Reinforcement learning enhanced flow matching for reference-based tumor generation on unpaired CT images
Xiaoxuan Gong, Zhilin Zheng, Tiancheng Lin, Qinji Yu, Jianpeng Zhang, Shaoteng Zhang, Kai Cao, Xiaoli Yin, Yu Shi, Jie Ma, Ling Zhang, Yingda Xia
NeurIPS 2026
Abstract. The success of deep learning in medical image analysis is often hindered by the long-tail distribution of disease cases, where rare or early-stage tumors are critically under-represented. While controllable synthesis offers a potential solution, existing methods suffer from a \textit{specification bottleneck}, as low-dimensional signals like text or binary masks fail to capture complex textures and morphological variations. In this paper, we propose an exemplar-driven synthesis framework that utilizes real tumor samples as high-dimensional templates to enable precise, case-specific generation. To the best of our knowledge, this is the first work to introduce reinforcement learning (RL) into the field of 3D medical image generation, called MedGRPO. We formulate the unpaired tumor synthesis task as a constrained trajectory optimization problem and leverage Flow-GRPO to find an optimal generation path. By designing a multi-objective reward system encompassing texture, shape, and semantic consistency, our model effectively balances pathological fidelity with anatomical coherence without requiring paired supervision. Rigorous evaluations across four major tumor types and the external AbdomenAtlas 2.0 dataset demonstrate that our method produces high-fidelity synthetic data that significantly enhances the performance of downstream diagnostic models.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:50 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
This paper proposes MedGRPO, an exemplar-driven framework for reference-based tumor generation in CT images. The method first trains a flow-matching model on paired data and then applies reinforcement learning with multi-objective rewards to improve exemplar-guided tumor synthesis on unpaired CT images. Experiments on four tumor types and the external AbdomenAtlas 2.0 dataset suggest improvements in both synthesis quality and downstream tumor segmentation.
---------------Initial Meta-review-------------- The reviewers appreciated the importance of addressing data scarcity for rare tumors and found the exemplar-driven formulation to be a meaningful alternative to conventional text- or mask-based conditioning. They also found the two-stage supervised learning and reinforcement learning framework to be technically well motivated, and appreciated the evaluation on an external dataset to assess downstream generalization.
Meanwhile, there are also important questions.
First, the motivation for introducing reinforcement learning could be better justified. While the paper argues that reinforcement learning enables optimization in the absence of paired supervision, it remains unclear why trajectory-level policy optimization is the most appropriate framework for this problem, and what advantages it provides over alternative optimization strategies for enforcing the proposed shape, texture, and semantic objectives.
Second, the downstream evaluation should be strengthened. While the paper shows that MedGRPO improves downstream segmentation compared with training on real data alone, it does not compare downstream performance against models augmented with synthetic data generated by competing synthesis methods.
Third, the current evaluation relies primarily on FID and automated metrics, together with qualitative examples, making it difficult to clearly assess the contribution of the RL stage. Additional independent evaluation, stronger statistical analysis, or clearer comparisons between the supervised and RL stages would better support the claimed improvements.
Fourth, several implementation details and reproducibility require clarification. For example, the reviewers requested more information about the pretrained segmentation model used in the reward function, statistical significance of the reported results, computational cost, and the limitations associated with the private training dataset.
Fifth, since only the tumor region is intended to be modified, quantitative evaluation of background preservation or anatomical consistency outside the synthesized lesion would strengthen the practical validity of the approach.
Please address the following points in the rebuttal:
(1) Please better justify why reinforcement learning is the appropriate optimization framework for this problem. In particular, explain why the proposed objectives are better optimized using trajectory-level policy optimization than direct differentiable losses or other non-RL training strategies in the unpaired exemplar-guided synthesis setting.
(2) Strengthen the downstream evaluation by comparing against competing synthesis methods under the same downstream segmentation protocol.
(3) Provide stronger evidence that the RL stage improves realism and controllability, such as clearer quantitative and qualitative comparisons, stronger statistical analysis, and clarification of the segmentation reward.
(4) Clarify the implementation details, including the training of the reward models, computational cost, statistical reporting, and limitations related to the private dataset.
(5) Please provide quantitative evidence that the proposed method preserves the surrounding anatomy outside the synthesized tumor region.
(6) Better position the work with respect to prior RL-based medical image synthesis methods and clarify the claimed novelty where appropriate.
-------------Final Meta-review--------------
I have reviewed the authors' rebuttal, the discussion, and the reviewers' final assessments. The rebuttal substantially addresses the main concerns raised in the initial meta-review. The authors provide stronger justification for trajectory-level reinforcement learning, add same-protocol downstream comparisons, repeated experiments, a no-RL ablation, and additional radiologist evaluation. Importantly, the concern regarding preservation of non-tumor anatomy was directly addressed through a quantitative analysis on 1,000 CT volumes, showing high PSNR and SSIM in the background region outside the synthesized tumor.
The reviewers responded positively to the rebuttal, with all final assessments on the acceptance side. Some limitations remain, such as the non-uniform benefit of the RL stage across organs and metrics, claim calibration, and reproducibility constraints. Nevertheless, I find that the rebuttal has sufficiently addressed the major concerns and that the remaining limitations do not outweigh the paper's strengths. I therefore recommend accepting the paper.
Final justification
I have reviewed the authors' rebuttal, the discussion, and the reviewers' final assessments. The rebuttal substantially addresses the main concerns raised in the initial meta-review. The authors provide stronger justification for trajectory-level reinforcement learning, add same-protocol downstream comparisons, repeated experiments, a no-RL ablation, and additional radiologist evaluation. Importantly, the concern regarding preservation of non-tumor anatomy was directly addressed through a quantitative analysis on 1,000 CT volumes, showing high PSNR and SSIM in the background region outside the synthesized tumor.
The reviewers responded positively to the rebuttal, with all final assessments on the acceptance side. Some limitations remain, such as the non-uniform benefit of the RL stage across organs and metrics, claim calibration, and reproducibility constraints. Nevertheless, I find that the rebuttal has sufficiently addressed the major concerns and that the remaining limitations do not outweigh the paper's strengths. I therefore recommend accepting the paper.
Read meta-review
Meta-review
This paper proposes MedGRPO, an exemplar-driven framework for reference-based tumor generation in CT images. The method first trains a flow-matching model on paired data and then applies reinforcement learning with multi-objective rewards to improve exemplar-guided tumor synthesis on unpaired CT images. Experiments on four tumor types and the external AbdomenAtlas 2.0 dataset suggest improvements in both synthesis quality and downstream tumor segmentation.
---------------Initial Meta-review-------------- The reviewers appreciated the importance of addressing data scarcity for rare tumors and found the exemplar-driven formulation to be a meaningful alternative to conventional text- or mask-based conditioning. They also found the two-stage supervised learning and reinforcement learning framework to be technically well motivated, and appreciated the evaluation on an external dataset to assess downstream generalization.
Meanwhile, there are also important questions.
First, the motivation for introducing reinforcement learning could be better justified. While the paper argues that reinforcement learning enables optimization in the absence of paired supervision, it remains unclear why trajectory-level policy optimization is the most appropriate framework for this problem, and what advantages it provides over alternative optimization strategies for enforcing the proposed shape, texture, and semantic objectives.
Second, the downstream evaluation should be strengthened. While the paper shows that MedGRPO improves downstream segmentation compared with training on real data alone, it does not compare downstream performance against models augmented with synthetic data generated by competing synthesis methods.
Third, the current evaluation relies primarily on FID and automated metrics, together with qualitative examples, making it difficult to clearly assess the contribution of the RL stage. Additional independent evaluation, stronger statistical analysis, or clearer comparisons between the supervised and RL stages would better support the claimed improvements.
Fourth, several implementation details and reproducibility require clarification. For example, the reviewers requested more information about the pretrained segmentation model used in the reward function, statistical significance of the reported results, computational cost, and the limitations associated with the private training dataset.
Fifth, since only the tumor region is intended to be modified, quantitative evaluation of background preservation or anatomical consistency outside the synthesized lesion would strengthen the practical validity of the approach.
Please address the following points in the rebuttal:
(1) Please better justify why reinforcement learning is the appropriate optimization framework for this problem. In particular, explain why the proposed objectives are better optimized using trajectory-level policy optimization than direct differentiable losses or other non-RL training strategies in the unpaired exemplar-guided synthesis setting.
(2) Strengthen the downstream evaluation by comparing against competing synthesis methods under the same downstream segmentation protocol.
(3) Provide stronger evidence that the RL stage improves realism and controllability, such as clearer quantitative and qualitative comparisons, stronger statistical analysis, and clarification of the segmentation reward.
(4) Clarify the implementation details, including the training of the reward models, computational cost, statistical reporting, and limitations related to the private dataset.
(5) Please provide quantitative evidence that the proposed method preserves the surrounding anatomy outside the synthesized tumor region.
(6) Better position the work with respect to prior RL-based medical image synthesis methods and clarify the claimed novelty where appropriate.
-------------Final Meta-review--------------
I have reviewed the authors' rebuttal, the discussion, and the reviewers' final assessments. The rebuttal substantially addresses the main concerns raised in the initial meta-review. The authors provide stronger justification for trajectory-level reinforcement learning, add same-protocol downstream comparisons, repeated experiments, a no-RL ablation, and additional radiologist evaluation. Importantly, the concern regarding preservation of non-tumor anatomy was directly addressed through a quantitative analysis on 1,000 CT volumes, showing high PSNR and SSIM in the background region outside the synthesized tumor.
The reviewers responded positively to the rebuttal, with all final assessments on the acceptance side. Some limitations remain, such as the non-uniform benefit of the RL stage across organs and metrics, claim calibration, and reproducibility constraints. Nevertheless, I find that the rebuttal has sufficiently addressed the major concerns and that the remaining limitations do not outweigh the paper's strengths. I therefore recommend accepting the paper.
Final justification
I have reviewed the authors' rebuttal, the discussion, and the reviewers' final assessments. The rebuttal substantially addresses the main concerns raised in the initial meta-review. The authors provide stronger justification for trajectory-level reinforcement learning, add same-protocol downstream comparisons, repeated experiments, a no-RL ablation, and additional radiologist evaluation. Importantly, the concern regarding preservation of non-tumor anatomy was directly addressed through a quantitative analysis on 1,000 CT volumes, showing high PSNR and SSIM in the background region outside the synthesized tumor.
The reviewers responded positively to the rebuttal, with all final assessments on the acceptance side. Some limitations remain, such as the non-uniform benefit of the RL stage across organs and metrics, claim calibration, and reproducibility constraints. Nevertheless, I find that the rebuttal has sufficiently addressed the major concerns and that the remaining limitations do not outweigh the paper's strengths. I therefore recommend accepting the paper.
1 comment
- Rating
- 5/6
- Confidence
- 3/5
- Quality
- 4/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The work proposes a unique method in inpainting tumors to CT images through reinforcement learning(Flow-GRPO). Their method utilizes supervised training first, creating an initial result, and uses RL to further enhance the result to match the characteristics of the reference tumor. They show that their method has more realistic features compared to other inpainting models, shown through qualitative and quantitative(Frechet inception distance) results.
Strengths and weaknesses
The idea of using Flow-GPRO as a refinement after a paired supervised model for tumor synthesis is sound and appropriate. They are open about the methods used, but does not provide enough information to justify that they have provided 'how to use the code' without the github repository. The figures and tables seem to require some fixes.
- Figure 3 shows the tumor via overlap of green, which is not ideal to see the texture and realistic feature of the tumor as they claim. I recommend a bounding box or a boundary.
- When qualitatively comparing the methods, I suppose it was done on the same base image. However, without the base image provided, it is hard for the reader to evaluate the exact effects the method had on the image.
- Since the work's non-RL version model has been included in the qualitative results for ablation study, it would be natural to have it in table 1 as well, especially since evaluation metrics for realistic synthesis are still on dispute.
I am not sure if their claim of this being the sole case of using reinforcement learning on medical image synthesis is correct. See [1] for example. I would suggest changing the claim to the first case of inpainting, or first case in tumor synthesis or first case of Flow-GPRO in medical imaging.
Overall, it is innovative and meaningful work, but there should be some small changes in the presentation of the results.
[1] Xu, Chenchu, et al. "Synthesis of gadolinium-enhanced liver tumors on nonenhanced liver MR images using pixel-level graph reinforcement learning." Medical image analysis 69 (2021): 101976.
Questions
Outside of medical imaging, have you seen any cases of Flow-GPRO used? It is reasonable to assume this kind of shape/texture refinement is beneficial in multiple areas. Or, if there were post-process refinement techniques like this but not using Flow-GPRO, it is also worth mentioning.
I am open to increasing clarity scores if the points in limitations are addressed.
Limitations
- Figure 3 shows the tumor via overlap of green, which is not ideal to see the texture and realistic feature of the tumor as they claim. I recommend a bounding box or a boundary.
- When qualitatively comparing the methods, I suppose it was done on the same base image. However, without the base image provided, it is hard for the reader to evaluate the exact effects the method had on the image.
- Since the work's non-RL version model has been included in the qualitative results for ablation study, it would be natural to have it in table 1 as well, especially since evaluation metrics for realistic synthesis are still on dispute.
- I am not sure if their claim of this being the sole case of using reinforcement learning on medical image synthesis is correct. See [1] for example. I would suggest changing the claim to the first case of inpainting, or first case in tumor synthesis or first case of Flow-GPRO in medical imaging.
Final justification
Comments about the table and the phrasing has been addressed. I understand that the figures might be changed later. I have seen other reviewers' comments, and I have decided the strength provided by other reviewers are valid yet not enough to change the review score, and major weaknesses have been answered.
Formatting concerns
I do not see any formatting issues
1 comment
Rebuttal
Thank you for recognizing and appreciating our work. We also sincerely appreciate your valuable suggestions for improving our paper. We will address your concerns one by one as follows:
For weakness 1 and limitation 1:
Thank you for your helpful suggestion. Due to the page limitation during the submission stage, we had to reduce the size of the figures to reserve sufficient space for the main text. In the camera-ready version, we will enlarge Figure 3 and follow your suggestion by using bounding boxes to highlight the tumor regions instead of green masks, which may obscure the underlying image textures.
For weakness 2 and limitation 2:
Thank you for pointing out this issue. Similarly, in the revised version, we will include the original input image (clean CT) in Figure 2, allowing readers to more clearly observe the changes in the tumor regions introduced by different methods.
For weakness 3 and limitation 3:
Thank you for pointing out this issue. We have added the MedGRPO (no-RL) comparison experiment to Table 1 in the revised version. Furthermore, to make the experimental results more convincing, we conducted repeated experiments with five different random seeds and report the mean and standard deviation as follows:
4-cancer dataset:
| method/organ | Breast | Kidney | Liver | Pancreas |
|---|---|---|---|---|
| SynTumor | - | 70.04±0.34 | 36.81±0.27 | 34.87±0.21 |
| LeFusion | 196.08±2.80 | 79.78±0.50 | 68.75±0.67 | 39.98±0.40 |
| LesionDiffusion | 97.38±0.98 | 79.93±0.13 | 36.17±0.34 | 42.06±0.26 |
| DiffTumor | - | 67.50±0.40 | 36.94±0.53 | 39.72±0.21 |
| FreeTumor | - | 141.71±0.31 | 115.68±0.17 | 109.29±0.06 |
| MAISI | - | - | 44.35±0.32 | 90.42±0.26 |
| MedGRPO (no-RL) | 64.67±1.71 | 59.24±0.67 | 30.71±0.37 | 27.71±0.23 |
| MedGRPO | 57.67±1.04 | 50.66±0.31 | 25.21±0.29 | 23.55±0.51 |
Atlas dataset:
| method/organ | Kidney | Liver | Pancreas |
|---|---|---|---|
| SynTumor | 94.23±0.64 | 7.95±0.10 | 13.92±0.10 |
| LeFusion | 104.64±0.15 | 27.55±0.38 | 10.55±0.13 |
| LesionDiffusion | 98.83±0.17 | 10.84±0.15 | 13.65±0.30 |
| DiffTumor | 70.16±0.59 | 9.68±0.35 | 10.17±0.14 |
| FreeTumor | 195.77±0.27 | 82.82±0.08 | 75.73±0.06 |
| MAISI | - | 20.97±0.14 | 52.50±0.22 |
| MedGRPO (no-RL) | 90.51±0.45 | 4.95±0.05 | 1.60±0.03 |
| MedGRPO | 83.35±0.47 | 3.27±0.03 | 2.30±0.06 |
By comparing the results before and after RL fine-tuning, we can observe that the GRPO-based reinforcement learning post-training strategy indeed brings a significant improvement in the overall realism of the generated images.
For weakness 4 and limitation 4:
Once again, thank you for your careful reading and valuable suggestions. After careful consideration, we have decided to revise the statement to “the first work to apply reinforcement learning for tumor generation” to avoid any potential ambiguity.
For question:
Flow-GRPO was originally proposed as a post-training method for natural image generation models, with the goal of improving abstract objectives such as aesthetic quality and text–image alignment. In principle, any Flow Matching-based generative model can adopt this framework for reinforcement learning post-training to optimize objectives that are difficult to address through conventional supervised learning.
In fact, Flow-GRPO is not the only available option for post-training Flow Matching-based models. For example, in our early experiments, we also explored DiffusionNFT [1]. However, because it achieved slightly inferior performance compared with Flow-GRPO, it was not selected for our final framework. Since the primary goal of this work is to develop a high-performance tumor generation method rather than systematically compare different reinforcement learning algorithms, we did not include this comparison in the original manuscript.
Nevertheless, as you suggested, we will add a discussion of alternative reinforcement learning approaches to the Discussion section of the revised manuscript.
Reference
[1] Zheng K, Chen H, Ye H, et al. Diffusionnft: Online diffusion reinforcement with forward process[J]. arXiv preprint arXiv:2509.16117, 2025.
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 2/4
- Clarity
- 1/4
- Significance
- 4/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This work addresses the challenge of data scarcity in medical AI, Specifically the long-tail distribution of rare and early-stage tumors in 3D CT imaging. The authors propose MedGRPO, an exemplar-driven synthesis framework that uses real tumor samples as high-dimensional templates, and introduces reinforcement learning (via Flow-GRPO) into 3D medical image generation for the first time.
This is timely research and the community's growing interest in bringing RL into pathology-aware data generation makes this a well-positioned contribution. However, the paper's qualitative evidence does not yet match its ambition. It remains difficult to visually assess whether the proposed methodology yields substantial improvement, primarily because the chosen tumor types are small and low-contrast, and the figures are too densely packed to allow meaningful perceptual evaluation. The paper would benefit greatly from dedicating a prominent, high-resolution figure solely to what changes after RL; showing exemplar, pre-RL, and post-RL outputs side by side as large ROI crops.
The paper introduces two intertwined contributions (exemplar-driven conditioning and RL optimization). However, never cleanly separates their effects. Adding a MedGRPO (no-RL) row to Table 2 would allow direct quantification of what RL alone contributes to downstream segmentation performance.
Strengths and weaknesses
Strength:
-
- Novelty of the RL Integration Applying GRPO to flow matching in the 3D medical imaging domain is genuinely novel. The formulation of unpaired tumor synthesis as a constrained trajectory optimization problem is well-motivated and technically sound.
-
- Multi-Objective Reward Design The three-reward system (texture via Bhattacharyya distance, shape via triplet-loss contrastive learning, segmentation via pretrained network) is well-constructed.
-
-
- Downstream Validation Evaluating on the external AbdomenAtlas 2.0 dataset as an OOD benchmark is methodologically rigorous.
-
Strength:
- Visualization Quality This is the most significant presentation issue. The figures are far too small and densely packed, making qualitative evaluation essentially impossible for reviewers:
- Comparison (Visually): The comparison between MedGRPO (no-RL) vs. MedGRPO is arguably the most important ablation in the paper, yet it receives no dedicated close-up visualization. A reader cannot verify from the figures alone that RL meaningfully improves textural realism.
- Computational Cost Over 4,200 GPU hours on 32 H20 GPUs is a substantial cost.
- The paper evaluates on liver, kidney, pancreas, and breast tumors (producing small, low-contrast lesions in CT imaging). However, the consequence is that the synthetic tumor is essentially invisible, and reader can not perform any quality assessment (There are better dataset such as AutoPET, GBM tumor, Colorectal Liver Metastases)
Questions
- What specifically improves after RL, and can this be shown visually at sufficient resolution?
- Can the authors add a MedGRPO (no-RL) row?
- How does MedGRPO perform on more visually prominent tumor types?
- What is the inference time per case, and how does the method scale?
Limitations
The authors acknowledge limitations around modality scope (CT only, four organ types) However I see several:
- The paper relies entirely on automated metrics (FID, DSC) without any radiologist evaluation of synthetic tumor realism.
- The exemplar-driven approach assumes that a suitable real sufficient tumor exemplar is available at inference time.
- 4,200+ GPU hours on 32 H20 GPUs is a significant barrier.
Final justification
- To AC: I have updated the contribution category to “General.”
- The authors have generally addressed my comments well. I particularly appreciate the inclusion of radiologists to evaluate the quality of the generated images.
- However, the claimed qualitative visual improvement is actually difficult to assess objectively (and the new table shows very slight improvements). I have therefore updated my score to Borderline Accept. I would like to express my thought that the study could have been more interesting and persuasive if the proposed method had been evaluated on a more complex task than small-tumor synthesis, where the effect of RL-based fine-tuning could be demonstrated more clearly. In this study, I do not see clear improvement, and the scores are minor (but the realism cannot be evaluated by metrics such as FID in my opinion)
Formatting concerns
I don't see it
2 comments
Rebuttal
Thank you for recognizing our work and for providing valuable suggestions to improve the paper. We will carefully address your concerns as much as possible and further improve the manuscript accordingly.
For weakness 1:
Thank you for pointing out the issue with our visualization quality. Due to the page limitation during the submission stage, we had to reduce the figure sizes to reserve sufficient space for the main text. However, in the subsequent camera-ready version, we will present the visual results of our method with larger and clearer figures to better demonstrate the effectiveness of our approach.
For weakness 2 and question 1:
The primary goal of the reinforcement learning stage is to enhance the controllability of the template tumor over the generated tumor. Specifically, we aim for the generated tumors to better follow the provided tumor exemplars in terms of shape, texture, and high-level semantics (segmentation), thereby enabling the generation of rarer samples compared with pure text-based control and ultimately improving the generalization ability of downstream models.
In Figure 5, we demonstrate the improvement brought by RL in terms of tumor shape control, since shape changes are more visually intuitive than texture variations. In contrast, the texture differences between CT images are often subtle and difficult to perceive visually. Nevertheless, as shown in the reward curves in Figure 4, RL also substantially improves the controllability of the template tumor in terms of texture and high-level semantic information.
In the revised version, as you suggested, we will include high-resolution visual comparisons focusing on texture control to more clearly demonstrate the improvement brought by RL in enhancing texture controllability.
For weakness 3 and question 4:
The major computational cost of our training mainly comes from the supervised learning (SL) stage, which requires approximately 3,040 GPU hours. This is because the internal 4-cancer dataset used for training is a relatively large multi-type tumor dataset, and Flow Matching itself requires substantial training time for the model to learn the correct tumor distribution manifold. The computational cost is not caused by introducing complex architectures or additional mechanisms.
In contrast, the RL stage requires much less computation, with only 1,184 GPU hours, while still achieving considerable performance improvements. This demonstrates that introducing GRPO is a cost-effective design choice. The current design of MedGRPO is intentionally based on a minimal and practical framework, which provides good extensibility. For example, future researchers can flexibly incorporate domain-specific reward functions to address specialized tasks based on this framework, or replace the current CNN-based backbone with more advanced and popular architectures such as DiT. We will include the above discussions regarding computational cost, scalability, and future extensions in the conclusion section of the revised manuscript.
In addition, we evaluated the inference time of our model on a single standard CT scan using an H20 GPU:
| Components | Infer time | Ratio |
|---|---|---|
| VAE encoder | 4.48s | 65.7% |
| Diffusion sampling (20-step) | 1.84s | 27.0% |
| VAE decoder | 0.39s | 5.7% |
| Adapter | 0.04s | 0.6% |
| Full | 6.82s |
As can be seen, the major computational cost during inference comes from the VAE encoder, which performs CT compression and accounts for 65.7% of the total inference time. This is a necessary trade-off to preserve as much information from the original CT volume as possible. In contrast, the multi-step sampling process introduces relatively limited additional inference overhead. In principle, existing flow distillation methods can be applied to reduce the number of sampling steps and further decrease the inference time. Overall, an inference time of 6.82 seconds for a complete CT volume is acceptable in practice.
For weakness 4 and question 3:
Thank you for pointing out this issue. We acknowledge that evaluating on more visually prominent tumor types would strengthen the paper. However, since MedGRPO was trained specifically on these four cancer types, directly applying it to other tumor types without retraining would not yield meaningful results. Extending MedGRPO to these datasets is an important direction for future work.
To strengthen the quality assessment within our current evaluation scope, we took two complementary approaches. First, in the revised version, we will present high-resolution ROI crops of representative cases with more distinctive textures and larger tumor sizes, enabling readers to directly inspect the generation quality.
Second, we have also added an expert reader study to further evaluate the realism of the generated tumors. Specifically, we selected 200 cases, including 50 cases from each organ category (25 real tumors and 25 synthetic tumors). Two radiologists (R1: junior radiologist, R2: senior radiologist) were asked to examine consecutive slice sequences and classify each case as real or synthetic, without being informed of the exact proportion of real and synthetic cases. The following table summarizes the evaluation results from the two readers (positive: real tumor; negative: synthetic tumor). We report Sensitivity, Specificity, Accuracy, and Cohen’s Kappa. A lower Specificity score indicates that more synthetic tumors are incorrectly classified as real tumors, which directly reflects higher clinical plausibility and realism of the generated tumors. Cohen’s Kappa is used to measure the agreement between the two readers. The obtained value of 0.1748 (Slight Agreement) suggests that there are no systematic and obvious artifacts in the synthetic images that allow radiologists to consistently identify reliable visual cues. Instead, the readers mainly relied on their own subjective clinical experience when making their judgments.
| Reader | Sensitivity | Specificity | Accuracy | Cohen’s Kappa (Inter-reader Agreement) |
|---|---|---|---|---|
| R1 | 87.0% | 24.0% | 55.5% | 0.1748 |
| R2 | 88.0% | 62.0% | 75.0% | 0.1748 |
For question 2:
As suggested by you, we have added the evaluation results of MedGRPO (no-RL) to both Table 1 and Table 2, and conducted repeated experiments to ensure the reliability of the results. The updated experimental results are shown below:
Downstream experiment:
| Method | Kidney DSC ↑ | Kidney NSD ↑ | Liver DSC ↑ | Liver NSD ↑ | Pancreas DSC ↑ | Pancreas NSD ↑ |
|---|---|---|---|---|---|---|
| MedGRPO (no-RL) | 70.35±0.37 | 71.62±0.29 | 64.21±0.29 | 62.76±0.23 | 34.43±1.21 | 31.62±1.28 |
| MedGRPO | 71.20±0.27 | 72.43±0.41 | 64.23±0.25 | 62.73±0.31 | 36.66±0.80 | 33.85±0.80 |
FID evaluation experiment:
4-cancer dataset:
| method/organ | Breast | Kidney | Liver | Pancreas |
|---|---|---|---|---|
| MedGRPO (no-RL) | 64.67±1.71 | 59.24±0.67 | 30.71±0.37 | 27.71±0.23 |
| MedGRPO | 57.67±1.04 | 50.66±0.31 | 25.21±0.29 | 23.55±0.51 |
Atlas dataset:
| method/organ | Kidney | Liver | Pancreas |
|---|---|---|---|
| MedGRPO (no-RL) | 90.51±0.45 | 4.95±0.05 | 1.60±0.03 |
| MedGRPO | 83.35±0.47 | 3.27±0.03 | 2.30±0.06 |
The above experimental results demonstrate that the GRPO-based reinforcement learning post-training stage further improves the realism of the generated samples. By enhancing the model’s ability to generate rare tumor cases, the proposed approach ultimately improves the generalization capability of downstream segmentation models.
Thank you for increasing your rating. Your decision is a great encouragement to us. We also sincerely appreciate your valuable suggestions, which have contributed to improving the quality of our manuscript.
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper proposes MedGRPO, a framework for generating tumors in 3D CT scans using a real tumor exemplar as a reference. The main motivation is that simple controls such as text, masks, or bounding boxes do not fully describe the shape and texture of real tumors. The method first trains a latent flow-matching model on paired tumor CT data, and then uses an RL stage based on Flow-GRPO for unpaired tumor-free CTs and tumor exemplars. The RL stage uses texture, shape, and segmentation rewards, and it fine-tunes a lightweight adapter instead of the full U-Net.
Strengths and weaknesses
-
The paper studies an important problem. In medical imaging, rare tumor cases are often missing or under-represented, but these cases are important for training reliable models. The idea of using a real tumor exemplar as the condition is natural and useful. A tumor patch can carry richer information than a text label, mask, or bounding box, especially for texture and shape. This makes the proposed direction more interesting than standard mask- or text-conditioned synthesis.
-
The method is also technically interesting. The two-stage training design is reasonable: supervised flow matching first learns a basic tumor generation model, and the RL stage then tries to make the generated tumor better follow the exemplar under unpaired data. The reward design is intuitive, with separate rewards for texture, shape, and semantic tumor type. I also like the choice of training only a lightweight adapter during RL, since full U-Net fine-tuning could easily become unstable in this 3D setting.
-
- However, I have some important concerns. The biggest one is the downstream evaluation. The paper says that synthetic samples from different methods are used for augmentation, but Table 2 only shows real-data nnUNet versus MedGRPO-augmented nnUNet. This does not show whether MedGRPO is better than other synthesis methods for downstream segmentation. It only shows that adding MedGRPO synthetic data helps compared with no synthetic data. For the main practical claim, I think this comparison is necessary.
-
- Also, the main tables report single numbers, but I do not see error bars, confidence intervals, repeated runs, or significance tests. This matters because both synthetic data generation and nnUNet training can vary across seeds and data sampling. The checklist says statistical significance is addressed, but the reported results do not seem to include the needed information.
-
- the realism and controllability evidence is still somewhat indirect. FID on tumor ROIs is useful, but it is a rough proxy for medical realism. The ablations also mainly report the same reward values that are optimized during training, so they do not fully rule out reward hacking. A radiologist study, independent medical-domain metrics, or a nearest-neighbor analysis would make the results much more convincing. This is especially important because the segmentation reward uses a pretrained segmentation model, and the paper should make clear how this model was trained and whether it could bias the RL stage.
- There are also some presentation issues. Fig 1 gives the overall pipeline, but the relation between panels (a), (b), and (c) is not very clear. In particular, the inference panel may be easier to understand if it comes after the supervised learning and RL training panels. Also, in the current figure, flow matching, U-Net, and adapter look like separate independent components, while the text suggests a more connected training and fine-tuning process. I think the main figure should be redrawn to better show what is trained in each stage, what is frozen, what is reused, and how the inference pipeline uses the learned components.
- lastly, reproducibility and scope are still limited. The main training data are private, the full training cost is over 4k GPU hours, and the code is only promised after camera-ready. I understand that medical data cannot always be released, but the paper should give a clearer path for others to verify the results. The limitations section is also too short. It mainly says the method was only tested on CT and four organs, but it should also discuss privacy leakage, memorization of exemplar tumors, demographic bias, clinical validation, failure cases, and the compute cost.
Questions
-
Can the authors add downstream nnUNet augmentation results for the main baseline synthesis methods, such as LeFusion, LesionDiffusion, and DiffTumor, under the same AbdomenAtlas OOD protocol? This is the most important missing experiment for me. If MedGRPO clearly outperforms these methods for downstream segmentation, my confidence in the paper would increase.
-
Can the authors report repeated runs, standard deviations, confidence intervals, or statistical tests for Table 1 and Table 2? Please also clarify the number of seeds, train/test split choices, and synthetic sample sampling procedure.
-
How was the pretrained segmentation network used in the segmentation reward trained? Does its training data overlap with the internal dataset, the downstream nnUNet training data, or the external test data? How do the authors check for reward hacking or circularity?
-
How exactly is FID computed for 3D tumor ROIs? Is it based on 2D slices or 3D features? What feature backbone is used, and how are slices or volumes selected and preprocessed? A medical-domain feature encoder or an expert reader study would make the realism claim stronger.
-
Can the authors improve Figure 1 and clarify the pipeline order? I suggest showing supervised learning first, RL second, and inference last. The figure should also show which parts are frozen, which parts are trained, where the adapter is injected, and how the flow-matching/U-Net components relate to each other.
Limitations
The limitations discussion is not enough. The current limitation section mainly says that the method was tested only on CT images and four solid organs. That is true, but the paper should also discuss several other issues: dependence on a private clinical dataset, limited reproducibility, high compute cost, possible memorization or privacy leakage from tumor exemplars, demographic bias, lack of radiologist validation, possible reward hacking, and failure cases under domain shift. The authors should also explain what safeguards are needed before synthetic tumors from this model are used in real clinical model development.
Final justification
-
Resolved: The main downstream evaluation concern is largely resolved. The authors added comparisons with major synthesis baselines under the same OOD segmentation protocol, five-seed mean and standard deviation results, and a no-RL ablation. Moreover, the rebuttal better explains why trajectory-level RL is used for unpaired 3D flow matching. It also clarifies the segmentation reward model and volumetric FID evaluation, and adds radiologist and background-preservation analyses.
-
Remaining: The benefit of RL is not consistent across all organs and metrics. The liver segmentation improvement is negligible, and the no-RL model achieves a better external pancreas FID. Therefore, claims such as “consistently” or “significantly” outperforming should be softened unless formal statistical tests are provided. Also, the radiologist-study results should be interpreted more carefully. The novelty claim should also be narrowed because prior RL-based medical image synthesis has been reported. Reproducibility remains limited by the private training data, high computational cost, and the planned future release of code and checkpoints.
The added downstream comparisons and repeated experiments resolve my main reason for the initial rejection, and I give these improvements substantial weight. The remaining issues mainly concern claim calibration, novelty positioning, and reproducibility rather than a fundamental technical flaw. I therefore raise my score from 3 to 4.
Formatting concerns
There are also some checklist inconsistencies. The checklist marks statistical significance as addressed, but the main tables do not report error bars or significance tests. It also marks open access to data and code as “Yes,” while the code is only promised after camera-ready and the main clinical dataset is private. The theory/proofs item is also marked “Yes,” although the paper does not appear to contain formal theoretical results.
3 comments
Rebuttal
Thank you for recognizing our work and for your valuable suggestions. We will do our best to address each of your questions and provide additional experiments to resolve your concerns:
For weakness 1 and question 1:
As suggested by you, we have supplemented the downstream nnUNet data augmentation results of other baseline synthesis methods under the same out-of-domain AbdomenAtlas evaluation protocol. Specifically, we repeated the experiments with five different random seeds and report the mean and standard deviation. The results are shown below:
| Method | Kidney DSC ↑ | Kidney NSD ↑ | Liver DSC ↑ | Liver NSD ↑ | Pancreas DSC ↑ | Pancreas NSD ↑ |
|---|---|---|---|---|---|---|
| Baseline (nnUNet) | 64.51±0.49 | 63.95±0.74 | 60.08±0.45 | 57.53±0.61 | 31.54±0.28 | 27.61±0.30 |
| SynTumor | 64.39±0.55 | 64.32±0.57 | 63.08±0.42 | 63.17±0.50 | 33.20±1.27 | 30.31±1.19 |
| LeFusion | 65.59±0.46 | 65.71±0.53 | 59.83±0.31 | 58.45±0.32 | 31.75±1.15 | 27.43±0.91 |
| LesionDiffusion | 67.99±0.23 | 68.41±0.25 | 62.80±0.52 | 62.13±0.47 | 34.04±1.06 | 31.02±1.11 |
| DiffTumor | 69.51±0.20 | 70.31±0.26 | 63.40±0.20 | 62.92±0.37 | 34.85±0.81 | 32.26±0.89 |
| FreeTumor | 69.99±0.23 | 70.58±0.26 | 61.55±0.34 | 60.79±0.51 | 34.10±0.60 | 31.48±0.78 |
| MAISI | — | — | 60.36±0.34 | 59.12±0.19 | 31.65±0.96 | 28.22±0.81 |
| MedGRPO (no-RL) | 70.35±0.37 | 71.62±0.29 | 64.21±0.29 | 62.76±0.23 | 34.43±1.21 | 31.62±1.28 |
| MedGRPO (Ours) | 71.20±0.27 | 72.43±0.41 | 64.23±0.25 | 62.73±0.31 | 36.66±0.80 | 33.85±0.80 |
Our experimental results demonstrate that the proposed MedGRPO outperforms existing baseline methods on the downstream segmentation task under cross-dataset evaluation, validating the effectiveness of the overall framework. Furthermore, the comparison with MedGRPO (no-RL) shows that the GRPO-based reinforcement learning post-training stage effectively improves model performance. By enhancing the capability of the model to generate rare and diverse tumor samples, the proposed RL strategy ultimately improves the generalization ability of downstream segmentation models.
For weakness 2 and question 2:
As suggested by you, we conducted multiple repeated experiments for the FID evaluation and report the mean and standard deviation in the table below. Specifically, each method sampled the same number of fake samples (3,000 samples for each organ) using five different random seeds. The FID scores were then calculated based on the real samples from the test split of the corresponding dataset.
4-cancer dataset:
| method/organ | Breast | Kidney | Liver | Pancreas |
|---|---|---|---|---|
| SynTumor | - | 70.04±0.34 | 36.81±0.27 | 34.87±0.21 |
| LeFusion | 196.08±2.80 | 79.78±0.50 | 68.75±0.67 | 39.98±0.40 |
| LesionDiffusion | 97.38±0.98 | 79.93±0.13 | 36.17±0.34 | 42.06±0.26 |
| DiffTumor | - | 67.50±0.40 | 36.94±0.53 | 39.72±0.21 |
| FreeTumor | - | 141.71±0.31 | 115.68±0.17 | 109.29±0.06 |
| MAISI | - | - | 44.35±0.32 | 90.42±0.26 |
| MedGRPO (no-RL) | 64.67±1.71 | 59.24±0.67 | 30.71±0.37 | 27.71±0.23 |
| MedGRPO | 57.67±1.04 | 50.66±0.31 | 25.21±0.29 | 23.55±0.51 |
Atlas dataset:
| method/organ | Kidney | Liver | Pancreas |
|---|---|---|---|
| SynTumor | 94.23±0.64 | 7.95±0.10 | 13.92±0.10 |
| LeFusion | 104.64±0.15 | 27.55±0.38 | 10.55±0.13 |
| LesionDiffusion | 98.83±0.17 | 10.84±0.15 | 13.65±0.30 |
| DiffTumor | 70.16±0.59 | 9.68±0.35 | 10.17±0.14 |
| FreeTumor | 195.77±0.27 | 82.82±0.08 | 75.73±0.06 |
| MAISI | - | 20.97±0.14 | 52.50±0.22 |
| MedGRPO (no-RL) | 90.51±0.45 | 4.95±0.05 | 1.60±0.03 |
| MedGRPO | 83.35±0.47 | 3.27±0.03 | 2.30±0.06 |
The experimental results further validate the conclusions in Table 1. Our method consistently outperforms all baseline methods and achieves a clear improvement over the no-RL variant. These results demonstrate that our GRPO-based reinforcement learning strategy effectively improves the realism of the generated samples.
We will also incorporate these results into Table 1 in the revised manuscript to provide a more comprehensive evaluation.
For weakness 3 and question 3:
The segmentation network was trained on our internal 4-cancer dataset and does not involve any data from the external AbdomenAtlas test set. We acknowledge the data overlap with the generative model's training set. However, we address the reward hacking concern from three angles:
-
The segmentation reward is a well-defined task, not a learned scalar score. Unlike RLHF reward models trained on subjective preferences, our segmentation network performs a standard clinical task (tumor type segmentation) and the reward is computed as a Dice score against the binarized exemplar — a coarse, bounded signal. This is inherently harder to exploit than a learned scalar reward model.
-
Multi-objective reward prevents single-metric exploitation. Our RL stage jointly optimizes three orthogonal rewards (texture, shape, segmentation). As shown in Table 3, these rewards are genuinely competing: optimizing any single reward alone causes others to drop below the no-RL baseline, making it structurally difficult to hack all three simultaneously.
-
We believe that the cross-dataset downstream evaluation provides supportive evidence against circularity. Specifically, MedGRPO-augmented nnUNet also shows consistent improvements on the external AbdomenAtlas 2.0 dataset (Table 2, also see our Q1 response), which was not involved in any training stage. This cross-dataset generalization provides the evidence that the generated tumors capture genuine tumor characteristics rather than reward-specific artifacts.
We will incorporate this discussion into the revised manuscript.
For weakness 3 (continued) and question 4:
Our FID metric is computed using volumetric data. Specifically, we extract features only from the region inside the ROI bounding box rather than from the entire CT volume. The feature extractor is based on TotalSegmentator [1], a publicly available pretrained model for whole-body anatomical structure segmentation. We use the features from the final layer immediately before the segmentation head to compute FID.
As suggested by you, we further conducted a radiologist evaluation to better demonstrate the realism of the generated tumors. Specifically, we selected 200 cases, including 50 cases from each organ category (25 real tumors and 25 synthetic tumors). Two radiologists (R1: junior radiologist, R2: senior radiologist) were asked to examine consecutive slice sequences and classify each case as real or synthetic, without being informed of the exact proportion of real and synthetic cases. The following table summarizes the evaluation results from the two readers (positive: real tumor; negative: synthetic tumor). We report Sensitivity, Specificity, Accuracy, and Cohen’s Kappa.
| Reader | Sensitivity | Specificity | Accuracy | Cohen’s Kappa (Inter-reader Agreement) |
|---|---|---|---|---|
| R1 | 87.0% | 24.0% | 55.5% | 0.1748 |
| R2 | 88.0% | 62.0% | 75.0% | 0.1748 |
A lower Specificity score indicates that more synthetic tumors are incorrectly classified as real tumors, which directly reflects that the generated tumors possess higher clinical plausibility and realism. Cohen’s Kappa is used to evaluate the agreement between the two readers. The obtained value of 0.1748 (Slight Agreement) suggests that there are no obvious systematic artifacts in the synthetic images that allow radiologists to consistently identify them. Instead, the readers mainly relied on their own subjective clinical experience when making the judgments.
[1] Wasserthal J, Breit H C, Meyer M T, et al. TotalSegmentator: robust segmentation of 104 anatomic structures in CT images[J]. Radiology: Artificial Intelligence, 2023, 5(5): e230024.
For weakness 4 and question 5:
Thank you for your suggestion. We will revise Figure 1 accordingly. Specifically, we will move the inference stage below the training stages, and further clarify the injection locations of the adapters as well as refine the connections between different modules.
For weakness 5:
We acknowledge the concerns regarding reproducibility. While the clinical dataset cannot be released due to institutional policies, we will provide the full training code, pretrained model checkpoints, and detailed reproduction instructions upon acceptance. We will also clarify the exact data preprocessing pipeline and hyperparameter settings to facilitate replication on other datasets.
Besides the above issues, due to the page limit during the submission stage, we shortened the discussion section in the conclusion. In the subsequent revision stage, as you suggested, we will expand the conclusion section to include further discussions and explanations regarding privacy concerns, computational costs, failure cases, and other related limitations.
Dear Reviewer,
Thank you again for your time and effort in reviewing our paper. We completely understand that you may have a busy schedule and appreciate your time. Since the rebuttal period is approaching its end, we would like to kindly remind you that our responses to your comments have been posted. We would greatly appreciate it if you could take some time to review our responses when convenient. Your feedback and further discussion would be very valuable for us to improve our work.
Thank you very much for your consideration.
Thank you very much for your careful evaluation and for increasing your rating after considering our rebuttal. Your recognition is a great encouragement to us and further motivates us to continue improving this work.
We sincerely appreciate your constructive comments and insightful suggestions throughout the review process. They have helped us identify important aspects that could be strengthened, and have significantly contributed to improving the quality, completeness, and rigor of our manuscript.
We will carefully incorporate these valuable suggestions into the revised version and make further efforts to enhance the presentation and technical quality of the paper.
Thank you again for your time, effort, and valuable feedback.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Thank you to the AC for summarizing the reviewers' comments and suggestions for improvement. We have provided detailed responses to these concerns in our replies to the reviewers and have made corresponding improvements to our manuscript.
In addition, we noticed that the issues (1) and (5) summarized in your meta-review were not explicitly raised in the reviewers' comments. Therefore, we would like to provide separate responses to these two points below:
For issue (1):
As discussed in the paper, we adopt reinforcement learning as our post-training strategy to optimize the model using unpaired data. Note that the similarity of shape, texture, and high-level semantics (segmentation) all needs to be evaluated between the generated results and the reference exemplars. Since Flow Matching generates samples through multi-step ODE sampling, directly computing a differentiable loss between the generated sample and the reference exemplar and backpropagating through the sampling process would require storing the intermediate activations of all ODE steps. Such memory consumption is often prohibitive, especially for 3D CT data.
Another seemingly feasible differentiable optimization strategy was explored in our early experiments. Specifically, we used the one-step estimated x^1 as a surrogate generated sample within a single sampling step, and optimized a differentiable loss between x^1 and the reference exemplar, thereby avoiding the need to backpropagate through the complete ODE trajectory. However, our empirical results showed that this strong constraint substantially reduced the diversity of generated samples and disrupted the distribution manifold learned during the pretraining stage.
In contrast, Flow-GRPO performs trajectory-level optimization by using rewards as soft optimization objectives, encouraging the model to explore the learned manifold while avoiding the issues caused by overly strong constraints. Meanwhile, it does not require storing intermediate activations along the entire ODE trajectory. Therefore, for our goal of optimizing the model with unpaired data, Flow-GRPO is a more suitable choice.
We will incorporate the above discussion into the Discussion section in the revised version to provide a clearer explanation of our motivation and design choice to readers.
For issue (5):
We would like to first clarify that MedGRPO is designed as an inpainting-style framework. The tumor region is synthesized in the latent space and blended with the original CT via mask-based latent mixing (Eq. 8), where only the latent within the target bounding box are replaced while the surrounding latent features remain unchanged. This design inherently preserves the background anatomy by construction.
To quantitatively evaluate whether our method preserves the surrounding anatomy outside the synthesized tumor region, we randomly sampled 1,000 tumor-free CT volumes and evaluated how well the surrounding anatomy is preserved after tumor synthesis. Specifically, we computed PSNR and SSIM between the original tumor-free images and the generated images, restricted to the background region (excluding the synthesized tumor mask). The VAE reconstruction serves as an upper-bound reference since it introduces no generative modification:
MedGRPO achieves 30.39 dB PSNR and 0.93 SSIM in the background region, confirming that the surrounding anatomy remains highly consistent with the original scans after tumor synthesis. The slight drop compared to VAE reconstruction is expected, as the latent blending at tumor boundaries can have limited spillover effects.