potentialpaper

Anatomy-Preserving Unpaired Medical Image Translation via Shared Latent Anchoring

Zhilin Zou, Hieu Le, Saumya Gupta, Jingyi Xu, Prateek Prasanna, Chao Chen

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

Abstract. Unpaired medical image-to-image translation requires synthesizing target-modality images from source-modality images without aligned supervision. Existing methods learn a direct source-to-target mapping that entangles structure preservation and appearance generation within a single model, often distorting clinically meaningful anatomy in the translated output. We argue that these two objectives should be decoupled entirely: anatomical structure should be captured independently of generation, and the generator should operate only on a frozen structural representation. To this end, we propose a two-stage framework for unpaired medical image translation. In the first stage, we learn a shared structure space by training a structure encoder-decoder on source images, target images, and structural masks jointly, using mask reconstruction to anchor the latent space to modality-agnostic anatomy. For source images without mask annotations, a target-domain memory bank provides soft structural supervision via prototype retrieval. In the second stage, a conditional flow model learns to render target-domain appearance under fixed structural conditions. This ensures the generator inherits target appearance statistics and can focus entirely on structural conditioning rather than learning appearance from scratch. We validate our framework on OCT-to-OCTA synthesis and brain MR-to-CT translation. Our method outperforms all unpaired baselines on both tasks and, despite requiring no paired supervision, also surpasses paired baselines, improving PSNR by up to 11.2% and SSIM by up to 26.4% on OCT-to-OCTA, and achieving consistent gains across whole-image, soft-tissue, and bone regions on MR-to-CT. The project repository is available on github.com/RNZZL/Anatomy-Preserving-Unpaired-Medical-Image-Translation-via-Shared-Latent-Anchoring.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
29 Apr 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:43 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

While reviewers agreed that the paper addresses a clinically meaningful problem with a coherent two-stage design that logically separates structure preservation from appearance generation, they also raised serious concerns about the paper's soundness and significance: (1) the reliance on target-domain structural masks constitutes a strong form of supervision that is insufficiently distinguished from fully unpaired settings, and the resulting performance gains over paired baselines lack fair comparison given unequal access to structural cues; (2) statistical rigor is weak—confidence intervals appear to ignore patient-level correlation, and results lack multi-seed validation, undermining reproducibility; (3) clinical utility remains unproven, with no downstream task evaluation or expert assessment to confirm that improved metrics translate to diagnostic value.

Final justification

After rebuttal, one reviewer raised the score. Overall, all three reviews are positive, I would like to recommend accepting this paper.

Area Chair uJ1L · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

While reviewers agreed that the paper addresses a clinically meaningful problem with a coherent two-stage design that logically separates structure preservation from appearance generation, they also raised serious concerns about the paper's soundness and significance: (1) the reliance on target-domain structural masks constitutes a strong form of supervision that is insufficiently distinguished from fully unpaired settings, and the resulting performance gains over paired baselines lack fair comparison given unequal access to structural cues; (2) statistical rigor is weak—confidence intervals appear to ignore patient-level correlation, and results lack multi-seed validation, undermining reproducibility; (3) clinical utility remains unproven, with no downstream task evaluation or expert assessment to confirm that improved metrics translate to diagnostic value.

Final justification

After rebuttal, one reviewer raised the score. Overall, all three reviews are positive, I would like to recommend accepting this paper.

1 comment
Authors · CommentOpenReview ↗

Response to the Area Chair’s Main Concerns

We thank the Area Chair for the careful assessment and constructive summary. We briefly address the three primary concerns below and refer to the corresponding reviewer responses for full experimental details.

(1) Structural supervision and comparison fairness. We thank the AC for highlighting this distinction. As detailed in Reviewer StyX, Issues S1.1, S1.2, and S4, we now explicitly characterize our setting as unpaired at the image level with one-sided target-domain structural supervision, rather than as fully unpaired translation. The masks are generated automatically in our evaluated tasks, and training with automatically extracted OCTA masks yields nearly unchanged translation performance. We also clarify the supervision and architectural settings of all baselines and will explicitly report their respective annotation requirements in the main tables.

(2) Statistical rigor and reproducibility. We thank the AC for raising this concern. As detailed in Reviewer StyX, Issue S2 and Reviewer 6DVC, Issue D1, all evaluation splits and confidence intervals are defined at the patient/case level: OCT-to-OCTA uses case-level bootstrap, while MR-to-CT metrics are first averaged within each patient before computing confidence intervals. We additionally report three independent OCT-to-OCTA training runs and clarify that no paired validation information is used for checkpoint or hyperparameter selection.

(3) Clinical utility and independent validation. We thank the AC for highlighting this point. As detailed in Reviewer Xoww, Issue X2 and Reviewer 6DVC, Issue D2, we add independent downstream classification, vessel-based evaluation using a frozen evaluator, and a blinded reader study. These analyses provide evidence that our method better preserves disease-discriminative information and clinically relevant vascular structures beyond the training objective. We emphasize that these results support reduced structural inconsistencies, but external validation and expert assessment remain necessary before clinical deployment.

We hope these clarifications and additional experiments address the principal concerns regarding supervision, statistical validity, reproducibility, and clinical relevance.

Reviewer XowwOpenReview ↗
Rating
5/6
Confidence
5/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
4/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

In this paper, the authors propose a two-stage framework for Medical Image Translation. The authors state that current work is limited by its reliance on paired datasets and its tendency to entangle structural preservation with appearance generation, which often distorts underlying clinical anatomy. To overcome these limitations, the framework explicitly decouples these objectives by first constructing a shared structural latent space via an encoder-decoder. It also utilizes a Structural Memory Bank to provide soft structural supervision for source images lacking annotations. In the second stage, a conditional flow model is trained to synthesize Medical Images using the frozen structural representations from the first stage as fixed guidance. They evaluate their method on the OCTA-500 and SynthRAD2023 datasets for OCT-to-OCTA and MR-to-CT translation tasks and showcase superior performance compared to both paired and unpaired baselines.

Strengths and weaknesses
  • This framework guides the Medical Image translation process with soft structural supervision, which helps prevent the distortion of clinical anatomy

  • With the introduction of the Structural Memory Bank, the authors provide a solution to the need for paired datasets and the need for source domain masks

  • Great Quantitative results. The method outperforms both unpaired and paired baselines across both tasks

  • The evaluation relies on controlled, curated datasets: OCTA-500 and SynthRAD2023. Both of these datasets provide controlled environments and fail to fully reflect the complex domain shifts present in the real world where we have diffent scanners and acquisition protocols

  • There is no clear downstream task evaluation to fully demonstrate the clinical utility of the method. While we get superior quantitative results and really niche qualitative result examples, we are still not sure how this method helps in diagnosis.

Questions

How robust is the shared structure of the latent space when subjected to severe out-of-distribution shifts, such as multi-institutional data? What is the impact of this framework on a downstream evaluation task?

Limitations

The framework was evaluated on relatively controlled datasets. While the cases were split into non-overlapping sets, this setup does not fully capture the complex, real-world variations encountered across different institutions, scanners, or patient populations.

The framework's central claim of preserving "clinically meaningful" anatomy is supported only by pixel-level fidelity metrics. No downstream or clinical validation is provided, so the clinical utility of the translation is not fully demonstrated.

Final justification

I am pleased with the author responses

Formatting concerns

n/a

3 comments
Authors · RebuttalOpenReview ↗
Rebuttal

Response to Reviewer Xoww

Thank you for recognizing the structural-preservation motivation and strong quantitative results, and for the constructive questions. W, Q, and L denote the numbered Weakness, Question, and Limitation items in your review, respectively.

Issue X1. Generalization under real-world and multi-institutional domain shifts (W1, Q1, L1)

Response:

We thank the reviewer for highlighting generalization under institutional domain shifts. We add a center-held-out evaluation on SynthRAD2023. All evaluated methods are retrained using only data from centers A and B (UMC Utrecht and UMC Groningen) and tested without adaptation on the unseen center C (Radboudumc). No image, annotation, or memory-bank prototype from center C is used during training or model selection.

As shown in Table 9, our method achieves the best performance across all whole-image, soft-tissue, and bone-region metrics, outperforming both unpaired SynDiff and paired DDBM. The gains are particularly pronounced in the bone region, where PSNR/SSIM improves from 14.10/67.4914.10/67.49 for DDBM to 17.14/80.4517.14/80.45.

These results provide direct evidence of robustness under an unseen institutional shift. Nevertheless, one held-out center cannot cover all scanner, protocol, vendor, or population variations, and broader multi-institutional validation remains necessary.

Table 9. Center-held-out evaluation on the SynthRAD2023 brain MR-to-CT task. All methods are retrained using centers A and B only and evaluated without adaptation on the unseen center C. Results are patient-level means. W, S, and B denote whole image, soft tissue, and bone, respectively.

Method Paired W-PSNR ↑\uparrow W-SSIM ↑\uparrow S-PSNR ↑\uparrow S-SSIM ↑\uparrow B-PSNR ↑\uparrow B-SSIM ↑\uparrow
SynDiff ×\times 24.1024.10 94.6894.68 23.1823.18 50.7150.71 13.7113.71 62.3162.31
DDBM ✓\checkmark 25.1325.13 95.7995.79 23.2723.27 58.7158.71 14.1014.10 67.4967.49
Ours ×\times 27.9827.98 97.0597.05 27.1527.15 59.1759.17 17.1417.14 80.4580.45

Issue X2. Downstream diagnostic value and clinically meaningful anatomy (W2, Q2, L2)

Response:

We thank the reviewer for requesting downstream validation. We train a normal-versus-abnormal classifier exclusively on acquired OCTA images from the 450-case training partition and apply it, without adaptation, to acquired and translated OCTA images from the same 50 held-out cases.

As shown in Table 10, our method achieves the highest balanced accuracy among the translated images and most closely preserves the classifier behavior on acquired OCTA, with the lowest probability deviation and decision-flip rate and the highest probability correlation. Its probability deviation is also significantly lower than those of all reported baselines after Holm correction.

These results provide independent downstream evidence that our method better preserves patient-specific disease-discriminative information beyond pixel-level fidelity. Complementary independent vessel evaluation and blinded reader assessment are reported in Reviewer 6DVC, Issue D2. However, this algorithmic evaluation does not establish clinical diagnostic equivalence or improved human decision-making; external validation and expert assessment remain necessary.

Table 10. Independent downstream normal-versus-abnormal classification on the fixed 50-case OCTA-500 test set. The classifier is trained exclusively on acquired OCTA images from the 450-case training partition and is frozen for all evaluations. AUROC and balanced accuracy are evaluated against the disease labels. The remaining metrics measure agreement with the classifier outputs obtained on acquired OCTA. ∣Δp∣\lvert\Delta p\rvert denotes the absolute difference between classifier probabilities on translated and acquired OCTA; Spearman ρ\rho measures their rank correlation; and flip rate denotes the proportion of cases whose binary prediction changes relative to acquired OCTA. The 95% confidence intervals for AUROC and balanced accuracy are computed using case-level bootstrap. The final column reports Holm-adjusted paired Wilcoxon tests comparing ∣Δp∣\lvert\Delta p\rvert for each baseline against our method.

(a) Classification performance

Input to frozen classifier AUROC ↑\uparrow Bal. Acc. ↑\uparrow
Acquired OCTA (reference) 0.928 [0.848, 0.984]0.928\,[0.848,\,0.984] 0.850 [0.750, 0.944]0.850\,[0.750,\,0.944]
Ours 0.887 [0.740, 0.995]0.887\,[0.740,\,0.995] 0.867 [0.762, 0.958]0.867\,[0.762,\,0.958]
MuTri 0.702 [0.555, 0.840]0.702\,[0.555,\,0.840] 0.533 [0.469, 0.612]0.533\,[0.469,\,0.612]
SynDiff 0.888 [0.773, 0.976]0.888\,[0.773,\,0.976] 0.533 [0.468, 0.612]0.533\,[0.468,\,0.612]
UNSB 0.525 [0.353, 0.700]0.525\,[0.353,\,0.700] 0.550 [0.500, 0.625]0.550\,[0.500,\,0.625]
MUNIT 0.455 [0.297, 0.619]0.455\,[0.297,\,0.619] 0.500 [0.500, 0.500]0.500\,[0.500,\,0.500]

(b) Agreement with acquired OCTA

Input to frozen classifier ∣Δp∣\lvert\Delta p\rvert ↓\downarrow Spearman ρ\rho ↑\uparrow Flip rate ↓\downarrow pΔpp_{\Delta p} vs. Ours
Ours 0.1320.132 0.7660.766 0.080.08 --
MuTri 0.2880.288 0.4830.483 0.300.30 0.0160.016
SynDiff 0.3150.315 0.4580.458 0.300.30 0.0070.007
UNSB 0.3550.355 0.0070.007 0.280.28 <0.001<0.001
MUNIT 0.4160.416 −0.236-0.236 0.280.28 <0.001<0.001
Reviewer Xoww · CommentOpenReview ↗

thank you

I would like to thank the authors for their rebuttal. The extra information that they provided in this short time is highly appreciated and commendable. I have carefully read your responses both to me, the other reviewers and the Area Chair and I am very satisfied with the proposed revisions.

To be more precise, you have answered both of my concerns:

  • Method Generalization: Your extra experiment on the SynthRAD2023 dataset answered my concerns on unseen institutional shifts. I agree that a more thorough study needs to be done to get a broader image, but, in my opinion, this does not take away from the paper.
  • Downstream Clinical Validation: The additional OCTA-500 experiment with the frozen classifier has clearly demonstrated that your method preserves disease relevant information better than the baselines. I am satisfied by this result as I believe it would make a valuable addition to the paper. Furthermore, I am happy to read the clarifications you provided to the other reviewer's excellent comments. Given these substantial improvements and your commitment to add these new results in the final manuscript, I would be more than happy to raise my score.
Authors · CommentOpenReview ↗

Thank You for Your Thoughtful Feedback

Thank you very much for your thoughtful follow-up and encouraging feedback. We greatly appreciate the time you took to carefully review our responses and additional results. We are pleased that the new experiments and clarifications have addressed your concerns. We will incorporate these results and the corresponding revisions into the final manuscript.

Reviewer 6DVCOpenReview ↗
Rating
5/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This manuscript proposes an unpaired approach to image-to-image translation, decoupling the training of a learned shared structure space jointly trained on source and target images, along with structural masks, from a conditional flow model that renders the appearance of target images. Using two datasets (2D retinal images and an MRI-to-CT translation), the authors demonstrate their approach to achieve superior Dice and technical image quality metrics compared to paired and unpaired baseline methods.

Strengths and weaknesses

This work has a number of strengths, addressing the impactful challenge of synthesizing missing modalities. The two-stage approach is logical and well-motivated, addressing the critical issue of maintaining structure by using anatomical masks and structure-aware metrics. The two datasets used to evaluate the method are varied and demonstrate the range of applications in which the technique could be used. The work also explicitly addresses hallucinations, mitigating them through a structural consistency loss.

A few weaknesses are noted. The experimental design would benefit from clearer reporting of how the confidence intervals are generated. Although the dataset split appears to be performed at the subject level, the reported confidence intervals may be computed over individual 2D slices, which are highly correlated within a patient and could therefore overstate statistical precision. Patient-level confidence intervals, subject-level bootstrapping, or cross-validation would provide stronger evidence. Second, while the approach encourages structural consistency, the structural loss relies on the same learned encoder-decoder and does not independently establish anatomical correctness or absence of hallucinations. Finally, additional task-driven evaluation using external segmentation/measurement tools, expert assessment, or task-specific metrics such as vessel quantification or CT anatomical segmentation would strengthen the clinical validity of the claims.

Questions
  1. Could the authors clarify whether the train/test split is performed at the patient/case level and how the 95% confidence intervals are computed?
  2. How do the authors verify that hallucinations are actually reduced?
  3. Have the authors evaluated whether the synthesized images improve downstream clinical and algorithmic tasks?
Limitations

While the method explicitly aims to mitigate hallucinations, its limitations are not fully characterized. In particular, the structural consistency loss relies on the same learned encoder-decoder and does not independently verify anatomical correctness. Additionally, the use of a structural memory bank could bias outputs toward target-domain anatomies, potentially reducing subject-specific fidelity or introducing subtle hallucinations. More explicit acknowledgement of these limitations would strengthen the paper.

Final justification

The authors have been responsive to the critiques and have provided additional experimental results that address concerns raised by the reviewers. The authors provide additional analyses on hallucinations and transparently acknowledge that, although their frequency is reduced, they are not entirely eliminated.

Formatting concerns

None

3 comments
Authors · RebuttalOpenReview ↗
Rebuttal

Response to Reviewer 6DVC

Thank you for the positive assessment and constructive suggestions. W, Q, and L denote the numbered Weakness, Question, and Limitation items in your review, respectively.

Issue D1. Patient-level uncertainty and confidence intervals (W1, Q1)

Response:

We thank the reviewer for raising this statistical concern. All evaluation splits are defined at the patient/case level.

For OCT-to-OCTA, the 50 held-out cases are treated as 50 independent case-level units, and the 95% confidence intervals in the main results are computed by case-level bootstrap over the 50 held-out cases. For MR-to-CT, slice-level metrics are first averaged within each of the 20 held-out patients, and two-sided 95% Student's tt intervals are then computed across the patient-level values rather than directly over correlated slices (Table 4).

Training-seed variability is evaluated separately from test-cohort uncertainty. Reviewer StyX, Issue S2 reports the three-seed OCT-to-OCTA results and the hyperparameter-selection protocol.

Table 4. Patient-level uncertainty of our method on MR-to-CT. Slice-level measurements are first averaged within each of the 20 held-out patients. The 95% CIs are two-sided Student's tt intervals computed over these patient-level values.

Region PSNR (dB), Mean PSNR 95% CI SSIM (%), Mean SSIM 95% CI
Whole image 28.6428.64 [27.72, 29.57][27.72,\,29.57] 97.1597.15 [96.60, 97.67][96.60,\,97.67]
Soft tissue 28.4628.46 [27.77, 29.14][27.77,\,29.14] 69.2669.26 [65.60, 72.92][65.60,\,72.92]
Bone 17.6117.61 [16.81, 18.41][16.81,\,18.41] 80.3080.30 [76.08, 84.54][76.08,\,84.54]

Issue D2. Independent hallucination verification and downstream clinical validity (W2, W3, Q2, Q3, L1, L2, L4)

Response:

We thank the reviewer for emphasizing the need for verification independent of the internal structural loss. We add two such analyses: a frozen vessel evaluator that is separate from the translation model and a blinded reader study on 10 held-out OCT-to-OCTA cases.

As shown in Table 5, our method achieves the highest observed Vessel Dice and the lowest density, hallucination, omission, and connected-component errors, while achieving comparable clDice [1] to MuTri. Table 6 further shows that our method achieves the highest clinical vascular fidelity and diagnostic acceptability and the lowest perceived missing- and unsupported-vessel severity.

Reviewer Xoww, Issue X2 additionally reports a downstream normal-versus-abnormal classification experiment, in which our method better preserves disease-discriminative information.

Together, these results support reduced, rather than eliminated, structural inconsistencies. They do not establish hallucination-free or clinically deployable synthesis; external validation, uncertainty estimation, and expert oversight remain necessary.

Table 5. Independent vessel-based evaluation on the held-out OCT-to-OCTA test set. All vessel masks are predicted using the same frozen evaluator SauxS_{\mathrm{aux}}, which is separate from the translation model and is not used to train or select any evaluated method. Results are reported as mean ±\pm 95% case-level bootstrap CI half-width over the 50 held-out cases. Higher is better for Vessel Dice and clDice; lower is better for all error metrics. Bold indicates the best mean result.

Method Vessel Dice ↑\uparrow clDice ↑\uparrow Density Err. ↓\downarrow Halluc. ↓\downarrow Omiss. ↓\downarrow #CC Err. ↓\downarrow
MUNIT 0.501±0.0290.501\pm0.029 0.493±0.0320.493\pm0.032 0.0304±0.00370.0304\pm0.0037 0.362±0.0300.362\pm0.030 0.584±0.0290.584\pm0.029 28.9±5.428.9\pm5.4
MuTri 0.787±0.0170.787\pm0.017 0.818±0.0190.818\pm0.019 0.0118±0.00260.0118\pm0.0026 0.162±0.0100.162\pm0.010 0.253±0.0280.253\pm0.028 25.3±7.325.3\pm7.3
Ours 0.797±0.0260.797\pm0.026 0.818±0.0270.818\pm0.027 0.0113±0.00310.0113\pm0.0031 0.152±0.0140.152\pm0.014 0.243±0.0360.243\pm0.036 17.8±6.017.8\pm6.0

Table 6. Blinded reader study on 10 held-out OCT-to-OCTA cases evaluated by two readers. Each reader assesses anonymized outputs relative to the same source OCT and acquired OCTA. Fidelity denotes clinical vascular fidelity, and Acceptability denotes diagnostic acceptability; both are scored from 1 to 5, where higher is better. Missing and Unsupported denote missing-vessel and unsupported-vessel severity, respectively; both are scored from 0 to 3, where lower is better. Results are reported as mean ±\pm 95% case-level bootstrap CI half-width, with both reader ratings retained within each resampled case. Bold indicates the best mean result.

Method Fidelity ↑\uparrow Missing ↓\downarrow Unsupported ↓\downarrow Acceptability ↑\uparrow
SynDiff 2.75±0.442.75\pm0.44 2.00±0.282.00\pm0.28 1.30±0.251.30\pm0.25 2.50±0.442.50\pm0.44
MuTri 3.00±0.313.00\pm0.31 1.80±0.281.80\pm0.28 1.20±0.151.20\pm0.15 2.85±0.422.85\pm0.42
Ours 3.65±0.563.65\pm0.56 1.35±0.461.35\pm0.46 0.65±0.200.65\pm0.20 3.50±0.693.50\pm0.69

Issue D3. Memory-bank bias and subject-specific fidelity (L3)

Response:

We thank the reviewer for raising this concern. Although the memory bank is used only during training, retrieval could still influence the learned generator. The Stage-II self branch anchors target-domain rendering using reliable target-mask-derived conditions, while the cross branch uses retrieved images as structure-compatible soft endpoints rather than subject-specific anatomical labels. No memory-bank entry is used at inference.

We evaluate potential prototype bias by comparing each output's Own-subject Dice with its post-hoc Prototype Affinity and their difference, Subject Margin. As shown in Table 7, our method achieves higher Own-subject Dice than the bank-free MuTri control, with comparable Prototype Affinity and a slightly larger positive Subject Margin. The same trend holds for the ten lowest-confidence retrieval cases, and all 50 test outputs have positive margins. Even the five outputs with the smallest margins remain globally closer to their own annotations than to the retrieved prototypes (Table 8).

Complementary independent evaluation in Issue D2 also shows lower average hallucination, omission, and connected-component errors than MuTri. Thus, we find no evidence of wholesale replacement of subject-specific anatomy by retrieved prototypes. However, subtle local retrieval-induced errors cannot be excluded, and local hallucination and omission remain explicit limitations.

Table 7. Post-hoc subject-versus-prototype analysis on the held-out OCT-to-OCTA test set. For each subject, the proposed retrieval procedure defines a fixed set of top-KK training prototypes and weights. Acquired OCTA and MuTri do not use the memory bank during generation; their affinity to the same prototypes is evaluated only as post-hoc calibration. Prototype Affinity is the retrieval-weighted mean Dice to the individual retrieved masks, and Subject Margin is Own-subject Dice minus Prototype Affinity. Retrieval confidence measures source-to-bank similarity rather than translation difficulty. All 50 evaluated cases have positive Subject Margins. Bold indicates the best result among translation methods. Results are reported as mean ±\pm 95% case-level bootstrap CI half-width.

Subset Image/Method Own Dice ↑\uparrow Proto. Affinity Margin ↑\uparrow
All 50 Acquired OCTA 0.859±0.0080.859\pm0.008 0.124±0.0040.124\pm0.004 0.735±0.0090.735\pm0.009
All 50 MuTri 0.787±0.0170.787\pm0.017 0.112±0.0030.112\pm0.003 0.675±0.0170.675\pm0.017
All 50 Ours 0.797±0.0260.797\pm0.026 0.118±0.0040.118\pm0.004 0.679±0.0250.679\pm0.025
Low-conf. 10 Acquired OCTA 0.867±0.0160.867\pm0.016 0.111±0.0060.111\pm0.006 0.755±0.0210.755\pm0.021
Low-conf. 10 MuTri 0.810±0.0390.810\pm0.039 0.104±0.0050.104\pm0.005 0.706±0.0400.706\pm0.040
Low-conf. 10 Ours 0.827±0.0380.827\pm0.038 0.107±0.0040.107\pm0.004 0.720±0.0410.720\pm0.041

Table 8. Case-level analysis of the five outputs with the smallest Subject Margins. Cases 1--5 are ordered from the smallest to the largest margin. All margins remain positive, indicating that even the least favorable outputs are globally closer to their subject-specific annotations than to the retrieved training prototypes. Hallucination and omission quantify local unsupported vessels and missing subject vessels, respectively.

Case Own Dice ↑\uparrow Prototype Affinity Subject Margin ↑\uparrow Halluc. ↓\downarrow Omiss. ↓\downarrow
Case 1 0.4530.453 0.0930.093 +0.360+0.360 0.3620.362 0.6490.649
Case 2 0.5970.597 0.1230.123 +0.474+0.474 0.2670.267 0.4970.497
Case 3 0.6380.638 0.1110.111 +0.527+0.527 0.1810.181 0.4770.477
Case 4 0.6710.671 0.0990.099 +0.572+0.572 0.1860.186 0.4290.429
Case 5 0.6810.681 0.1080.108 +0.573+0.573 0.1840.184 0.4150.415

References

[1] clDice - A Novel Topology-Preserving Loss Function for Tubular Structure Segmentation. CVPR 2021.

Reviewer 6DVC · CommentOpenReview ↗

Thank you

Thank you for providing additional clarification and experimental results addressing the concerns raised related to hallucinations and training bias. I have no further concerns about the issues raised by reviewers.

Authors · CommentOpenReview ↗

Thank You for the Positive Follow-Up

We thank the reviewer for the positive follow-up and for confirming that our additional clarifications and experiments address the concerns regarding hallucinations and training bias. We greatly appreciate the careful assessment and are glad that no further concerns remain.

Update to Issue D2: Expanded five-reader study

Since posting our initial response, we have expanded the blinded reader study from two to five readers, including three retina specialists with 2--10 years of experience interpreting OCT/OCTA.

The expanded evaluation remains consistent with our original findings: our method achieves the highest clinical vascular fidelity and diagnostic acceptability, while yielding the lowest perceived missing- and unsupported-vessel severity among the evaluated methods.

Updated Table 6. Expanded blinded reader study on 10 held-out OCT-to-OCTA cases evaluated by five readers. Each reader independently assesses anonymized outputs relative to the same source OCT and acquired OCTA. Fidelity and Acceptability are scored from 1 to 5, where higher is better; Missing and Unsupported are scored from 0 to 3, where lower is better. Results are reported as mean ±\pm 95% case-level bootstrap CI half-width, with all five reader ratings retained within each resampled case. Three readers are retina specialists with 2--10 years of experience interpreting OCT/OCTA. Bold indicates the best mean result.

Method Fidelity ↑\uparrow Missing ↓\downarrow Unsupported ↓\downarrow Acceptability ↑\uparrow
SynDiff 2.74±0.342.74\pm0.34 1.74±0.281.74\pm0.28 1.42±0.241.42\pm0.24 2.64±0.392.64\pm0.39
MuTri 3.00±0.173.00\pm0.17 1.64±0.151.64\pm0.15 1.18±0.161.18\pm0.16 2.94±0.212.94\pm0.21
Ours 3.38±0.603.38\pm0.60 1.42±0.491.42\pm0.49 0.88±0.290.88\pm0.29 3.38±0.753.38\pm0.75
Reviewer StyXOpenReview ↗
Rating
4/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
2/4
Originality
2/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The manuscript proposes a two-stage framework for unpaired medical image translation. In the first stage, it learns a modality-agnostic anatomical representation through a shared structure encoder-decoder, target-domain masks, optional coarse source masks, and a structural memory bank that retrieves target-domain prototypes for source-side supervision. In the second stage, the learned structure module is frozen and used to condition a flow-based generator for target-modality synthesis. The method is evaluated on OCT-to-OCTA and brain MR-to-CT translation, with comparisons against representative unpaired and paired baselines, including GAN-based, contrastive, disentanglement-based, diffusion-based, and bridge-based methods.

Strengths and weaknesses

Strengths:

1.The motivation is clear and clinically meaningful. Medical image translation requires preserving anatomical content while changing modality-specific appearance, and the proposed separation between structure representation and target appearance generation is a reasonable design choice.

2.The technical pipeline is coherent. The shared structure space, prototype-based memory bank, frozen structure encoder, and conditional flow model are connected in a logical way, rather than being a loose combination of components.

Weaknesses:

1.The method depends on target-domain structural masks and sometimes optional coarse source masks. This is a meaningful form of supervision, even though the image pairs are unpaired. The manuscript should more clearly distinguish between unpaired image supervision and reliance on target-side structural annotations.

2.The comparison with paired baselines is striking, since the proposed unpaired method outperforms several paired methods. This result may be valid, but it requires more analysis. The authors should clarify whether paired baselines receive comparable structural information, whether model capacity is matched, and whether all baselines are tuned with similar care.

3.The experiments are conducted within curated datasets and controlled acquisition settings. More challenging cross-site, cross-scanner, or protocol-shift evaluations would make the generalization argument stronger.

4.The reported confidence intervals appear to be computed over test samples, but it is not clear whether variability across training seeds is included. Multiple-run results would improve the reliability of the empirical conclusions.

5.The clinical relevance of the generated images is not fully evaluated. PSNR, SSIM, Dice, and visual comparisons are helpful, but downstream diagnostic evaluation, expert assessment, or uncertainty analysis would better support the medical imaging motivation.

6.The related work discussion could better cover recent bridge-based methods for unpaired restoration and translation. In particular, Degradation-Aware Dynamic Schrödinger Bridge for Unpaired Image Restoration seems relevant to the broader setting of unpaired image restoration under domain degradation. A brief discussion would help clarify whether the main novelty here lies in anatomical anchoring, target-side structural supervision, the memory-bank mechanism, or the conditional flow formulation.

Questions

1.How sensitive is the proposed method to the quality of target-domain structural masks? Would performance degrade significantly if the masks were generated by a noisy automatic segmentation model?

2.Do all baselines receive access to comparable structural information? If not, could the authors include a stronger comparison where competitive baselines are also conditioned on available masks?

3.How were hyperparameters selected in the unpaired setting? Was any paired validation information used during model selection? Can the authors report results across multiple random seeds for the main tables?

4.For the memory bank, can incorrect prototype retrieval introduce biased or anatomically inconsistent target references? A failure-case analysis would be useful.

5.How does the method perform under scanner, institution, or acquisition-protocol shifts?

6.What are the inference cost, memory footprint, and sampling time of the conditional flow generator compared with the baselines?

7.Could the authors clarify the relationship between their method and recent degradation-aware Schrödinger bridge methods for unpaired image restoration, such as Degradation-Aware Dynamic Schrödinger Bridge for Unpaired Image Restoration? A short discussion would help better position the proposed method relative to bridge-based unpaired restoration approaches.

Limitations

The paper acknowledges that the current experiments are conducted on curated datasets and may not fully reflect real-world domain shifts across institutions, scanners, protocols, or patient populations. I agree with this limitation and believe it is important. In addition, the approach relies on target-domain structural annotations, which may be expensive or unavailable for some medical translation tasks. The experiments are also based on 2D projections or slices, while many clinical imaging applications require volumetric consistency. Finally, although the method improves structural preservation, synthetic medical images may still contain missing or hallucinated anatomy, so clinical deployment would require external validation, uncertainty estimation, and expert oversight.

Final justification

Authors solved my concerns, so I maintain the score

Formatting concerns

No

2 comments
Authors · RebuttalOpenReview ↗
Rebuttal

Thank you for the feedback. W/Q/L mean Weakness/Question/Limitation.

Issue S1.1 Structural supervision (W1, W2, Q2, L2)

We thank the reviewers for highlighting this distinction. Our method uses (IA,IB,MB)(I_A, I_B, M_B), where IAI_A and IBI_B are unpaired images from domains AA and BB, respectively, and MBM_B is a structural mask of IBI_B. To the best of our knowledge, our method is the first unpaired cross-modality translation framework requiring only target-domain structural masks MBM_B, without cross-domain image pairs.

However, we must note that the required structural masks are easy to obtain and do not require manual annotation. In our experiments, they are generated automatically: brain CT masks are produced using TotalSegmentator [1] (see Appendix C in the main paper), while Issue S4 of this rebuttal evaluates automatically extracted OCTA masks. Although these masks achieve vessel/FAZ Dice scores of only 81.65±3.1081.65\pm3.10/80.34±13.3080.34\pm13.30, respectively, they yield nearly unchanged translation performance.

In essence, our method is unpaired at the image level but uses one-sided target-domain structural supervision. This setting does not require subject-level correspondence, subject-matched scans, or cross-modal registration. The optional source mask is also generated automatically, and the method requires neither masks nor memory-bank retrieval at inference. We will revise the manuscript to clearly state this supervision setting throughout the paper and distinguish it from both paired and fully unpaired methods.

Issue S1.2 Baseline comparisons: supervision, architectures, training and evaluation pipelines (W1, W2, Q2, L2)

  • For all baselines, we use the official source code and recommended configurations without modifying their original architectures.
  • All methods are evaluated using the same data splits, image resolution, preprocessing, and evaluation protocol.
  • To make the differences in supervision explicit, we will add an “Annotation” column to Tables 1 and 2 in the main paper, specifying the supervision required by each method, e.g., paired images, unpaired images, or unpaired images + automatically generated pseudo-structural masks (our case).

We will revise the manuscript accordingly to make these differences explicit and ensure that the comparisons are interpreted in the context of their respective supervision and architectural settings.

Issue S2. Statistical rigor, hyperparameter selection, and multi-seed validation (W4, Q3)

Please refer to Reviewer 6DVC, Issue D1 for the patient/case-level split and confidence-interval protocol.

For OCT-to-OCTA, we repeat our full pipeline with three seeds. Each metric is averaged over the same 50 held-out cases, and Table 1 reports the mean and standard deviation across the three case-averaged results. Due to rebuttal-time and computational constraints, multi-seed evaluation is restricted to OCT-to-OCTA.

No paired validation data are used for checkpoint or hyperparameter selection. Stage I and Stage II use the final 10K- and 80K-step checkpoints. Hyperparameters are fixed using unpaired objectives and training stability; paired-data ablations are post-hoc sensitivity analyses and are not used for model selection.

Table 1. Multi-seed OCT-to-OCTA. Metrics are averaged over 50 cases/run and reported as mean ± seed SD over three runs.

Region PSNR (dB), Mean ±± Seed SD SSIM (%), Mean ±± Seed SD
Whole image 19.03±0.0319.03±0.03 64.50±0.4264.50±0.42
Vessel 18.89±0.0818.89±0.08 75.59±0.4675.59±0.46
FAZ 20.49±0.0220.49±0.02 35.03±0.0235.03±0.02

Issue S3. Clinical relevance, downstream utility, and independent verification of hallucination reduction (W5, L4)

We add three analyses beyond image-similarity metrics. Reviewer 6DVC, Issue D2 reports independent verification using a frozen vessel evaluator and a blinded reader study. Reviewer Xoww, Issue X2 reports a downstream normal-versus-abnormal classification experiment.

Together, these evaluations show improved vessel fidelity, lower perceived and measured structural errors, and better preservation of disease-discriminative information. They support reduced, rather than eliminated, structural inconsistencies. External validation, uncertainty estimation, and expert oversight remain necessary before clinical deployment.

Issue S4. Robustness to target-mask quality (Q1)

Target-domain masks are used only during training and are not required at inference. We automatically extract vessel and FAZ masks from OCTA training images using fixed thresholding and morphological post-processing, without official annotations. These masks achieve vessel and FAZ Dice scores of 81.65±3.1081.65\pm3.10 and 80.34±13.3080.34\pm13.30, respectively.

We retrain the full framework from scratch using official or automatically generated masks, with all other settings fixed. As shown in Table 2, performance remains nearly unchanged across the whole image, vessel, and FAZ regions. Thus, on OCT-to-OCTA, the method is robust to moderately noisy automatic masks, although performance may degrade when major anatomical structures are not captured.

Table 2. Robustness to automatic target masks. Masks are extracted from OCTA training images by thresholding and morphology without official annotations. Quality is mean ±\pm SD against annotations. W/V/F denote whole image/vessel/FAZ.

Training mask Vessel Dice \quadFAZ Dice$\quad$ W PSNR W SSIM V PSNR V SSIM F PSNR F SSIM
Official 100.00100.00 100.00100.00 19.0519.05 64.6564.65 18.9318.93 75.7275.72 20.4820.48 35.0535.05
Automatic 81.65±3.1081.65\pm3.10 80.34±13.3080.34\pm13.30 19.0319.03 64.3964.39 18.9518.95 75.3475.34 20.4220.42 35.1935.19

Issue S5. Memory-bank retrieval errors and failure cases (Q4)

Please refer to Reviewer 6DVC, Issue D3 for the full post-hoc subject-versus-prototype and failure-case analysis. Briefly, we compare each output with both its subject-specific annotation and the retrieved training prototypes, including the lowest-confidence retrieval cases.

All 50 outputs have positive Subject Margins and remain globally closer to their own annotations than to the retrieved prototypes, providing no evidence of wholesale replacement of subject-specific anatomy. However, subtle local retrieval-induced errors, including hallucination and omission, cannot be excluded.

Issue S6. Cross-site, cross-scanner, and protocol-shift generalization (W3, Q5, L1)

Please refer to Reviewer Xoww, Issue X1 for the full center-held-out evaluation. All evaluated methods are trained using only SynthRAD2023 centers A and B and tested without adaptation on the unseen center C, with no image, annotation, or memory-bank prototype from center C used during training or model selection.

Our method achieves the best performance across the whole image, soft tissue, and bone regions. Nevertheless, one held-out center cannot cover all scanner, protocol, vendor, or population variations, and broader multi-institutional validation remains necessary.

Issue S7. Inference cost, memory footprint, and sampling time (Q6)

As shown in Table 3, our five-step model uses 81.481.4M inference-time parameters and 0.70 GB0.70\,\mathrm{GB} peak memory, including structural-condition extraction and conditional-flow sampling. It requires five NFE and runs in 0.138 s0.138\,\mathrm{s} for OCT$\rightarrow$OCTA and 0.139 s0.139\,\mathrm{s} for MR$\rightarrow$CT.

Although larger and slower than the one-step Pix2pix, it is faster than SynDiff and the task-specific iterative paired baselines MuTri and DDBM, while achieving better translation quality.

Table 3. Inference efficiency. RTX A6000, batch 1, fp32. Runtime: median CUDA-synchronized after warm-up; memory: peak GPU.

Task Method Params (M) ↓ NFE ↓ Time (s) ↓ Memory (GB) ↓
OCT→OCTA Pix2pix 54.454.4 11 0.0020.002 0.230.23
SynDiff 47.647.6 44 0.2070.207 0.750.75
MuTri 23.023.0 490490 75.01475.014 3.163.16
Ours 81.481.4 55 0.1380.138 0.700.70
MR→CT Pix2pix 54.454.4 11 0.0020.002 0.230.23
SynDiff 47.647.6 44 0.2070.207 0.750.75
DDBM 43.043.0 5050 0.3120.312 0.250.25
Ours 81.481.4 55 0.1390.139 0.700.70

Issue S8. Relationship to degradation-aware Schrödinger bridge methods (W6, Q7)

We thank the reviewer for pointing out this relevant work. DDSB [2] formulates unpaired image restoration as a Schrödinger bridge from degraded to clean images, incorporating degradation-aware optimal transport and dynamic transport consistency.

Our method instead addresses cross-modality translation, where the source is not assumed to be a degraded target image. It anchors a shared structure space using target-domain masks, provides soft supervision through a structural memory bank, and freezes the structure encoder before learning target-domain appearance generation. Thus, the main novelty is anatomical anchoring and the two-stage separation of structure preservation from appearance generation; conditional flow is the generation mechanism rather than the sole novelty. We will add DDSB to the related-work discussion.

Issue S9. Volumetric consistency (L3)

We thank the reviewer for highlighting this limitation. Our current evaluation uses 2D en-face OCT/OCTA projections and independently translated axial MR/CT slices; therefore, the framework does not explicitly enforce inter-slice consistency or guarantee 3D anatomical topology preservation.

We will limit our claims to anatomical preservation within 2D projections and slices. Extending the framework with volumetric models or explicit inter-slice and 3D structural constraints is an important direction for future work.

References

[1] TotalSegmentator: Robust Segmentation of 104 Anatomic Structures in CT Images. Radiology: AI, 2023.

[2] Degradation-Aware Dynamic Schrödinger Bridge for Unpaired Image Restoration. NeurIPS 2025.

Authors · CommentOpenReview ↗

Update to Issue S2: Multi-seed MR-to-CT results

Since posting our initial response, we have completed the three-seed evaluation for MR-to-CT. This update supersedes our earlier statement that multi-seed evaluation was restricted to OCT-to-OCTA.

We repeat the full MR-to-CT pipeline with three independent seeds. For each run, slice-level metrics are first averaged within each of the 20 held-out patients and then averaged across patients. The table below reports the mean and standard deviation across the three patient-averaged results. The consistently small seed-level standard deviations further support the reproducibility of our method on the brain dataset.

Additional Table S2-A. Multi-seed MR-to-CT results. Slice-level metrics are first averaged within each of the 20 held-out patients for each run and reported as mean ±\pm seed SD over three runs.

Region PSNR (dB), Mean ±\pm Seed SD SSIM (%), Mean ±\pm Seed SD
Whole image 28.78±0.0628.78\pm0.06 96.89±0.0596.89\pm0.05
Soft tissue 28.13±0.1628.13\pm0.16 69.08±0.0469.08\pm0.04
Bone 17.75±0.0617.75\pm0.06 80.72±0.1580.72\pm0.15

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Missing a submission?

Loading the discussion…