model on PDE into a reusable one-/few-step generator while improving equation consistency and removing inference-time PDE correction. Starting from IKL distribution matching, we derive a generator update that combines teacher–student distribution alignment with explicit sample-level PDE guidance. The physics correction is therefore amortized into the student parameters. The generator can be reused as a generative prior for downstream tasks.

This differs from generic Diff-Instruct, which provides the IKL foundation but no PDE guidance; from DiffusionPDE and CoCoGen, which apply physics correction during inference; from PIDM, which trains a physics-informed generative model in one stage rather than distilling an existing prior; and from Yao et al., which uses a function-space prior with iterative inference-time guidance.

See: Reviewer obxi [2/3], Sec. 5-6; Reviewer KTwv [1/4], Sec. 1 and [4/4], Sec. 8.

6. Are the comparisons fair, and what is the training cost?

The main diffusion-based comparisons use the same 54.41M-parameter SongUNet backbone and matched evaluation protocols. Phys-Instruct adds a one-time distillation stage, so we do not claim lower training cost; the benefit is repeated one-/few-step inference without test-time PDE correction.

See: Reviewer obxi [3/3], Sec. 7; Reviewer nE2R [2/2], Sec. 4; Reviewer KTwv [4/4], Sec. 8.

Summary

Overall, the reviewer responses provide the requested evidence and clarifications on solution accuracy, diversity and uncertainty, broader evaluation scope, baseline fairness, training cost, and novelty. We hope these responses address the concerns raised in the meta-review.

Thank you again for your consideration.

Reviewer nE2ROpenReview ↗
Rating
4/6
Confidence
4/5
Quality
3/4
Clarity
2/4
Significance
2/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper introduces Phys-Instruct, a physics-guided distillation framework that compresses general diffusion-based PDE models into one- or few-step generators. By explicitly incorporating PDE constraints during training, the method promotes physically consistent solutions. Experiments on multiple PDE benchmarks demonstrate strong performance in terms of PDE residuals while significantly reducing the number of inference steps. Furthermore, the distilled unconditional model serves as an efficient prior for downstream conditional tasks, including both forward and inverse problems.

Strengths and weaknesses

Strengths:

  • The paper shows a solid and well-motivated mathematical derivation of the IKL-based distributional alignment objective.

  • Phys-Instruct shows strong performance across multiple PDE datasets with improvements in both speed and accuracy, showing strong potential in real-time applications in the future.

  • The paper is clearly written and well organized, making the methodology and experimental results easy to understand and follow.

Weaknesses:

  • I have some reservations about relying heavily on the PDE residual as an evaluation metric. Since the residual is inherently tied to the chosen numerical discretization, improvements in this quantity do not necessarily translate to physically more accurate solutions. In particular, models may achieve lower residuals by producing excessively smooth outputs or exploiting properties of the discretization scheme. Additional validation measures, such as enforcing boundary conditions, monitoring conservation laws (e.g., for NS equation), or assessing solution fidelity through other physics-based diagnostics, would help provide a more complete picture of model performance.

  • Although the appendix includes experiments at higher resolutions, the primary results in the main paper are reported only on relatively low-resolution settings (e.g., 32×3232 \times 32 for Darcy Flow and Poisson). Such resolutions are considerably lower than those commonly considered in many practical PDE applications in the field. Comparison with generative baselines on higher-resolution tasks will be appreciated.

  • The paper does not provide an uncertainty analysis for conditional downstream tasks. Such an evaluation would be valuable for assessing whether the distilled model adequately captures the underlying solution distribution. Moreover, the observation that the student model consistently outperforms the teacher model raises questions about the nature of the distillation process. In particular, it is unclear whether the physics-based constraints may be encouraging overly concentrated or over-constrained predictions, potentially reducing output diversity and underrepresenting uncertainty in the learned distribution.

Questions
  • Could the authors provide more details on how the PDE residual is computed? It would also be helpful to clarify what reference residuals and numerical solvers are used in the datasets.

  • The paper compares against several baselines, but it is not entirely clear whether all methods use comparable backbones and model capacities. Could the authors clarify the architectures and training setups used for each method to ensure a fair comparison?

  • How sensitive is the method to the choice of λphys\lambda_{\text{phys}}? Is there a single value that works well across different PDE datasets, or does this hyperparameter require task-specific tuning?

Limitations

The authors discuss the limitations in their Conclusion and Future Work section.

Final justification

The rebuttal addressed most of my concerns and substantially strengthened the empirical evaluation. In particular, I appreciate the additional physical diagnostics, the uncertainty and diversity analyses, the higher-resolution experiments, and the clarifications regarding the evaluation protocol and baseline settings. These additions increase my confidence in the technical soundness and practical effectiveness of the proposed framework.

My remaining reservation is that the rebuttal primarily strengthens the empirical evidence rather than the conceptual contribution, and I still view the methodological novelty as moderate. Nevertheless, I find the paper technically solid and well evaluated, and I maintain my recommendation for acceptance.

Formatting concerns

NA

4 comments
Authors · CommentOpenReview ↗

Response to Reviewer nE2R [2/2]

Response to Reviewer nE2R [2/2]

3. Does the conditional model retain uncertainty, and does distillation reduce diversity? (W3)

We separate downstream predictive uncertainty from the direct distributional effect of unconditional distillation.

Downstream UQ. We evaluate 10 held-out Poisson-forward cases under identical partial 5% observations, draw 50 conditional samples per case, and compute metrics only at unobserved locations.

Method Steps CRPS ↓\downarrow Empirical 90% coverage
DiffusionPDE 2000 0.0080 92.84%
Phys-Instruct (ours) 1 0.0066 89.08%

Phys-Instruct achieves lower CRPS, while its coverage remains close to the nominal 90% level. Thus, the final one-step conditional model retains useful predictive uncertainty and does not show severe over concentration in this test. We do not claim exact posterior recovery.

This is an end-to-end conditional UQ comparison rather than an isolated distillation experiment: DiffusionPDE uses inference-time DPS, whereas Phys-Instruct uses a trained conditional branch on the distilled backbone.

Direct effect of distillation. On unconditional Burgers generation, SWD measures discrepancy from held-out data, kNN Recall measures support coverage, and Diversity/T200 measures sample-to-sample variation relative to EDM-200.

Model kk PDE Error ↓\downarrow SWD ↓\downarrow Recall ↑\uparrow Diversity/T200 (→1)(\to1)
Phys-Instruct (ours) 1 0.171 0.071 0.674 0.658
-- 2 0.118 0.060 0.830 0.896
-- 4 0.055 0.049 0.930 0.890
-- 8 0.046 0.046 0.919 0.905
EDM 200 0.860 0.043 0.980 1.000

Phys-Instruct is not pure teacher imitation: The IKL term aligns the student with the teacher distribution, while PDE guidance adds a sample-level equation-consistency objective during distillation. The student can therefore achieve lower PDE Error than the teacher without being expected to reproduce the teacher exactly.

At 1 step, the distillation produces measurable contraction in support and spread. Most of this gap is recovered by k=2k=2–44: at k=4k=4, recall reaches 0.930, Diversity/T200 reaches 0.890, and SWD approaches EDM-200 (0.049 versus 0.043), while PDE Error remains much lower (0.055 versus 0.860). Thus, the student’s advantage is metric-specific: physics guidance improves equation consistency, while the distributional cost of aggressive compression is largely recovered with a modest step budget. The results do not indicate that the lower PDE Error is obtained through severe distribution collapse.

4. Are backbone capacity and evaluation protocols comparable across methods? (Q2)

Yes, EDM, DiffusionPDE, CoCoGen, PIDM, and Phys-Instruct use the same 54.41M-parameter SongUNet backbone. The Phys-Instruct teacher, student, and training-only auxiliary each use this architecture; downstream conditional tasks additionally train a 22.44M control branch.

DiffusionPDE applies DPS at inference; CoCoGen adds inference-time refinement based on DiffusionPDE; PIDM incorporates physics during training using the same benchmark-specific residual evaluator as Phys-Instruct; Phys-Instruct incorporates physics during distillation with EDM as the teacher. We use released or official checkpoints from DiffusionPDE [1] paper where applicable. All paired comparisons use the same test instances, conditioning inputs, and metric implementations. We will make these protocol differences and capacity controls more explicit.

5. How sensitive is Phys-Instruct to λphys\lambda_{\mathrm{phys}}, and is one value used across PDEs? (Q3)

λphys\lambda_{\mathrm{phys}} is task-specific, but training is reasonably robust once its scale is chosen appropriately. We use 5×10−35\times10^{-3} for Darcy, 10−210^{-2} for Poisson and Navier–Stokes, 10−310^{-3} for Helmholtz and Burgers, and 10−410^{-4} for Kolmogorov. A universal value is not appropriate because the operators, normalization, discretization, and gradient scales differ across tasks.

Appendix G.1 reports the full Darcy ablation and a practical tuning procedure. We did not perform a full sweep for every PDE, but all reported task-specific weights trained stably. In practice, we use a short warm-up run to ensure that the physics update is neither negligible nor dominant relative to distribution matching, followed by only a small local adjustment if necessary.

Conclusion

These added checks corroborate the original evaluation across independent solvers, higher resolutions, downstream UQ, and unconditional diversity. We will make the residual definitions, higher-resolution evidence, baseline protocols, and claim boundaries more explicit in the revision.

References

[1] DiffusionPDE, NeurIPS 2024

Authors · CommentOpenReview ↗

Response to Reviewer nE2R [1/2]

Response to Reviewer nE2R [1/2]

We thank the reviewer for the careful and constructive assessment and for recognizing the mathematical derivation, broad PDE evaluation, and strong low-step performance of Phys-Instruct. The main questions concern the scope and implementation of PDE Error, whether the reported gains persist under independent physical checks and higher resolutions, whether conditional uncertainty or unconditional diversity is reduced, and whether the baseline and hyperparameter comparisons are fair. The analyses below broaden and corroborate the original evaluation without changing our central claims.

1. What does PDE Error measure, how is it computed, and do the gains persist under independent physical checks? (W1, Q1)

PDE Error directly measures discrete equation consistency, which is the property targeted by the physics guidance. For the teacher–student evaluation, each generated sample is a new unconditional PDE input–solution pair with no preassigned reference solution. We therefore evaluate the per-sample residual RMS in physical units and average it over generated samples to calculate PDE Error, using the same benchmark-specific evaluator for every method.

Benchmark PDE evaluator Reference-data solver
Darcy Conservative flux-form residual ∇ ⁣⋅(a∇u)+1\nabla\!\cdot(a\nabla u)+1, with harmonic face averaging Sparse variable-coefficient finite-difference elliptic solver; homogeneous Dirichlet boundary
Poisson Δu−a\Delta u-a, using a second-order five-point Laplacian Sparse five-point finite-difference Dirichlet solver
Navier–Stokes Released terminal-state proxy DxωT+DyωTD_x\omega_T+D_y\omega_T Dealiased Fourier pseudo-spectral vorticity solver
Burgers Dtu+uDxu−νDxxuD_tu+uD_xu-\nu D_{xx}u, using centered finite differences with ν=0.01\nu=0.01 Periodic Chebfun spectral solver for the full trajectory
Helmholtz Δu+u−a\Delta u+u-a, using a second-order five-point Laplacian Sparse finite-difference Helmholtz solver

Following the reviewer’s suggestion, we add targeted checks for discretization dependence, excessive smoothing, conservation/balance, and spectral structure.

For Poisson, we independently re-solve every generated forcing and compare the generated solution and gradients with the numerical solution. We also use a held-out fourth-order residual not used during training.

Method Steps Held-out FD4 ↓\downarrow Re-solve L2L^2 ↓\downarrow Re-solve H1H^1 ↓\downarrow
Phys-Instruct (ours) 4 5.763×10−35.763\times10^{-3} 6.742×10−36.742\times10^{-3} 6.487×10−36.487\times10^{-3}
EDM 200 4.228×10−24.228\times10^{-2} 1.253×10−21.253\times10^{-2} 1.509×10−21.509\times10^{-2}

Phys-Instruct-4 reduces the held-out residual by 86%, the re-solve L2L^2 error by 46%, and the re-solve H1H^1 error by 57% compared to EDM-200. The improvement therefore persists under a different discretization and is accompanied by more accurate solution values and gradients.

For Burgers, Phys-Instruct-4 reduces the mass-conservation defect from 1.336×10−21.336\times10^{-2} to 1.193×10−21.193\times10^{-2}, and the viscous energy-balance defect from 2.969×10−12.969\times10^{-1} to 1.016×10−11.016\times10^{-1}, relative to EDM-200.

For the newly added Re=1000Re=1000 Kolmogorov-flow benchmark (as suggested by Reviewer KTwv), at the same 8-step budget, Phys-Instruct reduces PDE Error from 150.2 to 18.86, an independently evaluated dealiased Spectral PDE Error from 106.13 to 17.09, and radial-spectrum mismatch from 1.880 to 0.291. Its PDE and Spectral PDE Errors are also lower than EDM-200 (31.46 and 26.08).

Prescribed Dirichlet values are imposed explicitly and residuals are evaluated only on interior nodes; the flow benchmarks use periodic operators. These targeted checks corroborate the original PDE-Error evaluation: the few-step gains are not confined to the training stencil and are supported by independent solution, balance, boundary, and spectral diagnostics.

2. Are the evaluated resolutions restricted to 32232^2? (W2)

No; the higher-resolution evidence was already included but insufficiently visible. Unconditional Navier–Stokes uses a 64264^2 spatial grid; Burgers uses a 128×128128\times128 space–time grid; and Helmholtz and the main conditional Darcy/Helmholtz tasks use 1282128^2 spatial grids.

Appendix F.2 further evaluates Poisson at 1282128^2, 2562256^2, and 5122512^2 against the corresponding multi-step EDM teacher, providing a matched generative-baseline comparison at every resolution. The student/teacher PDE-Error ratios are 41%, 59%, and 34%, respectively. At 5122512^2, one-step inference requires 317 ms and approximately 3.1 GB on one A100. We will make these results more prominent in the revision.

Reviewer nE2R · CommentOpenReview ↗

Thank you for the detailed rebuttal. The responses address most of my concerns and provide substantial additional experimental evidence. In particular, I appreciate the clarifications on the computation of PDE Error, the added independent physical evaluations, the higher-resolution results, the uncertainty and diversity analyses, and the clarification of the baseline protocols and model capacities. These additions strengthen the empirical evaluation and improve the presentation of the paper. I will take these responses into account when updating my final assessment after the discussion period.

Authors · CommentOpenReview ↗

Thank you very much for your response and consideration. Should any further questions arise before the discussion period concludes, we would be glad to discuss them and do our best to address any remaining concerns.

Reviewer KTwvOpenReview ↗
Rating
3/6
Confidence
4/5
Quality
3/4
Clarity
4/4
Significance
3/4
Originality
2/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

Diffusion models have shown to work really well and generalize well on PDE solving, however they do have high sampling costs and aren’t explicitly physically consistent. This work proposes Phy-Instruct to solve these issues. They propose to reduce the sampling steps via distillation and include physical knowledge within that distillation process. They apply a KL divergence loss between the teacher and students distributions and this is weighted based on previous works. They evaluate on five PDE equations and show lower PDE/relative errors in 4 or less steps.

Strengths and weaknesses

Strengths:

  1. This is an important problem, current sota diffusion models do need high inf sampling steps whic can be super slow. Distillation is a neat/simple way and PDE consistency is also considered here.

  2. The paper is well written and method is explained well. Appendix is well written and detailed.

  3. Distillation helps PhyInstruct to achieve lower errors in just 4 steps as compared to 200-200 steps.

  4. Ablation on when the physics weight hyper-parameter is applied is interesting.

  5. Both unconditional and conditional full observation results are shown.

Weaknesses:

  1. The novelty is limited. Distillation is an existing method, yes using PDE loss to ensure physical consistency is interesting but not entirely new. That said, the paper can benefit with more insights and nuanced discussions which can strengthen the work. For example: what do we lose when we distill the model, do we lose some diversity? or OOD generalization. How does the choice of k impact the distilled model's performance?

  2. Can’t find Navier stokes full forward and inverse results not present? Moreover most of the equations in the paper are simpler ones and static.  It would be good to extend to more complex PDE problems or other equations. For exmaple authors can try the Kolmogorov flow (data can be found in [1]).

  3. Another interesting experiment and test of PDE consistency would be temporal PDEs especially after distillation. A simple way would be to extend their Navier stokes experiment on temporal fields as well, I see they have burgers in the appendix but that is 1d, simple and the model is not really learning temporal aspect there.

  4. Similarly for sparse/partial observations [2,3], the authors claim to be testing and performing well on both full and sparse but the only results for sprase is the 1d burgers which is a simplified version. It would be good to see the performance of the distilled model on sparse or partial observation for both forward and inverse tasks for the different PDE equations. This would really give an idea of the PDE consistecy during inference.

  5. The method’s robustness is not sufficiently tested. Important missing experiments include noisy observations, out-of-distribution PDE coefficients or different Reynolds/viscosity regimes. For example does the distilled model still perform well and better than the teacher if we change the viscosity for the Navier Stokes or the wavenumber for Helmholtz during inference.

  6. The authors emphasize on the model being physically consistent even after not using PDE knowledge during inference, it would be good to analyze the PDE residuals during inference via spectral pde errrors, spectral power maybe. and perhaps also looking at the kurtosis and skewness of the residuals especially that they use L2 norm of the PDE residual, which minimizes it in a smooth way.

  7. The physics-guidance weight and training schedule need more analysis. The paper includes an ablation of physics guidance, but it is limited mainly to Darcy flow, am I right? It is unclear whether the same physics weight works across all PDEs, how sensitive the method is to this choice, and whether a scheduled or adaptive physics weight could improve distillation. Similarly, the choice of step budget (k) and the relationship between teacher sampling steps and student sampling steps are not analyzed deeply. For exmaple how does varying k change results and does step ratio of teacher’s k vs student’s k has any relation to the performance of the student and choice of its step budget?

  8. Most baselines are form 2024. More recent works such as [3] are missing from baselines. [3] seems to have code available and is a recent NeurIPS work.

[1] Shu, D., Li, Z., & Farimani, A. B. (2023). A Physics-informed Diffusion Model for High-fidelity Flow Field Reconstruction. Journal of Computational Physics, 111972. https://github.com/BaratiLab/Diffusion-based-Fluid-Super-resolution

[2] Huang, J., Yang, G., Wang, Z., & Park, J. J. (2024). DiffusionPDE: Generative PDE-solving under partial observation. Advances in Neural Information Processing Systems, 37, 130291-130323.

[3]Yao, J., Mammadov, A., Berner, J., Kerrigan, G., Ye, J. C., Azizzadenesheli, K., & Anandkumar, A. (2026). Guided diffusion sampling on function spaces with applications to pdes. Advances in Neural Information Processing Systems, 38, 127057-127094.

Quality: 3 because I feel some important experiments are still missing to really support all claims (for example: sparse observations, higher dimensional PDEs, or complex PDEs) Originality: 2 mainly because the work is not highly novel, and while that is okay, it would add more value if we had more insights into the work, for example, what do we lose when we distill the model, do we lose some diversity? or OOD generalization. How does the choice of k impact the distilled model's performance?

Questions

Questions:

  1. Can the authors evaluate physical consistency beyond mean PDE residual, for example using spectral PDE error, energy spectra, boundary-condition error, conservation metrics, or residual distribution statistics?
  2. For Navier–Stokes, why is a simplified terminal-time vorticity-gradient surrogate used instead of the full time-dependent residual? Could this miss important temporal dynamics?
  3. How does the method perform under sparse observations for PDEs beyond Burgers? In particular, can it handle sparse forward and inverse problems for Darcy, Poisson, Helmholtz, and Navier–Stokes?
  4. What are the teacher and student model parameter counts, training costs?
  5. Since the method distills a multi-step diffusion teacher into a 1–4 step student, can the authors analyze what is lost during distillation? In particular, does the student lose sample diversity, uncertainty calibration, or OOD generalization compared to the teacher?
  6. How is the student step budget k chosen? Can the authors provide an ablation over k, e.g., 1, 2, 4, 8 steps, and analyze whether there is a systematic trade-off between latency, PDE residual, prediction error, and diversity?
Limitations

Yes

Final justification

Thank you for your responses! I acknowledge the thorough rebuttal done by the authors and all the experiments included during this phase. A lot of my concerns regarding more empirical evidence have been resolved. Finally, I think that the paper is good and I am impressed by the speed improvement in the inference using diffusion models; however, I am still hesitant because of the novelty of this work. Distillation using physics loss right now seems more of an engineering solution than a novel research work. I agree novelty is not the only criterion for acceptance, but in that case, having insights into the method and its various plugs is necessary. While some of those do get answered in the form of ablation experiments, adding something like why physics guidance in teh form of residual works when it work and why it does not work when it does not.

Formatting concerns

No concerns

7 comments
Authors · CommentOpenReview ↗

Response to Reviewer KTwv [4/4]

Response to Reviewer KTwv [4/4]

8. Closest recent work, model size, and training cost (W1, W8; Q4)

Closest recent method. Yao et al. is relevant and already cited, but it uses a function-space diffusion prior with iterative inference-time guidance, whereas Phys-Instruct performs training-time distillation of a fixed-grid pretrained teacher. A controlled comparison would require a matched function-space teacher and representation; otherwise representation, teacher, and sampler would change simultaneously. We will clarify this relationship and identify function-space Phys-Instruct as an extension.

Model size. The teacher and student each use the same 54.41M-parameter SongUNet backbone.

Training cost. Phys-Instruct incurs a one-time distillation overhead; we do not claim lower training cost.

Benchmark EDM pretraining Phys distillation Total
Darcy 689.4 506.9 1196.3
Poisson 689.4 506.9 1196.3
Navier–Stokes 1609.0 1191.1 2800.1

All values are training compute in kTFLOPs. For Burgers and Helmholtz, the pretrained checkpoints were inherited, so the teacher totals are unavailable; the measured distillation costs are 3185.3 and 3364.9 kTFLOPs, respectively.

The intended trade-off is a one-time training overhead for repeated one-/few-step inference without test-time PDE correction and for reuse of the resulting generative prior across downstream tasks.

Conclusion

The additional analyses do more than add benchmarks: they reveal the mechanism and practical behavior of physics-guided distillation. They show what aggressive compression costs in support and diversity, how a modest step budget recovers most of that cost, and how the resulting prior behaves under independent physical audits, complex temporal dynamics, sparse observations, and controlled distribution shifts.

We will incorporate these analyses and discussions into the revision. Together, they clarify and substantiate the originality of Phys-Instruct as a principled physics-guided distribution-matching framework and make its compute–quality–diversity trade-off and scope substantially clearer.

Authors · CommentOpenReview ↗

Response to Reviewer KTwv [3/4]

Response to Reviewer KTwv [3/4]

5. Can Phys-Instruct handle sparse forward/inverse problems beyond Burgers, and does it preserve downstream UQ? (W4; Q3, Q5)

We added a 2D Poisson experiment with 5% randomly observed grid points. The mask and observed values are supplied to one conditional model, which handles forward and inverse problems by changing which field is observed.

Method Steps Forward Rel. Error ↓\downarrow Forward PDE Error ↓\downarrow Inverse Rel. Error ↓\downarrow Inverse PDE Error ↓\downarrow
DiffusionPDE 2000 14.40% 0.339 32.42% 0.0604
Phys-Instruct (ours) 1 12.97% 0.286 26.70% 0.0493

Thus, the one-step model improves both reference and PDE errors on sparse forward and inverse tasks beyond the Burgers setting. We do not claim exhaustive sparse evaluation over every PDE listed by the reviewer.

We also evaluate downstream predictive uncertainty on 10 held-out Poisson-forward cases, drawing 50 samples per condition and scoring only unobserved locations.

Method Steps CRPS ↓\downarrow
DiffusionPDE 2000 0.0080
Phys-Instruct (ours) 1 0.0066

Phys-Instruct achieves lower CRPS and 89.08% empirical coverage for a nominal 90% interval, compared with 92.84% for DiffusionPDE. The final one-step conditional model therefore retains useful predictive uncertainty.

Because the two methods use different conditional mechanisms, this comparison evaluates downstream UQ rather than isolating the effect of distillation alone.

6. Robustness to noisy observations and OOD coefficient statistics (W5; Q5)

We evaluate the Darcy 32×3232\times32 forward problem under two controlled shifts. For noisy setup, we randomly flip 5% of the binary permeability labels (binary label noise). For OOD setup, we shifted the GRF correlation length from ℓ=3.5\ell=3.5 to 5, each shifted coefficient field is independently re-solved to obtain its reference solution.

Setting Phys-Instruct-1 Rel./PDE Error DiffusionPDE-2000 Rel./PDE Error
Clean 0.29% / 0.28 4.61% / 0.53
5% label flips 2.84% / 1.24 9.24% / 1.79
ℓ=5\ell=5 0.94% / 0.42 14.00% / 0.77

Phys-Instruct remains more accurate under both shifts. The ℓ\ell-shift is a valid coefficient-distribution test because the complete coefficient field is still supplied to both methods; only its spatial statistics change. We did not vary viscosity or wavenumber because these are fixed PDE parameters and are not inputs to the current models. Changing them would alter the governing operator without informing Phys-Instruct, and therefore represents a different operator-conditioning problem rather than the controlled robustness test considered here.

7. Is one physics weight used across PDEs, and would different schedules improve training? (W7)

λphys\lambda_{\mathrm{phys}} is task-specific, but training is reasonably robust once its scale is chosen appropriately. We use 5×10−35\times10^{-3} for Darcy, 10−210^{-2} for Poisson and Navier–Stokes, 10−310^{-3} for Helmholtz and Burgers, and 10−410^{-4} for Kolmogorov.

Appendix G.1 reports the full Darcy ablation and a practical tuning procedure. We did not perform a full sweep for every PDE, but all reported task-specific weights trained stably. In practice, we use a short warm-up run to ensure that the physics update is neither negligible nor dominant relative to distribution matching, followed by only a small local adjustment if necessary. Adaptive weighting can be a useful extension, but was not evaluated here.

Authors · CommentOpenReview ↗

Response to Reviewer KTwv [2/4]

Response to Reviewer KTwv [2/4]

3. Can Phys-Instruct handle a complex temporal PDE, and what did the original Navier–Stokes test establish? (W2, W3; Q2)

The original Navier–Stokes benchmark uses only terminal snapshots, whereas the new Kolmogorov experiment evaluates the complete time-dependent vorticity equation locally in time.

The original Navier–Stokes data contain only (ω0,ωT)(\omega_0,\omega_T), so its terminal surrogate does not evaluate temporal evolution or establish full forward/inverse capability. Burgers includes temporal dynamics, but only in one spatial dimension.

We added the reviewer-suggested 2D Re=1000Re=1000 Kolmogorov benchmark. Each trajectory is converted into overlapping three-frame 256×256256\times256 samples. Because no pretrained three-frame model was available, we train an EDM teacher and distill it into an 8-step Phys-Instruct student. Burgers provides the systematic kk-analysis; here k=8k=8 is a representative few-step setting.

At the middle frame, we estimate the temporal derivative from the adjacent frames and evaluate the advection, viscous, forcing, and damping terms pseudo-spectrally. PDE Error is the RMS equation residual used for physics guidance. Spectral PDE Error recomputes the residual with an independent dealiased evaluator. Spectrum mismatch measures the radial-spectrum gap to EDM-200. These are local-in-time diagnostics, not long-horizon rollout tests.

Method Steps PDE Error ↓\downarrow Spectral PDE Error ↓\downarrow Spectrum mismatch ↓\downarrow
EDM sampling 8 150.2 106.13 1.880
Phys-Instruct (ours) 8 18.86 17.09 0.291
EDM sampling 200 31.46 26.08 0 (reference)

Phys-Instruct-8 achieves lower PDE Error and Spectral PDE Error than EDM-200 (18.86/17.09 versus 31.46/26.08). Its spectrum mismatch is also substantially smaller than that of EDM-8 (0.291 versus 1.880). This supports few-step applicability to complex temporal flow.

4. Physical consistency beyond mean PDE residual (PDE Error) (W6; Q1)

The additional checks show that the few-step gains persist under held-out discretizations, independent re-solving or re-integration, conservation and balance metrics, spectral residuals, and spectrum structure.

For unconditional Poisson generation, we independently re-solve every generated forcing and compare the generated solution and gradients with the numerical solution. We also evaluate a held-out fourth-order residual not used during training.

Method Steps Held-out FD4 ↓\downarrow Re-solve L2L^2 ↓\downarrow Re-solve H1H^1 ↓\downarrow
Phys-Instruct (ours) 1 0.0276 0.0268 0.0366
-- 4 0.00576 0.00674 0.00649
EDM 200 0.0423 0.0125 0.0151

The 1-step Phys-Instruct lowers the held-out residual before the independent solution errors are fully recovered. At 4 steps, however, Phys-Instruct improves the held-out residual together with both re-solve errors. This shows that the few-step gain persists under a different discretization and extends to independently evaluated solution values and gradients.

For Burgers, we additionally evaluate an independent spectral residual, mass conservation, viscous energy balance:

Method Steps Spectral residual ↓\downarrow Mass defect ↓\downarrow Energy-balance defect ↓\downarrow
Phys-Instruct (ours) 1 1.136 0.0354 0.1968
-- 4 1.194 0.0119 0.1016
EDM 200 1.630 0.0134 0.2969

Phys-Instruct-4 closely matches EDM-200 in rollout accuracy (0.0300 versus 0.0309) while achieving lower spectral residual, mass defect, and energy-balance defect.

For Kolmogorov, the held-out residual RMS/P95/P99/maximum are 17.09/25.60/61.61/406.30, compared with 106.13/181.08/383.63/2233.96 for EDM-8 and 26.08/41.69/99.73/549.80 for EDM-200. The gain is therefore not limited to the mean residual.

Boundary conditions are all satisfied by construction in the corresponding discretizations. Prescribed Dirichlet values are imposed explicitly and residuals are evaluated only on interior nodes; the flow benchmarks use periodic operators.

These results show that lower PDE Errors are accompanied by improved gradient accuracy and preserved spectral structure, providing no evidence of severe over-smoothing.

Reviewer obxiOpenReview ↗
Rating
5/6
Confidence
3/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper proposes Phys-Instruct, a new model to generate physical simulations with diffusion. The paper focuse on the 2 main problems of diffusion models for solving PDEs : physical consistency and sampling cost. The proposed model is an unconditional generator capable of providing faithfull physical trajectories with a very low latency by reformulating the training loss to incorporate a PDE dedicated term. The model is trained using distillation with a teacher-forcing formulation. Furthermore, the model can serve as backbone for downstream tasks.

Strengths and weaknesses

Strength

  • The paper is supported with a theoretical justification for the reformulation of the loss
  • Several experiments are proposed with comparisons with baselines and ablation on some key components (PDE guidance, and in the appendices, noise levels and others)

Weaknesses

  • I found the paper a bit hard to undersand, especially, how the different modules interact with each others during training and inference.
  • I think a few additional expriment would help fully convince the reader of the benefit of the method and the differences wrt other existing models
  • The claim regarding high fidelity simulation is not fully demonstrated in the experiments. If the PDE residual is well minimized, however, the term fidelity can also refer to high resolution with fine grained details in the littérature. Such setting are not explored in the paper (maybe this is just a terminology issue).
Questions

Questions

  • Is the PDE residual the best metric to evaluate the physical faithfullness ? In my experience there are some cases where a high residual can still show nice predictions and low MSE for instance (which is not the best metric, but still) and inversely ie having low residual but high MSE (for instance some equation can have a residual of 0 by predicting constant solution, but high MSE since it is not the target solution) . Have you observed such behaviors ?
  • A major question I have is regarding the training stability of this model with the PDE residual loss term. Such terms have been shown to highly degrade the stability of the training for many reasons, one of them being the conditioning of the PDE. Have you observe such issue when training your model with the PDE residual term ?
  • Flow Matching models are an extension of Diffusion models that are more stable and have a more efficient sampling. Why not considering such techniques ? Or comparing to these methods ?
  • How about the consistency of the student wrt the number of diffusion steps ? How the student behaves when sampling more than 4 steps ?
  • What is the benefit of using such models wrt other class of methods ? I think more complex architectures than those presented in table 11 and that are more SOTA and work well with fast inference (transformers based models for instance). What would be the benefits of Phys-instruct wrt such methods ?
  • Why not comparing to the method of Luo et al metionned several times in the paper. As it seems to be the closest work, this would highlight the improvement of the proposed method and justify the use of several sampling steps ? (does it correspond to table 7 in the appendices ?)
  • What are the training cost of Phys-Instruct wrt to baselines ? I saw table 4 in the appendices, but I believe a comparison with other methods (expecially as they do not require a pre trainnig stage), is important.
  • Regarding table 1 and the unconditional task, in practice, what would be it purpose ? I believe this could be used for data generation ? How can you retrieve the PDE data (physical coefficient, initial / boudary conditions to build datasets for instance ?

Minor

  • Figure 2 is a bit misleading in my opinion for the reader. It feels like the teacher and auxiliary networks take as input a physical fields (which is not the case based on algorithm 2 in the appendices ?)
  • Why considering a different metric in table 3 for the Darcy PDE ?
Limitations

No limitation section is provided. Some directions for future works are suggested in the conclusion. A more detailed section could be added in the supplementary materials

Final justification

As a conclusion, my opinion on the paper toward acceptance still holds and my concerns have been adressed. With the suggested modifications during the rebuttal by all the reviewers, the paper shows interesting conclusion and a thorough evaluation. It could be the basis for future works to solve the limitations discussed during the rebuttal.

Formatting concerns

None

9 comments
Authors · CommentOpenReview ↗

Response to Reviewer obxi [3/3]

Response to Reviewer obxi [3/3]

7. What is the training cost relative to the baselines? (Q7)

Phys-Instruct incurs a one-time distillation overhead; we do not claim lower training cost. The teacher (EDM), student, and training-only auxiliary use the same SongUNet architecture, with 54.41M parameters each.

DiffusionPDE and CoCoGen use the same pretrained EDM model but add no distillation stage (they conduct PDE correction steps during inference); PIDM is trained in a separate single stage. We therefore report the shared EDM pretraining cost, PIDM training cost, the additional Phys-Instruct distillation cost, and the Phys-Instruct total.

Benchmark EDM PIDM Phys distillation Phys total
Darcy 689.4 1047.3 506.9 1196.3
Poisson 689.4 1047.3 506.9 1196.3
Navier–Stokes 1609.0 2352.4 1191.1 2800.1

All values are training compute in kTFLOPs. Distillation costs approximately 74% of EDM pretraining. Including teacher pretraining, Phys-Instruct costs about 14% more than PIDM on Darcy and Poisson and about 19% more on Navier–Stokes.

For Burgers and Helmholtz, the pretrained EDM checkpoints were inherited, so only the measured distillation costs are available: 3185.3 and 3364.9 kTFLOPs, respectively, compared with PIDM costs of 7406.2 and 7921.6 kTFLOPs. Because the original EDM pretraining costs are unavailable, we do not report incomplete end-to-end Phys-Instruct totals for these two tasks.

The intended trade-off is additional one-time training for repeated one-/few-step inference without test-time PDE correction, while retaining a generative prior that can be reused across unconditional and downstream conditional tasks.

8. What is the practical purpose of unconditional generation, how should “high fidelity” be read, why does Darcy use a different metric, and what limitations will be added? (Q8; W3, M2, L1)

The PDE inputs are generated explicitly as output channels together with the solutions, so they do not need to be reconstructed from the generated solution.

Practical role of unconditional generation. The model jointly generates PDE inputs and solutions, for example, (f,u)(f,u) for Poisson or (a,u)(a,u) for Darcy. The generated pairs can be used as synthetic PDE data. Boundary conditions are fixed by each benchmark definition: prescribed Dirichlet values are imposed explicitly, while the flow benchmarks use periodic boundaries. The independent Poisson re-solve check supports the forward numerical consistency of these generated pairs: Phys-Instruct-4 achieves re-solve L2/H1L^2/H^1 errors of 6.742×10−3/6.487×10−36.742\times10^{-3}/6.487\times10^{-3}. Separately, the learned joint prior can be adapted to downstream forward and inverse tasks.

High-fidelity terminology. (W3) We agree that “high fidelity” can be interpreted as super-resolution or recovery of unresolved fine-scale details. This is not our intended claim. We use the term to describe accurate generation with improved equation consistency at the evaluated resolution. The paper includes resolution-scaling experiments up to 5122512^2, but we do not claim super-resolution; we will revise the wording accordingly.

Darcy metric. (M2) Darcy inverse predicts a binary permeability field, so Table 3 uses an absolute/classification-style error for this discrete output; continuous fields use relative L2L^2 error.

Limitations. We will add a dedicated paragraph stating that aggressive compression can contract the unconditional distribution; the present formulation is fixed-grid and uses task-specific PDE evaluators; general operator-parameter conditioning is not evaluated; and calibrated conditional uncertainty is not theoretically guaranteed.

Conclusion

We will revise Figure 2, clarify the scope of PDE Error and “high fidelity,” and add the stated limitations. The additional analyses further support Phys-Instruct as a reusable few-step generative PDE prior that incorporates physics during training without requiring inference-time correction.

Authors · CommentOpenReview ↗

Response to Reviewer obxi [2/3]

Response to Reviewer obxi [2/3]

4. How does the student behave beyond 4 sampling steps? (Q4)

Phys-Instruct can benefit from more than four steps, provided that the larger budget is included during training. A student trained only up to K=4K=4 cannot simply be run for 8 steps because its transport schedule was not trained for an eight-stage mapping. We therefore additionally train an unconditional Burgers student with maximum budget K=8K=8.

SWD measures discrepancy from held-out Burgers data, recall measures support coverage, and Diversity/T200 measures sample variation relative to EDM-200, where 1 denotes teacher-level diversity.

kk sec/sample PDE Error ↓\downarrow SWD ↓\downarrow Recall ↑\uparrow Diversity/T200 (→1)(\to1)
1 0.012 0.171 0.071 0.674 0.658
2 0.036 0.118 0.060 0.830 0.896
4 0.084 0.055 0.049 0.930 0.890
8 0.225 0.046 0.046 0.919 0.905

Most gains occur from 1 to 4 steps. Increasing from 4 to 8 step further reduces PDE Error from 0.055 to 0.046 and SWD from 0.049 to 0.046, while diversity increases from 0.890 to 0.905; recall remains similar, with a small decrease from 0.930 to 0.919. Thus, 8-step sampling remains effective when explicitly trained, but provides smaller additional gains at higher latency.

5. Why are Flow Matching and transformer backbones not included, and what does Phys-Instruct offer beyond deterministic PDE solvers? (Q3, Q5)

Flow Matching and transformer backbones change different components of the implementation and are not the contribution being isolated here. Flow Matching changes the generative teacher formulation, while a transformer changes the network backbone. We keep the EDM teacher and SongUNet backbone fixed throughout the controlled study.

At the framework level, Phys-Instruct is not restricted to either choice. With a pretrained Flow-Matching teacher, the score-based distribution-alignment component can be replaced by its flow/velocity counterpart while retaining sample-level physics guidance. Likewise, the framework does not rely on SongUNet-specific operations and can use a transformer backbone. Our goal is not to identify the strongest generative PDE architecture, but to show that a given pretrained generative PDE model can be converted into a much faster one-/few-step sampler while improving PDE Error. A controlled comparison would require training a matched Flow-Matching teacher and the corresponding physics-guided student; otherwise the teacher formulation and distillation objective would change simultaneously.

The distinction from the deterministic baselines in Table 11 is more fundamental than inference speed. Deterministic solvers in Table 11 learn task-specific mappings to point predictions. Phys-Instruct instead starts from a generative joint prior over PDE inputs and solutions. After distillation, the prior supports unconditional generation and can be adapted to forward, inverse, and partial-observation tasks while retaining a distribution over possible solutions.

This probabilistic capability is demonstrated by an additional Poisson-forward UQ experiment under 5% partial observations. We evaluate 10 held-out cases, draw 50 conditional samples per case, and score only unobserved locations. The one-step model achieves CRPS 0.0066 and 89.08% empirical coverage for a nominal 90% interval. Table 11 further shows that this generative setup remains accurate on point-prediction tasks. Thus, the broader contribution is a reusable probabilistic PDE prior; fast inference is an important benefit, but not the only distinction from deterministic solvers.

6. What is the difference from Luo et al./Diff-Instruct, and which table gives the controlled comparison? (Q6; W2)

Diff-Instruct provides the IKL distribution-matching foundation; Phys-Instruct integrates sample-level PDE guidance into this objective and supports flexible kk-step unrolling. The resulting student amortizes physics correction into its parameters and requires no PDE guidance at inference.

Eqs. (9)-(10) show this integration explicitly. The most direct controlled comparison is the same-architecture w/o Guidance ablation in Table 2: removing physics guidance increases one-step Darcy PDE Error from 0.315 to 8.75. Appendix Table 7 is instead the resolution-scaling experiment. We will make both the methodological distinction and the correct table reference explicit.

Authors · CommentOpenReview ↗

Response to Reviewer obxi [1/3]

Response to Reviewer obxi [1/3]

We thank the reviewer for the constructive assessment and for recognizing the theoretical foundation and broad empirical evaluation of Phys-Instruct. The questions mainly concern the clarity of the training pipeline, the scope of PDE Error, stability, behavior beyond 4 steps, comparison with other model classes, training cost, and the practical role of the generative prior. We address each point directly below and will revise the presentation, terminology, and limitations accordingly.

1. What does each network receive during training and inference, and how will Figure 2 be corrected? (W1; M1)

The teacher and auxiliary receive the generated-and-noised state xtx_t, not external physical fields. During distillation, z,k→gθ→x0z,k \rightarrow g_\theta \rightarrow x_0, and the forward diffusion maps x0x_0 to xtx_t. The frozen teacher and online auxiliary both receive (xt,t)(x_t,t); the auxiliary is updated by denoising score matching. The generator update combines the stopped score-difference gradient with the PDE gradient evaluated on x0x_0, and the PDE term updates only the generator.

During inference, only the student is used; the teacher, auxiliary, and PDE evaluator are absent. Downstream conditional tasks retain the 1-step backbone and train an added ControlNet branch. Figure 2 did not make these data flows sufficiently clear, and we will revise its arrows and labels.

2. Does lower PDE Error imply lower solution error? (Q1)

Not necessarily; PDE Error and reference-solution error measure different properties, and we report them separately whenever paired targets are available. On the Darcy 32×3232\times32 forward task, their sample-wise association is positive but weak (Pearson r=0.350r=0.350, Spearman ρ=0.291\rho=0.291). We also observe method-level decoupling on Helmholtz: CoCoGen reduces PDE Error from 1.48 to 1.07 relative to DiffusionPDE, while relative prediction error is essentially unchanged (9.70% versus 9.69%). Thus, a lower residual does not necessarily imply a proportional reduction in prediction error.

For unconditional generation, each sample defines a new PDE input–solution pair and has no preassigned target. We therefore added an independent Poisson re-solve audit. At one step, Phys-Instruct has a lower held-out FD4 residual than EDM-200 (2.758×10−22.758\times10^{-2} versus 4.228×10−24.228\times10^{-2}) but higher re-solve L2/H1L^2/H^1 errors (2.680×10−2/3.661×10−22.680\times10^{-2}/3.661\times10^{-2} versus 1.253×10−2/1.509×10−21.253\times10^{-2}/1.509\times10^{-2}), showing that the metrics can decouple under aggressive compression. At four steps, however, Phys-Instruct improves all three metrics and beat teacher: FD4 residual 5.763×10−35.763\times10^{-3}, re-solve L2L^2 6.742×10−36.742\times10^{-3}, and re-solve H1H^1 6.487×10−36.487\times10^{-3}.

PDE Error remains valuable because it directly measures equation consistency and provides a differentiable sample-level signal when paired targets are unavailable. Our conclusions do not infer solution accuracy from residual alone: conditional tasks report both metrics, while unconditional tests independently verifies the generated PDE pairs.

3. Can the physics term destabilize training? (Q2)

Yes, if it is over-weighted; within the tested range, however, training is stable. Phys-Instruct does not optimize the PDE residual alone: the IKL term keeps the student aligned with the frozen teacher distribution, while the physics term reduces equation violations. Instability can arise when the physics update overwhelms this balance.

Appendix G.1 reports that the Darcy model trains stably for λphys∈[10−3,10−2]\lambda_{\mathrm{phys}}\in[10^{-3},10^{-2}], with PDE Errors 0.359, 0.315, and 0.318 at 10−310^{-3}, 5×10−35\times10^{-3}, and 10−210^{-2}. The default 5×10−35\times10^{-3} performs best. Increasing the weight to 5×10−25\times10^{-2} causes divergence, while very small values provide insufficient guidance. Applying guidance from the beginning also performs better than late activation (0.315 versus 0.407); removing guidance gives 8.75.

Stability is further supported by teacher initialization, a frozen teacher, explicit boundary enforcement, benchmark-consistent residual discretization, and a task-scaled physics weight. We do not claim stability for arbitrary weights or PDE conditioning, but the existing ablation identifies a clear practical operating range.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.