NeuralBES: A Differentiable, Control-Aware Emulator for Scalable Building Energy Modeling

Ting-Yu Dai, Takuya Kurihana, Wing Yee Au, HON YUNG WONG

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

Abstract. Demand-side flexibility, i.e., forecasting, shifting, and curtailing residential energy loads, depends on thermal models trusted across millions of heterogeneous buildings. Existing tools force a hard tradeoff: high-fidelity physics simulators such as EnergyPlus are accurate but sequential and require per-building calibration, while purely data-driven sequence models scale but abandon the physical structure that makes their predictions trustworthy.

We introduce NeuralBES (Building Energy Simulation), a differentiable emulator that resolves this tradeoff by parameterizing a resistance--capacitance (RC) based thermal model with a shared neural encoder: static building metadata such as floor area, vintage, and HVAC type is mapped to physically bounded capacitances, conductances, and equipment coefficients, which become the coefficients of a scalar linear recurrence solved via a log-space parallel scan, and a predictor--corrector loop closes the thermostat--temperature nonlinearity while preserving full-horizon gradient flow. Trained on the ResStock dataset across three climate zones, NeuralBES handles heterogeneous building archetypes, vintages, and climate zones within a single trained encoder, while black-box baselines produce statistically plausible but physically inconsistent trajectories. On the annual full-year rollout, NeuralBES reproduces realistic HVAC idle periods and duty cycles, which determine annual energy and peak-load estimates. It reduces the MAPE by more than half compared to an equally sized grey-box RC baseline that shares its metadata encoder, while an unconstrained LSTM attains lower pointwise error.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
30 Apr 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:43 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

The authors propose a new neural emulator for building energy simulation. All reviewers agree on the novelty of the contribution and the general potential for impact of this work, also praising the quality of the presentation and writing. While two reviewers provide accept scores, they do so with lower confidence. Reviewer q6HF has the highest confidence score and currently recommends rejection based on several shortcomings, most importantly the fairness of the comparisons conducted in the study and claims around the approaches transferrability. I'd strongly encourage the authors to engage with this detailed review as I believe it highlights several areas of improvement of the current manuscript.

Final justification

The authors submitted substantial rebuttals to the reviewers, leading to a great discussion with reviewer q6HF. Overall, the authors responded positively to the rebuttal and the paper now has all accept scores. I also encourage the authors to integrate some of the suggestions made by the reviewers after the rebuttal, especially 6qt2's suggestion on integrating more practical examples into the writing to contextualize the work. Furthermore, there's one hallucinated reference in the paper: @article{zhang2021grey, author = {Zhe Zhang and Adrian Chong and Yuzhen Pan and Chi Zhang and Khee Poh Lam}, title = {Grey-box modeling and application for building energy simulations—a critical review}, journal = {Renewable and Sustainable Energy Reviews}, volume = {146}, pages = {111174}, year = {2021}, doi = {10.1016/j.rser.2021.111174} } The authors in the provided citation ('Zhe Zhang', 'Adrian Chong', 'Yuzhen Pan', 'Chi Zhang', 'Khee Poh Lam') are completely incorrect. The actual authors of the paper are Yanfei Li, Zheng O'Neill, Liang Zhang, Jianli Chen, Piljae Im, and Jason DeGraw.

I recommend acceptance.

Area Chair xYKH · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

The authors propose a new neural emulator for building energy simulation. All reviewers agree on the novelty of the contribution and the general potential for impact of this work, also praising the quality of the presentation and writing. While two reviewers provide accept scores, they do so with lower confidence. Reviewer q6HF has the highest confidence score and currently recommends rejection based on several shortcomings, most importantly the fairness of the comparisons conducted in the study and claims around the approaches transferrability. I'd strongly encourage the authors to engage with this detailed review as I believe it highlights several areas of improvement of the current manuscript.

Final justification

The authors submitted substantial rebuttals to the reviewers, leading to a great discussion with reviewer q6HF. Overall, the authors responded positively to the rebuttal and the paper now has all accept scores. I also encourage the authors to integrate some of the suggestions made by the reviewers after the rebuttal, especially 6qt2's suggestion on integrating more practical examples into the writing to contextualize the work. Furthermore, there's one hallucinated reference in the paper: @article{zhang2021grey, author = {Zhe Zhang and Adrian Chong and Yuzhen Pan and Chi Zhang and Khee Poh Lam}, title = {Grey-box modeling and application for building energy simulations—a critical review}, journal = {Renewable and Sustainable Energy Reviews}, volume = {146}, pages = {111174}, year = {2021}, doi = {10.1016/j.rser.2021.111174} } The authors in the provided citation ('Zhe Zhang', 'Adrian Chong', 'Yuzhen Pan', 'Chi Zhang', 'Khee Poh Lam') are completely incorrect. The actual authors of the paper are Yanfei Li, Zheng O'Neill, Liang Zhang, Jianli Chen, Piljae Im, and Jason DeGraw.

I recommend acceptance.

Reviewer NfftOpenReview ↗
Rating
5/6
Confidence
3/5
Quality
3/4
Clarity
4/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

NeuralBES is a model sitting in between accurate but unscalable physics-based building energy model simulators and scalable but physically unreliable data-driven models. Physics-based building energy models do not scale because they would need to be calibrated for an unfeasibly large number of homes. While data-driven models are scalable, their results are not interpretable and are not guaranteed to be physically realistic. NeuralBES targets a middle space simulating building energy using only metadata commonly found in tax assessor records and scales to millions of buildings and new climates while retaining physical interpretability. NeuralBES uses a shared encoder (across all buildings) to estimate a target building’s resistance and capacitance values based on common inputs. The use of a shared encoder avoids the need for building-specific calibration and predicting resistance and capacitance values which feed into a physically-based simulation (as opposed to freely predicting temperature straight from building metadata which wouldn’t enforce physical processes on the model, such as the buildings capacity to absorb heat). To achieve this the model is trained using ResStock (large dataset of building types) and End-Use Load Profiles (meter readings of electricity use); this large scale training allows the model to generalise. At the same time the training signal for the model is based on physical models (DOE-2 and EnergyPlus) which teaches the AI model physical relationships between thermal states and heating / cooling equipment. NeuralBES is compared to a range of ML baselines and a grey box RC model demonstrating it is physically bounded (compared to baseline ML) and achieves better performance compared to a grey box RC model.

Strengths and weaknesses

This is not my area of expertise, so I am not best placed to judge originality and significance of this work within its field. However, I thought it was very well presented, accessible, and high-quality paper. I would recommend acceptance if that aligned with reviewers with subject matter expertise.

Overall, the paper was well written with a clear structure that made the work accessible and engaging; this helped communicate and explain the (relatively complex) approach the authors took to ensure their ML solution was physically based. The succinct introduction, followed by a clearly structured positioning of NeuralBES against existing work, before a detailed but well written methods provided a layered description and explanation of the approach developed here. Further, the BEM primer in the appendix was a good addition contributing to making this work accessible to general readers and is indicative of the quality of the overall presentation / communication of this work. The initial results comparing NeuralBES to baseline models was clear, but some of the additional interpretation of baseline models versus NeuralBES was hard to follow without a more detailed explanation of the baselines (as discussed below).

The authors clearly articulates NeuralBES’s original contribution versus existing and alternative building energy modelling approaches (grey box models are too costly to calibrate per-building at scale; NeuralBES differs from other physics-informed neural models by imposing a fixed RC-structure learning coefficients rather than dynamics and using a predictor-corrector loop to handle a thermostats on/off behaviour). This is achieved through large-scale training (via ResStock and End-Use Load Profile datasets) but using physical models (DOE-2 and EnergyPlus) to provide the training signal. This allows NeuralBES to scale simulations to a large number of while remaining physically bounded and using a conservation-law backbone, which sets it apart from other emulation approaches as set out in Section 2. Also, the innovations presented here allowing temperature simulations to be run in parallel as opposed to sequentially were interesting, well motivated, and dovetailed nicely with the stated aims of running across large building stocks.

A core strength of this paper is how this work is positioned against both unscalable physical models and scalable, but physically unrealistic, data-driven models. The paper does present a comparison of NeuralBES against a suite of different ML models and demonstrates it outperforms them while remaining physically bounded and states these baselines span the inductive bias spectrum with a limited description of the baseline architectures in tables 4 and 5 in the appendix. There is scope to more clearly explain the differences between these baseline approaches and why each of them are useful as comparisons to NeuralBES. I note the authors include a grey box RC baseline model, and this might be me overlooking something with my limited experience of these models, but I would welcome further explanation of this baseline model and how this is different from the unscalable physical models that NeuralBES is positioned against. A more complete explanation of the baseline models would have helped with interpreting Figure 3 and the related discussion in the final three sub-sections of section 4.2.

I was also curious as to the difference in performance of NeuralBES versus a “best-practice” physical model, even if this was for a small sample of test set buildings. I think that would be useful ancillary analysis to ascertain how close NeuralBES is to bridging the gap to physical models. How does an RMSE of 2.78 dec C for NeuralBES compare to physical models and what does this error mean for applied uses of the model?

Questions

How did the performance of NeuralBES vary with different types of buildings?

With an RMSE of 2.78 deg C, what downstream applications can this model be used for? And, what is the gap in accuracy of NeuralBES to purely physical based models?

Part of the motivation for NeuralBES was to scale to large numbers of buildings. How far away is NeuralBES from being used for these kinds of analyses? And what would be the impact of being able to undertake such analysis? Addressing these points in conclusion / limitations sections would be useful and round the paper off.

Limitations

Broadly, yes. However, as stated above I think there is scope for further explanation of the baseline comparison models and also contextualising the model’s performance relative applied uses.

Final justification

I thank the authors for their detailed rebuttal. Overall, I thought this was a well positioned and written paper and interesting analysis. I would strengthen my recommendation for publication if a more detailed explanation of the baseline and benchmark models was added to the manuscript. However, this is not my area of expertise so I will refer to other reviewers with domain expertise for comments on the novelty of this work.

Formatting concerns

N?A

1 comment
Authors · RebuttalOpenReview ↗
Rebuttal

Response to Reviewer Nfft

We thank the reviewer for the positive assessment and for highlighting where the empirical scope and baseline roles need clearer explanation.

Baselines and the revised comparison

We will explain the comparison spectrum more directly: DLinear is a linear forecasting baseline; LSTM is recurrent; PatchTST and Roformer are attention-based black boxes; PI-Roformer adds a soft heat-balance residual to a Roformer trunk; RC Grey-Box performs a structured RC rollout; and NeuralBES combines that rollout with learned auxiliary physics and predictor–corrector control. Classical identified grey-box RC models are calibrated separately for each building. To create a population-scale, input-matched baseline, we equip the RC Grey-Box with the same metadata-to-parameter encoder architecture as NeuralBES (with independently trained weights), so both infer building-specific 3R2C coefficients from coarse metadata rather than receiving per-building calibrated parameters. The remaining difference is the rollout formulation: RC uses fixed COPs and a fixed setpoint band, whereas NeuralBES adds learned internal gains, wind-dependent infiltration, COP derating, schedule-aware setpoints, and predictor–corrector control; we will also equalize the currently unequal training-window overlap.

We will also revise the headline interpretation consistently with our response to Reviewer q6HF: a capacity-matched LSTM beats NeuralBES on every raw-error metric, and simple signed-QQ/clipping projections repair pointwise mode exclusivity and bounds. Thus we will not claim that NeuralBES outperforms all baselines or uniquely lies on an accuracy/validity frontier; the narrower empirical advantage is off-state and duty-cycle fidelity.

Accuracy, heterogeneity, and the physical-model gap

EnergyPlus is the detailed physical simulator that generated the ResStock targets, not an additional predictor evaluated from the same coarse inputs. Therefore, the reported 2.79 °C annual TairT_{air} RMSE is precisely NeuralBES's emulation error relative to EnergyPlus under known weather, schedules, and occupancy; it is not a gap to measured reality. NeuralBES should not be presented as a replacement for design-grade simulation, comfort certification, or safety-critical building control. Its intended scope is population-level scenario screening, annual/load-shape studies, tariff and demand-response analysis, and retrofit prioritization. We have not yet validated a downstream decision metric directly, and will state that clearly.

The current paper reports regional rather than building-type stratification. This does not establish uniform performance across vintages, building types, or HVAC classes; we will add that stratified analysis or explicitly identify its absence as a limitation. Our new leave-one-region-out test further shows that temperature dynamics transfer better than load magnitude: held-out-region TairT_{air} changes by at most +0.12 °C and improves in two regions, while load MAPE worsens by 3–10 percentage points.

Readiness and scale

We agree that “scales to millions” was stronger than the evidence. We did not run a million-building throughput benchmark. The demonstrated advantage is reduced per-building input and calibration burden, not measured deployment scale. Before stock-scale operational use, the method still needs explicit throughput benchmarks, broader geographic and building-type evaluation, validation against measured data, forecast rather than perfect exogenous inputs, and support for modulating or more complex controls. We will revise the conclusion to distinguish this intended impact from demonstrated readiness.

For precision, NeuralBES is trained on synthetic ResStock/EnergyPlus trajectories; End-Use Load Profiles provides aggregate calibration context for the corpus rather than direct meter-level supervision of NeuralBES.

Reviewer q6HFOpenReview ↗
Rating
4/6
Confidence
4/5
Quality
2/4
Clarity
3/4
Significance
2/4
Originality
3/4
Contribution type
use_inspired
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper introduces NeuralBES, a physics-aware approach to modeling building temperature and HVAC characteristics. It uses a learned encoder to map static building metadata (ex. floor area, HVAC type, building type, occupancy, etc.) and time-varying signals (weather, occupancy, appliance schedules, etc.) to predict coefficients of the continuous-time heat balance equations for zone air and building mass temperature in a 2 node RC model. These coefficients are then used to derive a closed form solution (state-space model) for discrete-time temperature steps, which are solved in parallel using a (log-space) associative scan formulation. The proposed NeuralBES model is evaluated using data of several buildings from 3 distinct cities from the ResStock dataset, using EnergyPlus simulations to provide the ground truth. Evaluation metrics are around prediction accuracies of HVAC heating / cooling injections and zone air temperature, as well as prediction feasibility (simultaneous heating/cooling and temperature bounds). Baselines are black-box data-driven models such as LSTM and a grey-box 2R2C model.

Strengths and weaknesses

Strengths

  • Clearly written paper, well-presented, and straight-forward (focusing on the key details of the problem and the proposed architecture). Quite pleasant to read.
  • Very interesting idea to predict physics coefficients that then power an established state-space technique. Not only does the technique rely on less building metadata (which is often missing, incorrect, or incompatible in the first place [1,2]), but I can also see how this can be attractive for diagnosis/interpretability.
  • The parallelization was also a cool trick, of course.
  • Comprehensive and well-structured appendix with addition details that proactively answer several questions a reader may have.

[1] Bass, Brett, et al. "How close are urban scale building simulations to measured data? Examining bias derived from building metadata in urban building energy modeling." Applied Energy 327 (2022): 120049.
[2] Pritoni, Marco, et al. "Metadata schemas and ontologies for building energy applications: A critical review and use case analysis." Energies 14.7 (2021): 2024.

Weaknesses

Major

  • The motivation seems misaligned with study analysis. In the intro the authors claim scalability issues with classical BEM* and the issue of trustworthiness under distribution shift with data-driven emulators, but their study does not evaluate either of these things.
  • In the introduction the authors say that NeuralBES "transfers across heterogeneous buildings and climates", which is misleading because the method is transferable but this makes it sound like their model can be used for generalization or transfer learning, which is not evaluated. While the evaluation contains different buildings from different regions, models are only ever evaluate in isolated state experiments or with all state data together, i.e. there are no transfer experiments. Additionally, they specifically do stratified splitting, such that all evaluations are in-distribution tests.
  • Judging by Equations 1 and 2, the authors use a 3R2C model but their RC model comparisons are all 2R2C models (both the RC Grey-Box and the PI-Roformer). This does not seem like a fair comparison.
  • The lack of physics-aware data-driven baselines makes the paper's evaluation feel incomplete, particularly considering that the most performant models at predicting T (despite violations) were indeed the NN models. It is uncertain how any of the physics-aware models of Table 1 compare to these black-box models and NeuralBES in terms of accuracy and feasibility.
  • The LSTM clearly performed better in terms of prediction accuracy and the authors claimed this is a result of model size, but do not have any capacity-matched experiments to confirm this. They themselves flag this as a known limitation, and I would agree that this impacts the credibility of the conclusions.
  • The paper assumes that the thermostat behavior is ideal and tries to teach the model to learn the exact energy injection patterns (qheatq_{heat} and qcoolq_{cool}) of an idealized, simple thermostat. Thus, the model's real-world applicability is restricted strictly to buildings with this rigid control logic of turning off and on upon passing threshholds. This should be made clear as an assumption / limitation of applicability. I believe the primary evaluation of a model's true predictive accuracy and transferability should be based on the resulting room temperature (TairT_{air}), unless the Q injections are specifically needed for the downstream task. Note: Looking at the Fall charts in Figure 3, it seems like there are times in which heating and cooling are both non-zero for the ground truth data, which would imply that the ground-truth is not physically consistent in the first place.
  • (Seemingly) False conclusions
    • In Figure 2 it says "NeuralBES and RC give the physically expected monotone slope; Roformer and PI-Roformer over-react". However, in negative perturbations, LSTM and NeuralBES are closer than NeuralBES and RC, so this grouping feels arbitrary and untrue.
    • On line 306, it says "On TinT_{in}, NeuralBES tracks envelope-driven excursions in summer and fall while LSTM and PatchTST flatten toward the setpoint mean". However, in summer, NeuralBES just predicts static results (just below 28 degrees), which seems very poor, and in fall NeuralBES seems to track just as well as LSTM.

Minor:

  • The authors should make sure they have declared / explained all variables used in their equations. Many can be deduced from context/background knowledge, but explaining variables such as Qbint,convQ_b^{int,conv} would allow for a smoother reading experience. Additionally, the authors use TinT_{in} as the target variable (such as in Table 2), but should either explicitly say this is TairT_{air}, or only use one of these variable names throughout.
  • On line 274, the authors likely meant to use rather than ≥ϵ\ge \epsilon, rather than −ϵ-\epsilon, unless they are allowing these values to be negative for some unknown reason...
Questions
  • Model Training/Evaluation
    • Regarding the "Evaluation Protocol" paragraph of section 4, when training on the 672-step windows, is this referring to the model training using the training set, or a sort of fine-tuning step used before the evalution on the test set?
      • If the former: Is backpropogation done on every predicted time step, by combining (ex. average) several time steps, or only once at the end? Does this mean that only 1/52th of all building data is used for training?
      • If the latter: How did you choose this tuning period? Is there a standard time period in practice or from existing literature?
    • Are your models operating under the assumption that you have perfect information for the other variables such as weather, equipment, and occupancy behaviour? This should be made clear and if necessary listed as a limitation, of course.
  • Shared static encoder:
    • How do you actually share the static encoder between models, and which models make sure of this? Do you first train your NeuralBES and use the finished encoder as input to the other models? Do you have ground truth to inform how accurate the encoder is? Because coefficient accuracy naturally has a large impact on how well the baselines perform (for ex. in the presence of inaccurate information, the LSTM may perform better without some of this info at all). It would probably make sense for the other methods to get the true values (and then the paper emphasize that the benefit of their method is good/better prediction using less information), or at the very least make a justification why it is ok to give the other models not incorrect information.
  • RC Grey-Box
    • How does this model actually differ from the one used in NeuralBES? The paper says "fixed COPs and a fixed setpoint band", but if they use the same static encoder, it is not clear to me how the outputs can be different. Perhaps due to the predictor-corrector algorithm, but this would then change the encoder (no?) and thus the encoders would no longer be the same. Also, is this model a 2R2C, while your main model is 3R2C?
  • LSTM Baseline Feasibility
    • Regarding the feasibility bounds, how do you think this would this change if you simply clip the Q_heat/cool output? Seems like an easy feasibility fix. Similarly, only outputting on value for Q, where pos means heat and neg means cool (or use two variables but only use the max to determine if heat or cool) seems like it would eliminate mode exclusivity issues. Ignoring these simple fixes makes the LSTM baseline appear artificially weak.
  • To what degree can the results of NeuralBES be properly compared to other physics-aware neural network methods? The paper lacks a direct comparison, which feels like a big limitation considering this is positions as a physics-aware method, and the only commentary is the fact that it would require engineering effort to make this comparison, which does not feel sufficient.
  • When does predicting Qheat/cool actually matter? When trying to predict temperature, it does not seem to be that important what the intermediate variables are, so what is the motivation for using the Qs (and therefore also mode exclusivity) as evaluation criteria? To what degree is the physical consistency even important here?

Note: While the current baselines and not-fully-supported claims limit the paper's impact, addressing the structural fairness of the comparisons (e.g., matching R/C capacities, fixing/clipping the LSTM, clarifying the encoder sharing, evaluating/improving justification of lack of SOTA physics-aware models) and tempering the claims around transferability could warrant a re-evaluation of the score.

Limitations
  • The authors were upfront about the lack of capacity-matched experiments for the LSTM baseline, which is appreciated, and agreed to be a limitation.
  • Since the evaluation relies entirely on stratified splitting using regions present in the training set, and thus only in-distribution performance is tested. True out-of-distribution transferability or generalization remains unverified and should be explicitly listed as a limitation (or the claims in the introduction should be tempered).
  • The core evaluation uses 2R2C baselines but the NeuralBES model contains a 3R2C model, I believe, creating an inherent structural imbalance.
  • The lack of physics-aware data-driven baselines leaves a gap in understanding how the proposed method compares to a complete spectrum of existing solutions.
  • The model relies on the assumption of an idealized, rigid thermostat behavior (turning on/off perfectly at thresholds). This heavily restricts real-world applicability.
Final justification

Despite its weaknesses, this paper indeed has a relevant use case, some interesting ideas, a well-tailored methodology, promising results, and transparency of limitations that could be valuable for the broader community, particularly in its BEM application domain.

Existing weaknesses include: Limited / no benefit for temperature prediction, unvalidated (though plausible) scalability claims, limited methodological novelty beyond combination of existing methods.

Formatting concerns

N/A

4 comments
Authors · RebuttalOpenReview ↗
Rebuttal

Response to Reviewer q6HF

We thank the reviewer for a detailed, actionable review. We ran leave-one-region-out transfer, a capacity-matched LSTM, and the proposed clipping/signed-Q fixes. Two results correct the paper: size does not explain LSTM accuracy, and simple projections repair the original feasibility metrics.

1. Transfer and scalability (W1–W2, Limitation 2)

We trained on two regions and evaluated zero-shot on the third; its climate-zone and ReEDS-area categories were absent from training. Entries are in-distribution multi-region → leave-one-region-out:

Held-out TairT_{air} RMSE [°C] QheatQ_{heat} MAPE [%] QcoolQ_{cool} MAPE [%]
CA (TX+NY) 2.07 → 2.19 72.8 → 75.9 58.9 → 68.2
NY (CA+TX) 1.81 → 1.56 40.7 → 47.5 57.0 → 64.4
TX (CA+NY) 1.62 → 1.59 61.0 → 71.3 41.3 → 45.9

TairT_{air} changes by at most +0.12 °C and improves in two regions; load MAPE worsens by 3–10 pp. Thus envelope dynamics transfer better than load magnitude, which also depends on regional HVAC sizing and schedules. We will add this table and narrow the introduction to this measured result. These MAPEs use the per-region masked definition, not Table 2's aggregate definition; only within-table changes should be compared. LOSO covers NeuralBES only; without matched baseline runs, we do not claim black boxes transfer worse.

Scalability was asserted, not benchmarked. The supported claim is input-side: EnergyPlus needs a detailed per-building specification and identified RC models need per-building calibration; NeuralBES conditions one population model on coarse metadata. We will state an input-cost/fidelity trade-off, not measured scaling.

2. Capacity-matched LSTM (W5, Limitation 1)

We ran a 0.98 M-parameter LSTM (hidden 144, 2 layers) through the same 3-seed annual-rollout harness:

Model Params TairT_{air} RMSE [°C] QheatQ_{heat}/QcoolQ_{cool} MAPE [%] Mode excl./Bounds [%]
NeuralBES 1.0 M 2.79±0.03 41.5±4.3 / 41.3±0.4 100.0±0.0 / 99.7±0.1
LSTM (published) 36.6 M 1.48±0.01 38.5±0.1 / 37.6±1.7 36.9±18.0 / 63.1±18.0
LSTM (matched) 0.98 M 1.30±0.10 32.6±2.4 / 30.9±4.9 32.4±9.6 / 67.2±9.4

The matched LSTM improves on the larger LSTM and beats NeuralBES on every error metric. Our capacity explanation was wrong; we will delete the inductive-bias and 36×-size arguments. Reducing capacity improves accuracy but not mode exclusivity or bounds adherence.

3. LSTM clipping and signed QQ (LSTM Baseline Feasibility)

On the annual 35,040-step multi-region rollout of Table 2, we applied the reviewer's post-hoc fixes to the published checkpoints:

Variant Mode excl. [%] Bounds [%] QheatQ_{heat}/QcoolQ_{cool} MAPE [%] TairT_{air} RMSE [°C]
NeuralBES 100.0 99.6 36.5 / 41.8 2.756
LSTM, published 17.0 83.0 38.5 / 35.7 1.474
+ clip Q≥0Q\ge0 17.0 99.0 38.3 / 35.7 1.474
+ single signed QQ 100.0 99.0 37.7 / 36.7 1.474
+ signed QQ + TT clip 100.0 100.0 37.7 / 36.7 1.538

The reviewer is right: these projections repair mode exclusivity and bounds with little accuracy cost. We retract the unique-frontier claim and treat these metrics as necessary but easy-to-enforce. The same holds on the weekly rollout, so the conclusion is not horizon-specific.

The residual distinction is temporal: clipping and signed-QQ act independently at each timestep, enforcing channel relations and boxes but nothing about time. For QheatQ_{heat}, off-state fidelity is 94.8% for NeuralBES, 90.5% for the patched 36.6 M LSTM, and 92.1% for the patched 0.98 M LSTM; leakage integrates to 3.7%, 6.2%, and 4.6% of true annual heating. Because clipping makes every leak nonnegative, it cannot average out: the patched LSTM's 6.2% is systematic upward bias in annual energy/cost integrals and can contaminate peak-demand estimates. NeuralBES also matches the true heating-off duty cycle (76.0% predicted vs. 75.1% truth), whereas both LSTMs undershoot by 5–6 pp. We therefore narrow the claim to off-state and duty-cycle fidelity, not pointwise sign or box constraints.

4. RC topology, encoder sharing, and physics-aware baselines (W3–W4)

Topology/RC baseline. Our terminology is inconsistent: Eqs. 1–2 contain two capacitances and three conductances, although parts of the paper call the model “2R2C.” RC Grey-Box and NeuralBES use the same node/conductance topology, parameter scales, and near-equal budgets. They are separately trained; RC uses fixed COPs and a fixed setpoint band, while NeuralBES adds learned internal gains, wind-dependent infiltration, COP derating, schedule-aware setpoints, and predictor–corrector control. PI-Roformer is intentionally different: its physics term is a soft residual on the quasi-steady (dTmass/dt≈0dT_{mass}/dt\approx0) one-air-node reduction of the same network, so it regularizes a black-box trunk rather than performing an RC rollout. We will report node/conductance counts explicitly and use “3R2C” consistently for the rollout models.

Static encoder. “Shared” means the same encoder architecture/input interface, not shared weights; each model trains its own end-to-end. Black-box baselines receive static features through FiLM/embeddings, never RC coefficients; only NeuralBES and RC predict physical parameters. ResStock has no ground-truth RC values, so we will state that they are end-task identified and report learned CC/UAUA ranges.

Physics-aware comparison. We will first correct Table 1's “Parameters per building” and “Cross-building eval” rows method-by-method; the current entries incorrectly collapse distinct training and evaluation settings. The cited PINN/PCNN/neural-ODE implementations identify one building/zone model at a time and provide no metadata-conditioned population encoder, so stock-scale use requires per-building fitting or a new population extension—the cost NeuralBES removes. RC Grey-Box lifts the identified-RC family to a shared population encoder, so this head-to-head exists; PI-Roformer isolates a soft heat-balance residual on a black-box trunk. We will foreground both and acknowledge that neither is a named external reimplementation.

5. Why loads matter; thermostat scope (W6)

On TairT_{air} alone, the matched LSTM is better (1.30 vs. 2.79 °C RMSE), and we do not contest that. Our remaining claim concerns tasks that require the load shape itself. QheatQ_{heat}/QcoolQ_{cool} are outputs: tariffs, demand response, capacity planning, grid load shapes, and retrofit ROI integrate their timing and magnitude. They are also harder than TairT_{air} because they contain long exact-zero intervals and discrete thermostat events. On truly-off timesteps of the annual rollout, NeuralBES's fidelity is 94.8%/92.9% for heating/cooling, versus 89.2%/77.0% for LSTM and 66.2%/86.5% for Roformer. Roformer is the clearest horizon effect: its heating off-state fidelity falls from 90.9% on the weekly rollout to 66.2% on the annual one, the same collapse its MAPE shows. We will add this diagnostic and motivate load prediction.

We will list the thermostat as a scope limitation. The capacity-or-idle branch matches most ResStock samples and EnergyPlus's residential zone predictor; a smooth relaxation is less physical because it emits fractional load while the compressor is off. Modulating HVAC, MPC, hysteresis, and sub-15-minute cycling are out of scope; modulation only requires replacing this branch, not the RC equations or scan.

As the reviewer notes, Figure 3 ground truth can also show simultaneous heating/cooling from within-bin mode changes and multi-system/defrost operation. Thus 100% exclusivity is not “more physical” than the data; we will state this caveat.

6. Figures 2 and 3 (W7)

Figure 2. We agree the grouping is unsupported: NeuralBES's mean slope (0.450) is closer to LSTM (0.478) than RC (0.104), and our “>2 °C” criterion would also flag NeuralBES. A population-mean slope cannot establish a unique correct response for a heterogeneous stock, so we will remove the categorical labels rather than substitute another grouping. The unambiguous findings are PatchTST's zero response and RC's much smaller response.

Figure 3. We agree that LSTM tracks fall comparably and that our sentence overgeneralized. In the shown summer panel, both truth and NeuralBES remain near the cooling setpoint, so the near-static trace alone is not evidence of failure or success. Yet in Fig. 7 only NeuralBES reproduces the summer diurnal swing; Roformer and PI-Roformer stay near 21 °C in fall against truth reaching ~26 °C. We will report mean ∣ΔTair∣|\Delta T_{air}| per 15 min: 0.045 °C (truth), 0.037 (LSTM), 0.041 (Roformer), and 0.025 (NeuralBES), explicitly acknowledging NeuralBES's under-ramping.

7. Protocol and minor clarifications

Training windows. Models are trained, not fine-tuned, on 672-step windows tiled across each building's full year. All timesteps are used, and Smooth-L1 is averaged over every predicted step; there is no test-time tuning. We also found unequal overlap (0.5 for NeuralBES/PatchTST/DLinear, 0 for LSTM/Roformer/RC) and will equalize it.

Exogenous inputs. All models and the emulated simulator receive the same ground-truth weather, schedules, and occupancy. Forecasting these inputs is outside scope and will be listed as a limitation.

Notation. We will add a symbol table, define every variable at first use, standardize on TairT_{air}, and clarify that −ϵ-\epsilon is a numerical non-negativity tolerance, not a typo.

In summary, we retract the capacity and unique-frontier claims, correct both figure interpretations, and narrow the contribution to a physics-structured simulator whose pointwise constraints can be copied by post-processing but whose off-state and duty-cycle behavior remain better aligned with the underlying dynamics.

Reviewer q6HF · CommentOpenReview ↗

Thanks for the extra experiments and thoughtful rebuttal to my review. Responses below:

1. Transfer and scalability (W1–W2, Limitation 2)

Got it, thanks for the updated experiments. LGTM regarding transferability. I understand your input-side claim and I do agree with you there (and also suspect there are practical scalability benefits) but I do think regarding scalability, it would make the paper stronger if it is explicitly shown, since it is indeed used as a major motivation. If there is anything reasonable you could still add during the rebuttal period, I would encourage you to explore this further.

2. Capacity-matched LSTM (W5, Limitation 1)

Thank you for investigating this and presenting updated results / claims. This is important for transparency.

3. LSTM clipping and signed (LSTM Baseline Feasibility)

Ack.

4. RC topology, encoder sharing, and physics-aware baselines (W3–W4)

Topology/RC baseline. Thank you for correcting the part about the 3R2C model. This is a very vital detail for comparability.

However, it is still unclear to me how you chose/configured the Gray-box RC model? You say you use the same static encoder architecture, and the same node/conductance topology, but internal gains does not seem to be learned in the gray-box model (lines 248-252), so what did you use here instead (since you also said yourself that ResStock does not always have ground-truth). I don't mean to be tedious, but I do not think you adequately explain how this model was developed, how it differs, or if it is sophisticated or commonly used, which is quite important in determining both the fairness of baseline as well as the novelty of NeuralBES. Also, you explain in lines 248-252 which parameters the baseline learns, and what NeuralBES learns on top, but there is not an adequate discussion or clarity (in my opinion) of if these extra learned parameters are novel, relative to previous studies. For example, until the log-space scan and predictor–corrector control, NeuralBES is essentially a formulation of a gray-box model, where you choose these certain parameters to learn.

So concretely: why is this subset of learned parameters the best choice for a baseline / state-of-the-art in gray-box RC models, and how novel are those extra learned parameters you added?

Static encoder. Got it, thanks. Yes, it is important to clarify this.

Physics-aware comparison. Ack.

5. Why loads matter; thermostat scope (W6)

Sounds good regarding the thermostat limitation and the caveat with Fig 3.

Also thanks for clarifying about the relevance of the Qheat and Qcool outputs, because I now better understand what you are targeting. I would recommend emphasizing this point more about why Q is important, because it helps better-position your intended contribution, which gets diluted by the poorer T predictions.

6. Figures 2 and 3 (W7)

Figure 2. Ack.

Figure 3. To be honest, I am not sure how much I agree with these statements since it is sometimes difficult to see the NeuralBES line in Figure 7, but if your point is that the temperature envelope / range of NeuralBES is closer to the actual than the others, then yes, the ∣ΔTair∣|\Delta T_{air}| would achieve this as well.

7. Protocol and minor clarifications

Training windows. Ack.

Exogenous inputs. Ack. FWIW, this is simply important for transparency and applicability -- does not take much away from your study in my opinion.

Notation. Ack. If you're running out of space, Appendix is also fine, but just as long as a reader can find it.


Thanks to the authors again for their thoughtful responses and engagement to address my feedback -- much appreciated. Your provided updates and clarifications surely improve the quality and scientific integrity of the paper. I unfortunately still have doubts about the novelty/level of contribution, as well as the baselines (see (4)), so I will await your response before considering my score change.

Authors · CommentOpenReview ↗

Thank you for asking us to sharpen the novelty claim. We agree that NeuralBES belongs to the broad family of grey-box models, but respectfully argue that it is not a conventional grey-box model with a larger hand-selected parameter set. Our contribution is not a new resistance, capacitance, infiltration law, or COP curve in isolation; it is the identification and simulation regime that unifies these established components.

First, NeuralBES replaces per-building identification with population-amortized identification. Conventional grey-box methods estimate a parameter vector θb\theta_b from measurements collected from the same building bb, generally including its observed indoor temperature and HVAC heat input. A new building therefore requires another identification or calibration run. NeuralBES instead learns a shared map gϕ(sb)↦θbg_\phi(s_b) \mapsto \theta_b from static descriptors sbs_b to building-specific thermal, infiltration, internal-gain, and equipment coefficients. At inference, an unseen building receives these coefficients without fitting to any portion of its target trajectory. Our leave-one-region-out results further show that this map can be applied when the entire evaluation region is absent from training. To our knowledge, amortizing this metadata-to-physics identification across a heterogeneous building population, rather than fitting each building independently, is novel.

Second, NeuralBES provides an end-to-end differentiable implementation of a control-coupled RC model. Conventional RC temperature models generally treat HVAC heat as an observed forcing. NeuralBES instead closes the thermostat–temperature loop through a capacity-constrained predictor–corrector, making QheatQ_{\mathrm{heat}}, QcoolQ_{\mathrm{cool}}, and TairT_{\mathrm{air}} self-consistent outputs. We combine this controller with a log-space scan that preserves gradients across the complete 672-step training window, whereas our sequential RC implementation detaches its state every 48 steps. The scan and predictor–corrector each have precedent; the contribution is their integration with population-conditioned coefficients into a jointly trained load-and-temperature simulator.

The novelty boundary for the individual components is therefore:

Component Prior status NeuralBES contribution
Internal gains, wind infiltration, and COP derating Established BEM terms Building-conditioned effective coefficients learned jointly without coefficient labels
RC coefficients and equipment capacities Established physical parameters Predicted zero-shot from metadata instead of fitted on the target building
Scheduled setpoints Established control inputs Incorporated into the endogenous load–temperature loop
Log-space scan and predictor–corrector Established numerical ideas Combined into a differentiable, control-coupled RC rollout

Why does the RC baseline stop at its chosen parameter set? There is no universally optimal RC order; the grey-box literature selects model complexity according to the application and information available. Nevertheless, our stopping point is principled. A conventional per-building fit must restrict its free coefficients to those that can be reliably estimated from one building's limited trajectory, which is precisely why that literature uses model-order selection. Our reference therefore predicts every resistance and capacitance in the same 3R2C topology as NeuralBES, plus solar aperture and heating/cooling capacities required for the three benchmark outputs. It also includes internal gains through one population-level linear map from the 17 schedule channels.

The population objective can support additional building-specific degrees of freedom because their metadata-to-parameter map is constrained jointly across thousands of buildings rather than estimated independently for each building. We do not claim that the resulting coefficients are uniquely identifiable; they are end-task-identified effective parameters. This distinction is central: the additional terms are not new physics, but estimating and coupling them in this population-amortized regime is part of the contribution.

Thus, NeuralBES's novelty is the unification of population-level zero-shot identification, endogenous load–temperature coupling, and differentiable long-horizon simulation. To our knowledge, the cited grey-box, PCNN, PINN, and neural-ODE studies do not demonstrate this combination in a single metadata-to-physics model evaluated on unseen buildings and regions. We thank the reviewer for prompting us to make this boundary explicit and will revise the paper accordingly.

Reviewer q6HF · CommentOpenReview ↗

Novelty

While I agree that learning a shared map based on a several buildings is helpful, I think the claim that amortizing metadata-to-physics identification across a heterogeneous building population is novel is overstated. For example, the Bayesian hierarchical calibration study from Kristensen et al. 2018 [1] already assigns physical parameters to unseen buildings from metadata alone, learned from a heterogeneous population, with no measurements on the target (and FWIW, archetype-based UBEM such as TABULA and ResStock essentially use metadata to sample/map to building physical characteristics to do the modeling in the first place...). Furthermore, the proposed shared map is a regression whose prediction quality relies heavily on having many building types to train on (ex. the same architecture trained on a single building would be structurally identical but would fail to transfer). Training across a population therefore does not introduce a new inferential mechanism, but rather supplies enough coverage of descriptor space to make an otherwise ill-posed regression identifiable. So it seems like a data-coverage argument, not a methodological one.

As I see it, the authors' delta relative to this line of work is (i) conditioning on a richer continuous descriptor vector rather than a discrete archetype class, and (ii) fitting the map end-to-end through the RC dynamics and corrective steps. Both are reasonable but should be claimed at that scale, with the above and others positioned as prior related works.

As an aside, regarding the point about HVAC heat, off the top of my head I do not know any studies that do this so cannot make direct claims about its novelty, so will not push back here. However, I would urge the authors to confirm with a thorough literature review that this is indeed correct.

[1] Kristensen, Martin Heine, Rasmus Elbæk Hedegaard, and Steffen Petersen. "Hierarchical calibration of archetypes for urban building energy modeling." Energy and Buildings 175 (2018): 219-234.

RC Baseline

Yes, I understand that there is no universal gray-box baseline, which is why it is important that the baseline here is calibrated in a way that shows the benefits of the authors' novel additions, rather than having this conflated with simply having more free parameters. For me, it suffices so long as the authors (1) justify that it is indeed a reasonable and fair comparison and not a hand-selected set of parameters; (2) clearly outline in the manuscript the differences between the baseline and the 3R2C part of NeuralBES. It seems from the last sentence of the authors' response that they are in agreement to do this.


Ultimately, my feelings about novelty remain unchanged, but I am relatively satisfied with the answer about the RC baseline (so long as it is made explicit in the manuscript how this differs if at all from the RC component of NeuralBES in the end). I think the paper's contribution lies less in the novelty of its methodology but rather in the combination of these established components in a way that makes sense for the application of Building Energy Modeling, and the results seem to at least be effective and more physically consistent in the prediction of Q (but not so much for T), which is relevant for certain downstream tasks as the users describe. Furthermore, the authors addressed many of my concerns, clarified several points, and corrected/updated experiments and the paper's claims.

I have raised my rating to a 4. Despite its weaknesses, this paper indeed has a relevant use case, some interesting ideas, a well-tailored methodology, promising results, and transparency of limitations that could be valuable for the broader community, particularly in its BEM application domain.

Existing weaknesses include: Limited / no benefit for temperature prediction, unvalidated (though plausible) scalability claims, limited methodological novelty beyond combination of existing methods.

Reviewer 6qt2OpenReview ↗
Rating
5/6
Confidence
2/5
Quality
4/4
Clarity
3/4
Significance
3/4
Originality
4/4
Contribution type
use_inspired
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper develops a scalable modeling framework for building HVAC energy usage which is typically requires either detailed information about the structure amd calibration or is predicted with a black box model. The authors develop a method to use readily available building metadata to create an interpretable model with lower compute and memory cost.

Strengths and weaknesses

Strengths- The use case of simulating building energy use is known and valuable. The design appears to be well matched to the use case with the ability to accurately simulate buildings with limited data and producing an interpretable result. The approach appears to be different for prior work and close gaps in prior models. The results section explains a number of ways that this approach achieves realistic patterns.

Weaknesses- The current writing does a good job of highlighting the differences between NeuralBES and baselines including specific failure modes and limitations of prior work like the mode exclusivity, ability to produce “discrete spike events” and how it avoids the way prior works produce outputs that are “statistically defensible but physically nonsensical.” What I don’t fully understand or have to guess at is how this connects back to the original objective of informing grid planners, utility analysts etc mentioned in the introduction. The ability to get good results without detailed individual building measurements is self explanatory, but right now the reader is left to infer that being better at detecting spiking events is likely useful because it could help show peak demand for capacity planning etc. Making these connections more explicit would be very helpful to understand the significance of this work to the intended users. Similarly, interpretability is a key theme throughout the paper starting in Table 1 which mentions the need to expose terms like C, U A. What aspects of interpretability are important to these users and specifically for simulating populations of buildings as mentioned in the introduction? Is a black box model that produces low MAPE good enough for this? In Table 2 the LSTM does a few percent better in terms of overall MAPE and RMSE, when is this not useful for analyzing aggregate buildings? Also how infeasible is it to run current models at scale and what does that mean (1k buildings, 100k, 1M)? In summary, to a reader outside the domain it seems like the model does what it is designed for but it’s hard to fully understand why these contributions are significant for the intended use.

Clarity- Section 3 contains sufficient details about the thermal model and is explained relative to the ML problem. However, this only comes up later in the paper and RC parameters are mentioned in the intro as early as line 40. It would be helpful to give some (brief) intuition about this in the main text, especially in the introduction for readability and explicitly refer the reader to Appendix A for definitions. Similarly when reading Table 1 I have no idea what C, U and A are. Also maybe I missed this but does this work assume all buildings are at a standard set point for temperature? Just thinking about variation in individual homes etc and things like smart thermostats that do scheduling.

Questions

Why are these results significant to the intended users and domain? See notes above

Limitations

Yes, although the note about how this work doesn't model hot water systems in the limitations section made me realize that maybe this

Formatting concerns

None

2 comments
Authors · RebuttalOpenReview ↗
Rebuttal

Response to Reviewer 6qt2

We thank the reviewer for identifying that the paper does not connect its diagnostics clearly enough to the intended users.

Significance to grid and utility applications

We agree that a lower-MAPE black-box model can be preferable when the task only requires point predictions. In fact, our new capacity-matched experiment strengthens this point: a 0.98 M-parameter LSTM outperforms NeuralBES on all three raw-error metrics. We will therefore remove the parameter-count explanation and the claim that NeuralBES uniquely occupies an accuracy/validity frontier.

The remaining distinction is narrower and temporal. Grid load shapes, peak-capacity studies, tariff/demand-response analyses, and retrofit ROI depend on the timing and integral of QheatQ_{heat}/QcoolQ_{cool}, not only average point error. Post-processing does not remove off-state leakage: heating off-state fidelity is 94.8% for NeuralBES versus 90.5%/92.1% for the patched large/matched LSTMs, with leakage equal to 3.7% versus 6.2%/4.6% of true annual heating. We will make this application mapping explicit and will not characterize a low-error black box as unusable.

The interpretable quantities also need clearer motivation. CC describes thermal storage/inertia, while UAUA describes heat-loss conductance; at stock scale these support plausibility checks, building stratification, and inspection of retrofit or weather counterfactuals. However, ResStock provides no ground-truth RC coefficients, so these are end-task-identified parameters rather than verified physical measurements. We will state this limitation and report their learned ranges.

Scalability, clarity, and thermostat scope

The reviewer is right to ask what “scale” means. We did not benchmark 1k, 100k, or 1M buildings, so we will not claim measured scalability. The supported claim is input-side: EnergyPlus requires detailed per-building specifications and identified RC models require per-building calibration, whereas NeuralBES applies one population model to coarse metadata. We will present this as an input-cost/fidelity trade-off.

We will add brief RC intuition in the introduction, define CC, UU, AA, and UAUA before Table 1, add a symbol table, and point explicitly to Appendix A. Buildings do not share one standard setpoint: NeuralBES receives building- and time-varying heating/cooling setpoint schedules. The present capacity-or-idle controller represents single-stage equipment; modulating HVAC, MPC, hysteresis, and sub-15-minute cycling will be listed as out of scope.

Reviewer 6qt2 · CommentOpenReview ↗

Thank you for the response, these clarifications on the technical details are helpful. The response also acknowledges my comment about not connecting results to the intended users but doesn't include detail on how or where this will be addressed. Both as a paper in the use-inspired track and to help this work appeal to a broad audience I would like to see some writing change to address this with some explicit application examples (Ex: being better at detecting spiking events is likely useful because it could help show peak demand for capacity planning etc). A good place for this could be either the end of the introduction or a discussion section explaining the implications of the results.

Comments on the paper

1 comment
Area Chair xYKH · CommentOpenReview ↗

End of discussion period approaching

Dear reviewers, there's about 1 day left in the discussion period and the authors have posted their rebuttal. If you have any remaining questions or topics you'd want to discuss with the authors, please do this as soon as possible.