AVI-HT: Adaptive Vision-IMU Fusion for 3D Gloved Hand Tracking
Ziyi Kou, Ankit Kumar, Mia Huang, Taylor Niehues, Vatsal Mehta, Ergys Ristani, Li Guan
TL;DR. A vision-IMU fusion method that adaptively combines egocentric images and on-glove IMU signals to track 3D hand poses through heavy occlusion.
Abstract. We present AVI-HT, an adaptive visual-IMU fusion approach for tracking 3D hand poses by jointly modeling the egocentric images with on-glove 6-DoF IMU signals. AVI-HT significantly improved accuracy and availability, particularly in hand-object interaction (HOI) scenarios involving heavy visual occlusion. Two complementary ingredients underpin its success: (1) synchronized multi-modal training data pairing on-body vision-IMU sensor streams with ground-truth 3D hand poses from a motion-capture system, and (2) a cross-sensor deep attention mechanism that adaptively modulates the trust assigned to the vision and individual IMU sensors. To evaluate AVI-HT in real-world settings, we conduct extensive experiments on our DexGloveHOI dataset that consists of 100K+ pairwise vision-IMU samples with synchronized 3D annotated poses, in which users manipulate a variety of objects during daily tasks. We compare against multiple single- and multi-modal tracking approaches under two hand models (UmeTrack, MANO). The results show that AVI-HT reduces mean keypoint error by 16.1% and its wrist-aligned variant by 24.2% over the baselines. A hand-object contact evaluation shows that AVI-HT keeps finger contacts with the manipulated object more accurately and consistently over time, reducing contact losses by 8.5%. Ablation studies further show that our fusion design outperforms simpler schemes and that the gains grow with occlusion and hold across subjects.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 5 reviews · OpenReview
Updated 25 Nov 2026, 03:43 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
Summary: proposes a practical vision-IMU fusion approach for 3D hand tracking during severe occlusion, together with a novel synchronized dataset (DexGloveHOI).
Strengths: Two important contributions: addressing visual occlusion in hand-object interaction using a complementary multimodal approach; the newly collected DexGloveHOI dataset, featuring MoCap supervision and extensive sensor-level analysis.
Weaknesses: concerns regarding limited subject diversity, unclear evaluation protocols, and a lack of rigorous baseline comparisons against multimodal fusion approaches.
Decision: Accept - all 4 reviews are accept leaning and many of the weaknesses raised with comprehensively discussed during the rebuttal.
Final justification
See above.
- Final justification
- See above.
Read meta-review
Meta-review
Summary: proposes a practical vision-IMU fusion approach for 3D hand tracking during severe occlusion, together with a novel synchronized dataset (DexGloveHOI).
Strengths: Two important contributions: addressing visual occlusion in hand-object interaction using a complementary multimodal approach; the newly collected DexGloveHOI dataset, featuring MoCap supervision and extensive sensor-level analysis.
Weaknesses: concerns regarding limited subject diversity, unclear evaluation protocols, and a lack of rigorous baseline comparisons against multimodal fusion approaches.
Decision: Accept - all 4 reviews are accept leaning and many of the weaknesses raised with comprehensively discussed during the rebuttal.
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 2/4
- Clarity
- 2/4
- Significance
- 3/4
- Originality
- 2/4
- Contribution type
- use_inspired
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper proposes combining two modalities, egocentric vision and hand-mounted IMUs, to infer hand pose. The authors develop a data-collection platform for acquiring synchronized IMU and egocentric vision signals, along with ground-truth hand-pose labels. This platform is used to collect a dataset with both IMU and egocentric images, DexGloveHOI. The authors then propose a transformer-based multimodal model that fuses IMU data and egocentric images to estimate hand pose.
This joint approach is experimentally shown to improve hand pose tracking performance compared to a purely visual approach, since IMU signals provide additional pose information when the hand is occluded from the camera. The authors also propose additional architectural contributions that help improve performance.
Strengths and weaknesses
Strengths:
- The authors correctly identify a gap with current SoTa approaches to hand pose estimation that use egocentric visual inputs. Visual approaches fail when the hand is occluded from the camera, a common scenario during hand-object manipulation.
- They build a data collection platform for getting synchronized IMU and egocentric images along with ground truth pose labels to collect a dataset with both modalities.
- The authors propose a multimodal fusion algorithm that outperforms SoTa vision-only hand pose estimation algorithms. This algorithm is trained with their collected dataset.
Weaknesses:
- Although the authors show experimentally that combining IMU and egocentric vision improves hand pose estimation performance, the "adaptive" nature of the algorithm isn't substantiated (See questions).
- The architectural contributions of the algorithm are not justified either theoretically or empirically.
Questions
Main questions:
- Can the authors provide a stronger justification for their algorithmic contributions either theoretically or through an ablation study? The "Hierarchical cross-sensor attention" contribution isn't particularly convincing.
- Can there be a more thorough ablation study with respect to the number and placement of the IMUs? Figure 4 is useful but, in my opinion, insufficient.
Some clarifications:
- The authors claim in Line 167, "When a hand joint is visually occluded, its attention weight shifts toward the spatially corresponding IMU sensor, which provides adaptive, occlusion-aware fusion that is anatomically grounded by the kinematic prior". This claim isn't substantiated anywhere in the paper.
- Can the gravity vector extraction be explained? Does it work during fast hand movement, where the motion acceleration contaminates the gravity vector from the accelerometer?
- Can the IMU placement and data tensor be explained better ("On-glove IMU signals" from Line 126)?
Minor clarifications and typos:
- Line 192: "such as such as " -> such as repeated twice
- Line 164 - Formula for has an incorrect comma.
Limitations
The authors are upfront about one limitation faced by the SoTa visual baseline, HaMer, that the mesh of the hand being tracked is occluded by the motion capture glove. It would be useful to see if fine-tuning Hamer with their newly captured dataset improves performance.
Final justification
In light of the detailed rebuttal, I upgrade my score from 3 to 4.
The ablation study of the author's proposed architecture is especially appreciated, since it further justifies their algorithmic contribution.
Unfortunately, since the authors submitted this paper in the General track instead of the Use-Inspired track, I lowered my originality score from 3->2.
Formatting concerns
None
5 comments
Dear Reviewer WnMa,
Thanks again for your feedback. We wanted to gently follow up on our rebuttal, where we addressed your comments. We'd be glad to hear any further thoughts or answer any remaining questions.
Dear Reviewer WnMa,
Thank you for your review again. As the discussion deadline approaches, we want to kindly follow up on our rebuttal, which we hope has addressed your concerns. We'd be glad to clarify anything further, and hope you'll consider our responses when finalizing your assessment.
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 2/4
- Originality
- 2/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper presents AVI-HT, a vision-IMU fusion framework for 3D hand tracking in egocentric hand-object interaction. The method combines egocentric images with 12 on-glove 6-DoF IMU sensors and uses a hierarchical cross-sensor attention mechanism to adaptively fuse visual and inertial features. The authors also collect DexGloveHOI, a synchronized vision-IMU-MoCap dataset, and evaluate the method under both UMETrack and MANO hand representations. The results show improved tracking accuracy over vision-only, IMU-only, and EKF-based baselines, especially under occlusion.
Strengths and weaknesses
[Strengths]
The paper studies an important practical problem: egocentric hand tracking during object interaction, where vision-only methods often fail due to severe occlusion. The proposed system is well motivated, and the combination of egocentric vision, on-glove IMUs, and MoCap supervision is useful for studying multimodal hand tracking. The paper is also reasonably complete experimentally, with evaluations under two hand representations, per-joint analysis, sensor contribution analysis, and sensitivity studies for IMU noise and temporal misalignment.
[Weaknesses]
- The contribution of the proposed fusion architecture is not sufficiently isolated. Since hand-object interaction naturally causes severe visual occlusion, it is expected that adding 12 on-glove IMU sensors improves over vision-only tracking. However, the paper lacks strong learned multimodal fusion baselines, such as early feature concatenation, late fusion, pooled IMU-token fusion, or transformer fusion without the proposed kinematic prior and hierarchical attention. As a result, it is unclear whether the gains come from the proposed adaptive fusion design or simply from the additional IMU hardware.
- The comparison to vision-only baselines may be biased by the sensing glove. The data sensing glove changes the visual appearance of the hand. Vision-only baselines may therefore be disadvantaged when evaluated on gloved-hand images, while AVI-HT benefits from the glove-mounted IMUs. This makes it difficult to assess how much of the improvement reflects better multimodal fusion versus a domain shift that hurts vision-only methods.
- The dataset has limited subject diversity. Although DexGloveHOI contains over 100K frames, it is collected from only four participants. For hand tracking, generalization across hand shapes, wearing styles, sensor placement, and manipulation habits is important. The paper would be stronger with broader participant diversity and clearer cross-subject evaluation.
Questions
- Can the authors provide comparisons against simple but strong learned multimodal fusion baselines, such as early feature concatenation, late fusion, pooled IMU-token fusion, or transformer fusion without the kinematic prior mask?
- Are the vision-only baselines fine-tuned on the same gloved-hand DexGloveHOI training data? If so, how much does the glove appearance degrade their performance compared with bare-hand inputs?
- How sensitive is AVI-HT to changes in glove placement, calibration quality, or sensor layout across users?
Limitations
The main limitation is that the method requires a specialized glove with 12 IMU sensors, which changes both the sensing setup and the visual input distribution. The evaluation also appears limited in participant diversity. More importantly, without stronger learned multimodal baselines, it remains unclear whether the proposed adaptive attention architecture is the key contributor, rather than the additional IMU hardware itself.
Final justification
The rebuttal resolved my main concern: new fusion baselines show the gains come from the adaptive attention design, not merely added IMU hardware, and the occlusion-binned results confirm improvements concentrate where vision fails. The training protocol clarification addresses the glove-bias issue. Limited subject diversity and the undocumented ~8M training set remain, but these are scope limitations, not validity flaws. I raise my score from 3 to 4.
Formatting concerns
N/A
3 comments
We thank the reviewer for the valuable suggestions and address each question below.
Q1. Comparisons against strong learned fusion baselines. We have implemented all of the requested variants.
- Early concat: no attention; vision and IMU backbone features are concatenated and linearly projected.
- Late fusion: a separate IMU pose decoder; only the predicted joint angles from the vision and IMU branches are fused at the output.
- Pooled IMU token: average-pool all IMU tokens instead of taking the last token after the transformer.
- Fusion-1 only: remove the second-level self-attention.
- w/o k-prior: remove the kinematic-prior mask from the first-level attention.
| Model | MKPE | F.MKPE | MKPE.T | F.MKPE.T | P.A | P.A.T |
|---|---|---|---|---|---|---|
| UMETrack | 12.342 | 17.478 | 9.359 | 17.798 | 76.059 | 81.433 |
| AVI-HT (early concat) | 11.928 | 16.935 | 8.649 | 16.545 | 76.208 | 82.629 |
| AVI-HT (late fusion) | 12.139 | 16.492 | 7.054 | 13.233 | 75.818 | 85.825 |
| AVI-HT (pooled IMU token) | 11.956 | 14.571 | 7.940 | 14.427 | 76.213 | 84.027 |
| AVI-HT (fusion-1 only) | 11.113 | 14.088 | 7.456 | 13.740 | 77.818 | 84.994 |
| AVI-HT (w/o k-prior) | 10.901 | 13.898 | 7.406 | 13.611 | 78.238 | 85.090 |
| AVI-HT (full) | 10.359 | 13.253 | 7.021 | 12.785 | 79.315 | 85.859 |
We observe that all of these baselines trail the full model, and the naive baselines do so by a wide margin. The reason is that IMU calibration and synchronization noise is non-negligible, so unconditional fusion degrades the fully-visible case in which vision alone already suffices. The attention design instead raises the IMU weight only when its occlusion-driven benefit outweighs that noise, which is what delivers the consistent gains.
Q2. Are the vision-only baselines fine-tuned on the same gloved-hand DexGloveHOI training data? How much does glove appearance degrade them vs. bare hands?
Firstly we would like to clarify that all baselines and AVI-HT are trained on the same separate large-scale (~8 million) glove-manipulation training set and DexGloveHOI is used only for evaluation. They therefore serve exactly as the identical-backbone baselines requested, which isolates the contribution of the IMU fusion.
However, isolating the effect of glove appearance alone is not a defined problem in our setting. Fine-tuning adapts the model jointly to the glove appearance and to the dataset's objects, interactions, and cameras, so a bare-hand comparison would conflate all of these factors and could not cleanly attribute any change to the glove itself. We would also gently note that bare-hand input is not an operating point of AVI-HT. Since the IMUs are mounted on the glove, glove-vision together with on-glove IMU constitutes a single sensing modality, and a bare-hand configuration is undefined for the fused system.
Q3. Sensitivity to glove placement, calibration quality, and sensor layout across users.
In terms of sensitivity to glove placement, calibration, and layout, Figure 7 of our paper reports two relevant studies: on IMU signal noise and on CV–IMU temporal misalignment,. The results show measurable but bounded sensitivity, with the IMU-side perturbations having the larger effect. Regarding user-level variability specifically, the per-subject results below show consistent gains with only small variance across all four participants, which indicates that the improvement stems from the CV–IMU fusion itself rather than from over-fitting to any single subject's glove placement or sensor layout.
| Participant | MKPE | F.MKPE | MKPE.T | F.MKPE.T | P.A | P.A.T |
|---|---|---|---|---|---|---|
| Subject 1 | 10.847 | 13.841 | 7.069 | 12.792 | 78.324 | 85.762 |
| Subject 2 | 9.624 | 12.190 | 6.548 | 12.469 | 80.797 | 86.811 |
| Subject 3 | 11.266 | 14.448 | 7.722 | 13.814 | 77.486 | 84.450 |
| Subject 4 | 8.852 | 11.512 | 6.266 | 11.311 | 82.333 | 87.371 |
Dear Reviewer FMLP,
Thanks again for your feedback. We wanted to gently follow up on our rebuttal, where we addressed your comments. We'd be glad to hear any further thoughts or answer any remaining questions.
Dear Reviewer FMLP,
Thank you for your review again. As the discussion deadline approaches, we want to kindly follow up on our rebuttal, which we hope has addressed your concerns. We'd be glad to clarify anything further, and hope you'll consider our responses when finalizing your assessment.
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 2/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
AVI-HT is a multimodal framework for 3D hand tracking that combines egocentric images with signals from 12 on-glove 6-DoF IMUs. It is designed for hand-object interaction scenarios in which fingers are frequently occluded and vision-only tracking becomes unreliable. The method encodes visual and temporal IMU features separately and then fuses them through a hierarchical cross-sensor attention module guided by the hand’s kinematic structure. This enables the model to rely more heavily on relevant IMUs when visual evidence is weak, while still using vision to estimate the global wrist pose and position. The authors also introduce DexGloveHOI, a synchronized dataset containing egocentric video, IMU measurements, and motion-capture-based 3D hand-pose annotations across diverse manipulation tasks. The dataset contains 3.5 hours of recordings from four participants. Experiments using both UMETrack and MANO hand representations show improved joint, fingertip, and mesh accuracy over vision-only, IMU-only, and EKF-based fusion baselines, together with analyses of sensor contribution, noise robustness, and temporal misalignment.
Strengths and weaknesses
Strengths
- The paper is generally clear and well organized. The motivation, sensing setup, architecture, and experimental results are easy to follow, and the figures provide useful intuition about the proposed system.
- The paper introduces a useful multimodal dataset. DexGloveHOI contains synchronized egocentric video, 12 on-glove 6-DoF IMU streams, and motion-capture-based 3D hand-pose annotations across multiple manipulation tasks.
- The paper includes several informative analyses. The per-finger sensor study shows that an IMU generally benefits the corresponding finger most, while the noise and temporal-shift experiments demonstrate sensitivity to IMU quality and synchronization.
Strengths
- This paper features a clear structure and coherent writing style. It systematically presents the research motivation, sensing configuration, model architecture and experimental results in a well-organized sequence. All figures also clearly illustrate the core characteristics of the proposed system, helping readers easily understand the design and effects of the method.
- This study contributes a practical multimodal dataset named DexGloveHOI. The dataset integrates synchronized first-person video data, twelve 6-DoF IMU signals installed on the glove, and high-precision 3D hand pose labels generated by motion capture, covering diverse manual manipulation tasks.
- The paper conducts extensive and insightful analytical experiments. The per-finger sensor analysis confirms that each on-glove IMU mainly optimizes the pose tracking performance of its corresponding finger. Moreover, noise and temporal offset tests clearly reveal how the model performance is affected by IMU data quality and cross-modal synchronization errors. Weaknesses
- The evaluation regarding the method’s occlusion robustness is not rigorous enough. Although the paper claims that the proposed AVI-HT method performs well under occlusion conditions, it does not quantitatively verify this advantage. Specifically, the paper neither calculates hand joint visibility nor analyzes how prediction accuracy changes with different degrees of occlusion, leading to insufficient evidence for its core claim.
- The ablation experiments for model architecture are incomplete. The paper fails to independently quantify the respective roles of key modules, including IMU input, cross-attention module, kinematic mask and the secondary modality-balanced attention layer. Conducting additional comparisons with common fusion baselines such as simple feature splicing, late fusion, standard cross-attention and single-stage fusion can better demonstrate the necessity and superiority of the designed modules.
- The dataset has obvious limitations in participant diversity. While the dataset contains more than 100,000 valid frames, all data are collected from only four participants within approximately 3.5 hours of recording time. Such a narrow sample size greatly limits the dataset’s generalization ability and cannot fully support reliable cross-scene and cross-user applicability.
- The method’s generalization performance lacks comprehensive validation. All comparative experiments are completed under fixed and consistent conditions, including unified glove specifications, sensor layout, camera parameters and data collection workflows. The paper does not explore the model’s adaptability to variable settings, such as different glove tightness, sensor placement offsets, diverse IMU hardware, new users and different real-world environments.
- Multiple critical technical details are not clearly explained. First, it remains unclear how the 12 physical IMU sensors generate the 14×23×3 input feature representation described in the paper. In addition, the specific mathematical formula and hyperparameter settings of the kinematic attention mask are not fully specified, which hinders the reproducibility of the proposed method.
Questions
-
Please give a clearer evaluation of the paper’s key occlusion claim. The authors should quantify joint visibility and report prediction errors separately for visible vs. occluded joints, or across low/medium/high occlusion subgroups. This test can reuse existing hand geometry ground truth and camera parameters with no retraining needed, and it will directly validate if AVI-HT’s advantage strengthens under limited visual information. I will increase my score if performance gains are clearly concentrated on occluded joints and scale with occlusion severity.
-
Ablation studies are needed to disentangle the unique contributions of the fusion architecture. Run lightweight ablations comparing the full model against three alternatives: simple feature concatenation, cross-attention without kinematic masking, and a single-stage model lacking modality rebalancing. This will prove whether performance gains originate from the proposed hierarchical topology-aware design, rather than just added IMU features or extra parameters. My score will rise if both the kinematic prior and second-stage balancing yield consistent improvements; I will lower it if a much simpler fusion approach delivers comparable results.
Limitations
yes
Formatting concerns
There is on violation of formatting.
3 comments
We sincerely thank the reviewer for the encouraging assessment and the clear, actionable suggestions. We have run exactly the experiments the reviewer specified as decisive for the score, and the results below confirm both conditions.
Q1. Quantify the occlusion claim: errors for visible vs. occluded joints / occlusion subgroups.
To quantify the occlusion claim as suggested, we use the camera parameters and 3D ground truth to label each keypoint as occluded or visible per frame, and then bin the frames by the number of occluded keypoints, reporting F.MKPE and F.MKPE.T (the metrics most sensitive to the finger-mounted IMUs). As the table shows, the AVI-HT advantage grows monotonically with occlusion severity, from a 3.5–3.9 mm gap in the least-occluded bin to 6.2–7.5 mm in the most-occluded bin. The results confirm that the gains are concentrated on occluded joints and scale directly with occlusion severity.
| Occluded keypoints | F.MKPE UMETrack | F.MKPE AVI-HT | F.MKPE Gap | F.MKPE.T UMETrack | F.MKPE.T AVI-HT | F.MKPE.T Gap |
|---|---|---|---|---|---|---|
| [0, 5) | 16.525 | 13.034 | 3.491 | 16.532 | 12.605 | 3.927 |
| [5, 10) | 16.704 | 13.226 | 3.478 | 17.383 | 12.745 | 4.638 |
| [10, 15) | 17.835 | 13.373 | 4.462 | 18.744 | 12.936 | 5.808 |
| [15, 20) | 21.741 | 15.539 | 6.202 | 21.067 | 13.585 | 7.482 |
Q2. Ablations: concat, cross-attention without kinematic mask, single-stage without modality rebalancing.
In terms of the requested ablations, we report all variants below.
- Early concat: no attention; vision and IMU backbone features are concatenated and linearly projected.
- Late fusion: a separate IMU pose decoder; only the predicted joint angles from the vision and IMU branches are fused at the output.
- Pooled IMU token: average-pool all IMU tokens instead of taking the last token after the transformer.
- Fusion-1 only: remove the second-level self-attention.
- w/o k-prior: remove the kinematic-prior mask from the first-level attention.
Both the kinematic prior (w/o k-prior) and the second-stage rebalancing (fusion-1 only) yield consistent improvements, while the much simpler fusion approaches (early concat / late fusion) are clearly worse. This indicates that the gains stem from the proposed hierarchical, topology-aware design rather than from the added IMU features or extra parameters alone.
| Model | MKPE | F.MKPE | MKPE.T | F.MKPE.T | P.A | P.A.T |
|---|---|---|---|---|---|---|
| UMETrack | 12.342 | 17.478 | 9.359 | 17.798 | 76.059 | 81.433 |
| AVI-HT (early concat) | 11.928 | 16.935 | 8.649 | 16.545 | 76.208 | 82.629 |
| AVI-HT (late fusion) | 12.139 | 16.492 | 7.054 | 13.233 | 75.818 | 85.825 |
| AVI-HT (pooled IMU token) | 11.956 | 14.571 | 7.940 | 14.427 | 76.213 | 84.027 |
| AVI-HT (fusion-1 only) | 11.113 | 14.088 | 7.456 | 13.740 | 77.818 | 84.994 |
| AVI-HT (w/o k-prior) | 10.901 | 13.898 | 7.406 | 13.611 | 78.238 | 85.090 |
| AVI-HT (full) | 10.359 | 13.253 | 7.021 | 12.785 | 79.315 | 85.859 |
We hope these results address the reviewer's concerns, and we would be glad to run any further analyses or clarify any remaining questions during the discussion period.
Dear Reviewer CyHe,
Thanks again for your feedback. We wanted to gently follow up on our rebuttal, where we addressed your comments. We'd be glad to hear any further thoughts or answer any remaining questions.
Dear Reviewer CyHe,
Thank you for your review again. As the discussion deadline approaches, we want to kindly follow up on our rebuttal, which we hope has addressed your concerns. We'd be glad to clarify anything further, and hope you'll consider our responses when finalizing your assessment.
- Rating
- 3/6
- Confidence
- 4/5
- Quality
- 2/4
- Clarity
- 2/4
- Significance
- 2/4
- Originality
- 2/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper presents a vision-IMU fusion framework for 3D hand tracking under egocentric hand-object interaction. The system combines egocentric images with 12 on-glove 6-DoF IMUs through hierarchical cross-sensor attention and a kinematic prior mask. The authors also collect DexGloveHOI, containing 100K+ synchronized samples from four participants with marker-based motion-capture annotations. AVI-HT is evaluated with both UMETrack and MANO hand representations and reports improvements over vision-only, IMU-only, and EKF-based baselines.
Strengths and weaknesses
Strengths:
-
The problem is practically relevant. Vision and IMUs provide complementary information for hand tracking, especially when fingers are occluded during object manipulation.
-
The synchronized dataset is valuable. DexGloveHOI provides egocentric images, per-finger IMU signals, and motion-capture annotations across multiple dexterous tasks.
-
The reported improvements are consistent. AVI-HT improves both UMETrack- and MANO-based results, with particularly strong gains for fingertips and visually occluded joints.
-
The analysis is useful. The paper includes per-finger sensor analysis, activity-level results, qualitative comparisons, and sensitivity studies for IMU noise and temporal misalignment.
Weaknesses:
-
The evaluation protocol is insufficiently specified. The dataset contains only four participants, but the paper does not clearly describe the train/validation/test split or whether evaluation is subject-disjoint and session-disjoint. Adjacent video frames are highly correlated, so frame-level random splitting could significantly overestimate generalization.
-
The baseline comparison may not isolate the contribution of IMU fusion. It is unclear whether UMETrack and HaMeR are fine-tuned on DexGloveHOI using the same training data and schedule as AVI-HT. The paper should include a vision-only model with the identical backbone and training procedure, as well as simple concatenation, late fusion, and learned-gating baselines. Ablations removing the kinematic mask and the second-level attention are also needed.
-
The adaptive occlusion-aware behavior is not quantitatively demonstrated. The paper mainly uses attention visualization to argue that the model relies more heavily on IMUs during occlusion. Attention scores alone do not establish this behavior. Evaluation across annotated levels of finger visibility, together with correlation between visibility, attention weight, and tracking improvement, would provide stronger evidence.
-
Generalization and reproducibility are limited. All results are reported on a newly collected, currently unavailable dataset using one glove, one sensor layout, and a controlled seated capture setup. There is no external-dataset, cross-device, or cross-glove evaluation. Several technical details are also inconsistent, including 12 IMUs versus a 14×23×3 input representation and one versus two camera views.
-
The related-work coverage should be expanded to include work like HOOV[1], EgoPoser[2], and RPM[3]. HOOV directly studies hand tracking after the hand leaves the headset’s field of view using wrist-worn inertial sensing. EgoPoser models full-body pose from intermittent inside-out hand tracking, while RPM handles missing sparse tracking signals through rolling motion prediction. These methods target different output spaces, but they are closely relevant to the paper’s robustness claims under unavailable visual hand observations. AVI-HT should clearly distinguish its setting, i.e., finger-level occlusion while the wrist remains visually anchored, from complete hand out-of-view tracking or prolonged tracking loss.
[1] HOOV: Hand Out-Of-View Tracking for Proprioceptive Interaction using Inertial Sensing, CHI 2023
[2] EgoPoser: Robust Real-Time Egocentric Pose Estimation from Sparse and Intermittent Observations Everywhere, ECCV 2024
[3] From Sparse Signal to Smooth Motion: Real-Time Motion Generation with Rolling Prediction Models, CVPR 2025
Questions
-
What are the exact dataset splits, and are subjects, sessions, tasks, and temporally adjacent frames separated between training and testing?
-
Are UMETrack and HaMeR fine-tuned on DexGloveHOI under the same training protocol as AVI-HT?
-
Why do 12 IMUs produce a 14×23×3 input and 23 IMU feature tokens? Please clarify the sensor representation and camera configuration.
-
What is the inference latency, including image processing, IMU filtering, synchronization, fusion, and hand-pose regression?
Limitations
-
The dataset contains only four participants and may not represent diverse hand shapes, motion styles, handedness, or sensor-fitting conditions.
-
The approach depends on accurate IMU placement, calibration, and synchronization. Sensor displacement or failure may cause substantial degradation.
-
The glove changes the visual appearance and possibly the natural motion of the hand, limiting transfer to bare-hand or alternative-glove settings.
-
The method tracks the hand but does not explicitly model object pose, contact, or hand-object penetration, despite focusing on HOI scenarios.
Formatting concerns
The checklist incorrectly states that the work does not involve human subjects, despite collecting data from four participants. The answers concerning new assets and broader impacts should also be revised. There are additional grammatical and duplicated-text errors throughout the paper.
3 comments
We thank the reviewer for the careful reading.
Q1. Data splits.
AVI-HT is trained on a separate ~8M-image glove dataset; DexGloveHOI is evaluation-only. The two are disjoint in subjects, sessions, and tasks, so the split is subject-/session-disjoint with no adjacent-frame leakage.
Q2. UMETrack and HaMeR Finetuning
Both UMETrack and HaMeR are fine-tuned on the same training set, vision-only, with AVI-HT's backbones, i.e., the identical-backbone baselines requested, which isolates the IMU-fusion contribution. We also implemented all requested fusion variants:
- Early concat: concatenate backbone features + linear projection (no attention).
- Late fusion: separate IMU decoder; fuse predicted joint angles at the output.
- Pooled IMU token: average-pool all IMU tokens vs. the last token.
- Fusion-1 only: drop the second-level self-attention.
- w/o k-prior: drop the kinematic-prior mask.
| Model | MKPE | F.MKPE | MKPE.T | F.MKPE.T | P.A | P.A.T |
|---|---|---|---|---|---|---|
| UMETrack | 12.342 | 17.478 | 9.359 | 17.798 | 76.059 | 81.433 |
| AVI-HT (early concat) | 11.928 | 16.935 | 8.649 | 16.545 | 76.208 | 82.629 |
| AVI-HT (late fusion) | 12.139 | 16.492 | 7.054 | 13.233 | 75.818 | 85.825 |
| AVI-HT (pooled IMU token) | 11.956 | 14.571 | 7.940 | 14.427 | 76.213 | 84.027 |
| AVI-HT (fusion-1 only) | 11.113 | 14.088 | 7.456 | 13.740 | 77.818 | 84.994 |
| AVI-HT (w/o k-prior) | 10.901 | 13.898 | 7.406 | 13.611 | 78.238 | 85.090 |
| AVI-HT (full) | 10.359 | 13.253 | 7.021 | 12.785 | 79.315 | 85.859 |
The naive fusion baselines trail the attention design; both the kinematic mask and the second-level attention give consistent gains.
Q3. Occlusion quantitatively demonstrated.
We label each keypoint occluded/visible from camera parameters and 3D GT pose, and bin frames by occluded-keypoint count. We report F.MKPE and F.MKPE.T (most sensitive to the finger-mounted IMUs). The AVI-HT − UMETrack gap grows monotonically with occlusion, i.e., the gain concentrates where vision is lost:
| Occluded keypoints | F.MKPE UMETrack | F.MKPE AVI-HT | F.MKPE Gap | F.MKPE.T UMETrack | F.MKPE.T AVI-HT | F.MKPE.T Gap |
|---|---|---|---|---|---|---|
| [0, 5) | 16.525 | 13.034 | 3.491 | 16.532 | 12.605 | 3.927 |
| [5, 10) | 16.704 | 13.226 | 3.478 | 17.383 | 12.745 | 4.638 |
| [10, 15) | 17.835 | 13.373 | 4.462 | 18.744 | 12.936 | 5.808 |
| [15, 20) | 21.741 | 15.539 | 6.202 | 21.067 | 13.585 | 7.482 |
Q4. IMU tensor; Sensor and camera configuration.
IMU tensor. 14 = temporal window. The 23 = two features from the 12 IMUs: a gravity 3-vector each (12) + a wrist-relative gyro 3-vector (gyroₖ − gyro_wrist) for each non-reference IMU (11), i.e., 23 vectors/frame (14×23×3), one token each.
Cameras. The Quest has two egocentric cameras: AVI-HT-UME uses both stereo views (feature-transform layer, per UMETrack); AVI-HT-MANO uses a single 256×192 RGB crop with ViT.
Q5. Single dataset/glove/layout.
No existing dataset provides synchronized egocentric vision, on-glove 6-DoF IMU, and marker-based GT pose for dexterous HOI, so DexGloveHOI was a prerequisite. The layout is fixed across training and DexGloveHOI, but the architecture is not tied to it: the cross-sensor attention uses a geodesic mask over the hand skeleton (not fixed sensor indices), so a different sensor count/placement needs no change. On scope: the same glove is used, but training and DexGloveHOI remain disjoint in subjects, sessions, and tasks (Q1), so we still measure generalization to unseen users/interactions, not train-on-test.
Q6. Controlled seated setup.
The seated setup is required by the ground truth: sub-millimeter marker-based MoCap needs a calibrated, occlusion-minimized volume, constraining the subject to a fixed rig. Single-environment MoCap is standard practice (e.g., Human3.6M, ARCTIC, GRAB, HOT3D), so our protocol follows convention.
Q7. Inference latency.
Per-stage timing of the AVI-HT-UME forward pass (unoptimized):
| Stage | Image processing | IMU filtering | Synchronization | Fusion | Pose regression |
|---|---|---|---|---|---|
| Time | 82.522 ms | 3.085 ms | 3.059 ms | 0.006 ms | 49.484 ms |
The IMU-specific stages add <7 ms combined; the cost is dominated by image processing and pose regression (standard CV components). These are full-precision numbers; on-device quantization yields the ~31 ms hand-tracking budget quoted above (within ~70 ms motion-to-photon).
Q8. Related work: HOOV [1], EgoPoser [2], RPM [3].
We thank the reviewer for these pointers. The connection is thematic, not direct: [1] estimates hand-root/full-body pose (we target per-finger articulation); [2] uses a single wrist IMU or inside-out signals (we fuse vision with dense on-glove IMUs); [3] handles full dropout via temporal prediction (we address partial visual degradation via adaptive fusion). We will cite all three to situate our robustness claims.
Dear Reviewer xo2Z,
Thanks again for your feedback. We wanted to gently follow up on our rebuttal, where we addressed your comments. We'd be glad to hear any further thoughts or answer any remaining questions.
Dear Reviewer xo2Z,
Thank you for your review again. As the discussion deadline approaches, we want to kindly follow up on our rebuttal, which we hope has addressed your concerns. We'd be glad to clarify anything further, and hope you'll consider our responses when finalizing your assessment.
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper presents AVI-HT, a 3D hand-pose tracking method that fuses egocentric images with glove-mounted 6-DoF IMU signals through adaptive cross-sensor attention. The authors also introduce DexGloveHOI, a 100K+ sample vision–IMU dataset with motion-capture annotations. Experiments show improved accuracy over vision-only and multimodal baselines, especially under hand–object occlusion.
Strengths and weaknesses
The paper presents a practical vision–IMU fusion approach for 3D hand tracking under severe occlusion. Its main strengths are the synchronized DexGloveHOI dataset, MoCap supervision, evaluation with both UMETrack and MANO, and consistent gains over vision-only, IMU-only, and EKF baselines. The method is clearly motivated and potentially significant for AR/VR and teleoperation.
However, the evaluation covers only four participants in a constrained seated setting, so cross-subject and real-world generalization remain unclear. The originality is moderate, and stronger ablations against simple feature concatenation, attention without the kinematic prior, and single-level fusion are needed. Runtime, latency, and validation of the MoCap-to-hand-model annotations should also be reported.
Questions
1.How does AVI-HT generalize across unseen users and environments? A subject-independent split or per-subject results would strengthen the evaluation. 2.Please provide ablations for simple feature concatenation, attention without the kinematic prior, and single-level fusion to isolate the contribution of the proposed design. 3.How accurate is the conversion from MoCap markers to UMETrack and MANO annotations? Please report fitting errors or validation on a subset. 4.What are the runtime, end-to-end latency, and hardware requirements for real-time AR/VR or teleoperation?
Limitations
The limitations are only partially addresse. The paper should further discuss generalization beyond four participants and a constrained seated MoCap setting, robustness to sensor displacement, calibration drift, missing IMUs, and synchronization errors, and runtime/latency for real-time use. The ethics checklist should also clarify participant consent and IRB or equivalent approval.
Final justification
The experimentp limitations are only partially addressed. The method requires a specialized glove with 12 IMU sensors.,which makes the system hard to scaling.
Formatting concerns
no
3 comments
We sincerely thank the reviewer for the positive assessment and the thoughtful, constructive suggestions.
Q1. Generalization to unseen users and environments; subject-independent split, per-subject results.
We want to clarify that AVI-HT is trained on a separate, large-scale (~8 million) glove dataset, while the entire DexGloveHOI is held out for evaluation only. The two datasets use disjoint subjects and manipulation tasks by design. This is in fact a stronger form of the subject-independent split requested.
The two datasets do share a capture environment. However, the IMU modality for fusion is inherently environment-invariant. The on-glove IMU features depend only on the hand's motion and orientation, and are independent of the egocentric viewpoint. The complementary IMU cues that AVI-HT relies on therefore remain equally informative regardless of the surrounding environment.
We further evaluate the per-participant results on DexGloveHOI, which shows consistent gains over the baselines with only small variance:
| Participant | MKPE | F.MKPE | MKPE.T | F.MKPE.T | P.A | P.A.T |
|---|---|---|---|---|---|---|
| Subject 1 | 10.847 | 13.841 | 7.069 | 12.792 | 78.324 | 85.762 |
| Subject 2 | 9.624 | 12.190 | 6.548 | 12.469 | 80.797 | 86.811 |
| Subject 3 | 11.266 | 14.448 | 7.722 | 13.814 | 77.486 | 84.450 |
| Subject 4 | 8.852 | 11.512 | 6.266 | 11.311 | 82.333 | 87.371 |
Q2. Ablations
We have added the following variants:
- Early concat: no attention; vision and IMU backbone features are concatenated and linearly projected.
- Late fusion: a separate IMU pose decoder; only the predicted joint angles from the vision and IMU branches are fused at the output.
- Pooled IMU token: average-pool all IMU tokens instead of taking the last token after the transformer.
- Fusion-1 only: remove the second-level self-attention.
- w/o k-prior: remove the kinematic-prior mask from the first-level attention.
As the table shows, each component contributes, and the naive fusion baselines trail the attention-based designs by a clear margin. We attribute this to the non-negligible calibration and synchronization noise in the IMU signals. When the hand is fully visible, vision alone already suffices, and indiscriminately mixing in noisy IMU features tends to hurt. The attention design is precisely what allows the model to raise the IMU weight only when the occlusion-driven benefit outweighs this noise.
| Model | MKPE | F.MKPE | MKPE.T | F.MKPE.T | P.A | P.A.T |
|---|---|---|---|---|---|---|
| UMETrack | 12.342 | 17.478 | 9.359 | 17.798 | 76.059 | 81.433 |
| AVI-HT (early concat) | 11.928 | 16.935 | 8.649 | 16.545 | 76.208 | 82.629 |
| AVI-HT (late fusion) | 12.139 | 16.492 | 7.054 | 13.233 | 75.818 | 85.825 |
| AVI-HT (pooled IMU token) | 11.956 | 14.571 | 7.940 | 14.427 | 76.213 | 84.027 |
| AVI-HT (fusion-1 only) | 11.113 | 14.088 | 7.456 | 13.740 | 77.818 | 84.994 |
| AVI-HT (w/o k-prior) | 10.901 | 13.898 | 7.406 | 13.611 | 78.238 | 85.090 |
| AVI-HT (full) | 10.359 | 13.253 | 7.021 | 12.785 | 79.315 | 85.859 |
Q3. MoCap-to-UMETrack.
We follow UMETrack to convert the MoCap markers to hand pose. The pose annotations are produced by IK-fitting a personalized, 3DMD-scanned hand model to the labeled optical markers. We measured its per-keypoint 3D error against independent human multi-view keypoint annotations. On held-out subjects, the fit achieves a mean landmark error of 0.8–1.6 mm (≤3.25 mm at the 90th percentile), which is well below the tracking errors we report.
Q4. Runtime, end-to-end latency, hardware.
AVI-HT requires a Quest headset and the sensing glove. On-device, the end-to-end budget is ~70 ms motion-to-photon, comprising ~31 ms of hand tracking (after quantization) and ~39 ms of camera-to-display. A full per-stage breakdown of the research forward pass is also provided below. Notably, the IMU related stages together add less than 7 ms, so the added modality is not the runtime bottleneck.
| Stage | Image processing | IMU filtering | Synchronization | Fusion | Pose regression |
|---|---|---|---|---|---|
| Time | 82.522 ms | 3.085 ms | 3.059 ms | 0.006 ms | 49.484 ms |
Q5: Limitations
Generalization: detailed in Q1.
Robustness: Figure 7 quantifies robustness to CV–IMU mis-synchronization (stable within ±0.4 s) and to IMU noise. Following IMU-Tracker, we avoid drift-prone integrated orientation and rely on drift-insensitive features: per-IMU gravity vectors and wrist-relative gyroscope, which mitigates both gyroscope drift and calibration drift. Each sensor is rigidly mounted over the corresponding bony phalanx and connected through strain-relieved flex on a single per-hand bus, so finger motion rarely induces signal loss.
Ethics: All training data was collected under participant consent with IRB approval. For DexGloveHOI, we are actively completing the institutional legal and data-review process required for public release.
Dear Reviewer qJkQ,
Thanks again for your feedback. We wanted to gently follow up on our rebuttal, where we addressed your comments. We'd be glad to hear any further thoughts or answer any remaining questions.
Dear Reviewer qJkQ,
Thank you for your review again. As the discussion deadline approaches, we want to kindly follow up on our rebuttal, which we hope has addressed your concerns. We'd be glad to clarify anything further, and hope you'll consider our responses when finalizing your assessment.
Comments on the paper
1 comment
General Response (to all reviewers)
We thank all reviewers for their constructive feedback. Several concerns were raised by multiple reviewers, so we consolidate the shared results here for convenience; each reviewer's individual reply is self-contained and covers these points in full along with its reviewer-specific responses.
Setup. AVI-HT is trained on a separate ~8M-image glove dataset; DexGloveHOI is evaluation-only and disjoint in subjects, sessions, and tasks. The UMETrack and HaMeR baselines are fine-tuned on the same training set (vision-only, same backbones), isolating the IMU-fusion contribution.
(1) Fusion ablations. We compare AVI-HT against simple fusion baselines and component removals. Naive fusion (early concat, late fusion) is clearly worse, and both the kinematic prior (w/o k-prior) and the second-level attention (fusion-1 only) give consistent gains. The improvement stems from the hierarchical, topology-aware design, not from added IMU features or parameters.
| Model | MKPE | F.MKPE | MKPE.T | F.MKPE.T | P.A | P.A.T |
|---|---|---|---|---|---|---|
| UMETrack | 12.342 | 17.478 | 9.359 | 17.798 | 76.059 | 81.433 |
| AVI-HT (early concat) | 11.928 | 16.935 | 8.649 | 16.545 | 76.208 | 82.629 |
| AVI-HT (late fusion) | 12.139 | 16.492 | 7.054 | 13.233 | 75.818 | 85.825 |
| AVI-HT (pooled IMU token) | 11.956 | 14.571 | 7.940 | 14.427 | 76.213 | 84.027 |
| AVI-HT (fusion-1 only) | 11.113 | 14.088 | 7.456 | 13.740 | 77.818 | 84.994 |
| AVI-HT (w/o k-prior) | 10.901 | 13.898 | 7.406 | 13.611 | 78.238 | 85.090 |
| AVI-HT (full) | 10.359 | 13.253 | 7.021 | 12.785 | 79.315 | 85.859 |
(2) Occlusion vs. severity. Labeling each keypoint occluded/visible from camera parameters and 3D GT pose and binning by occluded-keypoint count, the AVI-HT − UMETrack gap grows monotonically with occlusion, i.e., the gain concentrates where vision is lost.
| Occluded keypoints | F.MKPE UMETrack | F.MKPE AVI-HT | F.MKPE Gap | F.MKPE.T UMETrack | F.MKPE.T AVI-HT | F.MKPE.T Gap |
|---|---|---|---|---|---|---|
| [0, 5) | 16.525 | 13.034 | 3.491 | 16.532 | 12.605 | 3.927 |
| [5, 10) | 16.704 | 13.226 | 3.478 | 17.383 | 12.745 | 4.638 |
| [10, 15) | 17.835 | 13.373 | 4.462 | 18.744 | 12.936 | 5.808 |
| [15, 20) | 21.741 | 15.539 | 6.202 | 21.067 | 13.585 | 7.482 |
(3) Per-subject generalization. On the held-out DexGloveHOI subjects, AVI-HT improves consistently with small variance, indicating the gains come from CV–IMU fusion rather than subject-specific overfitting.
| Participant | MKPE | F.MKPE | MKPE.T | F.MKPE.T | P.A | P.A.T |
|---|---|---|---|---|---|---|
| Subject 1 | 10.847 | 13.841 | 7.069 | 12.792 | 78.324 | 85.762 |
| Subject 2 | 9.624 | 12.190 | 6.548 | 12.469 | 80.797 | 86.811 |
| Subject 3 | 11.266 | 14.448 | 7.722 | 13.814 | 77.486 | 84.450 |
| Subject 4 | 8.852 | 11.512 | 6.266 | 11.311 | 82.333 | 87.371 |
(4) Latency. Per-stage timing of the AVI-HT-UME forward pass (unoptimized); the IMU stages add <7 ms, and on-device quantization yields ~31 ms hand-tracking (within ~70 ms motion-to-photon).
| Stage | Image processing | IMU filtering | Synchronization | Fusion | Pose regression |
|---|---|---|---|---|---|
| Time | 82.522 ms | 3.085 ms | 3.059 ms | 0.006 ms | 49.484 ms |
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
We thank the reviewer for the detailed comments and address each point below.
Q1. Stronger justification for the hierarchical cross-sensor attention.
We present an ablation isolating each component of the design:
As the table shows, each hierarchical level and the kinematic prior contributes, and naive fusion (early concat / late fusion) is clearly worse. The reason is that IMU calibration/synchronization noise is non-negligible, so undifferentiated fusion hurts when the hand is fully visible; the attention up-weights IMU evidence only where occlusion makes its benefit exceed that noise. This adaptive behavior is what distinguishes the design from merely adding IMU features or parameters.
Q2. More thorough ablation over the number and placement of IMUs.
Figure 6 (Per-finger IMU contribution) already provides this ablation, beyond the per-joint breakdown in Figure 4. In the left fiture, for each IMU sensor group (rows) and evaluated finger (columns), we report the MKPE.T Gap when only that group is provided, which directly quantifying both placement and sensor count. The diagonal entries (sensor and finger coincide) consistently yield the largest improvement, confirming each IMU mainly benefits its own finger, while the smaller but positive off-diagonal entries reflect kinematic coupling between neighboring fingers. Each row thus shows what is gained or lost as a sensor is added or removed.
More generally, the layout is fixed across training and evaluation, but the architecture is not bound to it: the cross-sensor attention uses a geodesic mask over the hand skeleton rather than fixed sensor indices, so a different count/placement needs no architectural change.
Q3. Substantiate the Line-167 claim.
We would like to point to the two experimental observations on which it rests. First, in Figure 6 (per-finger IMU contribution), each finger's IMU provides the largest reduction in that same finger's MKPE, which shows that the model routes each sensor primarily to its anatomically corresponding finger. Second, in the qualitative study of Figure 1, the IMU sensors whose fingers are occluded from the camera receive noticeably higher attention weights than the others. Taken together, these observations indicate that the attention adaptively increases reliance on the corresponding-finger IMU precisely when that finger is occluded.
Q4. Gravity-vector extraction; does it survive fast motion where linear acceleration contaminates the accelerometer?
We would like to clarify that gravity is not read directly from the accelerometer. Instead, each IMU runs an accelerometer+gyroscope orientation filter (EKF-style, without a magnetometer), and we take the gravity vector as the vertical axis of the fused orientation. This design is robust to fast motion because the gyroscope drives the orientation estimate and is immune to linear acceleration, while the accelerometer contributes only a low-bandwidth pitch/roll correction that filters down-weights during high dynamics. Consequently, bursts of motion acceleration are ridden out by gyroscope integration and the estimate is re-anchored once the hand slows, so the extracted gravity vector remains reliable even during rapid movement.
Q5. Explain IMU placement and the data tensor.
In terms of placement, the 12 IMUs are arranged as three on the thumb, two on each of the remaining four fingers, and one on the dorsum. In terms of the data tensor, the IMU window is 14×23×3: the 14 is the number of temporal samples, and the 23 stacks two derived features from the 12 IMUs: a gravity 3-vector per IMU (12 in total) and a wrist-relative gyroscope 3-vector, gyroₖ − gyro_wrist, for each non-reference IMU (11 in total). This yields 12 + 11 = 23 three-vectors per frame, each fed to the network as one token.
Q6. Minor typos.
We thank the reviewer for catching these typos and will correct both in the revised paper.