Abstract. A fundamental challenge in science and engineering is the simulation-to-experiment gap. While we often possess prior knowledge of physical laws, these physical laws can be too difficult to solve exactly for complex systems. Such systems are commonly modeled using simulators, which impose computational approximations. Meanwhile, experimental measurements more faithfully represent the real-world, but experimental data typically consists of observations that only partially reflect the system’s full underlying state. We propose a data-driven distribution alignment framework that bridges this simulation-to-experiment gap by pre-training a generative model on fully observed (but imperfect) simulation data, then aligning it with partial (but real) observations of experimental data. While our method is domain-agnostic, we ground our approach in the physical sciences by introducing Adversarial Distribution Alignment (ADA). This method aligns a generative model of atomic positions—initially trained on a simulated Boltzmann distribution—with the distribution of experimental observations. We prove that our method recovers the target observable distribution, even with multiple, potentially correlated observables. We also empirically validate our framework on synthetic, molecular, and experimental protein data, demonstrating that it can align generative models with diverse observables.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:46 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
I reviewed the authors' response and the discussion. The reviewer initially at 3 moved to 4. Another recommended acceptance after my follow-up, and the third stayed at 5.
The paper proposes Adversarial Distribution Alignment, which adapts a simulator-trained generator by matching distributions of partial observables. The response added an expectation-alignment control for the protein experiment. That control has little effect on held-out distances, whereas ADA improves them. A second experiment shows that ADA can infer an unknown image-noise parameter under a specified prior.
The response clarifies the experimental setting. The cryo-EM images are simulated from experimentally derived structures. This is a controlled benchmark, not validation on acquired cryo-EM data or recovery of an unbiased Boltzmann ensemble. The final paper must correct claims that describe these data as real experimental observations.
The method still requires a useful forward model. The unknown-noise test assumes a parametric, homoscedastic model and an informed prior. The protein targets are small, and the theory covers an ideal population objective rather than finite-sample training. With the experimental claims corrected, I recommend acceptance.
Final justification
My final justification is included in the metareview above.
- Final justification
- My final justification is included in the metareview above.
Read meta-review
Meta-review
I reviewed the authors' response and the discussion. The reviewer initially at 3 moved to 4. Another recommended acceptance after my follow-up, and the third stayed at 5.
The paper proposes Adversarial Distribution Alignment, which adapts a simulator-trained generator by matching distributions of partial observables. The response added an expectation-alignment control for the protein experiment. That control has little effect on held-out distances, whereas ADA improves them. A second experiment shows that ADA can infer an unknown image-noise parameter under a specified prior.
The response clarifies the experimental setting. The cryo-EM images are simulated from experimentally derived structures. This is a controlled benchmark, not validation on acquired cryo-EM data or recovery of an unbiased Boltzmann ensemble. The final paper must correct claims that describe these data as real experimental observations.
The method still requires a useful forward model. The unknown-noise test assumes a parametric, homoscedastic model and an informed prior. The protein targets are small, and the theory covers an ideal population objective rather than finite-sample training. With the experimental claims corrected, I recommend acceptance.
- Rating
- 5/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The authors present Adversarial Distribution Alignment (ADA), a method that pre-trains a generative model on simulated data and then aligns it with the distribution of observables. The motivation arises from scientists often having access to simulated data (e.g. molecular dynamics/density functional theory) yet having limited or partial access to experimental observables. The paper presents an algorithm to minimize the Wasserstein distance between the distribution corresponding to the experimental observables and that corresponding to the initial simulated data, thus also training the generative model. They present a synthetic experiment showing that ADA recovers the full target distribution of correlated Gaussians, whereas expectation alignment (EA) fails. They also present two experiments using ADA to align data generated with a lower level of DFT theory to a higher level of theory and coarse-grained proteins to PDB level of theory.
Strengths and weaknesses
Overall, this is a strong paper that tackles an important issue. As many computational chemists and scientists know, we are often faced with the issue of having a substantial amount of simulated data yet access to limited experimental measurements. I really enjoyed this paper as it is a principled application of ML to this problem.
Strengths
- The submission is technically sound. The authors do a good job of explaining their method/algorithm and provide theoretical guarantees. I appreciated how they contrasted their method with EA, as this is the method I’m the most familiar with.
- The experiments of 4.2/4.3 are also well-done. It seems quite promising that one can use ADA to align a lower level of DFT theory with a higher level given the high computational cost of DFT simulations. I believe this is of high interest to the community.
- The paper is very well-written. I found it easy to follow even as someone who is not very familiar with EA/related techniques.
Weaknesses
- I was a bit confused about what it means for something to be a partial observable. I think this could be further clarified. E.g. does it mean that it does not fully specify the state of the system/leads to an ill-posed inverse problem? An example of this could be obtaining the full crystal structure from an XRD pattern (which is of course possible using indexing algorithms but is not a one-to-one mapping).
- Algorithm 1 requires the experimental observable to be differentiable. I agree that many simple observables can be calculated in a differentiable way. I think there could be more discussion about observables that may not be differentiable/if you expect there to be any instabilities in the training process with using entropy regularized reinforcement learning.
- The paper uses simulated data (at a higher level of theory) as the “experimental data.” I think it could be better clarified that this is still simulated data and also has assumptions built into it. I think it would be really interesting to use real experimental data as these measurements are often much noisier than simulated data.
Questions
- See weaknesses, but I think it could be better clarified about what it means for something to be a partial observable. I would also clarify that you are still using simulated data to align in the experiments (which makes sense but I think people could get confused by this if they are not familiar with DFT etc.)
- I don't think this is crucial for rebuttals, but I would really want to see how this does with "true" experimental data. I agree with the authors that our supply of experimental data is quite limited, although hopefully this will change more in the future. You all may be interested in this experimental X-Ray diffraction database here (https://advanced.onlinelibrary.wiley.com/doi/10.1002/aidi.202500044).
- Figure 3 is a bit hard to read/hard to see what is going on. I wonder if it would be better to visualize the output Gaussians in 3D like you have in the appendix in Figure 5.
Limitations
Yes
Final justification
I maintain my score of 5, I believe this is a good technical work and that the authors adequately addressed my concerns.
Formatting concerns
No concerns
2 comments
Thank you to the authors for responding to my suggestions. I appreciate adding the experiment with varying levels of noise. It strengthens the case for using the ADA as experimental setups are subject to noise levels, and it is a nice addition to the paper. The clarification of partial observable also makes sense to me. I recommend that this work is accepted, as it is a useful conceptual framework for aligning experimental and simulated datasets across domains.
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 4/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The authors propose a framework where pretraining on simulated data and then aligning it with an experimental dataset. This is interesting in particular for situations where experimental data is sparse but can be artificially generated.
Strengths and weaknesses
The authors write a well-written paper addressing an important simulation-to-experiment training regime. Theoretically, the paper is well-grounded, and the paper makes a good conceptual contribution here, where observables are correlated. The paper makes a sensible attempt to address the “to-experiment” portion of their pipeline but lacks in the rationalization of choices made. The authors use long molecular dynamics as a stand in for simulated data and simulate cryo-EM images generated from PDB structures of two peptide proteins as an experimental observable (also a simulation, and unrealistic given that Cryo-EM has only been used for proteins >= 30kda). Since the model is evaluated on data more related to the base model, and not the cryo-EM observable, strong results here are expected and don’t suggest much. This makes me wonder whether the alignment is forced, real, or generalizable. In general, I would expect the utility of this method for training models to generalize to outside training data distributions. Lastly, the authors should refrain from saying “proved”.
Questions
I only have two questions, but believe they are fundamentally important to realize the capabilities of the method.
- The authors should illustrate ADA on at least one (perhaps two) real, experimental observables, whose noise cannot be controlled by mathematical metrics.
- The paper seems to neglect benchmarking against other methods, such as Smith et. al [1]. [1] https://arxiv.org/abs/2510.10020
Limitations
Without addressing the experiment aspect of the paper, the method is purely theoretical in nature.
Formatting concerns
good
1 comment
Rebuttal
We thank the reviewer for their constructive comments on the paper. We have 1) clarified the motivation for our experiments as settings that enable precise evaluation metrics on held-out observables, specifically looking at multiple observables in Sec 4.2 and high-dimensional observables in Sec 4.3, 2) added an experiment where the model must learn the parameters of the observable model with unknown noise and 3) clarified that we do benchmark against Smith et al. [1] in Sec 4.1 and 4.2 and added them as a baseline in Sec 4.3 as well. We respond in detail to individual points below.
Lacks in the rationalization of choices made
We thank the reviewer for raising this point and would like to clarify the motivation behind our experimental design. Our experiments are designed to evaluate three aspects of ADA: 1) why full distribution alignment provides advantages over expectation alignment (EA), which matches only selected moments of a distribution, 2) how ADA handles multiple observables, and 3) how ADA scales to high-dimensional observables.
To this end, we first use a synthetic experiment to build intuition for why moment-based alignment methods can fail to recover full distributions, particularly in high-dimensional settings (sec. 4.1). We then evaluate how ADA handles multiple molecular observables, comparing against EA (sec. 4.2). Finally, we consider cryo-EM image observables to test ADA on a high-dimensional measurement that is a noisy function of the underlying molecular state (sec. 4.3). We have additionally included an explicit comparison to EA in this setting. As expected, EA struggles in this regime due to the high-dimensional observable (see our response below to Smith et al. baseline for details).
While these experiments do not fully capture the complexity of a real experimental pipeline, their purpose is to systematically understand the behavior of ADA under controlled conditions. These settings allow us to quantitatively evaluate distribution alignment through held-out observables, providing insight into when and why ADA succeeds. We will clarify this motivation in the final version of the text.
The authors should illustrate ADA on… experimental observables whose noise cannot be controlled
We perform an additional experiment where the imaging noise model is not known exactly. We demonstrate that ADA is capable of recovering both the noise parameter and improving the base distribution with the simulated cryo-EM images.
Instead of providing the full observable model, we give ADA a prior over the noise distribution and make ADA jointly infer the noise parameters while aligning the observable distributions. We form each cryo-EM image at a signal-to-noise ratio (SNR) drawn from . The model is provided only with an informed prior over the SNR, , since the typical SNR of a cryo-EM measurement is often known but can vary slightly from measurement to measurement.
In addition to the standard ADA objective, the model now variationally infers the SNR distribution, jointly learning a variational posterior over the SNR (regularized toward the prior via a KL term) while aligning to the observable. In effect, the model must recover part of the observable (forward) model itself, rather than being handed the exact imaging operator. This can be formalized in the ADA framework by considering the underlying states to be tuples of the protein conformation and noise level of the instrument.
Our results show that ADA can jointly recover the SNR distribution and substantially improve alignment of the base model to the experimental structures. On held-out observables, the Wasserstein distance to the experimental radius-of-gyration distribution drops from 1.07 to 0.25, and from 1.26 to 0.26 for the mean interatomic distance distribution, while the inferred SNR concentrates near its true value (learned ).
We note that robustness to lower SNR and more complex parametric families of noise remain to be tested and remain interesting directions for future work; this experiment demonstrates that ADA can remain effective even when the observable model is only partially specified, assuming a reasonable prior.
The paper seems to neglect benchmarking against other methods, such as Smith et. al [1]. [1] https://arxiv.org/abs/2510.10020
We would like to clarify that we do benchmark against Smith et al. [1] for small molecules. We additionally add the baseline for the cryo-EM experiments.
The two alignment methods proposed in [1] both fall within the category of what we call expectation alignment (EA) methods in this work, since they perform alignment based on specific moments. In particular, our EA baselines in sections 4.1, 4.2, and 4.3 are the CGM-Relax loss formulation from Smith et al. (we chose CGM-Relax as both of their methods provide comparable results).
In our synthetic small molecules case on MD-17, we demonstrate overall better alignment to the DFT reference on trained and held-out observables. In addition, we demonstrate that using full distributional alignment, instead of just moment-based alignment, allows the model's underlying prior to better fit the free-energy profiles of correlated observables [Table 5]. We have also added an EA baseline to the experiment in section 4.3, underscoring how moment-based methods struggle with very high-dimensional observables. Note that there are already 2nd-order moments, so using all 3rd-order moments is infeasible on modern hardware. We will clarify the EA baseline in the final version of the manuscript.
| to Experiment () | ||
|---|---|---|
| MeanDist | ||
| Trp-Cage Base | 1.26 | 1.07 |
| EA (SNR 1.0, 1st order moments) | 1.28 | 1.02 |
| EA (SNR 1.0, 1st$+$2nd order moments) | 1.25 | 1.08 |
| ADA (SNR 1.0) | 0.17 | 0.21 |
| ADA (SNR 0.1) | 0.28 | 0.36 |
| BBL Base | 1.36 | 1.08 |
| EA (SNR 1.0, 1st order moments) | 1.23 | 0.98 |
| EA (SNR 1.0, 1st$+$2nd order moments) | 1.26 | 1.01 |
| ADA (SNR 1.0) | 0.21 | 0.18 |
| ADA (SNR 0.1) | 0.27 | 0.33 |
Cryo-EM has only been used for proteins >= 30kda
While we agree the size of the proteins does not reflect a fully realistic cryo-EM imaging scenario, we focus this paper on understanding the full distribution matching problem setting and evaluating ADA. The fast folding proteins [2] are a commonly used dataset to evaluate models on proteins, and we use it to specifically examine handling of high-dimensional observables. We think further evaluation with real experimental data is an interesting direction for future work.
Lastly, the authors should refrain from saying “proved”.
We will update our wording in the final version of the manuscript.
[1] Henry D. Smith, Nathaniel L. Diamant, & Brian L. Trippe. (2026). Calibrating Generative Models to Distributional Constraints.
[2] Lindorff-Larsen, K., Piana, S., Dror, R., & Shaw, D. (2011). How Fast-Folding Proteins Fold. Science, 334(6055), 517–520.
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 2/4
- Significance
- 3/4
- Originality
- 4/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The goal of the paper is to finetune a generative model of some distribution, on a new distribution where only noisy, projected, or otherwise partially observed samples are available. First a generative model is trained on a initial and fully observable distribution, like structures from molecular dynamics. Then the generative model is trained Wasserstein-GAN style, where measurement outcomes (e.g. a 2D projection "image" of a 3D structure) are computed from the generative model and a critic/discriminator tries to discern them from real measurements. The generator is then updated (using adjoint matching) to match the experimental observable distributions while remaining close to the simulation-trained base model via a KL regularizer.
Strengths and weaknesses
Strengths
-Clean problem formulation, and aligning generative models to experimental data is an important problem
-Good conceptual explanation why matching full observable distributions is stronger than matching only expectations (the typical mean matching) -Technically sound method
Weaknesses
I found the stated goal of the paper and the evaluation confusing. This could in part be due to different lingo between molecular simulation and RL.
The paper has a lot of potential and would greatly benefit from clarifying these:
-From my understanding, the simulated cryo-EM images from NMR structures benchmark does not make sense beyond as a controllable toy example. Neither NMR nor actual cryo-EM structures follow a Boltzmann distribution or any other physically interesting distribution. This is especially true for the small empirical NMR (29 Trp-cage structures and 21 BBL structures) distribution used in the paper as "target". Unless I am wrong (which is possible), this should either be clearly acknowledged throughout the paper, or a more reasonable task should be used. As far as I know, there is no real way of obtaining unbiased 3D molecular structures.
-The distinction between ensemble-averaged observables vs single-structure observables should be clarified for the audience of molecular-simulation practitioners. In molecular simulation observables often refer to expectation values of a distribution over structures.
-As I understand it, the paper targets (a distribution over) measurements of single structures. You need some way to produce the observable (the same kind as the experimental measurement performs) from a generated structure. This is essentially simulating the measurement process computationally, which might not always be possible, or cause the critic to latch onto spurious correlations if not done perfectly.
Questions
See weaknesses
Limitations
It should be emphasized that you need some way to produce the observable (the same kind as the experimental measurement performs) from a generated structure. This is essentially simulating the measurement process computationally, which might not always be possible, or cause the critic to latch onto spurious correlations if not done perfectly.
Final justification
The authors addressed most of my concerns in the rebuttal and i therefore raise my score and recommend acceptance
Formatting concerns
None
3 comments
Rebuttal
We thank the reviewer for their comprehensive response. We have 1) clarified the motivation for the cryo-EM benchmark as a setting that evaluates handling high-dimensional observables while still enabling precise evaluation metrics on held-out observables and 2) added an experiment where the model must learn parameters of the observable model. We respond in detail to individual points below.
Cryo-em image benchmark…does not make sense beyond as a controllable toy example.
We thank the reviewer for the opportunity to clarify. We agree that in a real-world setting, aligning to cryo-EM measurements would not recover the true exact Boltzmann distribution, but rather a potentially biased experimental ensemble. We agree that this distinction should be clarified, as all experimental procedures introduce biases.
However, the presence of such biases does not mean that recovering experimentally observed ensembles is without scientific value. Cryo-EM distributions provide information about conformational heterogeneity, protein dynamics, and functional mechanisms [1,2]. Thus, recovering an experimentally observed ensemble remains an important problem, even when it does not correspond exactly to the underlying Boltzmann landscape.
We present the simulated cryo-EM alignment experiment as an incremental step toward this broader goal. The goal of this experiment is not to recover an unbiased physical ensemble, but to demonstrate ADA’s ability to align distributions from high-dimensional, noisy observables in a setting where validation with respect to a reference set of structures is possible.
Given a distribution of cryo-EM images, we evaluate whether ADA can align distributions when observations are noisy and high-dimensional functions of the underlying molecular state. Using structures from the PDB provides a setting where the target ensemble is known, allowing quantitative evaluation through held-out observables. Extending this approach to more realistic settings where the underlying distribution is unknown, including by running rigorous experimental evaluations in a wet lab, is an important direction for future work. We will be sure to clarify the motivation for this experiment in the final version of the manuscript.
You need some way to produce the observable
As noted by the reviewer, ADA does require a forward model for the observable, i.e., a way to simulate the measurement from a generated structure. In many settings, such forward models are well established [3,4], although we agree that care is required when the observable model is imperfect or only partially known.
To address this concern, we performed an additional experiment where the imaging noise model is not provided exactly. Instead, ADA is given only a prior over the noise distribution and jointly infers the noise parameters while aligning the observable distributions.
We form each cryo-EM image at a signal-to-noise ratio (SNR) drawn from . The model is provided only with an informed prior over the SNR, , since the typical SNR of a cryo-EM measurement is often known but can vary from measurement to measurement.
In addition to the standard ADA objective, the model now variationally infers the SNR distribution, jointly learning a variational posterior over the SNR (regularized toward the prior via a KL term) while aligning to the observable. In effect, the model must recover part of the observable (forward) model itself, rather than being handed the exact imaging operator. This can be formalized in the ADA framework by considering the underlying states to be tuples of the protein conformation and noise level of the instrument.
Our results show that ADA can jointly recover the SNR distribution and substantially improve alignment of the base model to the experimental structures. On held-out observables, the Wasserstein distance to the experimental radius-of-gyration distribution drops from 1.07 to 0.25, and from 1.26 to 0.26 for mean-interatomic-distance distribution, while the inferred SNR concentrates near its true value (learned ).
We note that robustness to lower SNR and more complex parametric families of noise remain to be tested and remain interesting directions for future work; this experiment demonstrates that ADA can remain effective even when the observable model is only partially specified, assuming a reasonable prior.
Ensemble-averaged observables vs single-structure observables
We speak specifically of “single-structure observables”, which are quantities determined by a single structure. An experiment provides a distribution of possible measurements. We appreciate the feedback and will make this terminology distinction in the final version of the paper to avoid confusion with "ensemble-averaged observables".
[1] Frank, J., & Ourmazd, A. (2016). Continuous changes in structure mapped by manifold embedding of single-particle data in cryo-EM. Methods, 100, 61–67.
[2] Fernandez-Leiro, R., & Scheres, S. (2016). Unravelling biological macromolecules with cryo-electron microscopy. Nature, 537(7620), 339–346.
[3] P. Debye. Zerstreuung von Röntgenstrahlen. Annalen der Physik. 1915. Vol. 351(6):809-823. DOI: 10.1002/andp.19153510606
[4] Zhong, E., Bepler, T., Berger, B., & Davis, J. (2021). CryoDRGN: reconstruction of heterogeneous cryo-EM structures using neural networks. Nature Methods, 18(2), 176–185.
I thank the authors for their response. I agree with the new framing, which is substantially different from the claims, at least on the surface level, in the previously submitted version of the paper. I think the method is good, but the claims in the manuscript were misleading.
Specifically, these clarifications in the rebuttal should be made throughout the manuscript:
-
the method does not target the Boltzmann distribution, but a distribution of experimental observations (which in the experiments is not all a Boltzmann distribution) the method requires access to a forward model
-
the experiments on learning the SNR are a welcome addition, but again require assumptions about the analytical form of the forward model, which is difficult in practice (e.g. most experimental errors are not i.i.d. or homoscedastic)
We thank the reviewer for the thoughtful follow-up.
Our goal is to introduce and study ADA, a general framework for distributional alignment from partial observations. The method applies to arbitrary target distributions—including, but not limited to, Boltzmann distributions with a physical potential—and only assumes full support over the domain (Theorem 3.1). Likewise, ADA assumes access to a forward model of the observable, a standard assumption in simulation-based inference and inverse problems [1,2,3,4,5,6,7]. Such forward models are available for many experimental modalities, making this assumption reasonable in a broad range of scientific applications. As shown in our additional rebuttal experiment, ADA can also jointly learn unknown components of the forward model. We therefore view these points about the forward model as assumptions of the application setting rather than limitations of our distribution alignment framework itself, and will make this distinction clearer throughout the revised manuscript.
The method does not target the Boltzmann distribution
We agree that our method does not target specifically Boltzmann distributions, governed by physical potentials. Our method aligns to any distribution of interest, for which one can attain a set of experimental measurements for, and provided the conditions of Theorem 3.1 hold.
Assumptions about the analytical form of the forward model
While we do assume some knowledge of the observable forward model, we note that this is a standard assumption in many works that study inverse problems [1,2,3,4,5,6,7]. Many measurements have well-known forward models [8,9,3], and the experiment in our rebuttal, while preliminary, provides evidence that unknown components of such forward models can be learned with ADA.
We agree that measurements are often neither i.i.d. nor homoscedastic. While we model the imaging noise as homoscedastic in our follow-up experiment, the formulation naturally extends to sample-dependent noise models. More broadly, there will always be modeling choices that depend on the application (e.g., the forward model, neural network architecture, data selection). These choices are complementary to ADA, whose contribution is a general framework for distributional alignment that can be combined with different forward models, including those that are only partially specified.
We thank the reviewer for the feedback. We will clarify these points based on the reviewer's helpful comments. Please let us know if there are any remaining questions or concerns.
[1] Henry D. Smith, Nathaniel L. Diamant, & Brian L. Trippe. (2026). Calibrating Generative Models to Distributional Constraints.
[2] Maddipatla, A., Sellam Bojan, N., Bojan, M., Masalitin, V., Vedula, S., Schanda, P., Marx, A., & Bronstein, A. M. (2026). Experiment-guided AlphaFold3 resolves measurement-consistent protein ensembles. Nature Biotechnology. https://doi.org/10.1038/s41587-026-03166-5
[3] Soper, A. K. (1996). Empirical potential Monte Carlo simulation of fluid structure. Chemical Physics, 202(2–3), 295–306. https://doi.org/10.1016/0301-0104(95)00357-6
[4] Tang, W. S., Zhong, E. D., Hanson, S. M., Thiede, E. H., & Cossio, P. (2023). Conformational heterogeneity and probability distributions from single-particle cryo-electron microscopy. Current Opinion in Structural Biology, 81, 102626. https://doi.org/10.1016/j.sbi.2023.102626
[5] Ayush Tewari, Tianwei Yin, George Cazenavette, Semon Rezchikov, Joshua B. Tenenbaum, Fredo Durand, William T. Freeman, & Vincent Sitzmann (2023). Diffusion with Forward Models: Solving Stochastic Inverse Problems Without Direct Supervision. In Thirty-seventh Conference on Neural Information Processing Systems.
[6] Bin Han, & Kuang Yu. (2024). Refining Potential Energy Surface through Dynamical Properties via Differentiable Molecular Simulation.
[7] Tang, W. S., Silva-Sánchez, D., Giraldo-Barreto, J., Carpenter, B., Hanson, S. M., Barnett, A. H., Thiede, E. H., & Cossio, P. (2023). Ensemble Reweighting Using Cryo-EM Particle Images. The Journal of Physical Chemistry B, 127(24), 5410–5421. https://doi.org/10.1021/acs.jpcb.3c01087
[8] P. Debye. Zerstreuung von Röntgenstrahlen. Annalen der Physik. 1915. Vol. 351(6):809-823. DOI: 10.1002/andp.19153510606
[9] Zhong, E., Bepler, T., Berger, B., & Davis, J. (2021). CryoDRGN: reconstruction of heterogeneous cryo-EM structures using neural networks. Nature Methods, 18(2), 176–185.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Rebuttal
We appreciate the detailed feedback from the reviewer. We have 1) clarified our experimental setting as using simulated data in order to enable precise evaluation metrics on held-out observables and 2) added an experiment where the model must learn parameters of the observable model and expanded the discussion on assumptions surrounding the observable model. We respond in detail to individual points below.
We agree that this is an important point and will expand the discussion around the assumption of differentiability in the final version of the manuscript. The requirement of differentiability comes from our use of adjoint matching to optimize our distribution matching objective with respect to the diffusion model. Many observables have a corresponding differentiable formulation, including cryo-EM image formation (used in this paper, adapted from [1]). However, our general distribution matching formulation and related theorems are independent of the underlying implementation, and other optimization methods could be used for non-differentiable observables. As the reviewer notes, while methods that tackle non-differentiable reward-optimization scenarios have their own challenges, including maintaining stability, there is a rich body of literature tackling those settings [2,3,4,5]. One could also train a (differentiable) neural network to estimate a non-differentiable observable and use the learned model in the ADA loop.
We have also added an experiment where the model does not know the full observable model and must learn the noise parameter at the same time that it aligns with the cryo-EM observable.
We form each cryo-EM image at a signal-to-noise ratio (SNR) drawn from N(1,0.2). The model is provided only with an informed prior over the SNR, N(0.8,0.4), since the typical SNR of a cryo-EM measurement is often known but can vary slightly from measurement to measurement.
In addition to the standard ADA objective, the model now variationally infers the SNR distribution, jointly learning a variational posterior over the SNR (regularized toward the prior via a KL term) while aligning to the observable. In effect, the model must recover part of the observable (forward) model itself, rather than being handed the exact imaging operator. This can be formalized in the ADA framework by considering the underlying states to be tuples of the protein conformation and noise level of the instrument.
Our results show that ADA can jointly recover the SNR distribution and substantially improve alignment of the base model to the experimental structures. On held-out observables, the Wasserstein distance to the experimental radius-of-gyration distribution drops from 1.07 to 0.25, and from 1.26 to 0.26 for the mean interatomic distance distribution, while the inferred SNR concentrates near its true value (learned N(0.98,0.19)).
We note that robustness to lower SNR and more complex parametric families of noise remain to be tested and remain interesting directions for future work; this experiment demonstrates that ADA can remain effective even when the observable model is only partially specified, assuming a reasonable prior.
We will be sure to clarify this in the final version of the manuscript and agree that this is an important point to get across clearly. The reason we use simulated data at multiple levels of theory is so that we can still calculate meaningful validation metrics across a wide range of observables (including held-out ones) by using the full simulated structures. That way we can report performance not just on the single observable used for alignment (where it wouldn’t be surprising to see improvement), but on other metrics as well.
By a “partial observable”, we mean a function of the full underlying state of the system that is not necessarily invertible. As noted by the reviewer, this means that knowing a single observable does not give enough information to reconstruct the exact underlying state that generated the observation. Examples from the paper include the synthetic 2D projections which provide a partial observation of the full 3D state and a cryo-EM image of an underlying 3D protein structure. We will clarify our use of partial observation in the final manuscript.
We agree that it would be interesting to further evaluate ADA in an even more realistic experimental setting. We think of the main contribution of this work as primarily studying the algorithm and understanding its performance, with experiments that provide evidence that it can handle high-dimensional and multi-observable settings. We hope to work with further experimental data, including with experimental validation across more observables, but we leave that for future work. We will definitely look at the reference database suggested by the reviewer in more detail. Thank you for the suggestion!
Thank you for the comment. We initially chose the 2D projections since they provided a less cluttered visualization than a 3D version, but agree that these can be difficult to interpret. We will refine a clearer visualization for the final version of the manuscript.
[1] Zhong, E., Bepler, T., Berger, B., & Davis, J. (2021). CryoDRGN: reconstruction of heterogeneous cryo-EM structures using neural networks. Nature Methods, 18(2), 176–185.
[2] Daniel M. Ziegler, Nisan Stiennon, Jeffrey Wu, Tom B. Brown, Alec Radford, Dario Amodei, Paul Christiano, & Geoffrey Irving. (2020). Fine-Tuning Language Models from Human Preferences.
[3] Kevin Black, Michael Janner, Yilun Du, Ilya Kostrikov, & Sergey Levine. (2024). Training Diffusion Models with Reinforcement Learning.
[4] Zhihong Shao, Peiyi Wang, Qihao Zhu, Runxin Xu, Junxiao Song, Xiao Bi, Haowei Zhang, Mingchuan Zhang, Y. K. Li, Y. Wu, & Daya Guo. (2024). DeepSeekMath: Pushing the Limits of Mathematical Reasoning in Open Language Models.
[5] John Schulman, Filip Wolski, Prafulla Dhariwal, Alec Radford, & Oleg Klimov. (2017). Proximal Policy Optimization Algorithms.