potentialpaper

Touch-R1: Reinforcing Touch Reasoning in MLLMs

Yingxin Lai, Yafei Zhou, Fucai Zhu, Siyu Zhu, Weihao Yuan

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

TL;DR. Touch,MLLM

Abstract. While rule-based reinforcement learning has recently catalyzed explicit reasoning in multimodal models, tactile reasoning remains largely underexplored. Existing tactile-language models primarily rely on supervised or contrastive objectives, which limits their capacity to ground predictions in physical evidence or rectify misleading visual priors. Tactile reasoning introduces two modality-specific challenges: the ordinal nature of physical attributes (e.g., hardness, roughness) and the cross-sensor distribution shifts inherent in optical tactile hardware. In this work, we introduce TouchReason-1M, a large-scale multimodal dataset comprising over 1M synchronized tactile pairs across four distinct sensors, and TouchReason-Bench, a rigorous framework for evaluating tactile perception and visual-tactile conflict resolution. Building upon these, we propose Touch-R1, a tactile reasoning MLLM based on Qwen2.5-VL-7B. Touch-R1 is trained via a tactile-grounded GRPO objective that combines ordinal-aware accuracy, cross-sensor physical consistency, structured-format control, and an input-side tactile grounding objective. Specifically, the input-side tactile grounding objective encourages the policy to respond to perturbations of tactile inputs. On TouchReason-Bench, Touch-R1-7B outperforms Octopi-13B and GPT-4o by 18.4 and 24.7 points, respectively, in the aggregate score. Its structured reasoning traces reveal emergent behaviors of probing, comparison, and revision, demonstrating that R1-style reasoning can be effectively grounded in physical contact. Our code and data will be made public on the project page: https://laiyingxin2.github.io/Touch-R1/.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
29 Apr 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)forumreviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:48 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

a) Summary: This paper focuses on tactile-language models, presenting multiple useful artifacts for grounding LLMs in physical tactile sensor information, including TouchReason-Bench benchmark, a large tactile reasoning dataset built from several heterogeneous optical sensors, and a model finetuned from this data. The methodology is appropriately evaluated and ablated.

b) Strengths:

  • This paper presents incredibly useful artefacts to the community; I am in fact surprised not many people have done this before.
  • Multiple reviewers praise the extensive comparisons and ablations.
  • Well executed paper overall, with strong motivation and strong model, dataset, and benchmark contributions

c) Weaknesses:

  • Multiple reviewers bring up (and I agree with them) that a single run and no statistical tests is a bit concerning, especially given the high variance. It would be helpful if for the rebuttal the authors ran at least 3 seeds to get more confidence in the results.
  • I agree with Reviewer zBKY that if the paper doesn't compare against SOTA baselines finetuned on the new dataset it is unclear how much of the performance increase is due to the dataset or due to the model.

d) Overall the reviews are trending towards accept. The decision would be more solid if the rebuttal addressed comments on statistical significance (e.g., run at least 3 seeds to handle the high variance), on the possibility of finetuning baselines with the new dataset (or an explanation for why that's difficult/ill-posed)

Final justification

The authors have addressed both my concerns and I believe both new results will strengthen the manuscript. I continue to be in favor of an accept.

Area Chair jhZd · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

a) Summary: This paper focuses on tactile-language models, presenting multiple useful artifacts for grounding LLMs in physical tactile sensor information, including TouchReason-Bench benchmark, a large tactile reasoning dataset built from several heterogeneous optical sensors, and a model finetuned from this data. The methodology is appropriately evaluated and ablated.

b) Strengths:

  • This paper presents incredibly useful artefacts to the community; I am in fact surprised not many people have done this before.
  • Multiple reviewers praise the extensive comparisons and ablations.
  • Well executed paper overall, with strong motivation and strong model, dataset, and benchmark contributions

c) Weaknesses:

  • Multiple reviewers bring up (and I agree with them) that a single run and no statistical tests is a bit concerning, especially given the high variance. It would be helpful if for the rebuttal the authors ran at least 3 seeds to get more confidence in the results.
  • I agree with Reviewer zBKY that if the paper doesn't compare against SOTA baselines finetuned on the new dataset it is unclear how much of the performance increase is due to the dataset or due to the model.

d) Overall the reviews are trending towards accept. The decision would be more solid if the rebuttal addressed comments on statistical significance (e.g., run at least 3 seeds to handle the high variance), on the possibility of finetuning baselines with the new dataset (or an explanation for why that's difficult/ill-posed)

Final justification

The authors have addressed both my concerns and I believe both new results will strengthen the manuscript. I continue to be in favor of an accept.

1 comment
Authors · CommentOpenReview ↗

Dear Area Chair jhZd,

Thank you very much for your encouraging assessment and for clearly identifying the two issues that would make the evidence more conclusive. We have addressed both points in our rebuttal.

1. Statistical reliability. We reran the cold-start SFT baseline, Vanilla GRPO, and every cumulative Touch-R1 configuration with five independent seeds. We now report the mean and standard deviation across seeds, together with paired 95% confidence intervals from 10,000 cluster-bootstrap resamples over 200 held-out object clusters, keeping questions from the same object together. Vanilla GRPO has a 1.4-point standard deviation on Avg, confirming the need for repeated runs. The Ordinal and Consistency additions yield +4.5 [3.1, 5.8] and +3.7 [2.4, 5.1] Avg points, respectively; the smaller Format and Grounding additions yield +0.9 [0.1, 1.7] and +0.9 [0.2, 1.6]. We will present these as cumulative, order-dependent marginal gains and state the variance limitation in the main text.

2. Controlled baseline adaptation. We fine-tuned AnyTouch+Qwen and SToLa-13B on the same TouchReason-1M SFT split. SToLa improves from 47.50 Avg with its released checkpoint to 53.21 after TouchReason-1M SFT and 54.52 after Vanilla GRPO. Touch-R1 obtains 60.12, outperforming SToLa+GRPO, the strongest non-Touch-R1 baseline in the table, by 5.60 points. Among baselines initialized from the identical Qwen TR-SFT checkpoint, Qwen+GSPO performs best at 53.84; Touch-R1 exceeds it by 6.28 points. We will revise Table 2 to separate released-checkpoint, same-data SFT, and same-checkpoint RL comparisons, and describe the original 12.6-point gap only as a system-level comparison.

Thank you again for highlighting these concerns. We hope the added controlled baselines and repeated-run analysis provide the requested confidence in the results.

Reviewer Uk3wOpenReview ↗
Rating
4/6
Confidence
3/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
2/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The paper presents a large-scale tactile reasoning dataset (TouchReason-1M) and a multimodal framework (Touch-R1) that integrates vision, force, and optical tactile signals into a multimodal language model. The model is first trained via supervised fine-tuning and then further optimized using reinforcement learning with a tactile-use reward, aiming to encourage grounding in tactile information rather than relying on visual priors. Overall, the work is comprehensive and well-executed, and it demonstrates that incorporating tactile-aware reasoning leads to significant improvements in QA performance metrics.

Strengths and weaknesses

Strengths

  1. Large-scale multimodal tactile dataset. TouchReason-1M contains over 1,000 objects, 14.7K tactile sequences, and 1.3M synchronized tactile observations. Its scale, together with synchronized tactile, force, and visual signals, exceeds many prior tactile datasets that primarily focus on classification, captioning, or representation learning.

  2. Physically grounded interaction protocol. The data collection protocol includes normal pressing from 0–20 N and exploratory motions at multiple force levels, specifically 5 N and 15 N. These interactions capture deformation, compliance, shear response, contact geometry, and surface texture, which are directly relevant to tactile reasoning.

  3. Ordinal physical-property annotations. The use of ordered labels for hardness, roughness, and protrusion better reflects the continuous and ordinal nature of tactile perception. This provides more meaningful supervision than treating these physical properties as purely categorical labels.

  4. Addresses an important question in embodied AI. A central challenge for multimodal embodied models is determining whether the model is actually using a given modality rather than relying on shortcuts from vision, language, or object-category priors. The paper explicitly targets this issue through tactile-use rewards and counterfactual tactile perturbations, making the problem formulation timely and important.

Weaknesses

  1. Limited evaluation beyond optical tactile sensors. While the inclusion of four optical tactile sensors is a notable strength, the benchmark does not evaluate generalization to other tactile sensing technologies, such as capacitive taxel arrays, force-sensitive resistor arrays, or event-based tactile sensors. As a result, it remains unclear whether the learned representations capture broadly sensor-invariant physical properties or are primarily adapted to optical tactile sensing.

  2. Potential variability from handheld data collection. The handheld acquisition protocol enables large-scale collection across many objects and sensors, but it may introduce uncontrolled variation in contact pose, velocity, pressure profile, and exploration behavior. Compared with robot-controlled exploration, this makes it more difficult to assess repeatability and to isolate the effects of individual interaction parameters.

  3. Reliance on synthetic QA generation. A substantial portion of the QA annotations and rationales are generated using Gemini 2.5 Pro. As a result, the dataset may inherit linguistic artifacts, template biases, or reasoning shortcuts commonly observed in synthetic instruction data. Although the authors report filtering and partial human verification, additional analysis of annotation quality, human-authored comparisons, or shortcut tests would strengthen confidence in the generated QA data.

  4. The benchmark primarily evaluates reasoning about object-level attributes such as hardness, roughness, protrusion, and material. While these are important tactile perception tasks, it remains unclear how strongly performance on TouchReason-Bench correlates with more complex tactile-feedback applications, such as grasp stability prediction, slip detection, insertion, manipulation under contact, or active tactile exploration.

Questions

Here are some of my suggestions:

  1. The paper assumes that performance degradation under tactile corruption indicates true tactile utilization. However, the proposed RL objective may instead encourage the model to become sensitive to the presence of tactile tokens without necessarily performing genuine tactile reasoning. To better disentangle these effects, it would be helpful to report a more systematic modality ablation study, for example: a) Vision only b) Tactile only c) Vision + tactile d) Vision + RL (no tactile) e) Vision + tactile + RL This would help clarify whether RL specifically improves tactile grounding, or whether gains primarily come from increased reliance on multimodal inputs in general.

  2. Since a substantial portion of the QA and reasoning annotations are generated using Gemini 2.5 Pro (with filtering and partial human verification), it would be valuable to evaluate potential bias introduced by synthetic reasoning patterns. A useful additional experiment would be: Train the model on the Gemini-generated QA dataset and evaluate on a smaller, independently collected human-authored tactile QA benchmark. A significant performance gap would suggest that the model may be learning dataset-specific linguistic or reasoning styles rather than generalizable tactile reasoning capabilities.

Limitations

While the paper acknowledges some limitations, several important aspects remain underexplored. In particular, the work does not fully evaluate generalization beyond optical tactile sensing modalities, leaving open whether the learned representations transfer to fundamentally different sensor types. The handheld data collection protocol may also introduce uncontrolled variability in contact dynamics, affecting repeatability and interpretability. In addition, the reliance on LLM-generated QA annotations raises potential concerns about synthetic bias and reasoning artifacts that are not fully analyzed. Finally, the benchmark primarily focuses on object-level attribute reasoning, and its connection to more complex robotic manipulation tasks remains unclear.

Final justification

The dataset scale and physical grounding of the interaction protocol are clear strengths. The rebuttal experiments substantially clarified that the RL objective promotes genuine tactile utilization rather than superficial token sensitivity. The remaining limitations (sensor generalization, complex manipulation correlation, originality) are meaningful but do not outweigh the contributions. I keep my score as weak acceptance for this paper.

Formatting concerns

NA

4 comments
Authors · CommentOpenReview ↗

Reviewer Uk3w

Q1. Evaluation beyond Optical Tactile Sensors

We thank the reviewer for raising this important limitation. The submitted model does not demonstrate raw-signal transfer beyond optical tactile sensors. To evaluate whether its reasoning layer can nevertheless use non-optical tactile evidence, we tested Touch-R1 on PHAC-2, which contains BioTac pressure, vibration, temperature, and electrode-impedance signals.

Because the optical tactile encoder cannot directly process BioTac waveforms, all language-model baselines receive the same fixed, label-independent action-level summary.

Model Macro-F1
Llama-3.1-8B 0.521
Qwen2.5-7B 0.548
MKL, same folds 0.618
Touch-R1 0.654

This result supports reasoning over structured non-optical evidence. It does not establish zero-shot processing of raw BioTac signals or a fully sensor-invariant tactile encoder.

Q2. Handheld Data Collection Repeatability

We thank the reviewer for this constructive comment. To evaluate repeatability, two operators, each using a different DM-Tac X device, repeated the full protocol ten times on five objects.

Metric Operator A / Device A Operator B / Device B Cross-setup
Action completion 98.92% 98.31% —
FzF_z-profile correlation 0.741 0.738 0.858*
Synchronization error (median / P95) — — <10 / <28 ms
Contact-mask IoU 0.629 0.578 0.533
Contact-area ICC(2,1) — — 0.552 [0.228, 0.687]
Depth correlation 0.641 0.432 0.270
Deformation correlation 0.675 0.584 0.412
Shear correlation 0.528 0.581 0.197

The cross-setup FzF_z value compares the two ten-trial mean curves, whereas the within-setup values compare individual trials. The symbol — means that the metric is not applicable to that column, rather than an unreported result.

Action completion exceeds 98% for both setups. The cross-setup FzF_z correlation is 0.858, and the synchronization median and P95 are below 10 ms and 28 ms, respectively, indicating repeatable loading and timing. The cross-setup contact-mask IoU of 0.533 and contact-area ICC of 0.552 indicate moderate contact-region repeatability, while the lower cross-setup depth, deformation, and shear correlations show that fine-grained tactile fields remain more variable.

Q3. Synthetic QA Reliance

We thank the reviewer for this constructive suggestion. The results suggest that the model is not solely reliant on synthetic QA patterns, although a measurable synthetic-style gap remains. To evaluate this directly, we constructed 1,000 paired questions from 500 unseen tactile sequences. Each pair uses the same tactile evidence, task type, and human-verified answer; one question was generated through the Gemini-based pipeline and the other was independently written by human annotators.

Task Gemini-authored Human-authored Gap
Property identification 72.0 69.5 2.5
Ordinal or multi-attribute reasoning 63.0 59.8 3.2
Tactile comparison 61.0 56.5 4.5
Visual-tactile conflict 64.0 59.0 5.0
Macro-average 65.0 61.2 3.8

The human-authored score retains 94.2% of the Gemini-authored score, showing that most performance transfers to independently written questions. The remaining 3.8-point gap indicates residual sensitivity to synthetic question style, particularly for comparison and visual-tactile conflict tasks.

Authors · CommentOpenReview ↗

Q4. More Complex Tactile-Feedback Application

We thank the reviewer for asking whether the learned tactile representation extends to more complex tactile-feedback applications. Following previous work, we evaluated each method as a frozen tactile encoder paired with the same UNet-based Diffusion Policy. We conducted 30 physical trials for each task-sensor condition on grasping, wiping, USB insertion, and chip moving, while keeping the visual encoder, policy architecture, training data, action space, and evaluation protocol fixed; only the tactile encoder differs.

Task and sensor (success rate, %) UniTouch T3 V-JEPA MAE Touch-R1
Grasp, DM-Tac X / GelSight Mini 50.0 / 50.0 60.0 / 53.3 63.3 / 63.3 66.7 / 70.0 76.7 / 76.7
Wipe, DM-Tac X / GelSight Mini 53.3 / 46.7 53.3 / 53.3 70.0 / 70.0 73.3 / 70.0 80.0 / 76.7
USB insertion, DM-Tac X / GelSight Mini 6.7 / 3.3 10.0 / 6.7 13.3 / 10.0 16.7 / 13.3 26.7 / 23.3
Chip moving, GelSight Mini 40.0 60.0 60.0 66.7 76.7
Seven-condition macro-average 35.7 42.4 50.0 53.8 62.4

Touch-R1 improves the seven-condition macro-average success rate from 53.8% to 62.4%, outperforming MAE by 8.6 percentage points. These results support low-rate tactile corrective decisions, including maintaining contact, adjusting force, applying lateral corrections, and terminating actions. Absolute USB-insertion performance remains low, and the experiment does not establish end-to-end control or a formal correlation between TouchReason-Bench performance and robot success.

Q5. Ablation of RL

We thank the reviewer for requesting a systematic modality ablation. The results indicate that the gains cannot be explained solely by the presence of tactile tokens. We compare vision-only, touch-only, multimodal SFT, ordinary GRPO with and without valid tactile observations, and the full Touch-R1 objective.

Setting OMAE↓ Avg↑
Vision only 0.76 32.6
Touch only 0.50 44.9
Vision+touch SFT 0.46 47.8
Vision+ordinary GRPO, no valid touch 0.64 36.1
Vision+touch+ordinary GRPO 0.42 50.1
Vision+touch+Touch-R1 0.24 60.1

The no-valid-touch condition preserves tactile markers, sensor identifiers, image slots, and input length but replaces valid contact observations with pre-contact frames. Under ordinary GRPO, removing valid tactile observations reduces Avg from 50.1 to 36.1. With the same valid multimodal input, Touch-R1 improves Avg from 50.1 to 60.1. These controls support the conclusion that Touch-R1 depends on task-relevant tactile content rather than merely on the presence of tactile tokens.

Authors · CommentOpenReview ↗

Closing Comment

We hope that these additional experiments and clarifications address the Area Chair’s and reviewers’ main concerns. We would greatly appreciate any feedback on whether the concerns have been sufficiently resolved or whether any questions remain. We will be glad to provide further explanations or information during the discussion period.

Authors · CommentOpenReview ↗

We sincerely thank Reviewer Uk3w for the detailed comments on sensor generalization, handheld repeatability, synthetic-QA bias, robotic relevance, and tactile grounding. We hope that the non-optical tactile evaluation, repeatability study, human-authored QA comparison, real-robot experiments, and systematic modality ablation address these concerns.

Reviewer 8dgROpenReview ↗
Rating
4/6
Confidence
3/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The paper tackles tactile-grounded reasoning with multimodal LLMs using high-resolution optical tactile sensors. It offers three things: a large tactile reasoning dataset built from several heterogeneous optical sensors over a thousand-plus objects, with ordinal physical labels and reasoning-style QA; a four-tier benchmark spanning single-property perception, joint/ordinal reasoning, comparison, and visual-tactile conflict; and Touch-R1, a Qwen2.5-VL model trained in three stages (tactile-encoder pretraining, structured cold-start SFT, and a tactile-adapted GRPO stage). The RL reward blends an ordinal-aware accuracy term, a cross-sensor consistency term, and a structured-format term, plus an input-side tactile grounding regularizer. Touch-R1 leads the strongest tactile specialist and frontier MLLMs on the authors' benchmark, and also edges a prior tactile model on an external transfer benchmark.

Strengths and weaknesses

Strengths: The motivation is strong: getting models to treat touch as physical evidence that can override a misleading visual prior, rather than defaulting to object-category shortcuts. The visual-tactile conflict failure mode is real and underexplored, the writing is mostly clear, and the artifacts look genuinely useful.

The paper covers closed and open baselines, tactile specialists, a cumulative ablation, a per-attribute breakdown, a scaling study, a video-prediction comparison, and an external transfer to VTV150K. The external transfer is notable as Touch-R1 wins on a benchmark it did not author (65.5 vs VTV-LLM-7B 60.4), partly controlling for the in-distribution advantage that dominates the main table.

Weaknesses: No significance testing (conceded, Checklist item 7). GRPO is high-variance, yet every number is a single run. The small ablation deltas the argument rests on are exactly where single runs are unreliable.

Main table confounded by in-distribution advantage. Touch-R1 trains and tests on the same sensors, annotation, and QA, while specialists are out of distribution; the 12.6-point margin over SToLa (Table 2) conflates method with matched distribution. The specialist and external-transfer comparisons should lead, not the zero-shot GPT-4o framing.

Questions
  1. Report variance. Provide several seeds or bootstrap intervals for the SFT and each incremental reward row on the main aggregate and ordinal metrics. This is the most important addition.

  2. Report at least one tactile specialist fine-tuned on your training data, so the main table is not in-distribution versus out-of-distribution.

Limitations

The limitations discussion is honest on optical-sensor-only scope, long-tail coverage, deployment cost of a large backbone with long traces, and the absence of long-horizon active touch. A notable item is that the lack of statistical significance is acknowledged in the checklist but not surfaced in the main text, which matters given high GRPO variance and small ablation deltas.

The broader-impacts discussion on privacy, misuse, and hardware concentration is thoughtful.

Formatting concerns

NA

3 comments
Authors · CommentOpenReview ↗

Reviewer 8dgR

Q1. Are the Ablation Results Reliable Given GRPO Variance?

We thank the reviewer for emphasizing the high variance of GRPO. The five-seed results support the main ablation conclusions, while the smaller Format and Grounding gains should be interpreted more cautiously.

We report five-seed means and standard deviations for SFT and every incremental reward row, together with paired 95% confidence intervals from 10,000 object-cluster bootstrap resamples.

Configuration OMAE↓ CSC↑ Avg↑ ΔAvg [95% CI]
Cold-start SFT 0.46 ± 0.04 52.6 ± 0.8 47.8 ± 0.5 —
Vanilla GRPO 0.42 ± 0.09 54.3 ± 1.8 50.1 ± 1.4 +2.3 [0.8, 3.9]
+ Ordinal 0.31 ± 0.03 56.1 ± 1.0 54.6 ± 0.7 +4.5 [3.1, 5.8]
+ Consistency 0.27 ± 0.03 69.2 ± 1.2 58.3 ± 0.9 +3.7 [2.4, 5.1]
+ Format 0.26 ± 0.02 70.4 ± 1.0 59.2 ± 0.8 +0.9 [0.1, 1.7]
Touch-R1 (+ Grounding) 0.24 ± 0.02 71.3 ± 0.9 60.1 ± 0.6 +0.9 [0.2, 1.6]

Vanilla GRPO’s 1.4-point Avg standard deviation confirms that a single run can be misleading. The larger Ordinal and Consistency gains remain clear. Questions from the same object are kept together during bootstrapping, avoiding artificially narrow intervals from treating correlated QA as independent samples. We will move the statistical protocol and this limitation into the main text.

Q2. Does Touch-R1 Mainly Benefit from In-Distribution Training?

We thank the reviewer for identifying this confound. The original 12.6-point gap between released-checkpoint SToLa and Touch-R1 combines the benefit of TouchReason-1M adaptation with the benefit of the proposed training method, and should not be interpreted as an isolated objective-level gain.

We therefore fine-tuned AnyTouch+Qwen and SToLa-13B on the same TouchReason-1M SFT split, applied Vanilla GRPO to the fine-tuned SToLa model, and evaluated Vanilla GRPO, DAPO, and GSPO from the identical Qwen TR-SFT checkpoint used by Touch-R1.

Model Training condition OMAE↓ CSC↑ Avg↑
Qwen2.5-VL TouchReason-1M SFT 0.46 ± 0.04 52.63 ± 0.82 47.84 ± 0.51
AnyTouch+Qwen TouchReason-1M SFT 0.38 ± 0.05 55.42 ± 1.13 51.64 ± 0.72
SToLa-13B TouchReason-1M SFT 0.35 ± 0.04 57.14 ± 1.02 53.21 ± 0.83
Qwen2.5-VL + Vanilla GRPO Identical Qwen TR-SFT checkpoint 0.42 ± 0.09 54.31 ± 1.78 50.13 ± 1.42
Qwen2.5-VL + DAPO Identical Qwen TR-SFT checkpoint 0.38 ± 0.06 58.24 ± 1.27 52.41 ± 1.12
Qwen2.5-VL + GSPO Identical Qwen TR-SFT checkpoint 0.33 ± 0.05 61.82 ± 1.21 53.84 ± 0.98
SToLa-13B + Vanilla GRPO SToLa TR-SFT checkpoint 0.31 ± 0.05 62.53 ± 1.38 54.52 ± 1.18
Touch-R1 Qwen TR-SFT checkpoint 0.24 ± 0.02 71.32 ± 0.88 60.12 ± 0.63

SToLa improves from 47.50 with its released checkpoint to 53.21 after TouchReason-1M SFT, directly confirming a substantial adaptation benefit. Applying Vanilla GRPO further increases it to 54.52. Touch-R1 nevertheless retains a 5.60-point advantage over this stronger tactile-specialist system.

More importantly, Touch-R1 exceeds Qwen+GSPO by 6.28 Avg points when the Qwen TR-SFT initialization, training split, input protocol, and evaluation procedure are fixed. This matched-checkpoint comparison is our primary evidence that the tactile-specific objectives provide gains beyond data adaptation and generic RL. We will lead with these controlled comparisons and present the original 12.6-point difference only as a system-level result.

Q3. Long-Horizon Tactile Reasoning

We thank the reviewer for highlighting the absence of long-horizon tactile evaluation. We additionally evaluated 120 public HapTile trajectories longer than 30 seconds, yielding 360 human-verified questions that require evidence from temporally separated stages. All models receive the same eight-frame input budget, and we report mean accuracy over five evaluation runs.

Model Mean accuracy (%)
Video-LLaVA 50.3
LLaVA-OneVision 53.1
InternVL2.5 55.4
Qwen2.5-VL 57.2
Touch-R1 62.4

These results support long-range integration of tactile evidence over fixed trajectories.

Authors · CommentOpenReview ↗

Closing Comment

We hope that these additional experiments and clarifications address the Area Chair’s and reviewers’ main concerns. We would greatly appreciate any feedback on whether the concerns have been sufficiently resolved or whether any questions remain. We will be glad to provide further explanations or information during the discussion period.

Authors · CommentOpenReview ↗

We sincerely thank Reviewer 8dgR for highlighting GRPO variance, the in-distribution comparison confound, and the absence of long-horizon evaluation. We hope that the five-seed statistical analysis, fine-tuned tactile specialists, same-checkpoint RL baselines, and additional HapTile evaluation address these concerns.

Reviewer zBKYOpenReview ↗
Rating
5/6
Confidence
3/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The authors of the Touch-R1 paper center their work on providing tactile reasoning in tactile-language models. The authors posit that existing works in multimodal LLMs do not use information about tactile sensing to ground their responses. The Touch-R1 model has three stages namely (i) tactile dynamics pre-training, (ii) QA supervised fine-tuning (generate TouchReason-1M multimodal tactile reasoning dataset with four optical tactile sensors), and (iii) rule-based reinforcement learning where the model is trained with a tactile-grounded GRPO objective. Th authors develop TouchReason-Bench to benchmark and evaluate tactile perception, ordinal comparison, visual-tactile conflict and cross-sensor consistency. The 7B version of the Touch-R1 model beats SToLa models by 12.6 pts on the benchmark dataset proposed by the authors and shows improved performance even on VTV150K (given in the appendix). The authors also provide a sufficient number of ablation results for analysis

Strengths and weaknesses

Strengths: The approach to study the grounding of tactile reasoning is well founded. The authors also made use of four different optical sensors (GelSight Mini,, Xense, Tac3D, DM-Tac X) and a well-designed handheld device equipped with force torque sensor and IMU-aided gravity compensation for acquiring tactile samples. The annotation process with human labelers and QA method indicated a well-calibrated approach that had high inter-annotator agreement as well. Even with model evals and ablations, the authors do a pretty good set of comparisons.

Weakness: 1. It is currently unclear if the tactile-language models were all trained on the TouchReason-1M data. It would be good to clarify this explicitly. If not, the authors will benefit from reporting results for baselines fine-tuned on the dataset. 2. Some of the value changes are quite small. It would be helpful to ensure there is some semblance of statistical testing with few seeds 3. It would be helpful to explicitly describe what the 1M samples refers to - it is currently confusing if this is referencing tactile pairs or individual frames. 4. It currently looks like G_tg rewards any distribution change, irrespective of whether it is an improvement or degradation. Equation 5 currently has an unsigned KL and does not have a correctness term. Please check and confirm 5. Fig 5is currently hard to read. Would it be possible to either change the format or convert it to a table?

Questions
  1. How is CSC prevented from rewarding consistent but incorrect answers?
  2. Other points as addressed above
Limitations

Yes

Final justification

The authors have spent time diligently addressing my concerns and added sufficient details and clarification in their rebuttal that makes this an interesting contribution to NeurIPS. I am good to accept it. Thanks to the authors for taking the feedback and working on the updates.

Formatting concerns

The paper does not provide any context to the problem or the proposed models before diving into the details in the first paragraph of the paper. The continuity expectation from an abstract into an introduction does not always hold. So please provide sufficient detail in the introduction section about your proposed work.

4 comments
Authors · CommentOpenReview ↗

Reviewer zBKY

Q1. Were All Compared Models Trained on TouchReason-1M?

We are sorry that the training conditions in the submitted Table 2 were not stated clearly. The submitted table did not use a uniform TouchReason-1M training setting. The closed-source API models were used as prompted references. The public general-purpose VLMs and tactile-specialist models were evaluated using their released checkpoints without additional fine-tuning on TouchReason-1M. Touch-R1, by contrast, was trained on TouchReason-1M through cold-start SFT followed by tactile-grounded RL, with the RL stage initialized from the Qwen TR-SFT checkpoint.

To provide controlled comparisons, we added the following baselines:

Model and training setting OMAE↓ CSC↑ Avg↑
Qwen2.5-VL + TR-SFT 0.46 ± 0.04 52.63 ± 0.82 47.84 ± 0.51
AnyTouch+Qwen + TR-SFT 0.38 ± 0.05 55.42 ± 1.13 51.64 ± 0.72
SToLa-13B + TR-SFT 0.35 ± 0.04 57.14 ± 1.02 53.21 ± 0.83
Qwen2.5-VL + TR-SFT + Vanilla GRPO 0.42 ± 0.09 54.31 ± 1.78 50.13 ± 1.42
Qwen2.5-VL + TR-SFT + DAPO 0.38 ± 0.06 58.24 ± 1.27 52.41 ± 1.12
Qwen2.5-VL + TR-SFT + GSPO 0.33 ± 0.05 61.82 ± 1.21 53.84 ± 0.98
SToLa-13B + TR-SFT + Vanilla GRPO 0.31 ± 0.05 62.53 ± 1.38 54.52 ± 1.18
Touch-R1 0.24 ± 0.02 71.32 ± 0.88 60.12 ± 0.63

The original AnyTouch+Qwen and SToLa rows in Table 2 obtain 45.0 and 47.5 Avg using their released checkpoints. The newly added TouchReason-1M SFT results are 51.64 and 53.21, respectively; these are additional controlled baselines rather than replacements with unexplained numerical changes.

The Qwen-based RL variants and Touch-R1 use the identical Qwen TR-SFT initialization and therefore provide our most controlled objective-level comparisons. AnyTouch and SToLa use the same TouchReason-1M SFT split and evaluation protocol but retain their own architectures and pretrained checkpoints. We will revise Table 2 to report data exposure, SFT initialization, and RL objective explicitly, so prompted, released-checkpoint, same-data, and same-checkpoint comparisons are not conflated.

Q2. Are the Small Ablation Gains Statistically Reliable?

We thank the reviewer for highlighting the uncertainty of the small ablation gains. The repeated runs support the main ablation conclusions, while also showing that the Format and Grounding gains are substantially smaller than the Ordinal and Consistency gains.

We reran the cold-start SFT baseline, Vanilla GRPO, and every cumulative Touch-R1 configuration with five independent seeds. We also performed 10,000 paired bootstrap resamples over the 200 held-out object clusters. For each bootstrap replicate, adjacent configurations are evaluated on the same resampled objects and matched seeds; the 95% interval is computed from the resulting paired differences.

Configuration OMAE↓ CSC↑ Avg↑ ΔAvg [95% CI]
Cold-start SFT 0.46 ± 0.04 52.6 ± 0.8 47.8 ± 0.5 —
Vanilla GRPO 0.42 ± 0.09 54.3 ± 1.8 50.1 ± 1.4 +2.3 [0.8, 3.9]
+ Ordinal 0.31 ± 0.03 56.1 ± 1.0 54.6 ± 0.7 +4.5 [3.1, 5.8]
+ Consistency 0.27 ± 0.03 69.2 ± 1.2 58.3 ± 0.9 +3.7 [2.4, 5.1]
+ Format 0.26 ± 0.02 70.4 ± 1.0 59.2 ± 0.8 +0.9 [0.1, 1.7]
Touch-R1 (+ Grounding) 0.24 ± 0.02 71.3 ± 0.9 60.1 ± 0.6 +0.9 [0.2, 1.6]

Vanilla GRPO has a 1.4-point standard deviation on Avg, confirming that one run was insufficient. We will state explicitly that the table reports cumulative, order-dependent marginal gains rather than an order-independent attribution of the total improvement.

Q3. What Does “1M Samples” Mean?

We are sorry that the term “sample” was unclear. In TouchReason-1M, “1M samples” refers to approximately 1.32 million frame-level, temporally synchronized multimodal observations.

Specifically, each sample corresponds to one acquisition timestamp and contains: (a) one raw tactile image; (b) the corresponding sensor-dependent derived tactile representations, including shear and depth fields for samples from all sensor types, as well as a deformation field for DM-Tac X samples; (c) the temporally aligned force/torque measurement; and (d) the corresponding RealSense observation.

Thus, “1M” is shorthand for approximately 1.32 million synchronized frame-level multimodal observations, rather than the number of interaction sequences or QA instances. Consecutive observations are further grouped into continuous tactile interaction sequences. We will revise the manuscript to explicitly define “sample” and consistently distinguish among synchronized observations, interaction sequences, and QA instances.

Authors · CommentOpenReview ↗

Q4. Does the Original GtgG_{tg} Reward Any Distributional Change, Regardless of Correctness?

We thank the reviewer for identifying this issue. The concern is valid when the submitted unsigned KL is viewed in isolation: it measures distributional change without directly requiring improvement on the correct answer. To examine this concern, we compare it with a directional, correctness-gated grounding objective:

Gtgdir=I[y^T=y∗][log⁡pθ(y∗∣V,T,q)−log⁡pθ(y∗∣V,T~,q)]+−λI[y^T≠y∗,y^T~=y∗].G_{tg}^{\mathrm{dir}}=\mathbb{I}[\hat{y}_{T}=y^{\ast}]\left[\log p_{\theta}(y^{\ast}\mid V,T,q)-\log p_{\theta}(y^{\ast}\mid V,\widetilde{T},q)\right]_+-\lambda\mathbb{I}[\hat{y}_{T}\neq y^{\ast},\hat{y}_{\widetilde{T}}=y^{\ast}].

Here, TT denotes the real tactile input, T~\widetilde{T} denotes the counterfactual tactile input, and y∗y^{\ast} is the reference answer.

In this variant, positive credit requires the real tactile input to produce the correct prediction and increase the reference-answer likelihood relative to the counterfactual input. All other full-model components and evaluation settings are fixed in this comparison.

Grounding objective (all other full-model components fixed) OMAE↓ CSC↑ Avg↑
Directional correctness-gated variant 0.25 70.8 59.7
Submitted unsigned-KL objective (Touch-R1) 0.24 71.3 60.1

The submitted unsigned-KL objective performs better, improving Avg from 59.7 to 60.1. Because answer correctness is already enforced by the task reward, we retain the submitted objective and clarify that GtgG_{tg} is an auxiliary measure of dependence on tactile evidence rather than a standalone correctness reward.

Q5. How Does CSC Avoid Rewarding Consistent but Incorrect Predictions?

We thank the reviewer for pointing out this failure mode. The submitted consistency reward could assign positive credit to identical incorrect predictions when viewed in isolation. To examine this concern, we compare it with the following correctness-gated objective:

Rcscorr=I[ci∧cj]C(ri,rj)−λwI[y^i=y^j≠y∗]−λaI[ci⊕cj].R_{cs}^{\mathrm{corr}}=\mathbb{I}[c_i\land c_j]C(r_i,r_j)-\lambda_w\mathbb{I}[\hat{y}_i=\hat{y}_j\neq y^{\ast}]-\lambda_a\mathbb{I}[c_i\oplus c_j].

In this variant, positive credit requires both predictions to be correct, while identical incorrect and asymmetric predictions are penalized. All other full-model components and evaluation settings are fixed in this comparison.

Consistency objective (all other full-model components fixed) OMAE↓ CSC↑ Avg↑
Correctness-gated consistency variant 0.25 70.7 59.2
Submitted consistency objective (Touch-R1) 0.24 71.3 60.1

The submitted consistency objective performs better, improving Avg from 59.2 to 60.1. Because answer correctness is enforced separately by the task reward, we retain the submitted objective and clarify that consistency is an auxiliary signal rather than a standalone measure of correctness.

Q6. Readability of Figure 5 and the Introduction

We thank the reviewer for these helpful presentation suggestions. We will replace Figure 5 with a table and reorganize the Introduction so that the problem and overall framework are explained before the technical objectives. The full scaling curves will be moved to the appendix. In the revised Introduction, we will first define the conflict between visual priors and tactile evidence, then introduce TouchReason-1M and TouchReason-Bench, summarize the three-stage training pipeline, and finally present the individual reward components.

Authors · CommentOpenReview ↗

Closing Comment

We hope that these additional experiments and clarifications address the Area Chair’s and reviewers’ main concerns. We would greatly appreciate any feedback on whether the concerns have been sufficiently resolved or whether any questions remain. We will be glad to provide further explanations or information during the discussion period.

Authors · CommentOpenReview ↗

We sincerely thank Reviewer zBKY for the constructive comments on training fairness, statistical reliability, dataset definition, reward design, and presentation. We hope that the added same-data and same-checkpoint baselines, five-seed statistical analysis, clarification of “1M samples,” controlled objective comparisons, and planned presentation revisions address these concerns.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Missing a submission?

Loading the discussion…