Pan-FM: A Pan-Organ Foundation Model with Saliency-Guided Masking for Missing Robustness
Qiangqiang Wu, Grace McIlvain, Zhou Yu, Junhao Wen
TL;DR. This paper proposes Pan-FM, a pan-organ foundation model pre-trained on imaging from seven organs (Brain, Heart, Adipose, Liver, Kidney, Spleen, and Pancreas) under realistic missing-organ scenarios.
Abstract. Foundation models (FMs) have shown great promise in medical imaging, but most FMs are trained on unimodal data within isolated domains, such as brain MRI alone. Human aging and disease arise through coordinated biological processes across organs, therefore motivating multimodal FMs that learn whole-body representations. A key challenge, however, is that real-world multimodal biomedical data are often missing not at random, which can reduce power, limit generalizability, and introduce bias. We propose Pan-FM, a pan-organ foundation model pre-trained on imaging from seven organs (, , , , , , and ) under realistic missing-organ scenarios. Pan-FM uses a unified backbone that handles organ missingness during both training and inference, and is pre-trained with masking-based self-distillation. We find that naive multimodal pre-training leads to dominant-organ shortcut learning bias, with the model over-relying on dominant organs such as adipose and heart. To address this, we introduce Saliency-Guided Masking (SGM), which uses the model attention distribution to adaptively mask dominant organs during pre-training, thus encouraging more balanced cross-organ, whole-body learning. Notably, SGM introduces negligible computational overhead and can be seamlessly integrated into existing self-supervised learning frameworks to improve multi-organ representation learning. On the UK Biobank, Pan-FM achieves stronger prediction across 13 disease categories and 14 single disease entities than single-organ and multi-organ baselines, with improved robustness under missing-organ settings. Pan-FM serves as a scalable solution to realistic modality-missingness in multimodal learning in computational, systems and clinical neuroscience, and as a step toward more generalizable whole-body FMs. Codes are available at https://github.com/LABS-lab/Pan-FM.git.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:43 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
The paper introduced an imaging foundation model that covers several organs at once, and uses a saliency-guided masking proposed mechanism to suppress shortcuts and bias towards dominant organs.
The reviews are generally supportive and informative. Overall, the reviewers appreciate the motivation of the paper, and the practical relevance. The novelty is also mentioned as being resonable, and the paper is clear. Although there are some concerns about evaluation, it's pretty reasonable.
The reviewers did raise some (somewhat serious) concerns that should be addressed.
FMs are important especially for their potential for generalization, and it's quite unclear how this will perform on diverse tasks, datasets, centers, scanners, etc. The main evaluation seems UKB focused. Statistical uncertainty is also not reported, making it hard to assess the results as well.
The main contribution, SGM, was also somewhat unclear tot he reviewers, at least they would have appreciated more evaluation and interpretability of it. From my look, some of this is in the appendix, but it would be good for the authors to highlight it, point to it better int he paper, and describe it in the rebuttal.
The representational scope also seems limited since inputs are low-dimensional. Since this depends on some feature extraction, it can a-priori miss important features, depending on the downstream goals. This could use evaluation, as pointed out by several reviewers.
Similarly, the reviewers would like better ablations (CAPE) and baselines.
Overall, I agree with the reviewers that this seems promissing. Several, some potentially-serious, concerns remain, and should be given rigorous attention in the rebuttal.
Final justification
The authors provided a rigorous rebuttal and discussion, and engaged with the reviewers. Many of the important issues were resolved, and the paper had received a promissing score to begin with. I believe minor concerns remain, but the paper should clealry be accepted.
One lingering concern are two hallucinated references. I judge these to be minor issues, but something has clearly happened in the process and the authors should definitely revise.
@article{jiao2024usfm,
author = {Jiao Jiao et al.},
title = {USFM: A universal ultrasound foundation model generalized to tasks and organs within 15 populations},
journal = {Medical Image Analysis},
year = {2024}
}
The title in the citation is incorrect [1.2.5]. The actual title of the paper published by Jing Jiao et al. in Medical Image Analysis (2024) is 'USFM: A universal ultrasound foundation model generalized to tasks and organs towards label efficient image analysis'.
@article{kim2024foundation,
author = {Chanwoo Kim et al.},
title = {A foundation model for clinical-grade dermatology},
journal = {Nature Medicine},
volume = {400},
year = {2024},
pages = {401}
}
The title 'A foundation model for clinical-grade dermatology' does not exist. The actual 2024 paper in Nature Medicine by Chanwoo Kim et al. is titled 'Transparent medical image AI via an image–text foundation model grounded in medical literature' (Nature Medicine, Vol. 30, Issue 4, pp. 1154–1165). Additionally, Nature Medicine volume 400 is incorrect, as volume 30 corresponds to 2024.
Read meta-review
Meta-review
The paper introduced an imaging foundation model that covers several organs at once, and uses a saliency-guided masking proposed mechanism to suppress shortcuts and bias towards dominant organs.
The reviews are generally supportive and informative. Overall, the reviewers appreciate the motivation of the paper, and the practical relevance. The novelty is also mentioned as being resonable, and the paper is clear. Although there are some concerns about evaluation, it's pretty reasonable.
The reviewers did raise some (somewhat serious) concerns that should be addressed.
FMs are important especially for their potential for generalization, and it's quite unclear how this will perform on diverse tasks, datasets, centers, scanners, etc. The main evaluation seems UKB focused. Statistical uncertainty is also not reported, making it hard to assess the results as well.
The main contribution, SGM, was also somewhat unclear tot he reviewers, at least they would have appreciated more evaluation and interpretability of it. From my look, some of this is in the appendix, but it would be good for the authors to highlight it, point to it better int he paper, and describe it in the rebuttal.
The representational scope also seems limited since inputs are low-dimensional. Since this depends on some feature extraction, it can a-priori miss important features, depending on the downstream goals. This could use evaluation, as pointed out by several reviewers.
Similarly, the reviewers would like better ablations (CAPE) and baselines.
Overall, I agree with the reviewers that this seems promissing. Several, some potentially-serious, concerns remain, and should be given rigorous attention in the rebuttal.
Final justification
The authors provided a rigorous rebuttal and discussion, and engaged with the reviewers. Many of the important issues were resolved, and the paper had received a promissing score to begin with. I believe minor concerns remain, but the paper should clealry be accepted.
One lingering concern are two hallucinated references. I judge these to be minor issues, but something has clearly happened in the process and the authors should definitely revise.
@article{jiao2024usfm,
author = {Jiao Jiao et al.},
title = {USFM: A universal ultrasound foundation model generalized to tasks and organs within 15 populations},
journal = {Medical Image Analysis},
year = {2024}
}
The title in the citation is incorrect [1.2.5]. The actual title of the paper published by Jing Jiao et al. in Medical Image Analysis (2024) is 'USFM: A universal ultrasound foundation model generalized to tasks and organs towards label efficient image analysis'.
@article{kim2024foundation,
author = {Chanwoo Kim et al.},
title = {A foundation model for clinical-grade dermatology},
journal = {Nature Medicine},
volume = {400},
year = {2024},
pages = {401}
}
The title 'A foundation model for clinical-grade dermatology' does not exist. The actual 2024 paper in Nature Medicine by Chanwoo Kim et al. is titled 'Transparent medical image AI via an image–text foundation model grounded in medical literature' (Nature Medicine, Vol. 30, Issue 4, pp. 1154–1165). Additionally, Nature Medicine volume 400 is incorrect, as volume 30 corresponds to 2024.
1 comment
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 2/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper proposes Pan-FM, a pan-organ foundation model for seven organs, aiming to address the common problem of missing organs in real-world biomedical data. Pan-FM introduces a saliency-guided masking strategy, which adaptively masks dominant organs according to the model’s attention distribution, thereby encouraging the model to learn more balanced cross-organ representations. Experimental results show that Pan-FM overall outperforms multiple self-supervised learning baselines across 13 disease groups and 14 individual disease prediction tasks, and demonstrates stronger robustness under both single-organ and multi-organ missing scenarios.
Strengths and weaknesses
Strengths:
- Pan-FM focuses on the problem of missing organs in multi-organ medical imaging foundation models, which aligns well with real clinical scenarios and has strong practical value.
- Pan-FM observes the dominant-organ shortcut learning bias in multi-organ self-supervised pre-training, and proposes Saliency-Guided Masking to mitigate this issue, which also shows a certain degree of transferability.
- Pan-FM conducts robustness evaluations across multi-disease groups, individual disease prediction tasks, and different organ-missing settings. The results show that Pan-FM has advantages in both overall prediction performance and missing-organ robustness.
Weaknesses:
- The generalization validation is limited. Since Pan-FM aims to serve as a multi-organ foundation model for real clinical scenarios, validation on a single data source is insufficient to fully demonstrate its generalizability across centers, imaging devices, or populations.
- The input format is biased toward low-dimensional features rather than raw medical images. This may limit its direct comparability with existing vision-based medical foundation models.
- The core assumption of SGM is to use the attention distribution to measure organ importance. However, whether attention is stable and whether it truly corresponds to biologically meaningful organ contributions still require further validation.
Questions
- CAPE is used to balance the dimensionality across different organs. The author should clarify whether not balancing the organ dimensions would affect the results. An ablation study on CAPE is also missing.
- Figure 3 shows that adipose is the dominant organ, and removing it leads to a significant performance drop, while removing the pancreas has almost no effect. In Figure 4, w/o brain and liver has only a limited impact, and Pan-FM even underperforms DINOv2 w/o spleen. Does this suggest that using only a small subset of dominant organs can achieve performance nearly comparable to that obtained with all seven organs?
- The relative improvement over DINOv2, denoted by Δ, in the last row of Table 2 is somewhat unusual. A more common presentation would be to report the absolute improvement over the second-best method.
- In Figure 5(b), there are cases where the performance under single-organ removal is even lower than that under two-organ removal. For example, w/o Adipose=0.647 < w/o Adipose+Spleen=0.654. This raises concerns about the contribution of the complete multi-organ input.
- The paper lacks comparisons with recent methods (2024, 2025, and 2026). The baselines are mainly foundation models from the general vision domain, whereas direct comparisons with medical imaging foundation models are missing.
Limitations
Yes
Final justification
My major concerns still partly remain. Adding one external application is somewhat still limited, and direct quantitative measures are desired for illustrating the attention stability and biological implication. Therefore, my rating remains the same.
Formatting concerns
N/A
4 comments
Rebuttal
We thank the reviewer for their detailed and insightful feedback, and for recognizing the strong practical value of addressing missing organs, the dominant-organ shortcut learning bias and transferability of SGM, and the robust evaluation. We address each concern below.
Weaknesses
W1: Generalization is validated on a single data source, insufficient across centers, devices, or populations.
We thank the reviewer for this important concern. We have added an external evaluation on ADNI, which differs from UK Biobank in population, scanner fleet, acquisition protocol, recruitment, and disease prevalence. Please refer to USq3-W2/Q2 and h3iE-Q2 for the full experimental setup and implementation details.
| Backbone | Method | Val BalAcc | Test BalAcc, 5 folds | Test BalAcc mean ± std |
|---|---|---|---|---|
| MLP | Raw MUSE features | 0.870 ± 0.015 | 0.890, 0.865, 0.895, 0.915, 0.905 | 0.894 ± 0.017 |
| SVM | Raw MUSE features | 0.879 ± 0.023 | 0.900, 0.885, 0.920, 0.905, 0.905 | 0.903 ± 0.011 |
| ViT | Fine-tuning from scratch | 0.885 ± 0.011 | 0.870, 0.870, 0.875, 0.850, 0.860 | 0.865 ± 0.009 |
| ViT | DINOv2 pre-trained on UKBB | 0.893 ± 0.024 | 0.890, 0.890, 0.890, 0.920, 0.890 | 0.896 ± 0.012 |
| ViT | Pan-FM pre-trained on UKBB | 0.905 ± 0.011 | 0.910, 0.930, 0.915, 0.925, 0.925 | 0.921 ± 0.007 |
Using only brain features, with six of the seven organs absent, Pan-FM achieves 0.921 ± 0.007 test balanced accuracy, outperforming DINOv2 pre-training (0.896 ± 0.012), training from scratch (0.865 ± 0.009), and classical MLP and SVM baselines. No architectural modification is required. These results provide evidence that Pan-FM transfers across cohorts and imaging settings and remains effective under extreme organ missingness.
W2: The input is low-dimensional features rather than raw images, limiting comparability with vision medical FMs.
Thanks for raising the concern. The current study uses imaging-derived features to enable a controlled investigation of joint multi-organ representation learning under realistic organ missingness. Nevertheless, the learned Pan-FM representation is transferable across cohorts: as shown by the external ADNI evaluation in W1, our UK Biobank-pretrained multi-organ model transfers well to a single-organ brain cohort without architectural modification.
To directly assess whether Pan-FM and SGM extend beyond imaging-derived features, we further developed a raw-imaging version using seven available UK Biobank modalities: total-body DXA, cardiac cine MRI, brain T1 MRI, liver MRI, pancreas MRI, and left and right retinal OCT. Each modality is tokenized using a modality-specific 2D or 3D convolutional encoder, after which CAPE aggregates the resulting image tokens into a fixed set of organ tokens. The subsequent multi-organ Transformer and SGM are unchanged. In particular, SGM operates only on organ-level token groups and is therefore agnostic to whether these tokens originate from tabular features or raw images.
The raw-imaging cohort contains 137,716 subjects, more than the 40,689 subjects used in the current paper, and exhibits substantially more severe natural missingness. Only 1,350 subjects (1.0%) have all seven modalities, compared with 33% complete cases in the feature-based setting.
Preliminary linear-probing results show that Pan-FM consistently outperforms its DINOv2 counterpart under both natural missingness and additional organ dropout:
| Raw-imaging setting | AUROC | BalAcc |
|---|---|---|
| DINOv2 | 0.651 | 0.618 |
| Pan-FM | 0.670 | 0.638 |
| Improvement over DINOv2 | Drop-1 | Drop-2 | Drop-3 |
|---|---|---|---|
| AUROC | +0.030 | +0.026 | +0.030 |
| BalAcc | +0.021 | +0.017 | +0.018 |
These results are evaluated on a held-out test set of 2,100 subjects, comprising 1,300 disease cases and 800 controls. Only 17 subjects (0.8%) have all seven modalities. The Drop- settings further remove modalities on top of this natural missingness. This evaluation is therefore substantially more challenging than the current setting in the paper, where 33% of participants have complete seven-organ data. The heavier missingness likely contributes to the lower absolute performance. Nevertheless, Pan-FM maintains a consistent advantage over DINOv2 across all evaluated settings.
Overall, these results show that SGM is not specific to imaging-derived features and remains effective across heterogeneous raw imaging modalities, including MRI, DXA, and retinal OCT. The raw-imaging extension also broadens the practical applicability of Pan-FM to downstream datasets that provide raw scans but do not share an identical pre-extracted feature pipeline. We will include these new results in the revised paper.
W3: Whether attention is stable, and whether it reflects biologically meaningful organ contributions.
Appendix Fig. 15 evaluates the stability of the learned organ saliency throughout pre-training. The saliency trajectories evolve progressively rather than changing abruptly, and Pan-FM with SGM exhibits smoother trajectories and smaller fluctuations than DINOv2. This suggests that SGM promotes a more stable allocation of attention across organs.
Appendix Fig. 16 assesses biological relevance through leave-one-organ-out disease prediction. Removing different organs causes disease-specific performance drops. Adipose contributes broadly across several disease groups, whereas brain removal most strongly affects mental and behavioural disorders. These patterns suggest that the attention-derived representation captures biologically meaningful, disease-dependent organ contributions.
Questions
Q1: An ablation on CAPE is missing. Would not balancing the organ dimensions affect the results?
We thank the reviewer for this important suggestion. The original organ dimensions are highly imbalanced: Brain and Heart contribute 87.3% of all 228 IDPs, with a largest-to-smallest ratio of 39.7:1. CAPE maps the seven organs from IDPs to tokens, reducing this ratio to 16:1 and the combined Brain&Heart share to 75.0%.
We therefore compare DINOv2 and Pan-FM with either feature-wise tokenization or CAPE, while keeping all other settings fixed.
| Tokenization | DINOv2 | Pan-FM |
|---|---|---|
| Original IDP feature-wise tokens | 64.1 | 66.6 |
| CAPE organ tokens | 65.2 | 67.2 |
CAPE improves AUROC by 1.1 points for DINOv2 and 0.6 points for Pan-FM, supporting its effectiveness in reducing organ-dimensional imbalance. Pan-FM also outperforms DINOv2 under both tokenization schemes. Note that the SGM gain is larger under the more imbalanced feature-wise setting, at 2.5 points compared with 2.0 points using CAPE, suggesting that SGM is helpful when organ imbalance is more severe. Overall, CAPE and SGM provide complementary benefits.
Q2 and Q4: Some organs have minor effect. Can a small subset of dominant organs match all seven? Why can removing two organs occasionally outperform removing one?
Thank you for this careful observation. The small average effect of removing organs such as the pancreas in Fig. 4 partly results from averaging over all 13 disease categories. Appendix Fig. 16 provides a leave-one-organ-out analysis showing that organ contributions are disease-specific. For example, removing the pancreas reduces AUROC for mental and behavioural disorders by 0.011 and 0.014 under LP and FT, respectively. Its smaller overall contribution is also expected given that it is represented by only four tokens, compared with 64 for brain, 32 for heart, and 16 for adipose.
| Removed organ | Disease Group | LP | FT |
|---|---|---|---|
| Brain | Mental & behavioural | 0.051 | 0.048 |
| Liver | Infectious & parasitic | 0.025 | 0.017 |
| Heart | Eye | 0.019 | 0.024 |
| Spleen | Infectious & parasitic | 0.004 | 0.015 |
| Kidney | Blood & immune | 0.014 | 0.008 |
| Pancreas | Mental & behavioural | 0.011 | 0.014 |
Tables 10 and 12 show that Pan-FM AUROC decreases progressively from all seven organs to removing one, two, and three organs. Likewise, Figs. 7 and 8 show that removing any individual organ lowers the mean balanced accuracy under both LP and FT. Thus, even organs with modest average effects provide complementary disease-specific information, and the complete seven-organ input achieves the strongest overall performance.
Q3: Reporting the relative improvement over DINOv2 is unusual.
Thank you for this suggestion. Reviewer h3iE raised the same concern (h3iE-W2) for the full discussion. In the revised version, we will additionally report the absolute improvement in the revision.
Q5: The paper lacks comparisons with recent methods (2024 to 2026) and with medical imaging FMs.
Thank you for this suggestion. Most existing medical imaging FMs are trained for a single organ or modality, whereas Pan-FM targets joint subject-level multi-organ learning under missingness, making a direct comparison in the current feature-based setting difficult. We therefore use controlled comparisons with six SSL methods under the same backbone, tokenizer, and training data, together with 35 single-organ baselines shown in Tables 16 and 17. In addition, our new raw-imaging Pan-FM can be transferred to downstream single-organ imaging datasets, enabling more direct comparisons with existing organ-specific imaging medical FMs. We will expand the discussion in the revision.
Official Comment by Authors
Dear Reviewer EkFC,
As the author-reviewer discussion period is coming to a close, we’d be happy to clarify any remaining concerns.
Thank you again for your time and valuable feedback.
Best, The author(s)
Dear Author, Thank you for your active discussion.
Dear Reviewer EkFC, please let the authors know of any comments or concerns following their rebuttal.
I appreciate the efforts made to improve the paper. However, my major concerns still partly remain. Adding one external application is helpful, but ideally various organs from a large number of different centers should be tested. Regarding the attention stability and biological implication, it would be more helpful to have direct quantitative measures that evaluate the two aspects. Therefore, my rating remains 4, which is positive.
- Rating
- 5/6
- Confidence
- 5/5
- Quality
- 3/4
- Clarity
- 4/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The authors propose Pan-FM, a multi-organ foundation model, pre-trained on imaging from seven organs. Pan-FM treats each organ’s MRI features as semantic token patches and integrates them into the backbone. The proposed model uses Saliency-Guided Masking (SGM), which leverages the model's attention distribution to adaptively mask dominant organs during pre-training, and jointly learns cross-organ representations from subject-level multi-organ data. The UK Biobank MRI dataset for seven organs was used as the pre-training dataset. Pan-FM adapts DINOv2-style self-distillation for multi-organ representation learning, where the teacher model receives the full set of available organs for each participant, while the student model receives an additional masked view produced by random organ masking. Pan-FM's cross-modal pretraining protocol can be integrated with baseline SSL pretraining techniques, and the model has been evaluated on a few downstream tasks, outperforming the baselines.
Strengths and weaknesses
Weaknesses:
- The paper lacks qualitative results and visualizations illustrating how SGM guides the adaptive masking of tokens. Providing saliency maps and the resulting masks on sample images can help readers better understand the model's behavior.
- The model has been validated on the UK Biobank dataset. I am wondering if the foundation model can be generalized to external datasets using only one organ.
Strengths:
- The problem statement is well-defined and clearly motivated, including the dominant-organ shortcut learning bias statement.
- The idea of integrating MRI-derived imaging features of the organ to encode modality availability and cross-modal representation learning is interesting and insightful.
Overall, the paper is strong and introduces interesting ideas for building medical foundation models.
Questions
-
Could the authors please clarify whether the downstream task training datasets were resampled from the pretraining dataset (as mentioned in lines 584–586)? If there is subject overlap between pretraining and fine-tuning, this could lead to data leakage and positive performance estimates.
-
Based on Table 8 representing the low-level MRI-derived features, could the Pan-FM be used for the downstream tasks trained on external datasets (e.g., ADNI dataset for Alzheimer's disease prediction), as only one disease is to be predicted without having other organs?
-
As discussed in the weaknesses, could the authors provide visualizations of the saliency maps and illustrate how the adaptive token masking is applied?
Limitations
Yes
Formatting concerns
None
3 comments
Rebuttal
We thank the reviewer for their positive and constructive feedback, and for recognizing our problem formulation, the dominant-organ shortcut learning bias analysis, and the idea of encoding modality availability for cross-modal representation learning. We agree that an external single-organ evaluation and a clearer qualitative visualization would strengthen the paper, and we address both below.
Before delving into the reviewer's insightful questions, we would first like to highlight some additional results:
Additional Results
External evaluation on ADNI (single-organ transfer). We evaluate our UK Biobank pre-trained Pan-FM on ADNI for Alzheimer's disease versus cognitively normal classification, using brain features only. ADNI differs from UK Biobank in country, scanner fleet, acquisition protocol, and recruitment, and it is disease-enriched rather than a general population cohort. Because ADNI provides only brain imaging, 6 of the 7 organs are absent for our Pan-FM, which is substantially more challenging than the standard organ-drop setting in Table 2.
No architectural change is required. Pan-FM naturally handles the single-organ input with the masking mechanism. As defined in Sec. 3.1 and Eq. (2), available organs are represented by their CAPE-encoded feature tokens, whereas unavailable organs are represented by their learned mask tokens together with the corresponding organ embeddings. For ADNI, we simply set the availability vector to , the six missing organs use their mask tokens, and the backbone and CAPE stay the same as in pre-training. So the brain-only AD classification on ADNI is handled as a standard missing-organ configuration rather than as a special architectural case. For the brain input we use the same 119 MUSE gray matter volumes as in pre-training (Appendix Table 8).
Details. Following [1], we define the AD and CN groups in ADNI based on the diagnosis at the baseline visit and require the diagnosis to remain stable throughout follow-up. This yields 1,076 subjects, including 688 CN and 388 AD, from the 2,515 participants with available imaging. We randomly select 100 AD and 100 CN subjects to construct a class-balanced independent held-out test set. The remaining 876 subjects form the development set, on which we perform 5-fold cross-validation. For each fold, the model is trained on four folds and validated on the remaining fold, resulting in five independently trained models. Each model is then evaluated on the same held-out test set, and we report the mean and standard deviation across the five models. All splits are performed at the subject level, and the held-out test subjects are strictly excluded from model training and validation.
| Backbone | Method | Val BalAcc | Test BalAcc, 5 folds | Test BalAcc mean ± std |
|---|---|---|---|---|
| MLP | Raw MUSE features | 0.870 ± 0.015 | 0.890, 0.865, 0.895, 0.915, 0.905 | 0.894 ± 0.017 |
| SVM | Raw MUSE features | 0.879 ± 0.023 | 0.900, 0.885, 0.920, 0.905, 0.905 | 0.903 ± 0.011 |
| ViT | Fine-tuning from scratch | 0.885 ± 0.011 | 0.870, 0.870, 0.875, 0.850, 0.860 | 0.865 ± 0.009 |
| ViT | DINOv2 pre-trained on UKBB | 0.893 ± 0.024 | 0.890, 0.890, 0.890, 0.920, 0.890 | 0.896 ± 0.012 |
| ViT | Pan-FM pre-trained on UKBB | 0.905 ± 0.011 | 0.910, 0.930, 0.915, 0.925, 0.925 | 0.921 ± 0.007 |
Results. Pan-FM transfers effectively to ADNI despite the domain shift and the absence of six organs. Using brain features alone, it achieves 0.921 ± 0.007 test balanced accuracy, outperforming DINOv2 (0.896 ± 0.012), training from scratch (0.865 ± 0.009), and classical baselines. For a fair comparison, we perform the same learning-rate grid search for all deep models and select hyperparameters using validation performance only. We also fix the random seeds for data splitting, model initialization, and training to ensure reproducibility. These results demonstrate effective single-organ transfer on ADNI without architectural modification and improved robustness under extreme organ missingness.
Weaknesses and Questions
W1 and Q3: The paper lacks qualitative visualization of the saliency and of how the adaptive token masking is applied.
We thank the reviewer for this suggestion, and we would like to point to Appendix Fig. 15 (Sec. E.3), which visualizes the SGM behaviour and which we will promote to the main paper. Specifically, Fig. 15 plots the per-organ saliency distribution, defined as the CLS attention mass the teacher assigns to each organ's tokens on the full multi-organ input, following Eq. (5). Fig. 15(a) and 15(b) trace this distribution across all 200 pre-training epochs for the DINOv2 baseline and for Pan-FM respectively, and Fig. 15(c) compares initialization against the final state of both models. The two runs share the same initialization, schedule and data, differing only in the masking strategy, so the figure isolates the effect of SGM.
The visualization makes the SGM mechanism directly visible. At initialization, saliency simply tracks token count: brain holds 48%, adipose 13%, and the four small organs 13% in total. After pre-training, the DINOv2 baseline reduces brain to 15% but shifts the dominance to adipose (36%). Under SGM, adipose is held to 32% and the four small organs rise to 27%, despite accounting for only 14% of all tokens. This demonstrates that our SGM redistributes representation capacity across organs instead of merely shifting dominance to another organ, thus improving robustness to missing organs, as shown in Tables 2 and 10.
We further agree that the appendix currently shows only the organ saliency scores of Eq. (5), which drive the masking, and not the masking distribution itself. In the camera-ready version we will additionally visualize the masking probabilities obtained from Eq. (6) by applying the softmax function and how they evolve over training, so that both stages of the pipeline, what the model attends to and what it consequently masks, are visible to the readers.
W2 and Q2: Validation is confined to UK Biobank, and it is unclear whether the model generalizes to external datasets such as ADNI using only one organ.
We thank the reviewer for raising this important concern. Please refer to the External evaluation on ADNI (single-organ transfer) in the Additional Results section above. This experiment evaluates cross-cohort generalization using brain features alone, with the other six organs absent. Pan-FM pre-trained on UKBB transfers effectively to ADNI without any architectural modification, supporting both external generalization and robustness under the most extreme single-organ setting considered in this work.
Q1: Were the downstream training datasets resampled from the pre-training dataset (lines 584–586), and could this cause data leakage?
Thank you for raising this question. As described in Appendix A.2 (lines 576–582), we first construct a held-out test set of 1,280 subjects, comprising 500 cognitively normal (CN) and 780 disease-positive participants. These subjects are strictly excluded from both self-supervised pre-training and downstream supervised training. Appendix Table 6 reports the composition of this split, and all group-disease results are evaluated exclusively on this unseen test set.
Lines 584–586 describe how the downstream training set is obtained from the remaining pre-training pool: among the 40,689 subjects used for label-free pre-training, we retain the 36,220 subjects with confirmed CN or disease-positive labels for supervised downstream training. This follows the standard self-supervised learning protocol, in which a model is first pre-trained without labels on a large unlabeled cohort and is subsequently evaluated by training a supervised predictor on a labeled subset of that cohort. Importantly, no disease or CN labels are used during pre-training, and no held-out test subject is observed at any stage of model development. Therefore, there is neither test-set leakage nor label leakage during pre-training. All SSL baselines follow the identical data split and evaluation protocol (Appendix C.1), ensuring a fair comparison. We will add a clearer split diagram to the main paper to make this protocol explicit.
References
[1] Wen et al., Convolutional neural networks for classification of Alzheimer's disease: Overview and reproducible evaluation. Medical Image Analysis, 63:101694.
Response to Authors' rebuttal
Thank you for the detailed and thoughtful rebuttal. The additional explanations and experiments substantially address my main concerns.
The external ADNI evaluation is particularly valuable. The brain-only setting, in which the other six organs are unavailable, provides a meaningful test of both cross-cohort transfer and robustness under extreme organ missingness. The reported improvement of Pan-FM over DINOv2, training from scratch, and the classical baselines supports the claim that the learned representation can be used on an external dataset without requiring all seven organs or modifying the architecture. I strongly encourage the authors to include this experiment, along with the complete preprocessing, normalization, splitting, and hyperparameter-selection details, in the revised paper.
The clarification of the UK Biobank data split also resolves my concern regarding potential leakage, and the proposed saliency and masking visualizations should improve interpretability.
The response has addressed my main concerns. I have no further questions and maintain my positive assessment and current rating.
Official Comment by Authors
We sincerely thank the reviewer for the insightful comments and for engaging with our rebuttal. We are very pleased to hear that the additional ADNI evaluation and the clarification of the UK Biobank data split have addressed the reviewer’s main concerns. We will include this experiment in the revised manuscript, together with complete preprocessing, normalization, data-splitting, and hyperparameter-selection details.
Once again, we thank the reviewer for strengthening our paper with their valuable insights. We remain actively available to address any further questions or clarifications.
- Rating
- 5/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 4/4
- Significance
- 3/4
- Originality
- 4/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The authors present Pan-FM: the first multi-organ foundation model that jointly models 7 cross-organ interactions and handles missing organ problems. The authors design a unified backbone that supports cross-organ missingness at both train and test time, and pre-train via masking-based self-distillation, introducing Saliency-Guided Masking (SGM) that selects organs to mask based on the model’s attention distribution to address the problem of dominant-organ shortcut learning bias. While introducing negligible computational overhead, the authors demonstrate that the SGM approach utilized for Pan-FM allows the model to achieve stronger prediction across 13 disease categories and 14 single disease entities on the UK Biobank dataset when compared with other single-organ and multi-organ foundation model baselines.
Strengths and weaknesses
Strengths:
- The research is well motivated: multi-organ data ought to be jointly modeled, and organ data may often not be missing at random in clinical settings. The authors further establish their approach in relation to Single-Organ FMs or Independent Multi-Organ FMs, neither of which jointly model cross-organ interactions. The authors argue this as important given the multi-organ nature of several diseases and other biological processes.
- The Cross-Attention based Tabular Patch Encoding (CAPE) and the Saliency-Guided Masking are carefully designed and very clearly presented. The mathematical definitions and derivations are clear and easy to follow, and also seem appropriate given the context.
- Another major strength of the paper is the thorough set of evaluations. They standardize the backbone and pre-training settings across all baselines (Pan-FM included) for accurate comparisons. The reviewer appreciates the rigor adopted to perform method specific hyper-parameter tuning while maintaining comparability across SSL baselines and Pan-FM. Building on this set up, the authors present detailed results for linear probing and full fine-tuning on Group-disease evaluation, Missing-organ robustness, and Single-organ dropout, with a variety of additional results included in the Appendix.
- The authors conduct ablations for most meaningful parameters such as mask ratio, temperature (which controls the sharpness of the organ-sampling distribution) to select the parameters appropriately.
- The authors also establish the minimal computational overhead posed by SGM, both theoretically and empirically, with additional results reported in the Appendix.
Weaknesses: The reviewer finds it hard to identify many weaknesses and commends the authors for their technically strong and rigorous research. A few points:
- Throughput the paper, results wherever presented mostly lack the inclusion of Confidence Intervals. There also does not seem to be discussion for why such an exclusion is appropriate and thus remains a key weakness. The inclusion of confidence intervals may highlight the absence of statistically significant difference in the performance metrics observed using Pan-FM relative to the baselines.
- For certain reported results, the delta % relative to DINOv2 seems less appropriate in cases where DINOv2 was not the next best performing baseline. For example, in Table 2, MoCo-v3 seems to be the next best performing model for Standard LP and Drop 3 Organs LP/FT.
Questions
Questions:
- Could the authors clarify whether the organ tokens are arranged in a pre-determined order? It seems from the figures that Brain is always in the first position and Liver is always in the last position. If so, what is the technical interpretation of p_{o}?
- Did the authors consider external evaluations on disease prediction tasks from other datasets? This would help establish the generalizability and potential for downstream adaptation of Pan-FM further, and would stimulate improvement in the rating provided to the paper.
Limitations
The authors are transparent about the key limitations of their research. They mention the inherent biases which may exist in the UK Biobank dataset which is comprised of predominantly white-British and middle-aged-to-elderly individuals. The authors also cede to the limitations of using low-dimensional pre-extracted MRI-derived imaging phenotypes instead of raw voxel data, and identify that as an area for future work.
Final justification
The reviewer would like to maintain the score of 5 while emphasizing acceptance. At the same time, the reviewer also appreciates and acknowledges the efforts of the authors during the rebuttal phase to strengthen their research.
Formatting concerns
N/A
3 comments
Rebuttal
We thank the reviewer for their insightful feedback, and for recognizing the motivation, clear formulation of CAPE and SGM, rigorous experimental design, comprehensive evaluations, and minimal computational overhead. These comments have helped us improve the paper’s clarity, and we address each concern below.
Weaknesses
W1: Results are reported without confidence intervals, which may hide the absence of a significant difference.
Thanks for the question. We measure variability and report it in the appendix, where Tables 14 and 15 (Sec. D.5) and Table 19 (Sec. E.4) give mean and standard deviation. As described in Appendix C.3, results in the main tables are already the average over 10-runs, and we report the corresponding standard deviations for the Standard setting below.
| Metric | Pan-FM | DINOv2 | MoCo-v3 | SimCLR | Barlow T. | VICReg | BYOL |
|---|---|---|---|---|---|---|---|
| AUROC | 0.672±0.002 | 0.652±0.001 | 0.658±0.001 | 0.654±0.001 | 0.646±0.002 | 0.641±0.002 | 0.636±0.001 |
| BalAcc | 0.638±0.001 | 0.623±0.002 | 0.625±0.002 | 0.622±0.001 | 0.615±0.002 | 0.612±0.002 | 0.606±0.001 |
Following the reviewer's suggestion, we have also quantified the improvement, treating the 13 disease categories as the unit of comparison. Cells give the mean AUROC in favour of Pan-FM with its 95% CI across the 13 categories, so an interval excluding zero indicates a significant improvement.
| Setting | DINOv2 (Our Baseline) | MoCo-v3 | SimCLR | Barlow T. | VICReg | BYOL |
|---|---|---|---|---|---|---|
| Standard | +.021 [.013,.028] | +.015 [.004,.025] | +.019 [.010,.028] | +.027 [.016,.038] | +.032 [.023,.041] | +.036 [.027,.045] |
| Drop 1 Organ | +.027 [.009,.045] | +.028 [.014,.042] | +.036 [.024,.048] | +.049 [.028,.069] | +.041 [.021,.062] | +.039 [.022,.057] |
| Drop 2 Organs | +.025 [.011,.039] | +.018 [.007,.028] | +.034 [.023,.045] | +.040 [.024,.056] | +.033 [.018,.049] | +.027 [.013,.042] |
| Drop 3 Organs | +.037 [.020,.054] | +.012 [-.001,.026] | +.029 [.016,.042] | +.036 [.020,.053] | +.030 [.013,.047] | +.025 [.009,.042] |
23 of these 24 comparisons are significant, i.e. the interval excludes zero in every case but one. The single exception is Pan-FM versus MoCo-v3 under Drop 3 Organs, where Pan-FM is better in 9 of 13 categories and the interval only just includes zero. Note that MoCo-v3 uses a momentum-based contrastive objective and explicitly uses negatives for more discriminative learning than our baseline DINOv2, which is why the margin narrows in this particular setting.
We emphasize that Pan-FM is built directly on DINOv2, making DINOv2 the controlled ablation that isolates the contribution of SGM. Pan-FM significantly outperforms DINOv2 in every setting, with all confidence intervals excluding zero and the performance margin increasing as more organs are removed. SGM is also not specific to DINOv2. Table 4 and Appendix Table 13 show consistent gains when SGM is integrated into SimCLR, VICReg, and Barlow Twins.
W2: The reported % is computed against DINOv2 even when MoCo-v3 is the second-best method.
Thanks for pointing out this and we will change how we present it. Our reason for choosing DINOv2 was not that it is the strongest baseline, but that Pan-FM is built upon DINOv2 with SGM. As described in Appendix C.1, all methods share the same ViT backbone, the same CAPE tokenizer and the same training schedule, and Sec. 3.3 (Eq. 7) shows that Pan-FM and DINOv2 also share the same masking budget. The only difference is which organs are selected for masking during pretraining. The comparison against DINOv2 therefore measures the effect of SGM alone, which is the claim of the paper, and was not intended as a comparison against the best competitor. In the camera-ready revision, we will also report the performance gain over the second-best method in each column in Table 2 to avoid confusion.
Questions
Q1: Are the organ tokens arranged in a pre-determined order, and what is the technical interpretation of ?
Thanks for the question. The organs are concatenated in a default order (Brain, Heart, Adipose, Liver, Kidney, Spleen, Pancreas), as shown in Fig. 2. is a learnable token-identity embedding analogous to the positional embedding used in a standard ViT. However, because our tokens do not correspond to spatial image patches, “position” here denotes the token's semantic identity, i.e., which organ it belongs to and which of that organ's CAPE query slots it represents.
We use to break the permutation symmetry of self-attention. Without , the backbone would process the input as an unordered set and could not distinguish, for example, a heart token from a liver token. Importantly, is added whether organ is observed or missing, so the model always retains the identity of the absent organ and can treat missingness as structured input. We will clarify these points in Sec. 3.1. After constructing in Eq. (2), all organ tokens are jointly processed by global self-attention. Reordering the organ token groups together with their corresponding therefore leaves the global representation unchanged. Therefore, the organ order shown in Fig. 2 is only an indexing convention rather than a modeling constraint.
Q2: Did the authors consider external evaluation on disease prediction tasks from other datasets?
We thank the reviewer for raising this important concern.
External evaluation on ADNI (single-organ transfer). We evaluate our UK Biobank pre-trained Pan-FM on ADNI for Alzheimer's disease versus cognitively normal classification, using brain features only. ADNI differs from UK Biobank in country, scanner fleet, acquisition protocol, and recruitment, and it is disease-enriched rather than a general population cohort. Because ADNI provides only brain imaging, 6 of the 7 organs are absent for our Pan-FM, which is substantially more challenging than the standard organ-drop setting in Table 2.
No architectural change is required. Pan-FM naturally handles the single-organ input with the masking mechanism. As defined in Sec. 3.1 and Eq. (2), available organs are represented by their CAPE-encoded feature tokens, whereas unavailable organs are represented by their learned mask tokens together with the corresponding organ embeddings. For ADNI, we simply set the availability vector to , the six missing organs use their mask tokens, and the backbone and CAPE stay the same as in pre-training. So the brain-only AD classification on ADNI is handled as a standard missing-organ configuration rather than as a special architectural case. For the brain input we use the same 119 MUSE gray matter volumes as in pre-training (Appendix Table 8).
Details. Following [1], we define the AD and CN groups in ADNI based on the diagnosis at the baseline visit and require the diagnosis to remain stable throughout follow-up. This yields 1,076 subjects, including 688 CN and 388 AD, from the 2,515 participants with available imaging. We randomly select 100 AD and 100 CN subjects to construct a class-balanced independent held-out test set. The remaining 876 subjects form the development set, on which we perform 5-fold cross-validation. For each fold, the model is trained on four folds and validated on the remaining fold, resulting in five independently trained models. Each model is then evaluated on the same held-out test set, and we report the mean and standard deviation across the five models. All splits are performed at the subject level, and the held-out test subjects are strictly excluded from model training and validation.
| Backbone | Method | Val BalAcc | Test BalAcc, 5 folds | Test BalAcc mean ± std |
|---|---|---|---|---|
| MLP | Raw MUSE features | 0.870 ± 0.015 | 0.890, 0.865, 0.895, 0.915, 0.905 | 0.894 ± 0.017 |
| SVM | Raw MUSE features | 0.879 ± 0.023 | 0.900, 0.885, 0.920, 0.905, 0.905 | 0.903 ± 0.011 |
| ViT | Fine-tuning from scratch | 0.885 ± 0.011 | 0.870, 0.870, 0.875, 0.850, 0.860 | 0.865 ± 0.009 |
| ViT | DINOv2 pre-trained on UKBB | 0.893 ± 0.024 | 0.890, 0.890, 0.890, 0.920, 0.890 | 0.896 ± 0.012 |
| ViT | Pan-FM pre-trained on UKBB | 0.905 ± 0.011 | 0.910, 0.930, 0.915, 0.925, 0.925 | 0.921 ± 0.007 |
Results. Pan-FM transfers effectively to ADNI despite the domain shift and the absence of six organs. Using brain features alone, it achieves 0.921 ± 0.007 test balanced accuracy, outperforming DINOv2 (0.896 ± 0.012), training from scratch (0.865 ± 0.009), and classical baselines. For a fair comparison, we perform the same learning-rate grid search for all deep models and select hyperparameters using validation performance only. We also fix the random seeds for data splitting, model initialization, and training to ensure reproducibility. These results demonstrate effective single-organ transfer on ADNI without architectural modification and improved robustness under extreme organ missingness.
References
[1] Wen et al., Convolutional neural networks for classification of Alzheimer's disease: Overview and reproducible evaluation. Medical Image Analysis, 63:101694.
Reviewer Response to Rebuttal
The reviewer appreciates the clarifications and responses to the mentioned weaknesses. The reviewer also hopes that in providing the clarifications and addressing the weaknesses, the authors deem their research to have been strengthened.
Further, the reviewer greatly appreciates the effort from the authors to perform the external validation on the ADNI dataset, which is a significant enhancement to the paper. Given the efforts from the authors, the reviewer would like to maintain the score while emphasizing acceptance.
Official Comment by Authors
We sincerely thank the reviewer for the encouraging feedback and strong support. We are pleased that our clarifications and additional efforts have strengthened the work, and we greatly appreciate the reviewer’s recognition of the ADNI external validation as a significant enhancement.
Thank you again for your valuable feedback.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Response to the Area Chair W9SP
We thank the AC for the thoughtful summary and for identifying the key concerns shared across the reviews. We have addressed these concerns through new external and raw-imaging experiments, statistical analyses, additional ablations, and clearer explanations of SGM. We summarize the main additions below and provide references to the corresponding reviewer responses for full details.
External generalization across cohorts and imaging settings. We added an external evaluation on ADNI, which differs substantially from UK Biobank in population, scanner fleet, acquisition protocol, recruitment strategy, and disease prevalence. We transfer the UKBB-pretrained Pan-FM to Alzheimer's disease versus cognitively normal classification using brain features only. This represents an extreme missing-organ setting in which six of the seven pre-training organs are absent. Without any architectural modification, Pan-FM achieves 0.921 ± 0.007 test balanced accuracy, outperforming DINOv2 pre-training (0.896 ± 0.012), training the same ViT from scratch (0.865 ± 0.009), and classical MLP and SVM baselines. These results support both cross-cohort transfer and robustness when only a single organ is available. Please see EkFC-W1, USq3-W2/Q2, and h3iE-Q2 for the full experimental design, implementation details, and results.
Statistical uncertainty and significance. We now compute 95% confidence intervals across the 13 disease categories. Pan-FM significantly outperforms its direct DINOv2 baseline in every organ-missingness setting, with all confidence intervals excluding zero. Across all six SSL baselines and four evaluation settings, 23 of 24 comparisons have confidence intervals excluding zero. These analyses demonstrate that the reported improvements are generally consistent and are not explained by run-to-run variation. Please see h3iE-W1.
SGM evaluation, stability, and interpretability. We clarify that DINOv2 is the direct controlled ablation of SGM because Pan-FM retains the same backbone, CAPE tokenizer, masking budget, training data, and optimization schedule, while changing only the organ-selection strategy during masking. Appendix Fig. 15 visualizes the learned organ saliency throughout pre-training. The saliency evolves progressively, and Pan-FM with SGM exhibits smoother trajectories and smaller fluctuations than DINOv2, indicating a more stable allocation of attention across organs. Appendix Fig. 16 further evaluates predictive relevance through leave-one-organ-out disease prediction. The resulting performance drops are disease-specific, with adipose contributing broadly across several disease groups and brain removal having a particularly strong effect on mental and behavioural disorders. We will promote these analyses to the main paper and additionally visualize the masking probabilities derived from the saliency scores. Please see EkFC-W3 and USq3-W1/Q3.
Extension beyond low-dimensional imaging-derived features. To address the concern that pre-extracted features may omit information relevant to downstream tasks, we developed a raw-imaging Pan-FM using seven UK Biobank imaging modalities, including brain, cardiac, liver, and pancreas MRI, total-body DXA, and bilateral retinal OCT. The raw-imaging cohort contains 137,716 subjects, more than three times the cohort used in the current feature-based study, and has substantially more severe natural missingness, with only 1.0% of subjects having all seven modalities. Pan-FM achieves 0.670 AUROC and 0.638 balanced accuracy, compared with 0.651 and 0.618 for DINOv2, and maintains consistent gains under Drop-1, Drop-2, and Drop-3 settings. These results show that SGM is not specific to pre-extracted IDPs and remains effective across heterogeneous raw imaging modalities. Please see EkFC-W2.
CAPE ablation and stronger baseline analysis. We added the requested CAPE ablation by comparing feature-wise tokenization with CAPE while keeping all other settings fixed. CAPE improves DINOv2 from 64.1 to 65.2 AUROC and Pan-FM from 66.6 to 67.2, supporting its effectiveness in reducing organ-dimensional imbalance. Pan-FM remains superior to DINOv2 under both tokenization schemes, showing that SGM provides additional gains beyond those achieved by CAPE. We also clarify the comparison with 6 SSL methods, report gains over the second-best baseline. Please see EkFC-Q1/Q5 and h3iE-W2.
Overall, we believe these additional analyses help address the concerns regarding external generalization, statistical uncertainty, SGM evaluation and interpretability, representational scope, CAPE ablation, and baseline coverage. We will incorporate the new results into the revised manuscript and move the most relevant appendix analyses to the main text for clearer presentation. We would also be grateful to address any further concerns from the reviewers or the AC during the discussion period.