MedVIGOR: Visual Evidence Internalization for Observation-Driven Reasoning in Medical VLMs
Yuan Wu, Jiayu Qian, Sipeng Wu, Songpan Gao, Ruiming Ye, Zongxian Yang, JinYue Li, Qiankun Li, Yang Liu
NeurIPS 2026
TL;DR. We make medical VLMs reason from the image rather than from clinical text priors by internalizing spatial and semantic visual evidence into the hidden states of every reasoning step.
Abstract. Medical image interpretation requires diagnoses grounded in case-specific visual evidence. However, medical vision-language models often produce plausible answers by exploiting clinical language priors and report-level co-occurrence patterns rather than faithfully using the input image, leading to Visual De-anchoring and Spatial-Semantic Binding Breakdown, where reasoning detaches from visual evidence or binds correct answers to incorrect anatomical support. In this work, we introduce MedVIGOR, a framework that internalizes visual evidence as an intrinsic constraint on medical VLM reasoning. MedVIGOR combines visual-necessity supervision, dual-pathway visual anchor internalization with MedSAM-derived spatial support and DINOv2-derived semantic patterns, and evidence-consistent reinforcement learning to preserve alignment among visual evidence, intermediate reasoning, and final answers. We further present MedVIGOR-Bench, a unified benchmark for evaluating whether medical VLMs are both diagnostically correct and evidentially grounded across concept recognition and visual localization tasks. Experiments show that MedVIGOR improves diagnostic accuracy and grounding fidelity over strong medical VLM baselines, highlighting the value of internalized visual evidence for trustworthy medical reasoning.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:47 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
The paper proposes MedVIGOR, a training framework for medical VLMs that aims to make reasoning grounded in case-specific visual evidence rather than clinical language priors, targeting two named failure modes including visual de-anchoring and spatial-semantic binding breakdown. All reviewers agree the problem is important and clinically well-motivated, that the distinction between answer correctness and evidential correctness is useful, and that the perturbation and anchor-intervention analyses are a genuinely insightful probe of evidence selectivity. However, reviewers raise weaknesses including transfer results on external, verifiably disjoint VQA/grounding benchmarks, an explicit deduplication/leakage analysis between training data and MedVIGOR-Bench with held-out gap-to-baseline numbers and matched-data controlled ablations that isolate the anchor-internalization mechanism from the data-pipeline supervision.
Overall, the initial scores place the paper below the acceptance bar. Please clarify the reviewer's concerns during rebuttal.
Final justification
The paper propose MedVIGOR for observation-driven reasoning in medical VLMs. All reviewers participated in discussion. From the final justification, while several concerns remains unresolved, reviewers are generally satisfyed by the post-rebuttal result. I recommend acceptance and the authors should incorporate the post-rebuttal results in the final revision.
Read meta-review
Meta-review
The paper proposes MedVIGOR, a training framework for medical VLMs that aims to make reasoning grounded in case-specific visual evidence rather than clinical language priors, targeting two named failure modes including visual de-anchoring and spatial-semantic binding breakdown. All reviewers agree the problem is important and clinically well-motivated, that the distinction between answer correctness and evidential correctness is useful, and that the perturbation and anchor-intervention analyses are a genuinely insightful probe of evidence selectivity. However, reviewers raise weaknesses including transfer results on external, verifiably disjoint VQA/grounding benchmarks, an explicit deduplication/leakage analysis between training data and MedVIGOR-Bench with held-out gap-to-baseline numbers and matched-data controlled ablations that isolate the anchor-internalization mechanism from the data-pipeline supervision.
Overall, the initial scores place the paper below the acceptance bar. Please clarify the reviewer's concerns during rebuttal.
Final justification
The paper propose MedVIGOR for observation-driven reasoning in medical VLMs. All reviewers participated in discussion. From the final justification, while several concerns remains unresolved, reviewers are generally satisfyed by the post-rebuttal result. I recommend acceptance and the authors should incorporate the post-rebuttal results in the final revision.
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 2/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper proposes MedVIGOR, a training framework that aims to make medical VLMs ground their reasoning in case-specific visual evidence rather than language priors. It targets two failure modes through three components: a visual-necessity supervision pipeline that filters ~88K reasoning traces requiring image evidence, dual-pathway anchor tokens whose hidden states are supervised to decode MedSAM masks and DINOv2 features, and a GRPO-based RL stage with rewards for protocol, accuracy, visual consistency, and reasoning-evidence alignment. The authors also release MedVIGOR-Bench, a 13K-question benchmark covering modality, disease, anatomy, and visual grounding tasks, and report large gains over strong baselines along with causal interventions showing that perturbing anchor states substantially degrades grounding.
Strengths and weaknesses
Strengths:
- The framing of two failure modes is clear and clinically meaningful. The distinction between answer correctness and evidential correctness is well motivated and not trivially captured by existing medical VQA evaluations.
- The idea of internalizing spatial and semantic evidence into the hidden states of dedicated anchor tokens, rather than feeding visual evidence only at the input or fact-checking after generation, is a thoughtful design choice that targets a real gap in prior work.
- The visual perturbation analysis is a sensible probe of evidence selectivity, and MedVIGOR shows a noticeably larger drop on target-region masking than non-target masking, which is what one would hope for.
Weaknesses:
- The empirical methods rest on a single 7B backbone with LoRA fine-tuning. There are no scaling experiments and no comparison against the same backbone trained with simpler alternatives (for example, standard SFT on the same 88K traces without anchor supervision, or RL without the visual rewards but with the same data). It is therefore hard to disentangle gains attributable to the proposed mechanism from gains attributable to large-scale curated supervision on the same data distribution.
- MedVIGOR-Bench is constructed from UniBiomed, the same corpus used to build the training supervision. The paper does not clearly describe the procedure used to prevent image-level or patient-level leakage between training and evaluation splits, nor does it report deduplication statistics. This is a serious concern given the magnitude of the reported gains (around 20–40 points on grounding-sensitive tasks).
- On external benchmarks (SLAKE, DrVD-Bench) MedVIGOR is competitive with the Qwen2.5-VL backbone but does not dominate strong medical specialist models. This pattern is consistent with the possibility that part of the headline gains reflects benchmark fit rather than general grounding ability.
- The reasoning-evidence alignment reward depends on a "lightweight text-side parser" that maps each sentence to a three-axis descriptor and an importance weight, but the parser is described only at a very high level. Its accuracy directly determines the meaning of this reward signal, and a parsing error analysis or a comparison against human-annotated descriptors is missing.
Questions
-
How are train/test splits constructed within UniBiomed to prevent image-level, patient-level, or near-duplicate leakage into MedVIGOR-Bench? Could you report the exact deduplication procedure and the residual overlap statistics? On a held-out subset that is verifiably disjoint from training, what is the gap to baselines?
-
Could you provide a matched-data ablation in which the Qwen2.5-VL-7B backbone is trained with standard SFT on the same 88K traces (no anchor tokens, no dual-pathway losses) and separately with GRPO using only ?
-
The sentence-level descriptors and importance weights in depend on a text-side parser whose design is not detailed. What model or rules produce these descriptors, what is its accuracy against human annotation on a sample, and how sensitive is the final performance to parser quality?
-
Several recent works pursue very similar goals (grounded medical reasoning with spatial-semantic rewards, RL-based "thinking with grounding," or injecting MedSAM-style spatial evidence into the VLM hidden stream), but none are cited or discussed in the submission. Could the authors clarify MedVIGOR's distinct contribution relative to the following, ideally with direct empirical comparison where feasible? such as [1] Xu, Huihui, et al. "Medground-r1: Advancing medical image grounding via spatial-semantic rewarded group relative policy optimization." International Conference on Medical Image Computing and Computer-Assisted Intervention. Cham: Springer Nature Switzerland, 2025. [2] Liu, Bo, et al. "Gemex-thinkvg: Towards thinking with visual grounding in medical vqa via reinforcement learning." arXiv e-prints (2025): arXiv-2506. [3] Xing, Yang, et al. "MedVL-SAM2: A unified 3D medical vision-language model for multimodal reasoning and prompt-driven segmentation." arXiv preprint arXiv:2601.09879 (2026).
Limitations
Yes
Final justification
Final Justification (Score: 4)
Resolved:
- Cross-split audit (image hash, mask IoU, source-record, question embedding, zero overlap) adequately addresses the leakage concern.
- Matched SFT + basic GRPO ablation shows anchor internalization adds +5.0 Overall / +11.4 VG under identical data, giving credible evidence the mechanism contributes beyond data curation.
- Parser design, human validation (F1 0.87–0.92), and distinction from MedGround-R1 / GEMeX-ThinkVG / MedVL-SAM2 are satisfactory.
Unresolved:
- Curated 88K supervision alone accounts for +24.5 Overall / +21.5 VG, so data curation remains the dominant driver of headline gains.
- External benchmark gains of 3–6 points are much smaller than the ~34 point in-house gap, suggesting residual benchmark-fit effects.
- The leakage audit is author-reported and the benchmark shares corpus with training, so full independence is not established.
Weighting: The mechanism is genuinely novel and the ablation is now clean, which supports lean-accept. The data-vs-mechanism attribution and in-domain benchmark concern prevent moving higher. Borderline accept remains the right call.
Formatting concerns
No
4 comments
We thank the reviewer for recognizing the clinical motivation, hidden-state anchor design, and evidence-selectivity analysis. We provide targeted evidence on split independence, mechanism attribution, external transfer, parser validity, and related work.
W2 / Q1: Split construction, deduplication, and benchmark independence
Concern. The train/test construction, residual overlap, and baseline gap on a verifiably disjoint set require clarification.
Authors' Response
-
1. Split construction.
- For each of the 60 UniBiomed sources,
train.jsonis used only for training construction andtest.jsononly for benchmark construction. - The 87,791 Stage-I traces and 90,000 Stage-II samples come from the source-training side; all 13,000 benchmark questions come from the source-test side and are generated after partitioning.
- UniBiomed does not expose a uniform patient identifier. We retain source-record identity and derive source-specific case/volume prefixes where recoverable for case-level auditing.
- For each of the 60 UniBiomed sources,
-
2. Deduplication and residual overlap.
- We audit every training record against all 13,000 benchmark questions.
- Image: resolved paths and SHA-256 hashes of canonicalized pixels; pHash (Hamming distance <=6) and DINOv2 cosine similarity >=0.98 for near-duplicate retrieval, followed by manual verification.
- Mask: canonical binary-mask hashes and image-conditioned mask IoU >=0.95.
- Case/source: source-record identifiers and filename-derived case/volume prefixes.
- Question/template: normalized exact matching and embedding cosine similarity >=0.95, followed by case/evidence-linkage verification.
- The audit finds 0 exact image or mask overlaps, 0 confirmed near-duplicate images, 0 cross-split source-record or recoverable case/volume-prefix matches, and 0 question candidates linked to the same source record, case/volume, or visual evidence.
- No benchmark question is linked to the same training image, mask, source record, recoverable case/volume, or visual evidence.
-
3. Full audited benchmark and baseline gap.
- All 13,000 questions come from the source-test pool and pass the cross-split audit; no secondary subset is needed and no benchmark item is removed.
- Frozen models are evaluated under the unchanged Table-1 protocol.
| Method | Overall | VG |
|---|---|---|
| Qwen2.5-VL-7B | 53.3 | 53.1 |
| GPT-5 | 66.4 | 74.6 |
| MedVIGOR | 87.5 | 89.2 |
- Result. MedVIGOR exceeds its matched backbone by +34.24 Overall / +36.08 VG and the strongest Table-1 baseline, GPT-5, by +21.10 / +14.57. We will release the audit code and per-source statistics.
W1 / Q2: Matched-data SFT and basic-GRPO controls
Concern. Matched SFT and basic GRPO controls are needed to separate the effects of the 88K traces, anchor internalization, and evidence-consistent rewards.
Authors' Response
- Controlled setup.
- The requested Matched SFT on 88K is VNS Only in Table 3: it uses the same 87,791 traces and Stage-I configuration, but has no anchor tokens, anchor modules, or spatial/semantic losses.
- Matched SFT + basic GRPO starts from this no-anchor checkpoint and matches the 90,000 Stage-II prompts, rollouts, steps, optimizer, and GRPO settings; its only rewards are .
- Following the requested no-anchor setting, the anchor-usage component of is disabled, while its protocol/format component and remain unchanged.
| Setting | Anchors/dual losses | GRPO rewards | Overall | VG |
|---|---|---|---|---|
| Qwen2.5-VL-7B | No | None | 53.3 | 53.1 |
| Matched SFT on 88K (VNS Only) | No | None | 77.8 | 74.6 |
| Matched SFT + basic GRPO | No | 80.3 | 76.9 | |
| Stage-I Full | Yes | None | 82.8 | 86.0 |
| Full MedVIGOR | Yes | All rewards | 87.5 | 89.2 |
- Controlled decomposition.
- Matched SFT: +24.5 Overall / +21.5 VG over the backbone.
- Basic GRPO without anchors: +2.5 / +2.3 over matched SFT, but still 9.1 VG points below Stage-I Full and 12.3 below full MedVIGOR.
- Anchor internalization: under identical SFT data, Stage-I Full adds +5.0 / +11.4 over VNS Only.
- Interpretation. Holding the backbone fixed makes these differences attributable to the training mechanism rather than model scale: curated supervision supplies task adaptation, while anchor internalization and evidence-consistent rewards supply the grounding-sensitive gains.
Thanks for the detailed rebuttal. The cross‑split audit and the matched‑SFT / basic‑GRPO decomposition address my main concerns, and anchor internalization adds a meaningful +11.4 VG on top of curated supervision. The more modest 3–6‑point gains on the five public benchmarks are consistent with the mechanism claim, while also moderating the headline numbers reported on internal data. My concerns have been addressed, and I will keep my score at 4.
We sincerely thank the reviewer for the careful reassessment and for confirming that the cross-split audit and matched-data controls address the main concerns. We especially appreciate your recognition that anchor internalization contributes a meaningful +11.4 VG beyond curated supervision.
Although you have indicated that your main concerns are addressed, we would like to provide additional evidence concerning the single-backbone limitation raised in your original review. These experiments were still running when we submitted our initial rebuttal, and both the Stage-I and Stage-II evaluations on Qwen3-VL-8B are now complete.
For Qwen3-VL-8B, we use the same 87,791 VNS traces in Stage I and the same 90,000 RL samples in Stage II, while retaining the Qwen2.5-VL-7B training configuration for each stage. Thus, the data split, optimization settings, stage-specific objectives and rewards, and evaluation procedure are matched across backbones. The following comparison separates the incremental contributions of anchor internalization and evidence-consistent RL.
| Backbone | Setting | Overall | VG | Increment (Overall/VG) |
|---|---|---|---|---|
| Qwen2.5-VL-7B | VNS Only | 77.8 | 74.6 | - |
| Qwen2.5-VL-7B | Stage-I Full | 82.8 | 86.0 | +5.0 / +11.4 |
| Qwen2.5-VL-7B | Full MedVIGOR | 87.5 | 89.2 | +4.7 / +3.2 |
| Qwen3-VL-8B | VNS Only | 78.6 | 77.2 | - |
| Qwen3-VL-8B | Stage-I Full | 83.1 | 87.5 | +4.5 / +10.3 |
| Qwen3-VL-8B | Full MedVIGOR | 88.4 | 90.7 | +5.3 / +3.2 |
Across both backbones, the transition from VNS Only to Stage-I Full yields a substantially larger gain on VG than on Overall, consistently isolating the grounding contribution of anchor internalization. On Qwen3-VL-8B, Stage-II evidence-consistent RL further contributes +5.3 Overall / +3.2 VG, closely matching the corresponding +4.7/+3.2 gain on Qwen2.5-VL-7B. Together, these results show that both anchor internalization and evidence-consistent optimization transfer beyond the original backbone.
The Qwen3-VL-8B result establishes transfer across backbone generations; in future work, we will further evaluate MedVIGOR on architecturally distinct backbones, including the InternVL and LLaVA families, to examine generality across different visual encoders, multimodal projectors, and language-model families.
We deeply appreciate the constructive feedback. It directly prompted us to add the cross-split audit, sharpen the matched-data attribution, and complete the Qwen3-VL-8B cross-backbone validation. These additions make the paper more rigorous and help readers distinguish the contributions of curated supervision, anchor internalization, and evidence-consistent RL. We will incorporate these clarifications and results into the revision. We would be grateful if you could consider this additional evidence in your final assessment.
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 2/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper proposes MedVIGOR, a framework for improving grounded reasoning in medical VLMs by addressing visual de-anchoring and spatial-semantic binding breakdown. It uses visual-necessity supervision, MedSAM/DINOv2-supervised anchor tokens, and evidence-consistent RL to better align answers, reasoning, and visual evidence. The paper also introduces MedVIGOR-Bench and reports strong results with supporting ablations, perturbation analysis, and anchor-state interventions.
Strengths and weaknesses
** Strengths**
- The paper addresses an important problem with clear clinical relevance. The distinction between visual de-anchoring and spatial-semantic binding breakdown is clear and useful for analyzing grounding failures in medical VLMs.
- The visual anchor internalization mechanism is technically clear.
- The perturbation analysis and anchor-state interventions are helpful. In particular, Figure 5 supports the motivation to reduce visual de-anchoring.
** Weaknesses**
- The main performance gains are concentrated on MedVIGOR-Bench, while the improvements on SLAKE and DrVD-Bench are relatively limited. This makes the evidence for generalization less convincing.
- The specific contribution of visual anchor internalization is not fully isolated. The ablation results suggest that a large portion of the improvement comes from visual-necessity supervision, and multi-view supervision appears closer to data enrichment than a fundamentally new reasoning mechanism.
- It remains unclear whether anchor tokens are substantially more effective than simpler alternatives, such as mask/DINO auxiliary supervision without anchor tokens, ordinary visual prefix tokens, or capacity-matched random latent tokens.
Questions
- Additional clarification on the independence between the training data and MedVIGOR-Bench would be helpful, such as deduplication analyses at the image, mask, case-source, and question-template levels.
- Adding more public and grounding-sensitive comprehensive benchmarks would help validate the generalization of the method, especially given the large gains on MedVIGOR-Bench but smaller improvements on SLAKE and DrVD-Bench.
- More rigorous controlled baselines would help isolate the effect of visual anchor internalization, such as mask/DINO auxiliary supervision without anchor tokens, ordinary visual prefix tokens, capacity-matched random latent tokens, and MedSAM-only or DINO-only anchor variants.
Limitations
yes
Final justification
This work is well motivated, with a complete methodological chain and experimental design, and the rebuttal has resolved most of my concerns. While substantial gains are observed on the self‑constructed training data and benchmark, the improvements on external benchmarks, though positive, do not yet fully establish the model’s generalizable reasoning ability.
Formatting concerns
No
4 comments
W2-W3 / Q3: Anchor contribution and controlled alternatives
Concern. The gain may primarily come from VNS, multi-view enrichment, auxiliary MedSAM/DINO losses, token placement, or added capacity rather than anchor internalization.
Authors' Response
-
1. Contribution attribution.
- Table 3 provides a staged decomposition.
- VNS: Qwen2.5-VL-7B to VNS Only adds +24.5 Overall / +21.5 VG, the largest task-adaptation gain.
- Anchor internalization: with the same 87,791 VNS traces, Stage-I Full adds +5.0 / +11.4, with a larger contribution to grounding.
- Evidence-consistent RL: Stage II adds a further +4.7 / +3.2.
- Multi-view supervision serves as data enrichment within VNS. The mechanism contribution lies in internalizing spatial-semantic evidence into reasoning states and preserving this coupling during generation.
-
2. Controlled alternatives.
- We isolate the alternatives at Stage I, before RL, because Stage-II visual/alignment rewards are defined on anchor states.
- All variants use the same Qwen2.5-VL-7B initialization, 87,791 VNS traces, optimizer, LoRA configuration, epochs, batch size, training-token budget, and evaluation protocol.
- VNS Only: no anchors or spatial/semantic losses.
- Auxiliary w/o anchors: the same MedSAM/DINO losses are applied to pooled native image-token states without inserting anchor positions.
- Ordinary visual prefix: the same number of MedSAM/DINO-supervised tokens is placed before the question rather than inside the reasoning stream.
- Capacity-matched latents: the same number, dimensions, and positions as anchors, but optimized only with the language-modeling objective.
- Stage-I Full: MedSAM/DINO-supervised anchors are inserted inside
<perceive>with both internalization losses. - The visual-prefix, capacity-matched-latent, and Stage-I Full variants use the same number and dimensionality of added tokens. Auxiliary w/o anchors uses an equal number of pooled native image-token readout states, while VNS Only remains the anchor-free baseline.
| Stage-I condition | Overall | VG | SSB | BER (lower is better) |
|---|---|---|---|---|
| VNS Only | 77.8 | 74.6 | 53.8 | 28.3 |
| Auxiliary w/o anchors | 79.2 | 78.7 | 58.5 | 24.8 |
| Ordinary visual prefix | 80.3 | 81.9 | 62.4 | 21.6 |
| Capacity-matched latents | 78.4 | 76.0 | 55.1 | 27.7 |
| Stage-I Full | 82.8 | 86.0 | 67.1 | 17.4 |
- Evaluation scope. SSB/BER are computed on the 3,506 Disease and Abnormality samples with paired answer-grounding labels, following Sec. 5.3.
- 3. Results.
- Relative to Auxiliary w/o anchors, Stage-I Full improves Overall/VG/SSB by 3.6/7.3/8.6 points and lowers BER by 7.4.
- Relative to the strongest alternative, Ordinary visual prefix, it improves Overall/VG/SSB by 2.5/4.1/4.7 and lowers BER by 4.2.
- Relative to Capacity-matched latents, it improves Overall/VG/SSB by 4.4/10.0/12.0 and lowers BER by 10.3.
- The submitted Spatial Only (80.8/84.3 Overall/VG) and Semantic Only (80.1/84.0) ablations additionally establish the complementarity of the two anchor pathways.
- Table 2 provides functional evidence from the full MedVIGOR checkpoint: noise-corrupting trained anchor states reduces SSB from 72.5 to 22.9 and raises BER from 16.6 to 65.5 while parameters and non-anchor states remain fixed.
- Takeaway. VNS supplies the main visual-necessity and task-adaptation signal. On the same data, dual-pathway anchor internalization adds evidence retention and spatial-semantic binding beyond auxiliary supervision, prefix placement, and added capacity; evidence-consistent RL then preserves this coupling during generation.
We thank the reviewer for the careful assessment and for recognizing the clinical relevance, technical clarity of visual-anchor internalization, and value of the perturbation and anchor-state intervention analyses. We provide additional evidence on training-benchmark independence, cross-distribution generalization, and the distinct contributions of VNS, multi-view data construction, and anchor internalization.
Q1: Training-benchmark independence
Concern. Because the training supervision and benchmark are both derived from UniBiomed, image-, annotation-, case-, and template-level leakage must be excluded.
Authors' Response
-
1. Construction.
- We do not randomly divide a single merged pool.
- For each UniBiomed source, its provided
train.jsonis used only for training-data construction, while itstest.jsonis merged separately for benchmark construction. - MedVIGOR-Bench is sampled only from this source-test pool, and questions are generated after this assignment.
-
2. Cross-split audit.
- We audit every record in the 87,791-trace Stage-I set and 90,000-sample Stage-II set against all 13,000 benchmark questions.
- Image: resolved paths and SHA-256 hashes of canonicalized pixels; near-duplicate retrieval using pHash (Hamming distance <=6) and DINOv2 cosine similarity >=0.98, followed by manual verification.
- Mask/annotation: canonical binary-mask hashes and image-conditioned mask IoU >=0.95.
- Case/source: source-record identifiers and, where recoverable, filename-derived case/volume prefixes.
- Question/template: normalized exact matching and embedding cosine similarity >=0.95, followed by case/evidence-linkage verification.
| Audit level | Result on all 13,000 benchmark questions |
|---|---|
| Image | 0 exact or confirmed near-duplicate pairs |
| Mask/annotation | 0 exact or image-conditioned near-duplicate pairs |
| Case/source | 0 source-record or recoverable case/volume-prefix matches |
| Question/template | 0 case- or evidence-linked cross-split duplicates |
- Patient/case identifiers.
- UniBiomed does not expose a uniform patient identifier. We therefore use source-record identifiers and, where recoverable, filename-derived case/volume prefixes for the case/source audit.
- Question candidates are verified against their associated source records and visual evidence.
- Takeaway. No overlap is detected under these cross-split criteria, so the complete 13,000-question benchmark is retained and Table 1 is unchanged. MedVIGOR improves over Qwen2.5-VL-7B by 34.24 points Overall (53.30 to 87.54) and 36.08 points on VG (53.12 to 89.20). We will release the audit script, thresholds, and per-source statistics.
W1 / Q2: Generalization beyond MedVIGOR-Bench
Concern. The large MedVIGOR-Bench improvement and smaller SLAKE/DrVD-Bench gains may indicate limited cross-distribution generalization.
Authors' Response
- Evaluation protocol.
- We add VQA-RAD, PathVQA, and PMC-VQA to the original SLAKE and DrVD-Bench evaluation.
- Both models are evaluated without external-benchmark fine-tuning, using identical prompts, decoding, answer extraction, test splits, and official metrics.
- No external validation or test set is used for training or model selection.
| Benchmark | Focus | Qwen2.5-VL-7B | MedVIGOR | Change |
|---|---|---|---|---|
| SLAKE | Medical VQA | 61.7 | 67.4 | +5.7 |
| DrVD-Bench | Visual evidence and clinical reasoning | 53.1 | 56.1 | +3.0 |
| VQA-RAD | Clinician-curated radiology VQA | 62.2 | 64.5 | +2.3 |
| PathVQA | Pathology VQA | 40.9 | 44.1 | +3.2 |
| PMC-VQA | Large-scale multimodal medical VQA | 51.9 | 54.6 | +2.7 |
- Result.
- MedVIGOR improves its matched backbone on all five external benchmarks (+2.3 to +5.7), including three newly added and independently constructed distributions.
- VQA-RAD, PathVQA, and PMC-VQA establish cross-distribution answer transfer, while DrVD-Bench provides complementary evidence-sensitive evaluation.
- These results show that the improvement is not confined to MedVIGOR-Bench.
Thank you for the detailed rebuttal. This rebuttal addresses most of my main concerns, so I will raise my score to 4.
We sincerely thank the reviewer for carefully reconsidering our work and updating your assessment. We are genuinely grateful for the time and attention you devoted to our submission.
Your feedback directly prompted us to conduct a more comprehensive cross-split audit, broaden the external evaluation, and add rigorous controlled alternatives that clarify the respective contributions of VNS, anchor internalization, and evidence-consistent RL. These additions have materially improved the rigor, transparency, and clarity of the paper, and will also help readers better understand the scope of our claims.
We will incorporate all of these clarifications and results into the revision. Thank you again for your thoughtful and constructive feedback.
- Rating
- 3/6
- Confidence
- 3/5
- Quality
- 2/4
- Clarity
- 3/4
- Significance
- 2/4
- Originality
- 2/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper targets two failure modes in medical VLMs: models answering from clinical language priors rather than the image ("Visual De-anchoring"), and models giving the right answer while attending to the wrong region ("Spatial-Semantic Binding Breakdown"). The proposed framework, MedVIGOR, has three parts: (1) a data pipeline built on UniBiomed (27M image-text-annotation triplets) that constructs 931,576 VQA pairs designed to be answerable only from the image, then synthesizes reasoning traces under multi-view conditioning in direct/short/long styles, all generated with Qwen3.5-122B; (2) special anchor tokens whose hidden states are supervised to decode into MedSAM masks and DINOv2 features; and (3) RL stage with GRPO with stabilization, visual-consistency, and reasoning-evidence alignment rewards. The authors also introduce MedVIGOR-Bench, composed of 13,000 questions across modality recognition, disease/abnormality, anatomy ID, visual grounding. The model is Qwen2.5-VL-7B trained on 8×H100. Reported gains are on their in-house benchmark and the paper adds perturbation and anchor-intervention analyses to argue the grounding is causal.
Strengths and weaknesses
Strengths
- The problem is important and well-motivated: medical VLMs that lean on language priors instead of the image or that get the right answer for the wrong visual reasons, are an obstacle to clinical use.
- The perturbation ablation experiments (Fig. 5) with text-only, shuffled-image, target-region-masked and non-target-region-masked settings are insightful and convincingly show that MedVIGOR relies far less on language priors than the baselines.
Weaknesses
- Generalization to other datasets is the main weakness of this paper. On SLAKE and DrVD-Bench (Fig. 3), MedVIGOR underperform most of the models shown. This undercuts the main results in Table 1, which are not a fair comparison as zero-shot baselines are compared against a model heavily trained on the same UniBiomed source and evaluated on a benchmark the authors built themselves. For real impact, the model needs to demonstrate generalization. The MedEvalKit suite, open-sourced by the Lingshu authors, offers many external VQA benchmarks to test this.
- The gains come mostly from the data pipeline contribution. In Table 3a, VNS Only (supervision alone, no anchors, no RL) moves Qwen2.5-VL with +24.5 pts, while both anchor pathways and the entire Stage II RL together add only ~10 more points.
- Limited to 2D, despite a CT/MRI-heavy dataset. The Qwen2.5-VL-7B backbone processes single slices, even though the supervision is dominated by inherently volumetric CT and MRI.
- The MedVIGOR-Bench tasks are mostly simple anatomy/region questions (e.g. single-organ ID, box selection) that are far from the cases real practitioners need.
- Missing comparison to ReXGrounding-CT, a recent relevant existing CT-grounding benchmark, which would directly test the transfer claim.
- No broader impact section
- Minor points
- VNS acronym is not defined
- for easier reading, the evaluation m
Questions
- Can you report transfer results for MedVIGOR on further external VQA benchmarks, e.g. those in MedEvalKit? The current SLAKE/DrVD-Bench results suggest the model may be overfit to the constructed distribution.
- In Table 3, does the Qwen2.5-VL row correspond to the zero-shot model? If so, do you have a controlled experiments with the same backbone fine-tuned on "answer-direct" data, to isolate the contribution of the VNS data?
Limitations
Discussed in Appendix G, where the authors ackowledge the 7B backbone, single-image scope, and reliance on external visual supervision. Yet, the slice-based handling of volumetric CT/MRI is also not acknowledged as a constraint. There is no broader impact section despite the checklist marking it Yes, and no statistical significance / error bars anywhere.
Final justification
As it stands, the mechanism is well-isolated and the benchmark is a useful artifact, but the generalization evidence does not yet support broad utility. I am raising my recommendation to 3 to acknowledge that the rebuttal has materially improved the paper, but it remains below the acceptance bar for this reason.
Formatting concerns
Ok
7 comments
We thank the reviewer for recognizing the clinical importance of grounding medical answers in image evidence and the value of our target-region perturbation analysis. We provide additional evidence on external transfer, benchmark independence, and the respective contributions of answer supervision, Visual-Necessity Supervision (VNS), anchor internalization, and RL.
W1 / Q1: External generalization and benchmark independence
Concern. The current SLAKE/DrVD-Bench results may indicate adaptation to the constructed distribution rather than broader transfer.
Authors' Response
- 1. External transfer.
- We add VQA-RAD, PathVQA, and PMC-VQA, all public benchmarks supported by MedEvalKit, to the reported SLAKE and DrVD-Bench evaluation.
- Qwen2.5-VL-7B and MedVIGOR are evaluated without external-benchmark fine-tuning, using identical prompts, decoding, answer extraction, test splits, and official metrics.
| Benchmark | Evaluation focus | Qwen2.5-VL-7B | MedVIGOR | Change |
|---|---|---|---|---|
| SLAKE | Medical VQA | 61.7 | 67.4 | +5.7 |
| DrVD-Bench | Visual evidence and clinical reasoning | 53.1 | 56.1 | +3.0 |
| VQA-RAD | Clinician-curated radiology VQA | 62.2 | 64.5 | +2.3 |
| PathVQA | Pathology VQA | 40.9 | 44.1 | +3.2 |
| PMC-VQA | Large-scale multimodal medical VQA | 51.9 | 54.6 | +2.7 |
-
External result. MedVIGOR improves its matched backbone on all five external distributions. This controlled comparison shows that the improvement transfers beyond MedVIGOR-Bench.
-
2. Benchmark independence.
- For each of the 60 UniBiomed sources,
train.jsonis used only for training construction andtest.jsononly for benchmark construction; questions are generated after partitioning. - We audit the 87,791 Stage-I traces and 90,000 Stage-II samples against all 13,000 benchmark questions at the image, mask, and case/source levels.
- Normalized question-similarity candidates are jointly verified using their source and visual-evidence linkage. No benchmark question is linked to the same training image, mask, recoverable case/volume, or visual evidence.
- For each of the 60 UniBiomed sources,
-
Takeaway. On the complete audited benchmark, MedVIGOR exceeds Qwen2.5-VL-7B by +34.24 Overall and +36.08 VG, consistent with Table 1. The external results and full-benchmark audit jointly show that the gains are not specific to the constructed distribution.
W2 / Q2: Answer-direct matched-data control
Concern. The improvement may arise from fine-tuning on the constructed image-question-answer pairs rather than from VNS and anchor internalization.
Authors' Response
- Controlled setup.
- The Qwen2.5-VL row in Table 3 is the original zero-shot backbone.
- VNS Only uses the 87,791 visually necessary reasoning traces but no anchor tokens, spatial/semantic internalization losses, or RL.
- We add an answer-direct control using the same image-question-answer instances: the reasoning trajectory is removed and only the final answer is trained. Backbone, LoRA configuration, optimizer, sample exposure, optimizer updates, and evaluation protocol are matched.
| Training condition | Reasoning | Anchors/RL | Overall | VG |
|---|---|---|---|---|
| Qwen2.5-VL-7B zero-shot | No | No | 53.3 | 53.1 |
| Answer-direct SFT on the same 88K examples | No | No | 71.4 | 65.2 |
| VNS Only | Yes | No | 77.8 | 74.6 |
| Stage-I Full | Yes | Anchors | 82.8 | 86.0 |
| Full MedVIGOR | Yes | Anchors + RL | 87.5 | 89.2 |
- Controlled decomposition.
- Ordinary task adaptation: answer-direct SFT adds +18.1 Overall / +12.1 VG over the zero-shot backbone.
- Visually necessary reasoning: VNS adds +6.4 / +9.4 over answer-direct SFT.
- Anchor internalization: with identical VNS data, Stage-I Full adds +5.0 / +11.4 over VNS Only.
- Evidence-consistent RL: Stage II adds a further +4.7 / +3.2.
- Interpretation. Multi-view supervision functions as data enrichment within VNS. The mechanism contribution lies in anchor-state internalization and evidence-consistent optimization: VNS makes the supervision visually necessary, anchors strengthen evidence retention and grounding, and RL preserves evidence-reasoning-answer consistency.
W3-W5: Scope, benchmark role, and ReXGroundingCT
Concern. The current evaluation is 2D, the benchmark may emphasize relatively simple tasks, and ReXGroundingCT is not discussed.
Authors' Response
- W3 - 2D scope.
- CT and MRI are processed as annotated 2D slices under the same single-image protocol for all models.
- MedVIGOR addresses how evidence in the current image is retained in reasoning states. We will explicitly state that multi-slice aggregation and full 3D reasoning are extensions beyond the current evaluation.
- W4 - Benchmark role.
- MedVIGOR-Bench diagnoses visual de-anchoring and spatial-semantic binding through tasks with verifiable answers and evidence labels.
- It includes 4,062 open-ended questions and 3,506 Disease/Abnormality samples with paired answer-grounding labels.
- On the more demanding subsets, MedVIGOR improves open-ended Disease/Abnormality from 16.8 to 79.5, open-ended Anatomy ID from 28.8 to 49.0, and Visual Grounding from 53.1 to 89.2. The benchmark therefore evaluates disease reasoning and evidence binding in addition to organ identification.
- W5 - ReXGroundingCT.
- We will add ReXGroundingCT to the related work.
- It evaluates free-text findings against 3D chest-CT segmentations, whereas MedVIGOR evaluates 2D VQA and candidate-region selection. The protocols measure complementary capabilities, and ReXGroundingCT provides a concrete benchmark for extending anchor internalization to multi-slice and volumetric evidence.
W6 and minor points: Uncertainty and broader impact
Authors' Response
- Statistical uncertainty.
- We define Visual-Necessity Supervision (VNS) at first use and report paired bootstrap 95% confidence intervals separately from the shared performance table.
- The main Overall/VG differences have intervals of [33.2, 35.3] and [34.8, 37.4], respectively; image/evidence-grouped resampling is used when multiple questions share visual evidence.
- Broader impact.
- We will add an explicit Broader Impact section. MedVIGOR is a research model rather than a diagnostic device.
- Plausible but incorrectly localized reasoning can create false confidence; deployment therefore requires external clinical validation, clinician oversight, privacy safeguards, and auditing across sites, modalities, and demographic groups.
We sincerely thank the reviewer again for the careful and rigorous assessment. We have taken each of your concerns seriously, and your feedback has prompted us to re-examine both our evaluation and presentation more thoroughly. The additional external benchmarks, matched-data controls, complete cross-split audit, uncertainty analysis, and clearer discussion of the method's scope have substantially strengthened the rigor and transparency of the paper.
Since our initial response, we have also completed a matched cross-backbone evaluation on Qwen3-VL-8B. We use the same 87,791 Stage-I traces, 90,000 Stage-II samples, and stage-specific training configurations as Qwen2.5-VL-7B. All entries below report Overall/VG; parentheses denote the increment over the preceding stage.
| Backbone | VNS Only | Stage-I Full | Full MedVIGOR |
|---|---|---|---|
| Qwen2.5-VL-7B | 77.8 / 74.6 | 82.8 / 86.0 (+5.0 / +11.4) | 87.5 / 89.2 (+4.7 / +3.2) |
| Qwen3-VL-8B | 78.6 / 77.2 | 83.1 / 87.5 (+4.5 / +10.3) | 88.4 / 90.7 (+5.3 / +3.2) |
The closely matched decomposition across both backbones reproduces the grounding-sensitive contribution of anchor internalization and the additional benefit of Stage-II optimization. This complements the public-benchmark results: the external evaluations establish cross-distribution transfer, while the Qwen3-VL-8B experiment provides cross-backbone evidence. We will include these results and clarifications in the revision.
As your feedback has been especially valuable in improving the paper, we would be sincerely grateful for any further guidance you may have. At your convenience, could you please let us know whether any of your concerns would benefit from further clarification or additional evidence? We remain fully available during the remaining discussion period and would be very happy to respond promptly.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
W3: External generalization
Authors' Response
W4 / Q3: Text-side parser for us and gs
Authors' Response
Scope. The parser is deterministic and parameter-free, is used only to compute Ralign during Stage-II training, and is absent at inference.
1. Parser design.
<think>, split it into sentences at sentence-final punctuation, and match entries from three fixed medical-imaging lexicons: spatial location, boundary/structure, and visual semantics.Parser mapping.
2. Human validation.
3. Sensitivity to parser quality.
Q4: Distinction from recent grounded medical reasoning methods
Authors' Response