potentialpaper

RadOmni: Advancing Foundation Model for Non-contrast CT with Omni Radiology Knowledge

Fenghe Tang, Weiwei Cao, Wenxin Ma, Kai Cao, Huanhuan Liu, Ling Zhang, S Kevin Zhou, Jianpeng Zhang

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

TL;DR. A unified omni-pretraining framework that injects diverse radiology knowledges into representation learning for non-contrast CT

Abstract. Non-contrast CT (NCCT) is widely used in clinical practice, yet its limited soft-tissue contrast often renders visual information insufficient for accurate diagnosis. In routine radiology workflows, NCCT is commonly accompanied by contrast-enhanced CT, radiology reports, and pathology reports, which provide complementary knowledge at different levels, from structural and morpho-functional cues to semantic findings and pathological evidence. However, existing pretraining paradigms address this challenge only partially, each introducing complementary but still limited constraints on NCCT representations. To address this limitation, we propose RadOmni, a unified omni-pretraining framework that injects multimodal radiology knowledge into representation learning for non-contrast CT. RadOmni formulates a curriculum consolidation learning strategy, in which knowledge is progressively injected according to optimization difficulty and knowledge level through four stages: masked image modeling on non-contrast CT, cross-phase transfer of anatomical structures and enhanced patterns from contrast-enhanced CT, report-guided semantic learning, and pathology-informed diagnostic enhancement. To mitigate optimization conflicts across heterogeneous objectives and reduce knowledge forgetting, each stage retains and jointly optimizes the objectives from preceding stages, while early encoder layers are selectively frozen to preserve generic representations. To enable such multi-source pretraining, we curate Omni-CT10K, a large-scale CT dataset with more than 10K NCCT scans featuring clinically co-occurring multimodal supervision. Extensive experiments on Omni-CT10K, two in-house benchmarks from different centers, and the public benchmarks show that RadOmni consistently achieves strong performance across classification, segmentation, pathological TNM staging, and radiology report generation tasks. Further analyses demonstrate favorable scaling behavior, robust cross-center generalization, and transferable representations.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
27 Apr 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:48 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

The paper proposes a staged training framework for non-contrast CT images that transfers knowledge from contrast-enhanced CT, radiology reports, and pathology reports.

Many of the reviewers’ concerns could be addressed by providing additional technical details, including the rationale for the ordering of the training stages, the method’s generalizability to other organs, and the error propagation between stages.

Final justification

The authors have added external evaluation experiments that strengthen the empirical analysis. I encourage them to incorporate these results into the final manuscript and to further narrow or qualify any claims that extend beyond the evidence presented.

Area Chair HbwA · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

The paper proposes a staged training framework for non-contrast CT images that transfers knowledge from contrast-enhanced CT, radiology reports, and pathology reports.

Many of the reviewers’ concerns could be addressed by providing additional technical details, including the rationale for the ordering of the training stages, the method’s generalizability to other organs, and the error propagation between stages.

Final justification

The authors have added external evaluation experiments that strengthen the empirical analysis. I encourage them to incorporate these results into the final manuscript and to further narrow or qualify any claims that extend beyond the evidence presented.

Reviewer Gq9sOpenReview ↗
Rating
4/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper introduces RadOmni, a foundation model framework aimed at overcoming the inherent low soft-tissue contrast of Non-Contrast CT (NCCT) by progressively integrating multimodal clinical knowledge. The authors propose a four-stage curriculum consolidation strategy that sequentially injects structural priors from NCCT, cross-phase anatomical features from Contrast-Enhanced CT (CECT), semantic context from radiology reports, and diagnostic cues from pathology reports. Instead of joint training, the method employs a progressive layer-freezing mechanism and retains previous loss functions to prevent optimization interference and catastrophic forgetting. To facilitate this complex training pipeline, the authors curated Omni-CT10K, a proprietary dataset of over 10,000 multi-modal NCCT cases, and demonstrate the model's performance across various downstream medical tasks.

Strengths and weaknesses

Strengths Strong Clinical Motivation and Relevance: The paper addresses a highly practical clinical problem, the limited soft-tissue contrast of Non-Contrast CT (NCCT). The approach of injecting complementary knowledge from Contrast-Enhanced CT (CECT), radiology reports, and pathology reports perfectly aligns with real-world clinical diagnostic workflows, providing a highly logical foundation for the research.

Effective Curriculum Consolidation Strategy: The proposed four-stage progressive learning framework is well-designed. Rather than simply employing joint training, the authors thoughtfully implement a progressive freezing strategy. The ablation studies, particularly the effective rank analysis, successfully demonstrate that this strategy mitigates optimization interference and prevents catastrophic forgetting of previously acquired representations.

Significant Data Curation Effort: The curation of Omni-CT10K, which contains over 10,000 multi-modal data pairs (NCCT, CECT, reports, pathology, and masks), represents a massive undertaking. This comprehensive dataset serves as a robust groundwork for training the proposed omni-pretraining framework.

Weaknesses Critical Lack of Reproducibility due to Closed Dataset: While the paper positions RadOmni as a "Foundation Model," its core performance relies heavily on the proprietary Omni-CT10K dataset. Since this dataset is private and no representative samples are provided, the research community cannot verify the data quality or reproduce the foundation model's claimed capabilities.

Omission of State-of-the-Art Public Benchmarks: The external validation relies on the outdated MSD dataset, which is insufficient for proving the generalizability of a foundation model. The authors completely omit evaluations on recent large-scale public benchmarks. For instance, to truly validate the text-to-image semantic understanding and report generation capabilities, evaluating the model on datasets like CT-RATE (which provides over 40,000 NCCT-report pairs) is essential.

Insufficient Cross-Modal Validation on Open Data: To robustly justify the cross-phase knowledge transfer from CECT to NCCT (Stage 2), the framework must be tested on established public datasets that contain explicit NCCT-CECT pairs and organ/lesion masks, such as KiTS19 or relevant collections from TCIA. Relying primarily on internal benchmarks weakens the claim of strong cross-center generalization.

Marginal Methodological Novelty: The individual components of the four stages, Masked Image Modeling (S1), Logit Distillation (S2), and Learnable Query-based Contrastive Learning (S3, S4), are standard techniques in the field. While the orchestration of these methods into a single pipeline is commendable, the framework reads more like a heuristic combination of existing techniques rather than introducing a fundamentally novel 3D architectural design for medical foundation models.

Questions
  1. Clarifying Methodological Novelty and Architectural Innovation The proposed four-stage curriculum integrates Masked Image Modeling (S1), Logit Distillation (S2), and Learnable Query-based Contrastive Learning (S3, S4). While the orchestration is logical, these are fundamentally standard techniques. Does RadOmni introduce any novel architectural modifications specifically tailored to the unique spatial properties of 3D medical volumes, or is the core contribution strictly the heuristic sequencing of these existing methods?

  2. Strengthening Claims of Generalization via Modern Public Benchmarks The external validation relies heavily on the older MSD benchmark. Given that this is positioned as a "Foundation Model" for NCCT, why were more recent, large-scale public datasets omitted from the evaluation? To substantiate the claim that RadOmni is a generalized foundation model, it is highly recommended to evaluate it on contemporary large-scale benchmarks. For the cross-phase transfer (CECT to NCCT in Stage 2), please provide experimental results on public datasets that contain explicit NCCT-CECT pairs and masks, such as KiTS19 or relevant collections from TCIA. For report-guided semantic learning and report generation tasks, validating the model on the recently released CT-RATE dataset (which contains over 40,000 NCCT-report pairs) would significantly strengthen the paper's claims.

  3. Addressing Reproducibility and the Closed Dataset A major pillar of this work is the curation of the Omni-CT10K dataset. However, since this dataset is private, how can the research community verify the data distribution, reproduce the foundation model's baseline, or build upon this framework? The lack of access to Omni-CT10K limits the paper's impact and reproducibility. While privacy constraints are understandable, please provide highly detailed statistical distributions of the dataset. Furthermore, strongly consider releasing the pre-trained weights of RadOmni, the source code for the 4-stage training pipeline, and potentially a small, anonymized "toy" subset of the data so peer researchers can validate the methodology.

  4. Computational Overhead of the Curriculum Strategy The ablation studies convincingly argue that the 4-stage progressive freezing strategy prevents the segmentation performance degradation seen in joint training. However, what is the computational cost (e.g., total GPU hours, memory footprint) of this sequential 4-stage pipeline compared to a single-stage joint training approach? Please include a brief computational complexity analysis (efficiency vs. performance trade-off). This will help readers understand if the marginal gains in certain downstream tasks justify the potentially massive computational overhead of training a model through four distinct, cumulative stages.

Limitations

The authors have not adequately addressed the limitations of their work, as a dedicated "Limitations" section appears to be missing from the manuscript. I strongly recommend adding a section that critically discusses the boundaries and constraints of the proposed framework. Specifically, the authors should explicitly address the implications of the points raised in the "Weaknesses" sections above.

Final justification

I thank the authors for their comprehensive rebuttal and the extensive additional experiments (e.g., CT-RATE, PLCC, and computational cost analysis). Most of my concerns have been successfully addressed. I will update my final score accordingly.

Formatting concerns

.

3 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We appreciate your thoughtful feedback and accolades on our contribution: "Strong Clinical Motivation and Relevance", "Well-designed Curriculum Consolidation Strategy", and " with ablation studies that "successfully demonstrate". We also value your acknowledgment that the curation of Omni-CT10K "represents a massive undertaking" and "serves as a robust groundwork." Below, we address each of your concerns point by point.

Q1. The external validation on recent large-scale public benchmarks CT-RATE.

Response: We have added experiments on CT-RATE using its official data split and the zero-shot diagnosis protocol of fVLM. To ensure a controlled comparison, we retain the same contrastive-learning framework, text encoder, preprocessing, and evaluation protocol, and replace only the visual backbone and its initialization with the nnUNet encoder pretrained by RadOmni and evaluate zero-shot text-to-image semantic understanding task. As shown in the table, RadOmni outperforms CT-CLIP, fVLM, and ViSD-Boost across Precision, ACC, F1, and AUC, providing further evidence that RadOmni learns transferable representations on large-scale public NCCT-report data. We interpret this result cautiously, since our data construction is focused on abdominal colorectal cancer; thus, validation on CT-RATE serves only as supplementary evidence of transfer potential, not conclusive proof of cross-organ generalization.

Table R2. Zero-shot performance comparison on the CT-RATE.

Method Precision ACC F1 AUC
CT-CLIP 32.6 66.9 70.8 73.3
fVLM 37.9 71.8 75.1 77.8
ViSD-Boost 38.7 73.1 75.9 79.0
RadOmni 40.2 74.3 77.0 79.8

Q2. Cross-Modal Validation on Open Data.

Response: We additionally evaluated RadOmni on two public multiphase CT datasets, the Primary Liver Cancer CECT (PLCC) dataset [ref1] and TriALS [ref2]. PLCC provides liver and lesion masks across NCCT, arterial, venous, and delayed phases, and TriALS, which provides liver-lesion annotations for NCCT and venous phases. Following the standard nnUNet protocol, we conducted 5-fold cross-validation on both datasets. The results show consistent improvements from RadOmni pretraining across both organ and lesion segmentation, and across both non-contrast and contrast-enhanced phases. Notably, on PLCC, the NCCT lesion Dice with RadOmni initialization reaches 59.06, surpassing the arterial-phase baseline without pretraining (58.82). This further suggests that the cross-phase knowledge introduced during pretraining can effectively enhance NCCT representations, and that this benefit is not limited to internal data.

Table R3. Segmentation results (Dice, mean ± std) on the Primary Liver Cancer CECT (PLCC) dataset.

Phase Organ (Baseline) Organ (RadOmni) Δ Lesion (Baseline) Lesion (RadOmni) Δ
NCCT 91.79±1.55 92.12±1.58 +0.33 56.02±2.19 59.06±1.38 +3.04
Arterial 93.05±1.33 93.24±1.34 +0.19 58.82±2.32 61.40±1.70 +2.58
Venous 93.84±1.42 93.87±1.45 +0.03 64.25±2.70 66.60±2.19 +2.35
Delayed 93.91±1.67 94.06±1.63 +0.15 62.41±4.15 65.10±1.66 +2.69

Table R4. Segmentation results (Dice, mean ± std) on the TriALS dataset.

Phase Lesion (Baseline) Lesion (RadOmni) Δ
NCCT 33.42±7.04 38.60±4.42 +5.19
Venous 49.07±2.12 52.06±3.76 +2.99

Ref1: Comprehensive multi-phase 3D contrast-enhanced CT imaging for primary liver cancer. Scientific Data, 2025.

Ref2: TriALS: Triphasic-Aided Liver Lesion Segmentation Benchmark in Non-Contrast CT. arXiv, 2026.

Q3. The novelty of the proposed method.

Response: We would like to clarify that the main contribution of this work lies not in the individual techniques used at each stage, nor in introducing a new 3D architectural block, but in two main aspects. (1) New problem formulation. Prior work typically focuses on a single paradigm, such as self-supervised learning, supervised pretraining, or vision-language pretraining. In contrast, our goal is not to pursue isolated SSL/VLP/SP, but to address the information-limited nature of NCCT in real clinical practice by systematically leveraging clinically co-occurring and complementary supervision, including CECT, radiology reports, and pathology reports, to enhance NCCT representations, while relying on NCCT alone at inference time. We believe this clinically motivated, NCCT-centered omni-pretraining formulation is itself an important contribution. (2) New training paradigm. Our training paradigm is neither simple joint training nor plain sequential training. Instead, it is designed to stably organize heterogeneous supervision, accumulate knowledge, and integrate it into a single model. Specifically, the progression from Stage 1 to Stage 4 is not a heuristic stacking of objectives, but follows a multi-dimensional increase in supervision difficulty: supervision becomes less directly grounded in the image, more semantically abstract, and more prone to optimization conflict. Based on this progression, later stages retain earlier objectives and progressively freeze shallow or intermediate representations to reduce interference with previously learned visual and structural knowledge and to mitigate forgetting. Compared with joint training, curriculum consolidation consistently improves both internal and external performance, for example increasing internal tumor segmentation from 56.76 to 63.83 Dice and external zero-shot T/N staging from 68.20/54.82 to 74.64/64.61. The stage-wise ablations and effective-rank analysis further show that retaining earlier objectives and progressive freezing reduce optimization interference and representation collapse. In this sense, the methodological novelty of our work lies not in any isolated module, but in a principled framework for ordering, accumulating, and stably consolidating heterogeneous supervision.

Q4. Code, model, and data availability.

Response: To improve reproducibility, we will release the code and pretrained model weights, and we have already provided the code and representative anonymized samples to the AC via an anonymous link. Regarding the dataset, Omni-CT10K contains retrospective clinical imaging data together with associated multimodal clinical information, and therefore cannot be made fully public because of patient privacy protections, institutional data governance, and IRB-related restrictions. Researchers may request access to anonymized data and supporting clinical information by contacting the corresponding author. Access will be granted subject to institutional approval, IRB approval where applicable, and a signed data-use agreement, and will be limited to non-commercial academic research. We will include a formal data availability statement in the revised manuscript to clearly describe this access process.

Detailed statistical distributions of the dataset are also provided.

Table R5. Patient-level distribution.

Characteristic Value 1 Value 2 Value 3 Value 4
Age <50: 1,820 50–64: 4,314 65–74: 3,101 ≥75: 1,356
Sex Male: 6,133 Female: 4,452 Other: 6 /

Table R6. Acquisition distribution.

Parameter Value 1 Value 2 Value 3 Value 4
Scanner manufacturer Philips: 4,718 Toshiba: 3,598 Siemens: 1,898 United Imaging: 377
Tube voltage <100 kVp: 28 100–119 kVp: 0 120 kVp: 10,547 >120 kVp: 16
Tube current <200 mA: 41 200–299 mA: 1,357 300–399 mA: 6,327 ≥400 mA: 2,866
CTDIvol <10 mGy: 53 10–14.9 mGy: 3,053 15–19.9 mGy: 7,469 ≥20 mGy: 16
Slice thickness ≤1 mm: 4,248 1.5–3 mm: 966 5 mm: 5,376 >5 mm: 1

Table R7. Radiology report statistics. Words are reported as mean / median.

Cohort Report words Extracted report words
Overall 167.1 / 162 29.3 / 25
CRC 171.9 / 168 43.9 / 42
Normal 164.4 / 159 20.8 / 14

Q5. Efficiency vs. performance trade-off.

Response: Table R8 compares the GPU hours and peak memory of RadOmni and joint training. The main computational cost lies in S1, which is shared by both strategies; thus, the relevant overhead comparison is for the post-S1 stages. Under our setting, RadOmni adds only 97 GPU hours over joint training, corresponding to about 12 extra wall-clock hours in our 8-GPU setup. RadOmni also has a lower peak memory footprint than joint training, because progressive freezing in S2–S4 reduces the number of trainable parameters. To contextualize this cost, we further report zero-shot generalization on the external ExtBenchB benchmark in addition to the internal ablation results. RadOmni shows consistent improvements on both internal tasks and the external benchmark, with especially notable gains on the external data. Overall, compared with joint training, RadOmni delivers stable internal and external performance gains at the cost of only 12 additional wall-clock hours. This overhead arises only during training; inference cost remains identical. We will add this efficiency analysis to the revised manuscript to better clarify the performance–computation trade-off.

Table R8. Computational cost comparison between joint training and RadOmni. We report stage-wise GPU hours and peak GPU memory (GB).

Metric Strategy S1 S2 S3 S4 Total/Peak
GPU Hours (H) Joint Training 882 / / 106 988
GPU Hours (H) RadOmni 882 4 91 104 1081
Peak Memory (GB) Joint Training 58.6 / / 78.8 78.8
Peak Memory (GB) RadOmni 58.6 4.9 61.2 57.6 61.2

Table R9. Zero-shot generalization on ExtBenchB.

Strategy Classification T staging N staging M staging
Joint Training 96.81 68.20 54.82 52.51
RadOmni 98.53 74.64 64.61 53.54
Imporovement +1.72 +6.44 +9.79 +1.03

Q6. Limitations.

Response: We thank the reviewer and agree that the limitations should be stated more explicitly. The current manuscript already discusses several limitations in the conclusion, but they are not organized under a dedicated “Limitations” heading and may therefore be easy to overlook. We will revise the paper to present them in a clearly marked Limitations section.

Authors · CommentOpenReview ↗

Thank you again for your thoughtful review and for recognizing the strong clinical motivation, the curriculum consolidation strategy, and the value of the Omni-CT10K dataset. We hope that our additional experiments on CT-RATE, PLCC, and TriALS, together with the clarifications regarding methodological contribution and computational efficiency, have addressed your concerns. With the discussion period nearing its conclusion, we would welcome any additional comments or suggestions. We would be happy to clarify any outstanding points before the discussion closes. Thank you again for your time and consideration.

Authors · CommentOpenReview ↗

We thank the reviewer for this suggestion. In addition to CT-RATE, we further evaluated RadOmni on the public Merlin benchmark [1], whose abdominal CT domain more closely matches our pretraining scope. Following the Merlin protocol, we evaluated zero-shot classification across 30 abdominal findings. The results are summarized in Table R3. RadOmni exceeds Merlin’s reported macro F1 by 6.07, providing complementary evidence from a large-scale public benchmark. We hope these additional results address the reviewer's concern regarding public-benchmark validation and transferability. We would welcome any opportunity to address reviewer's concerns before the discussion concludes. We sincerely appreciate your consideration of our rebuttal and new results.

Method Evaluation scope Macro F1 (%)
MERLIN 30 abdominal findings 74.10
RadOmni 30 abdominal findings 80.17
Improvement +6.07

Reference

[1] Blankemeier L, Kumar A, Cohen J P, et al. Merlin: a computed tomography vision–language foundation model and dataset[J]. Nature, 2026, 652(8112): 1318-1328.

Reviewer rboVOpenReview ↗
Rating
4/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The authors proposed RadOmni, formulates a curriculum consolidation learning strategy, in which knowledge is progressively injected according to optimization difficulty and knowledge level through four different stages. Associated with the training strategy, the authors curated Omni- CT 10k datasets, containing 10,591 samples, from multiple institutions, containing multi-modal supervision from clinical practice. The model was evaluated across four downstream tasks and showed to be performing better than existing different pre-training paradigms. The are pros and cons, please see the following sections in detail.

Strengths and weaknesses

Strength:

  1. The problem is well-motivated after observing current clinical limitation, and the proposals make sense to some extend. The amount of samples and the diversity of the data are relatively satisfactory in terms of NCCT Abdominal (or more specific colorectal cancer) domain only.
  2. The comprehensiveness of baseline comparisons and ablation studies are relatively satisfactory.
  3. The evaluation considered external center’s dataset, further showed the proposal’s generalizability in the scope.

Weakness:

  1. The dataset is only about colorectal cancer for non-contrast CT images, and it might be a bit exaggerated to state this dataset/proposal will work for other organs as well, like lungs, brains, etc.
  2. nnUNet is utilized as the backbone for vision part, maybe more modern architecture could be selected and tried. Also, some model training decisions (like stage 3&4 splits) are specifically designed for the “6-layer” nnUNet that the authors adopted. If using say “8-layer” nnUNet or some ViT-like structure, this mechanism might not work, or at least need re-design.
  3. More see in the Questions section.
Questions
  1. I’m curious on how the authors would try to “quantify” the difficulty increasing from the stage 1 to the stage 4, and how that leads to your training strategies to be different. Although I kind of understand there is a difficulty increasing, however they might not increase following similar logic. For example, stage 1-> stage 2 just more information required, and thus “more difficult”. But Stage 3 -> stage 4 (rad -> patho) might have information missed (since some signal won’t appear on CT but will available to pathologists), and thus another kind of “more difficult”.
  2. “Clinicians verify a randomly selected subset (20%) to ensure the quality and reliability of the extracted information” what are the metrics for clinicians to evaluate the “quality and reliability”?
  3. Will the dataset be publicly available? If yes, then when?
  4. I have a concern on the performance of the proposal (although it did good job on colorectal cancers) when it reaches other organs. How do the authors think? I understand no more experimentations could be done here given the complexity, but just want to hear your thoughts.
  5. I observed that in Stage 3, you freezed the first 2 layers of the nnUNet. and in Stage 4, you freeze the first 4 layers of the nnUNet. Is empirically tuned for the nnUNet backbone, or are there any other reasons why you did this with certain assumptions? What if you are now required to use “5-layer”/ “8-layer” nnUNet due to computational resources limitation, and how would you split the stages and why?
Limitations

Limitations were mentioned in their work reasonably, like computational capacity issue, clinicians' review capacity issues, etc.

Final justification

The authors have resolved my comments well. I would like to keep my rating.

Formatting concerns

N/A

2 comments
Authors · RebuttalOpenReview ↗
Rebuttal

Thank you for recognizing that our "problem is well-motivated after observing current clinical limitation" and that "the comprehensiveness of baseline comparisons and ablation studies are relatively satisfactory." We are particularly encouraged by acknowledgment that our external evaluation "showed the proposal's generalizability in the scope." Below, we address each of your concerns point by point.

Q1. The dataset is only about colorectal cancer for non-contrast CT images, and it might be a bit exaggerated to state this dataset/proposal will work for other organs.

Response: We agree with the reviewer that the current dataset and primary empirical validation are centered on colorectal cancer in non-contrast CT, and that broad applicability to other organs should not be overstated. Our intention was not to claim all-organ or all-disease coverage. Rather, “Omni” was intended to refer to the integration of multiple clinically co-occurring supervision sources. Moreover, although the training data are CRC-specific, the pretraining process may still capture general CT representations, including features related to lesions, organs, and surrounding context, which can serve as a useful initialization for downstream tasks in other organs. We agree that the current external results on other organs should be interpreted as evidence of transfer potential or initialization benefit, rather than conclusive proof of broad cross-organ generalization. We will revise the manuscript accordingly to temper these claims and avoid overgeneralization.

Q2. Why nnUNet was chosen as the visual backbone?

Response: We selected nnUNet as the visual backbone through a deliberate trade-off among architectural characteristics, task requirements, and computational cost. nnUNet is a strong and widely validated backbone for 3D medical image analysis, particularly for volumetric modeling, fine-grained local representation, and dense prediction. Since our pretraining framework is designed to support diverse downstream tasks, including classification, lesion segmentation, report generation, and pathology staging, the backbone must offer not only strong high-level semantic modeling but also reliable preservation of local lesion and anatomical details. We also considered transformer-based architectures such as ViT and Swin. However, in our current setting, which emphasizes 3D volumetric data, fine-grained lesion localization, and unified multi-task evaluation, nnUNet remains the more practical choice in terms of robustness, dense-prediction suitability, and computational efficiency. Thus, our adoption of nnUNet reflects a considered design choice for this setting.

Q3. Whether the Stage 3/4 freezing strategy is specifically designed for the 6-layer nnUNet?

Response: The decisions to freeze the first 2 layers in Stage 3 and the first 4 layers in Stage 4 are not hand-crafted rules specific to a “6-layer nnUNet.” Instead, they are guided by the semantic hierarchy of representations rather than absolute layer indices. We conceptually divide the encoder into shallow, middle, and deep parts: shallow layers capture low-level visual patterns, middle layers encode regional structures and semantics, and deeper layers represent more task-specific abstract semantics. Accordingly, we view the encoder as roughly consisting of an early one-third, a middle one-third, and a late one-third. Since Stage 3 introduces radiology-report supervision, which is semantically richer but still closely related to imaging findings, we freeze the shallow portion (the first one-third) to preserve generic visual and anatomical representations. Stage 4 introduces pathology supervision, which is more abstract and less directly grounded in image space, and is therefore more likely to interfere with previously learned representations. We thus freeze both the shallow and middle portions (the first two-thirds) to reduce optimization interference and mitigate forgetting.

Q4. How to "quantify" the difficulty increasing from the stage 1-4, and how that leads to the training strategies to be different.

Respose: We thank the reviewer for this important question. We believe that difficulty is not a single scalar quantity, and the increase in difficulty from Stage 1 to Stage 4 should be understood along multiple dimensions. Specifically, we characterize this progression from three perspectives. (1) The directness of supervision gradually decreases. Stage 1 MIM is fully grounded in pixel- and local-structure recovery from the same NCCT scan. Stage 2 still benefits from strong image-level correspondence through paired NCCT and CECT from the same patient. In contrast, Stage 3 uses radiology reports, which provide findings-level semantic supervision with weaker spatial grounding, while Stage 4 relies on pathology supervision, which is even more indirect and reflects staging semantics without explicit one-to-one correspondence in image space. (2) The semantic abstraction of supervision progressively increases, from structural priors, to anatomical and morpho-functional patterns, to report semantics, and finally to pathology-derived TNM evidence. (3) As heterogeneous supervision is added, the risk of optimization conflict also increases, since later high-level semantic objectives are more likely to interfere with earlier visual and structural representations.

Because difficulty increases in this multi-dimensional sense, our training strategy also changes by stage. Early stages use more direct and spatially grounded objectives to build stable visual and anatomical representations. Later stages retain earlier objectives and progressively freeze shallow or intermediate layers to reduce optimization interference and mitigate forgetting. In this sense, our staged training is not simply ordered by “more information,” but by a progression from direct to indirect supervision, from low-level to abstract semantics, and from weaker to stronger optimization conflict.

Q5. “Clinicians verify a randomly selected subset (20%) to ensure the quality and reliability of the extracted information” what are the metrics for clinicians to evaluate the “quality and reliability”.

Response: We thank the reviewer for this question. Here, “quality and reliability” were assessed by clinicians using two criteria: (1) faithfulness, i.e., whether the extracted text introduced any clinically relevant information not present in the original report; and (2) coverage, i.e., whether all colorectal-related descriptions in the original report were retained. We randomly sampled 2,106 reports (20%) and asked a radiologist to manually compare the extracted text against the original reports using these two criteria. Among them, 2,105 reports (99.95%) satisfied faithfulness, and 2,094 (99.43%) satisfied coverage; overall, 2,094 reports (99.43%) satisfied both criteria. These results indicate that the extraction process is highly accurate, with almost no clinically relevant information lost or distorted. We will clarify this evaluation protocol in the revised manuscript.

Table R1. Clinician evaluation of extraction quality on a randomly sampled 20% subset.

Evaluation Criterion Pass Fail Pass Rate
Faithfulness 2,105 1 99.95%
Coverage 2,094 12 99.43%
All two criteria 2,094 12 99.43%

Q6: Code, model, and data availability.

Response: To improve reproducibility, we will release the code and pretrained model weights, and we have already provided the code and representative anonymized samples to the AC via an anonymous link. Regarding the dataset, Omni-CT10K contains retrospective clinical imaging data together with associated multimodal clinical information, and therefore cannot be made fully public because of patient privacy protections, institutional data governance, and IRB-related restrictions. Researchers may request access to anonymized data and supporting clinical information by contacting the corresponding author. Access will be granted subject to institutional approval, IRB approval where applicable, and a signed data-use agreement, and will be limited to non-commercial academic research. We will include a formal data availability statement in the revised manuscript to clearly describe this access process.

Authors · CommentOpenReview ↗

Thank you again for your thoughtful review and for recognizing that the problem is well-motivated, the baseline comparisons and ablation studies are comprehensive, and the external evaluation provides evidence of generalizability within the studied scope. We hope that our clarifications regarding the scope of the claims, backbone selection, staged training strategy, supervision difficulty, and clinician-based quality assessment have addressed your concerns.

Reviewer z3LgOpenReview ↗
Rating
3/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
2/4
Originality
3/4
Contribution type
general
Ethical concerns
CLEAR MAJOR CONCERN: Check this box if there is a clear, major concern for which you do not need further clarifications. Detail the concern in the Strengths and Weaknesses section. Use another option below if you would benefit from a consultation with an expert.
Read review
Summary

The manuscript proposes a staged encoder pretraining strategy for Non-contrast CT (NCCT) images. During the four stages, additional information is injected (contrast-enhanced CT scans (CECT), radiology reports, pathology reports). All CT scans are colorectal cancer (CRC) cases; the dataset Omni-CT10K would be a valuable ressource for the medical imaging community.

Details & Typos Abstract: TNM is not defined Section 3: "A randomly subset is .."

Strengths and weaknesses

Strengths:

  • Interesting and relevant problem is tackled
  • Curation of a very interesting dataset was done
  • Staged information integration is a clear methodology

Weaknesses:

  • Practical/clinical application scenario is not obvious or at least not fully discussed.
  • All the experimental evidence depends on non-disclosed data and code so the results are hard to reproduce
  • The registration between CECT and NCCT data is crucial for stage 2 to be meaningful.
  • The paper title and the dataset title suggest a much broader scope than the manuscript actually covers. Non-Contrasted colorectal cancer CT scans versus "RadOmni". The names could be sharpened.

Details & Typos

  • Abstract "TNM" is not defined
  • Section 3: "A randomly subset is .."

Concerns:

  • NeurIPS Paper Checklist: Question 4 was not answered correctly. Questions 15, 16 were answered with N/A.
  • Ethics: No details about IRB approval are provided. Patient data anonymisation strategy is unclear.
Questions
  • Some details about the data acquisition are missing: Are the NCCT scans from the same clinical exam? Why are the contrasted scans missing in the first place (technical reasons, clinical reasons)?
  • What is the envisaged deployment strategy of the foundation model?
  • There are some details about the registration (phase 2) missing: What happens if issues occur? How is a registration issue detected/monitored in the first place?
Limitations

yes

Formatting concerns

None

2 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We are grateful for your recognition that "interesting and relevant problem is tackled", "curation of a very interesting dataset was done", and "staged information integration is a clear methodology". We deeply appreciate your acknowledgment that Omni-CT10K "would be a valuable ressource for the medical imaging community". Below, we address each of your concerns point by point.

Q1: Practical/clinical application scenario and deployment strategy of the foundation model.

Response: We thank the reviewer for this important point. RadOmni is designed as an NCCT-centered foundation model that leverages complementary information available during routine care, such as CECT, radiology reports, and pathology reports, to learn stronger NCCT representations. It is not intended as a standalone end system that replaces the full diagnostic workflow, but rather as a pretrained backbone that can be finetuned for multiple downstream clinical applications. Using colorectal cancer as a representative use case, the model can support screening, triage, lesion localization, CT report drafting, and pathology-related staging prediction after task-specific adaptation, corresponding to the four downstream tasks studied in this work. We will revise the manuscript to make these deployment scenarios explicit and to better connect them to the four evaluated tasks.

Q2: Code, model, and data availability.

Response: To improve reproducibility, we will release the code and pretrained model weights, and we have already provided the code and representative anonymized samples to the AC via an anonymous link. Regarding the dataset, Omni-CT10K contains retrospective clinical imaging data together with associated multimodal clinical information, and therefore cannot be made fully public because of patient privacy protections, institutional data governance, and IRB-related restrictions. Researchers may request access to anonymized data and supporting clinical information by contacting the corresponding author. Access will be granted subject to institutional approval, IRB approval where applicable, and a signed data-use agreement, and will be limited to non-commercial academic research. We will include a formal data availability statement in the revised manuscript to clearly describe this access process.

Q3: The registration between CECT and NCCT data is crucial for stage 2 to be meaningful.

Response: We agree with the reviewer that registration quality is critical for Stage 2. Our NCCT-CECT pairs come from the same patient within the same examination, providing a strong anatomical basis for cross-phase correspondence. Before applying cross-phase representation alignment, we registered CECT to NCCT using the established methods in Refs. [35,36] and quantitatively assessed registration quality using MI, NMI, SSIM, and anatomical overlap. As shown in Appendix Table 9, registration consistently improves all metrics, with NMI increasing from 1.15 to 1.24, MI from 0.87 to 1.29, SSIM from 0.43 to 0.63, and TotalSegmentator-derived colon-mask Dice from 71.41% to 89.81%. These complementary intensity- and anatomy-based measurements indicate reliable correspondence at the cohort level. Moreover, cross-phase supervision is applied only when valid paired data and anatomical correspondence are available, which helps mitigate the effect of potential registration errors. We will clarify the registration protocol, quality monitoring, and the applicability conditions of cross-phase supervision in the revised manuscript.

Q4. The paper title and the dataset title suggest a much broader scope than the manuscript actually covers. Non-Contrasted colorectal cancer CT scans versus "RadOmni". The names could be sharpened.

Response: We recognize that the current title and dataset naming may suggest a broader scope than what is empirically validated. While the proposed framework is general in formulation, the data used in this work and the primary empirical validation are centered on CRC-focused NCCT. In this context, “Omni” was intended to refer to the integration of multiple clinically co-occurring supervision sources, rather than all-organ or all-disease coverage. To avoid overstatement, we will sharpen the naming in the revision, for example by adopting a more CRC-specific method/dataset name such as CRCOmni or CRCFM, and revise the title and corresponding descriptions accordingly.

Q5. Details about the data acquisition: Are the NCCT scans from the same clinical exam? Why are the contrasted scans missing in the first place?

Response: We thank the reviewer for this question. When both NCCT and CECT are available in Omni-CT10K, they come from the same patient and the same clinical examination. In routine CT workflows, CECT requires contrast injection and is typically preceded by NCCT, so patients with CECT usually also have a corresponding NCCT. In contrast, not all patients require contrast-enhanced imaging; whether CECT is acquired is mainly determined by clinical indication and workflow, rather than technical missingness. As a result, some cases have NCCT only. This real-world acquisition pattern is one of the motivations for our NCCT-centered foundation model, and we will clarify it in the revised manuscript.

Other concerns

Response: Q15 (IRB approval) was incorrectly marked as N/A. This study uses retrospective clinical data under institutional ethical approval; due to double-blind review, the current submission omits identifiable institutional details and the approval number. All imaging and associated clinical text data were de-identified before dataset curation and model development, and were used under institutional data-governance requirements. We will provide the full ethics statement and approval details in the final version. Regarding Q16, LLM usage is described in Appendix E, and its N/A marking in the checklist was a typo.

Authors · CommentOpenReview ↗

Thank you again for your thoughtful review and for recognizing the relevance of the problem, the value of Omni-CT10K, and the staged information integration methodology. We hope that our clarifications regarding clinical deployment, registration quality, data and code availability, study scope, and ethical considerations have addressed your concerns. As the discussion period is approaching its end, we would greatly appreciate any further feedback, even if brief. If any concerns remain, we would be grateful to hear them and will do our best to provide further clarification during the remaining discussion period. Thank you again for your time and consideration.

Comments on the paper

3 comments
Authors · CommentOpenReview ↗

Response to Meta Review

We thank the AC for the summary and suggestions.

Rationale for ordering of the training stages. The stage ordering is not arbitrary, which follows two coupled principles (we will make explicit in Sec. 2.1). First, the ordering reflects the clinical evidence hierarchy along the diagnostic workflow described in our Introduction: a radiologist first reads the structural information intrinsic to the NCCT image itself, then consults contrast-enhanced CT for morpho-functional cues, then composes a radiology report that conveys high-level imaging findings, and finally, when a definitive diagnosis is required, obtains microscopic evidence through pathology examination. Each modality is progressively more abstract and more diagnostically specific, so we inject supervision in this order. Second, this ordering further follows a curriculum of increasing optimization difficulty, advancing from dense low-level visual reconstruction (MIM) toward sparse, weakly-grounded high-level alignment (report/pathology). Without stable structural and anatomical priors in place, these sparse high-level objectives destabilize optimization, as our ablations confirm. Empirically, Table 4 shows that the individual stages provide heterogeneous and complementary knowledge, and Table 5 further demonstrates that our ordered accumulation yields the largest gains across the different downstream tasks, compared with joint optimization or plain sequential training.

Generalizability to other organs. We have added experiments on CT-RATE (Chest) and public multiphase CT datasets PLCC (Liver & Liver lesion) and TriALS (Liver lesion), where RadOmni pretraining consistently improves performance. At the same time, we agree that our current data construction and primary pretraining setting remain centered on CRC-focused NCCT. We will therefore state cross-organ generalization more cautiously and tone down the related claims in the revised manuscript.

Error propagation across stages. The concern about error propagation is closely tied to two specific worries raised by the reviewers: Reviewer z3Lg raised concerns about the registration quality between NCCT and CECT, and Reviewer rboV raised concerns about the reliability of extracting key fields from the reports. We have addressed both of these under the corresponding questions below (see our responses to z3Lg and rboV). Beyond these, we would like to clarify a more fundamental point. Each stage learns heterogeneous knowledge from a distinct modality rather than refining the output of the previous stage. Consequently, although RadOmni is a sequential pre-training framework, it does not suffer from error propagation.

In addition, we have also strengthened the discussion on reproducibility, ethics, and efficiency. We will release the code and pretrained weights, and provide the relevant materials via an anonymous link the AC committee.

Authors · CommentOpenReview ↗

Summary of Key Rebuttal Updates

Dear AC and Reviewers,

Thank you for the constructive feedback. We briefly summarize how the rebuttal addresses the main concerns:

Stage ordering and consolidation strategy (rboV, Gq9s). We clarified that the stages progress from spatially grounded supervision toward increasing semantic abstraction: NCCT structure → registered paired CECT → radiology reports → pathology-derived TNM supervision. Retaining earlier objectives and progressively freezing lower-level representations mitigates optimization interference; compared with joint training, tumor Dice improves from 56.76 to 63.83.

Cross-organ generalizability (rboV, Gq9s). We added public evaluations on CT-RATE (Chest), Merlin (Abdomen), PLCC (paired Liver Lesions), and TriALS (paired Liver Lesions). RadOmni improves CT-RATE F1/AUC from 75.9/79.0 to 77.0/79.8, Merlin F1 from 74.10 to 80.17 and NCCT lesion Dice by 3.04 on PLCC and 5.19 on TriALS. We will nevertheless narrow the claims to transferability rather than universal generalization.

Registration and supervision quality (z3Lg, rboV). For same-examination NCCT–CECT pairs, registration improves colon-mask Dice from 71.41% to 89.81%, with consistent improvements in MI, NMI, and SSIM. A radiologist also evaluated 2,106 randomly sampled report extractions, of which 99.43% satisfied both faithfulness and coverage.

Reproducibility and ethics(z3Lg, Gq9s). We provided anonymous code, representative de-identified samples, dataset statistics, and will release pretrained weights. The anonymized materials have been submitted to the AC committee.

We would appreciate any feedback on whether these additions resolve the main concerns or whether further clarification would be helpful.

Authors · CommentOpenReview ↗

Final Author Summary for the AC

Dear AC,

As the discussion concludes, we respectfully summarize our rebuttal for your final assessment. The reviewers consistently recognized the framework’s strong clinical motivation, valuable data curation, comprehensive experiments, and technical soundness. The remaining concerns focused on strengthening the methodological explanation and public validation, while clarifying the scope, reproducibility, data availability, and ethical documentation.

In Response to Meta Review, we provided a dedicated response to the AC’s three highlighted issues concerning stage ordering, cross-organ generalizability, and error propagation. The main updates are further consolidated in Summary of Key Rebuttal Updates. Specifically, we added evaluations on four public benchmarks while narrowing our claims to the validated scope; clarified the clinical and optimization rationale for stage ordering, knowledge consolidation, and error control; and provided the AC committee with anonymized code, representative samples, and dataset statistics. We also committed to publicly releasing the code and pretrained weights, disclosing the full IRB approval details in the final manuscript, and enabling controlled academic access to the de-identified data.

Throughout the rebuttal period, we have actively engaged with all reviewers concern through rebuttals, additional experiments, quantitative quality controls, follow-up clarifications, and reproducibility materials. We believe these efforts could address the three issues highlighted in the meta-review and the principal concerns raised by the reviewers. We respectfully hope that this substantially strengthened evidence will be considered in the final assessment.

Thanks,

The Authors

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.