potentialpaper

RadarFlowPose: Vision-Inspired Coarse-to-Fine Skeleton Refinement with Flow Matching

Kailu Guo, Akram Alomainy, Khalid Z. Rajab

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

TL;DR. Vision-inspired RadarFlowPose performs coarse-to-fine skeleton refinement with Flow Matching to improve mmWave radar-based 3D human pose estimation from sparse and noisy observations.

Abstract. Radar-based human pose estimation is a promising alternative to camera-based perception, but remains challenging due to sparse observations, noisy measurements, and severe pose ambiguity. Existing methods infer both global skeletal structure and flexible peripheral joints from sparse radar observations, often compromising structural plausibility and fine-grained local accuracy. Motivated by the coarse-to-fine nature of human visual perception, we propose RadarFlowPose, a framework that decomposes radar-based human pose estimation into coarse pose prior generation and flow-based refinement. The coarse model first produces a structurally plausible and temporally coherent pose prior from sparse radar observations, providing a global initialization for subsequent refinement. Instead of estimating the full pose from scratch, the refinement stage focuses on correcting the remaining local ambiguities and motion-induced errors. By incorporating localised Doppler motion cues into the flow-matching process, the model performs motion-aware residual refinement around the coarse prior, leading to more accurate and anatomically consistent pose estimates. Experiments on three benchmark radar pose datasets show consistent effectiveness, especially in motion-sensitive and fine-grained joint-level evaluation.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
28 Apr 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:50 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

The paper presents a coarse-to-fine, 2-stage estimation model for post estimation using radar/doppler signals. While there is precedent for such approaches, the architecture, the staging of flow initialization and refinement and representations of doppler signals are driving the proposed new model. The proposal is evaluated on relevant datasets (although there are concerns, see below).

The proposed ideas of initializing flow via coarse pose estimation, refining estimates via Doppler statistics, two-stage cascade to separate tuning errors from bad initialization; and broadly the approach to solving the problem are the key strengths. However, lack of critical ablations/evaluations, unclear evidence on benefits of the different stages of the cascade are the critical weaknesses.

The reviewers clearly highlighted various areas of improvement. I would request the authors to address their questions to support the case for publication. Specifically,

  • crucial evidence is missing to support the flow matching and the later flow refinement via doppler aggregation are providing the relevant benefits; the reviewers highlighted how to setup such an ablation to tease apart the benefits;
  • various technical details on architectures (decoder setup), dataset selections and evaluation summaries (like choices of hyperparameters etc) need clarifications
Final justification

Appreciate the reviewers for engaging in a healthy conversation. The various critical issues regarding missing technical and implementation details have in fact been addressed; and the authors also added in various baselines to substantiate the case for publication, justifying the evaluation schemes. Few things are clear - global doppler gives critical signal, the flow matching setup captures the fine grained skeletal structure better; and broadly the baselines could be better (especially the direct-RR is too naive for its own sake). The findings from this work could have impact in other frameworks that rely on radar signals for generative AI modeling/synthesis. The paper is quite well written.

Overall, there are valuable findings in here that warrants publication.

Area Chair p8op · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

The paper presents a coarse-to-fine, 2-stage estimation model for post estimation using radar/doppler signals. While there is precedent for such approaches, the architecture, the staging of flow initialization and refinement and representations of doppler signals are driving the proposed new model. The proposal is evaluated on relevant datasets (although there are concerns, see below).

The proposed ideas of initializing flow via coarse pose estimation, refining estimates via Doppler statistics, two-stage cascade to separate tuning errors from bad initialization; and broadly the approach to solving the problem are the key strengths. However, lack of critical ablations/evaluations, unclear evidence on benefits of the different stages of the cascade are the critical weaknesses.

The reviewers clearly highlighted various areas of improvement. I would request the authors to address their questions to support the case for publication. Specifically,

  • crucial evidence is missing to support the flow matching and the later flow refinement via doppler aggregation are providing the relevant benefits; the reviewers highlighted how to setup such an ablation to tease apart the benefits;
  • various technical details on architectures (decoder setup), dataset selections and evaluation summaries (like choices of hyperparameters etc) need clarifications
Final justification

Appreciate the reviewers for engaging in a healthy conversation. The various critical issues regarding missing technical and implementation details have in fact been addressed; and the authors also added in various baselines to substantiate the case for publication, justifying the evaluation schemes. Few things are clear - global doppler gives critical signal, the flow matching setup captures the fine grained skeletal structure better; and broadly the baselines could be better (especially the direct-RR is too naive for its own sake). The findings from this work could have impact in other frameworks that rely on radar signals for generative AI modeling/synthesis. The paper is quite well written.

Overall, there are valuable findings in here that warrants publication.

1 comment
Authors · CommentOpenReview ↗

We sincerely thank the Area Chair for the careful assessment, constructive guidance, and recognition of our work.

Following the recommendations in the meta review, we focused our revision on providing direct evidence for the two main methodological contributions. First, we added a controlled Direct-RR baseline to isolate the benefit of Flow Matching. Direct-RR consistently underperforms RadarFlowPose across all three datasets, directly supporting the advantage of progressive, state-dependent flow refinement over one-step residual prediction.

Second, we added controlled ablations comparing No Doppler, Global Doppler, and Localized Doppler. Localized Doppler achieves the best overall performance across all three datasets, whereas global aggregation does not consistently improve upon removing Doppler entirely. A neighbourhood-radius sensitivity analysis further confirms the effectiveness of the selected local aggregation range. These results show that the improvement comes specifically from associating Doppler evidence with the evolving joint locations.

We also clarified the decoder architecture, training and inference procedures, hyperparameter choices, dataset settings, and unified evaluation protocol. In addition, repeated training runs show small standard deviations across all three datasets, while the complete model maintains high inference efficiency, confirming that the proposed refinement is both stable and computationally practical.

We believe these additional experiments and clarifications directly address the key concerns identified in the meta review by validating the Flow-Matching refinement, confirming the contribution of localized Doppler aggregation, and clarifying the role of each stage in the cascade. We hope that the revised manuscript now provides sufficiently strong evidence to enable a favourable assessment of the work.

Reviewer JjgcOpenReview ↗
Rating
5/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
2/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper presents a two-stage approach for 3D human pose estimation from sparse mmWave radar point clouds. A coarse stage first produces a kinematically constrained skeleton prior, which is then refined by a Flow-Matching model initialized from a perturbed coarse pose rather than random noise. The refinement process leverages localized Doppler features and skeleton-topology-aware attention to predict residual pose corrections. Evaluations on MM-Fi, mmBody, and Reb3D demonstrate strong performance, with the method achieving the best average PA-MPJPE among the compared baselines.

Strengths and weaknesses

Strengths

S1. The paper is likely the first to apply Flow Matching to radar-based skeleton refinement. While the novelty is relatively focused, it represents a meaningful departure from prior diffusion-based approaches.

S2. Initializing the Flow-Matching process from the coarse pose prediction, rather than using the coarse pose only as a conditioning signal, is a well-motivated design choice. This component is supported by both the initialization ablation in Table 4 and the integration-step analysis in Fig. 10, making it one of the most thoroughly validated aspects of the method.

S3. The localized Doppler aggregation mechanism is a promising idea. By conditioning Doppler features on the evolving pose state, the method aims to inject motion information in a more localized and physically meaningful manner than global aggregation schemes.

Weaknesses

W1. The localized Doppler mechanism is not independently validated. Although it is presented as a key component of the method, the paper does not include an ablation comparing localized and global Doppler aggregation, nor a comparison with removing the Doppler token entirely. Sensitivity to the aggregation radius or Gaussian weighting parameter is also not examined. Consequently, it remains unclear whether the observed gains are attributable to the localized design itself.

W2. Because the Doppler component is not isolated experimentally, the evidence supporting the overall contribution remains incomplete. The benefit of using the coarse pose as the Flow-Matching source is clearly demonstrated, whereas the contribution of the Doppler mechanism remains uncertain.

W3. The comparison omits the most recent radar point-cloud methods — e.g., mmChainPose (reports on mmBody) and mmGAT, which the paper itself cites ([21]). Of course, most of the work that wasn't compared didn't publish its code, so this isn't very important.

Questions

Q1. The localized Doppler aggregation is presented as a central component of the method, yet its contribution is not isolated experimentally. Could the authors provide an ablation study comparing the proposed localized Doppler design with a global Doppler variant, and ideally a version without Doppler features?

The main factor that will influence my final assessment is whether the contribution of the localized Doppler mechanism can be demonstrated more convincingly.

Q2. Please report variance for the main results in Tables 1–3. Several improvements over mmDiff are relatively modest (for example, on Reb3D), making it difficult to assess their statistical significance. Reporting mean ± std would help establish the robustness of the reported gains.

Q3. The benefits of the flow-refinement stage are not entirely clear from the current results. In several settings, the full model improves PA-MPJPE while providing limited gains, or even showing slight degradation, in MPJPE and bone-length error relative to the coarse-only variant (SRL+LTA+KPC). Could the authors discuss the conditions under which flow refinement is most beneficial and whether the additional inference cost is justified in practice?

Limitations
  1. Scope of the empirical support. The benefit of the most novel component, the localized Doppler mechanism, is not isolated through any ablation study, and the main comparisons (Tables 1–3) are based on single runs. The authors could acknowledge that the contribution of the Doppler mechanism and the statistical significance of the headline improvements remain to be established.

  2. Metric-dependent benefit. The flow-refinement stage improves PA-MPJPE and joint velocity but is neutral or negative with respect to MPJPE and mean bone-length error in several settings. It would be more accurate to state explicitly, as a limitation, that the refinement primarily improves articulated structure and motion consistency rather than absolute joint-position accuracy.

Final justification

The rebuttal resolves my main concerns:

The localized Doppler mechanism is now directly validated against both No-Doppler and Global-Doppler variants across all three datasets, together with a neighborhood-radius sensitivity analysis.

Multiple-run results with small standard deviations support the stability of the reported improvements.

The authors also clarified that the refinement mainly improves articulated structure and motion consistency, while gains in absolute MPJPE are more limited.

The novelty remains focused on the integration of existing components, but the new evidence sufficiently supports the main technical contribution. I therefore raise my rating to 5 (Accept).

Formatting concerns

not specifically

1 comment
Authors · RebuttalOpenReview ↗
Rebuttal

We sincerely thank the reviewer for the thoughtful and constructive comments. The questions have helped us present the motivation and contributions of our work more clearly, strengthen several technical explanations, and improve the overall quality of the manuscript.

W1 Response:

Thank you for this suggestion. We conducted a controlled ablation with three variants: No Doppler, Global Doppler, and the proposed Localized Doppler. All experimental settings were kept identical, with the Doppler representation being the only changed component.

In the No Doppler variant, the Doppler token is removed. In the Global Doppler variant, Doppler features are aggregated over the entire radar frame and shared across all joints. In the proposed Localized Doppler variant, Doppler features are aggregated separately around each joint to provide joint-specific motion cues. The comparison was conducted on all three datasets, as reported in the following table.

Doppler Mode mmBody MPJPE ↓ mmBody PA-MPJPE ↓ MM-Fi MPJPE ↓ MM-Fi PA-MPJPE ↓ ReB3D MPJPE ↓ ReB3D PA-MPJPE ↓
None 85.07$\pm$ 0.18 62.41$\pm$ 0.35 69.63$\pm$ 0.77 50.99$\pm$ 0.71 67.18$\pm$ 0.34 54.30$\pm$ 0.24
Global 82.78$\pm$ 0.13 64.10$\pm$ 0.38 67.89$\pm$ 0.22 52.63$\pm$ 0.67 67.39$\pm$ 0.19 57.61$\pm$ 0.20
Localized 74.37 ±\pm 0.33 55.71 ±\pm 0.21 66.09 ±\pm 0.36 50.47 ±\pm 0.17 64.29 ±\pm 0.23 53.97 ±\pm 0.35

The results consistently support the proposed localized Doppler design. Localized Doppler achieves the best MPJPE and PA-MPJPE on all three datasets. Notably, global aggregation does not consistently improve upon removing the Doppler token, suggesting that indiscriminate frame-level Doppler aggregation may introduce motion cues unrelated to individual joints. In contrast, the proposed localized aggregation associates Doppler evidence with the evolving joint locations and provides more relevant joint-specific motion information.

To examine the sensitivity of localized Doppler aggregation, we varied the neighbourhood radius rr on mmBody while keeping all other settings unchanged. For each joint, Doppler features were aggregated only from radar points within radius rr. The Gaussian width was coupled to the radius as σ=r/2\sigma=r/2, so this experiment also evaluates the effect of the weighting scale.

Radius rr (m) MPJPE (mm) ↓ PA-MPJPE (mm) ↓
0.025 77.32 57.56
0.050 79.63 59.03
0.100 74.37 55.71
0.150 80.78 60.10
0.200 76.15 56.30

The radius has a clear influence on the final performance, as it determines the spatial range from which joint-specific Doppler evidence is collected. We selected r=0.10r=0.10 m based on the typical local scale of the human skeleton, so that the neighbourhood is sufficiently large to include useful radar returns without extending excessively into adjacent body regions. The results support this empirical choice, with r=0.10r=0.10 m achieving the best MPJPE and PA-MPJPE among the tested settings. The corresponding Gaussian width is σ=0.05\sigma=0.05 m.

W2 Response:

This point has also been addressed in our response to W1. Please refer to the Doppler-mode and neighbourhood-radius ablations and the accompanying analysis above.

W3 Response:

Thank you for pointing this out. mmChainPose reports an MPJPE of 65.8 mm and an OKS of 0.6320 on mmBody. However, neither mmChainPose nor mmGAT provides an official public implementation. We therefore did not include them in the baseline table, as an independent reimplementation could introduce avoidable implementation bias. Our comparisons are limited to radar point-cloud methods that can be fully reproduced and retrained under the same protocol.

Q1 Response:

This point has been addressed in detail in our response to W1. The added ablations consistently show that Localized Doppler outperforms both Global Doppler and No Doppler across all three datasets, directly supporting the contribution highlighted in this question. Please refer to W1 for the full results and accompanying analysis.

Q2 Response:

Thank you for this suggestion. We repeated RadarFlowPose with multiple independent training seeds and now report the mean ±\pm standard deviation on all three datasets. The results are 74.37 ±\pm 0.33 / 55.71 ±\pm 0.21 mm on mmBody, 66.09 ±\pm 0.36 / 50.47 ±\pm 0.17 mm on MM-Fi, and 64.29 ±\pm 0.23 / 53.97 ±\pm 0.35 mm on ReB3D for MPJPE/PA-MPJPE, respectively. The small standard deviations indicate that RadarFlowPose is stable across independent runs.

We are also updating Tables 1–3 to report the mean ±\pm standard deviation wherever repeated runs are available. For mmDiff, we attempted to reproduce the reported results using the released code, but the reproduced performance differed substantially from that obtained using the released pretrained weights. We therefore used the pretrained model for evaluation, which does not allow training variance to be estimated.

In addition, the pretrained model is fixed to a 17-joint skeleton. ReB3D therefore had to be reduced from 27 to 17 joints for mmDiff, whereas RadarFlowPose was evaluated on all 27 joints. We will state this clearly below the table, and the relatively close ReB3D results should therefore be interpreted with caution.

Q3 Response:

Thank you for this comment. To clarify where the refinement stage is most useful, we report the joint-wise errors of the coarse-only model and RadarFlowPose on ReB3D. RadarFlowPose reduces MPJPE for 18 of the 27 joints and PA-MPJPE for 21 of the 27 joints, with 14 joints improved under both metrics.

The gains are not uniformly distributed across the skeleton but are concentrated in the most challenging articulated regions. RadarFlowPose reduces MPJPE for all eight lower-limb joints and consistently improves the distal hand joints under both MPJPE and PA-MPJPE. This distribution is consistent with the intended role of Flow Matching: preserving the already plausible global skeleton while refining residual errors in peripheral joints that are difficult to recover from sparse radar observations.

The absolute per-joint gains are modest, but their distribution is consistent with the intended role of the refinement stage. The coarse model already estimates the global body position and many torso joints reasonably well, leaving less room for improvement in these regions. Flow refinement is therefore most useful when the remaining errors arise from local limb articulation and relative joint configuration. This also helps explain why the improvement is more consistently reflected in PA-MPJPE than in overall MPJPE.

Bone-length error is not explicitly included in the Flow-Matching objective and therefore does not improve in every setting. However, the refinement improves bone-length consistency on MM-Fi and ReB3D, as shown in Figs. 6 and 7.

The refinement stage is most beneficial when the coarse estimator has already recovered a plausible global skeleton but still exhibits residual errors at challenging peripheral joints, such as the hands, feet, and head. Its role is therefore to preserve the coarse skeletal structure while making targeted local corrections, so the improvements are naturally concentrated on difficult joints rather than the entire skeleton. The coarse estimator itself is lightweight (3.07M parameters), while the complete system still processes a 297-frame sequence in 79.77 ms (0.2686 ms/frame, 3723.16 FPS) and remains substantially faster than mmDiff. We therefore believe that the modest computational overhead is well justified by the improved pose refinement.

We will add the joint-wise results and qualitative examples and clarify that Flow refinement mainly improves local articulation and relative skeletal structure.

L1 Response:

These concerns have been addressed in our responses to W1 and Q2. We added controlled ablations comparing No Doppler, Global Doppler, and the proposed Localized Doppler on all three datasets. The results consistently support the contribution of the localized Doppler mechanism. We also repeated RadarFlowPose with multiple independent training seeds and now report the mean ±\pm standard deviation on all three datasets. The small standard deviations indicate stable performance across independent runs.

L2 Response:

As discussed in Q3, Flow refinement provides more consistent improvements in articulated structure and motion consistency than in absolute MPJPE or bone-length error. We have clarified this performance profile in the revised manuscript.

Reviewer uUw5OpenReview ↗
Rating
3/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
2/4
Originality
2/4
Contribution type
use_inspired
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper proposes RadarFlowPose, a coarse-to-fine framework for 3D human pose estimation using millimeter-wave radar point clouds.

The authors evaluate MPJPE and PA-MPJPE on three radar pose datasets: mmBody, MM-Fi, and Reb3D. The results demonstrate that RadarFlowPose achieves state-of-the-art or near-state-of-the-art performance across various settings; notably, the improvements in PA-MPJPE are more consistent, indicating a significant enhancement in the structural consistency of the estimated poses. Additionally, the authors present analyses regarding the coarse module, joint/bone-level performance, initialization strategies, and robustness to occlusion.

Strengths and weaknesses

Strengths.

  1. Millimeter-wave radar holds great potential for applications in human-computer interaction, privacy protection, low-light environments, and health monitoring. Performing 3D pose estimation using radar point clouds is a task that is both significant and challenging.
  2. Instead of treating radar data merely as ordinary point clouds, the paper leverages Doppler information to perform motion-aware refinement. This approach aligns more effectively with the characteristics of the millimeter-wave radar modality.

Weaknesses.

  1. There are existing precedents for coarse-to-fine strategies, kinematic priors, Transformer decoders, localized radar attention, Doppler aggregation, and diffusion/flow-based refinement. The paper's primary novelty lies in combining these elements for radar skeleton refinement, rather than proposing a brand-new Flow Matching theory or a novel radar representation.
  2. The authors compared random initialization versus coarse initialization but did not adequately compare approaches such as "identical coarse prior + deterministic residual regression" or "identical coarse prior + iterative MLP/Transformer refinement." If simple residual regression could achieve comparable results, the core contribution of Flow Matching would be diminished.
  3. The paper compares methods such as PointTransformer, P4DTransformer, DiffPose, and mmDiff, but fails to provide a comprehensive comparison of results—based on unified implementations—for radar-based pose estimation methods like HuPR, TransHuPR, mmGAT, and mmPose-FK on the corresponding datasets. While these methods are mentioned in the "Related Work" section, they are not systematically compared in the experimental tables.
  4. The paper states that inference derives the final pose through integration via Euler updates; however, the main text does not clearly specify the default number of refinement steps, the impact of varying step counts on accuracy and speed, whether randomness is involved, or whether averaging across multiple samples is performed. Such details regarding the Flow Matching method significantly influence the results and reproducibility.
Questions
  1. Please include a key ablation study: use the same coarse pose generator and the same Doppler/local attention/structure decoder, but omit Flow Matching in favor of directly predicting the residual offset or performing single-step/multi-step deterministic refinement. This experiment will determine whether the performance gains stem from the Flow Matching training objective or from the combination of the coarse prior and the Doppler-aware residual decoder. If residual regression yields results comparable to RadarFlowPose, I would lower my assessment of the method's core contribution; conversely, if Flow Matching proves significantly superior, I would raise the score.
  2. Current methods integrate the velocity field using Euler updates; however, the main paper does not explicitly specify the default number of steps, inference time per frame or sequence, parameter count, VRAM usage, FLOPs, or the trade-off between step count and accuracy. It is recommended to include an ablation study on the number of steps and a latency table in the rebuttal. If the model is significantly slower than mmDiff/DiffPose or direct regression methods, its deployability in practical radar sensing scenarios should be addressed.
  3. For instance, DiffPose achieves a lower average MPJPE on mmBody, and in certain MM-Fi configurations, the MPJPE of SRL+LTA+KPC is lower than that of the full model. Please clarify whether flow refinement primarily optimizes PA-MPJPE or velocity at the expense of absolute position accuracy. It is recommended that the authors distinguish between "structural plausibility" and "absolute localization accuracy" in their claims.
  4. Please clarify whether PointTransformer, P4DTransformer, DiffPose, mmDiff, and TDR+STE were retrained by the authors using a unified approach, and whether identical radar points, stacked frames, Doppler/SNR information, and evaluation protocols were employed. If certain baseline figures are sourced from original papers or rely on differing implementation settings, the credibility of the comparative results in the table will be compromised.
  5. Related work mentions methods such as HuPR, TransHuPR, mmGAT, and mmPose-FK, yet the experimental tables lack a systematic comparison with them. If these methods cannot be directly adapted to all datasets, please include a comparison on at least one public dataset or explain why a comparison is not feasible.
Limitations

See Weakness.

Final justification

I appreciate the authors' detailed response, which addressed my initial concerns regarding reproducibility and experimental clarity. Specifically, the authors clarified the deterministic inference process, default Euler steps, unified re-implementation of baselines, and the trade-off between efficiency and accuracy. The newly added Direct-RR experiment is also valuable, demonstrating that a simple single-step residual predictor cannot match the performance of RadarFlowPose. Consequently, I have reduced the weight given to my previous concerns regarding missing implementation details, baseline comparability, and practical deployment issues.

After re-evaluating the paper as a "General contribution," my primary concerns remain regarding the methodological originality, the demonstrated generality, and the extent to which the experiments isolate the specific contribution of Flow Matching. Direct-RR is a relatively limited single-step baseline that performs worse than even the coarse estimator. While this reveals the limitations of unconstrained single-step correction, it does not conclusively prove that the performance gain stems specifically from Flow Matching rather than from the iterative, state-dependent refinement process that incorporates repeated Doppler re-aggregation. To support this claim, a more robust comparison is needed against "multi-step deterministic refinement" or "recurrent refinement" methods that utilize the same backbone, intermediate states, and conditioning information.

Furthermore, the performance gains are most consistent in terms of PA-MPJPE, whereas improvements in absolute MPJPE are less stable. Thus, the evidence primarily supports the method's ability to improve aligned skeletal structure rather than achieving universal gains in absolute 3D pose localization. Although the evaluation across three datasets is valuable, all experiments are confined to the relatively narrow scenario of "supervised radar-to-skeleton estimation," and the paper fails to demonstrate broader applicability beyond this task. While the response has technically strengthened the submission, I still feel that the originality, generality, and significance of the contribution fall short of the acceptance threshold.

Therefore, I agree to raise my score by one point but maintain a negative recommendation, primarily due to the aforementioned methodological issues rather than application-level or deployment-related considerations.

Formatting concerns

The authors' supplementary material still mentions CVPR 2026; if this is a resubmission, please remove all references to the previous submission.

1 comment
Authors · RebuttalOpenReview ↗
Rebuttal

We sincerely appreciate the reviewer's careful reading and valuable suggestions. The questions have helped us better clarify the motivation behind our design, explain the key technical contributions more explicitly, and further improve the presentation of the paper.

W1 Response:

The methodological contribution of RadarFlowPose lies in how these elements are coupled for radar pose refinement, rather than in treating them as independent modules. Specifically, we formulate pose refinement as a coarse-anchored conditional transport process, in which a structurally plausible coarse pose serves as the transport source, localized Doppler evidence is re-aggregated around the evolving joint positions, and a topology-constrained decoder predicts state-dependent refinement velocities. The evolving pose therefore directly determines the radar evidence used at the next refinement step, creating a closed-loop interaction among the pose state, localized motion cues, and the Flow-Matching velocity field.

W2 Response:

We thank the reviewer for this valuable suggestion. To isolate the contribution of Flow Matching, we constructed a controlled baseline termed One-step Direct Residual Refinement (Direct-RR). Direct-RR uses exactly the same pretrained and frozen coarse-pose estimator, radar conditioning, localized Doppler representation, and Transformer-based refinement backbone as RadarFlowPose. However, it directly predicts the full pose residual through a single deterministic update, without intermediate-state sampling, Flow-Matching supervision, or Euler integration.

Method mmBody MPJPE ↓ mmBody PA-MPJPE ↓ MM-Fi MPJPE ↓ MM-Fi PA-MPJPE ↓ ReB3D MPJPE ↓ ReB3D PA-MPJPE ↓
Coarse 75.01$\pm$ 0.18 59.54$\pm$ 0.09 62.26$\pm$ 0.22 52.27$\pm$ 0.21 64.91$\pm$ 0.42 54.76$\pm$ 0.23
Direct-RR 86.29$\pm$ 0.28 65.71$\pm$ 0.26 69.86$\pm$ 0.57 54.10$\pm$ 0.25 65.31$\pm$ 0.62 56.21$\pm$ 0.51
RadarFlowPose 74.37 ±\pm 0.33 55.71 ±\pm 0.21 66.09 ±\pm 0.36 50.47 ±\pm 0.17 64.29 ±\pm 0.23 53.97 ±\pm 0.35

Direct-RR underperforms both the coarse estimator and RadarFlowPose across all six evaluation metrics. In particular, compared with RadarFlowPose, Direct-RR increases PA-MPJPE from 55.71 to 65.71 on mmBody, from 50.47 to 54.10 on MM-Fi, and from 53.97 to 56.21 on ReB3D.

Qualitative inspection further suggests that Direct-RR tends to over-correct joints that are already reasonably estimated by the coarse stage. On mmBody, for example, it introduces noticeable errors in the predicted thigh lengths, despite these regions being relatively accurate in the coarse pose. In contrast, Flow Matching learns state-dependent velocity fields and progressively updates the pose through intermediate states. This enables more gradual and spatially localized corrections, reducing the risk of unnecessarily modifying the entire skeleton in a single step.

We will include this ablation in the revised manuscript, together with qualitative comparisons similar to those presented in Fig. 3.

W3 Response:

Thank you for raising this concern. We selected baselines that operate on radar point clouds and have executable public implementations, allowing them to be evaluated under the same protocol. All reported methods use the same dataset splits, data loader, point-cloud preprocessing, skeleton annotations, radar samples, number of points per frame, temporal window, and MPJPE/PA-MPJPE evaluation metrics. Batch size is adjusted only to accommodate differences in architecture and memory usage. We will clarify these details in the revised manuscript.

HuPR and TransHuPR use a different two-radar 2D pose-estimation setting. For mmGAT and mmPose-FK, complete executable implementations are not publicly available. Independently reimplementing these methods could introduce implementation bias, while directly quoting their published results would mix different datasets and evaluation protocols. We therefore discuss them in the Related Work section but do not include them in the unified quantitative comparison.

W4 Response:

We have clarified the distinction between training and inference in the main paper. During training, a small Gaussian perturbation with a standard deviation of 0.01 is added to the intermediate pose states, helping the velocity network learn corrections in the neighbourhood of the refinement trajectory.

At inference, the model starts from the unperturbed Stage-1 coarse pose and follows a single deterministic trajectory. No noise, random initialization, repeated sampling, best-of-NN selection, or prediction averaging is used. Two Euler steps are used by default. At each step, the decoder predicts a three-dimensional flow vector for each joint in pose space, which is used to update the current pose. The localized Doppler features are then recomputed around the updated joint locations before the next step.

The effect of the Euler step count was evaluated in Fig. 10 of the supplementary material. Accuracy remains broadly stable across the tested step counts, while runtime increases approximately linearly, as reported in Table 5. We have now referenced this analysis in the main paper and explicitly stated that two Euler steps are used in all reported experiments.

Q1 Response:

This point has been addressed in detail in our response to W1. The Direct-RR ablation shows that Flow Matching clearly outperforms one-step direct residual refinement. Please refer to W1 for the full results and accompanying analysis.

Q2 Response:

Thank you for this suggestion. We have clarified the default inference setting and added the step-count accuracy–efficiency analysis and latency comparison to the supplementary material. Figure 10 shows that accuracy remains broadly stable across different Euler step counts, while runtime increases approximately linearly, as reported in Table 5. We therefore use two Euler steps by default for all main accuracy results.

Under the same NVIDIA A40 GPU setting, using the same four 297-frame MM-Fi sequences, RadarFlowPose achieves substantially lower inference latency than mmDiff at both evaluated step counts. It is approximately 25.5 times faster with one step and 6.5 times faster with 20 steps. The runtime of RadarFlowPose increases approximately linearly with the number of Euler steps, with each additional step adding about 66.6 ms per sequence, compared with approximately 351.2 ms for mmDiff. RadarFlowPose therefore remains substantially faster even when more refinement steps are used.

For mmDiff, GFLOPs increase only slightly with the number of steps, whereas runtime increases substantially, suggesting that its iterative process introduces considerable execution overhead. In RadarFlowPose, each step re-evaluates the velocity-field network, so its FLOPs increase more noticeably. Nevertheless, its sequence-level parallel processing results in substantially lower actual inference latency. RadarFlowPose uses more GPU memory because it processes the full sequence simultaneously, whereas mmDiff produces poses frame by frame. This higher memory consumption is therefore exchanged for much lower sequence-level latency.

Method Steps Params (M) GFLOPs Time/Sequence (ms) ↓ FPS ↑ VRAM (GB)
mmDiff 1 25.867 6787.57 2033.56 146.05 0.9100
RadarFlowPose 1 28.720 2054.99 79.77 3723.16 2.7929
mmDiff 20 25.867 6950.30 8706.83 34.11 0.9100
RadarFlowPose 20 28.720 37843.71 1345.75 220.70 2.7931

Q3 Response:

As discussed in the original manuscript on Pages 7–8, the coarse stage primarily determines the global pose location, whereas the Flow-Matching stage refines the relative skeletal configuration around this initialization. We agree that this distinction was not sufficiently prominent.

The refinement stage is not designed to trade absolute localization accuracy for improved PA-MPJPE or velocity estimation. Rather, its improvements are more consistently reflected in PA-MPJPE because MPJPE remains sensitive to global translation and orientation errors inherited from the coarse estimate. We have revised the manuscript to distinguish more clearly between structural pose refinement and absolute localization accuracy.

Q4 Response:

PointTransformer, P4DTransformer, DiffPose, mmDiff and TDR+STE were all reimplemented by us under a unified protocol. They use the same dataset splits, data loader, point-cloud preprocessing, radar samples and number of points per frame.

Methods requiring temporal input use the same number of stacked frames. Spatial coordinates, Doppler, and SNR are generated through the same preprocessing pipeline, while the tensor layout follows the original input format of each architecture. Frame-based methods are evaluated frame by frame rather than being artificially converted into sequence models, whereas sequence-based methods use the same sequence length. Batch size is adjusted only to accommodate differences in architecture and memory usage.

We have clarified in the revised manuscript that all reported results were obtained through our own unified reimplementation, training, and evaluation protocol.

Q5 Response:

This point has also been addressed in our response to W3. Please refer to the accompanying analysis above.

RC Response:

Thank you for pointing this out. This is the first submission of the paper. “CVPR 2026” was inadvertently retained in the supplementary filename from the official template. We will correct the filename in the revised submission.

Reviewer cRsROpenReview ↗
Rating
4/6
Confidence
4/5
Quality
2/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The authors present RadarFlowPose, a radar pose detection algorithm that uses a coarse-to-fine flow-based refinement procedure while leveraging doppler, joint, structure, time, and velocity embeddings. The method leverages vision based coarse to fine refinement and biomechanics focused modeling of joints as a tree structure that has length and direction. The authors provide a detailed problem formulation and mathematical model. The quantitative analysis shows evidence of measurable improvements in PA-MPJPE over existing methods as well as slight overall improvement of the MPJPE on three different datasets.

Strengths and weaknesses

Strengths:

  • The overall concept that is detailed in the article is novel and a well thought-out progression of current state-of-the-art methods combined with computer vision style techniques. Coarse-to-fine refinement with Doppler, Joint, Structure, velocity, and time constraints is validated by the measurable and consistent improvements in PA-MPJPE.
  • While RadarFlowPose errors are still ~1.5-2x larger than existing under constrained 2D vision methods and 3-4x larger than properly constrained video 3D methods, the proposed method improves upon the current state-of-the-art in radar-based pose estimation with a MPJPE of ~70mm and a PA-MPJPE of ~50mm.
  • Encoding of radar points into a structured latent space which is then matched temporally into latent trajectories that are constrained by a kinematic prior for coarse pose generation includes the biomechanical a priori knowledge and need for temporal consistency that is needed to physically plausible and consistent initializations for the refinement step.
  • Figure 4 is a dense description of the qualitative errors but is well assembled and space efficient.

Weaknesses:

  • There is a lack of detail about the Decoder step of the overall architecture. How does the key/value query of pose and embedding information get transformed into a dense pose representation. The architecture of the decoder should be included in the main paper. There is little information included about the FFN, self attention, and cross attention network architectures.
  • Section 4.2 should be the beginning of the results and analysis section.
  • Tables 1 & 4 should have the same organization as Tables 2-3 where the MPJPE and PA-MPJPE are grouped columns. Inconsistency is difficult to follow and multiple highlighted (bold & underlined) values is difficult to compare across methods.
  • Figure 3 is meaningless without the skeleton defining each joints location (Figure 5). Also the text is too small to read even when zoomed in to the graphic. The inconsistency of the skeleton labeling makes it difficult to compare across models. Can these be combined into a common set with variations for each method. (Think Venn diagram of skeleton joint locations).
  • The coarse estimate has an ablation study but the refinement network does not. How can the reader be convinced that the Vision-Inspired flow matching is actually making the difference?
Questions
  1. Can the missing details of the refinement decoder in Figure 1 be outlined/added to the main paper and/or supplemental materials?
  2. Why are the errors in Figure 3 so much higher for joints J18-J21 as compared to all other joints? Is there consistent behavior for other datasets? It is expected that velocity error should increase relative to the distance that each joint is from the origin in the tree structure. Why is error not cumulative?
  3. Expectation would be that random and coarse errors in Table 4 should be much further apart. Why is random initialization so close to coarse initialization?
  4. How can it be clearer that the proposed method outperforms existing method on existing datasets? Unifying the format of Tables 1-4 will clearly show the proposed method as the best choice and clearly the new SOTA. Table 1 is not a convincing argument that RadarFlowPose is the new SOTA. Consider separating the ablation results as a independent table to make the results easier to follow for each section of the article.
  5. Can the ablation study be inclusive the refinement components?
Limitations

The limitations are not clearly discussed nor is there a specific section intended to discuss limitations. There is a discussion of occlusions in the supplemental. Maybe that should be discussed in the main article.

Final justification

The rebuttals provided by the author(s) addressed most of the Weaknesses, Questions, and Limitations that the reviewers and area chair have identified. Most of the responses were thorough but occasionally left/created gaps/inconsistencies when addressing the initial concerns of the reviewers. The global doppler impact is a clear and convincing novel contribution to the architecture and method based on quantitative results provided in the rebuttal. While this reviewers primary concerns have been addressed in the responses and the article with expected changes has improved, the key quantitative results are still not a fully convincing argument that the novel contributions of the method presented will consistently outperform the SOTA methods. (1) Direct-RR is mostly worse than Coarse making it less convincing. (2) The memory vs latency tradeoff is just that, a tradeoff not a savings.

While this article has improved and has potential, I am not compelled to change my rating, maintaining a borderline accept while increasing my confidence in that rating.

Formatting concerns

Paper appears well formatted.

1 comment
Authors · RebuttalOpenReview ↗
Rebuttal

We sincerely appreciate the reviewer's insightful comments and valuable suggestions. They have helped us clarify several important aspects of the paper, improve the presentation of our motivation and contributions, and further strengthen the manuscript by motivating an important additional experiment.

W1 Response:

We have expanded Section 3.3 to describe the decoder architecture and data flow. The radar point cloud is first linearly projected into a BT×N×512BT \times N \times 512 memory sequence, which provides the keys and values for cross-attention. For each joint, the query token consists of five parts, as shown in Fig. 1.

The refiner consists of six pre-normalized Transformer decoder layers, with an embedding dimension of 512, eight attention heads, and an FFN dimension of 2048. In each layer, joint self-attention is constrained by the kinematic tree, allowing each joint to attend only to itself, its parent, and its direct children. Cross-attention is spatially localized: each joint attends only to radar points within a joint-dependent neighbourhood around its current position. The base radius is 0.1 m, scaled to 0.06 m for core joints and 0.15 m for end-effectors. If no radar point lies within the neighbourhood, the nearest point is retained.

The final decoder features have a shape of BT×J×512BT \times J \times 512 and are projected by a shared linear head into a three-dimensional velocity vector for each joint. The decoder therefore does not directly regress the final dense pose in a single pass. Instead, the velocity field is integrated from the coarse pose to produce the final pose.

W2 Response:

We have reorganized the manuscript so that the original Section 4.2 now begins a separate “Results and Analysis” section.

W3 Response:

We have reorganized Tables 1 and 4 to follow the same format as Tables 2 and 3 and simplified the highlighting to make comparisons across methods clearer.

W4 Response:

We have placed each dataset’s skeleton definition alongside its corresponding figure to improve readability and facilitate comparison.

W5 Response:

We thank the reviewer for this valuable suggestion. To isolate the contribution of Flow Matching, we constructed a controlled baseline termed One-step Direct Residual Refinement (Direct-RR). Direct-RR uses exactly the same frozen coarse-pose estimator, radar conditioning, localized Doppler representation, and Transformer-based refinement backbone as RadarFlowPose. However, it directly predicts the full pose residual through a single deterministic update, without intermediate-state sampling, Flow-Matching supervision, or Euler integration.

Method mmBody MPJPE ↓ mmBody PA-MPJPE ↓ MM-Fi MPJPE ↓ MM-Fi PA-MPJPE ↓ ReB3D MPJPE ↓ ReB3D PA-MPJPE ↓
Coarse 75.01$\pm$ 0.18 59.54$\pm$ 0.09 62.26$\pm$ 0.22 52.27$\pm$ 0.21 64.91$\pm$ 0.42 54.76$\pm$ 0.23
Direct-RR 86.29$\pm$ 0.28 65.71$\pm$ 0.26 69.86$\pm$ 0.57 54.10$\pm$ 0.25 65.31$\pm$ 0.62 56.21$\pm$ 0.51
RadarFlowPose 74.37 ±\pm 0.33 55.71 ±\pm 0.21 66.09 ±\pm 0.36 50.47 ±\pm 0.17 64.29 ±\pm 0.23 53.97 ±\pm 0.35

Direct-RR underperforms both the coarse estimator and RadarFlowPose across all six evaluation metrics. In particular, compared with RadarFlowPose, Direct-RR increases PA-MPJPE from 55.71 to 65.71 on mmBody, from 50.47 to 54.10 on MM-Fi, and from 53.97 to 56.21 on ReB3D.

Qualitative inspection further suggests that Direct-RR tends to over-correct joints that are already reasonably estimated by the coarse stage. On mmBody, for example, it introduces noticeable errors in the predicted thigh lengths, despite these regions being relatively accurate in the coarse pose. In contrast, Flow Matching learns state-dependent velocity fields and progressively updates the pose through intermediate states. This enables more gradual and spatially localized corrections, reducing the risk of unnecessarily modifying the entire skeleton in a single step.

We will include this ablation in the revised manuscript, together with qualitative comparisons similar to those presented in Fig. 3.

Q1 Response:

This point is also raised in W1. Please refer to our response there for further details.

Q2 Response:

J18–J21 correspond to distal arm joints, especially the wrists and hands. Their radar returns are less stable than those of the torso because of their smaller reflecting areas, faster motion, intermittent visibility, and ghost points caused by sparse and discontinuous observations. We observed the same qualitative tendency on the other datasets, although the exact joint indices differ according to their skeleton definitions.

The error does not necessarily accumulate with distance from the root because the refinement stage does not recover joints sequentially along the kinematic tree. Instead, all joint velocities are predicted jointly and in parallel using topology-constrained self-attention. The flow refiner then applies small, state-dependent corrections over multiple steps. When the local radar evidence is weak, these corrections remain limited rather than being recursively propagated through the entire chain, thereby avoiding systematic error accumulation.

Q3 Response:

The random-initialization setting is not unconditional. The coarse pose remains a strong condition, together with the radar features, skeleton topology, and localized Doppler cues. Without sufficiently informative conditioning, ambiguous radar observations can cause an MSE-trained velocity field to average over different plausible correction directions. This experiment was designed to test whether Flow Matching can start from a random source, extract the structural guidance provided by the coarse pose, and recover the target pose. The results show that it can. Using the coarse pose directly as the source further shortens the transport path and allows the model to focus on local refinement, resulting in a consistent but moderate improvement.

Q4 Response:

Thank you for the suggestion. We have standardized Tables 1–4 and separated the main comparisons from the ablation results in the revised manuscript.

Q5 Response:

This point has been addressed in detail in our response to W5. Please refer to the Direct-RR ablation and the accompanying analysis above.

L1 Response:

Thank you for pointing this out. The original manuscript includes a brief limitations paragraph, but we agree that the limitations should be stated more clearly. We will expand this discussion and move the key analysis of occlusion from the supplementary material to the main paper.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Missing a submission?

Loading the discussion…