VCR: Learning Valid Contextual Representation for Incomplete Wearable Signals
Yuxuan Weng, Wenhan Luo, Qijia Shao
Abstract. Wearable devices enable continuous health monitoring from multimodal signals, but real-world deployment is hindered by limited labeled data and pervasive sensor incompleteness. While large-scale self-supervised pretraining reduces label dependence, most existing methods assume full modality availability during downstream inference. Current approaches for handling modality missingness often reconstruct entire absent signals, which can encourage hallucinating modality-specific details that are not inferable from the observed sensor signals and degrade robustness. We propose VCR, a self-supervised framework that learns to extract valid representations robust to modality missingness. VCR employs an orthogonal tokenizer to enforce strict orthogonal disentanglement by rectifying latent manifolds and applying a geometric projection, separating each modality into shared semantics and modality-specific residuals. This design preserves complete information integrity while serving as a structural foundation for robust learning under modality missingness. The resulting tokens are processed by a missing-aware mixture-of-experts backbone that adapts to varying patterns of modality availability. By constraining the objective to reconstruct only the inferable shared components of missing modalities, VCR effectively mitigates hallucination-like completion of non-inferable modality-specific details. Across multiple health monitoring tasks, VCR consistently improves performance and robustness under full, single-missing, and multiple-missing modality settings compared with strong supervised and self-supervised baselines. Our code is available at https://github.com/yuxuanweng/VCR.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 4 reviews · OpenReview
Updated 25 Nov 2026, 03:42 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
(a) Scientific Claims/Findings
The paper proposes VCR, a self-supervised framework designed to learn representations from multimodal wearable physiological signals that are robust to sensor/modality missingness. The core claim is that current missing-modality approaches that attempt to reconstruct entire absent signals are prone to hallucinating modality-specific details that cannot be logically inferred from the available sensors. To address this, VCR uses an orthogonal tokenizer to geometrically decompose features into modality-shared semantics and modality-specific residuals, paired with a missingness-aware MoE backbone. The training objective is restricted to reconstructing only the shared components of missing modalities, thereby avoiding the hallucination of unobservable specific details.
(b) Strengths
- [w1kp] Strong Motivation: The problem of modality missingness in continuous wearable sensing is a relevant and practical real-world challenge, especially for generalizability across various commerical wearable devices that may not have full sensor suites across companies.
- [w1kp, 2HPX, Myf8] Methodological Design: The combination of strict geometric orthogonal disentanglement and a missingness-aware MoE provides a novel and interesting architectural approach to the problem with a compelling inductive bias.
- [4cWz, Myf8] Extensive Downstream Evaluation: The framework is evaluated across a diverse set of relevant health monitoring tasks (emotion recognition, activity recognition, sleep staging, and VO2 prediction) covering single and multiple modality dropout scenarios.
(c) Weaknesses
- [w1kp , 4cWz, 2HPX] Problem Framing: Further sentences and citations should be used to justify modality missingness problem. For example, there is lack of sensor availability across commerical devices, e.g. Oura ring does not have ECG, EDA, Altimeter sensors, but the Google's Fitbit Charge has all three, but the Apple watch only has the ECG and Altimeter. Additionally, the framing makes it unclear if the focus is on pre-training with missing modalities, or evaluation.
- [w1kp, 2HPX] Additional Missingness Modes: There are other modes of missingness that include intermittemnt drop outs for a given modality, but this is not evaluated.
- [w1kp, 2HPX, Myf8] Overclaimed Assertions: Some of the theoretical guarantees may not be guaranteed, please see Myf8 for more details. Additionally w1kp and 2HPX note that the masked reconstruction leading hallucination assertion is not fully justified and is not well explained.
(d) Recommendations
Please address the weaknesses above and from each reviewer during the rebuttal.
Final justification
This paper addresses a strong real-world problem. Such missingness is not commonly seen within academic dataset settings, but is definitely seen within the large-scale industry wearable settings. It does so with a theoretically-grounded methodology and diverse downstream evaluations. Despite initial concerns on framing, during the rebuttal was able to address all concerns from the reviewers, running new experiments on additional missingness modes and clarifying their claims, without excessively downgrading them, thereby successfully raising their scores to all within the accept range. I strongly encourage the authors the emphasize the additional missingness experiments within the final camera-ready, as this has helped helped clarify many of initial reviewer concerns.
Read meta-review
Meta-review
(a) Scientific Claims/Findings
The paper proposes VCR, a self-supervised framework designed to learn representations from multimodal wearable physiological signals that are robust to sensor/modality missingness. The core claim is that current missing-modality approaches that attempt to reconstruct entire absent signals are prone to hallucinating modality-specific details that cannot be logically inferred from the available sensors. To address this, VCR uses an orthogonal tokenizer to geometrically decompose features into modality-shared semantics and modality-specific residuals, paired with a missingness-aware MoE backbone. The training objective is restricted to reconstructing only the shared components of missing modalities, thereby avoiding the hallucination of unobservable specific details.
(b) Strengths
- [w1kp] Strong Motivation: The problem of modality missingness in continuous wearable sensing is a relevant and practical real-world challenge, especially for generalizability across various commerical wearable devices that may not have full sensor suites across companies.
- [w1kp, 2HPX, Myf8] Methodological Design: The combination of strict geometric orthogonal disentanglement and a missingness-aware MoE provides a novel and interesting architectural approach to the problem with a compelling inductive bias.
- [4cWz, Myf8] Extensive Downstream Evaluation: The framework is evaluated across a diverse set of relevant health monitoring tasks (emotion recognition, activity recognition, sleep staging, and VO2 prediction) covering single and multiple modality dropout scenarios.
(c) Weaknesses
- [w1kp , 4cWz, 2HPX] Problem Framing: Further sentences and citations should be used to justify modality missingness problem. For example, there is lack of sensor availability across commerical devices, e.g. Oura ring does not have ECG, EDA, Altimeter sensors, but the Google's Fitbit Charge has all three, but the Apple watch only has the ECG and Altimeter. Additionally, the framing makes it unclear if the focus is on pre-training with missing modalities, or evaluation.
- [w1kp, 2HPX] Additional Missingness Modes: There are other modes of missingness that include intermittemnt drop outs for a given modality, but this is not evaluated.
- [w1kp, 2HPX, Myf8] Overclaimed Assertions: Some of the theoretical guarantees may not be guaranteed, please see Myf8 for more details. Additionally w1kp and 2HPX note that the masked reconstruction leading hallucination assertion is not fully justified and is not well explained.
(d) Recommendations
Please address the weaknesses above and from each reviewer during the rebuttal.
Final justification
This paper addresses a strong real-world problem. Such missingness is not commonly seen within academic dataset settings, but is definitely seen within the large-scale industry wearable settings. It does so with a theoretically-grounded methodology and diverse downstream evaluations. Despite initial concerns on framing, during the rebuttal was able to address all concerns from the reviewers, running new experiments on additional missingness modes and clarifying their claims, without excessively downgrading them, thereby successfully raising their scores to all within the accept range. I strongly encourage the authors the emphasize the additional missingness experiments within the final camera-ready, as this has helped helped clarify many of initial reviewer concerns.
7 comments
Experimental Results [Part 2/4]
Table B. Temporal drop results for supervised methods
Each cell: FlexMoE / MAESTRO / Ours FT. Best results are bold.
| Missing | Drop | WESAD F₁↑ | AAUWSS F₁↑ | DALIA F₁↑ | WEEE MAE↓ |
|---|---|---|---|---|---|
| PPG | 20% | .582±.030/ .578±.012/.622±.056 | .231±.023/ .270±.011/.289±.018 | .714±.008/ .730±.003/.763±.006 | 3.147±.207/ 3.680±.434/2.690±.107 |
| 50% | .586±.029/ .574±.018/.627±.064 | .219±.019/ .261±.015/.277±.020 | .714±.007/ .731±.002/.768±.007 | 3.394±.260/ 3.776±.417/2.800±.137 | |
| EDA | 20% | .570±.028/ .559±.016/.601±.054 | .230±.019/ .276±.006/.291±.016 | .721±.009/ .723±.005/.765±.008 | 3.031±.202/ 3.785±.476/2.613±.096 |
| 50% | .548±.023/ .527±.011/.563±.049 | .226±.013/ .262±.014/.284±.016 | .726±.009/ .713±.008/.767±.010 | 2.990±.176/ 4.078±.533/2.643±.100 | |
| ACC | 20% | .568±.028/ .581±.005/.621±.053 | .238±.025/ .270±.005/.293±.017 | .705±.007/ .703±.006/.750±.008 | 2.905±.156/ 3.423±.399/2.647±.097 |
| 50% | .555±.026/ .589±.016/.615±.029 | .239±.020/ .252±.011/.288±.020 | .649±.039/ .638±.009/.724±.010 | 2.820±.172/ 3.194±.358/2.662±.097 | |
| TEMP | 20% | .591±.036/ .575±.012/.619±.064 | .241±.023/ .274±.002/.294±.015 | .701±.005/ .713±.004/.748±.010 | 3.029±.203/ 3.756±.459/2.596±.083 |
| 50% | .604±.031/ .571±.021/.621±.070 | .233±.016/ .274±.005/.297±.017 | .680±.007/ .689±.010/.721±.010 | 3.035±.213/ 4.012±.496/2.556±.064 | |
| PPG+EDA | 20% | .573±.027/ .566±.016/.604±.056 | .227±.027/ .273±.009/.288±.018 | .724±.008/ .730±.006/.770±.006 | 3.111±.209/ 3.832±.473/2.667±.108 |
| 50% | .551±.019/ .528±.017/.565±.056 | .221±.015/ .260±.019/.264±.019 | .730±.011/ .720±.011/.782±.006 | 3.324±.232/ 4.270±.537/2.805±.149 | |
| PPG+ACC | 20% | .570±.027/ .594±.011/.631±.052 | .236±.020/ .275±.005/.291±.017 | .704±.005/ .714±.007/.756±.010 | 3.000±.181/ 3.414±.379/2.695±.113 |
| 50% | .559±.020/ .635±.010/.628±.042 | .221±.012/ .282±.014/.281±.020 | .638±.067/ .665±.005/.730±.011 | 3.159±.243/ 3.278±.335/2.898±.174 | |
| PPG+TEMP | 20% | .594±.032/ .582±.013/.626±.068 | .232±.023/ .269±.010/.291±.017 | .705±.006/ .717±.007/.754±.008 | 3.134±.212/ 3.795±.456/2.658±.093 |
| 50% | .611±.033/ .591±.022/.633±.088 | .204±.019/ .254±.011/.279±.018 | .681±.007/ .700±.006/.734±.013 | 3.332±.279/ 4.167±.476/2.727±.094 | |
| EDA+ACC | 20% | .561±.025/ .566±.016/.607±.047 | .236±.020/ .268±.004/.291±.016 | .714±.006/ .710±.004/.757±.010 | 2.875±.152/ 3.542±.441/2.611±.092 |
| 50% | .531±.027/ .541±.022/.558±.035 | .244±.018/ .242±.011/.284±.016 | .672±.046/ .655±.009/.736±.012 | 2.699±.143/ 3.421±.470/2.613±.090 | |
| EDA+TEMP | 20% | .585±.037/ .560±.014/.608±.059 | .238±.022/ .276±.004/.292±.016 | .710±.010/ .714±.006/.753±.008 | 3.011±.201/ 3.924±.496/2.584±.085 |
| 50% | .577±.040/ .529±.019/.579±.049 | .236±.019/ .273±.004/.285±.018 | .683±.017/ .678±.006/.726±.012 | 3.012±.210/ 4.603±.591/2.569±.084 | |
| ACC+TEMP | 20% | .583±.034/ .578±.017/.624±.057 | .245±.021/ .267±.005/.295±.015 | .700±.004/ .705±.007/.740±.009 | 2.899±.166/ 3.513±.410/2.608±.085 |
| 50% | .589±.037/ .564±.024/.626±.052 | .223±.016/ .250±.006/.291±.020 | .620±.036/ .629±.010/.695±.010 | 2.782±.163/ 3.380±.362/2.601±.065 | |
| PPG+EDA+ACC | 20% | .559±.024/ .573±.016/.613±.046 | .231±.018/ .276±.006/.291±.019 | .715±.004/ .719±.006/.766±.007 | 2.964±.170/ 3.560±.416/2.672±.110 |
| 50% | .526±.016/ .568±.021/.579±.042 | .240±.013/ .265±.020/.274±.019 | .656±.067/ .688±.004/.750±.011 | 2.888±.189/ 3.479±.441/2.781±.155 | |
| PPG+EDA+TEMP | 20% | .588±.032/ .559±.018/.610±.058 | .231±.025/ .274±.009/.286±.015 | .710±.007/ .723±.006/.761±.010 | 3.086±.221/ 3.966±.492/2.624±.097 |
| 50% | .590±.033/ .540±.026/.590±.056 | .217±.016/ .263±.009/.263±.020 | .681±.017/ .692±.013/.745±.014 | 3.269±.250/ 4.876±.586/2.667±.121 | |
| PPG+ACC+TEMP | 20% | .588±.030/ .591±.003/.629±.057 | .236±.018/ .273±.005/.293±.016 | .698±.002/ .710±.004/.747±.010 | 2.952±.182/ 3.528±.403/2.667±.099 |
| 50% | .601±.036/ .622±.019/.638±.059 | .206±.010/ .270±.010/.287±.016 | .609±.059/ .664±.012/.710±.013 | 3.059±.214/ 3.351±.292/2.838±.114 | |
| EDA+ACC+TEMP | 20% | .577±.030/ .564±.009/.610±.051 | .242±.018/ .268±.006/.291±.014 | .707±.009/ .707±.002/.747±.008 | 2.895±.167/ 3.657±.446/2.571±.084 |
| 50% | .558±.032/ .528±.017/.585±.040 | .244±.015/ .242±.008/.287±.015 | .681±.022/ .658±.010/.713±.010 | 2.684±.162/ 3.742±.494/2.487±.059 | |
| PPG+EDA+ACC+TEMP | 20% | .581±.032/ .575±.013/.619±.054 | .236±.015/ .276±.003/.291±.015 | .711±.006/ .721±.003/.758±.007 | 2.937±.169/ 3.657±.440/2.624±.095 |
| 50% | .574±.021/ .589±.009/.612±.040 | .239±.008/ .280±.007/.290±.015 | .669±.044/ .713±.009/.745±.011 | 2.891±.181/ 3.765±.458/2.622±.099 |
Experimental Results [Part 3/4]
Table C. Temporal drop results for SSL methods
Each cell: LSM2 / Ours LP. Best results are bold.
| Missing | Drop | WESAD F₁↑ | AAUWSS F₁↑ | DALIA F₁↑ | WEEE MAE↓ |
|---|---|---|---|---|---|
| PPG | 20% | .597±.004/ .626±.051 | .270±.002/ .278±.011 | .716±.004/ .755±.003 | 3.646±.077/ 2.638±.062 |
| 50% | .592±.001/ .628±.050 | .261±.004/ .261±.007 | .709±.003/ .759±.006 | 3.747±.222/ 2.703±.099 | |
| EDA | 20% | .572±.011/ .610±.046 | .248±.002/ .303±.009 | .719±.003/ .761±.004 | 3.653±.067/ 2.585±.056 |
| 50% | .530±.015/ .578±.040 | .229±.004/ .298±.022 | .718±.005/ .770±.007 | 3.824±.282/ 2.587±.065 | |
| ACC | 20% | .602±.010/ .629±.050 | .268±.001/ .294±.004 | .715±.001/ .739±.008 | 3.560±.099/ 2.640±.051 |
| 50% | .598±.012/ .620±.060 | .268±.003/ .289±.002 | .713±.003/ .701±.017 | 3.571±.129/ 2.692±.047 | |
| TEMP | 20% | .607±.008/ .626±.050 | .278±.002/ .295±.005 | .717±.005/ .751±.005 | 3.648±.167/ 2.577±.064 |
| 50% | .623±.021/ .624±.052 | .276±.004/ .293±.006 | .714±.008/ .736±.006 | 3.791±.331/ 2.545±.083 | |
| PPG+EDA | 20% | .571±.012/ .616±.050 | .249±.003/ .286±.011 | .718±.002/ .765±.004 | 3.705±.130/ 2.609±.055 |
| 50% | .532±.007/ .580±.045 | .227±.002/ .261±.008 | .718±.005/ .773±.006 | 4.051±.610/ 2.657±.068 | |
| PPG+ACC | 20% | .601±.006/ .629±.051 | .266±.001/ .279±.011 | .711±.002/ .741±.006 | 3.580±.058/ 2.662±.060 |
| 50% | .600±.009/ .634±.048 | .266±.005/ .251±.002 | .698±.006/ .703±.017 | 3.707±.146/ 2.859±.129 | |
| PPG+TEMP | 20% | .611±.011/ .625±.050 | .273±.002/ .277±.010 | .716±.004/ .753±.005 | 3.673±.154/ 2.613±.066 |
| 50% | .623±.019/ .632±.054 | .255±.002/ .260±.008 | .709±.008/ .742±.007 | 3.943±.427/ 2.641±.098 | |
| EDA+ACC | 20% | .582±.007/ .612±.044 | .249±.002/ .307±.009 | .718±.003/ .748±.008 | 3.566±.117/ 2.614±.051 |
| 50% | .536±.005/ .582±.041 | .242±.002/ .292±.013 | .712±.004/ .718±.013 | 3.595±.274/ 2.655±.059 | |
| EDA+TEMP | 20% | .588±.009/ .613±.050 | .266±.005/ .304±.010 | .720±.003/ .759±.006 | 3.692±.142/ 2.562±.068 |
| 50% | .540±.030/ .590±.043 | .238±.002/ .305±.013 | .715±.004/ .753±.007 | 3.969±.303/ 2.547±.088 | |
| ACC+TEMP | 20% | .609±.011/ .625±.051 | .275±.003/ .297±.004 | .714±.004/ .737±.003 | 3.569±.136/ 2.609±.062 |
| 50% | .614±.012/ .629±.051 | .277±.006/ .283±.005 | .704±.007/ .688±.011 | 3.610±.138/ 2.621±.077 | |
| PPG+EDA+ACC | 20% | .582±.011/ .623±.049 | .254±.003/ .292±.008 | .714±.002/ .751±.006 | 3.606±.098/ 2.633±.051 |
| 50% | .534±.009/ .597±.034 | .237±.002/ .274±.007 | .704±.001/ .725±.018 | 3.720±.332/ 2.720±.070 | |
| PPG+EDA+TEMP | 20% | .593±.009/ .612±.050 | .264±.002/ .286±.007 | .718±.002/ .760±.005 | 3.741±.151/ 2.569±.064 |
| 50% | .569±.013/ .597±.050 | .232±.005/ .263±.010 | .716±.004/ .761±.003 | 4.123±.512/ 2.528±.086 | |
| PPG+ACC+TEMP | 20% | .609±.011/ .632±.052 | .274±.005/ .278±.012 | .717±.002/ .740±.004 | 3.575±.103/ 2.640±.068 |
| 50% | .621±.014/ .643±.048 | .268±.003/ .245±.005 | .699±.011/ .703±.007 | 3.733±.154/ 2.792±.117 | |
| EDA+ACC+TEMP | 20% | .593±.006/ .615±.048 | .266±.004/ .305±.008 | .718±.003/ .745±.004 | 3.602±.126/ 2.579±.063 |
| 50% | .562±.008/ .602±.046 | .252±.002/ .302±.009 | .715±.004/ .723±.007 | 3.632±.131/ 2.563±.108 | |
| PPG+EDA+ACC+TEMP | 20% | .597±.008/ .618±.048 | .265±.001/ .292±.007 | .716±.001/ .752±.005 | 3.628±.064/ 2.602±.054 |
| 50% | .592±.008/ .620±.041 | .265±.003/ .282±.007 | .716±.004/ .747±.002 | 3.752±.137/ 2.606±.060 |
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 2/4
- Significance
- 3/4
- Originality
- 4/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
You propose VCR, a two-stage self-supervised framework for incomplete wearable multimodal physiological signals. It designs an orthogonal tokenizer to geometrically decompose sensor embeddings into shared cross-modal semantics and modality-specific residuals, paired with a missingness-aware MoE backbone to adapt computation under arbitrary sensor dropout. The model introduces dual reconstruction losses for full and partial modality missing, and is validated on four real wearable health datasets covering classification and regression tasks. Results show consistent performance gains over supervised and self-supervised baselines on single/multiple modality missing scenarios, with HSIC metrics verifying effective feature disentanglement.
Strengths and weaknesses
Pros: 1. The geometric disentanglement design with clear theoretical grounding is very interesting. Different from prior multimodal methods that rely on soft orthogonal loss penalties, you try to construct strict orthogonal subspaces via QR decomposition and geometric projection operators to separate shared and modality-unique features. Mathematically, whitening combined with symmetric and idempotent projection guarantees statistical independence between two feature groups, fundamentally solving the information leakage issue of soft constraint disentanglement approaches like FOCAL.
-
VCR designs targeted structural masking loss, while existing wearable self-supervised models mostly only support full training-full test settings or single modality masking. It distinguishes between single missing modality (only reconstruct shared components) and simultaneous multiple missing modalities (abandon reconstruction entirely), avoiding hallucination of unobservable modality-specific physiological features. This is a practical design in real-world scenarios.
-
You test the model performance across diverse downstream tasks including emotion recognition, sleep staging, human activity classification and VO₂ regression, and covers single, double, triple modality missing combinations. You also provide comprehensive ablations for core hyperparameters, MoE position, subspace rank and feature composition, offering abundant empirical evidence to support design choices.
Cons: 1. You fail to formally define the negative sample set used in cross-modal alignment loss Eq. 4, leaving readers unable to confirm the sampling scope of negative wearable signal tokens. More critically, the loss formula contains logically conflicting optimization tendencies: the first term minimizes the similarity between anchor and all samples in set (including positive synchronized tokens ), while the second term maximizes the similarity between and positive samples . Without detailed weight control, the two opposing gradient directions will counteract each other during training, destabilizing cross-modal matching convergence. You must supplement the precise definition of and elaborate how the two competing loss terms are balanced to avoid mutual offsetting in optimization.
-
You suppose that shared components of one missing modality can be reliably inferred from remaining sensors when only one modality drops out, hence enabling shared feature reconstruction. However, you may ignore that if two highly correlated modalities (e.g., EDA and TEMP) are both lost, even the shared physiological semantics related to stress cannot be fully recovered from ACC/PPG alone. The structural masking loss lacks adaptive judgment for correlation strength between modalities, leading to forced reconstruction of unidentifiable shared features and introducing implicit hallucination risks.
-
When the MoE learns incomplete missing-modality inputs, the frozen tokenizer cannot adapt its whitening and projection rules to partial observation distributions, leading to distribution shift between pre-training and downstream missing scenarios. There is no joint fine-tuning ablation to verify whether freezing the tokenizer hurts representation robustness under sensor dropout.
-
You claim whitening with orthogonal projection guarantees and statistical independence of shared s / specific p, but I think it exists a potential error. For non-Gaussian latent distributions, zero covariance cannot equal statistical independence. You only proves linear decorrelation and incorrectly equates it to full feature disentanglement, overstating the theoretical guarantee of the orthogonal tokenizer.
-
You set a high initial rank to reserve large capacity for shared features, but the ablation shows that overly large pushes most physiological information into modality-specific residuals p, degrading the discriminative power of shared embeddings. You do not design an adaptive rank adjustment mechanism to balance shared and specific capacity dynamically. I think relying only on fixed hyperparameters may create a sensitive hyperparameter bottleneck that harms generalization across different wearable datasets.
Questions
See Pros and Cons.
Limitations
Limitations have been included in the paper.
Final justification
As stated in my final comment, I would retain my positive score, and I will be happy to see this work accepted on the condition that the authors polish the main figure (Fig. 2) and revise the serious theoretical issues.
Formatting concerns
No such concern.
8 comments
Author Rebuttal to Reviewer Myf8 [Part 1/2]
We thank Reviewer Myf8 for the detailed technical comments. In response, we: (1) address the concern regarding conflicting optimization, (2) clarify the implicit hallucination issue, (3) address the concern about distribution shift, (4) revise our claims regarding independence, and (5) clarify the concern about the rank.
Detailed responses are provided below. Please see our response to the AC for the experimental results.
1. Negative Samples and Competing Alignment Gradients
We thank the reviewer for identifying this omission. We will explicitly define the negative set for an anchor as:
= { }
where denotes the current mini-batch. Thus, synchronized shared embeddings from the other modalities of sample constitute , while shared embeddings from the other samples constitute , and:
We would also like to clarify the optimization behavior. The two terms in Eq. 4 are not independently weighted competing objectives. They represent the expanded logarithmic form of a single, unified multi-positive InfoNCE loss:
Let be the scaled similarity logit, such that . Let represent the sum of all sample similarities in the denominator, and represent the sum of positive similarities in the numerator. For a positive sample logit , the gradient is (since ). For a negative sample logit , the gradient is .
Gradient descent therefore consistently increases positive similarity and decreases negative similarity, without requiring additional weight balancing. We will rewrite Eq. 4 in this ratio form and add this clarification to prevent ambiguity.
2. Identifiability of Shared Features Under Severe Missingness
Thank you for this detailed comment. We agree that when two correlated modalities are simultaneously missing, their shared semantics may not be identifiable from the remaining sensors.
VCR explicitly handles this case. As stated in Sec. 2.4 and Eq. 9, shared-feature reconstruction is performed only when exactly one modality is missing. When two or three modalities are missing, we reconstruct neither their shared nor modality-specific components, thereby avoiding the implicit hallucination risk described by the reviewer.
We will clarify this point in the revision.
3. Frozen Tokenizer and Distribution Shift
Thank you for raising this important point. We would like to clarify that the tokenizer processes each modality independently. Its whitening and projection operations are applied separately, ensuring that an observed signal’s token remains identical regardless of whether other modalities are missing.
Since missing-modality tokens are discarded before entering the backbone, freezing the tokenizer does not create the proposed partial-observation distribution shift. The changing set of tokens occurs at the backbone input and is intentional.
Moreover, the MoE backbone has been exposed to both full-modality inputs and various modality-missing scenarios during training. Therefore, encountering missing modalities in downstream tasks does not constitute an out-of-distribution problem for the backbone.
During downstream fine-tuning, the pretrained model is updated end to end; during linear probing, it remains frozen by design. We agree that a freeze-versus-joint-pretraining ablation would be useful and will state this as a limitation.
4. Decorrelation Versus Statistical Independence
Thank you for highlighting this important theoretical distinction. We fully agree that zero covariance does not imply statistical independence for general non-Gaussian distributions.
Our derivation explicitly relies on the multivariate-Gaussian assumption. Specifically, our construction unconditionally guarantees that s and p lie in complementary orthogonal subspaces, which enables full independence only under this standard assumption.
For practical representations that may not perfectly satisfy this assumption, our HSIC evaluation in Table 3 provides empirical evidence that the dependence between s and p is substantially reduced.
We also agree that our current wording appeared to be too strong. We will revise:
“This guarantees that s contains no information about p”
to:
“Under the stated Gaussian assumption, this supports approximate statistical independence between s and p.”
Author Rebuttal to Reviewer Myf8 [Part 2/2]
5. Adaptive Rank Selection and Hyperparameter Sensitivity
Thank you for raising this technical concern. We would like to clarify that the rank in VCR is learnable and adaptive.
As described in Appendix G, we associate each orthogonal basis with a learnable hard gate that determines whether the basis is included in constructing the projection operator, thereby adapting the effective rank of the shared embedding during training.
The reported initial rank only initializes these gates and does not determine the final rank. We acknowledge that this mechanism was not sufficiently explained in the main text, and we will revise the method section to make it explicit.
We agree that an excessively large λ_recon can cause an imbalance between reconstruction and alignment. We set λ_recon / λ_align = 0.1 because the reconstruction loss is approximately one order of magnitude larger than the alignment loss. This ratio balances their weights. Importantly, we use the same ratio across all datasets without dataset-specific tuning.
We further evaluate VCR on WildPPG, which was collected using a different device. During this evaluation, all pretrained model parameters, including the learned rank gates, are frozen, and only a linear probe is trained. The strong results on WildPPG therefore provide additional evidence that the learned decomposition and the shared hyperparameter setting generalize to an unseen dataset and device.
If additional analyses/clarifications are helpful, we are happy to provide them during the discussion.
Dear Reviewer Myf8,
We hope this message finds you well. The discussion period (phase two) has started. Following up on our recent exchange regarding this paper, we would like to kindly check whether you have any further concerns, comments, or feedback.
Your insights are invaluable to us, and we sincerely appreciate your time and consideration. Please feel free to share any additional thoughts or suggestions you may have.
We look forward to hearing from you!
Best regards,
The Authors of Submission7803
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 2/4
- Clarity
- 2/4
- Significance
- 2/4
- Originality
- 2/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper aims to address the challenge of learning a multi-modal representation from incomplete data/ missing simultaneous modality. Authors propose VCR, a self-supervised method to learn a valid representation from incomplete dataset.
Strengths and weaknesses
Weaknesses:
- The paper's motivation relies on several assumptions about real-world modality missingness (e.g., users disabling sensors, modality-specific information being fundamentally non-identifiable, and hallucinations arising from full-modality reconstruction) that are not empirically validated or supported by prior literature. As a result, it is unclear whether the proposed method addresses a practically important problem or is based on the authors' own modeling assumptions.
For example, authors mentioned: "caused by hardware constraints and user-dependent effects (e.g., some wearables omit EDA/TEMP entirely, users disabling PPG to save power, and motion/firmware issues can cause ACC streams to drop out)." I am not aware of commercial evidence showing that this is a common source of missingness in wearable datasets. Empatica E4 does not let participants selectively disable PPG, and Most public datasets do not report this as a missingness mechanism.
Missgness in most cases is completely missing data due to users not wearing the wearable, or an issue with wearable placement.
-
The paper repeatedly claims reconstruction methods hallucinate; however, they never measure hallucination.
-
Evaluation uses synthetic missingness, again because it is not something present in real datasets.
-
The proposed framework consists of several interacting components and optimization objectives, making it difficult to determine which design choices are essential. Simpler alternatives are not sufficiently explored.
-
The method is technically interesting and better motivated than simply reconstructing every absent signal. The selective objective, reconstruct shared information but not unsupported modality-specific detail, is a sensible inductive bias. The breadth of the benchmark, full modality, four single-missing conditions, and all two- and three-missing combinations, is also a genuine strength. The results indicate that VCR is probably doing something useful. Its improvements are particularly convincing for WESAD, WEEE, and some severe missing-sensor conditions. However, overall, the major claims made in the paper remain unproven, such as: orthogonality can guarantee general statistical independence, and shared-specific decomposition corresponds to truly identifiable information.
-
All the datasets used by the paper are small in size, with some only having 15 participants. That makes it hard to assess the method's usability; additionally, all the datasets use the same device, E4. So I remain skeptical of the results.
-
The novelty of the methods seems moderately novel as a complete system, while individual elements of the pipeline remains not novel. The Shared and modality-specific factorization is established in prior work https://neurips.cc/virtual/2023/poster/70617 But the novelty lies in the selective latent reconstruction rule. But ablations seem limited to specifically focus on these aspects.
Overall, although the methods seem interesting, I am not convinced about its theoritcal validity and overall usuability.
Questions
- Can the authors provide stronger evidence that the proposed problem is prevalent in real-world wearable sensing?
- How should the notion of "hallucination" be interpreted in this work?
- How does the proposed method perform under more realistic missingness scenarios?
- Can the authors clarify which components are essential for the observed performance gains?
Limitations
The authors acknowledge the limitation that the evaluation is restricted to datasets collected using a single wearable device and discuss the need for future validation across devices. This is appreciated. However, I believe several important limitations are missing. First, the paper does not discuss that the proposed missingness scenarios are synthetically simulated by removing complete modalities, which may not accurately reflect real-world wearable deployments where missingness is often partial, or caused by signal corruption rather than complete sensor absence.
Final justification
Rebuttal satified my concerns.
Formatting concerns
N/A
6 comments
Author Rebuttal to Reviewer 2HPX [Part 1/2]
We thank Reviewer 2HPX for the detailed comments on real-world missingness, hallucination measurement, realistic missingness scenarios, component necessity, theoretical validity, dataset scale, and novelty. In response, we (1) strengthen the practical motivation for modality absence, (2) revise “hallucination” to “hallucination-like completion,” (3) add within-window temporal-dropout evaluation, (4) clarify the contribution of each component through ablations, and (5) narrow our theoretical and identifiability claims.
Detailed responses are provided below. Please see our response to the AC for the experimental results.
1. Evidence for Real-World Modality Missingness
Thank you for raising this concern. We agree that non-wear and improper placement are common causes of missing data. Our target setting is the complete absence of a modality within an analysis window, which is also practically relevant to cross-device deployment.
Commercial devices expose substantially different sensor suites: Oura Ring 4 [A] lacks ECG, EDA, and an altimeter; Fitbit Sense 2 [B] includes all three; and Apple Watch Series 9 [C] lacks EDA. Thus, a model pretrained on one sensor suite may need to generalize to devices providing only a subset of its modalities.
Recent wearable studies, including MAESTRO [49], LSM-2 [15], and CIMSleepNet [D], also explicitly consider complete modality loss caused by hardware malfunction, battery conservation, or sensor detachment. Such missingness is also prevalent in commercial wearables: over 3 months of daily tracking, [H] reports valid heart rate data on only 31.2%, 80.1%, and 49.3% of days for Samsung Galaxy Watch, Fitbit, and Apple Watch, respectively. We will clarify that these are representative practical scenarios and add the above references.
We would also like to clarify that the distinction between modality-shared and modality-specific information follows prior work [20], which factorizes each modality into a shared component that captures cross-modal consistency and a private component that captures modality-exclusive information. Under this formulation, when an entire modality is absent, its private component is not reliably recoverable from the remaining modalities.
2. Interpretation and Measurement of Hallucination
Thank you for highlighting this issue. We agree that the original manuscript did not sufficiently support the use of “hallucination”. Prior work [E,F] commonly characterizes hallucination as generation that appears plausible or semantically coherent but is incorrect or unfaithful to the conditioning input. Following this interpretation, we add a more comprehensive case study. LSM-2 achieves substantially lower reconstruction MAE than VCR (0.426 vs. 0.509), indicating higher signal-level fidelity to the ground-truth waveform. However, its reconstructed signals induce a larger representation shift: the cosine similarity between the original and reconstructed representations is 0.732 for LSM-2, compared with 0.813 for VCR. Moreover, the representation shift is significantly positively correlated with the drop in the ground-truth class probability (Pearson (r=0.561), (p<0.001)), indicating that this is harmful and incorrect shift. Together, these results show that a reconstruction can be close to the true signal at the waveform level while introducing task-relevant semantic errors. This provides converging evidence consistent with hallucination-like completion.
However, unlike images or natural language, wearable signals cannot be intuitively understood by human perception, and there is currently no established metric that directly identifies hallucination in reconstructed wearable signals. We will therefore revise “hallucination” throughout the paper to “hallucination-like completion”.
3. Realistic Missingness Scenarios
Thank you for raising this important concern. We agree that partial or intermittent modality missingness is also common in real-world wearable deployments, and that signal corruption constitutes another practically relevant form of incompleteness.
To address this concern, we have added contiguous temporal-dropout evaluation over all four downstream datasets, all nonempty modality subsets, and 20% and 50% dropout ratio.
We compare against three missingness-aware baselines: supervised FlexMoE, supervised MAESTRO, and SSL-based LSM-2. Across 120 dataset–subset–ratio settings, VCR-FT achieves the best mean performance in 116 cases and ties in 2, while VCR-LP outperforms LSM-2 in 115 cases and ties in 1.
These results demonstrate that VCR remains robust under partial or intermittent modality missingness. We will include the complete results in the revision.
Author Rebuttal to Reviewer 2HPX [Part 2/2]
4. Essential Components and Simpler Alternatives
Thank you for raising this concern. We would like to clarify that we have systematically examined the necessity of the major architectural components and optimization choices through the ablation studies in Sec. 3.3.
On the architectural side, we evaluate:
- replacing our orthogonal tokenizer with a FOCAL-type tokenizer using a soft disentanglement constraint;
- removing the missing-aware MoE backbone;
- replacing the learnable partition embeddings with fixed sinusoidal encodings.
On the objective side, for structurally dropped modalities, we compare our strategy of reconstructing only the shared component s against two simpler alternatives:
- reconstructing neither
snorp; - reconstructing both
sandp.
As shown in Fig. 5, nearly every ablated variant leads to a clear and consistent performance degradation across the three downstream tasks and four missing-modality settings, with only one exception among 60 evaluated metrics. These results demonstrate that each design choice contributes meaningfully to the final performance.
5. Theoretical Validity and Identifiability
We agree with the reviewer’s central point. VCR does not prove general statistical independence or unique semantic identifiability. The projection guarantees complementary geometric subspaces. Zero cross-covariance additionally requires the whitening condition, and independence further requires jointly Gaussian latent variables. These conditions are not guaranteed for practical representations. We will remove unconditional independence claims.
We would also like to clarify that our use of “non-identifiable” refers to the conditional unrecoverability of modality-specific information from the remaining observed modalities, rather than claiming that the learned shared–specific decomposition is uniquely identifiable in the latent-variable sense. We operationally encourage s to capture cross-modal consistency through cross-modal alignment and p to retain modality-specific residual information through intra-modal reconstruction. We will revise the manuscript to make this scope explicit and replace wording that may imply strict semantic identifiability.
6. Dataset Scale and Single-Device Evaluation
We appreciate the reviewer’s concern regarding dataset size. Participant numbers within this range are common in wearable sensing research, largely because collecting synchronized physiological signals is costly and labor-intensive; for example, WildPPG [G] includes 16 participants. We will strengthen the limitation regarding population-scale and multi-device evaluation.
7. Novelty and Targeted Ablations
We would like to clarify that while FOCAL also factorizes representations into shared and modality-specific components, it enforces their separation through a soft orthogonality loss. In contrast, VCR constructs strictly orthogonal subspaces via whitening and geometric projection, which minimizes information leakage between the shared and modality-specific subspaces.
This separation enables the subsequent selective reconstruction to exclude non-identifiable modality-specific information, thereby reducing hallucination-like completions.
We further clarify that our contribution is not limited to the selective reconstruction rule. To our knowledge, VCR is the first framework to introduce a strict geometric tokenizer as well as an explicit inductive bias that restricts reconstruction to inferable information and mitigates hallucination-like completions. Its integration with selective reconstruction and missingness-aware modeling constitutes a novel overall architecture, as also recognized by the AC.
References
[A] https://support.ouraring.com/hc/en-us/articles/33045011508115-Oura-Ring-4
[B] https://store.google.com/us/product/fitbit_sense_2_specs
[C] https://support.apple.com/en-us/111833
[D] Robust Sleep Staging over Incomplete Multimodal Physiological Signals via Contrastive Imagination. NeurIPS 2024.
[E] Mitigating Object Hallucinations in Large Vision-Language Models through Visual Contrastive Decoding. CVPR 2024.
[F] Prevent the Language Model from being Overconfident in Neural Machine Translation. ACL 2021.
[G] WildPPG: A Real-World PPG Dataset of Long Continuous Recordings. NeurIPS 2024.
[H]Evaluating Wearable Devices for Remote Monitoring in Psychosis: Pilot Study Nested Within the CONNECT Cohort Study. JMIR 2026.
If additional analyses/clarifications are helpful, we are happy to provide them during the discussion.
Dear Reviewer 2HPX,
We hope this message finds you well. The discussion period (phase two) has started. Following up on our recent exchange regarding this paper, we would like to kindly check whether you have any further concerns, comments, or feedback.
Your insights are invaluable to us, and we sincerely appreciate your time and consideration. Please feel free to share any additional thoughts or suggestions you may have.
We look forward to hearing from you!
Best regards,
The Authors of Submission7803
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 2/4
- Significance
- 2/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
Real-world deployment of wearable sensing applications is challenged by data scarcity and modality missingness. The authors propose VCR, a method that generates representations robust to modality incompleteness by introducing an orthogonal tokenizer and a missingness-aware MoE. The orthogonal tokenizer separates information into modality-specific and modality-shared components, while the missingness-aware MoE adapts to samples with varying modality compositions. Experimental results show that the method improves performance across various wearable health sensing tasks.
Strengths and weaknesses
Strengths:
- Evaluation across various tasks, including emotion detection, activity recognition, sleep staging, and VO2 prediction, as well as different numbers of missing modalities.
- Various experimental analyses demonstrate the performance improvements and behavior of the proposed method, including reconstructed embeddings and expert specialization.
Weaknesses:
- The clarity of the problem definition should be improved. Some statements are conflicting or should be revised for clarity. It is unclear what the final goal is: developing a pre-trained model with missing data, or developing a model with complete data where missingness occurs only during downstream tasks.
- There is a mismatch between the motivation and the experiments. The motivation seems to focus on missing modalities during pretraining, but the evaluation only considers missing modalities during testing phase of the downstream tasks.
- The supervised baselines may not be the best candidates for comparison, since they do not follow the pretrain-then-fine-tune pipeline. They also may not have been given similar training time, which affects the fairness of the evaluation.
- There is a lack of system cost analysis.
Questions
-
Problem setting. What is the eventual goal of the paper? Is it to develop wearable health sensor models that perform well on downstream tasks when modalities are missing during downstream evaluation? Or is it to enable pretraining with missing and limited data? Please clarify this in the abstract and introduction. For example, the statement “While large-scale self-supervised pretraining reduces label dependence, most existing methods assume full modality availability” seems to refer to missing modalities during pretraining, whereas the implementation and experimental details suggest otherwise.
-
Mismatch between motivation and experiments. Throughout the abstract and introduction, the motivation is framed around learning with missing modalities. However, it only becomes clear in the experiments section that missingness is considered only at test time for downstream tasks, while both pretraining and supervised training are conducted in the full-modality setting. Please ensure that the wording in the motivation and introduction is consistent with the experimental evaluation.
-
Supervised baselines. The supervised baselines, such as ResNet, ViT, and FlexMoE, may not receive a fair amount of training time compared with VCR, which involves both pretraining and fine-tuning. I am also not sure whether they are the most relevant baselines, since they do not follow a pretrain-then-fine-tune pipeline. Moreover, among the supervised baselines, only FlexMoE explicitly targets the missing-modality problem. It would be helpful to include additional baselines, such as FuseMoE and MAESTRO, which are mentioned in the appendix, or other baselines that also follow a pretrain-then-fine-tune process.
-
System cost. What are the training costs, including pretraining and downstream task training, and the inference costs, such as GFLOPs, memory usage, and training time? Please also compare these costs with those of the baselines.
Minor comments and questions:
-
In the statement “Current approaches for handling modality missingness often reconstruct entire absent signals,” do you mean pre-trained models or application-specific models? If it is the latter, there are many works that handle missing modalities without imputation or reconstruction, and these should be included as baselines. If it is the former, then pretraining itself should not assume access to complete modalities. Please elaborate.
-
In the introduction, some terms are not explained, such as “imbalanced and conflicting SSL objectives,” “learnable partition embeddings,” and “structural missingness.” Please briefly explain these terms to improve readability.
-
In the experiments, particularly in Tables 1 and 2, the proposed method is not always the best-performing method. Therefore, the paper should be careful when claiming state-of-the-art performance in the introduction.
-
Does Figure 2 represent the pretraining stage? If so, please annotate this in the caption and main text. If not, please explain which part is used for the downstream task.
-
In the method section, please explain what the whitening process does to the embeddings in this context.
-
In the MoE architecture, could you mathematically show how the learnable partition embedding, which identifies the semantic role of each modality, is injected?
-
What is the rationale behind using both random masking and structural masking in the MoE objective?
-
For Figure 4a, please explain the experimental setting. Is it evaluated under missingness, as suggested by the text, or does it show learned expert routing statistics using complete data? If it is evaluated under missingness, adding the missing-modality dimension would help clarify the observed patterns.
Limitations
Yes
Final justification
The authors addressed the important concerns and questions I had, and therefore I decided to raise my score.
Formatting concerns
None
7 comments
Author Rebuttal to Reviewer 4cWz [Part 1/2]
We thank Reviewer 4cWz for pointing out important clarity issues. In response, we (1) clarify the problem setting, (2) add MAESTRO as an additional baseline, (3) provide training and inference cost analysis, (4) define key technical terms more explicitly, and (5) tone down our claims.
Detailed responses are provided below. Please see our response to the AC for the experimental results.
1. Problem Setting and Intended Goal
Thank you for pointing out this ambiguity. We would like to clarify that VCR uses complete synchronized source windows, pretrains the tokenizer with all modalities, and pretrains the backbone MOE with both random patch masking and synthetic removal of 1–3 modalities. Downstream FT/LP uses complete-modality training data, and missing modalities are introduced during evaluation. We will clarify this setting in the abstract and introduction and revise the quoted statement to: "models that perform well on downstream tasks when modalities are missing during downstream evaluation.''
2. Fairness and Relevance of Supervised Baselines
We thank the reviewer for this comment. Comparing self-supervised pretraining followed by fine-tuning against supervised models trained from scratch is a standard evaluation protocol adopted by classical works such as SimCLR [22] and MAE [26].
The purpose is to quantify whether representations learned from additional unlabeled data provide better generalization and transfer than learning solely from limited downstream labels.
Following the reviewer’s suggestion, we added MAESTRO, which is more recent than FuseMoE, as an additional missingness-aware baseline. Across the 56 missing-setting comparisons, including Macro-F1 for the three classification datasets and MAE for WEEE, VCR-FT outperforms MAESTRO in 45. We will include the complete results in the revised manuscript.
3. Training and Inference Cost Analysis
Thank you for pointing out the lack of system cost analysis. We added a comparison of GFLOPs, peak memory usage, and training time for VCR and the baselines.
| Method | GFLOPs | Peak Memory (GiB) | Training Time |
|---|---|---|---|
| VCR | 5.64 | 2.09 | 11.67 GPU-h |
| LSM | 3.07 | 1.55 | 11.06 GPU-h |
| LSM-2 | 2.74 | 2.72 | 50.34 GPU-h |
| SimCLR | 4.08 | 6.50 | 16.73 GPU-h |
| CMC | 1.01 | 1.38 | 8.12 GPU-h |
| MSN | 2.04 | 1.29 | 4.98 GPU-h |
| MFCLR | 0.98 | 2.55 | 11.77 GPU-h |
| ResNet | 15.11 | 5.65 | - |
| ViT | 1.12 | 1.48 | - |
| FlexMoE | 0.86 | 1.68 | - |
| MAESTRO | 5.29 | 4.82 | - |
We will include this system-cost table in the revised manuscript and ensure that the reported pretraining cost is consistent across the main text and appendix.
4. Scope of Reconstruction-Based Methods
We would like to clarify that the statement “Current approaches for handling modality missingness often reconstruct entire absent signals” refers to pre-trained models.
Meanwhile, our goal is to tackle modality missingness at the inference stage rather than during pretraining. Therefore, using modality-complete training data is consistent with our claim.
5. Definitions of Key Technical Terms
Thank you for pointing out that several terms require clearer explanation. We will briefly define them in the introduction.
Structural missingness refers to the complete absence of an entire sensor’s signal for a whole time window.
Learnable partition embeddings are special identification tags that indicate which sensor the token comes from and whether it corresponds to the shared component s or the modality-specific component p.
Imbalanced and conflicting SSL objectives arise because sensors vary substantially in sampling rates and data variance. When multiple learning goals are optimized simultaneously, high-frequency or high-variance signals can dominate the objective and suppress important information from other modalities.
6. Scope of State-of-the-Art Claims
We agree that the proposed method is not always the best-performing method in every setting. We will revise the introduction to tone down the claim. Specifically, we will clarify that VCR achieves highly competitive performance in the majority of evaluated settings, rather than claiming uniform state-of-the-art performance across all tables and metrics.
7. Role of Figure 2
Figure 2 shows both the pretraining and inference stages, as indicated by the existing labels within the diagram.
To prevent future confusion, we will enlarge the “Training” and “Inference” annotations and clarify in the caption and main text which components correspond to pretraining and which are used during downstream inference.
8. Purpose of Whitening
In this context, the whitening process acts as a regularization mechanism that forces the covariance matrix of the encoder’s latent embeddings to approximate the identity matrix: Cov(h) ≈ I.
Author Rebuttal to Reviewer 4cWz [Part 2/2]
9. Mathematical Form of Partition-Embedding Injection
For each token, we inject the learnable partition embedding by element-wise addition to the token representation.
Specifically, for a token representation x_i and its corresponding learnable partition embedding e_i, the input to the MoE backbone is: x_i + e_i. We will include this explicit mathematical form in the revised manuscript.
10. Rationale for Random and Structural Masking
Structural masking is designed to improve robustness against real-world modality missingness, while random masking follows the masked autoencoding principle to encourage contextual representation learning by reconstructing randomly removed patches whose information remains recoverable from surrounding observations.
11. Experimental Setting of Figure 4(a)
Figure 4(a) is evaluated using complete multimodal data and visualizes the learned expert routing statistics under the full-modality setting.
If additional analyses/clarifications are helpful, we are happy to provide them during the discussion.
Dear Reviewer 4cWz,
We hope this message finds you well. The discussion period (phase two) has started. Following up on our recent exchange regarding this paper, we would like to kindly check whether you have any further concerns, comments, or feedback.
Your insights are invaluable to us, and we sincerely appreciate your time and consideration. Please feel free to share any additional thoughts or suggestions you may have.
We look forward to hearing from you!
Best regards, The Authors of Submission7803
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 2/4
- Originality
- 2/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper presents an approach for self-supervised learning with biosignals, which is robust to modality missingness prevalent in wearable computing. The approach, called VCR, employs an orthogonal tokenizer to force disentanglement into modality-shared and modality-specific components. The resulting representations are input to a MoE model that can adapt to varying degrees of missingness. This leads to representations that are robust to entire missing modalities compared to baselines.
The main contribution of this paper lies in their approach. While the disentanglement and use of MoE are not novel, their combination for this application is both novel and useful, from a practical standpoint.
Strengths and weaknesses
The strengths of the paper are:
- Missingness is a prevalent issue in wearable computing applications. As such, it is a great positive that the authors are tackling it. The writing is also clear and paper is mostly easy to understand.
- The use of the orthogonal tokenizer and the MoE are well motivated for this paper. While the individual components are taken from previous papers, their combination is a good match for the task this paper is tackling.
- The fivefold subject cross validation is a definite plus and adds to the reliability of the results.
The weaknesses of this paper are:
- The downstream tasks can be expanded, similar to prior works in the wearables space. For example, here are some examples – WildPPG [1] or ScientISST MOVE [2] but there may be others without the full spectrum of modalities used here.
- The authors claim in a couple of places that masked reconstruction leads to hallucination when modalities are missing. However, this is not proven beyond tSNE analysis, which only measures some drift when a modality is missing. The authors should add further supporting evidence or tone down this claim throughout the paper.
- The information about baselines and their implementation is missing from the paper. Especially for LSM and LSM-2, which do not have public implementations, how did the authors construct the baselines? Did they perform similar amounts of parameter tuning as for VCR? (same with other baselines, did the authors perform similar param tuning?)
- The authors compare against LSM-2, which was designed especially to tackle data missingness, and is also trained on data which has such missingness. On the other hand, VCR is trained on data that is complete, and missingness is only induced artificially. Furthermore, the testing is also done with only artificially induced missingness and not which occurs naturally during data collection.
- Having intermittent data from modalities seems more common than missing entire modalities altogether. For example, LSM-2 shows how some modalities might be missing for some durations of time. But the authors do not evaluate this scenario at all throughout the paper. This can be simulated fairly easily on the downstream datasets, and the authors should add it.
References:
[1] Meier, Manuel, Berken Utku Demirel, and Christian Holz. "Wildppg: a real-world ppg dataset of long continuous recordings." Advances in Neural Information Processing Systems 37 (2024): 2246-2266.
[2] https://physionet.org/content/scientisst-move-biosignals/1.0.1/
Questions
The following questions need more clarity, but the authors should also look at the other points above:
- How are the different sensors with varying sampling rates encoded by the approach? This is not clear from the paper.
- Some details about the approach need more clarity:
- To train the MoE router, the authors mention that they inject learnable embeddings to identify the semantic role. It is not clear what this means or how many such roles exist. It is only which modality (i.e., one per type) and one for
svsp? Furthermore, how is this different from assigning a mask token as in the case of MAE? - The authors also mention that the backbone is tasked with mining deep contextual semantics from the tokenizer outputs. Could the authors clarify what they mean?
- To train the MoE router, the authors mention that they inject learnable embeddings to identify the semantic role. It is not clear what this means or how many such roles exist. It is only which modality (i.e., one per type) and one for
- How does the performance of VCR compare against unimodal approaches trained for those specific modalities? Is there any advantage to pre-training with multiple modalities (even if the pre-training data scale is lower)?
- The authors should also add some descriptions about the modalities within the downstream datasets.
- The balanced accuracy does not add much info that the macro F1 or cohen’s kappa do not. It can be removed to make the table more readable.
Limitations
The limitations are:
- The paper does not tackle intermittent missingness where can be there can be some sensors that malfunction for short durations of time. Instead, the authors only focus on situations where a sensor outputs no data throughout. Otherwise, they should point towards literature that mentions that sensors missing entirely is the overwhelming possibility.
- The downstream eval datasets should be expanded, along with comparisons to leading univariate models as well.
- As the authors acknowledge, data from only one device (the E4) is used for pre-training. As such, no other dataset with a diff combination of sensors has been used for pre-training.
Final justification
The proposed approach outperforms existing baselines, including LSM-2, when modalities are missing entirely.
The authors have addressed the points raised in the review, including a number of clarifications. Furthermore they have also evaluated on two additional datasets, which showcases perf in different settings.
Formatting concerns
N/A
9 comments
Author Rebuttal to Reviewer w1kp [Part 1/2]
We thank Reviewer w1kp for the detailed suggestions. In response, we (1) add cross-device evaluation on WildPPG, (2) provide more quantitative evidence and revise “hallucination” to “hallucination-like completion,” (3) clarify baseline implementation and tuning fairness, (4) add intermittent-dropout experiments, and (5) clarify methodological details
Detailed responses are provided below. Please see our response to the AC for the experimental results.
1. Breadth of Downstream Evaluation
We agree that evaluating downstream tasks on datasets from different sensors could further support our motivation for cross-device generalization. We selected WildPPG for additional evaluation since ScientISST MOVE uses the same Empatica E4 wristband as our pretraining datasets. Following the original study, we evaluated VCR with the linear probe protocol and obtained ground truth using their established method.
According to the result, with only PPG available, frozen VCR with a linear probe achieves MAE/RMSE/ of 13.92/17.52/14.32, compared with 31.79/34.60/8.19 for our LSM-2 implementation. As a contextual comparison, VCR outperforms 5/7 WildPPG-pretrained SSL methods reported in the original paper and approaches the best MAE result of 10.55.
2. Evidence for Reconstruction-Induced Hallucination
Thank you for this important comment. We would like to clarify that the original case study was not based solely on the qualitative t-SNE visualization. It also included two quantitative analyses.
Specifically, LSM-2 exhibited lower cosine similarity between the original and reconstructed representations than VCR (0.732 vs. 0.813), indicating a larger representation shift. Moreover, this shift was significantly positively correlated with the drop in the ground-truth class probability (Pearson r = 0.561, p < 0.001). These results show that reconstructing the entire missing modality is associated with task-relevant semantic shifts that are harmful to prediction.
Nevertheless, we agree with the reviewer’s point that such representation-level evidence does not directly identify hallucination.
Prior work [A,B] commonly characterizes hallucination as generation that appears plausible or semantically coherent but is incorrect or unfaithful to the conditioning input. Following this interpretation, we have further expanded the case study by reporting reconstruction MAE. LSM-2 achieves a lower reconstruction MAE than VCR (0.426 vs. 0.509), indicating greater signal-level proximity to the ground-truth waveform. However, it produces a larger representation shift with the significant correlation between itself and the performance drop.
These results show that a reconstruction can be relatively close to the true signal at the waveform level while still introducing harmful task-relevant semantic errors. The combined evidence is therefore consistent with hallucination-like completion.
However, unlike images or natural language, wearable signals cannot be intuitively understood by human perception, and there is currently no established metric that directly identifies hallucination in reconstructed wearable signals. We therefore agree to revise “hallucination” throughout the paper to “hallucination-like completion.”
3. Baseline Implementation and Parameter Tuning
Thank you for raising this concern. Since official implementations of LSM and LSM-2 are unavailable, we reimplemented them following the architectures and training procedures reported in the original papers.
All baselines were trained from scratch using the same data, subject-independent splits, input windows, and evaluation protocol as VCR. For capacity matching, we preserved the method-defining topology and objectives while scaling model width to approximately 50M parameters. Specifically, for LSM-2, we retained its 12-layer encoder, 4-layer decoder structure. For LSM, we retained its 12-layer encoder and 8-layer decoder structure. We also strictly followed LSM-2’s artificial masking protocol: each sample uses, with equal probability, either 80% random masking, 50% temporal-slice masking, or 50% signal-slice masking.
All methods received the same hyperparameter-tuning effort, defined by the same number of search trials, subject-wise validation protocol, and comparable computational budget, without access to test subjects. We tuned hyperparameters, including learning rate, weight decay, dropout, warm-up ratio, and downstream learning rate using method-specific search spaces centered on the values recommended by the original papers. VCR was not allocated a larger tuning budget than any baseline.
Author Rebuttal to Reviewer w1kp [Part 2/2]
4. LSM-2 Comparison and Artificial Missingness
Thank you for raising this point. We would like to clarify that, since neither the original LSM-2 pretraining data nor its pretrained model parameters are publicly available, for a fair comparison, we reimplemented LSM-2 and trained it on exactly the same complete pretraining data as VCR, while following its original artificial masking strategy. This controlled setting ensures that both methods use the same pretraining data and isolates their methodological differences. We will clarify this explicitly in the revised paper.
We agree that entire modality missingness does not fully reproduce naturally occurring missingness, whose locations, durations, and dependencies on sensors and user behavior may be structured. To address the reviewer’s concrete concern about intermittent dropout, we added the following intermittent missingness evaluation.
5. Intermittent Missingness Evaluation
Thank you for highlighting this important question. We add contiguous within-window dropout evaluation. For each nonempty modality subset, we mask a contiguous 2-second or 5-second segment and evaluate without training on contiguous-dropout patterns. We compare VCR against three missingness-aware baselines: the supervised FlexMoE and MAESTRO and the SSL-based LSM-2. Across 120 settings, VCR-FT is best in 116 and ties in 2, while VCR-LP outperforms LSM-2 in 115 and ties in 1. These results extend the evaluation beyond complete whole-window modality absence. These results demonstrate that VCR remains robust under short, intermittent missingness.
6. Encoding Sensors with Different Sampling Rates
Each 10-second input is divided into ten 1-second patches for every modality. A patch contains 64d PPG input, 3$\times$32d ACC input, or 4d EDA/TEMP input. A modality-specific 1D ResNet maps each raw patch to one d=256 token. Thus, all modalities have the same token-sequence length and embedding dimension, despite having different raw sampling rates and channel counts.
7. Learnable Embeddings
There are exactly 8 distinct learnable partition embeddings in our framework, corresponding to the combinations of our 4 modalities and their 2 semantic components, namely s and p.
Furthermore, our partition embeddings are fundamentally different from the mask tokens in MAE. While MAE uses mask tokens as shared placeholders to fill in missing patches for reconstruction, our embeddings are injected strictly into the observed tokens to explicitly inform the MoE router of their semantic identities and origins.
8. Meaning of Deep Contextual Semantics
By “contextual semantics,” we mean the global representation obtained by integrating within-modality temporal dependencies and cross-modal interactions across the observed tokens. We will replace the vague phrase “mining deep contextual semantics” with this explicit description.
9. Comparison with Unimodal Approaches
We agree that the current experiments do not establish superiority over separately pretrained modality-specific specialists. The added PPG-only WildPPG experiment provides one relevant comparison but does not cover all modalities. Our primary advantage is different: VCR provides one reusable pretrained model that can operate over arbitrary subsets of the known modalities, rather than requiring a separate model (or modal-fusion layers) for every modality or subset. We will narrow the corresponding claim and identify controlled modality-specific pretraining comparisons as future work.
10. Description of Downstream Modalities
All four downstream datasets contain the E4 modalities used by VCR: PPG at 64 Hz, three-axis ACC at 32 Hz, and EDA and TEMP at 4 Hz. WESAD evaluates three-class emotion recognition, DaLiA evaluates eight-class activity recognition, AAUWSS evaluates five-stage sleep classification, and WEEE evaluates regression.
11. Choice of Evaluation Metrics
We agree that BAcc shows trends largely consistent with Macro-F1 and Cohen’s kappa in our experiments and will move BAcc to the appendix.
12. Cross-Device Pretraining Generalization
We agree that pretraining remains limited to one device family. The added WildPPG experiment evaluates downstream transfer of an E4-pretrained PPG representation to a non-E4 device, but it does not establish heterogeneous-device pretraining or multimodal cross-device generalization. We clarify that VCR addresses modality missingness at the inference stage, rather than missingness during pre-training.
References
[A] Mitigating Object Hallucinations in Large Vision-Language Models through Visual Contrastive Decoding. CVPR 2024.
[B] Prevent the Language Model from being Overconfident in Neural Machine Translation. ACL 2021.
If additional analyses/clarifications are helpful, we are happy to provide them during the discussion.
Dear Reviewer w1kp,
We hope this message finds you well. The discussion period (phase two) has started. Following up on our recent exchange regarding this paper, we would like to kindly check whether you have any further concerns, comments, or feedback.
Your insights are invaluable to us, and we sincerely appreciate your time and consideration. Please feel free to share any additional thoughts or suggestions you may have.
We look forward to hearing from you!
Best regards,
The Authors of Submission7803
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Experimental Results [Part 1/4]
Table A. Cross-device performance comparison
Better results are highlighted in bold.