potentialpaper

HALMES: Knowing When to Intervene in LVLM Hallucination Mitigation

Ruining Hu, Jiaqi Lu, Xiao Liu, Ying Shen, Yu Wang, Lin Zhang

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

Abstract. Large Vision-Language Models (LVLMs) have demonstrated strong capabilities in multimodal tasks. Nevertheless, their outputs remain prone to object hallucinations that are inconsistent with visual content. Contrastive decoding, as a training-free inference-time mitigation approach, typically intervenes in the output distribution at every decoding step. However, such indiscriminate full-stage intervention may disrupt originally correct generations and even induce new hallucinations. To address this issue, we first analyze the relationship between internal attention features and hallucinated token segments in LVLMs, revealing that hallucination-related abnormalities already emerge progressively in preceding token segments. Based on this observation, we propose HALMES, a lightweight plug-and-play module that identifies hallucination precursor segments from attention features during generation and selectively triggers contrastive decoding. HALMES can be integrated with various full-stage contrastive decoding methods, transforming indiscriminate intervention into on-demand targeted correction. Extensive experiments across different LVLM architectures and multiple benchmarks show that HALMES further improves the hallucination mitigation performance of existing contrastive decoding methods while reducing the negative impact of full-stage intervention on normal outputs, validating the importance of modeling and selectively intervening on hallucination-prone segments.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
27 Apr 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:45 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

This paper proposes HALMES, a plug-and-play module designed to mitigate object hallucinations in LVLMs. Instead of applying CD indiscriminately at every generation step, HALMES utilizes internal attention features to detect hallucination-prone token segments in real-time. It selectively triggers CD only when a high hallucination risk is predicted, transforming full-stage intervention into a targeted, on-demand correction mechanism.

The main strengths

• The method successfully addresses the collateral damage caused by constant CD intervention by proposing a targeted, segment-level activation strategy.

• HALMES is lightweight and can be integrated with various existing CD methods without altering their core formulations.

• The authors provided extensive additional analyses, including leave-one-feature-out ablations, random/periodic activation controls, and cross-architecture validations on Qwen3.5-9B, strengthening the empirical evidence.

(c) The main weaknesses

• While effective for in-domain object hallucinations, the performance gains on broader multimodal tasks remain preliminary and sometimes yield mixed results or marginal improvements.

• The method relies on fixed, manually calibrated thresholds that require model-specific tuning using a validation set, potentially limiting seamless cross-architecture applicability.

The authors provided a thorough and convincing rebuttal that systematically addressed the concerns raised in the initial meta-review. • They clarified that both decoding branches are computed throughout generation, and HALMES merely gates the logit recombination; thus, the latency difference between triggered and non-triggered samples is negligible, resolving the true computational cost concern.

• By comparing HALMES against frequency-matched random and periodic activation baselines, the authors proved that the performance gains strictly stem from the attention-based risk signal, outperforming the baselines in 90/90 pairwise comparisons.

• They added the requested component-wise ablations, showing all five attention features contribute meaningfully. Furthermore, they demonstrated that the fixed thresholds selected via validation transfer reliably across data distributions within the same LVLM. Following the rebuttal, Reviewer ZKn1 raised their rating to an Accept (5), Reviewer NbG5 expressed satisfaction with the clarifications and stated an intention to raise their score (3), and Reviewer ZNDY confidently maintained a Borderline Accept (4).

The decision to accept is based on the paper's technically sound approach to a recognized problem in contrastive decoding and the authors' exceptional rebuttal. The initial reservations regarding latency masking, the causal value of the risk signal, and hyperparameter sensitivity were resolved with empirical evidence. Although the method's benefits are most pronounced for object hallucinations and require model-specific calibration, the core contribution, an on-demand, attention-guided intervention mechanism, is well-supported. The consensus among reviewers leans positive, confirming the technical solidity of the framework.

Final justification

The authors addressed critical concerns raised during the review process. The extensive additional experiments provided during the rebuttal, including feature ablations, control baselines for CD frequency, and evaluation on new architectures like Qwen3.5-9B, firmly establish the validity of the HALMES framework. Reviewers acknowledged that the paper provides a practical and effective solution to reduce the negative side effects of full-stage contrastive decoding. Because the reasons to accept—technical coherence, thorough empirical validation, and a strong rebuttal—outweigh the remaining limitations regarding out-of-domain generalization, the paper merits acceptance.

Area Chair dgVC · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

This paper proposes HALMES, a plug-and-play module designed to mitigate object hallucinations in LVLMs. Instead of applying CD indiscriminately at every generation step, HALMES utilizes internal attention features to detect hallucination-prone token segments in real-time. It selectively triggers CD only when a high hallucination risk is predicted, transforming full-stage intervention into a targeted, on-demand correction mechanism.

The main strengths

• The method successfully addresses the collateral damage caused by constant CD intervention by proposing a targeted, segment-level activation strategy.

• HALMES is lightweight and can be integrated with various existing CD methods without altering their core formulations.

• The authors provided extensive additional analyses, including leave-one-feature-out ablations, random/periodic activation controls, and cross-architecture validations on Qwen3.5-9B, strengthening the empirical evidence.

(c) The main weaknesses

• While effective for in-domain object hallucinations, the performance gains on broader multimodal tasks remain preliminary and sometimes yield mixed results or marginal improvements.

• The method relies on fixed, manually calibrated thresholds that require model-specific tuning using a validation set, potentially limiting seamless cross-architecture applicability.

The authors provided a thorough and convincing rebuttal that systematically addressed the concerns raised in the initial meta-review. • They clarified that both decoding branches are computed throughout generation, and HALMES merely gates the logit recombination; thus, the latency difference between triggered and non-triggered samples is negligible, resolving the true computational cost concern.

• By comparing HALMES against frequency-matched random and periodic activation baselines, the authors proved that the performance gains strictly stem from the attention-based risk signal, outperforming the baselines in 90/90 pairwise comparisons.

• They added the requested component-wise ablations, showing all five attention features contribute meaningfully. Furthermore, they demonstrated that the fixed thresholds selected via validation transfer reliably across data distributions within the same LVLM. Following the rebuttal, Reviewer ZKn1 raised their rating to an Accept (5), Reviewer NbG5 expressed satisfaction with the clarifications and stated an intention to raise their score (3), and Reviewer ZNDY confidently maintained a Borderline Accept (4).

The decision to accept is based on the paper's technically sound approach to a recognized problem in contrastive decoding and the authors' exceptional rebuttal. The initial reservations regarding latency masking, the causal value of the risk signal, and hyperparameter sensitivity were resolved with empirical evidence. Although the method's benefits are most pronounced for object hallucinations and require model-specific calibration, the core contribution, an on-demand, attention-guided intervention mechanism, is well-supported. The consensus among reviewers leans positive, confirming the technical solidity of the framework.

Final justification

The authors addressed critical concerns raised during the review process. The extensive additional experiments provided during the rebuttal, including feature ablations, control baselines for CD frequency, and evaluation on new architectures like Qwen3.5-9B, firmly establish the validity of the HALMES framework. Reviewers acknowledged that the paper provides a practical and effective solution to reduce the negative side effects of full-stage contrastive decoding. Because the reasons to accept—technical coherence, thorough empirical validation, and a strong rebuttal—outweigh the remaining limitations regarding out-of-domain generalization, the paper merits acceptance.

1 comment
Authors · CommentOpenReview ↗

Response to the AC Summary

Thank you for the careful synthesis. We are encouraged that the reviewers recognize HALMES’s motivation and significance, particularly its shift from conventional full-stage contrastive decoding to a hallucination-risk-guided targeted intervention paradigm. We also appreciate their recognition of our evaluation across five CD methods and our rescue/collateral-risk analyses.

We address the five concerns below:

  1. Activation frequency and actual inference cost.
    We clarified that the average latency does not mask a substantially higher computation cost when HALMES is activated. In the official implementations of all evaluated full-stage CD methods, the original and contrastive branches are computed throughout generation. HALMES only gates whether the available logits are contrastively recombined at each step. Averaged across five CD methods, the sample-level trigger rates are 66.0%/65.6%, and the active-step ratios are 71.31%/73.17% on Qwen3VL-8B/InternVL3.5-8B. The triggered and non-triggered latencies are 11.3205/11.2951 s and 12.0134/11.8713 s, respectively, differing by only 0.0254 s and 0.1421 s. These measurements confirm that the observed latency difference arises from gating the logit-recombination operation, rather than from conditionally computing the contrastive branch.

  2. Technical scope and value of risk-guided activation.

  • Contrastive branch. HALMES strictly inherits each baseline’s distorted-input construction, contrastive branch, hyperparameters, and logit-adjustment rule. It introduces neither a new distorted input nor an additional contrastive branch.

  • Risk-guided activation. We evaluated six random and periodic intervention policies across multiple reduced activation rates, including settings close to HALMES’s active-step ratio. Our analysis (Reviewer ZNDY, Q1) confirms that these reduced-frequency policies do not consistently improve full-stage CD and all worsen CHAIR$_i$. In contrast, HALMES achieves the best average performance on all three metrics and consistently outperforms these baselines across all five CD methods. This indicates that the gains arise from the attention-based risk signal rather than merely applying CD less frequently.

  1. Contribution of the five attention-derived features.
    We further conducted controlled leave-one-feature-out ablations (Reviewer ZNDY, Q2) for both hallucination detection and mitigation on Qwen3VL-8B and InternVL3.5-8B. Removing any feature decreases AUROC and increases FPR on both models, while every ablation degrades at least one hallucination-mitigation metric. VAR has the largest individual impact, and the remaining features provide complementary information. The full feature set achieves the strongest overall detection performance and the lowest average CHAIR$_i$ and CHAIR$_s$ across all five CD methods on both LVLMs.

  2. Threshold sensitivity and practical calibration.

  • Transferability across scenarios. In all reported experiments for a given LVLM, HALMES uses a single detector and the same fixed threshold configuration across all datasets, prompt styles, and five CD methods, without scenario-specific recalibration. The consistent gains in our main results therefore already provide evidence of transferability within the same LVLM. Our additional transfer experiment (Reviewer ZKn1, Q1) further shows that the setting selected on AMBER remains the best among the tested candidates on both hallucination metrics on a disjoint COCO subset, supporting transfer across data distributions.

  • Practical selection. HALMES does not require a validation set matched to each new OOD scenario. Thresholds are calibrated once on a small generic image batch using an "FPR budget and hysteresis gap" to balance hallucination reduction with coverage, then reused across datasets and prompts.

  1. Informativeness and non-object hallucinations.
  • Informativeness trade-off. Our response-behavior analysis (Reviewer ZNDY, Q4) shows that HALMES’s gains are not achieved by shortening or suppressing responses. Because some hallucinations resemble normal generation in attention patterns, false activations may suppress visually weak but correct details, occasionally lowering Coverage or Bingo. Threshold-sensitivity analysis (Table 4 of the paper) shows that, relative to the highest-Coverage setting, the default reduces Coverage by 2.45 pp while lowering hallucination by 14 pp, reflecting a controlled trade-off.

  • Non-object hallucinations. Although HALMES is trained using MSCOCO/CHAIR object localizations, it models hallucination-precursor patterns in attention dynamics rather than specific object identities. Our additional experiments (Reviewer NbG5, Q4) show improved total scores in all 10/10 backbone–CD combinations and improved commonsense reasoning in 9/10, with further gains in counting, position, OCR, and other non-object categories.

Reviewer ZNDYOpenReview ↗
Rating
4/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper introduces HALMES, an inference-time framework for mitigating hallucinations in LVLMs. Its central idea is to identify hallucination-prone token segments during generation from internal attention-derived signals, and to selectively activate contrastive decoding only when intervention is predicted to be necessary. HALMES incorporates features including the visual attention ratio, prompt attention, generated-text attention, text-to-visual attention ratio, and attention entropy, together with a sliding-window detector, online normalization, and a dual-threshold hysteresis mechanism. The reported results indicate that, across several settings, HALMES-guided decoding can retain or improve the hallucination-mitigation benefits of full-sequence contrastive decoding while reducing unnecessary intervention on low-risk generation segments.

Strengths and weaknesses

Strength

  1. The proposed method is technically well specified. It defines token-segment representations from five attention-derived signals, and explains how these features are processed during inference.
  2. The experimental design evaluates HALMES jointly with five existing contrastive decoding methods, rather than presenting results for only one selected baseline. This makes the proposed intervention mechanism more broadly tested within the contrastive-decoding setting.
  3. The appendix provides an inference-time deployment algorithm and documents implementation, training, benchmark, threshold-selection, transferability, and latency-analysis details, which improves methodological transparency.

Weakness

  1. The paper does not include a standard evaluation of general visual question answering or other non-hallucination capabilities under HALMES-guided decoding.
  2. The paper provides feature visualizations, VAR-range analyses, and threshold studies, but it does not present a systematic component-wise ablation that isolates the contribution of each attention feature.
  3. The experiments do not fully isolate the value of the proposed hallucination-risk signal from the benefit of merely applying contrastive decoding less frequently.
Questions
  1. HALMES uses activation and deactivation thresholds selected on validation data. How sensitive are the final results to the threshold-selection criterion, and how well do the selected thresholds transfer across different datasets or prompting styles for the same LVLM?
  2. What is the average fraction of decoding steps for which HALMES activates contrastive decoding on each benchmark?
  3. Does HALMES affect average response length, the rate of abstentions or refusals, or the frequency of incomplete answers? These quantities would help assess whether hallucination reductions are accompanied by changes in answer behavior.
  4. Can the authors provide a structured analysis of failure cases, including false activations on correct responses, missed hallucinations, and cases where intervention changes a previously correct answer into a less useful one?
Limitations
  1. The detector supervision is narrowly tied to object hallucinations, and does not directly establish effectiveness for other hallucinations.
  2. The paper does not provide a component-wise ablation of the five attention-derived features. It is therefore unclear how much each feature contributes individually, or whether a smaller subset of features would achieve comparable performance.
  3. The results support their usefulness for discrimination in the reported settings, but they do not establish that these attention patterns are causal mechanisms of hallucination.
Final justification

My current score accurately reflects the rating of the paper.

Formatting concerns

None

3 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We sincerely thank the reviewer for the careful and constructive assessment. We greatly appreciate your recognition of HALMES’s technically well-specified design and its comprehensive evaluation across five contrastive decoding methods.

To address the remaining concerns, we provide additional controlled experiments and analyses below.


Q1: Does HALMES’s hallucination-risk signal provide benefits beyond merely reducing the frequency of contrastive decoding?

A1: To isolate the value of risk-guided activation, we compare HALMES with six frequency-controlled baselines across all five CD methods on the COCO subset. Random activation independently applies CD with probabilities of 0.3, 0.5, and 0.7, while periodic activation applies CD for 3, 5, or 7 consecutive steps within each 10-step cycle. Since HALMES activates CD for approximately 70% of decoding steps, Random-0.7 and Periodic-7:3 provide frequency-matched comparisons.

R3-Table 1: Comparison with random and periodic CD activation. Results are averaged across the five CD methods.

Method / Activation Policy CHAIR$_i$ ↓ CHAIR$_s$ ↓ Coverage ↑
Base (Nucleus) 14.45 37.02 38.77
Full-stage CD 13.11 36.44 40.68
Random-0.3 13.90 36.90 40.86
Random-0.5 13.90 36.63 42.71
Random-0.7 14.60 36.85 40.80
Periodic-3:7 14.18 35.63 41.06
Periodic-5:5 14.28 36.86 41.60
Periodic-7:3 14.67 36.48 41.03
HALMES 12.29 32.40 44.81

HALMES achieves the best average performance on all three metrics. Compared with the frequency-matched Random-0.7 and Periodic-7:3 baselines, it improves CHAIR$_i$/CHAIR$_s$/Coverage by 2.31/4.45/4.01 pp and 2.38/4.08/3.78 pp, respectively.

R3-Table 2: HALMES improvement over the best random or periodic activation baseline for each CD method. Positive values denote absolute percentage-point improvements; the best baseline is selected separately for each metric.

CD Method Δ\DeltaCHAIR$_i$ ↑ Δ\DeltaCHAIR$_s$ ↑ Δ\DeltaCoverage ↑
VCD +1.14 +5.15 +2.46
M3ID +1.38 +0.97 +1.23
AVISC +0.82 +1.03 +0.07
SID +1.30 +1.87 +2.54
Self-Aug +1.06 +1.90 +2.99

HALMES outperforms the best random or periodic activation baseline on all three metrics for every CD method. Moreover, across all six baselines, five CD methods, and three metrics, HALMES performs better in all 90/90 pairwise comparisons. This confirms that the gains arise from risk-guided localization rather than merely reducing CD frequency.


Q2: How much does each attention-derived feature contribute, and can a smaller feature subset achieve comparable performance?

A2: We conduct leave-one-feature-out ablations on both hallucination detection and mitigation.

Hallucination detection. We remove each attention-derived feature individually while keeping the detector architecture and training settings unchanged.

R3-Table 3: Component-wise ablation of the five attention-derived features for hallucination detection. All metrics are reported as percentages.

Qwen3VL-8B

Setting AUROC ↑ Accuracy ↑ Recall ↑ PR-AUC ↑ FPR ↓
w/o VAR 78.94 73.11 81.78 76.53 35.56
w/o Prompt Attention 88.68 80.22 75.56 88.42 15.11
w/o Generated-Text Attention 88.80 82.22 84.89 89.54 20.44
w/o Text-Visual Ratio 87.87 82.22 82.67 88.81 18.22
w/o Outgoing Attention Entropy 87.91 82.44 80.89 88.89 16.00
Full 91.31 86.73 86.39 88.76 12.93

InternVL3.5-8B

Setting AUROC ↑ Accuracy ↑ Recall ↑ PR-AUC ↑ FPR ↓
w/o VAR 81.72 75.30 88.10 79.28 37.50
w/o Prompt Attention 88.14 81.70 85.71 88.63 22.32
w/o Generated-Text Attention 88.07 81.85 87.80 88.68 24.11
w/o Text-Visual Ratio 88.15 81.70 77.98 88.71 21.13
w/o Outgoing Attention Entropy 88.13 80.95 80.36 88.58 21.96
Full 90.52 83.63 87.20 90.03 19.94

All five features contribute consistently: removing any one decreases AUROC and increases FPR on both LVLMs. VAR is the most important, as its removal causes the largest AUROC drops and FPR increases. Although some ablations slightly improve Recall or PR-AUC, the full feature set provides the strongest overall detection performance.

Hallucination mitigation. We further combine each feature-ablated detector with all five CD methods. Due to space constraints, we report the average performance over the five CD methods.

R3-Table 4: Component-wise feature ablation for hallucination mitigation. Full-stage CD and all HALMES variants are averaged across five CD methods. All metrics are reported as percentages.

Setting Qwen3VL-8B CHAIR$_i$ ↓ Qwen3VL-8B CHAIR$_s$ ↓ Qwen3VL-8B Coverage ↑ InternVL3.5-8B CHAIR$_i$ ↓ InternVL3.5-8B CHAIR$_s$ ↓ InternVL3.5-8B Coverage ↑
Nucleus 12.50 28.00 56.00 12.31 36.00 68.00
Full-stage CD 11.71 29.40 54.16 11.87 38.20 67.92
w/o VAR 11.30 26.80 55.04 12.13 37.60 66.96
w/o Prompt Attention 11.38 27.20 55.76 11.57 36.40 66.96
w/o Generated-Text Attention 10.14 26.40 55.76 10.82 34.80 66.88
w/o Text-Visual Ratio 11.37 28.00 55.36 12.64 38.40 67.76
w/o Outgoing Attention Entropy 10.27 24.60 54.24 11.63 36.40 68.48
HALMES (Full) 9.11 24.40 55.68 9.98 30.20 66.48

The full feature set achieves the lowest average CHAIR$_i$ and CHAIR$_s$ among all feature ablations on both LVLMs. Removing any feature degrades at least one hallucination metric, while Coverage remains comparable on Qwen3VL-8B and exhibits a moderate trade-off on InternVL3.5-8B. These results further support the complementary contribution of the five features.


Q3: How sensitive are HALMES’s thresholds, and how well do they transfer across datasets and prompting styles?

A3: HALMES requires a small model-specific validation set for initial calibration. We select θhigh\theta_{\mathrm{high}} and θlow\theta_{\mathrm{low}} through an FPR budget α\alpha and a hysteresis gap. Our sensitivity analysis shows that a conservative FPR budget (α=0.05\alpha=0.05) with a moderate gap (0.100.10) provides the strongest hallucination mitigation.

For each LVLM, the same detector and fixed thresholds are used across all evaluated datasets, prompt styles, and five CD methods, without scenario-specific recalibration. Moreover, the validation-selected setting remains optimal on a disjoint COCO subset, supporting its transferability within the same LVLM.

Due to space limitations, please refer to response to Reviewer ZKn1 (Q1) for more detailed results. Thanks!


Q4: Does HALMES affect response length or increase abstentions, refusals, or incomplete answers?

A4: We evaluate free-form image descriptions on a COCO subset and find that HALMES does not materially alter answer behavior.

R3-Table 5: Response-behavior analysis on a COCO subset.

Metric HALMES+CD Full-stage CD Nucleus Δ\Delta vs. CD Δ\Delta vs. Nucleus
Average response length 420.31 414.16 434.32 +6.15 (+1.48%) −14.01 (−3.23%)
Abstention/refusal rate 0.00% 0.00% 0.00% +0.00 pp +0.00 pp
Incomplete-answer rate 0.00% 0.00% 0.00% +0.00 pp +0.00 pp

HALMES produces slightly longer responses than full-stage CD, while introducing no abstentions, refusals, or incomplete answers. Thus, its hallucination reduction is not achieved by shortening or suppressing model responses.


Q5: Does HALMES preserve general visual question answering and other non-hallucination capabilities?

A5: To assess whether hallucination reduction comes at the cost of general capabilities, we additionally evaluate HALMES on MME under complete-response prompting, covering visual question answering and commonsense reasoning.

Across two LVLMs and five CD methods, HALMES improves the overall MME score in all 10 model–method combinations, with average relative gains of 2.30% on Qwen3VL-8B and 1.70% on InternVL3.5-8B. Commonsense reasoning also improves in 9 of the 10 settings. These results suggest that HALMES does not trade general capabilities for hallucination reduction. Instead, it preserves overall VQA performance and often further improves reasoning ability.

Due to space limitations, please refer to response to Reviewer NbG5 (Q4) for detailed results. Thanks!


Q6: What fraction of decoding steps activates contrastive decoding?

A6: Averaged across the five CD methods, HALMES activates contrastive decoding for 71.31% of decoding steps on Qwen3VL-8B and 73.17% on InternVL3.5-8B. Across individual benchmarks, the active-step ratios remain within approximately 64%–81%, indicating moderate variation but broadly consistent activation behavior. The relatively high activation rate reflects this conservative calibration: HALMES prioritizes covering high-risk segments while limiting false activations. Detailed results are provided in our response to Reviewer NbG5 (Q3).


Q7: A structured analysis of HALMES failure cases

A7: We identify three main failure modes: false activations on visually weak but correct content, missed hallucinations with normal-like attention patterns, and harmful interventions that make an originally correct response less informative. These cases arise from overlapping attention patterns and reflect the trade-off between hallucination reduction and information preservation.


We sincerely appreciate your feedback and hope our responses have addressed your concerns.

Reviewer ZNDY · CommentOpenReview ↗

I have carefully reviewed your response. I believe that my current score accurately reflects the rating of the paper, and I have therefore decided to maintain my original score.

Authors · CommentOpenReview ↗

Thank you for carefully reviewing our response and for your continued consideration of our work. We sincerely appreciate the time and attention you devoted to the review process. Your comments have helped us identify areas for further improvement and will be valuable in strengthening the final version of the paper. We are grateful for your thoughtful engagement throughout the discussion.

Reviewer ZKn1OpenReview ↗
Rating
5/6
Confidence
4/5
Quality
3/4
Clarity
2/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper proposes HALMES, a lightweight and plug-and-play module designed to mitigate object hallucination in LVLMs. The key idea of HALMES is to precisely identify anomalous token segments during generation based on internal attention features of LVLMs, and to selectively trigger contrastive decoding only when necessary. In this way, HALMES transforms the traditional indiscriminate full-stage intervention paradigm into an on-demand and targeted correction mechanism. The authors conduct comprehensive experiments across multiple LVLM architectures and benchmark datasets, demonstrating the effectiveness of token-segment-level hallucination detection and targeted intervention.

Strengths and weaknesses

Strengths:

  • The most important strength of HALMES is that it changes the conventional Contrastive Decoding paradigm of indiscriminate full-stage intervention. By detecting potential anomalous token segments in real time as hallucination precursors, HALMES enables selective and on-demand activation of contrastive decoding.
  • The paper provides an in-depth analysis of the internal attention mechanisms of LVLMs and derives several attention-based features from them. These features are shown to be highly specific indicators of hallucination precursors and also exhibit good generality across different LVLM architectures.
  • HALMES can further improve hallucination mitigation performance in most settings. More importantly, it substantially reduces the harmful cases and negative impact introduced by full-stage intervention methods.

Weaknesses:

  • HALMES relies on predefined thresholds, namely θ_high and θ_low, to determine when to trigger or stop contrastive decoding. However, different LVLM architectures, input scenarios, and generation stages may exhibit different attention distributions and risk-score scales. Therefore, fixed thresholds may not capture the optimal decision boundary in all cases, which could limit the practical applicability of HALMES in real-world settings.
  • In Section 5.2 Q2, the authors show that HALMES may reduce the Visual Ground-Truth Coverage (Cov.) of some methods, potentially making the generated descriptions slightly more conservative. How should this trade-off be balanced?
  • The △relative results in Table 2 appear to be somewhat redundant, since the absolute percentage-point improvement column already provides sufficient information.
Questions
  • How should appropriate values of θ_high and θ_low be selected in real-world scenarios? Does this require sampling a small validation set?
  • Since the language model component of InternVL 3.5 is initialized from Qwen3 and GPT-OSS [1], the attention-based features of Qwen3-VL and InternVL 3.5 may be similar. Could the authors evaluate HALMES on more native multimodal models, such as Qwen3.5-9B?

Reference: [1] https://internvl.github.io/blog/2025-08-26-InternVL-3.5/

Limitations

yes

Final justification

My concerns focused on two aspects: (1) generalization across different data domains, particularly because the authors need additional datasets to determine certain hyperparameters. (2) generalization across different model architectures, since the language model components of InternVL 3.5 are initialized from Qwen3 and GPT-OSS. The authors conducted additional experiments addressing each of these concerns, and their response has resolved my two questions.

Formatting concerns

no

3 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We sincerely thank the reviewer for the positive and insightful feedback. We are particularly encouraged by your recognition of HALMES’s core contribution: transforming indiscriminate full-stage contrastive decoding into targeted, on-demand intervention through token-segment-level hallucination detection. We also greatly appreciate your positive assessment of our attention-based analysis and HALMES’s ability to reduce the harmful effects of unnecessary intervention.

Your comments regarding the architectural similarity between Qwen3-VL and InternVL3.5 is highly insightful and directly concerns the generality of HALMES. To further assess its applicability to more native multimodal architectures, we conducted additional experiments on Qwen3.5-9B. Below, we provide detailed responses to all comments:


Q1: How should θhigh\theta_{\mathrm{high}} and θlow\theta_{\mathrm{low}} be selected in practice, and how transferable are fixed thresholds?

A1: HALMES does require a small model-specific validation set for initial threshold calibration. In our experiments, for each LVLM, we use the same fixed thresholds across different datasets, prompt styles, and CD methods. The consistent results indicate that these thresholds exhibit reasonable transferability within the same LVLM. Specifically, we select an FPR budget α\alpha and a hysteresis gap between θhigh\theta_{\mathrm{high}} and θlow\theta_{\mathrm{low}}. R2-Table 1 shows that a conservative FPR budget with a moderate gap provides the strongest hallucination mitigation:

R2-Table 1: Sensitivity analysis and validation-based selection of θhigh\theta_{\mathrm{high}} and θlow\theta_{\mathrm{low}} on a disjoint AMBER subset.

Setting α\alpha Gap CHAIR ↓ Cover ↑ Cog ↓ Hal ↓
Conservative budget 0.05 0.10 7.25 49.36 3.78 31.00
Balanced budget 0.10 0.10 9.51 49.48 4.52 46.00
Relaxed budget 0.15 0.10 10.68 50.83 4.35 49.00
No hysteresis 0.05 0.00 8.53 48.77 3.42 41.00
Narrow gap 0.05 0.05 8.81 51.81 4.14 45.00
Wide gap 0.05 0.15 8.92 50.68 3.67 46.00

To examine transfer across data distributions, we apply the same candidate settings to a disjoint COCO subset:

R2-Table 2: Transferability of threshold settings to a disjoint COCO subset.

α\alpha + Gap CHAIR$_i$ ↓ CHAIR$_s$ ↓ Coverage ↑
0.05 + 0.10 9.69 25 53.60
0.10 + 0.10 10.82 27 55.20
0.15 + 0.10 11.78 28 53.20
0.05 + 0.00 11.54 33 54.00
0.05 + 0.05 12.53 27 55.20
0.05 + 0.15 10.21 26 54.00

It can bee seen the validation-selected setting remains best on both hallucination metrics on the disjoint COCO subset, supporting its transferability across data distributions within the same LVLM. However, fixed thresholds do have inherent limitations. Different LVLM architectures have distinct attention distributions and risk-score scales, and thus currently require separate calibration. We will explore adaptive thresholding to further improve cross-architecture applicability.


Q2: How should the trade-off between hallucination reduction and visual ground-truth coverage be balanced?

A2: Through further analysis, we found that some hallucinations exhibit attention patterns nearly indistinguishable from normal generation, which may introduce detection errors. Consequently, HALMES can become more conservative toward visually weak but correct objects, occasionally reducing Coverage.

This trade-off is controlled by the FPR budget α\alpha and hysteresis gap. As shown in R2-Table 1, our selected setting (α=0.05,Gap=0.10)(\alpha=0.05,\mathrm{Gap}=0.10) reduces Coverage by 2.45 pp relative to its best value, while achieving a 14 pp reduction in Hal compared with the highest-coverage setting. We therefore regard it as a practical balance that substantially reduces hallucinations while limiting information loss.


Q3: Redundancy of the Δrelative\Delta_{\mathrm{relative}} column in Table 2.

A3: Thank you for pointing this out. We recognize that the absolute percentage-point improvement is sufficient and will remove the Δrelative\Delta_{\mathrm{relative}} column in the possible camera-ready version.


Q4: Can HALMES remain effective on a more native multimodal architecture such as Qwen3.5-9B?

A4: We additionally evaluate HALMES on Qwen3.5-9B, whose hybrid architecture differs substantially from the Qwen3-based backbones evaluated in the original submission. After lightweight model-specific detector training, HALMES achieves 88.18 AUROC and 19.09 FPR, as shown in R2-Table 3. Although Accuracy and Recall are moderately lower than on the original LVLMs, AUROC and FPR remain high, indicating that hallucination-related attention patterns are still detectable on Qwen3.5-9B.

R2-Table 3: Hallucination-segment detection performance on Qwen3.5-9B. All metrics are reported as percentages.

Model AUROC ↑ Accuracy ↑ Recall ↑ PR-AUC ↑ FPR ↓
Qwen3.5-9B 88.18 81.15 82.38 88.44 19.09

To further examine whether this detection capability translates into effective mitigation, we adapt all five CD methods to Qwen3.5-9B and evaluate HALMES on a COCO subset:

R2-Table 4: Object-hallucination mitigation results of HALMES on Qwen3.5-9B over COCO subset. All metrics are reported as percentages; Δ\Delta denotes the absolute percentage-point improvement over the corresponding full-stage CD method.

Method CHAIR$_i$ ↓ CHAIR$_s$ ↓ Coverage ↑
Base
Nucleus 9.72 33.33 63.13
Full-Stage Contrastive Decoding
VCD 8.78 28.12 63.12
M3ID 9.53 27.08 64.80
AVISC 9.14 28.12 65.75
SID 7.98 26.04 65.58
Self-Aug 9.74 29.17 66.81
HALMES (Ours)
HALMES+VCD 7.64 26.37 62.87
HALMES+M3ID 7.87 22.92 63.06
HALMES+AVISC 6.40 21.88 68.61
HALMES+SID 7.57 25.77 62.00
HALMES+Self-Aug 7.32 26.60 67.45
Δ\Delta absolute (pp) vs. corresponding CD method
HALMES+VCD +1.14 +1.75 -0.25
HALMES+M3ID +1.65 +4.17 -1.74
HALMES+AVISC +2.74 +6.25 +2.86
HALMES+SID +0.41 +0.27 -3.58
HALMES+Self-Aug +2.42 +2.57 +0.64

It can be found that HALMES improves all CHAIR comparisons across the five CD methods. Notably, HALMES+AVISC improves CHAIR$_i$, CHAIR$_s$, and Coverage by 2.74, 6.25, and 2.86 pp, respectively. These results demonstrate that HALMES remains effective on Qwen3.5-9B, providing further evidence of its applicability to native multimodal architectures.


We hope our responses and additional experiments have addressed your concerns. We would be grateful for any further feedback that could help us improve this work. And we are more than happy to include all these discussions in the possible camera-ready version of this work.

Reviewer ZKn1 · CommentOpenReview ↗

Official Comment by Reviewer ZKn1

Thank you for the authors’ clarification. I found this paper interesting and meaningful. My main concern when reading the paper was the generalizability of the proposed method. Specifically, I was concerned that additional datasets might be required to determine θhigh\theta_{\text{high}} and θlow\theta_{\text{low}}, and that the method might not generalize well across different model architectures.

The authors’ responses to these two concerns have addressed my reservations. In particular, the demonstrated transferability across data distributions within the same LVLM is meaningful and strengthens the practical value of the proposed method. Therefore, I am willing to raise my rating to 5. If possible, I hope the authors can include these results in the final version.

Authors · CommentOpenReview ↗

We sincerely thank you for your constructive and thoughtful comments. Your valuable suggestions have been highly helpful in improving the paper and strengthening the quality of its final version. We are pleased that the additional experiments have addressed your concerns, and we greatly appreciate your recognition of the practical value of our work. This recognition means a great deal to us and provides strong encouragement to continue refining and advancing this line of research. We are also sincerely grateful for your decision to raise the rating. Given the opportunity, we will incorporate these results and the corresponding explanations into the final version. Thank you again for your time, careful review, and valuable feedback.

Reviewer NbG5OpenReview ↗
Rating
3/6
Confidence
4/5
Quality
2/4
Clarity
2/4
Significance
3/4
Originality
2/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper proposes HALMES, a small plug-and-play module for reducing hallucinations in large vision-language models. The main idea is simple: instead of applying contrastive decoding at every generation step, the model should only intervene when hallucination is likely. HALMES looks at the model’s internal attention features during generation. These features show how much the model is relying on the image, the text prompt, and the previously generated words. A small MLP classifier then predicts whether the recent generated token segment is risky or normal. If the risk is high, HALMES turns on an existing contrastive decoding method. If the risk is low, the model continues with normal decoding.

The paper claims that hallucinations can often be detected before the wrong object word is generated. It also claims that selective intervention is better than applying contrastive decoding all the time. The authors test HALMES with several contrastive decoding methods on datasets such as MSCOCO, AMBER, MMHal-Bench, and Bingo, and they report improvements in many settings.

Strengths and weaknesses

Strengths:

The paper identifies the weakness of existing contrastive decoding methods: applying intervention at every decoding step can harm outputs that were already correct. The token-segment-level idea is also meaningful because it tries to detect hallucination risk before the hallucinated noun is generated, instead of only identifying wrong nouns after generation. The attention features used in the method are intuitive and reasonably motivated, since visual attention, prompt attention, generated-text attention, text-visual balance, and attention entropy can reflect whether the model is properly grounded in the image. HALMES is also lightweight which helps to attached to several existing contrastive decoding methods. The experiments are reasonably broad, covering multiple LVLMs, benchmarks, and decoding baselines. The rescue and collateral-risk analysis is especially useful because it directly studies whether HALMES reduces the negative side effects of full-stage intervention.

Weaknesses:

  1. The contrastive decoding formulation is unclear. The paper introduces logits from a distorted input, but it does not clearly define how the distorted input is constructed within HALMES. It appears that HALMES inherits the distorted branch from existing CD baselines rather than developing a new one. This distinction is important and should be stated much more explicitly.

  2. The method depends heavily on CHAIR-style noun localization and MSCOCO-based training data. This raises concerns about generalization to non-object hallucinations, complex relational hallucinations, counting errors, OCR errors and reasoning hallucinations.

  3. The detector is architecture-sensitive. The cross-architecture transfer results show clear degradation and higher false positive rates, suggesting that HALMES may need model-specific training/calibration. This weakens the plug-and-play claim.

  4. The paper reports average inference speed over 100 test samples, but it does not clearly show how often HALMES actually activates the hallucination detector/intervention. Since many samples may not trigger contrastive decoding, the average latency may hide the true cost of the method when intervention is activated. The authors should report the trigger rate, the average number/percentage of triggered decoding steps, and separate inference times for triggered and non-triggered samples. This would make the efficiency analysis more transparent.

  5. The threshold selection may also be unstable. HALMES uses fixed high and low thresholds to decide when to turn contrastive decoding on or off. These thresholds are manually calibrated using an FPR budget. However, different models, datasets, prompts or decoding methods may need different thresholds.

  6. The results are not always consistently positive. HALMES improves many settings, but sometimes it lowers object coverage, reduces Bingo scores, or gives weaker gains for some contrastive decoding methods. The paper should better explain when HALMES fails and why.

Questions
  1. In Eq. 2, what exactly are (I') and (x')? For each contrastive decoding backbone used in the experiments, please clearly specify how the distorted image, distorted text, or contrastive branch is constructed.

  2. Does HALMES introduce a new contrastive decoding formulation, or does it only decide when to activate existing contrastive decoding methods? Please clarify the exact technical novelty beyond the gating module.

  3. During inference, is the contrastive branch computed only when HALMES activates intervention, or is it computed at every decoding step and only selectively applied? This is important for understanding the real inference cost.

  4. How often does HALMES activate contrastive decoding during inference? Please report the sample-level trigger rate and the percentage of decoding steps where intervention is active.

  5. Please provide separate inference-time results for non-triggered samples/steps and triggered samples/steps. The current average over 100 samples may hide the true cost when HALMES activates contrastive decoding.

  6. How sensitive is HALMES to the thresholds θhigh\theta_{high}, θlow\theta_{low}, and the window size (K)? Can the same threshold/window setting transfer across datasets, decoding methods, and LVLM architectures?

  7. Since cross-architecture transfer gives high false positive rates, how practical is HALMES for a new LVLM? Does each new LVLM require collecting a new hallucination-segment dataset and training/calibrating a new detector?

  8. How does HALMES handle hallucinations beyond object nouns, such as wrong attributes, wrong counts (such as pixmo counting dataset or any counting dataset), OCR mistakes or reasoning errors?

  9. Some results show reduced object coverage or degraded response quality. Can the authors provide more analysis of the trade-off between hallucination reduction and informativeness?

  10. Please provide confidence intervals, error bars, or statistical significance tests for the main benchmark results. Are the reported gains stable across random seeds and different sampled evaluation subsets?

Limitations

The authors discuss some limitations, including fixed thresholding, false activations, and robustness across models/scenarios. However, the limitations could be strengthened by more clearly discussing the need for model-specific calibration, weaker cross-architecture transfer, limited evaluation beyond object hallucination, and the trade-off between hallucination reduction and response informativeness.

Final justification

The rebuttal substantially improves the technical clarity of the paper. The authors clearly explain the baseline-specific contrastive branches, selective logit recombination, window-size selection, threshold settings, trigger behavior, and training-sample statistics. The additional experiments on disjoint evaluation subsets, non-COCO training and broader benchmarks also address most of my original concerns and provide stronger evidence for the effectiveness of HALMES in object-hallucination mitigation.

However, I still have some concerns regarding the overstated broader generalization claims. The results beyond object hallucination remain preliminary and mixed, with several degradations on MathVista, PathVQA, and some MME categories. Only 9 of the 30 original comparisons remain statistically significant after correction, and the method still requires model-specific detector training and calibration. Therefore, the evidence currently supports HALMES most strongly for in-domain object-hallucination mitigation, while its broader cross-domain benefits should be stated more cautiously.

Overall, the authors responded constructively and provided substantial additional evidence. Their commitment to fully release the code and data should also support independent verification of the results. I therefore increase my rating from Reject to Borderline Reject, while retaining the above concerns.

Formatting concerns

I did not notice any major formatting or anonymity violations. The paper appears to use an anonymous submission format and includes the standard NeurIPS-style submission/footer information. I also did not observe obvious issues with page structure, tables, figures or references.

8 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We sincerely thank the reviewer for the detailed and constructive feedback. We are encouraged that the reviewer recognizes the importance and practical value of shifting contrastive decoding from indiscriminate full-stage intervention to targeted intervention on hallucination-prone token segments.

We have carefully addressed the concerns through additional clarifications and experiments. We hope the following responses resolve your concerns, and we respectfully ask if you're comfortable to reconsider the rating. Below, we provide detailed responses to all the comments:


Q1: Does HALMES introduce a new contrastive branch, and what is its exact technical novelty?

A1: HALMES does not introduce a new contrastive branch or modify the formulation of any CD backbone. Instead, it fully inherits the original contrastive branch, hyperparameters, and logit-adjustment rule of each method. In Eq. (2), I′I' and x′x' are generic notations for the alternative visual or textual inputs defined by the corresponding CD method. Different CD methods construct their contrastive signals in different ways, such as perturbing the image or modifying the textual condition. Eq. (2) serves only as a unified abstraction. We will provide a clearer explanation of this distinction in the possible camera-ready version.

The technical novelty of HALMES lies in two aspects: (1) token-segment-level hallucination detection, which models the evolving attention patterns over preceding token segments to identify hallucination risk before the hallucinated noun is generated, rather than performing isolated post-hoc noun classification; (2) targeted contrastive decoding paradigm, which uses this segment-level risk monitoring to convert indiscriminate full-stage intervention into targeted intervention on hallucination-prone segments, thereby reducing unnecessary perturbations to normal generation.


Q2: Is the contrastive branch computed only after HALMES is activated?

A2: In the original implementations of all evaluated full-stage CD methods, the contrastive branch is computed alongside the original branch throughout generation, since logit-level contrastive recombination is performed at every decoding step. HALMES preserves this computation pattern and only uses the estimated hallucination risk to decide whether the already available logits should be contrastively recombined at the current step. Therefore, triggered and non-triggered steps differ only in whether the recombination is applied, rather than whether the contrastive branch is computed.


Q3: How frequently is HALMES activated, and how do triggered and non-triggered samples differ in latency?

A3: As clarified in A2, both triggered and non-triggered samples compute the original and contrastive branches throughout generation; activation only determines whether the lightweight logit-level contrastive recombination is applied. Therefore, the current average latency over 100 samples does not hide a substantially higher branch-computation cost when HALMES is activated.

We further report the activation statistics and latency results, averaged across the five evaluated CD methods:

R1-Table 1: Activation frequency and latency comparison of HALMES.

LVLM Sample-level trigger rate Active-step ratio Triggered samples Non-triggered samples Difference
Qwen3VL-8B 66.0% 71.31% 11.3205 s/sample 11.2951 s/sample +0.0254 s
InternVL3.5-8B 65.6% 73.17% 12.0134 s/sample 11.8713 s/sample +0.1421 s

It can be seen that the measured latency difference between triggered and non-triggered samples is below 0.15 s, further confirming that activation does not introduce a substantial additional inference cost.


Q4: How well does HALMES generalize beyond object hallucinations?

A4: Our primary focus is object hallucination, and we therefore use CHAIR-localized object nouns from MSCOCO to construct the training data. Nevertheless, HALMES models hallucination-precursor patterns in internal attention dynamics, rather than specific object identities. We hypothesize that these signals may transfer to other hallucination types. As reported in the original submission, we evaluated HALMES on multiple categories in MMHal-Bench. To further assess this transferability, we additionally conducted experiments on multiple hallucination-related categories in MME [1]:

R1-Table 2: Relative MME score changes under complete-response prompting. Each subset has a maximum score of 200; positive values indicate improvement.

Qwen3VL-8B

CD Existence Count Position Color OCR Reasoning Total
VCD 0.00% +2.86% +6.74% -5.00% +4.41% +3.07% +1.67%
M3ID 0.00% 0.00% +9.78% +2.70% +8.45% +5.31% +4.14%
AVISC 0.00% 0.00% +9.78% -2.56% 0.00% +8.56% +2.22%
SID 0.00% +3.74% 0.00% 0.00% +4.23% +4.45% +2.00%
Self-Aug +2.63% 0.00% +13.95% 0.00% -4.23% -1.28% +1.45%

InternVL3.5-8B

CD Existence Count Position Color OCR Reasoning Total
VCD +2.63% +0.99% +12.22% -7.69% +4.62% +4.81% +2.43%
M3ID +2.70% -2.80% +9.57% -3.42% 0.00% +7.54% +1.85%
AVISC 0.00% +9.78% -1.02% -0.90% +4.62% +4.92% +2.63%
SID 0.00% +1.98% -1.00% +2.86% -4.62% +6.00% +0.77%
Self-Aug +2.63% +1.94% +1.03% +0.94% -4.41% +2.92% +0.83%

These results indicate that HALMES can also mitigate diverse non-object hallucinations to some extent. The experiments further show that HALMES improves commonsense-reasoning performance when combined with existing CD methods.


Q5: How sensitive is HALMES to θhigh,θlow\theta_{\mathrm{high}}, \theta_{\mathrm{low}}, and the window size KK, and can these settings transfer across datasets, CD methods, and LVLM architectures?

A5: Table 4 of the paper analyzes the sensitivity to different combinations of θhigh\theta_{\mathrm{high}} and θlow\theta_{\mathrm{low}}. For each LVLM, HALMES is trained and calibrated only once, and the same detector and parameter settings are used across all evaluated datasets, prompt styles, and five CD methods, without scenario-specific retraining or recalibration. The consistent gains in our main results therefore support their transferability within the same LVLM.

We further evaluate the sensitivity to window size on a COCO subset using Qwen3VL with VCD:

R1-Table 3: Sensitivity of HALMES to the window size KK. All metrics are reported as percentages.

KK CHAIR$_i$ ↓ CHAIR$_s$ ↓ Coverage ↑
5 10.85 27 54.00
10 11.52 27 54.40
15 9.02 23 55.60
20 9.09 25 55.20
25 11.14 27 55.20

Because HALMES aims to issue warnings before hallucinated tokens emerge, we set KK slightly below the average training-segment length (about 20 tokens), balancing early detection with sufficient context. The results validate this design, with K=15K=15 achieving the best overall performance. Due to space limitations, please refer to response to Reviewer ZKn1 (Q1) for more details. Thanks!


Q6: How practical is HALMES for a new LVLM, and does it require architecture-specific training and calibration?

A6: Different LVLMs usually exhibit distinct attention distributions. The degraded cross-architecture transfer results further confirm this discrepancy. Moreover, LVLMs may differ in their numbers of layers and attention heads, preventing direct reuse of the same detector.

Therefore, a new LVLM currently requires modest model-specific data to train and calibrate the lightweight detector, after which HALMES supports plug-and-play use across diverse CD methods.


Q7: Why can HALMES occasionally reduce object coverage or response quality while mitigating hallucinations?

A7: Through sample-level analysis, we found that hallucination-related attention patterns are not fully consistent across cases, and some hallucinations exhibit attention patterns nearly indistinguishable from normal generation. HALMES may therefore miss risky segments or falsely activate on visually weak but correct objects, suppressing valid mentions and reducing coverage.

Response quality reflects both visual faithfulness and informativeness. By suppressing uncertain details, HALMES may reduce hallucinations but occasionally remove correct information, resulting in a slightly less informative response and a lower overall quality score. This reflects an inherent trade-off between hallucination mitigation and information preservation. As shown in Table 4 of the paper, reducing the FPR budget while maintaining a sufficient threshold gap decreases coverage by 2.45 pp relative to its best value, but reduces the hallucination rate by 14 pp. We therefore consider the selected HALMES configuration to achieve the intended balance between hallucination reduction and information preservation.


Q8: Are the reported gains statistically significant and stable across random seeds and sampled subsets?

A8: We use 10,000 paired bootstrap resamples for 95% confidence intervals, reported as asymmetric error bars, and paired randomization tests with Holm correction. On COCO, 26/30 comparisons favor HALMES, with 9 remaining significant after correction, while no Coverage change is significant. The gains also remain stable across three random seeds and independently sampled evaluation subsets. Due to space limitations, detailed results will be provided in an official comment.

Reference:

[1] MME: A Comprehensive Evaluation Benchmark for Multimodal Large Language Models.

Authors · CommentOpenReview ↗

Response to Reviewer NbG5

Additional Robustness Results Across Random Seeds and Disjoint Evaluation Subsets

1. Stability across random seeds

Given the limited rebuttal period, we conducted this analysis on a fixed 100-image subset of the COCO evaluation set used in our main experiments and reran all ten backbone–CD combinations under three different decoding seeds. For each run, HALMES and the corresponding full-stage CD method used the same decoding seed. We report the mean and standard deviation across the three runs.

Table 1: Mean improvements and standard deviations across three decoding seeds on a fixed 100-image COCO subset.

Backbone CD Method Δ\DeltaCHAIR$_i$ ↑\uparrow Δ\DeltaCHAIR$_s$ ↑\uparrow Δ\DeltaCoverage ↑\uparrow
InternVL3.5-8B VCD +2.18±0.75+2.18 \pm 0.75 +2.00±0.73+2.00 \pm 0.73 +0.64±1.80+0.64 \pm 1.80
InternVL3.5-8B M3ID +1.46±0.65+1.46 \pm 0.65 +3.00±1.00+3.00 \pm 1.00 +0.38±0.76+0.38 \pm 0.76
InternVL3.5-8B AVISC +1.27±0.55+1.27 \pm 0.55 +5.00±1.54+5.00 \pm 1.54 +0.76±0.66+0.76 \pm 0.66
InternVL3.5-8B SID +1.24±0.48+1.24 \pm 0.48 +3.67±1.08+3.67 \pm 1.08 −1.27±0.88-1.27 \pm 0.88
InternVL3.5-8B Self-Aug +0.28±0.26+0.28 \pm 0.26 +2.67±0.58+2.67 \pm 0.58 −1.07±0.58-1.07 \pm 0.58
Qwen3VL-8B VCD +1.13±0.44+1.13 \pm 0.44 +2.67±0.83+2.67 \pm 0.83 +0.38±2.13+0.38 \pm 2.13
Qwen3VL-8B M3ID +2.86±0.69+2.86 \pm 0.69 +6.67±2.08+6.67 \pm 2.08 +1.40±0.88+1.40 \pm 0.88
Qwen3VL-8B AVISC +2.19±0.59+2.19 \pm 0.59 +5.33±2.52+5.33 \pm 2.52 −1.56±0.79-1.56 \pm 0.79
Qwen3VL-8B SID +0.22±0.14+0.22 \pm 0.14 +4.67±2.52+4.67 \pm 2.52 −0.42±1.23-0.42 \pm 1.23
Qwen3VL-8B Self-Aug +0.92±0.35+0.92 \pm 0.35 +0.67±0.43+0.67 \pm 0.43 +1.27±1.45+1.27 \pm 1.45

The three-seed averages favor HALMES on both hallucination metrics in all ten backbone–method combinations. Moreover, the mean improvement exceeds the corresponding standard deviation in every combination, indicating that the observed gains are larger than the typical seed-induced variation. Across all combinations, HALMES improves CHAIR$_i$ and CHAIR$_s$ by 1.38 pp and 3.64 pp, with average standard deviations of 0.49 pp and 1.33 pp, respectively, while Coverage remains nearly unchanged (+0.05 pp). These results support consistent positive gains across decoding seeds without a systematic change in Coverage.

2. Stability across independently sampled evaluation subsets

To examine sensitivity to sample selection, we additionally evaluated HALMES on a non-overlapping 100-image subset from COCO val2014 and a non-overlapping 500-sample subset from AMBER. Neither subset overlaps with the samples used in our main evaluation.

Table 2: Results on an independently sampled 100-image COCO subset.

Backbone CD Method Δ\DeltaCHAIR$_i$ ↑\uparrow Δ\DeltaCHAIR$_s$ ↑\uparrow Δ\DeltaCoverage ↑\uparrow
InternVL3.5-8B VCD +2.02 +2.00 +2.67
InternVL3.5-8B M3ID +0.38 +2.00 +0.76
InternVL3.5-8B AVISC +2.53 +8.00 −3.05
InternVL3.5-8B SID +2.97 +5.00 +0.38
InternVL3.5-8B Self-Aug +0.87 +5.00 −0.76
Qwen3VL-8B VCD +4.00 +7.00 +1.53
Qwen3VL-8B M3ID +3.20 +9.00 +2.29
Qwen3VL-8B AVISC +0.53 +1.00 +1.91
Qwen3VL-8B SID +1.90 +6.00 +0.76
Qwen3VL-8B Self-Aug +0.33 +3.00 +0.76

On the disjoint COCO subset, HALMES improves both CHAIR metrics in all 10/10 backbone–method combinations and Coverage in 8/10 combinations. The average improvements are 1.87 pp in CHAIR$_i$, 4.80 pp in CHAIR$_s$, and 0.73 pp in Coverage, reproducing the overall trend of the main results.

Table 3: Results on an independently sampled 500-example AMBER subset.

Backbone CD Method Δ\DeltaCHAIR ↑\uparrow Δ\DeltaCover ↑\uparrow Δ\DeltaCog ↑\uparrow Δ\DeltaHal ↑\uparrow
InternVL3.5-8B VCD +0.48 −1.21 −0.17 +3.80
InternVL3.5-8B M3ID +0.65 −0.98 +0.20 +4.00
InternVL3.5-8B AVISC +1.39 +1.05 +0.12 +1.80
InternVL3.5-8B SID +0.95 −2.52 −0.12 +2.80
InternVL3.5-8B Self-Aug +0.27 +1.27 +0.19 +3.20
Qwen3VL-8B VCD +0.67 +0.73 −0.34 −1.80
Qwen3VL-8B M3ID +0.54 −0.05 −0.22 +4.40
Qwen3VL-8B AVISC +0.12 0.00 −0.04 +0.40
Qwen3VL-8B SID −0.36 −1.01 +0.32 −0.60
Qwen3VL-8B Self-Aug +0.24 +0.23 +0.02 −0.80

On the disjoint AMBER subset, HALMES improves CHAIR in 9/10 combinations and Hal in 7/10 combinations, with average gains of 0.50 pp and 1.72 pp, respectively. Coverage shows a pattern similar to the main results, with modest decreases for some CD methods.


Overall, these results show that HALMES delivers consistent hallucination-reduction gains across decoding seeds and remains effective across independently sampled evaluation subsets. We hope these additional experiments have effectively addressed your concern.

Reviewer NbG5 · CommentOpenReview ↗

Thank you for the detailed rebuttal. I still have several points that need clarification.

  1. "We will provide a clearer explanation of this distinction in the possible camera-ready version." This does not fully address my concern. I asked for the exact construction of (I') and (x'). The authors admit that HALMES does not design a new contrastive branch, but they still do not specify how the contrastive branch is constructed for each baseline. The unified Eq. (2) is also somewhat misleading because not every method simply uses a distorted (I') or (x'). For example, M3ID contrasts image-conditioned and language-prior predictions, AVISC uses blind-token-biased logits, and SID modifies internal visual-token processing.

  2. In Lines 561-563, the paper states that "K is mainly determined according to the length distribution of token segments in the training data." However, in the rebuttal, the authors mention using a fixed value of (K=15). Could the authors please clarify this? Is (K=15) used for all experiments, or is it selected differently for different settings?

  3. In Lines 77-78 and Lines 311-312, the paper describes HALMES as providing "on-demand correction." While the correction itself is applied on demand, the rebuttal clarifies that both branches are still computed throughout generation. Please report the exact values of (θhigh),(θlow)(\theta_{\text{high}}), (\theta_{\text{low}}), and the warm-up/cool-down counter limits for each LVLM. Also, please clarify what "trend-aware" means, since Algorithm 1 does not appear to impose an explicit positive-trend condition.

  4. The detector is trained using only 5,000 COCO images with CHAIR-derived object-noun labels. I appreciate that the authors additionally evaluated HALMES on multiple datasets to demonstrate some level of generalization. However, could the authors report the exact number of positive and negative token-segment training samples, provide learning curves as the training-set size increases, and, if possible, include results on non-COCO or category-disjoint training/test splits? In addition, could the authors explain how HALMES could be useful beyond image captioning or hallucination-specific benchmarks, for example on video understanding (LVBench, VideoMME, LongVideoBench), coding (MBPP, HumanEval), mathematics (GSM8K, MATH500, MathVista, VideoMath), or medical benchmarks (PathVQA, PMC-VQA, MedXQA-MM)? My original question, "How does HALMES handle hallucinations beyond object nouns, such as wrong attributes, wrong counts, OCR mistakes, or reasoning errors?", is still not fully answered.

Comments on the paper

2 comments
Area Chair dgVC · CommentOpenReview ↗

Quick reminder

Dear reviewers,

Thanks to those who have already joined the discussion. For anyone who has not yet, the authors’ rebuttals are available. Please take a moment to read them and join the discussion.

Best,

AC

Authors · CommentOpenReview ↗

General Response

For clarity, we refer to Reviewers NbG5, ZKn1, and ZNDY as R1, R2, and R3, respectively, in the following response.

We sincerely thank all reviewers and the Area Chair for their time, careful evaluation, constructive feedback, and thoughtful consideration. We are particularly encouraged by the reviewers’ recognition of the significance and practical value of HALMES’s central idea: shifting contrastive decoding from indiscriminate full-stage intervention to targeted intervention on hallucination-prone token segments.

We have carefully responded to all individual comments through detailed technical clarifications, additional controlled analyses, and substantial new experiments. Below, we summarize the core contributions of HALMES, the experimental evidence added during the rebuttal, and the scope and broader applicability of our work.


Core Contributions

  1. Token-Segment-Level Hallucination Detection: HALMES reformulates hallucination detection from isolated, post-hoc classification of generated object nouns into real-time identification of hallucination-prone token segments. By modeling the evolving internal attention patterns over preceding tokens, HALMES enables early hallucination warning before the corresponding hallucinated object noun is generated.

  2. Risk-Guided Targeted Contrastive Decoding Paradigm: HALMES proposes a new risk-guided targeted contrastive decoding paradigm that transforms indiscriminate full-stage intervention into targeted correction on hallucination-prone token segments. Rather than introducing a new contrastive branch, HALMES preserves the original formulation, hyperparameters, and logit-adjustment rule of each CD method, while determining when its correction should be applied. Controlled comparisons with random and periodic activation further demonstrate that the gains arise from risk-guided localization, rather than merely reducing the frequency of contrastive decoding.

  3. Lightweight and Extensible Integration: HALMES employs a lightweight detector and can be integrated with diverse contrastive decoding methods. Once trained and calibrated for an LVLM, the same detector and inference settings are reused across datasets, prompt styles, and CD methods without scenario-specific recalibration. Results across Qwen3VL-8B, InternVL3.5-8B, and Qwen3.5-9B further demonstrate the applicability of the proposed paradigm to different LVLM architectures.


Updates of Experimental Results During the Rebuttal

  • Controlled validation of risk-guided activation: Added random and periodic activation baselines to isolate the value of HALMES’s hallucination-risk signal from the effect of simply applying CD less frequently (R3).

  • Component and parameter analyses: Added leave-one-feature-out ablations, training-data scaling results, window-size sensitivity, threshold sensitivity, and cross-distribution threshold-transfer experiments (R1, R2, R3).

  • Efficiency and generation behavior: Added sample-level trigger rates, active-step ratios, separate latency results for triggered and non-triggered samples, response-length analysis, abstention/refusal rate, and incomplete-answer rate (R1, R3).

  • Robustness and reproducibility: Added confidence intervals, corrected statistical significance tests, three-seed stability evaluations, and evaluations on independently sampled subsets (R1).

  • Broader architectural and data evaluation: Added experiments on Qwen3.5-9B and fully non-COCO training on AMBER, including held-out AMBER detection evaluation and evaluation of object-hallucination mitigation on COCO using the AMBER-trained detector (R1, R2).

  • Evaluation beyond the primary setting: Added results on MME, MathVista, and PathVQA to investigate whether the learned risk patterns and selective intervention mechanism can also provide benefits beyond object-hallucination benchmarks (R1, R3).


Scope and Broader Applicability

HALMES primarily targets object hallucination, which is a common and representative failure mode in LVLM generation. Accordingly, HALMES is trained with object-hallucination supervision, and our main claims and empirical evaluation focus on detecting precursor token segments before incorrect object mentions and selectively intervening to mitigate object hallucinations.

Beyond this primary scope, the original results on MMHal-Bench and the additional experiments on MME, MathVista, and PathVQA provide encouraging preliminary evidence that the learned hallucination-risk patterns and selective intervention can benefit attribute, counting, position, OCR, reasoning, mathematical, and medical tasks to some extent. If given the opportunity, we will present these findings in the final paper as evidence of the potential extensibility of HALMES.


We again sincerely thank all reviewers and the Area Chair for their time, constructive feedback, and thoughtful consideration.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Missing a submission?

Loading the discussion…