Beyond ViT Tokens: Masked-Diffusion Pretrained Convolutional Pathology Foundation Model for Cell-Level Dense Prediction
Weiming Chen, Xitong Ling, Zhenyang Cai, Xidong Wang, Jiawen Li, Tian Guan, Benyou Wang, Yonghong He
NeurIPS 2026
TL;DR. We introduce CMD, a masked-diffusion pretrained convolutional pathology foundation model that outperforms prevailing ViT-based counterparts on cell-level dense prediction tasks in computational pathology.
Abstract. Cell-level dense prediction is central to computational pathology, but remains challenging due to fine-grained histological structures, strong domain shifts, and costly dense annotations. Existing ViT-based pathology foundation models rely on patch tokenization, which can disrupt spatial continuity and weaken local morphological details needed for cell-level prediction. To address this, we pro pose Masked-Diffusion Convolutional Foundation Models, termed ConvNeXt Masked-Diffusion (CMD), a self-supervised convolutional generative pretrain ing framework for dense pathology representation learning. CMD uses a fully convolutional ConvNeXt-UNet backbone, performs masked-diffusion pretrain ing in pixel space, and incorporates frozen pathology foundation model features through adaptive normalization. Experimental results demonstrate that CMD consistently outperforms existing ViT-based pathology foundation models and even surpasses state-of-the-art end-to-end segmentation methods while fine-tuning only a small number of task-specific parameters across multiple pathology dense prediction tasks. The advantage is particularly pronounced under limited an notation settings, where CMD exhibits stronger robustness and generalization ability. Our findings suggest that purely convolutional architectures can also serve as competitive pathology foundation models for cell-level dense prediction, achieving leading performance within the current ViT-dominated paradigm and providing a scalable, high-performance solution that better preserves histological structural priors for fine-grained pathology understanding. Code is available at https://github.com/M4A1TasteGood/ConvNeXt-Masked-Diffusion
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:49 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
The authors propose a novel framework for cell-level dense prediction that alleviate the current limitations of ViTs that disrupt the spatial continuity through the patch tokenization. They introduce ConvNext Masked-Diffusion, a self-supervised technique that leverages masked diffusion, coupled with pathology foundation model feature conditioning as a complementary semantic guidance through adaLN conditioning.
Reviewers raised a number of questions on the reasons for the claimed performance improvement. A number of evaluation and experiments are requested by Rev m7zr and 21kp
Final justification
The authors have proven experimentally that the performance improvement comes from the paper's methodological contributions. Reviewwers were satisfied with the additional experiments. As such the paper should be accepted.
Read meta-review
Meta-review
The authors propose a novel framework for cell-level dense prediction that alleviate the current limitations of ViTs that disrupt the spatial continuity through the patch tokenization. They introduce ConvNext Masked-Diffusion, a self-supervised technique that leverages masked diffusion, coupled with pathology foundation model feature conditioning as a complementary semantic guidance through adaLN conditioning.
Reviewers raised a number of questions on the reasons for the claimed performance improvement. A number of evaluation and experiments are requested by Rev m7zr and 21kp
Final justification
The authors have proven experimentally that the performance improvement comes from the paper's methodological contributions. Reviewwers were satisfied with the additional experiments. As such the paper should be accepted.
1 comment
- Rating
- 5/6
- Confidence
- 5/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The study introduces CMD, a convolutional-based pathology foundation model for cell-level dense prediction. Its key contribution lies in its two-component design: 1) a pixel-space masked-diffusion pretraining strategy built on a ConvNeXt-UNet backbone to preserve local morphology and boundary details, and 2) the use of frozen pathology foundation model conditioning together with lightweight segmentation heads for efficient downstream adaptation. Experiments on the three benchmarks, CPM15, CPM17, and TNBC, demonstrate the effectiveness of the proposed method.
Strengths and weaknesses
The paper proposes CMD, a convolutional pathology foundation model for cell-level dense prediction. A clear strength is that the method is well aligned with cell-level dense prediction: the ConvNeXt-UNet backbone, pixel-space masked-diffusion pretraining, and frozen dense feature extraction are designed to preserve local morphology, nuclear boundaries, and spatial continuity. The empirical results are also strong. On CPM15, CPM17, and TNBC, CMD achieves better performance than many ViT-based pathology foundation models, suggesting that convolutional masked-diffusion pretraining can learn more suitable dense representations for fine-grained pathology tasks. The paper further includes useful ablations on backbone choice, pretraining space, pathology foundation model conditioning, pretraining duration, and model capacity, which makes the design choices more convincing.
The main weaknesses are as follows:
- The evaluation lacks results on larger and more diverse nuclei segmentation datasets such as PanNuke. Since PanNuke contains multiple tissue types and more heterogeneous annotations, including it would better demonstrate whether the learned representation generalizes beyond the current benchmarks.
- The paper does not compare CMD with a ConvNeXt backbone initialized from standard ImageNet-pretrained weights under the same downstream protocol. This comparison is important because it would help isolate the benefit of the proposed masked-diffusion pathology pretraining from the benefit of using a strong convolutional architecture.
- The paper does not provide sufficient details on how the ViT-based pathology foundation models are adapted for cell-level segmentation, such as which token features are used, how patch tokens are converted into dense feature maps, and whether the segmentation heads are architecturally matched to CMD. This makes the comparison with ViT-based baselines harder to fully assess.
Questions
- Could the authors provide results on a larger and more diverse dataset such as PanNuke to better demonstrate cross-tissue generalization?
- Could the authors compare CMD with an ImageNet-pretrained ConvNeXt backbone under the same frozen-backbone and segmentation-head setting?
- Could the authors clarify how ViT-based pathology foundation models are adapted for cell-level segmentation, including token selection, feature reshaping, and segmentation-head design?
Limitations
yes
Formatting concerns
No major formatting or anonymity concerns observed.
3 comments
Rebuttal
We sincerely appreciate your recognition of our work and your professional suggestions for improvement. In response to the three issues you raised, we have supplemented corresponding experiments and detailed explanations as follows:
A1: Supplementary experiments on the multi-tissue PanNuke dataset (Response to Q1 and W1)
Following your suggestion, we have supplemented the experimental results of CMD-L on the PanNuke dataset. PanNuke contains multiple human tissue types with more heterogeneous annotations, which can more fully verify the cross-tissue generalization ability of the model. The experimental results are presented below (metric format: Dice / Precision / Boundary F1):
| Method | PanNuke (Dice / Pre / BF1) |
|---|---|
| PathOrchestra | 0.580/0.692/0.611 |
| CONCHv1.5 | 0.601/0.707/0.632 |
| CONCH | 0.595/0.705/0.621 |
| Prov-Gigapath | 0.609/0.715/0.654 |
| Hibou | 0.610/0.725/0.711 |
| H-Optimus-0 | 0.620/0.732/0.700 |
| H-Optimus-1 | 0.619/0.731/0.691 |
| Kaiko | 0.619/0.727/0.691 |
| Midnight-12k | 0.575/0.670/0.547 |
| MUSK | 0.513/0.605/0.333 |
| Phikon | 0.597/0.691/0.647 |
| Phikon-v2 | 0.614/0.717/0.656 |
| UNI-v1 | 0.598/0.711/0.630 |
| UNI-v2 | 0.609/0.725/0.656 |
| Virchow | 0.608/0.720/0.660 |
| Virchow2 | 0.609/0.716/0.660 |
| CMD-L(Ours) | 0.711/0.712/0.705 |
The experimental results show that on large-scale, multi-tissue complex datasets such as PanNuke, CMD-L achieves even more significant performance advantages over existing ViT-based pathology foundation models. This further verifies that the dense feature representations learned by our convolutional masked-diffusion pretraining possess stronger cross-tissue generalization capability for fine-grained pathology segmentation tasks. We will add this part of results to the experimental section of the main text.
A2: Supplementary baseline of ImageNet-pretrained ConvNeXt backbone (Response to Q2 and W2)
Under exactly the same experimental setting (frozen backbone, identical segmentation head architecture and training protocol), we have supplemented the ConvNeXt backbone baseline initialized with standard ImageNet-pretrained weights. The experimental results are presented below (metric format: Dice / Precision / Boundary F1):
| Method | cpm15(Dice / Pre / BF1) | cpm17(Dice / Pre / BF1) | TNBC(Dice / Pre / BF1) |
|---|---|---|---|
| CMD-L(ImageNet-ConvNeXt) | 0.836/0.842/0.683 | 0.835/0.856/0.632 | 0.755/0.814/0.550 |
| CMD-L(ours) | 0.889/0.885/0.947 | 0.880/0.883/0.866 | 0.854/0.830/0.838 |
The comparison results clearly demonstrate that, with the same backbone architecture and downstream settings, our proposed pathology-domain masked-diffusion pretraining brings significant performance improvement compared with general ImageNet pretraining. This proves that the performance advantage of CMD mainly stems from the domain-adapted pretraining strategy, rather than the benefit of the ConvNeXt architecture itself.
A3: Clarification of segmentation adaptation details for ViT baseline models (Response to Q3 and W3)
We first supplement the complete downstream segmentation adaptation pipeline for all ViT-based pathology foundation models in the original manuscript:
- Token feature selection: We uniformly adopt the patch tokens output by the last Transformer layer of ViT, with the shape of , where denotes the total number of image patches and is the feature embedding dimension.
- Feature dimension reshaping: The sequential patch tokens are converted into a 2D dense feature map via deterministic reshape, with the shape of .
- Segmentation head design: We adopt a lightweight decoder structure, which first adjusts the feature channel number via 3×3 convolution, then restores the input resolution via stepwise bilinear upsampling, and finally produces pixel-level segmentation predictions.
Regarding the fairness of the segmentation head that you concerned about, we further supplement a controlled experiment with a unified multi-scale segmentation head: both CMD and all ViT baselines adopt a multi-scale segmentation head with exactly the same architecture, whose design is consistent with the right panel of Figure B2 in the appendix: we select outputs from Transformer layers corresponding to the hierarchical features of CMD-L downstream, align their resolutions via upsampling, perform feature concatenation, and then generate predictions after channel reduction via a lightweight 3×3 convolution. We re-conduct the comparison under the setting of frozen backbone and identical training protocol. The results are presented below (metric format: Dice / Precision / Boundary F1):
| Method | cpm15(Dice / Pre / BF1) | cpm17(Dice / Pre / BF1) | TNBC(Dice / Pre / BF1) |
|---|---|---|---|
| CMD-L(ours) | 0.889/0.885/0.947 | 0.880/0.883/0.866 | 0.854/0.830/0.838 |
| UNI-v1 | 0.725/0.715/0.435 | 0.834/0.817/0.501 | 0.792/0.748/0.378 |
| UNI-v2 | 0.758/0.734/0.502 | 0.847/0.842/0.554 | 0.809/0.776/0.450 |
| CONCH-v1 | 0.732/0.710/0.456 | 0.836/0.848/0.521 | 0.796/0.780/0.400 |
| CONCH-v1.5 | 0.729/0.713/0.458 | 0.843/0.827/0.522 | 0.802/0.785/0.439 |
| Virchow-v1 | 0.752/0.752/0.526 | 0.849/0.839/0.556 | 0.817/0.788/0.470 |
| Virchow-v2 | 0.759/0.740/0.513 | 0.848/0.838/0.567 | 0.815/0.779/0.467 |
| Phikon | 0.731/0.721/0.452 | 0.834/0.824/0.495 | 0.804/0.780/0.431 |
| Phikon-v2 | 0.726/0.719/0.436 | 0.835/0.822/0.504 | 0.794/0.769/0.400 |
| GigaPath | 0.731/0.715/0.440 | 0.838/0.831/0.515 | 0.802/0.773/0.427 |
| Hibou-L | 0.767/0.746/0.540 | 0.856/0.861/0.589 | 0.820/0.804/0.486 |
| H-Optimus-0 | 0.762/0.754/0.521 | 0.858/0.842/0.587 | 0.820/0.788/0.477 |
| H-Optimus-1 | 0.756/0.757/0.515 | 0.858/0.851/0.593 | 0.815/0.786/0.469 |
| Kaiko-ViT-L/14 | 0.768/0.760/0.533 | 0.855/0.851/0.587 | 0.814/0.791/0.460 |
| Midnight-12k | 0.742/0.731/0.473 | 0.842/0.825/0.533 | 0.804/0.770/0.428 |
| MUSK | 0.686/0.690/0.318 | 0.741/0.730/0.371 | 0.713/0.690/0.289 |
| PathOrchestra | 0.717/0.701/0.398 | 0.826/0.811/0.459 | 0.792/0.774/0.411 |
The experimental results indicate that even when all baselines use the same multi-scale segmentation head as CMD-L, CMD-L still significantly outperforms all ViT-based baselines, which fully validates the representation advantage brought by our pretraining strategy. We will add the adaptation details of ViT baselines and this controlled experiment to the paper appendix.
Response to rebuttal
The rebuttal has addressed my concerns, I decide to maintain my original score.
We sincerely thank you for your careful review and valuable feedback. Your constructive suggestions have greatly improved the rigor of our work. We are glad that our supplementary experiments and clarifications have addressed your concerns, and we will integrate all the newly added results and details into the final manuscript and appendix. Thank you again for your time and professional insights.
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper proposed a generative pretraining method to train a ConvNext model which can be used as a backbone for dense tasks like segmentation. Authors motivate that ConvNext is more suited for segmentation tasks than self-supervised ViTs because of the patching involved in ViTs, which can distort fine-grained details. The paper explores and presents design choices - the architecture used for pretraining (DiT, Attention U-Net, ConvNext), pixel space vs. VAE encoding, and the effect of a pathology foundation model as conditioning. The ConvNext is pretrained with masked diffusion where standard Gaussian noise is replaced with patch masking. Once pretrained, it is used as a feature extractor for downstream segmentation tasks by attaching a trainable segmentation head and keeping the backbone frozen. The method achieves superior performance compared to existing ViT-based pathology foundation models and end-to-end task-specific models. Further, the authors also show the scalability benefits with iterations and model size.
Strengths and weaknesses
Strengths
-
The paper is well motivated.
-
The current design choices are well presented.
-
Pretraining a ConvNext for dense tasks is interesting and novel, specifically when also using the strengths of the existing ViT models as conditioning.
Weakness
-
There is a discrepancy in metrics used in section 3 and section 4. Section 3 uses Boundary F1 score which seems to show large differences across design choices; however, this metric is not used in section 4 when comparing to other pathology foundation models.
-
There is a discrepancy in conditioning, section 3.5 and Table 3 use UNI as conditioning, but Line 170 of section 4 mentions H0-mini as conditioning. Authors need to clarify why there is this discrepancy.
-
Masked diffusion in pixel space can be treated as a special case of masked autoencoders where masking ratio is varied with timestep. If this is the case, then there needs to be ablation where the same pretraining is performed with fixed masking ratios (25%, 50%, 75%, 90%) and authors need to study whether masked diffusion is truly needed, or a simple fixed masking ratio (like in masked autoencoders) is good enough.
-
Further, the ablation effect of choice of conditioning is missing. How does changing conditioning to Virchow2 or H-optimus-1 affect the performance?
-
According to Section 4 Line 170, H0-mini is used as conditioning, but Table 4 does not benchmark against when H0-mini is used for segmentation like other pathology foundation models. This comparison is needed for fair comparison and assessment of improvements with the proposed method.
Questions
Question reflect the weakness
-
Can the authors add the boundary F1 score to the Section 4 results?
-
Why does the conditioning vary across Section 3 (UNI) and Section 4 (H0-mini)?
-
I request the authors to provide an ablation with fixed masking ratio pretraining.
-
I request the authors to provide an ablation with different pathology foundation models as conditioning.
-
I request the authors to add H0-mini as a baseline to Table 4.
I am willing to change by score if the above clarifications are provided during rebuttal.
Limitations
There is no limitations section in the paper although the author answered yes in checklist.
Final justification
The rebuttal has addressed my concerns - Boundary F1 score as metrics, H0-mini as baseline, experiments with fixed masking ratios, additional experiments with different Path foundational models as conditioning, also explanation on choice of UNI vs H0-mini. I thank the authors for putting the efforts. I am raising my score.
Formatting concerns
N/A
3 comments
Rebuttal
We sincerely appreciate your comprehensive review and highly valuable suggestions. We have supplemented corresponding experiments and clarifications one by one for all the issues you raised:
A1: Adding Boundary F1 metric to Section 4 (Response to Q1 and W1)
We have supplemented the Boundary F1 score in all comparative experiments of Section 4, and the complete results are presented as follows:
| Method | cpm15(BF1) | cpm17(BF1) | TNBC(BF1) |
|---|---|---|---|
| Pre-trained ViT-based Pathology Foundation Models | |||
| PathOrchestra | 0.467 | 0.584 | 0.481 |
| CONCHv1.5 | 0.457 | 0.581 | 0.497 |
| CONCH | 0.428 | 0.620 | 0.455 |
| Prov-Gigapath | 0.503 | 0.628 | 0.509 |
| Hibou | 0.611 | 0.658 | 0.570 |
| H-Optimus-0 | 0.584 | 0.671 | 0.565 |
| H-Optimus-1 | 0.562 | 0.665 | 0.534 |
| Kaiko | 0.529 | 0.674 | 0.554 |
| Midnight-12k | 0.403 | 0.527 | 0.413 |
| MUSK | 0.272 | 0.370 | 0.275 |
| Phikon | 0.517 | 0.630 | 0.491 |
| Phikon-v2 | 0.520 | 0.647 | 0.469 |
| UNI | 0.451 | 0.606 | 0.467 |
| UNI2-h | 0.556 | 0.643 | 0.535 |
| Virchow | 0.577 | 0.659 | 0.542 |
| Virchow2 | 0.449 | 0.608 | 0.469 |
| End-to-End Segmentation Models | |||
| nnUNet | 0.563 | 0.657 | 0.455 |
| TransUNet | 0.649 | 0.769 | 0.615 |
| ViT-Adapter | 0.853 | 0.668 | 0.661 |
| SAM Pre-trained ViT-based Pathology Foundation Models | |||
| VISTA | 0.020 | 0.011 | 0.049 |
| Pre-trained Purely Convolutional Pathology Foundation Models | |||
| CMD-L(ours) Linear Probe | 0.627 | 0.861 | 0.826 |
| CMD-L(ours) + SegHead: Fig. B2(A) | 0.911 | 0.875 | 0.874 |
| CMD-L(ours) + SegHead: Fig. B2(B) | 0.947 | 0.866 | 0.838 |
We will add this metric to Table 4 in the main text accordingly, to ensure consistency of the experimental evaluation system throughout the paper.
A2: Explanation for the discrepancy in conditioning models (Response to Q2 and W2)
The adoption of different foundation models in the ablation study of Section 3.5 and the main experiments of Section 4 is motivated by the consideration of fair comparison in terms of parameter count:
- The ablation study in Section 3.5 is a proof-of-concept experiment focusing on verifying the effectiveness of conditioning, so we selected the UNI model for validation.
- The main experiments in Section 4 aim for fair comparison with existing baselines, so we adopted H0-mini with a smaller parameter size: the total parameter count of CMD-L+H0-mini is 602M, which is on the same scale as most mainstream ViT baselines. If UNI were used instead, the total parameter count of CMD-L+UNI would reach 823M, significantly higher than most baselines, which would introduce performance interference from the parameter count advantage and be unfavorable for fair comparison.
Meanwhile, we have supplemented comprehensive ablations with different foundation models as conditioning (see the table in A4 for details), which proves that CMD consistently achieves excellent performance regardless of which pathology foundation model is selected.
A3: Ablation comparison between fixed masking ratios and dynamic timestep-varying masking (Response to Q3 and W3)
Thank you very much for your insightful comments. We fully agree that this comparison is of critical significance to verifying the core value of the masked diffusion paradigm. Therefore, we have supplemented 4 complete pretraining ablation experiments with fixed masking ratios (25%, 50%, 75%, 90%). All experiments maintain exactly the same pretraining data, backbone architecture, training steps and downstream evaluation protocol, with only the dynamic timestep-varying masking replaced by fixed-ratio masking. The results are as follows:
| Mask Ratios | cpm15(Dice / BF1) | cpm17(Dice / BF1) | Janowczyk(Dice / BF1) | kumar(Dice / BF1) | TNBC(Dice / BF1) |
|---|---|---|---|---|---|
| 25% | 57.31 / 50.90 | 73.39 / 70.78 | 52.45 / 15.28 | 57.51 / 53.78 | 69.77 / 70.42 |
| 50% | 62.89 / 58.50 | 71.45 / 63.33 | 52.12 / 12.66 | 59.24 / 56.11 | 68.75 / 64.01 |
| 75% | 57.89 / 51.96 | 70.41 / 67.14 | 52.36 / 16.03 | 55.02 / 55.16 | 58.66 / 48.05 |
| 90% | 56.80 / 50.47 | 75.16 / 71.96 | 52.41 / 16.57 | 61.05 / 63.68 | 74.18 / 75.87 |
| Dynamic Timestep-varying Masking(ours) | 63.25 / 56.03 | 76.74 / 73.45 | 53.66 / 18.24 | 62.76 / 62.25 | 73.51 / 75.63 |
Three clear conclusions can be drawn from the experimental results:
- Overall performance advantage: The dynamic timestep-varying masking scheme outperforms all single fixed-ratio schemes on most datasets, achieving the best overall performance.
- No universally optimal fixed ratio: Different fixed ratios show large performance fluctuations across different datasets, and there is no cross-dataset universally optimal masking ratio.
- Generalization stability: The dynamic timestep-varying scheme achieves optimal or near-optimal performance on all 5 datasets without any performance collapse, delivering the most stable cross-dataset generalization. This property of requiring no tuning for downstream tasks and stable cross-scenario adaptation is particularly critical for the transfer application of pathology foundation models across organs, staining protocols and scanners.
Mechanism analysis: We believe the core advantage of dynamic timestep-varying masking stems from its continuous difficulty learning process that conforms to the essence of diffusion models: 1000 timesteps correspond to a smooth transition of masking ratio from nearly 0 to nearly 1, fully covering the full difficulty spectrum of "local texture inpainting — medium-region completion — global structure reasoning". During training, the model randomly samples reconstruction tasks of different difficulties, and is forced to learn both fine-grained cell morphology and global tissue distribution patterns simultaneously. The resulting learned feature representations are richer in granularity and stronger in robustness, which cannot be achieved by masked autoencoder schemes with discrete fixed masking ratios.
We will add this complete set of ablation experiments and mechanism analysis to the paper appendix. We thank you again for your valuable suggestions.
A4: Ablation experiments with different pathology foundation models as conditioning (Response to Q4 and W4)
We have supplemented the experimental results of CMD-L equipped with different pathology foundation models (UNI, Virchow2, H-optimus-1) as conditioning, as shown in the table below:
| Method | cpm15(Dice / Pre / BF1) | cpm17(Dice / Pre / BF1) | TNBC(Dice / Pre / BF1) |
|---|---|---|---|
| CMD-L (H0-mini) | 0.889/0.885/0.947 | 0.880/0.883/0.866 | 0.854/0.830/0.838 |
| CMD-L (H-optimus-1) | 0.906/0.915/0.862 | 0.896/0.909/0.789 | 0.861/0.865/0.751 |
| CMD-L (UNI) | 0.902/0.924/0.844 | 0.894/0.900/0.783 | 0.868/0.868/0.764 |
| CMD-L (Virchow2) | 0.913/0.906/0.873 | 0.888/0.904/0.772 | 0.863/0.861/0.752 |
The results indicate that CMD-L maintains stable and excellent performance when different mainstream pathology foundation models are used as conditioning, which verifies the generalizability and compatibility of the conditioning module.
A5: Adding H0-mini as a baseline (Response to Q5 and W5)
We have added H0-mini as a comparison baseline in Table 4. The experimental results under exactly the same downstream evaluation protocol are presented as follows (metric format: Dice / Precision / Boundary F1):
| Method | cpm15(Dice / Pre / BF1) | cpm17(Dice / Pre / BF1) | TNBC(Dice / Pre / BF1) |
|---|---|---|---|
| H0-mini | 0.776/0.788/0.563 | 0.878/0.889/0.675 | 0.841/0.805/0.557 |
| CMD-L(H0-mini)(ours) | 0.889/0.885/0.947 | 0.880/0.883/0.866 | 0.854/0.830/0.838 |
This result clearly demonstrates the significant performance gain brought by our masked diffusion pretraining scheme on the basis of H0-mini semantic conditioning, making the comparison logic more rigorous and fair.
Response to rebuttal
The rebuttal has addressed my concerns - Boundary F1 score as metrics, H0-mini as baseline, experiments with fixed masking ratios, additional experiments with different Path foundational models as conditioning, also explanation on choice of UNI vs H0-mini. I thank the authors for putting the efforts. I am raising my score.
One thing remains unresolved. The paper does not clearly discuss the limitations. I had raised this in the initial review - "There is no limitations section in the paper although the author answered yes in checklist." Authors need to clearly discuss the limitations. Just mentioning the future direction is not sufficient.
We thank the reviewer for acknowledging our additional experiments, and sincerely appreciate your numerous constructive comments throughout the review process. We will integrate the relevant clarifications and supplementary experimental results into the final version to further refine the presentation and argumentation quality of the paper.
Meanwhile, we also thank the reviewer for pointing out that the paper does not clearly elaborate on the limitations. In the revised version, we will add a dedicated Limitations section to explicitly state the limitations of this study in the following two aspects:
1. Distributional bias in pretraining data
The pretraining data of our model is built upon the HistAI pathology dataset, which carries a certain degree of distributional skew across organ sources and staining types. The transfer generalization performance of the model on pathology images from rare organs, rare disease entities, and special staining modalities has not been fully validated. Incorporating larger-scale, more diverse, and better-balanced datasets in follow-up work is expected to further enhance the generalizability of the model.
2. Limited scope of downstream adaptation strategies
The core goal of this study is to verify the representation quality learned via masked-diffusion convolutional pretraining. To rule out confounding effects from fine-tuning strategies and ensure fair comparison across different foundation models, all downstream tasks uniformly follow the pure representation probing paradigm: the backbone is kept fully frozen, and only the lightweight segmentation head is trained, with no updates to the pretrained backbone parameters at any stage. Constrained by this experimental design, we have not explored adaptation schemes that update backbone parameters for the ConvNeXt-UNet architecture, such as parameter-efficient fine-tuning and partial layer unfreezing. These directions can be further extended in future work.
The above content will be fully incorporated into the Limitations section of the paper. We thank the reviewer again for your valuable suggestions, which significantly contribute to improving the rigor and completeness of our work.
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The authors propose a novel framework for cell-level dense prediction that alleviate the current limitations of ViTs that disrupt the spatial continuity through the patch tokenization. They introduce ConvNext Masked-Diffusion, a self-supervised technique that leverage masked-diffusion, coupled with pathology foundation model feature conditioning as a complementary semantic guidance through adaLN conditioning. The method compete and sometimes outpeforms SOTA method, especially in limited data annotation scenario, showing that, CNN-based architectures can still perform very well compared to the SOTA methods mosly all based on transformers.
Strengths and weaknesses
- $\textbf{S1}: $ The paper challenges a bit the current literature, showing that CNN-based models can outperform Vit-based ones.
- $\textbf{S2}: $ There are many different methodological contributions, and each of them is well motivated. The authors notably discusses the choice of architectures (Section 3.2), the reason why they use masked diffusion instead of DDPM (section 3.3), the choice of working in the pixel space instead of latent space (Section 3.4), the benefits of using foundation model as conditioning (Section 3.5) and finally how their method scale with respect to training time and model capacity (Section 4.4).
- $\textbf{S3}: $ In the evluation, many other methods have been benchmarked to compare with their method, and confidence intervals have been reported.
- $\textbf{S4}: $ There are quantitative results comparing the proposed method with the others SOTA, supporting their claim about spatial continuity.
- $\textbf{S5}: $ The code is public and seems to be very clean. There also many helpful details on the appendix.
- $\textbf{W1}: $ One of the main problem I have is the evaluation part. Even though many different methods have been benchmarked, it is not clear what segmentation head was used for all the foundation models (UNI, UNI-2h, ...). One bigger problem I have is that, from my understanding, all the other methods the proposed method is compared with, they don't have a segmentation head that leverages multi-scale features. We can see from the table that, when doing linear probing, the results are much lower than the other methods. So my question is : does the boost of perfomrance comes from the pretraining, or from the segmentation head that uses multi scale features ? It is quite difficult for me to understand what brings the boost of performance. An experiment to isolate this would be nice. Moreover, to fairly comapre with the other baselines, the authors should also use a semgentation head that levearge mutli scale features. Indeed, even if the other models are not CNN-based, but moslty Vit-based, we can still leverage the features from the differnet layers of the ViT (even if the features are of same dimension, they still represent low and high level concepts depending on layer).
- $\textbf{W2}: $ It is not super clear what foundation models is used for the conditioning. In the section 4.1.1, it is mentioned H0-mini, but for some reasons the Section 3.5 mentions UNI model. Is it a typo, or did you use two different foundation models, and if yes, if you can please justify it. Moroever, it seems that the method is evaluated using H0-mini conditioning. Having one or two different versions of CMD-L in the Table 4 with different pathology foundation model as conditoning would strenghten more the results.
Questions
Here are all the questions that can push me to increase my score.
- $\textbf{Q1}: $ The first question I have is : where does the nice performance come from ? From the pretraining stategy, or from the segmentation head ? An experiment to isolate these two components would be nice.
- : My second concern is about how the other methods are evaluated. I thinkn there really should be a comparison with the other methods but with a segmentation that leverage multi scale features.
- : Having CMD-L models in the Table 4 with different pathology foundation model as conditoning would strenghten more the results.
Limitations
Yes
Final justification
The paper is well motivated and has interesting methodological contributions. The authors answered my main concerns during the rebuttal, which is is why I increase my grade to Bordeline Accept.
Formatting concerns
N/A
3 comments
Rebuttal
We sincerely appreciate your detailed review and valuable suggestions for improvement. We respond to your questions one by one and have supplemented corresponding experiments as follows:
A1: Verification of the source of performance improvement (Response to Q1 and W1)
Regarding W1, we first supplement the downstream segmentation adaptation scheme of ViT-based pathology foundation models in the original manuscript: for all baseline models, we adopt the patch tokens output by the last Transformer layer, with the shape of where denotes the total number of patches and is the feature embedding dimension. The patch tokens are converted into a dense feature map via deterministic reshape. Then a lightweight decoder (3×3 convolution for channel adjustment + stepwise bilinear upsampling) is applied to restore the input resolution, and finally the segmentation head produces pixel-level predictions.
For the core question raised in Q1 and W1 — whether the performance gain comes from the pretraining strategy or the multi-scale segmentation head — as well as the fairness of baseline comparison, we have supplemented a controlled experiment with a unified multi-scale segmentation head. Both CMD and all ViT baselines adopt a multi-scale segmentation head with exactly the same architecture, whose design is consistent with the right panel of Figure B2 in the appendix: we select outputs from Transformer layers corresponding to the hierarchical features of CMD-L downstream, align their resolutions via upsampling, perform feature concatenation, and then generate predictions after channel reduction via a lightweight 3×3 convolution. All experiments keep the backbone frozen and follow exactly the same training protocol for the segmentation head.
The experimental results with the unified multi-scale segmentation head are presented below (metric format: Dice / Precision / Boundary F1):
| Method | cpm15(Dice / Pre / BF1) | cpm17(Dice / Pre / BF1) | TNBC(Dice / Pre / BF1) |
|---|---|---|---|
| CMD-L(ours) | 0.889/0.885/0.947 | 0.880/0.883/0.866 | 0.854/0.830/0.838 |
| UNI-v1 | 0.725/0.715/0.435 | 0.834/0.817/0.501 | 0.792/0.748/0.378 |
| UNI-v2 | 0.758/0.734/0.502 | 0.847/0.842/0.554 | 0.809/0.776/0.450 |
| CONCH-v1 | 0.732/0.710/0.456 | 0.836/0.848/0.521 | 0.796/0.780/0.400 |
| CONCH-v1.5 | 0.729/0.713/0.458 | 0.843/0.827/0.522 | 0.802/0.785/0.439 |
| Virchow-v1 | 0.752/0.752/0.526 | 0.849/0.839/0.556 | 0.817/0.788/0.470 |
| Virchow-v2 | 0.759/0.740/0.513 | 0.848/0.838/0.567 | 0.815/0.779/0.467 |
| Phikon | 0.731/0.721/0.452 | 0.834/0.824/0.495 | 0.804/0.780/0.431 |
| Phikon-v2 | 0.726/0.719/0.436 | 0.835/0.822/0.504 | 0.794/0.769/0.400 |
| GigaPath | 0.731/0.715/0.440 | 0.838/0.831/0.515 | 0.802/0.773/0.427 |
| Hibou-L | 0.767/0.746/0.540 | 0.856/0.861/0.589 | 0.820/0.804/0.486 |
| H-Optimus-0 | 0.762/0.754/0.521 | 0.858/0.842/0.587 | 0.820/0.788/0.477 |
| H-Optimus-1 | 0.756/0.757/0.515 | 0.858/0.851/0.593 | 0.815/0.786/0.469 |
| Kaiko-ViT-L/14 | 0.768/0.760/0.533 | 0.855/0.851/0.587 | 0.814/0.791/0.460 |
| Midnight-12k | 0.742/0.731/0.473 | 0.842/0.825/0.533 | 0.804/0.770/0.428 |
| MUSK | 0.686/0.690/0.318 | 0.741/0.730/0.371 | 0.713/0.690/0.289 |
| PathOrchestra | 0.717/0.701/0.398 | 0.826/0.811/0.459 | 0.792/0.774/0.411 |
Experimental conclusion: Under the fair setting where all baselines use the same multi-scale segmentation head, CMD-L still significantly outperforms all ViT-based pathology foundation models. This verifies that the performance improvement of our method primarily stems from the masked-diffusion pretraining strategy, rather than the design difference of the segmentation head. We will add this set of experiments and the detailed segmentation head design to the paper appendix.
A2: Fair comparison with baselines (Response to Q2)
In response to the concern in Q2 that other methods should also be evaluated with a segmentation head leveraging multi-scale features to ensure fairer comparison, we have supplemented the controlled experiment with the unified multi-scale segmentation head, and the results are shown in the table of A1. Experiments confirm that the performance gain of our method is mainly attributed to the masked-diffusion pretraining strategy, not the design of the multi-scale feature segmentation head. We will add this part of experiments and the details of the segmentation head to the paper appendix.
A3: Explanation of conditioning model discrepancy and verification of generalizability (Response to Q3 and W2)
The inconsistency of foundation models between Section 3.5 and Section 4.1.1 is not a typo. We adopted different models in different experimental phases out of consideration for fair comparison in terms of parameter count:
- The ablation study in Section 3.5 focuses on verifying whether the conditioning module is effective, so we selected the UNI model for proof-of-concept verification.
- For the main experiments in Section 4.1.1, to match the parameter scale of baseline models, we selected H0-mini with smaller parameter size as the conditioning: the total parameter count of CMD-L(H0-mini) is 602M, which is comparable to most mainstream ViT baselines and facilitates fair comparison. If we kept using the UNI model, the total parameter count of CMD-L(UNI) would reach 823M, exceeding that of most baselines and being unfavorable for fair comparison.
To verify the generalizability of the conditioning module, following your suggestion, we have supplemented the experimental results of CMD-L with different pathology foundation models as conditioning in Table 4, as shown below (metric format: Dice / Precision / Boundary F1):
| Method | cpm15(Dice / Pre / BF1) | cpm17(Dice / Pre / BF1) | TNBC(Dice / Pre / BF1) |
|---|---|---|---|
| CMD-L (H0-mini) | 0.889/0.885/0.947 | 0.880/0.883/0.866 | 0.854/0.830/0.838 |
| CMD-L (H-optimus-1) | 0.906/0.915/0.862 | 0.896/0.909/0.789 | 0.861/0.865/0.751 |
| CMD-L (UNI) | 0.902/0.924/0.844 | 0.894/0.900/0.783 | 0.868/0.868/0.764 |
| CMD-L (Virchow2) | 0.913/0.906/0.873 | 0.888/0.904/0.772 | 0.863/0.861/0.752 |
The results show that CMD-L maintains excellent performance when different pathology foundation models are used as conditioning, which proves that the conditioning module has good generalizability and compatibility. We will add this part of results to Table 4 and the corresponding section in the main text.
Thank you for your detailed rebuttal and for the additional experiments you conducted.
The new experiments with the multi-scale segmentation head adress my main concern. It is now more clear that the boost of performance seems to come from the masked-diffusion pretraining strategy, and not from the segmentation head. I appreciate that you applied the exact same multi-scale head to all the ViT baselines, since this makes the comparison morne fair. The results are now more convincing.
Thanks also for adding the different pathology foundation models as conditioning in Table 4, this strenghten the results and shows the conditioning module generalizes well.
Given that all my concerns have been adressed, I will increase my score.
Thank you very much for your thoughtful follow-up and for recognizing our additional experiments. We sincerely appreciate your constructive feedback throughout the review process. We will incorporate these clarifications and experimental results into the final manuscript to further improve its quality, and we will continue exploring this research direction in future work. Thank you again for your valuable time and support.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Response to the Meta Review
We thank the Area Chair for the concise and accurate summary of our contributions, and for pinpointing the two issues that determine the outcome of this submission: (i) where the claimed performance improvement actually comes from, and (ii) whether the requested evaluations and experiments have been provided. We address both directly below, and note that all requested experiments have been completed and reported in the individual rebuttals to Reviewers m7zr, 21kp, and mGvi.
1. The source of the performance gain: four controlled experiments that isolate pretraining
The concern shared by the reviewers is that our gain might come from the multi-scale segmentation head, from the ConvNeXt architecture, or from the conditioning foundation model, rather than from masked-diffusion pretraining. We therefore ran four ablations, each of which removes exactly one candidate explanation while keeping the backbone frozen and the training protocol identical. Averaged over CPM15 / CPM17 / TNBC:
Three points we would highlight for the AC:
The gain survives every single control. Once all ViT baselines are equipped with our multi-scale head, CMD-L still leads by +6.0 Dice percentage points and, more importantly, by +34.6 Boundary F1 percentage points. The performance advantage of CMD-L therefore persists under the unified setting.
The gain is concentrated exactly where our motivation predicts it should be. Under a unified head, the Dice gap is moderate, while the boundary-level gap remains substantial. This confirms that our pretraining preserves spatial continuity: even with multi-scale intermediate ViT features, patch tokenization degrades nuclear boundaries, and no segmentation head can recover details lost during encoding. This provides strong evidence that the gain stems from learned feature representations rather than architectural adjustments.
The conditioning model is a complement, not the source. H0-mini used alone as a backbone reaches 0.832 Dice / 0.598 BF1; the same H0-mini used as adaLN conditioning on top of our pretrained ConvNeXt reaches 0.874 / 0.884. Conversely, swapping the conditioning model (UNI, Virchow2, H-Optimus-1) changes performance only marginally, and all configurations outperform H0-mini used alone, so the framework is not dependent on one particular foundation model.
2. Status of every requested evaluation and experiment
All requested experiments and clarifications were completed:
These additions required new computation, including 17 re-trained segmentation heads, seven full pretraining runs, and a new PanNuke benchmark.
3. The nature of the reviewers' concerns
We would note that the issues raised by Reviewers m7zr and 21kp concern evaluation completeness and comparison fairness, not the soundness, novelty, or clarity of the method itself. Neither reviewer disputed the pretraining formulation, the conditioning mechanism, or the correctness of the results; what they asked for was the evidence needed to attribute the observed gains correctly.
The additional evaluation asked for by the reviewers strengthens the original conclusion under every configuration we were asked to test, and we could not identify a setting in which the advantage disappears.
We also emphasise the broader takeaway that we believe is worth bringing to the community: under a fair, architecture-matched protocol, convolutional masked-diffusion pretraining outperforms 17 ViT-based pathology foundation models on cell-level dense prediction, especially at object boundaries. The controlled experiments in this rebuttal further support this conclusion.
We thank the AC and all reviewers for their constructive feedback, which has substantially strengthened the evaluation and presentation of this work.