potentialpaper

SynTeX-FL: Cross-Modal Text Transfer in Federated Learning for Medical Visual Question Answering

Min Hyuk Kim, Do Hyun Ki, Seok Bong Yoo

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

Abstract. Medical visual question answering (VQA) and federated learning (FL) have gained prominence as critical methods for clinical artificial intelligence, with VQA supporting image-based diagnostic reasoning and FL allowing institutions to train models jointly without sharing sensitive patient data. However, existing approaches face substantial challenges in cross-modal vertical FL settings, where each participating institution possesses unimodal, modality-specific textual data without access to paired multimodal samples. To address this limitation, we introduce SynTeX-FL, a federated framework designed to enable cross-modal text transfer for medical VQA without sharing raw data. Moreover, SynTeX-FL applies a reconstruction-based text synthesis model that extracts clinically relevant semantics from medical images to generate cross-modal textual representations. Furthermore, the proposed method incorporates modality-specialized low-rank adaptation (LoRA) modules to enhance modality-aware representations for each imaging domain. During aggregation, the central server employs discriminator-based quality scores and source-aware weighting strategies to integrate heterogeneous client contributions. Extensive experiments on multimodal medical VQA benchmarks demonstrate that SynTeX-FL significantly outperforms current FL baselines, providing a robust and efficient solution for cross-modal reasoning in decentralized clinical environments.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
29 Apr 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:45 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

The paper studies cross-model vertical federated learning for medical VQA, where hospitals hold unimodal data (X-ray, CT, or MRI) with no paired multimodal samples across institutions. Specifically, the paper proposes a two-stage pipeline. Stage one will conduct cross-model text synthesis. Stage two will perform LoRA finetuning.

Strengths:

  1. The problem is very important given low-resource settings and modality bias in the medical domain.
  2. The proposed federated text-synthesis formulation is elegant. LoRA is an appropriate method for modality heterogeneity. uses text as a common semantic interface.
  3. The paper also did quality aware weighting.

Weaknesses:

  1. Reviewers question the core promise based on clinical grounds, since X-ray, CT, and MRI reports also have different imaging physics and describe different observable findings. The paper therefore needs to demonstrate not merely that the text sounds like an MRI report, but that each clinical statement is supported by the available source evidence.
  2. Cycle reconstruction verifies only that generated text can recover the source-modality text. The discriminator verifies only that output resembles a medical report. Neither signal can establish that synthetic MRI text reflects MRI-visible pathology.
  3. The hallucination risk is not properly analyzed.
  4. "Without paired multimodal samples" is misleading when every client still requires paired image–text data for its own modality
  5. No dedicated strong medical VQA system is included.

Issues that could materially change the recommendation

  1. The paper needs to provide evidence that synthetic target-modality text is clinically grounded rather than merely linguistically plausible. Authors can report clinical-label consistency. Something like qualitative clinical validation also could work.
  2. The paper needs to include more ablations isolating synthetic cross-modal text, and the modality-specific baselines. The paper can also provide modality-specific LoRA modules on real data.
Final justification

I have read the author's rebuttal and discussion with reviewers. Reviewer V9a1 stated that most concerns were addressed and raised the score. Reviewer VWQW similarly stated that the additional experiments addressed most concerns and raised the score. Reviewer B498 remained at borderline reject, primarily because of concerns about the scope of the contribution, privacy guarantees, and clinical validation.

Issues in my metareview have been fully addressed.

Overall, reviewers are leaning towards positive.

Area Chair 2pf2 · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

The paper studies cross-model vertical federated learning for medical VQA, where hospitals hold unimodal data (X-ray, CT, or MRI) with no paired multimodal samples across institutions. Specifically, the paper proposes a two-stage pipeline. Stage one will conduct cross-model text synthesis. Stage two will perform LoRA finetuning.

Strengths:

  1. The problem is very important given low-resource settings and modality bias in the medical domain.
  2. The proposed federated text-synthesis formulation is elegant. LoRA is an appropriate method for modality heterogeneity. uses text as a common semantic interface.
  3. The paper also did quality aware weighting.

Weaknesses:

  1. Reviewers question the core promise based on clinical grounds, since X-ray, CT, and MRI reports also have different imaging physics and describe different observable findings. The paper therefore needs to demonstrate not merely that the text sounds like an MRI report, but that each clinical statement is supported by the available source evidence.
  2. Cycle reconstruction verifies only that generated text can recover the source-modality text. The discriminator verifies only that output resembles a medical report. Neither signal can establish that synthetic MRI text reflects MRI-visible pathology.
  3. The hallucination risk is not properly analyzed.
  4. "Without paired multimodal samples" is misleading when every client still requires paired image–text data for its own modality
  5. No dedicated strong medical VQA system is included.

Issues that could materially change the recommendation

  1. The paper needs to provide evidence that synthetic target-modality text is clinically grounded rather than merely linguistically plausible. Authors can report clinical-label consistency. Something like qualitative clinical validation also could work.
  2. The paper needs to include more ablations isolating synthetic cross-modal text, and the modality-specific baselines. The paper can also provide modality-specific LoRA modules on real data.
Final justification

I have read the author's rebuttal and discussion with reviewers. Reviewer V9a1 stated that most concerns were addressed and raised the score. Reviewer VWQW similarly stated that the additional experiments addressed most concerns and raised the score. Reviewer B498 remained at borderline reject, primarily because of concerns about the scope of the contribution, privacy guarantees, and clinical validation.

Issues in my metareview have been fully addressed.

Overall, reviewers are leaning towards positive.

1 comment
Authors · CommentOpenReview ↗

Response to initial meta-review

We thank the Area Chair for identifying the two issues that could materially affect the recommendation. We summarize how our responses address them below.

1. Clinical grounding and hallucination risk

We clarify that SynTeX-FL is a training-time semantic augmentation framework that preserves source-supported evidence while reflecting modality-specific observability, rather than predicting reports for unobserved target-modality examinations.

We also provide a summary of the qualitative clinical validation presented in Figs. 3–17 of the Appendix, which include synthetic target-modality text and downstream VQA responses with annotations based on clinicians’ assessments. These examples provide qualitative evidence that SynTeX-FL preserves source-supported findings while expressing them in forms consistent with target-modality observability. For example, in Fig. 14, X-ray “bilateral fluffy infiltrates” are expressed on MRI as “bilateral areas of increased signal intensity,” which is physically plausible because pulmonary edema increases lung water content and may produce high signal on fluid-sensitive MRI sequences. The absence of cardiomegaly is also preserved, supporting the non-cardiogenic interpretation.

We further evaluate clinical-label consistency between the source reports and the corresponding generated target-modality reports for 996 source cases across five prespecified clinical-label categories. The cases were approximately evenly divided into disjoint subsets and assigned to five clinicians, who were blinded to the generation method. For each assigned case, the clinicians labeled each finding as present or absent in the source report and in each corresponding generated target-modality report. As shown in the table below, SynTeX-FL achieves an accuracy of 97.5%, a precision of 94.3%, a recall of 98.9%, an F1 score of 96.5%, and a visibility-violation rate of 3.4%, substantially outperforming NAST and TST-CycleGAN. These results show that the generated reports preserve source-supported clinical findings and respect target-modality visibility constraints, beyond merely matching modality-specific language.

Metric Clinical-label Consistency
Accuracy ↑ Precision ↑ Recall ↑ F1 score ↑ Visibility Violation Rate ↓
NAST 72.2 70.5 70.8 70.6 18.4
TST-CycleGAN 79.1 80.1 73.9 76.9 14.5
SynTeX-FL 97.5 94.3 98.9 96.5 3.4

We also clarify that the original submission already included complementary evaluations using clinician-recommended sensitivity and PPV, along with finding-level correctness (Main Fig. 5 and Lines 303–305; Appendix Fig. 2 and Tables 11 and 13). These results demonstrate that SynTeX-FL better preserves source-supported findings while reducing omissions and unsupported additions.

2. Synthetic-text contribution and modality-specific baselines

We clarify that the last row of Main Table 5 corresponds to the setting without cross-modal text, in which cross-modal synthesis and its associated modality-specialized LoRA modules are jointly removed.

We also add the requested real-only modality-specific LoRA baseline on the LLaVA-Med and VQA-RAD datasets, where each modality-specialized LoRA module is trained exclusively on real data from its corresponding modality without synthetic cross-modal text. As shown in the tables below, SynTeX-FL improves accuracy on VQA-RAD from 65.76% to 73.89% overall, from 52.04% to 61.46% on open-ended questions, and from 73.26% to 82.10% on closed-ended questions. The same trend is observed across all metrics on LLaVA-Med. These results isolate the benefit of synthetic cross-modal supervision beyond standard real-only modality-specific adaptation.

LLaVA-Med

Metric ROUGE-L METEOR CIDEr BLEU-1 BLEU-5
Real-only LoRA 0.3690 0.3398 0.5112 0.2884 0.1427
SynTeX-FL 0.4057 0.3727 0.5543 0.3309 0.1740

VQA-RAD

Setting Overall Open Closed
Real-only LoRA 65.76 52.04 73.26
SynTeX-FL 73.89 61.46 82.10

\rule{0pt}{2.0em} We also clarify the absence of same-patient paired samples across medical imaging modalities, report additional evaluations using dedicated medical VQA backbones, and provide further clarification on the architecture of the synthetic-report generator, the privacy aspects of the discriminator score, and the non-centralized training procedure of the synthesis module. We kindly ask the Area Chair to also consider our detailed responses to Reviewers V9a1, B498, and VWQW, which provide further supporting evidence and methodological details for the points summarized above.

\rule{0pt}{2.0em} We hope that these additional results and clarifications directly address the issues highlighted in the initial meta-review. We welcome any further questions or discussion.

Reviewer VWQWOpenReview ↗
Rating
4/6
Confidence
5/5
Quality
3/4
Clarity
3/4
Significance
2/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

A federated learning framework, SynTeX-FL, is proposed in this paper for medical visual question answering. To bridge cross-modal heterogeneity, clinically meaningful textual representations are synthesized from medical images and modality-to-modality semantic transfer are performed without learning from paired multimodal samples. Modality-specialized LoRA modules is applied to improve representation learning across different imaging domains, and discriminator-based quality scores and source-aware weighting are employed to integrate heterogeneous client contributions.

Strengths and weaknesses
  1. The proposed approach is under the assumption that data from one imaging modality can be used to synthesize textual information to improve models for another modality. However, this assumption is questionable because different medical imaging modalities capture different anatomical and pathological information.
  2. Generating MRI-style or CT-style text from X-ray data is likely to produce text that is statistically reasonable rather than clinically grounded. X-ray reports, CT reports, and MRI reports are not different merely in writing styles. They correspond to different imaging physics and different observable findings.
  3. There is no ground-truth validation for the synthetic target-modality text. For example, when generating MRI text from X-ray data, the training process does not use paired MRI images or real MRI reports from the same patient as supervision. Cycle reconstruction only verifies whether the generated text can reconstruct the source-modality text, and the discriminator only judges whether the text resembles a medical report. Neither mechanism ensures that the synthetic MRI text reflects MRI-visible pathology accurately.
  4. There is a risk of clinical hallucination. The generated cross-modal text may appear medically reasonable but contain findings that are not supported by the source image. The paper does not sufficiently demonstrate that synthetic CT/MRI text generated from X-ray data is medically reliable or clinically meaningful.
  5. The necessity of synthetic cross-modal transfer is not addressed sufficiently. Since there are real CT clients and real MRI clients in the federated setting, a more natural approach would be to train CT-specific adapters using real CT data and MRI-specific adapters using real MRI data. The additional benefit of having an X-ray client generate MRI-style text for MRI adapter training is not clearly described, while this step adds noise and potential hallucination risks.
  6. The proposed method is closer to modality-specific federated learning than true multimodal federated learning.
Questions
  1. Please justify why text synthesized from one modality(e.g., X-ray) can provide medically meaningful supervision for another modality(such as CT or MRI), given different imaging physics and observable findings. My evaluation score would improve if the authors provide evidence that the generated text is clinically grounded rather than only linguistically reasonable.

  2. The current reconstruction and discriminator losses cannot validate whether synthetic CT/MRI text is medically correct. A small-scale expert review or clinical-label consistency analysis would help assess hallucination risk. My score would increase if the authors show low hallucination and high clinical consistency.

  3. Comparison with modality-specific adapter baselines. The authors should compare against training CT/MRI-specific adapters using only real modality data without cross-modal synthetic text, which can validate whether synthetic transfer provides benefits beyond standard modality-specific FL.

  4. Ablation on synthetic cross-modal text. Please report results without synthetic text, with only same-modality text, or with different weights of synthetic text. It can validate whether the synthesis module truly contributes to the gains or mainly introduces noise. My evaluation would improve if the gains remain consistent and stable.

Limitations

No. The paper does not sufficiently discuss the limitations and implications of relying on synthetic cross-modal medical text. In particular, the authors should explicitly describe the risk that generated CT/MRI-style text may be clinically reasonable but not supported by the source modality, leading to potential hallucinated findings. They should also discuss the lack of target-modality ground-truth supervision for validating synthetic text, and the possible negative impact of using such text in clinical VQA systems.

Final justification

The authors' response addressed most of my concerns. More experiments were conducted to validate the proposed issues. I have raised my score. For my proposed concerns, currently they are verified via experiments. I hope more rational analysis will be explained to strengthen the contribution.

Formatting concerns

Figure 1 should be put after abstract.

3 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We thank the reviewer for questioning whether cross-modal synthetic text is clinically grounded despite modality differences and the lack of paired target-modality supervision. Please consider revisiting the Appendix in the Supplementary Material. Below, we provide our clarification on clinical validity, hallucination risk, and the contribution of synthetic cross-modal text.

Clinical validity and scope of cross-modal synthesis

SynTeX-FL is a training-time semantic augmentation framework that preserves source-supported evidence while reflecting modality-specific observability, rather than predicting reports for unobserved target-modality examinations. Because paired target-modality examinations are unavailable, we evaluate clinical finding preservation, modality-specific expression, and visibility constraints instead of reconstruction accuracy.

The qualitative results summarized in the table below, drawn from Figs. 3–17 in the Appendix, support this interpretation. The annotations in these figures were prepared based on clinician assessment: red arrows indicate the lesion or anatomical structure referenced in the report, red text marks clinically incorrect or inconsistent responses, and blue text marks clinically accurate and contextually appropriate responses. As shown in figures, SynTeX-FL preserves source-supported pathology while adapting it to the target modality.

Figure Original Modality Original-text Key Phrase Target Modality Synthesized-text Key Phrase
10 MRI “metastatic lesion in the right temporal lobe with brain edema” CT “hyperdense lesion ... surrounding hypodense areas consistent with vasogenic edema”
X-ray “not diagnostic for intracranial metastasis”
14 X-ray “bilateral fluffy infiltrates ... normal cardiac shadow ... non-cardiogenic pulmonary edema” MRI “bilateral areas of increased signal intensity; no evidence of cardiomegaly”
CT “bilateral ground-glass opacities; perihilar distribution”
8 MRI “high T2 and FLAIR signal in the occipital and posterior parietal subcortical white matter ... PRES” CT “subtle hypodensities in the occipital and posterior parietal white matter”
X-ray “white matter changes ... are not visualizable”
5 CT “ground glass ... peribronchial consolidation ... mild bronchiolectasis” MRI “increased T2 signal intensity ... peribronchial signal alterations”
X-ray “bilateral patchy opacities; peribronchial thickening; bronchiolectasis is not clearly visualized”
3 CT “narrowing of the left main bronchus to 5.7 mm” MRI “focal narrowing of the left main bronchus ... approximately 5.7 mm”
X-ray “left main bronchus ... cannot be reliably assessed on plain radiographs”

For example, in Fig. 14, X-ray “bilateral fluffy infiltrates” are expressed on MRI as “bilateral areas of increased signal intensity,” which is physically plausible because pulmonary edema increases lung water content and may produce high signal on fluid-sensitive MRI sequences. The absence of cardiomegaly is also preserved, supporting the non-cardiogenic interpretation. In Fig. 8, the source MRI finding of “high T2/FLAIR signal” is represented on CT as “subtle hypodensities” in the same occipital and posterior parietal white-matter regions. MRI sensitively depicts white-matter abnormalities through changes in tissue signal intensity, whereas CT reflects differences in X-ray attenuation, causing the same process to appear as more subtle low-density changes. In Fig. 5, the source CT findings of “ground-glass” and “peribronchial consolidation” are represented on X-ray as “bilateral patchy opacities” and “peribronchial thickening.” CT provides detailed cross-sectional images of pulmonary abnormalities, whereas X-ray projects three-dimensional thoracic structures onto a two-dimensional image, causing the same process to appear as broader changes in lung opacity and bronchial contours.

Although paired target-modality scans are unavailable, these examples provide qualitative evidence that SynTeX-FL preserves source-supported findings while expressing them in forms consistent with the physical and diagnostic observability of each target modality.

We also quantitatively assessed whether the synthesized reports follow modality-specific reporting conventions using PPL (Appendix Table 10 and Fig. 1). For each target modality, PPL was computed using a GPT-2 evaluator fine-tuned only on real reports from the corresponding modality. A synthesized CT, MRI, or X-ray report was therefore evaluated against the terminology and reporting patterns observed in authentic reports of that modality. The evaluator measured how naturally each term follows the preceding clinical context, and lower perplexity indicates closer alignment with real modality-specific medical language. This result provides quantitative support for the clinical linguistic plausibility of the synthesized reports.

We will add the qualitative analysis and clarify the modality-specific interpretation of PPL in Appendix.

Clinical consistency and hallucination

We reported complementary evaluations of hallucination risk and clinical consistency using clinician-recommended sensitivity and PPV, which assess diagnostic completeness and the reliability of positive findings (Appendix Table 11 and Fig. 2; Main Lines 303–305). SynTeX-FL outperforms TST-CycleGAN on both metrics, indicating better preservation of source-supported findings with fewer unsupported additions.

To further evaluate hallucination risk and clinical consistency on LLaVA-Med, we assessed 996 source cases across five prespecified clinical label categories: primary finding, anatomical localization, imaging appearance, severity, and additional findings. The 996 source cases were approximately evenly divided among five clinicians. Blinded to the generation method, each clinician evaluated the original report and all corresponding target-modality reports generated by NAST, TST-CycleGAN, and SynTeX-FL for their assigned cases under the same protocol. The clinicians annotated their assigned cases by labeling each finding as present or absent in the source report and in each corresponding generated target-modality report. We also report on the visibility-violation rate as a visibility-specific hallucination indicator, defined as the proportion of generated positive statements that refer to findings not assessable in the target modality. Clinicians additionally labeled whether each generated positive finding was assessable in the specified target modality. Metrics were micro-averaged over the five clinical-label categories across all reviewed cases. As shown in the table below, SynTeX-FL consistently achieves strong performance across all metrics, indicating reliable preservation of clinician-annotated findings with limited omissions and unsupported additions.

Metric Clinical-label Consistency
Accuracy ↑ Precision ↑ Recall ↑ F1 score ↑ Visibility Violation Rate ↓
NAST 72.2 70.5 70.8 70.6 18.4
TST-CycleGAN 79.1 80.1 73.9 76.9 14.5
SynTeX-FL 97.5 94.3 98.9 96.5 3.4

For downstream VQA evaluation, clinician-identified findings were used as reference findings to assess finding-level correctness (Appendix Table 13; examples in Figs. 3–17). The results show that SynTeX-FL more consistently preserves clinically relevant findings in its VQA responses without omission or unsupported addition.

We will add the clinical-label consistency protocol, results, and analysis to Appendix D.

Real-only modality-specific LoRA and synthetic-text ablation

To isolate the contribution of synthetic cross-modal text, we examined different synthetic weightings in Appendix Tables 8 and 9. At γ=1.5, the model performs best on both datasets. The last row of Main Table 5 corresponds to the setting without cross-modal text, in which cross-modal synthesis and its associated modality-specialized LoRA are jointly removed.

Following the reviewer’s suggestion, we conduct a real-only LoRA ablation on the LLaVA-Med and VQA-RAD datasets, where each modality-specialized LoRA is trained exclusively on real data from its corresponding modality without synthetic cross-modal text. This directly implements the requested modality-specific adapter baseline. All training settings are retained while only synthetic cross-modal text is removed. As shown in the table below, SynTeX-FL consistently outperforms the real-only LoRA across all evaluated metrics. These results suggest that synthetic cross-modal supervision provides useful complementary signals beyond standard modality-specific training, rather than primarily introducing noise. We will add this ablation as an additional row in Main Table 5, with only the Modality-specialized LoRA component enabled.

LLaVA-Med

Metric ROUGE-L METEOR CIDEr BLEU-1 BLEU-5
Real-only LoRA 0.3690 0.3398 0.5112 0.2884 0.1427
SynTeX-FL 0.4057 0.3727 0.5543 0.3309 0.1740

VQA-RAD

Metric Overall Open Closed
Real-only LoRA 65.76 52.04 73.26
SynTeX-FL 73.89 61.46 82.10

Taken together, the qualitative and clinician-based evaluations assess modality-specific observability, hallucination risk, and downstream VQA consistency, while the real-only LoRA ablation isolates the benefit of synthetic cross-modal supervision beyond modality-specific training.

\rule{0pt}{2.0em} We hope that the additional clinical evaluations, analyses, and ablation studies address the concerns raised. We will move Fig. 1 after the abstract and also welcome any further questions or discussion.

Authors · CommentOpenReview ↗

Thank you for your time

Dear Reviewer VWQW,

Thank you for taking the time to review our paper and for providing valuable feedback. As the discussion period deadline is approaching, we would appreciate any further comments or remaining concerns you may have. Your comments on the clinical grounding of cross-modal synthesis, modality-specific observability, hallucination risk, real-only adapter baselines, and limitations have greatly helped us strengthen the clinical evaluation and clarify the scope and contribution of our method.

Best,

The Authors

Authors · CommentOpenReview ↗

Request for Any Remaining Feedback

Dear Reviewer VWQW,

As the discussion period is approaching its deadline, we kindly ask whether you could review our response and share any remaining questions or concerns. We greatly appreciate your valuable feedback and would be happy to provide further clarification.

Best regards,

The Authors

Reviewer B498OpenReview ↗
Rating
3/6
Confidence
4/5
Quality
2/4
Clarity
3/4
Significance
2/4
Originality
2/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This work addresses the central challenge of cross-modal vertical federated learning for medical VQA where hospitals hold unimodal data (X-ray, CT, or MRI) without paired samples. The authors propose a two-stage framework: 1- cross-modal text synthesis using cycle-consistent adversarial transfer with quality-aware aggregation and 2 - modality-specialized LoRA fine-tuning with source-aware weighting. Claims are validated on LLaVA-Med and VQA-RAD benchmarks against eight FL baselines.

Strengths and weaknesses

The federated text synthesis formulation is conceptually elegant, and the modality-specialised aggregation shows some practical promise. Therefore, the claims of the paper regarding (no paired multimodal data) are somewhat misleading, where each client still requires paired image-text data for their own modality, which is the easier half of the problem. The privacy analysis is largely lacks detail. The clinical validation with five experts lacks any quantitative unspecific, and the domain adaptation comparison uses SEA, a time-series method ill-suited for medical imaging, making it a bit of a strawman.

Questions

1- how exactly does the discriminator score in quality-aware aggregation not leak sensitive information about client data distributions, and have you formally analysed privacy guarantees beyond simply noting that (secure aggregation or differential privacy can be incorporated)?

2- the synthesis transfer module S is supposedly frozen and shared yet Table 5 ablates (image transfer), does this imply S was trained centrally on pooled data and if so doesn't this violate the core vertical FL premise?

3- you mention 5 clinical experts reviewed synthetic reports but provide no inter-rater reliability scores, no number of reports reviewed, and no quantitative metrics for diagnostic finding preservation, can you provide these?

Limitations

The authors mention limitations in Appendix G but the main text doesn't discuss the single-dataset limitation, the small number of clients (6), or the fact that all clients use the same backbone architecture. The ethical implications of generating synthetic medical reports, potential hallucination of critical findings, are not seriously addressed.

Formatting concerns

none

3 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We thank the reviewer for recognizing the conceptual elegance of our federated text synthesis and the practical promise of modality-specialized aggregation. Please also consider revisiting the Appendix in the Supplementary Material. Below, we provide our clarification on the paired-data claim, domain-adaptation baselines, discriminator-score privacy, synthesis-module training, clinical validation, and limitations.

Clarification of the “paired multimodal data”

We acknowledge that the expressions “paired multimodal samples” (main paper, Line 7) and “paired multimodal data” (main paper, Line 149) may be misleading. In the revised manuscript, we will replace both expressions with “same-patient paired samples across medical imaging modalities”.

Domain-adaptation baselines

The domain adaptation comparison in Main Table 3 does not use SEA’s time-series-specific input-processing architecture. Instead, we adopted its core domain-adaptation mechanism for aligning representations across modalities in feature space. Moreover, the comparison is not limited to SEA, as it also includes CAF, a visual feature-level domain adaptation method designed for image data rather than time-series inputs. Accordingly, Main Table 3 can be interpreted as a controlled comparison between feature-space alignment and text-space transfer (main paper, Lines 298–300).

Privacy of the discriminator score and scope of the privacy claim

The discriminator score used in quality-aware aggregation is a client-level reconstruction quality statistic indicating how well the text generated by the local reconstruction model matches the distribution of real medical reports. It is not trained to predict patient- or disease-specific attributes. The shared score is computed by averaging sample-level discriminator outputs bounded between 0 and 1 over the client’s entire local dataset. Therefore, the shared score substantially limits direct exposure of sensitive information about individual patients or specific client data distributions.

Our privacy claim is limited to keeping raw data local, while only model updates and an aggregated client-level quality score are shared. We do not claim formal differential privacy or resistance to update-based inference attacks. In the revised manuscript, we will clarify the meaning and computation of the discriminator score and make the scope of our privacy claim explicit.

Clarification of the Ablation Study in Table 5

The synthesis transfer module S is not trained centrally on pooled data. Each client keeps S frozen during local training and trains its reconstruction transfer module R using local image–report pairs. The server aggregates the R weights from clients of the same modality, and the aggregated R is redistributed as that modality’s S in the next round. Thus, S is updated indirectly without sharing raw data.

We believe this confusion may have arisen because the ablation settings in Main Table 5 were not clearly separated by horizontal lines. Main Table 5 does not include an “image transfer” ablation. The “Image” ablation removes the source-modality image input to both S and R, while the federated learning process using S and R remains otherwise unchanged. In this setting, S is still updated indirectly without sharing raw data. The “Transfer” ablation removes cross-modal text transfer entirely and corresponds to the FedAvg setting (main paper, Lines 316–317). This setting likewise involves no centralized training and does not violate the vertical FL premise. We will revise the table formatting to avoid this ambiguity.

Clinical evaluation protocol and quantitative diagnostic preservation

We assessed 996 source cases from the LLaVA-Med dataset across five prespecified clinical label categories: primary finding, anatomical localization, imaging appearance, severity, and additional findings. The 996 source cases were approximately evenly divided among five clinicians. Blinded to the generation method, each clinician evaluated the original report and all corresponding target-modality reports generated by NAST, TST-CycleGAN, and SynTeX-FL for their assigned cases under the same protocol. The clinicians annotated their assigned cases by labeling each finding as present or absent in the source report and in each corresponding generated target-modality report. Because each report pair was evaluated by one clinician, inter-rater reliability could not be computed.

Regarding quantitative evaluation of diagnostic finding preservation, we reported the clinician-recommended metrics of sensitivity and PPV (Appendix Table 11; main paper, Lines 303–305) to assess diagnostic completeness and the reliability of positive findings, respectively. SynTeX-FL outperforms TST-CycleGAN on both metrics (98.52/98.20 vs. 82.64/81.09), indicating better preservation of source-supported findings with fewer unsupported additions.

To further quantify diagnostic preservation, we additionally report accuracy, precision, recall, F1 score, and the visibility-violation rate using the same clinician annotations. The visibility-violation rate is defined as the proportion of generated positive statements referring to findings not assessable in the target modality. Clinicians additionally labeled whether each generated positive finding was assessable in the specified target modality. Metrics were micro-averaged over the five clinical-label categories across all reviewed cases. As shown in the table below, SynTeX-FL consistently achieves strong performance across all metrics, indicating reliable preservation of clinician-annotated findings with limited omissions and unsupported additions.

Metric Clinical-label Consistency
Accuracy ↑ Precision ↑ Recall ↑ F1 score ↑ Visibility Violation Rate ↓
NAST 72.2 70.5 70.8 70.6 18.4
TST-CycleGAN 79.1 80.1 73.9 76.9 14.5
SynTeX-FL 97.5 94.3 98.9 96.5 3.4

For downstream VQA evaluation, clinician-identified findings were used as reference findings to assess finding-level correctness (Appendix Table 13; examples in Figs. 3–17). The annotations in these figures were prepared based on clinician assessment: red arrows indicate the lesion or anatomical structure referenced in the report, red text marks clinically incorrect or inconsistent responses, and blue text marks clinically accurate and contextually appropriate responses. SynTeX-FL achieves 52.8, compared with 47.2 for FedKIM and 42.1 for FedAvg, indicating more consistent preservation of clinically relevant findings in VQA responses with fewer omissions and unsupported additions.

We will add the clinician annotation protocol, reviewed sample size, inter-rater reliability limitation, and clinical-label consistency results to the Appendix.

Limitations

Our evaluation uses two representative medical VQA datasets, LLaVA-Med and VQA-RAD, obtained from multiple institutions. We also already evaluated a nine-client setting in addition to the primary six-client configuration (main paper, Lines 254–256; Appendix B, Tables 1–4), demonstrating the robustness of SynTeX-FL across client counts. As in prior FL methods, we used the same VQA backbone across clients for weight sharing and aggregation.

SynTeX-FL is not designed to predict the actual diagnostic reports of unobserved CT or MRI examinations. Rather, its synthetic reports provide auxiliary information intended to improve downstream VQA performance, not standalone clinical reports. It is a training-time semantic augmentation framework that preserves source-supported evidence while reflecting modality-specific observability. Within this scope, the clinician-annotated quantitative evaluations of diagnostic finding preservation described above and the qualitative results in Appendix Figs. 3–17 show that SynTeX-FL preserves critical findings and limits unsupported additions, thereby reducing the risk of hallucinating critical findings. In these clinician-assessed figures, red arrows indicate the referenced lesion or anatomical structure, red text denotes clinically incorrect or inconsistent responses, and blue text denotes clinically accurate and contextually appropriate responses. Using synthetic reports only as auxiliary information for VQA reduces the risks associated with their direct clinical use, although prospective clinical validation and formal privacy safeguards remain necessary.

\rule{0pt}{2.0em} We appreciate the reviewer’s careful feedback and hope that our clarifications on paired data, domain-adaptation baselines, discriminator-score privacy, ablation settings, clinical validation, and limitations address the concerns raised. We welcome any further questions or discussion.

Reviewer B498 · CommentOpenReview ↗

I appreciate the effort put into the response. However, the rebuttal falls short of elevating the paper above the threshold of concern. The contribution is still borderline reject and my initial score will not change.

Authors · CommentOpenReview ↗

Thank You for Your Feedback

Dear Reviewer B498,

Thank you for taking the time to consider our rebuttal and for providing your candid assessment. We respect your decision to maintain the original rating. We nevertheless appreciate your feedback, which has helped us more clearly define the scope of our claims and strengthen the presentation of our clinical evaluation, privacy considerations, and limitations.

Best,

The Authors

Reviewer V9a1OpenReview ↗
Rating
4/6
Confidence
3/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper studies federated medical VQA under a cross-modal setting, where different clients may hold data from different imaging modalities. The main idea is to improve multimodal reasoning without sharing raw clinical data by generating synthetic textual representations from medical images, using modality-specific LoRA modules for different imaging domains, and aggregating client updates with quality-aware and source-aware weighting.

Strengths and weaknesses

The paper addresses an important and practical problem. The idea of combining federated learning with cross-modal text transfer is meaningful. It provides a way to exploit complementary modality information while preserving data privacy. The modality-specific LoRA design is reasonable for handling modality heterogeneity.

I have some concerns as follow:

  1. In Table 2, since the target task is medical VQA, the paper should include comparisons with dedicated medical VQA models, such as LLaVA-Med [1], Med-MoE [2], and AMiF [3]. Such comparisons are needed to judge whether the proposed FL framework is competitive with existing medical VQA systems.
  2. It is unclear what LLM or generative model is used to produce the synthetic reports. From Figure 3, the synthetic report seems to be generated after only an attention layer, which does not appear sufficient to perform text generation.
  3. The text synthesis objective is similar to adversarial training or GAN-style optimization. While the discriminator loss may make the reconstructed text look realistic, it does not guarantee clinical correctness or faithfulness to the image. More evaluation is needed to show that the synthesized text does not introduce medical hallucinations.
  4. The method seems more like an application of existing techniques, text synthesis, LoRA and modality-specific adapter in the medical VQA FL setting. [1] LLaVA-Med: Training a Large Language-and-Vision Assistant for Biomedicine in One Day. [2] Med-MoE: Mixture of Domain-Specific Experts for Lightweight Medical Vision-Language Models. [3] Alignment, Mining and Fusion: Representation Alignment with Hard Negative Mining and Selective Knowledge Fusion for Medical Visual Question Answering.
Questions

Please see the weaknesses above.

Limitations

yes

Final justification

The authors have provided additional comparative experiments and clarified the design of each model component. These results and explanations are convincing and have addressed most of my concerns.

Formatting concerns

No paper formatting concerns.

5 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We thank the reviewer for recognizing the importance of cross-modal vertical FL, cross-modal text transfer, and modality-specific LoRA. Please also consider revisiting the Appendix in the Supplementary Material. We address the four concerns below.

Comparison with other medical VQA systems

SynTeX-FL is designed for cross-modal vertical FL, so our experiments focus on FL methods, including medical-domain methods such as FedMedVLP [33] and FedKIM [50]. A direct comparison between SynTeX-FL and centrally trained medical VQA models would not be appropriate; therefore, we reported a centrally trained model as an upper bound in Appendix F. To further address the reviewer’s concern, we conduct an additional comparison on the VQA-RAD dataset by using LLaVA-Med [1], Med-MoE [2], and AMiF [3] as VQA backbones for two strong FL methods, IOS [53] and FedTGP [60], and comparing these configurations with SynTeX-FL. As shown in the table below, SynTeX-FL with its original LLaVA backbone outperforms FedTGP and IOS even when these competing FL methods are equipped with medical-domain VQA backbones. These results demonstrate the competitiveness of SynTeX-FL in the cross-modal vertical FL setting without relying on a specialized medical VQA architecture. We will include references [2, 3], these comparison results, and the corresponding analysis in the Appendix.

VQA Backbone FL Method Overall Open Closed
LLaVA-Med [1] FedTGP [60] 70.52 57.21 78.56
IOS [53] 70.66 57.82 78.93
Med-MoE [2] FedTGP [60] 70.17 56.95 79.25
IOS [53] 70.95 57.19 80.17
AMiF [3] FedTGP [60] 71.51 58.35 80.34
IOS [53] 72.08 58.87 80.82
LLaVA [32] SynTeX-FL 73.89 61.46 82.10

Architecture of the synthetic report generator

The cross-modal text transfer module is built on a standard Transformer architecture [47] (main paper, Lines 155–157). Figure 3 provides a simplified illustration of this module, which may have made it appear that the synthetic report is generated after only a single attention layer. Specifically, the cross-modal text transfer module consists of six Transformer blocks, each employing multi-head attention with 12 attention heads. The figure also omits tokenization, detokenization, and final report generation, where the fused representation is projected to vocabulary logits and decoded into the target-modality report. We acknowledge that this simplified presentation may have caused confusion. In the revised version, we will update Figure 3 and the corresponding description.

Clinical faithfulness and hallucination risk

SynTeX-FL is a training-time semantic augmentation framework that preserves source-supported evidence while reflecting modality-specific observability, rather than predicting reports for unobserved target-modality examinations. Because paired target-modality examinations are unavailable, we evaluate clinical finding preservation, modality-specific expression, and visibility constraints instead of reconstruction accuracy.

The qualitative results summarized in the table below, drawn from Figs. 3–17 in the Appendix, support this interpretation. The annotations in these figures were prepared based on clinician assessment: red arrows indicate the lesion or anatomical structure referenced in the report, red text marks clinically incorrect or inconsistent responses, and blue text marks clinically accurate and contextually appropriate responses. As shown in figures, SynTeX-FL preserves source-supported pathology while adapting it to the target modality.

Figure Original Modality Original-text Key Phrase Target Modality Synthesized-text Key Phrase
Fig. 10 MRI “metastatic lesion in the right temporal lobe with brain edema” CT “hyperdense lesion ... surrounding hypodense areas consistent with vasogenic edema”
X-ray “not diagnostic for intracranial metastasis”
Fig. 14 X-ray “bilateral fluffy infiltrates ... normal cardiac shadow ... non-cardiogenic pulmonary edema” MRI “bilateral areas of increased signal intensity; no evidence of cardiomegaly”
CT “bilateral ground-glass opacities; perihilar distribution”
Fig. 8 MRI “high T2 and FLAIR signal in the occipital and posterior parietal subcortical white matter ... PRES” CT “subtle hypodensities in the occipital and posterior parietal white matter”
X-ray “white matter changes ... are not visualizable”
Fig. 5 CT “ground glass ... peribronchial consolidation ... mild bronchiolectasis” MRI “increased T2 signal intensity ... peribronchial signal alterations”
X-ray “bilateral patchy opacities; peribronchial thickening; bronchiolectasis is not clearly visualized”
Fig. 3 CT “narrowing of the left main bronchus to 5.7 mm” MRI “focal narrowing of the left main bronchus ... approximately 5.7 mm”
X-ray “left main bronchus ... cannot be reliably assessed on plain radiographs”

For example, in Fig. 8, the source MRI finding of “high T2/FLAIR signal” is represented on CT as “subtle hypodensities” in the same occipital and posterior parietal white-matter regions. MRI sensitively depicts white-matter abnormalities through changes in tissue signal intensity, whereas CT reflects differences in X-ray attenuation, causing the same process to appear as more subtle low-density changes.

In Fig. 5, the source CT findings of “ground-glass” and “peribronchial consolidation” are represented on X-ray as “bilateral patchy opacities” and “peribronchial thickening.” CT provides detailed cross-sectional images of pulmonary abnormalities, whereas X-ray projects three-dimensional thoracic structures onto a two-dimensional image, causing the same process to appear as broader changes in lung opacity and bronchial contours.

Although paired target-modality scans are unavailable, these examples provide qualitative evidence that SynTeX-FL preserves source-supported findings while expressing them in forms consistent with the physical and diagnostic observability of each target modality.

We also evaluated hallucination risk and clinical faithfulness using clinician-recommended sensitivity and PPV, which assess diagnostic completeness and the reliability of positive findings (Appendix Table 11 and Fig. 2; Main Lines 303–305). SynTeX-FL outperforms TST-CycleGAN on both metrics, indicating better preservation of source-supported findings with fewer unsupported additions.

To further evaluate hallucination risk and clinical faithfulness on LLaVA-Med, we assessed 996 source cases across five prespecified clinical label categories: primary finding, anatomical localization, imaging appearance, severity, and additional findings. The 996 source cases were approximately evenly divided among five clinicians. Blinded to the generation method, each clinician evaluated the original report and all corresponding target-modality reports generated by NAST, TST-CycleGAN, and SynTeX-FL for their assigned cases under the same protocol. The clinicians annotated their assigned cases by labeling each finding as present or absent in the source report and in each corresponding generated target-modality report. We further report the visibility-violation rate as a visibility-specific hallucination indicator, defined as the proportion of generated positive statements that refer to findings not assessable in the target modality. Clinicians additionally labeled whether each generated positive finding was assessable in the specified target modality. Metrics were micro-averaged over the five clinical-label categories across all cases. As shown in the table below, SynTeX-FL consistently achieves strong performance across all metrics, indicating reliable preservation of clinician-annotated findings with limited omissions and unsupported additions.

Metric Clinical-label Consistency
Accuracy ↑ Precision ↑ Recall ↑ F1 score ↑ Visibility Violation Rate ↓
NAST 72.2 70.5 70.8 70.6 18.4
TST-CycleGAN 79.1 80.1 73.9 76.9 14.5
SynTeX-FL 97.5 94.3 98.9 96.5 3.4

For downstream VQA evaluation, clinician-identified findings were used as reference findings to assess finding-level correctness (Appendix Table 13; examples in Figs. 3–17). SynTeX-FL achieves the highest finding-level correctness among the compared methods, indicating more consistent preservation of clinically relevant findings in VQA responses without omissions or unsupported additions.

We will add the clinical-label consistency protocol, results, and analysis, together with the qualitative analysis, to the Appendix.

Methodological novelty

The core contribution of SynTeX-FL is to enable medical VQA models to use information from other imaging modalities in cross-modal vertical FL. Its cross-modal text transfer selectively freezes or trains modules according to each client’s modality and supervises synthesis by reconstructing the source-modality report, while quality-aware aggregation downweights updates associated with unreliable synthetic samples to improve training stability. In addition, source-aware weighting balances modality-specific updates derived from real and synthetic reports. Together, these components improve medical VQA performance by enabling SynTeX-FL to effectively use complementary clinical information from other medical imaging modalities in low-resource, modality-biased cross-modal vertical FL settings.

We hope that the additional comparisons, clarifications, clinical evaluations, and novelty discussion address the concerns raised. We welcome any further questions or discussion.

Authors · CommentOpenReview ↗

Thank you for your time

Dear Reviewer V9a1,

Thank you for taking the time to review our paper and for providing valuable feedback. As the discussion period deadline is approaching, we would appreciate any further comments or remaining concerns you may have. Your comments on the medical VQA comparisons, synthetic report generation, clinical faithfulness, and methodological contribution have greatly helped us strengthen our evaluation and clarify the paper.

Best,

The Authors

Authors · CommentOpenReview ↗

Request for Any Remaining Feedback

Dear Reviewer V9a1,

As the discussion period is approaching its deadline, we kindly ask whether you could review our response and share any remaining questions or concerns. We greatly appreciate your valuable feedback and would be happy to provide further clarification.

Best regards,

The Authors

Comments on the paper

1 comment
Authors · CommentOpenReview ↗

Discussion Closing Remarks

Dear Area Chair and Reviewers,

We sincerely thank all reviewers and the Area Chair for their time, effort, and constructive feedback. We are pleased that Reviewer V9a1 found that most concerns had been addressed and raised the score after considering our rebuttal. We are also grateful that Reviewer VWQW reconsidered the additional evidence and raised the score.

Our rebuttal and planned revisions have been substantially strengthened by the reviewers’ suggestions:

  • Reviewer V9a1 – Added comparisons involving dedicated medical VQA backbones, clarified the architecture of the synthetic-report generator, expanded the clinical-faithfulness and hallucination analyses, and strengthened the discussion of methodological novelty.

  • Reviewer B498 – Clarified the absence of same-patient paired samples across medical imaging modalities, the scope of our privacy claim and discriminator-score sharing, the decentralized training procedure of the synthesis module, the clinical evaluation protocol, and the limitations of the proposed framework.

  • Reviewer VWQW – Added clinician-based clinical-label consistency evaluation, qualitative clinical validation, and a real-only modality-specific LoRA baseline.

Taken together, we believe that our rebuttal and planned revisions directly address the central concerns raised by the Area Chair and reviewers and substantially strengthen the clinical validation, experimental evaluation, and methodological presentation of our work.

As authors cannot participate in the forthcoming Phase 3 reviewer–AC discussion, we respectfully hope that the Area Chair and reviewers will continue their careful discussion of the additional evidence. We also hope that these new results and clarifications will be carefully considered when assessing whether the raised concerns have been adequately addressed.

Best regards,

The Authors

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Missing a submission?

Loading the discussion…