potentialpaper

PhysFlow: Physics-Intrinsic Velocity Regularization for Motion-Intensive Video Generation

Xianglong Guo, Chang Yu, Haobo Xu, Junhao Ma, Zhen Lei

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

Abstract. Text-to-video models built on flow matching generate compelling videos for common prompts but degrade systematically under motion-intensive scenarios, producing artifacts such as object fragmentation, geometric deformation, and temporal flickering. Existing training-free approaches operate at the attention or guidance-scale level, neither of which directly addresses the velocity field that governs latent motion evolution. We observe that these motion artifacts stem from local misalignment between the predicted velocity and the latent's frame-axis temporal structure, a signal that can be diagnosed from quantities the sampler already computes. Based on this, we propose PhysFlow, a training-free velocity regularization method. PhysFlow constructs a per-frame latent flow residual to locate motion-inconsistent regions, steers the velocity to restore frame-axis alignment, and bounds the correction via residual-aware masking and safe clipping. We also introduce MotionStress-100, a five-category benchmark with a VLM-based protocol that isolates motion-intensive failures. On Wan2.1, PhysFlow improves the average MotionStress score over the baseline with no additional inference cost (1.00×1.00\times cost), outperforming CFG-Zero* (-10.0%, 0.98×0.98\times cost) and FlowMo (+0.7%, 2.12×2.12\times cost) by at least 4.7%, while improving VBench motion smoothness without loss of visual fidelity.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
30 Apr 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:46 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

This paper presents PhysFlow, a training-free method for improving text-to-video generation when the prompt involves fast or complex motion. The main idea is to detect when the model’s predicted motion is inconsistent with the changes between nearby video frames, and then slightly adjust the sampling process in those regions. The method is simple, requires no retraining or extra model calls, and adds almost no inference cost. The ablation results also suggest that the proposed residual signal, rather than ordinary temporal smoothing, is the main source of the improvement.

The main concern, raised by KiC9, 4GJ8, and phYQ, is that the experiments do not yet support the paper’s broad claims. Almost all results are based on Wan2.1. The additional 14B experiment is still within the same model family, and the improvement becomes noticeably smaller. Therefore, the current evidence shows that PhysFlow works on Wan2.1, but not yet that it works generally across flow-based video models. A result on one different backbone, even on a smaller but balanced subset of the benchmark, would be particularly helpful.

The second concern is that the reported improvements are modest and somewhat uneven, as noted by all three reviewers. Much of the gain on MotionStress-100 comes from the fine-grained physics category, while several other categories improve only slightly. In addition, the main evaluation relies on a single vision-language model judging a newly introduced benchmark. The human study is useful, but it contains only 20 video pairs, and important details such as the number of raters and agreement between raters are missing. The rebuttal should therefore provide uncertainty estimates, fuller human-study details, and ideally results using another VLM judge or an analysis of how well the automatic judgments agree with humans.

KiC9 also questions the term “physics-intrinsic”. I view this mainly as an issue of positioning rather than a technical flaw. The method encourages smoother and more consistent motion in latent space, but it does not directly enforce physical laws. The authors should narrow the wording accordingly.

Overall, I do not see a clear correctness problem. A convincing response on cross-model generality and evaluation reliability could significantly improve the assessment; without such evidence, the paper remains borderline because the current experiments are not yet strong enough for the breadth of the claims.

Area Chair mz8H · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

This paper presents PhysFlow, a training-free method for improving text-to-video generation when the prompt involves fast or complex motion. The main idea is to detect when the model’s predicted motion is inconsistent with the changes between nearby video frames, and then slightly adjust the sampling process in those regions. The method is simple, requires no retraining or extra model calls, and adds almost no inference cost. The ablation results also suggest that the proposed residual signal, rather than ordinary temporal smoothing, is the main source of the improvement.

The main concern, raised by KiC9, 4GJ8, and phYQ, is that the experiments do not yet support the paper’s broad claims. Almost all results are based on Wan2.1. The additional 14B experiment is still within the same model family, and the improvement becomes noticeably smaller. Therefore, the current evidence shows that PhysFlow works on Wan2.1, but not yet that it works generally across flow-based video models. A result on one different backbone, even on a smaller but balanced subset of the benchmark, would be particularly helpful.

The second concern is that the reported improvements are modest and somewhat uneven, as noted by all three reviewers. Much of the gain on MotionStress-100 comes from the fine-grained physics category, while several other categories improve only slightly. In addition, the main evaluation relies on a single vision-language model judging a newly introduced benchmark. The human study is useful, but it contains only 20 video pairs, and important details such as the number of raters and agreement between raters are missing. The rebuttal should therefore provide uncertainty estimates, fuller human-study details, and ideally results using another VLM judge or an analysis of how well the automatic judgments agree with humans.

KiC9 also questions the term “physics-intrinsic”. I view this mainly as an issue of positioning rather than a technical flaw. The method encourages smoother and more consistent motion in latent space, but it does not directly enforce physical laws. The authors should narrow the wording accordingly.

Overall, I do not see a clear correctness problem. A convincing response on cross-model generality and evaluation reliability could significantly improve the assessment; without such evidence, the paper remains borderline because the current experiments are not yet strong enough for the breadth of the claims.

Reviewer phYQOpenReview ↗
Rating
4/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The paper proposes PhysFlow, a training-free inference-time correction for flow-matching T2V samplers. It computes a latent flow residual that measures mismatch between predicted velocity and frame-to-frame latent trajectory direction, then applies a masked, clipped velocity correction plus a straightness prior during active sampling steps. The authors also introduce MotionStress-100, a motion-heavy prompt benchmark with VLM yes/no scoring. Experiments on Wan2.1 report modest but consistent gains over baseline and selected inference-time alternatives at roughly unchanged cost.

Strengths and weaknesses

Strengths:

First, the paper identifies a useful and underexplored intervention point for training-free video generation: the sampler velocity field. Most related inference-time methods modify CFG, attention, or optimize latents; PhysFlow instead directly regularizes the velocity predicted by a flow-matching T2V model. This is a clean design choice because the correction acts exactly where the sampler determines temporal transport.

Second, the latent flow residual is a plausible motion-failure diagnostic. It compares the predicted per-frame velocity with the local frame-to-frame latent trajectory direction, so it is naturally connected to artifacts such as object fragmentation, shape deformation, and temporal flickering. The residual-aware mask, safe clipping, and active schedule are also reasonable engineering choices: they let the method act where inconsistency is high while reducing the chance of damaging late-stage visual refinement.

Third, the method is practically attractive. It is training-free, requires no new network, and reports essentially unchanged inference cost. This makes the contribution more useful than a heavier test-time optimization method: even a modest improvement can matter if it is a drop-in switch for existing flow-matching samplers.

Weaknesses:

The main weakness is that the gains are small. The headline MotionStress improvement is around +3.7 absolute points, and the VBench motion-smoothness gain is also modest. This is acceptable for a zero-cost method, but it raises the evidentiary bar: uncertainty estimates, human calibration, and robustness checks become central to interpreting the result.

The method is still only demonstrated within the Wan2.1 model family. The 14B result is useful, but it does not establish cross-family generality. Since the motivation says similar motion artifacts appear in other T2V systems, a result on at least one non-Wan flow-matching backbone is important. This is especially important because the observed gain on Wan is positive but not large.

The dependence on sampling steps is under-quantified. The limitations say PhysFlow may fail under aggressive few-step distillation because the active schedule has too few steps to operate, but modern deployment often uses few-step samplers. A step-count and sampler sweep is needed to clarify the practical operating range.

Another practical weakness is the lack of released mp4 evidence. For a motion-focused T2V paper, static figures and aggregate metrics are not enough: reviewers need the actual videos to inspect temporal flicker, object fragmentation, motion continuity, and prompt adherence over time. The paper would be much easier to evaluate if it provided the generated mp4s for the main qualitative examples, paired-seed baseline comparisons, MotionStress samples, and representative failure cases.

Questions

Can you evaluate PhysFlow on at least one non-Wan flow-matching T2V model, such as CogVideoX or HunyuanVideo? This is the most important missing experiment, because the current improvements are positive but modest and all main evidence is within the Wan2.1 family.

Please report confidence intervals or significance tests for the MotionStress QA scores. Are the approximately +3.7 absolute points robust across prompts and random seeds, or are they driven by a small subset of examples?

Please provide more complete human-study details: number of unique raters, number of judgments per rater, compensation, rater-level aggregation, inter-rater agreement, and confidence intervals for the paired-seed win rates.

Limitations

Adequately addressed. The Limitations paragraph honestly notes failure under heavily-tokenized latents and aggressive few-step distillation (too few steps for the schedule), and that PhysFlow corrects sampler-induced inconsistency, not prompt ambiguity.

Final justification

As the rebuttal response mainly resolved my concerns, I will maintain my score (Borderline Accept).

Formatting concerns

None

3 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We thank the reviewer for the valuable feedback. We are glad that the reviewer appreciates the contribution of our work. Below, we address the reviewer’s concerns one by one.

Q1: Generalization to a Non-Wan Backbone

We thank the reviewer for this insightful question. We evaluate PhysFlow on HunyuanVideo-1.5 and Wan2.2 using the same fixed hyperparameters as for Wan2.1, without backbone-specific tuning.

Backbone Method Linear Human Fluid Camera Fine Physics Avg.
HunyuanVideo-1.5 Baseline 62.22 65.56 91.67 59.44 73.33 70.44
PhysFlow 61.67 68.89 94.17 60.00 76.67 72.28
Wan2.2 (121 frames) Baseline 65.56 51.11 88.33 58.89 59.17 64.61
PhysFlow 71.67 52.78 92.50 63.33 65.00 69.06

PhysFlow improves the average MotionStress score by +1.84 points on HunyuanVideo-1.5 and +4.45 points on Wan2.2. On HunyuanVideo-1.5, four of five categories improve, while Linear Motion decreases marginally by 0.55 points. These results provide direct cross-family evidence that PhysFlow transfers beyond Wan2.1 without model-specific retuning.

Q2: Statistical Robustness of MotionStress Improvements

We thank the reviewer for this valuable feedback. All comparisons are paired by prompt and random seed. We average the three paired-seed generations for each prompt and perform a paired bootstrap over prompt-level differences using 100,000 resamples. The prompt-level confidence intervals are shown below:

MS-100 Category Baseline PhysFlow Δ 95% CI
Linear 65.56 66.11 +0.56 [−6.67, 8.33]
Human / Complex 60.00 63.33 +3.33 [−7.78, 13.33]
Fluid / Particle 93.33 94.17 +0.83 [−5.00, 6.67]
Camera 58.33 58.89 +0.56 [−6.67, 7.22]
Fine-grained Physics 57.50 70.83 +13.33 [6.67, 21.67]
Average 66.94 70.67 +3.73 [0.22, 7.22]
MS-100-Ext Category Baseline PhysFlow Δ 95% CI
Linear 63.33 63.89 +0.56 [−3.89, 5.56]
Human / Complex 75.00 80.00 +5.00 [−4.44, 15.56]
Fluid / Particle 87.50 93.33 +5.83 [−1.67, 15.00]
Camera 62.22 63.89 +1.67 [0.00, 4.44]
Fine-grained Physics 60.00 65.83 +5.83 [1.67, 10.00]
Average 69.61 73.39 +3.78 [0.89, 6.83]

PhysFlow consistently outperforms the baseline on both MS-100 and MS-100-Ext, achieving average gains of +3.73 and +3.78 points, respectively, with both 95% confidence intervals excluding zero.

  • Robust across random seeds: The result is also robust across random seeds. The seed-level gains are +4.17, +2.00, and +5.00 on MS-100, and +6.00, +2.33, and +3.00 on MS-100-Ext. Thus, none of the six benchmark-seed combinations shows a negative change.
  • Whether the gain is driven by a small subset of examples: We analyze the paired prompt-level differences. PhysFlow improves 32 prompts, ties on 50, and decreases on 18 on MS-100. On MS-100-Ext, the corresponding counts are 23, 67, and 10. The improved prompts span multiple motion categories, showing that the aggregate gain is not restricted to a few isolated examples.

Q3: Human-Study Details

We thank the reviewer for requesting these details. We clarify each requested item below:

  • Participants and workload: The study involved 20 unique raters. Each completed 10 questionnaires containing 20 paired-seed comparisons. The comparisons were randomly sampled from a pool of 300 unique pairs, and the baseline and PhysFlow videos within each pair used the same prompt and random seed, resulting in 200 comparisons per rater, 4,000 pair-level evaluations, and 12,000 axis-level judgments.
  • Evaluation protocol: Each pair used the same prompt and random seed for the baseline and PhysFlow. Presentation order was randomized, and raters were blinded to method identity.
  • Rater-level aggregation: We first compute each rater’s response proportions on each axis and then average them equally across the 20 raters.
  • Confidence intervals: We use a two-way cluster bootstrap with 100,000 iterations, resampling both raters and paired-video items.
  • Compensation: Participation was voluntary and uncompensated.
  • Inter-rater agreement: Because raters evaluated overlapping but non-identical subsets, we use nominal Krippendorff’s α, which supports incomplete and unbalanced rating matrices. The mean α across the three axes is 0.4219.
  • Paired-seed preference rates: The table below reports the rater-aggregated response rates and their 95% confidence intervals.
Evaluation Axis PhysFlow Better Both Comparable Baseline Better
Motion Coherence 29.25% [25.23, 33.25] 63.38% [59.20, 67.80] 7.38% [4.10, 11.25]
Visual Detail 31.40% [27.73, 35.25] 51.16% [46.25, 56.50] 17.44% [13.78, 21.13]
Text-Prompt Alignment 14.93% [11.80, 18.20] 80.23% [76.70, 83.68] 4.85% [3.13, 7.13]

The preference margin is the PhysFlow-better rate minus the Baseline-better rate. Its confidence interval remains above zero for all three axes, with the largest margin on Motion Coherence. The high Both comparable rate, particularly for Text-Prompt Alignment, is expected because PhysFlow does not directly modify prompt semantics. The positive preference margins and inter-rater agreement support the human study as meaningful evidence of perceptual improvement.

We greatly appreciate your insightful and helpful comments, as they will undoubtedly help us improve the quality of our article. If our response has successfully addressed your concerns and clarified any ambiguities, we respectfully hope that you consider raising the score. Should you have any further questions or require additional clarification, we would be delighted to engage in further discussion.

Reviewer phYQ · CommentOpenReview ↗

comments

As the rebuttal response mainly resolved my concerns, I will maintain my score (Borderline Accept).

Authors · CommentOpenReview ↗

Additional Evaluation under Different Sampling-Step Budgets

We sincerely appreciate the reviewer’s acknowledgment that our rebuttal mainly resolve the concerns. We hope that these additional results and the clarified practical operating range further address the remaining concern and support a reconsideration of the assessment.

Robustness to reduced sampling steps. We thank the reviewer for highlighting the practical importance of few-step generation. We evaluate PhysFlow using 10 and 30 sampling steps while keeping the sampler and all other settings unchanged.

PhysFlow improves the average MotionStress score from 57.06 to 63.00 (+5.94) at 10 steps and from 64.33 to 68.67 (+4.34) at 30 steps. It improves 9 of the 10 category–step combinations. Importantly, because PhysFlow is applied over approximately 70% of the sampling trajectory, the 10-step setting provides only about seven active correction steps. The consistent improvement under this setting shows that the active schedule remains sufficiently dense for PhysFlow to operate effectively and that its benefit is preserved under commonly used reduced-step sampling.

These results refine the limitation stated in the original manuscript. The concern does not apply to the tested 10-step setting, but primarily to more aggressively compressed regimes, such as one- or very-few-step distilled models. In such cases, PhysFlow would have only one or a few opportunities to correct the trajectory, while the large transition between consecutive states may also weaken the local temporal smoothness assumption underlying the inter-frame derivative. We will revise the limitation to make this operating boundary clearer.

Category Baseline (10 steps) PhysFlow (10 steps) Baseline (30 steps) PhysFlow (30 steps)
Linear Motion 57.78 61.11 65.00 68.89
Human / Complex Motion 38.89 47.22 50.56 55.00
Fluid / Particle Dynamics 79.17 85.83 90.00 89.17
Camera Motion 49.44 56.67 54.44 62.78
Fine-grained Physics 60.00 64.17 61.67 67.50
Average 57.06 63.00 64.33 68.67
Reviewer 4GJ8OpenReview ↗
Rating
4/6
Confidence
3/5
Quality
2/4
Clarity
3/4
Significance
2/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

Flow-matching T2V models break down on motion-intensive prompts, producing fragmentation, deformation, and flickering. The paper argues that existing training-free fixes act at the wrong level and instead intervenes on the velocity field directly, with a closed-form additive correction at each sampling step. PhysFlow computes a per-frame "latent flow residual", then applies a diagnostic steering term, a straightness prior, a self-localizing residual mask, safe clipping, and a schedule that switches off during the last around 30% of steps, all reusing tensors the sampler already computes so there is no extra forward pass (1.00x cost). The paper also introduces MotionStress-100, a 100-prompt benchmark over five motion-failure families scored by a VLM (Qwen2.5-VL-7B) QA protocol, plus a prompt-extended variant. On Wan2.1-1.3B, PhysFlow gains +3.73 (MS-100) and +3.78 (MS-100-Ext) on average, beating FlowMo (2.12x cost) and CFG-Zero* while improving VBench motion smoothness. Appendices further add baseline sweeps, a 14B test, a small human study, and residual diagnostics.

Strengths and weaknesses

Strengths

  1. Correcting the velocity field with a closed-form update is clearly distinct from CFG-Zero*'s prompt-conditioning and FlowMo's gradient optimization, and the residual is derived from the probability-flow view of NSG-VD rather than being a bare heuristic.
  2. The ablation shows the diagnostic term is the active ingredient: removing it drops MS-100 below baseline (from 66.94 to 65.50). Appendix H also supports the mechanism claim: the residual decreases during the active window, rebounds after the schedule turns off, and the mask localizes to motion-heavy regions.
  3. True zero overhead (1.00x vs FlowMo's 2.12x), with one fixed hyperparameter set that transfers across prompts, benchmarks, and to the 14B model.

Weaknesses

  1. The gains are modest and uneven. On MS-100, most of the +3.73 average gain comes from fine-grained physics (from 57.50 to 70.83), with a smaller gain on Human (from 60.00 to 63.33). Linear, Fluid, and Camera move by less than one point. On Camera, PhysFlow is also the weakest of the three correction methods: 58.89 vs CFG-Zero* 60.56 and FlowMo 60.00. For a benchmark built around five failure families, this unevenness weakens the general motion-coherence claim.
  2. The effect fades on a stronger backbone. Appendix F is honest, but it cuts against the contribution: on 14B the average gain drops to +1.39, Linear and Human are unchanged, and again most of it is Fluid. This suggests the correction may become less important as the base model improves.
  3. The human study is too small to lean on. It uses 20 pairs and 200 axis-level responses, but the number of distinct raters and inter-rater agreement are not reported. "Both comparable" is the largest bucket on all three axes (63.4% for motion coherence, 51.2% for visual detail, and 80.2% for text alignment), so many pairs were rated as comparable. This only weakly supports the paper's claim that the gains are perceptible to human viewers.
  4. VBench evidence is marginal and partial. The absolute deltas are small (motion smoothness 0.9824 -> 0.9883), subject consistency drops on VBench-1 (from 0.9557 to 0.9530), and only 4 of 16 dimensions are reported.
  5. The primary metric relies on a single VLM judge on a new benchmark. MotionStress-100 is useful, but using only Qwen2.5-VL leaves judge robustness untested. CLIP-TC/DINO-TC and the human results help, but a second VLM judge or agreement analysis would make the evidence stronger.
Questions
  1. Can the authors report results on one non-Wan2.1 flow-matching backbone, such as CogVideoX or HunyuanVideo, using the same fixed hyperparameters? Even a small MS-100 run, or a representative subset covering all five categories, would help clarify generality.
  2. For the 14B experiment, is the baseline residual magnitude lower than in the 1.3B model? A residual-vs-step plot analogous to Figure 8 would help explain why the average gain drops to +1.39.
  3. Can the authors test judge robustness by rescoring MS-100 with a second VLM judge, or by reporting agreement/stability of per-category rankings with Qwen2.5-VL?
  4. For the human study, how many distinct raters contributed, how many ratings were collected per pair, and what was the inter-rater agreement? If feasible, expanding beyond 20 pairs with balanced category coverage would make this evidence stronger.
  5. Why does subject consistency drop on VBench-1? Can the authors report the full 16-dimension VBench table, or at least confirm whether any unreported dimensions regress?
Limitations

Yes.

Final justification

The additional experiments in rebuttal address most of my concerns, so I will raise my score from 3 to 4.

Formatting concerns

None observed. It appears to follow the NeurIPS 2026 format.

4 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We thank the reviewer for the valuable feedback. We are glad that the reviewer appreciates the contribution of our work. Below, we address the reviewer’s concerns one by one.

Q1 : Why are the gains uneven across MotionStress categories?

We thank the reviewer for highlighting this unevenness. The five MotionStress categories use different prompts and questions to emphasize distinct motion failure modes, so uniform gains are not necessarily expected. PhysFlow primarily targets local latent motion inconsistency and therefore benefits Fine-grained Physics most, where performance depends strongly on preserving object-level motion details, contact dynamics, articulation, and structural integrity. Human motion shows a smaller improvement for similar reasons. Overall, these results indicate that PhysFlow is particularly effective for local and object-centric motion failures, while its impact varies across motion categories with different evaluation emphasis.

Q2: Additional Video Backbones

We thank the reviewer for raising this important concern. We agree that evaluating PhysFlow beyond the Wan2.1 family is important. We evaluate PhysFlow on two additional flow-matching video backbones, HunyuanVideo-1.5 and Wan2.2, using the exact same implementation and fixed hyperparameters as used for Wan2.1, without any backbone-specific tuning or re-optimization. For Wan2.2, we use its default 121-frame generation setting. The results are summarized below:

Backbone Method Linear Human Fluid Camera Fine Physics Avg.
HunyuanVideo-1.5 Baseline 62.22 65.56 91.67 59.44 73.33 70.44
PhysFlow 61.67 68.89 94.17 60.00 76.67 72.28
Wan2.2 (121 frames) Baseline 65.56 51.11 88.33 58.89 59.17 64.61
PhysFlow 71.67 52.78 92.50 63.33 65.00 69.06

Without any backbone-specific adaptation, PhysFlow improves the average MotionStress score by +1.84 on HunyuanVideo-1.5 and +4.45 on Wan2.2. It clarifies that PhysFlow is a backbone-agnostic velocity regularization approach. We will include these additional experiments in the revised manuscript.

Q3: Effectiveness on the 14B Backbone

We thank the reviewer for this insightful question. We have tested models with various structure and size, by using the same fixed hyperparameters as Wan2.1-1.3B, without any backbone-specific tuning or re-optimization. The results are shown below:

Backbone Wan2.1-1.3B Wan2.2-TI2V-5B HunyuanVideo-1.5-8.3B Wan2.1-14B
MotionStress gain with PhysFlow +3.73 +4.45 +1.84 +1.39

The two backbones exhibit substantially different gains despite having similar parameter scales. This indicates that the available correction headroom depends not only on model size, but also on the backbone architecture, training distribution, and its remaining motion inconsistency under the evaluated prompts.

Due to the limited rebuttal period and the computational cost of regenerating and logging the full sampling trajectories of the 14B model, we have not yet completed this additional diagnostic experiment. We agree that a residual-versus-step comparison between the 1.3B and 14B backbones would provide a more direct mechanistic explanation and we will add the requested residual-versus-step comparison, together with the mean residual over the active correction window, in the revised version.

Q4: Robustness of the MotionStress VLM Judge

We thank the reviewer for this suggestion. We rescore the full MS-100 benchmark using GLM-4.6V-Flash as an independent VLM judge, while keeping the evaluated videos, category-specific questions, frame-sampling protocol, and score aggregation unchanged. The baseline and PhysFlow obtain MotionStress QA scores of 90.17 and 91.56, respectively, reducing the remaining error from 9.83 to 8.44, equivalent to a 14.1% reduction. Because absolute scores depend on judge-specific calibration, we focus on the relative comparison between methods. PhysFlow consistently outperforms the baseline under another VLM judge, demonstrating that the observed gain is not specific to a single evaluator.

Q5: Human Study Scale and Rater Agreement

We thank the reviewer for requesting these details. We clarify that the “20 pairs” refers to the number of paired-seed comparisons contained in each questionnaire, rather than the total number of evaluated pairs. The complete study covered 300 unique baseline–PhysFlow pairs.

  • How many distinct raters contributed: The study involved 20 distinct raters. Each rater completed 10 independently sampled questionnaires, with 20 paired-seed comparisons per questionnaire. The comparisons were randomly sampled from a pool of 300 unique pairs, and the baseline and PhysFlow videos within each pair used the same prompt and random seed.
  • How many ratings were collected per pair: Each rater provided 200 pair-level evaluations, resulting in 4,000 pair-level evaluations and 12,000 axis-level judgments across Motion Coherence, Visual Detail, and Text-Prompt Alignment. Across the 300 unique pairs, this corresponds to an average of 13.3 evaluations per pair, with unequal counts because of random questionnaire sampling.
  • What was the inter-rater agreement: We use nominal Krippendorff’s α rather than Fleiss’ κ, because the randomized questionnaire design produces an incomplete and unbalanced rater–item matrix. The mean nominal Krippendorff’s α across the three evaluation axes was 0.4219. This result indicates meaningful cross-rater agreement while accounting for the expected variability in subjective video comparisons.

Q6: Full VBench Results and Potential Regressions

We thank the reviewer for raising this concern. We originally reported four dimensions selected a priori based on methodological relevance: Temporal Flickering and Motion Smoothness directly evaluate temporal coherence, while Subject Consistency and Scene check whether the correction affects content preservation.

For completeness, we report all 16 VBench-1 dimensions under the same paired seeds {42,43,44,45,46}. PhysFlow improves 10 of 16 dimensions, while the descriptive unweighted mean increases from 0.6604 to 0.6638 (+0.51% relative).

VBench-1 Temp. Flicker Motion Smooth. Subject Cons. Background Cons. Dynamic Degree Scene Human Action Overall Cons. Spatial Relation Color Multiple Objects Object Class Imaging Quality Aesthetic Quality Temporal Style Appearance Style
Baseline 0.9895 0.9835 0.9571 0.9753 0.6388 0.2423 0.7500 0.2365 0.7342 0.8810 0.6145 0.7979 0.6872 0.6482 0.2333 0.1977
PhysFlow 0.9903 0.9886 0.9542 0.9697 0.6166 0.2735 0.7460 0.2379 0.7425 0.8799 0.6424 0.8076 0.6953 0.6417 0.2360 0.1988

The small changes in several dimensions should be interpreted cautiously because VBench provides broad proxy measurements rather than targeted evaluations of motion artifacts. For example, Subject Consistency is based on full-frame feature similarity and can vary with pose, viewpoint, subject scale, and composition even when identity remains stable. Similarly, Dynamic Degree measures the amount of visible motion rather than its coherence, so suppressing jitter or unstable displacement can reduce this score without degrading motion quality.

We therefore regard VBench as complementary, trend-level evidence. The full results show improvements in the targeted temporal dimensions and in several content-related dimensions, including Scene, Multiple Objects, Object Class, and Imaging Quality, without a systematic regression in general video quality. We will include the complete table and clarify this interpretation in the revision.

We greatly appreciate your insightful and helpful comments, as they will undoubtedly help us improve the quality of our article. If our response has successfully addressed your concerns and clarified any ambiguities, we respectfully hope that you consider raising the score. Should you have any further questions or require additional clarification, we would be delighted to engage in further discussion.

Authors · CommentOpenReview ↗

Additional Residual Analysis on Wan2.1-14B

We thank the reviewer for this helpful suggestion and repeat the residual-evolution analysis in Figure 8 on Wan2.1-14B. Residuals at different sampling steps are sequential observations along the same ODE trajectory rather than independent samples; therefore, endpoint differences represent net trajectory changes rather than accumulated intervention effects. Moreover, because the residual is a model-dependent internal control signal rather than a calibrated quality metric, its absolute magnitude should not be compared across backbone sizes. We therefore focus on within-backbone trajectory changes.

After the initial transient, the intensive- and simple-motion baseline curves remain relatively stable, with the intensive-motion baseline generally higher within each backbone, supporting the residual’s sensitivity to motion difficulty. We report three trajectory statistics: active-stage reduction, the residual decrease while PhysFlow is enabled; post-intervention rebound, the residual increase after PhysFlow is disabled; and final baseline–PhysFlow gap, the remaining separation between PhysFlow and the intensive-motion baseline at the final step.

Backbone Active-stage reduction, Step 5→35 Post-intervention rebound, Step 35→50 Final baseline–PhysFlow gap
1.3B 0.46 0.36 0.23
14B 0.50 0.43 0.18

The active-stage reduction is comparable across the two backbones and slightly larger on 14B. Thus, the smaller perceptual gain on 14B cannot be simply attributed to a weaker active-stage correction. After PhysFlow is disabled, however, 14B exhibits a somewhat larger rebound and retains a smaller final separation from its own baseline. This rebound does not by itself imply degraded video quality, because the residual is not a calibrated perceptual metric and the final 30% of sampling is reserved for the pretrained dynamics to refine appearance details. Together with the stronger 14B baseline and its smaller remaining perceptual headroom, this within-backbone behavior is consistent with the smaller final improvement observed on 14B.

Reviewer 4GJ8 · CommentOpenReview ↗

Thank you for the detailed rebuttal. The additional experiments address most of my concerns, so I will raise my score to 4.

Authors · CommentOpenReview ↗

Thank you very much for your positive feedback. We are glad that the additional experiments and clarifications addressed your concerns. We sincerely appreciate your thoughtful evaluation and helpful suggestions, which have improved our work. We are very grateful for your decision to raise the score to 4.

Reviewer KiC9OpenReview ↗
Rating
4/6
Confidence
3/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper studies local motion failures in flow-matching text-to-video models under motion-intensive prompts, such as object fragmentation, geometric deformation, limb artifacts, and temporal flickering. The authors propose PhysFlow, a training-free inference-time velocity regularization method. It builds a latent flow residual from the frame-wise latent difference and the sampler-predicted velocity, then applies a bounded velocity correction using a diagnostic term, a straightness prior, a residual mask, safe clipping, and an early-stage schedule. The paper also introduces MotionStress-100 and a prompt-expanded variant, using five motion-stress prompt categories and a VLM yes/no QA protocol to evaluate motion-specific failures. Experiments are mainly conducted on Wan2.1-T2V, with comparisons to the original sampler, CFG-Zero*, and FlowMo, plus selected VBench metrics, component ablations, a Wan2.1-14B follow-up experiment, and a small human preference study.

Strengths and weaknesses

Strengths

  1. The paper targets a clear and important failure mode in current text-to-video models: motion-intensive prompts often produce fragmentation, deformation, and flickering that broad benchmarks can miss.

  2. PhysFlow is a clean training-free intervention. It acts directly on the sampling velocity, uses quantities already available during inference, and the timing results in Table 1 support the near-baseline cost claim.

  3. The ablation in Table 3 gives some evidence that the residual-driven diagnostic term matters. Removing it drops the average MotionStress score from 70.67 to 65.50, while removing only the straightness prior has a smaller effect.

  4. MotionStress-100 is a useful benchmark direction. A targeted prompt set for motion failures is valuable, even if the current evaluation protocol still needs stronger validation.

Weaknesses

  1. The evidence for generality is limited. Almost all main experiments use Wan2.1-T2V-1.3B, and the 14B result is still within the Wan2.1 family. There is no test on CogVideoX, HunyuanVideo, or another video backbone.

  2. The main metric depends on Qwen2.5-VL-7B yes/no judgments. The human study helps, but it uses only 20 video pairs, and I could not find a clear report of independent rater count or human-human agreement.

  3. The "physics-intrinsic" framing seems stronger than the evidence supports. Appendix H.1 presents the residual as a latent-space control signal, not as a calibrated physical conservation law in pixel space.

  4. The reported gains are positive but modest. The MS-100 and MS-100-Ext average gains are about 3 to 4 points, and the gap to the best tuned baseline in Appendix D is about 2.7 points.

  5. Reproducibility is incomplete during review. The paper says the code, MotionStress prompts, and evaluation scripts will be released after acceptance, but these assets are important for checking a new benchmark and VLM-based evaluation protocol.

Questions
  1. The paper should include results on another backbone, such as CogVideoX or HunyuanVideo. The method is motivated as a velocity-level correction for flow-matching video generation, but the current evidence is almost entirely within the Wan2.1 family.

  2. The MotionStress QA protocol needs stronger validation. I would like to see, at minimum, the correlation between Qwen2.5-VL judgments and human preferences, stability under another VLM judge, category-level confidence intervals, and the number of independent human raters with their agreement.

  3. The residual-to-artifact link is still somewhat indirect. The current evidence mainly comes from ablations and a few visualizations. A correlation between residual magnitude and human or VLM failure labels, or a failure-rate breakdown by residual bucket, would make the diagnostic claim stronger.

  4. Please report the full VBench results, at least in the appendix. The current paper reports temporal flickering, motion smoothness, subject consistency, and scene, but the omitted dimensions may reveal trade-offs.

  5. For reproducibility, the anonymized MotionStress prompt list, VLM judge prompts, and evaluation scripts should be available during review. These files are needed to check the benchmark design, the yes/no question protocol, and the baseline comparisons.

Limitations

see weaknesses

Formatting concerns

No

1 comment
Authors · RebuttalOpenReview ↗
Rebuttal

We thank the reviewer for the valuable feedback. We are glad that the reviewer appreciates the contribution of our work. Below, we address the reviewer’s concerns one by one.

Q1: Effectiveness on Other Video Backbones

We thank the reviewer for raising this important concern. We agree that evaluating PhysFlow beyond the Wan2.1 family is important, we evaluate PhysFlow on two additional flow-matching video backbones, HunyuanVideo-1.5 and Wan2.2, using the exact same implementation and fixed hyperparameters as used for Wan2.1, without any backbone-specific tuning or re-optimization. For Wan2.2, we use its default 121-frame generation setting. The results are summarized below:

Backbone Method Linear Human Fluid Camera Fine Physics Avg.
HunyuanVideo-1.5 Baseline 62.22 65.56 91.67 59.44 73.33 70.44
PhysFlow 61.67 68.89 94.17 60.00 76.67 72.28
Wan2.2 (121 frames) Baseline 65.56 51.11 88.33 58.89 59.17 64.61
PhysFlow 71.67 52.78 92.50 63.33 65.00 69.06

Without any backbone-specific adaptation, PhysFlow improves the average MotionStress score by +1.84 on HunyuanVideo-1.5 and +4.45 on Wan2.2. It clarifies that PhysFlow is a backbone-agnostic velocity regularization approach. We will include these additional experiments in the revised manuscript.

Q2: Validation of the VLM-Based Evaluation Protocol and User Study

We thank the reviewer for requesting stronger validation of the MotionStress QA protocol. We provide four additional analyses:

  • Human alignment: At the paired-video level, human Motion Coherence preferences are encoded as +1/0/−1 and averaged across raters, while the VLM signal is the PhysFlow–baseline difference in Qwen2.5-VL scores. Their Spearman correlation is ρ=0.4362, comparable to Video-Bench’s reported correlations for Temporal Consistency (0.402) and Motion Effects (0.514).
  • Another VLM judge: GLM-4.6V-Flash also favors PhysFlow on MS-100, scoring 90.17 vs. 91.56 (+1.39), equivalent to a 14.1% relative error reduction.
  • Uncertainty: A category-stratified paired bootstrap with 100,000 resamples gives overall gains of +3.73 [0.22, 7.22] on MS-100 and +3.78 [0.89, 6.83] on MS-100-Ext. Both overall confidence intervals exclude zero, while category-level intervals are wider due to the smaller sample size per category. | Category | Baseline | PhysFlow | Δ | 95% CI of Δ | | --- | --- | --- | --- | --- | | Linear | 65.56 | 66.11 | +0.56 | [-6.67, 8.33] | | Human / complex | 60.00 | 63.33 | +3.33 | [-7.78, 13.33] | | Fluid / particle | 93.33 | 94.17 | +0.83 | [-5.00, 6.67] | | Camera | 58.33 | 58.89 | +0.56 | [-6.67, 7.22] | | Fine-grained physics | 57.50 | 70.83 | +13.33 | [6.67, 21.67] | | Avg. | 66.94 | 70.67 | +3.73 | [0.22, 7.22] |
Category(With prompt extend) Baseline PhysFlow Δ 95% CI of Δ
Linear 63.33 63.89 +0.56 [-3.89, 5.56]
Human / complex 75.00 80.00 +5.00 [-4.44, 15.56]
Fluid / particle 87.50 93.33 +5.83 [-1.67, 15.00]
Camera 62.22 63.89 +1.67 [0.00, 4.44]
Fine-grained physics 60.00 65.83 +5.83 [1.67, 10.00]
Avg. 69.61 73.39 +3.78 [0.89, 6.83]
  • Human raters and agreement: The study involved 20 independent raters, each completing 10 questionnaires with 20 paired-seed comparisons. The comparisons were randomly sampled from a pool of 300 unique pairs, and the baseline and PhysFlow videos within each pair used the same prompt and random seed. This resulted in 4,000 pair-level evaluations and 12,000 axis-level judgments. Because random sampling produces an incomplete and unbalanced rater–item matrix, we use nominal Krippendorff’s α, obtaining a mean agreement of 0.4219 across the three evaluation axes.

Together, these results demonstrate that MotionStress QA is meaningfully aligned with human motion judgments, directionally stable across VLM judges, and supported by category-level uncertainty estimates and independent human evaluation.

[1] Han et al. Video-Bench: Human-Aligned Video Generation Benchmark. CVPR 2025.

Q3: Residual–Artifact Correlation Analysis

We thank the reviewer for this suggestion. We conduct an additional baseline-only diagnostic analysis on 45 generated videos. For each video, we record the maximum absolute latent flow residual, max⁡∣rf∣, at the final (50th) sampling step, before applying any PhysFlow correction. We then evaluate the same decoded videos using MotionStress QA and divide them into three equal-sized groups according to residual magnitude:

Residual group Residual range Mean max Mean VLM QA VLM failure rate
High residual 7.7989–9.1079 8.2475 62.22% 37.78%
Medium residual 7.2509–7.7605 7.4667 64.44% 35.56%
Low residual 6.7535–7.2363 7.0665 73.33% 26.67%

Here, the VLM failure rate is defined as 1-MotionStress QA score. The results show a clear monotonic trend: videos with larger residuals receive lower MotionStress QA scores and exhibit higher estimated failure rates. In particular, the high-residual group has an average QA score 11.11 percentage points lower than the low-residual group, with the corresponding failure rate increasing from 26.67% to 37.78%.

This analysis provides direct video-level evidence that the baseline residual is associated with downstream motion-related artifacts, complementing the correction ablations and residual-curve visualizations in Appendix H. We emphasize that the residual is not intended as a calibrated physical quantity or a causal artifact measure; rather, it serves as a useful diagnostic signal for identifying generations that are more likely to contain motion failures.

Q4: Complete VBench Results

We thank the reviewer for raising this concern. We originally reported four dimensions selected a priori based on methodological relevance: Temporal Flickering and Motion Smoothness directly evaluate temporal coherence, while Subject Consistency and Scene check whether the correction affects content preservation.

For completeness, we report all 16 VBench-1 dimensions, PhysFlow improves 10 of 16 dimensions, while the descriptive unweighted mean increases from 0.6604 to 0.6638 (+0.51% relative).

VBench-1 Temp. Flicker Motion Smooth. Subject Cons. Background Cons. Dynamic Degree Scene Human Action Overall Cons. Spatial Relation Color Multiple Objects Object Class Imaging Quality Aesthetic Quality Temporal Style Appearance Style
Baseline 0.9895 0.9835 0.9571 0.9753 0.6388 0.2423 0.7500 0.2365 0.7342 0.8810 0.6145 0.7979 0.6872 0.6482 0.2333 0.1977
PhysFlow 0.9903 0.9886 0.9542 0.9697 0.6166 0.2735 0.7460 0.2379 0.7425 0.8799 0.6424 0.8076 0.6953 0.6417 0.2360 0.1988

The small changes in several dimensions should be interpreted cautiously because VBench provides broad proxy measurements rather than targeted evaluations of motion artifacts. For example, Subject Consistency is based on full-frame feature similarity and can vary with pose, viewpoint, subject scale, and composition even when identity remains stable. Similarly, Dynamic Degree measures the amount of visible motion rather than its coherence, so suppressing jitter or unstable displacement can reduce this score without degrading motion quality.

We therefore regard VBench as complementary, trend-level evidence. The full results show improvements in the targeted temporal dimensions and in several content-related dimensions, including Scene, Multiple Objects, Object Class, and Imaging Quality, without a systematic regression in general video quality. We will include the complete table and clarify this interpretation in the revision.

Q5: Reproducibility and Evaluation Resource Release

We thank the reviewer for raising this important reproducibility concern. We provide the detailed descriptions in the appendix A, including the benchmark construction, prompt categories, VLM judge instructions, and yes/no evaluation protocol.

For transparency and reproducibility, we have shared an anonymized repository with the Area Chair through an Official Comment. It contains the MotionStress prompt list, the category-specific yes/no evaluation questions, and the Qwen2.5-VL evaluation script, allowing the benchmark design and VLM-based evaluation protocol to be inspected during review. The released materials also clarify the scoring and aggregation procedure used for the reported MotionStress comparisons.

These resources allow the community to reproduce the benchmark construction, VLM-based evaluation pipeline, and baseline comparisons. We will release the full repository publicly upon acceptance.

We greatly appreciate your insightful and helpful comments, as they will undoubtedly help us improve the quality of our article. If our response has successfully addressed your concerns and clarified any ambiguities, we respectfully hope that you consider raising the score. Should you have any further questions or require additional clarification, we would be delighted to engage in further discussion.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Missing a submission?

Loading the discussion…