potentialpaper

Manifold-Guided Stereo-Monocular Refinement for Endoscopic Stereo Disparity Estimation

Jiewen Yang, Yi Zhong, Bin Pu, Xingbo Dong, Ming Zheng, Qika Lin, Kai He, Xuechen Zhang

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

TL;DR. Manifold-Guided Endoscopic Stereo Disparity Estimation

Abstract. Dense stereo disparity estimation provides the geometric basis for 3D perception in computer-assisted endoscopy. Endoscopic stereo matching is difficult because reliable tissue correspondences often appear next to weak-texture, specular, occluded, or deformed regions within the same frame. Existing stereo and stereo-monocular methods improve cost aggregation or introduce monocular priors, but they often treat monocular guidance as a global feature source or an independently predicted candidate. Without evaluating the local support of the current stereo match during refinement, the update can reinforce corrupted correspondences in ambiguous regions or allow monocular priors to override reliable metric matches. To tackle these problems, we introduce Manifold-Stereo, a reliability-gated latent-flow framework for endoscopic stereo disparity estimation. The method refines a monocular disparity candidate through a conditional latent residual flow on an image-aligned correction space induced by stereo cost-volume geometry, then calibrates the corrected candidate to the current stereo disparity scale. A geometric consistency gate computed from left-right feature alignment regulates the candidate contribution during recurrent refinement, preserving stereo estimates in well-matched regions while supplying monocular context where local matching is ambiguous. Experiments on in-domain SCARED and zero-shot SERV-CT and Hamlyn show strong average disparity accuracy and competitive thresholded outlier rates against recent stereo and endoscopic baselines.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
26 Apr 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 4 reviews · OpenReview

Updated 25 Nov 2026, 03:47 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

This paper proposes a stereo–monocular refinement framework for endoscopic disparity estimation that refines a monocular disparity candidate using a cost-volume-conditioned latent-flow mechanism and adaptively fuses monocular and stereo information through a geometric reliability gate. Reviewers agreed that the problem is important, the overall approach is technically interesting, and the experimental results, particularly the strong zero-shot performance, are promising. However, the main concerns are if the paper justifies its key contributions. In the rebuttal, please focus on explaining the advantages of the proposed manifold formulation and latent-flow refinement relative to simpler alternatives, clarifying the theoretical and empirical rationale for the reliability gate, and providing evidence that the gating mechanism operates as claimed through analyses in challenging regions. Please also clarify terminology and potentially confusing design choices, explain the conditioning used in the refinement process, provide additional details on training protocols and fairness of comparisons, and report computational overhead (time & memory).

Final justification

I have read the authors’ rebuttal and the discussion. The rebuttal addressed most of the concerns raised in my initial meta-review, including clarification of the manifold formulation, additional ablations comparing the proposed refinement to simpler alternatives, computational analysis, and a more detailed discussion of the reliability-gating mechanism. Reviewer YPXv indicated that their concerns were resolved and maintained an Accept recommendation, while Reviewer KxqX stated that most concerns were addressed and retained a borderline score based on a remaining question regarding the monocular-candidate ablation. Reviewer jFq8 maintained concerns regarding the conceptual novelty of the manifold formulation and the justification of the complementary gating strategy. I find that the remaining concerns relate primarily to framing and the strength of theoretical justification rather than methodological correctness or empirical validity. No additional information beyond the written reviews, rebuttal, and reviewer discussion was used in this decision. Therefore, I recommend Accept (poster), while encouraging the authors to moderate the manifold-related claims and further strengthen the analysis of the gating mechanism in the final version.

Area Chair ZnkC · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

This paper proposes a stereo–monocular refinement framework for endoscopic disparity estimation that refines a monocular disparity candidate using a cost-volume-conditioned latent-flow mechanism and adaptively fuses monocular and stereo information through a geometric reliability gate. Reviewers agreed that the problem is important, the overall approach is technically interesting, and the experimental results, particularly the strong zero-shot performance, are promising. However, the main concerns are if the paper justifies its key contributions. In the rebuttal, please focus on explaining the advantages of the proposed manifold formulation and latent-flow refinement relative to simpler alternatives, clarifying the theoretical and empirical rationale for the reliability gate, and providing evidence that the gating mechanism operates as claimed through analyses in challenging regions. Please also clarify terminology and potentially confusing design choices, explain the conditioning used in the refinement process, provide additional details on training protocols and fairness of comparisons, and report computational overhead (time & memory).

Final justification

I have read the authors’ rebuttal and the discussion. The rebuttal addressed most of the concerns raised in my initial meta-review, including clarification of the manifold formulation, additional ablations comparing the proposed refinement to simpler alternatives, computational analysis, and a more detailed discussion of the reliability-gating mechanism. Reviewer YPXv indicated that their concerns were resolved and maintained an Accept recommendation, while Reviewer KxqX stated that most concerns were addressed and retained a borderline score based on a remaining question regarding the monocular-candidate ablation. Reviewer jFq8 maintained concerns regarding the conceptual novelty of the manifold formulation and the justification of the complementary gating strategy. I find that the remaining concerns relate primarily to framing and the strength of theoretical justification rather than methodological correctness or empirical validity. No additional information beyond the written reviews, rebuttal, and reviewer discussion was used in this decision. Therefore, I recommend Accept (poster), while encouraging the authors to moderate the manifold-related claims and further strengthen the analysis of the gating mechanism in the final version.

1 comment
Area Chair ZnkC · CommentOpenReview ↗

Rebuttal discussion

Dear Reviewers

As we approach the end of the author discussion period, I'd appreciate it if you could revisit the authors' rebuttal and update your assessment accordingly. Some of the concerns you initially raised may have been addressed, while others may still require clarification.

To help prepare a fair meta-review, please indicate:

  • Which concerns have been fully addressed.
  • Which concerns remain unresolved or have not been sufficiently answered.
  • Whether the rebuttal has introduced any new issues that should be considered.

Your timely feedback is appreciated and will help ensure a fair evaluation. Thank you!

Best regards Your AC

Reviewer jFq8OpenReview ↗
Rating
3/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
2/4
Originality
2/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This work addresses the challenge of dense stereo disparity estimation in endoscopic scenes, where correspondence reliability varies spatially due to weak texture, specular reflection, occlusion, smoke, and instrument contact. The paper proposes Manifold-Stereo, a stereo-monocular refinement framework for endoscopic disparity estimation. It corrects a monocular disparity candidate in a cost-volume-conditioned latent correction space and uses a geometric consistency gate to regulate the contribution of stereo and monocular candidates during recurrent refinement. Experiments are conducted on SCARED, with zero-shot evaluation on SERV-CT and Hamlyn, showing promising performance.

Strengths and weaknesses

The paper studies an important and practically relevant problem. Endoscopic stereo disparity estimation is challenging because reliable and unreliable matching regions coexist within the same frame. The paper correctly identifies that stereo matching may be reliable in textured regions but unreliable around weak texture, specular highlights, occlusions, smoke, and instrument-contact regions. This problem setting is meaningful for endoscopic 3D perception.

However, I have several concerns about the paper.

  1. The paper emphasize Manifold-Guided and Manifold-Stereo. However, the paper explicitly states that the geometric terminology used in this work is only “local and operational” and does not refer to a global anatomical manifold. Why do the paper still emphasize the notion of manifold?

  2. The claimed manifold in this paper is a local correction space induced by the cost-volume latent state and the residual decoder. What advantage does it have over other related techniques? The authors need to further explain the necessity of introducing the manifold perspective. Moreover, the paper does not provide sufficient theoretical analysis to justify the necessity of this choice.

  3. The paper defines stereo reliability as an exponential function of the left-right feature residual, but this design may not be reliable. First, the authors do not explain why the relationship between feature residual and stereo reliability should follow an exponential decay. Second, even if stereo reliability is low, it does not naturally imply that the monocular candidate is more reliable, since both stereo and monocular predictions may fail in complex regions. Therefore, directly using the complement of stereo confidence as the monocular weight is a strong assumption that lacks sufficient support.

  4. The current experiments mainly verify its effectiveness indirectly by ablation study. The authors do not further present the weight maps generated by the gate, nor do they analyze whether these weights are truly concentrated in specular, weak-texture, occluded, or unreliable matching regions. Therefore, the existing experiments only show that the gate improves the final metrics, but do not prove that it works in the way claimed by the paper. The authors should provide visualizations of the gate weight maps.

  5. The stereo branch adopts a CNN, while the monocular branch adopts a ViT. However, the authors do not explain the reason for this design. Why is CNN more suitable for stereo matching, while ViT is more suitable for monocular candidate generation? In addition, the authors do not provide corresponding backbone ablation experiments.

  6. The paper motivates the method by emphasizing that specular reflection, weak texture, smoke, occlusion, instrument contact, and tissue deformation in endoscopic images can lead to local stereo matching failures. However, the experimental section does not provide clear visual examples of these specific degraded cases, nor does it show how these degradations cause existing methods to produce incorrect disparities.

Questions
  1. Why does the paper emphasize the manifold concept if the proposed geometry is only local and operational rather than a global anatomical manifold?

  2. What indispensable advantage does the proposed local correction space have over standard cost-volume-conditioned residual correction or other refinement techniques?

  3. Why should the relationship between left-right feature residual and stereo reliability follow an exponential decay form?

  4. Why can the complement of stereo confidence be directly used as the monocular candidate weight, given that stereo and monocular predictions may fail simultaneously?

  5. Can the authors provide gate weight-map visualizations to verify whether the gate actually focuses on specular, weak-texture, occluded, or unreliable matching regions?

  6. Why does the stereo branch use CNN while the monocular branch uses ViT? Can the authors provide backbone ablations to justify this design?

Limitations

The paper does not sufficiently discuss the limited theoretical support for the manifold terminology, the heuristic nature of the geometric consistency gate, the possible failure of monocular candidates in the same regions where stereo is unreliable, or the lack of direct visualization for the specific degraded endoscopic scenarios used to motivate the method. The paper also does not report enough analysis of computational cost, backbone dependence, or simple confidence-fusion alternatives. These limitations should be discussed more explicitly.

Final justification

Thank you for the detailed response to my review. The rebuttal further clarifies the meaning of the manifold and provides one-step update and path-regularization ablations to demonstrate the effectiveness of multi-step latent refinement. However, my core concerns still remain. First, the authors mainly show that multi-step residual correction and trajectory constraints improve performance, but this still does not sufficiently explain why the mechanism should be formulated as manifold-guided correction, or what fundamental advantage the manifold formulation provides over conventional residual refinement. Therefore, my main concern regarding the conceptual novelty of the method remains. Second, the rebuttal does not fully resolve the core assumption behind the complementary gate. My original concern about whether low stereo reliability alone is sufficient to justify a higher monocular contribution remains insufficiently addressed. Overall, the rebuttal improves the clarity of the method and strengthens the empirical evidence, but the above core concerns remain. Therefore, I maintain my original rating.

Formatting concerns

No.

4 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We are grateful to the reviewer jFq8 for recognizing the importance and practical relevance of endoscopic stereo disparity estimation. We address the reviewer's concerns point by point below.

 

C1/Q1. Meaning of the manifold formulation

We use manifold for the decoder-induced local correction geometry, not a global anatomical manifold. For each stereo pair, the cost volume induces an image-aligned latent neighborhood around Z0Z_0; the shared vector field traces a trajectory within it, and the decoder maps its endpoint to a disparity residual. This differs from predicting an unconstrained residual directly in pixel-disparity space: both the endpoint and intermediate path are restricted relative to pair-specific stereo geometry. Formally, the decoder Jacobian induces a local metric, and Supplementary Relation to Local Energy Regularization shows that, under locally bounded decoder sensitivity, the discrete latent path penalty bounds the corresponding correction energy up to local constants. The term therefore emphasizes the structured local correction space and its constrained trajectory.

 

C2/Q2. Advantage over a standard residual correction

The proposed update differs from a one-step residual head through its parameter-shared path and explicit trajectory regularization. The controlled results are:

Refinement MAE (mm) ↓ EPE (px) ↓
Full latent refinement 2.53 3.05
One-step update 2.82 3.55
Without path-energy loss 3.09 3.84

The one-step variant uses the same latent encoder, conditioning field, vector field, and decoder, isolating the parameter-shared multi-step path. Its 0.50 px higher EPE shows the benefit over a single residual update, while the no-path-energy result supports trajectory regularization. This analysis is reported in the Ablation Study.

 

C3/Q3. Why exponential decay for stereo reliability?

The exponential mapping converts the non-negative, channel-normalized squared feature residual rr into a bounded stereo-consistency weight, gstereo=exp⁡(−r/τ)g_{stereo}=\exp(-r/\tau). Exact left-right feature alignment gives r=0r=0 and gstereo=1g_{stereo}=1; increasing mismatch smoothly decreases the stereo contribution. We use this mapping because it is bounded in (0,1](0,1], monotonic, differentiable, requires no hard threshold, and uses a single temperature τ\tau to control sensitivity. It is an RBF-style deterministic similarity score, not an assumption that stereo correctness follows an exponential probability distribution.

 

C3/Q4. Why use the complementary stereo gate for monocular contribution?

1−gstereo1-g_{stereo} is a contribution-allocation coefficient inside the learned recurrent updater, not an estimate of monocular correctness. When left-right alignment is reliable, high gstereog_{stereo} preserves metric stereo evidence. When stereo support decreases in specular, weak-texture, occluded, or mismatched regions, the complementary weight reduces repeated reliance on the same uncertain stereo residual and increases the contribution of the corrected monocular candidate. This candidate is not an independent final prediction: it has already been conditioned by the stereo cost-volume latent state and aligned to the current stereo scale, while the updater continues to receive stereo correlation and state features. As shown in Supplementary Reliability-Weighted Contribution, this weighted contribution is also the minimizer of a local quadratic surrogate between the stereo representation and the corrected monocular representation. Replacing this spatial allocation with uniform mixing increases EPE from 3.05 to 3.30. Both candidates can still fail in the same region; the complementary gate controls contribution but does not guarantee that either candidate is correct.

 

C4/Q5. Gate weight maps

The paper assigns different contributions, rather than claiming that both branches attend to the same difficult regions. High wstereo=gstereow_{stereo}=g_{stereo} occurs where textured structures and left-right alignment provide reliable metric correspondence. High wmono=1−gstereow_{mono}=1-g_{stereo} occurs where stereo support is weak, including specular highlights, weak-texture tissue, occlusion or depth boundaries, and photometric mismatch; it increases the contribution of the corrected monocular context in these regions. A high wmonow_{mono} therefore indicates low stereo support, not guaranteed monocular correctness.

As rebuttal policy prohibits additional figures, we summarize the gate-map diagnostic. Across the 10 SCARED test keyframes, the top 20% monocular-gated pixels average approximately wstereo:wmono=0.14:0.86w_{stereo}:w_{mono}=0.14:0.86. They form localized clusters around highlights, occlusion/depth boundaries, and photometric mismatch rather than a uniform mixture. This observation, together with the uniform-mixing EPE increase from 3.05 to 3.30, supports spatially varying candidate allocation.

 

C5/Q6. Why a CNN stereo branch and a ViT monocular branch?

The two branches provide complementary information. The stereo branch constructs pair-specific metric correspondence, while the monocular branch supplies the fixed Depth Anything V2 prior and larger-context features. Its ViT architecture is inherited from Depth Anything V2 rather than selected as a claim that ViTs are intrinsically superior for monocular estimation.

With the monocular branch and remaining modules fixed, we replace only the stereo backbone:

Stereo backbone MAE ↓ EPE ↓
MobileNetV2 (Ours) 2.53 3.05
ResNet18 2.55 3.14
ConvNeXt 2.53 3.22
Swin-Tiny 2.58 3.21

The narrow MAE (2.53--2.58) and EPE (3.05--3.22) ranges show that the method does not depend on a specific stereo backbone. MobileNetV2 gives the lowest EPE and ties for the lowest MAE, supporting its use as the default.

 

C6. Visual Evidence For Degraded Regions

Because the rebuttal interface accepts text only, we provide the degraded-region analysis directly. We inspect aligned regions covering specular highlights, weak-texture tissue, smoke, occlusion or depth boundaries, instrument contact, tissue deformation, and photometric mismatch.

For each ROI, we compare the initial stereo hypothesis, corrected monocular candidate, final prediction, absolute error, degraded-region proxy, and gate response under a shared scale. Specular or saturated regions violate local photometric and feature consistency; weak-texture tissue makes the cost volume ambiguous; smoke introduces low-contrast partial occlusion; and occlusion boundaries, instrument contact, or tissue deformation create unmatched pixels and rapid local disparity changes. These factors lead to local errors in the initial stereo estimate that are difficult to distinguish in full-frame visualizations.

Across these regions, the initial stereo errors increase where left-right support becomes unreliable. Stereo evidence remains more active in visually and geometrically better-matched areas, while the corrected monocular candidate receives a larger contribution in ambiguous local regions. This is consistent with the gate-map diagnostic above and explains why the numerical improvements can be difficult to distinguish in full-frame disparity renderings.

 

Limitations

We agree that these concepts need clearer scope. The manuscript explains their endoscopic use and operational roles, but does not consolidate their boundaries. We clarify them here: Manifold refers to the locally linear yet globally nonlinear property of the correction geometry induced by the local decoder. We do not aim at global anatomical reconstruction or theoretical optimality, but focus on a concrete algorithm that fully exploits this manifold property for the applications. The local-energy analysis bounds decoded correction energy under stated assumptions. In the manuscript, our ablations provide empirical support. The exponential gate is a deterministic consistency score, not a calibrated probability: both candidates may fail together, and stereo-scale alignment depends on the current stereo estimate.

The evidence remains consistent: full refinement improves EPE from 3.55 for the parameter-matched one-step update to 3.05; path-energy regularization improves 3.84 to 3.05; and spatial gating improves 3.30 with uniform mixing to 3.05. Four stereo backbones yield 3.05-3.22 EPE, so the gain is not backbone-specific. The gate diagnostic further shows localized high-monocular allocation in ambiguous regions. We will state these scope conditions with the supporting evidence and prepared visualizations in the revised manuscript.

The complete efficiency comparison under the same measurement protocol is:

Method Params FLOPs Time Peak Mem
MSDESIS 3.30M 0.66T 19.32 ms 0.42 GiB
IGEV-Stereo 12.60M 7.29T 181.09 ms 1.35 GiB
GwcNet 6.52M 1.59T 187.33 ms 3.74 GiB
Selective-Stereo 13.14M 9.06T 234.13 ms 1.52 GiB
RAFT-Stereo 11.12M 10.28T 240.35 ms 2.05 GiB
ACVNet 7.17M 1.80T 245.79 ms 5.77 GiB
DynamicStereo 21.47M 3.72T 246.87 ms 6.18 GiB
Shi et al. 14.48M 7.08T 653.19 ms 6.13 GiB
Ours 47.99M 8.52T 275.54 ms 2.52 GiB

Our model requires 275.54 ms per stereo pair (3.63 FPS) and 2.52 GiB peak memory. Its 8.52T FLOPs are lower than Selective-Stereo (9.06T) and RAFT-Stereo (10.28T), while its latency remains in the same range as their 234.13/240.35 ms. At this comparable computational level, Manifold-Stereo reduces their SCARED EPE from 4.12/4.14 to 3.05 px and their SERV-CT EPE from 5.21/3.24 to 1.70 px, providing substantially stronger endoscopic disparity accuracy without a disproportionate increase in computation. Deployment at higher throughput is feasible with sufficiently provisioned computing resources.

Authors · CommentOpenReview ↗

Follow-up on the Manifold and Reliability Gate

Dear Reviewer jFq8,

As the NeurIPS rebuttal has entered Phase 2 discussion, we would appreciate your feedback on whether our response addresses your central concerns. We clarified the manifold as a local, cost-volume-centered latent geometry, its advantage over standard residual correction, and the assumptions and limitations of the reliability gate. We also addressed gate behavior, challenging-region evidence, backbone choice, and failure cases.

Could you let us know whether the theoretical clarification and mechanism-level evidence sufficiently support the claimed behavior? If you have more questions, we would be glad to address it and continue the technical discussion.

Thank you again for your feedback.

Authors · CommentOpenReview ↗

Phase 2 Follow-up on the Core Methodological Concerns

Dear Reviewer jFq8,

With two days remaining in the NeurIPS Phase 2 discussion period, we would like to follow up and offer any further clarification that may be useful. Our rebuttal directly addressed the local manifold formulation, its distinction from standard residual correction, the assumptions behind the reliability gate, and the requested mechanism-level analyses and limitations.

If any theoretical assumption, ablation, visualization, or aspect of the gate behavior remains insufficiently justified, we would be grateful if you could identify it. We remain fully available to answer additional questions and continue the technical discussion during the remaining time.

Thank you again for your careful and substantive feedback.

Authors · CommentOpenReview ↗

Final Phase 2 Follow-up on the Methodological Concerns

Dear Reviewer jFq8,

With the NeurIPS Phase 2 discussion period entering its final 24 hours, we would greatly appreciate knowing whether our rebuttal has addressed your concerns about the local manifold formulation, its advantage over simpler residual correction, the reliability gate, and the mechanism-level evidence in challenging regions.

If any theoretical assumption, experimental analysis, visualization, or limitation remains insufficiently addressed, please let us know. We remain fully available during the remaining discussion period and would welcome the opportunity to clarify or discuss any concern that is still unresolved.

Thank you again for your careful and substantive review.

Reviewer YPXvOpenReview ↗
Rating
5/6
Confidence
3/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper proposes Manifold-Stereo, a stereo-monocular disparity estimation framework for endoscopic images. The method first predicts a monocular disparity, refines it using a cost-volume-guided latent residual flow, and then adaptively fuses stereo and monocular information through a reliability gate based on left-right feature warping consistency. Experiments on SCARED, SERV-CT, and Hamlyn demonstrate improved disparity estimation performance over several recent stereo and endoscopic baselines.

Strengths and weaknesses

Strength

  1. Clear motivation. The paper aims to tackle an important problem in endoscopy, the stereo disparity estimation.
  2. The overall framework is intuitive and well-motivated: Using the stereo disparity to modify the monocular disparity and leaning on the monocular disparity only when the stereo disparity is unsure.
  3. Comprehensive experiments.

Weakness

  1. It's unclear why a continuous latent-flow formulation is necessary for the refinement compared to a simpler one.
  2. Lacks reports on the computational overhead.
Questions
  1. Why use the deature consistency to estimate the stereo reliability instead of using the confidence measure directly obtained from the stereo cost volume?
  2. How much additional inference time does the refinement introduce compared to the baseline stereo model? Could the method still satisfy real-time surgical requirements?
  3. From my understanding, it seems the method is applicable to general stereo matching beyond endoscopy. Has the author tested the method on other stereo datasets, like scenes with occlusions or reflective surfaces?
Limitations

Yes.

Final justification

The rebuttal addressed my main concerns with additional ablations supporting the multi-step latent refinement and reliability-gating design, as well as new Scene Flow results demonstrating applicability beyond endoscopy. The additional evidence strengthened the paper’s technical contribution and generalizability. Therefore, I maintain my Accept score.

Formatting concerns

None.

4 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We sincerely appreciate Reviewer YPXv for recognizing the clear motivation, intuitive framework, and comprehensive experiments of our work, and for providing constructive feedback that helps us further improve the paper. We respond to each question below.

 

W1. Why use continuous latent refinement instead of a simpler refiner?

The latent update provides a parameter-shared multi-step correction path initialized from stereo cost-volume geometry. Unlike a single residual prediction, its intermediate movement and endpoint are explicitly constrained relative to the pair-specific latent state.

Refinement MAE (mm) ↓ EPE (px) ↓
Full latent refinement 2.53 3.05
One-step update 2.82 3.55
Without path-energy loss 3.09 3.84

The one-step variant retains the same latent encoder, conditioning field, vector field, and decoder, so its 0.50 px higher EPE isolates the effect of the multi-step path rather than model capacity. The no-path-energy result further shows that the trajectory constraint is important. These details are reported in the Ablation Study and Supplementary Technical Scope of the Latent Residual Flow of our manuscript.

 

Q1. Why feature consistency instead of cost-volume confidence?

Feature consistency directly evaluates whether the current continuous disparity aligns the left and warped-right descriptors, and it is recomputed after every recurrent update. A confidence value derived from the discrete cost-volume distribution instead describes ambiguity among sampled disparity hypotheses before the current continuous estimate is verified. The former is therefore aligned with the quantity being updated, while the latter remains useful for cost aggregation but does not directly measure post-update left-right agreement.

The uniform-mixing ablation increases MAE/EPE from 2.53/3.05 to 2.63/3.30, showing that a location-dependent consistency signal is more effective than assigning the same contribution everywhere. The definition and this distinction are stated in Geometric Consistency-Gated Recurrent Refinement of our manuscript.

 

Q2. Inference time and real-time operation

Method Params FLOPs Time Peak Mem
MSDESIS 3.30M 0.66T 19.32 ms 0.42 GiB
IGEV-Stereo 12.60M 7.29T 181.09 ms 1.35 GiB
GwcNet 6.52M 1.59T 187.33 ms 3.74 GiB
Selective-Stereo 13.14M 9.06T 234.13 ms 1.52 GiB
RAFT-Stereo 11.12M 10.28T 240.35 ms 2.05 GiB
ACVNet 7.17M 1.80T 245.79 ms 5.77 GiB
DynamicStereo 21.47M 3.72T 246.87 ms 6.18 GiB
Shi et al. 14.48M 7.08T 653.19 ms 6.13 GiB
Ours 47.99M 8.52T 275.54 ms 2.52 GiB

Our model requires 275.54 ms per stereo pair (3.63 FPS) and 2.52 GiB peak memory. Its 8.52T FLOPs are lower than Selective-Stereo (9.06T) and RAFT-Stereo (10.28T), while its latency remains in the same range as their 234.13/240.35 ms. At this comparable computational level, Manifold-Stereo reduces their SCARED EPE from 4.12/4.14 to 3.05 px and their SERV-CT EPE from 5.21/3.24 to 1.70 px. The measured throughput reflects the current hardware configuration; deployment at higher throughput is feasible with sufficiently provisioned computing resources. We will add this experiment in our revised manuscript.

 

Q3. Applicability beyond endoscopy

We additionally evaluate Manifold-Stereo on the Scene Flow general-scene stereo benchmark:

Method EPE (px) ↓
GwcNet 0.76
LEAStereo 0.78
ACVNet 0.48
IGEV 0.47
Selective-IGEV 0.44
Manifold-Stereo (Ours) 0.38 (-13.64%)

Our method achieves the lowest EPE among the compared methods, reducing the error by 13.64% relative to Selective-IGEV. This result directly demonstrates that the proposed refinement is also effective beyond endoscopy. Its benefit is even larger on the challenging endoscopic cross-domain SERV-CT benchmark, where EPE decreases from 2.63 to 1.70 px, a 35.36% relative reduction. The Scene Flow result provides the general-scene validation identified in Supplementary section VI Domain Applicability of Reliability-Gated Candidate Contribution of our manuscript. The larger relative EPE reduction on SERV-CT is consistent with the locally coherent tissue geometry and spatially concentrated correspondence failures caused by specular reflection, weak texture, smoke, wet tissue, and instruments, as discussed in that section.

Authors · CommentOpenReview ↗

Follow-up on Refinement Design and Efficiency

Dear Reviewer YPXv,

The NeurIPS rebuttal is now in Phase 2 discussion. We would like to ask whether our response has resolved your questions about the latent-flow formulation, feature consistency versus cost-volume confidence, and the refinement module's runtime.

We aimed to clarify the role of parameter-shared, path-regularized refinement relative to a simple residual update, the complementary confidence signals, and the method's efficiency and generalization scope. If any further questions, please let us know. We would be very happy to provide more evidence or discuss it in more detail.

Thank you for engaging with the technical details of our work.

Reviewer YPXv · CommentOpenReview ↗

Thank you for the detailed response and the additional experimental evidence. The authors have satisfactorily addressed my questions and demonstrated the broader applicability of the method. I appreciate the effort put into addressing my questions. I will keep my current Accept score.

Authors · CommentOpenReview ↗

Dear Reviewer YPXv,

Thank you very much for your follow-up and for confirming that our rebuttal addressed your questions. We sincerely appreciate your careful review, constructive questions, and positive assessment of the additional evidence and the broader applicability of our method.

Your feedback helped us present the motivation for the latent refinement, confidence design, computational trade-offs, and generalization scope more clearly. We are grateful for the time and attention you devoted to evaluating our work and for your recognition of our efforts to strengthen the paper.

Thank you again for your thoughtful consideration.

Reviewer PoabOpenReview ↗
Rating
5/6
Confidence
4/5
Quality
4/4
Clarity
3/4
Significance
4/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The paper addresses the problem of endoscopic stereo matching, which is challenging due to weak-texture, specular, occluded, and deformed regions in the same frame. While foundation stereo and monocular priors have been used to improve stereo matching, they may treat monocular guidance as an "independently predicted candidate," overriding stereo pairs for which there is already strong evidence. The authors propose Manifold-Stereo, a method that refines foundation monocular disparity candidates using a match cost volume geometry, calibrating the corrected candidate to the stereo pair. Evaluation is performed on the SCARED dataset, with zero-shot evaluation on SERV-CT and Hamlyn datasets. The results show that Manifold-Stereo outperforms state-of-the-art methods on average on SCARED, but on individual test sets it does not consistently outperform all other methods. In the zero-shot evaluation on SERV-CT, it outperforms all other methods by a significant margin.

Strengths and weaknesses

Strengths

  • The paper addresses a relevant problem in endoscopic stereo matching, which has practical applications especially in robot-assisted surgery.
  • The proposed method, Manifold-Stereo, introduces a novel approach to refine monocular disparity candidates, grounding the approach in a solid mathematical framework. A correlation volume is encoded into a spatial latent field, pooled along the disparity dimension, and then used to condition residual flow in a correction space.
  • The description of the above, although complex, is well-structured, with a good balance between technical depth and clarity. The paper includes a detailed explanation of the method, supported by figures that help illustrate the concepts.
  • The experimental evaluation uses the SCARED dataset for training, with testing on the SCARED test split and zero-shot evaluation on SERV-CT and Hamlyn datasets. The results show that Manifold Stereo outperforms state-of-the-art methods on average on SCARED, but on individual test sets it does not consistently outperform all other methods. In the zero-shot evaluation on SERV-CT, it outperforms all other methods by a significant margin.

Weaknesses

  • Model performance on SCARED (test set 1 and 2) and Hamlyn is not consistently better than all other methods across metrics. While the method shows strong performance on SERV-CT, it performed worse than other methods on SCARED and Hamlyn. This may be due to the substantial difficulty in obtaining ground truth and the small amount of testing data available for these datasets.
  • Qualitative visualizations of the results fail to demonstrate the claimed improvements in the paper, with virtually indistinguishable predictions visually compared to other methods, all of which don't resemble the ground truth on the SCARED and Hamlyn datasets, at least visually. Because of this, it is difficult to clearly see the improvements in the results reflected in the qualitative visualizations.

Justification of Rating

Although the paper has some weaknesses, the proposed method is technically solid and shows exceptionally strong performance on the SERV-CT dataset, with reasonable performance compared to baselines on SCARED and Hamlyn. While the qualitative visualizations do not clearly demonstrate the improvements, the quantitative results on SERV-CT are compelling. The paper is well-written and structured, with a clear explanation of the method and its contributions. Overall, the paper makes a valuable contribution to the field of endoscopic stereo matching, and I recommend acceptance.

Questions

N/A

Limitations

Yes

Formatting concerns

None

4 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We sincerely thank Reviewer Poab for recognizing the technical soundness and clear presentation of our work, as well as its strong performance on SERV-CT. We address the reviewer’s concerns regarding the quantitative and qualitative analyses point by point below.

 

W1. Performance across SCARED subsets and Hamlyn metrics

1. The per-keyframe variation is dataset-wide rather than specific to Manifold-Stereo. In our table, Test 1 K0 is the hardest keyframe for every method (7.35-8.64 mm), whereas K4 is much easier (0.56-1.04 mm). Test 2 shows the same pattern: K0 is 4.14-4.75 mm, while K1 is 0.89-1.18 mm for the competitive stereo methods. The original SCARED challenge paper [1] also reports large cross-keyframe variation across independent submissions.

2. The main cause is view-dependent difficulty. Each keyframe differs in working distance, disparity range, tissue appearance, texture, specular reflection, and occlusion or boundary distribution. Moreover, depth is inversely related to disparity, so a similar pixel disparity error can produce a larger Depth MAE at a longer working distance. The calibration and RGB-GT alignment inaccuracies documented by SCARED can further affect individual keyframes. Together, these factors explain why performance and the best-performing method vary across views.

3. Our Manifold-Stereo remains strongest on the difficult keyframes and in the aggregate SCARED evaluation. It is best on Test 1 K0 (7.35 mm), ties the best result on Test 2 K0 (4.14 mm), and is best on Test 2 K2/K3 (2.69/1.43 mm). More importantly, it achieves the best aggregate result on every reported SCARED metric, including Depth MAE (2.53 mm) and EPE (3.05 px). Thus, isolated per-keyframe rankings reflect heterogeneous view difficulty, while the aggregate results show consistent overall robustness.

4. On Hamlyn, the metric pattern reflects sensitivity to different error ranges. Our method achieves the best EPE (4.24 px) and Bad3 (27.96%), while D1 and Bad2 are only 0.58 and 0.09 percentage points from the best. Bad1 uses the strictest one-pixel threshold and is more sensitive to small residual shifts after cross-domain stereo-scale alignment, whereas EPE and Bad3 better reflect the error magnitude and larger-error regions targeted by our local refinement. The same unchanged model is best on all SERV-CT metrics, including EPE (1.70 vs. 2.63 px). We will add this metric-specific explanation to the Quantitative Analysis subsection.

 

W2. Qualitative visibility of the improvements

1. Why the differences are difficult to see. A full-frame color map encodes absolute disparity rather than error. The SCARED visualization spans 0-192 px, whereas our aggregate EPE gain over the strongest baseline is 0.34 px (3.39 to 3.05 px), only about 0.18% of that range. The gain is also concentrated in small specular, weak-texture, occlusion/boundary, fold, and instrument-contact regions, which occupy little of the full image. In addition, SCARED and Hamlyn contain invalid or partially valid GT regions that are excluded from evaluation but remain visually empty beside dense predictions.

2. How we will make the improvements directly visible. We have reorganized the qualitative analysis to include more examples with (1) common-scale absolute-error maps on the same valid GT pixels used for evaluation, (2) error-change maps relative to the strongest baseline, and (3) enlarged, boxed ROIs marking regions prone to incorrect estimation. Each ROI will show the input, GT, baseline and our predictions, absolute errors, and local EPE using the same crop and scale. Because NeurIPS policy prohibits additional attachments or external links during rebuttal, these prepared visualizations will be presented in the revised manuscript.

3. How the visual evidence will connect to our method. We will align the gate map with each ROI to show whether reduced stereo consistency and increased monocular contribution occur in ambiguous regions, while stronger stereo contribution is retained in well-matched areas. This will make both the location of the improvements and their connection to reliability-gated refinement explicit.

 

Reference

[1] Allan, M., Mcleod, J., Wang, C., Rosenthal, J.C., Hu, Z., Gard, N., Eisert, P., Fu, K.X., Zeffiro, T., Xia, W. and Zhu, Z., 2021. Stereo correspondence and reconstruction of endoscopic data challenge. arXiv preprint arXiv:2101.01133.

Authors · CommentOpenReview ↗

Follow-up on Quantitative and Qualitative Evidence

Dear Reviewer Poab,

As NeurIPS has entered the Phase 2 rebuttal discussion, we would like to ask whether our response has addressed your concerns. We clarified the distinction between aggregate performance and individual SCARED/Hamlyn results, tempered the corresponding claims, and strengthened the interpretation of the qualitative and region-level evidence.

We would appreciate knowing whether this resolves your concerns about the non-uniform metrics and the original visual comparisons. Please let us know if you have more questions. We would be glad to clarify any remaining issues and continue the discussion.

Thank you again for your constructive assessment.

Authors · CommentOpenReview ↗

Follow-up on the Remaining Evidence

Dear Reviewer Poab,

As only two days remain in the NeurIPS Phase 2 discussion period, we hope to have further discussions with you. In our rebuttal, we addressed the distinction between aggregate and per-subset performance, tempered the corresponding claims, and clarified the qualitative and region-level evidence.

If any concern about the non-uniform metrics, visual comparisons, or interpretation of the results remains unresolved, please let us know. We would be glad to provide further clarification or discuss any additional evidence that would help you assess the work during the remaining discussion period.

Thank you again for your constructive review and consideration.

Authors · CommentOpenReview ↗

Phase 2 Follow-up on the Remaining Concerns

Dear Reviewer Poab,

As only 24 hours remain in the NeurIPS Phase 2 discussion period, we would be grateful to know whether our rebuttal has resolved your concerns regarding the per-subset and Hamlyn results, the scope of our performance claims, and the clarity of the qualitative evidence.

If any aspect of the quantitative interpretation or visual analysis remains unconvincing or requires further explanation, please let us know. We are very willing to provide additional clarification and discuss any concern that remains during the available discussion time.

Thank you again for your constructive evaluation of our work.

Reviewer KxqXOpenReview ↗
Rating
3/6
Confidence
2/5
Quality
2/4
Clarity
2/4
Significance
2/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The manuscript presents the Manifold-Stereo network for endoscopic stereo disparity estimation. The Manifold-Stereo network refines monocular disparity candidates through a residual flow conditioned on stereo cost volume. And the Manifold-Stereo network uses geometric consistency gate to fuse the monocular and stereo disparities. The Manifold-Stereo network achieves the state-of-the-art performance on in-domain SCARED and zero-shot SERV-CT and Hamlyn evaluation.

Strengths and weaknesses

Strengths:

  1. The Manifold-Stereo achieves state-of-the-art accuracy on several datasets.
  2. It is interesting to use flow conditioned on stereo cost volume to correct the monocular disparities.

Weaknesses:

  1. Some words are confusing, for example:

(a) "Manifold" in the title. What does it refer to? It is not explained in the main text.

(b) "Stereo evidence" in line 31. "Stereo support" in line 53.

(c) "Calibrated stereo" in line 41, "Calibrated matching" in line 124, "uncalibrated disparity-like candidate" in line 153. In the context of stereo matching, "calibration" usually means to estimate camera parameters. What does the "calibration" mean in your manuscript?

(d) "anatomical manifold" in line 180.

(e) "latent anchor" in line 182. In my understanding, "anchor" is often used in object detection, planning, and so on. But it is not popular in stereo matching. What does "anchor" mean in your manuscript?

  1. Unreasonable design: In equation (2), the \Psi() function takes only Z as input, without information for D_{mono}. Does \Psi know how much should be corrected?

  2. In table 1 and table 2, why the compared methods are different? In table 2 and 3, what are the training sets for different methods? Are they trained on the same training set?

Questions
  1. Please explain the words mentioned in weakness.
  2. It would be great to add inference time and memory.
Limitations

The authors didn't mention the limitations.

Final justification

The author solved most of my questions. However, I still have the concern about the effectiveness of the monocular disparity. The monocular disparity DmonoD_{mono} is expected to be an important component in the local correction space (Eq. (2)). However, in my humble opinion, there is no fair ablation to show that DmonoD_{mono} is important or useful. Therefore I keep my score to be 3.

Formatting concerns

No

12 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We appreciate Reviewer KxqX’s positive assessment of Manifold-Stereo’s strong performance and interest in its cost-volume-conditioned refinement. We address all concerns and questions point by point below.

 

W1/Q1. Terminology

We clarify the five terms separately because they refer to different stages of the method:

  • Manifold/local correction space: for each stereo pair, the cost-volume latent state and residual decoder define the local set of reachable disparity corrections. Manifold refers to this decoder-induced, locally structured correction geometry, not a global anatomical manifold.
  • Stereo evidence/support: evidence denotes the cost-volume and descriptor matches used to construct metric correspondence; support denotes how well the current disparity is confirmed by left-right feature alignment. Neither is an additional supervision signal.
  • Calibrated stereo and monocular alignment: calibrated stereo retains its standard meaning: disparity from a rectified pair with known camera calibration provides the metric reference. The monocular candidate has an unknown relative scale and offset, so its affine fit to the current stereo estimate is called per-pair stereo-scale alignment. This operation does not estimate or modify camera parameters.
  • Anatomical manifold: we use monocular anatomical context instead, describing the larger-context prior supplied by Depth Anything V2 without implying a global anatomical surface model.
  • Latent anchor: this is sg⁡(Z0)\operatorname{sg}(Z_0), the fixed reference used by the endpoint loss. We call it the stop-gradient reference state, avoiding the unrelated object-detection meaning of anchor.

These distinctions preserve the central design: stereo provides pair-specific metric geometry, while the monocular branch provides contextual information whose correction and contribution remain controlled by that geometry. The local-space and reference-state definitions appear in Section 3. Methodology: Conditional Latent Residual Flow in a Local Correction Space; the alignment operation appears in Section 3. Methodology: Geometric Consistency-Gated Recurrent Refinement and Supplementary Section IV. Training Objective Details. We will use the clarified terms consistently in the revised manuscript.

 

W2. Why does the correction decoder not explicitly take the monocular estimate as input?

The equation should be read as a residual formulation:

Dmono,corr=Dmono+ΔDmonoD_{mono,corr}=D_{mono}+\Delta D_{mono},

ΔDmono=ψ(ZT).\Delta D_{mono}=\psi(Z_T).

ψ\psi does not predict a complete disparity map; it predicts only the correction relative to DmonoD_{mono}, which is already the base point. The decoded-disparity loss is applied to their sum, so the prediction error directly supervises the required residual magnitude. The residual is image-dependent because Z0Z_0 is encoded from the pair-specific stereo cost volume after multi-scale monocular feature transfer, and the vector field is conditioned on the matching descriptor. Therefore, ZTZ_T contains the monocular context and current stereo-pair geometry needed by ψ\psi; the output is not a fixed offset independent of DmonoD_{mono}.

This factorization prevents the decoder from replacing the monocular candidate with an unconstrained full-disparity prediction. Instead, it restricts the learned output to a stereo-conditioned correction, followed by per-pair stereo-scale alignment before recurrent refinement. Removing the local correction space increases MAE/EPE from 2.53/3.05 to 2.60/3.27, while the parameter-matched one-step update gives 2.82/3.55. These results support the benefit of the cost-volume-conditioned correction rather than direct residual capacity alone. The complete dependency is specified in Conditional Latent Residual Flow in a Local Correction Space and Supplementary Spatial Latent Field and Residual-Flow Refinement.

 

W3. Different methods and training sets in Tables 1-3

The method-set difference is caused only by input applicability. Table 1 evaluates SCARED: all stereo-pair methods are included, while DynamicStereo is reported only for sequential keyframes and marked unavailable for the single-frame K4 cases. Table 2 evaluates static SERV-CT stereo pairs, so DynamicStereo cannot be applied. Table 3 evaluates Hamlyn videos, where its sequential input is available and it is therefore included. All other methods are reported consistently across the applicable tables.

The common protocol is already specified in Datasets and Training and Evaluation Setup. Every reproduced method is trained using the same SCARED split and training-validation protocol. SERV-CT and Hamlyn use the SCARED-selected checkpoints directly, without target-domain fine-tuning for any method. Therefore, the different table entries do not reflect different training data or selective baseline removal; they reflect whether the required static-pair or sequential input exists. We will state this exception directly in the affected table notes.

 

Q2. Inference time and memory

Method Params FLOPs Time Peak Mem
MSDESIS 3.30M 0.66T 19.32 ms 0.42 GiB
IGEV-Stereo 12.60M 7.29T 181.09 ms 1.35 GiB
GwcNet 6.52M 1.59T 187.33 ms 3.74 GiB
Selective-Stereo 13.14M 9.06T 234.13 ms 1.52 GiB
RAFT-Stereo 11.12M 10.28T 240.35 ms 2.05 GiB
ACVNet 7.17M 1.80T 245.79 ms 5.77 GiB
DynamicStereo 21.47M 3.72T 246.87 ms 6.18 GiB
Shi et al. 14.48M 7.08T 653.19 ms 6.13 GiB
Ours 47.99M 8.52T 275.54 ms 2.52 GiB

Our model requires 275.54 ms per stereo pair (3.63 FPS) and 2.52 GiB peak memory; the parameter count includes the frozen Depth Anything V2 branch. Its 8.52T FLOPs are lower than Selective-Stereo (9.06T) and RAFT-Stereo (10.28T), while its latency remains in the same range as their 234.13/240.35 ms. Its peak memory is also lower than GwcNet, ACVNet, DynamicStereo, and Shi et al. At this comparable computational level, Manifold-Stereo reduces the SCARED EPE of Selective-Stereo/RAFT-Stereo from 4.12/4.14 to 3.05 px, and their SERV-CT EPE from 5.21/3.24 to 1.70 px. The result demonstrates substantially stronger endoscopic disparity accuracy without a disproportionate increase in computation. Deployment at higher throughput is feasible with sufficiently provisioned computing resources.

 

Limitations

The Conclusion already discusses the limitation that Manifold-Stereo processes frames independently without enforcing temporal consistency. We nevertheless agree that the scope and limitations should be stated more explicitly and consolidated. Manifold-Stereo targets disparity estimation from each rectified stereo pair; video-level temporal reconstruction is a useful system extension but lies outside the claimed per-frame evaluation objective. Likewise, prospective clinical workflow validation is required before deployment, while the present claim concerns disparity-estimation accuracy rather than a clinical outcome.

Within the target task, the main limitation is that the gate allocates contribution but cannot guarantee that either candidate is correct. Stereo and monocular candidates may fail simultaneously in severely degraded regions, and per-pair stereo-scale alignment depends on the current stereo estimate. However, the monocular candidate is not used as an unconstrained replacement: it is first corrected by cost-volume geometry, aligned to stereo scale, and introduced through a spatial gate while the updater retains stereo correlation. The uniform-mixing ablation increases EPE from 3.05 to 3.30, removing candidate calibration increases it to 4.32, and the unchanged model achieves 1.70 px EPE on zero-shot SERV-CT. These results show that the proposed controls remain effective under the evaluated domain shift while defining the conditions in which both evidence sources may become unreliable.

Computational cost is quantified in Q2 rather than treated as an unspecified limitation. The model operates at a comparable computational level to strong iterative stereo methods while providing substantially lower endoscopic EPE. We will state these task boundaries and system-level extensions separately in the revised manuscript.

Authors · CommentOpenReview ↗

Follow-up on Method Clarifications and Evaluation Protocol

Dear Reviewer KxqX,

As the NeurIPS rebuttal has entered Phase 2 discussion, we would like to follow up on your concerns. Our response clarified the local-correction and stereo-scale-alignment terminology, the conditioning dependencies in Eq. (2), the protocols behind Tables 1-3, and the requested computational costs.

Could you kindly let us know whether these clarifications address your main concerns, especially the role of the monocular candidate and the fairness of the cross-dataset comparisons? If any definition, design choice, or protocol remains unclear or insufficiently supported, we would be grateful to discuss it further and provide any additional details needed.

Thank you again for your careful consideration.

Authors · CommentOpenReview ↗

Phase 2 Follow-up on Remaining Clarifications

Dear Reviewer KxqX,

With two days remaining in the NeurIPS Phase 2 discussion period, we would like to follow up once more and remain available to address any unresolved concerns. Our rebuttal focused on the terminology, the conditioning in Eq. (2), the training and evaluation protocols, comparison fairness, and computational overhead.

If any of these explanations are still unclear or do not fully address your original questions, we would greatly appreciate knowing which point requires further clarification. We are happy to provide additional details or discuss any remaining technical issues during the time available.

Thank you again for your time and consideration.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Missing a submission?

Loading the discussion…