Revitalizing Medical Time Series with Vision-Informed Retrieval: A Vision-Language Perspective
Guoqi Yu, Juncheng Wang, Shujun Wang
NeurIPS 2026
TL;DR. We leverage VLM waveform priors to retrieve morphology-relevant numerical tokens for improved medical time series classification.
Abstract. Medical time series (MedTS) underpin many clinical classification tasks, yet existing methods usually represent them only as numerical sequences and underuse the morphology that is explicit in waveform inspection. To bridge this gap, we introduce Vision-Informed Retrieval (ViRe), which uses a frozen VLM-derived waveform representation as a morphology-aware Query to guide retrieval from raw numerical MedTS features. Specifically, a Vision Query is extracted using pre-trained vision-language models (VLMs) to obtain morphology-aware priors from waveform plots. A tailored attention-based cross-modal retrieval mechanism then uses the Vision Query to select morphology-relevant temporal and channel evidence from the numerical representation. ViRe demonstrates strong effectiveness against ten established baselines, yielding an overall 6.42% relative improvement over the previous state of the art across six public benchmarks. Code, training scripts, and reproducibility materials are publicly available in the Github Repo.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:44 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
The paper proposes Vision-Informed Retrieval (ViRe), which leverages a frozen vision-language model to extract morphology-aware visual priors from waveform images and integrates these priors into time-series representations through a cross-attention retrieval mechanism. The experimental results on six public ECG/EEG benchmarks demonstrate consistent improvements over existing methods. The reviewers agree that this paper addresses an important and clinically relevant problem in medical time-series analysis by incorporating visual waveform information into numerical representations. The proposed framework is technically reasonable and empirically well evaluated across multiple public datasets with ablation studies.
However, several important questions remain before the paper can be considered for acceptance. The rebuttal should primarily focus on the following issues:
- Clarification of the paper’s core novelty and positioning with respect to prior work. Multiple reviewers questioned how ViRe differs conceptually from existing vision-based time-series modeling approaches (e.g., ViTime). The rebuttal should clearly distinguish the novel contribution of this work, including whether the contribution primarily lies in the use of CLIP-derived visual priors, the retrieval mechanism, the medical application, or another aspect.
- Evidence supporting the claimed semantic or clinician-aligned representation. The current empirical results convincingly demonstrate predictive utility, but reviewers found the evidence less convincing for the stronger claims regarding semantic, human-aligned, or clinically grounded representations.
- Additional empirical clarification. Several reviewers requested stronger empirical validation, including statistical significance testing, comparison against stronger and more recent baselines where appropriate, and further analysis of which clinical conditions or waveform characteristics benefit most from the proposed visual priors.
- Improved clarity of the experimental design and evaluation scope. Reviewers requested a clearer description of the experimental setting and evaluation protocol. Please clarify the intended scope of the proposed framework and discuss whether it is expected to generalize to other medical time-series tasks.
Final justification
I have read the authors’ response in full and considered the complete post-rebuttal discussion and reviewer updates. My initial meta-review leaned toward rejection because the original submission did not sufficiently clarify its novelty relative to prior visual time-series methods, substantiate its stronger semantic and clinician-alignment claims, establish the statistical reliability of its gains, or clearly delimit its experimental scope. The rebuttal provides substantial new evidence on all four issues and appropriately narrows the interpretation of the method. On balance, this changes my recommendation to acceptance.
The reviewers’ post-rebuttal assessments were mixed but leaned positive. One reviewer stated that the concerns regarding statistical reliability, diagnosis-level behavior, and computational cost were well addressed and maintained a Borderline Accept rating. A second reviewer increased the rating to Borderline Accept after the authors added stronger recent baselines, irregular forecasting and classification experiments, and a clearer explanation of the visual pathway. The remaining reviewer maintained a Borderline Reject rating: they acknowledged the improved positioning and stronger evidence that the frozen CLIP representation contains morphology-related structure, but remained concerned that the new analyses validate the visual prior more directly than they validate concept preservation throughout the retrieval mechanism, and that the concept-level evidence is primarily ECG-specific. I agree that these are genuine limitations, but I do not find them sufficient to outweigh the paper’s methodological and empirical contribution under its revised, narrower claims.
Overall, ViRe presents a well-motivated vision-informed retrieval mechanism, broad evaluation across medical time-series datasets, extensive ablations, and substantial new statistical and concept-level analyses. The rebuttal resolves the principal issues underlying my initial recommendation and narrows the claims where the evidence remains incomplete. I therefore recommend acceptance as a poster.
Finally, the PhysioNet reference was flagged. The underlying Circulation article is real, but the submission incorrectly lists “PhysioToolkit PhysioBank” as the author and truncates the title, omitting the actual author list. The correct reference should be "Goldberger AL, Amaral LA, Glass L, Hausdorff JM, Ivanov PC, Mark RG, Mietus JE, Moody GB, Peng CK, Stanley HE. PhysioBank, PhysioToolkit, and PhysioNet: components of a new research resource for complex physiologic signals. Circulation. 2000 Jun 13;101(23):E215-20. doi: 10.1161/01.cir.101.23.e215. PMID: 10851218." The authors must correct the citation metadata in the final version.
Read meta-review
Meta-review
The paper proposes Vision-Informed Retrieval (ViRe), which leverages a frozen vision-language model to extract morphology-aware visual priors from waveform images and integrates these priors into time-series representations through a cross-attention retrieval mechanism. The experimental results on six public ECG/EEG benchmarks demonstrate consistent improvements over existing methods. The reviewers agree that this paper addresses an important and clinically relevant problem in medical time-series analysis by incorporating visual waveform information into numerical representations. The proposed framework is technically reasonable and empirically well evaluated across multiple public datasets with ablation studies.
However, several important questions remain before the paper can be considered for acceptance. The rebuttal should primarily focus on the following issues:
- Clarification of the paper’s core novelty and positioning with respect to prior work. Multiple reviewers questioned how ViRe differs conceptually from existing vision-based time-series modeling approaches (e.g., ViTime). The rebuttal should clearly distinguish the novel contribution of this work, including whether the contribution primarily lies in the use of CLIP-derived visual priors, the retrieval mechanism, the medical application, or another aspect.
- Evidence supporting the claimed semantic or clinician-aligned representation. The current empirical results convincingly demonstrate predictive utility, but reviewers found the evidence less convincing for the stronger claims regarding semantic, human-aligned, or clinically grounded representations.
- Additional empirical clarification. Several reviewers requested stronger empirical validation, including statistical significance testing, comparison against stronger and more recent baselines where appropriate, and further analysis of which clinical conditions or waveform characteristics benefit most from the proposed visual priors.
- Improved clarity of the experimental design and evaluation scope. Reviewers requested a clearer description of the experimental setting and evaluation protocol. Please clarify the intended scope of the proposed framework and discuss whether it is expected to generalize to other medical time-series tasks.
Final justification
I have read the authors’ response in full and considered the complete post-rebuttal discussion and reviewer updates. My initial meta-review leaned toward rejection because the original submission did not sufficiently clarify its novelty relative to prior visual time-series methods, substantiate its stronger semantic and clinician-alignment claims, establish the statistical reliability of its gains, or clearly delimit its experimental scope. The rebuttal provides substantial new evidence on all four issues and appropriately narrows the interpretation of the method. On balance, this changes my recommendation to acceptance.
The reviewers’ post-rebuttal assessments were mixed but leaned positive. One reviewer stated that the concerns regarding statistical reliability, diagnosis-level behavior, and computational cost were well addressed and maintained a Borderline Accept rating. A second reviewer increased the rating to Borderline Accept after the authors added stronger recent baselines, irregular forecasting and classification experiments, and a clearer explanation of the visual pathway. The remaining reviewer maintained a Borderline Reject rating: they acknowledged the improved positioning and stronger evidence that the frozen CLIP representation contains morphology-related structure, but remained concerned that the new analyses validate the visual prior more directly than they validate concept preservation throughout the retrieval mechanism, and that the concept-level evidence is primarily ECG-specific. I agree that these are genuine limitations, but I do not find them sufficient to outweigh the paper’s methodological and empirical contribution under its revised, narrower claims.
Overall, ViRe presents a well-motivated vision-informed retrieval mechanism, broad evaluation across medical time-series datasets, extensive ablations, and substantial new statistical and concept-level analyses. The rebuttal resolves the principal issues underlying my initial recommendation and narrows the claims where the evidence remains incomplete. I therefore recommend acceptance as a poster.
Finally, the PhysioNet reference was flagged. The underlying Circulation article is real, but the submission incorrectly lists “PhysioToolkit PhysioBank” as the author and truncates the title, omitting the actual author list. The correct reference should be "Goldberger AL, Amaral LA, Glass L, Hausdorff JM, Ivanov PC, Mark RG, Mietus JE, Moody GB, Peng CK, Stanley HE. PhysioBank, PhysioToolkit, and PhysioNet: components of a new research resource for complex physiologic signals. Circulation. 2000 Jun 13;101(23):E215-20. doi: 10.1161/01.cir.101.23.e215. PMID: 10851218." The authors must correct the citation metadata in the final version.
2 comments
Response to the Area Chair (Part-1)
We thank the Area Chair for the careful synthesis and for recognizing the clinical relevance of the problem, the technical soundness of ViRe, the consistent gain across six MedTS benchmarks, and the comprehensive ablation studies. We address the four remaining points directly below.
1. Core novelty and positioning
ViRe’s core contribution is an asymmetric vision–numerical interaction: a morphology-aware representation extracted by CLIP [1] acts exclusively as a global Vision Query, while the original temporal and channel representations remain the Keys and Values in two cross-attention retrieval paths.
This role of vision distinguishes ViRe from prior vision-based time-series approaches. ViTime [2] performs forecasting primarily in an image-based representation space, whereas Time-VLM [3] fuses visual and textual embeddings with temporal features. ViRe instead uses the visual prior to determine which temporal and channel evidence should be retrieved from the original numerical representation.
The principal methodological novelty of ViRe is therefore a VLM-derived global Vision Query for dual retrieval from numerical MedTS representations.
2. Evidence for semantic and clinician-relevant representation
The original experiments establish the predictive utility of the Vision Query. The added analyses directly evaluate whether this representation preserves human-observable morphology and clinically meaningful waveform attributes.
Using 662,400 quality-controlled ECGs from 154,802 patients in MEETI [4], with an identically frozen random encoder as control, we conduct four complementary tests. (i) Concept decoding shows that all 22 supported morphology and report-linked attributes are more recoverable from CLIP; (ii) zero-shot text alignment improves across all 12 supported attribute directions; (iii) same-patient analyses show that representation changes follow HR, PR, QRS, QT, and QTc changes; and (iv) raw-space retrieval yields stronger attribute consistency across all 21 supported waveform attributes .
These analyses provide direct evidence that the Vision Query exhibits concept-level structure aligned with human-observable morphology and clinically meaningful ECG attributes.
3. Additional empirical validation
The added evidence establishes that ViRe’s improvements are statistically significant, stable across subject partitions, competitive against recent task-specific baselines, and broadly distributed across diagnoses, with the strongest gains on morphology-sensitive conditions.
Statistical reliability. Against Medformer [5], ViRe wins all 5/5 matched-seed comparisons and all 7/7 pre-specified subject-disjoint PTB-XL [6] folds for both all-13 diagnosis macro F1 and official five-superclass macro F1. The corresponding confidence intervals exclude zero, while paired -tests and Wilcoxon signed-rank tests confirm statistical significance. Consistent gains are also observed across ten matched subject-disjoint splits on APAVA and PTB.
Stronger recent baselines. Under established irregular forecasting and classification protocols, ViRe is compared with Hi-Patch [7], MTM [8], STraTS [9], t-PatchGNN [10], and GRU-D [11], and ranks first on every reported metric.
Conditions and waveform characteristics. On the locked PTB-XL [6] test set, ViRe improves 11/13 diagnoses. The largest gains occur for HYP and LVH, both remaining significant after Holm correction, while positive improvements also span infarction, ST-T change, ischemia, and atrial fibrillation.
The diagnosis-level and attribute-level results jointly indicate that ViRe is particularly informative for morphology-related patterns.
- Rating
- 3/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 2/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper proposes ViRe, a framework for medical time-series classification that combines numerical MedTS modeling with a visual waveform branch derived from a frozen CLIP vision encoder, using a global Vision Query and cross-attention retrieval to inject morphology-aware priors into numerical representations. The paper reports consistent gains over strong MedTS baselines across six public benchmarks and provides supporting ablations on retrieval queries, vision backbones, and feature-space analyses.
Strengths and weaknesses
Strengths The paper addresses a clinically motivated problem setting. Its motivation is plausible: many existing medical time-series models operate primarily on numerical sequences, whereas clinical interpretation of EEG/ECG often relies on visually recognizable waveform morphology. This makes the paper potentially significant as a use-inspired contribution. The proposed method is also relatively clear and easy to follow. ViRe extracts temporal and channel embeddings from the raw MedTS signal, renders the same signal as a waveform image, obtains a visual feature using a frozen CLIP vision encoder, and uses this feature as a shared query to retrieve relevant numerical information through cross-attention. The empirical evaluation covers multiple EEG and ECG datasets under subject-independent splits, and the ablation studies help isolate the effects of the Vision Query, fusion strategy, and vision backbone. Weaknesses
- Originality and positioning relative to prior work. The paper should more clearly position its contribution relative to prior vision-based time-series modeling work such as ViTime [1], which already advocates transforming numerical time series into visual representations and learning in image space as an alternative to purely numerical fitting. As a Use-Inspired submission, the paper has a meaningful and well-motivated clinical use case, and the method is reasonably matched to that use case through waveform-aware modeling and subject-independent evaluation. My concern is therefore not that the paper lacks value as an application-driven contribution, but that its novelty claims should be positioned more carefully relative to prior vision-based time-series modeling work such as ViTime. Ref: [1] ViTime: Foundation Model for Time Series Forecasting Powered by Vision Intelligence, 2025, Transactions on Machine Learning Research
- Unclear meaning of semantic or human-aligned concepts. The semantic interpretation of the visual branch is currently underspecified. The paper uses phrases such as “human-describable concepts,” “semantically structured summary,” and “clinically grounded guidance,” and suggests that waveform embeddings encode morphology-aware priors such as trends, spikes, and fluctuations. However, it is unclear what level of “concept” is intended: generic visual patterns learned by CLIP, clinically meaningful morphology terms, or diagnosis-relevant intermediate attributes. This affects the clarity of the paper’s central motivation.
- Evidence supports utility more strongly than concept-level alignment. The current experiments provide stronger evidence that CLIP supplies a useful and structured auxiliary visual prior than that the learned representation is aligned with explicit human-describable or clinically meaningful concepts. The main support comes from predictive improvements, query-replacement ablations, backbone ablations, clustering analyses, and attention/geometry visualizations. These are informative for demonstrating empirical utility, but they do not directly verify the stronger semantic-alignment interpretation. Therefore, the paper’s language sometimes appears overclaimed unless the authors either provide more direct validation or narrow the interpretation to “useful morphology-aware visual priors” rather than explicit concept-level human alignment.
Questions
- Positioning relative to prior vision-based time-series modeling. How do the authors distinguish the paper’s conceptual novelty from prior work such as ViTime[1], which already advocates vision-based modeling of numerical time series through visual representations and image-space learning? Add ViTime to related work and explicitly discuss how ViRe differs. Clarify the novelty claim: is the novelty visual time-series modeling in general, medical waveform classification, CLIP-derived priors, or the cross-attention retrieval mechanism?
Ref: [1] ViTime: Foundation Model for Time Series Forecasting Powered by Vision Intelligence, 2025, Transactions on Machine Learning Research.
- Clarification of “human-describable concepts.” The phrase “human-describable concepts” is central to the paper’s motivation, but its meaning is not clearly defined. Do the authors refer to generic visual concepts that CLIP may encode, such as edges, spikes, trends, and shape patterns, or to clinically meaningful waveform concepts such as QRS complexes, ST-segment deviations, epileptiform discharges, and cross-channel co-activation patterns? A precise definition would make the claimed clinical alignment easier to assess.
A lightweight additional analysis could also help. For example, the authors could correlate Vision Query features or retrieval attention with simple morphology descriptors such as peak count, amplitude range, curvature, QRS-region overlap, or channel synchrony. This would help determine whether the visual prior captures human-observable waveform structure, rather than functioning only as an opaque auxiliary embedding.
- Evidence for semantic or concept-level alignment. The paper argues that CLIP-derived visual priors are aligned with human-describable or clinically meaningful waveform concepts. The ablation studies show that the visual prior is useful for prediction, and Appendix F provides initial attention-based evidence on high-curvature and QRS regions. However, it remains unclear whether this supports the stronger claim of concept-level semantic alignment.
Could the authors clarify what evidence they believe supports this interpretation beyond predictive improvement? If feasible, a small additional analysis would be useful, such as nearest-neighbor examples in the Vision Query space, qualitative case studies of attended waveform regions across different waveform patterns, or a curated check on recognizable attributes such as QRS morphology, spikes, amplitude changes, or cross-channel synchrony. Such analyses would help distinguish whether the CLIP-derived prior is merely helpful for optimization or genuinely meaningful in the concept-aligned sense implied by the paper. If this evidence is not feasible, I would encourage the authors to soften the related language in the abstract, introduction, and discussion.
Limitations
Yes
Final justification
The rebuttal improves the paper’s positioning by narrowing the claimed novelty to the query-only use of a frozen VLM-derived vision query and asymmetric vision–numerical interaction, and it also provides stronger evidence that the frozen CLIP-based visual prior contains morphology-related semantic structure. However, the new analyses mainly validate the visual prior itself, rather than directly showing that ViRe’s retrieval mechanism aligns the resulting numerical representations with human-describable concepts in the stronger sense claimed in the paper. The mechanism-level attribution therefore remains incomplete, since the rebuttal does not directly establish concept preservation in the projected Vision Query, cross-attention outputs, or retrieved numerical features. In addition, the new concept-level evidence is largely ECG-specific, while the paper’s main empirical claims span a broader MedTS setting covering both EEG and ECG benchmarks. Overall, the rebuttal partially addresses my concerns, but not enough to change my original score.
Formatting concerns
N.A.
6 comments
Rebuttal
We thank the reviewer for recognizing ViRe's clinical motivation, clear and easy-to-follow design, broad subject-independent evaluation, and informative ablations. We address three critical questions: (1) ViRe's novelty beyond visual time-series modeling, (2) the meaning of "human-describable concepts," and (3) direct evidence for concept alignment beyond predictive gains.
Q1. What is ViRe's novelty beyond prior visual time-series modeling?
We agree that time-series visualization and pretrained vision models are not individually novel. We discuss the mentioned ViTime [1] and one closely related recent work, Time-VLM [2].
| Method | Setting | Role of vision/VLM | Relation to numerical representations |
|---|---|---|---|
| ViTime | General forecasting | Forecasts in a binary image-based metric space. | The visual representation is the primary modeling space. |
| TimeVLM | Multimodal forecasting | Encodes visual/textual augmentations with VLMs. | Visual/textual embeddings are fused with temporal features. |
| ViRe | Medical time-series classification | Uses frozen CLIP waveform features only as a global Query. | Temporal and channel numerical tokens remain Keys/Values in two cross-attention paths. |
The novelty is therefore the interaction mechanism, not the use of images. Unlike ViTime, ViRe does not move prediction into image space; unlike Time-VLM, it does not fuse vision as a peer feature. Instead, the frozen visual representation has an asymmetric, query-only role that selects relevant evidence from the original numerical tokens.
Revision. We will clarify the above distinction in Related Work and narrow our contribution to:
ViRe uses a frozen VLM-derived global Vision Query to retrieve temporal and channel evidence from numerical medical time-series tokens through two cross-attention paths.
Q2. What do we mean by "human-describable concepts"?
We use the term at two measurable levels:
- Observable morphology: amplitude range, peak density, curvature, periodicity, spectral complexity, and cross-lead synchrony.
- Report-linked waveform attributes: HR, PR/QRS/QT/QTc, atrial fibrillation, conduction blocks, and ST-T abnormalities.
The term therefore refers to recognizable waveform properties, rather than claiming that every diagnosis is encoded or that individual embedding dimensions map one-to-one to clinical concepts.
Following the reviewer's suggestion, we test whether these attributes are decodable from the Vision Query. MEETI [3] pairs 12-lead waveforms with ECG images, measurements, and clinical reports. We use 662,400 quality-controlled ECGs from 154,802 patients, with patient-disjoint train/validation/test splits.
We train lightweight concept heads while keeping the encoder frozen. The control uses the same frozen encoder architecture initialized with fixed random weights; thus, only the concept heads are trained in either condition. Positive confidence intervals are obtained for all 22 supported attributes. Representative results are:
| Attribute | Frozen CLIP | Frozen random | Gain |
|---|---|---|---|
| Amplitude range (Spearman) | 0.903 | 0.501 | +0.402 |
| PR interval (Spearman) | 0.633 | 0.248 | +0.384 |
| Cross-lead synchrony (Spearman) | 0.684 | 0.320 | +0.364 |
| Prolonged QT (AUROC) | 0.904 | 0.656 | +0.248 |
These results show that observable morphology and report-linked waveform attributes are recoverable from the representation.
Revision. We will replace broader semantic and clinical wording and define "human-describable concepts" as:
"Human-describable concepts" refer to measurable human-observable morphology and report-linked waveform attributes captured by a morphology-aware visual prior.
Q3. What evidence supports concept alignment beyond predictive gains?
We agree that downstream accuracy and attention maps primarily establish utility. We therefore add three direct tests on MEETI, each comparing frozen pretrained CLIP with the identically frozen random encoder:
| Test | Protocol | Evidence |
|---|---|---|
| Zero-shot text alignment | Score held-out ECGs along paired CLIP text directions without a trained concept head. | Improvement for all 12 supported directions, including AF AUROC +0.423, QTc Spearman +0.284, amplitude +0.239, and synchrony +0.232. |
| Same-patient natural changes | Test whether within-patient feature changes follow HR/PR/QRS/QT/QTc changes. | Positive direction accuracy for all 5 measurements: HR +0.128, PR +0.154, QRS +0.127, QT +0.238, and QTc +0.144. |
| Raw-space retrieval | Retrieve frozen-space neighbours after excluding the query and all same-patient ECGs; no concept head is trained. | Positive confidence intervals for all 21 supported attributes, including bradycardia +0.337, HR +0.331, amplitude +0.262, QT +0.256, and QRS +0.245. |
These analyses test complementary properties: zero-shot scoring tests language association, longitudinal pairs track real physiological change while controlling patient identity, and retrieval tests the native geometry of the frozen space. Unlike Q2, which tests supervised decodability, raw-space retrieval uses no learned head and asks whether similar ECG attributes are already grouped together. Together, the results indicate meaningful waveform structure beyond improved task optimization.
Revision. We will narrow the central claim throughout the manuscript to:
Frozen CLIP provides a morphology-aware visual prior that preserves human-observable and report-linked ECG attributes.
[1] Yang et al., "ViTime: Foundation Model for Time Series Forecasting Powered by Vision Intelligence," TMLR, 2025.
[2] Zhong et al., "Time-VLM: Exploring Multimodal Vision-Language Models for Augmented Time Series Forecasting," ICML, 2025.
[3] Zhang et al., "MEETI: A Multimodal ECG Dataset from MIMIC-IV-ECG with Signals, Images, Features and Interpretations," Scientific Data, 2026.
Kindly request for Reviewer's Feedback
Dear Reviewer, thank you again for your detailed and helpful comments. With fewer than 48 hours left in the rebuttal period, we would greatly appreciate your feedback on whether our revised positioning relative to ViTime and Time-VLM, together with the new morphology- and concept-alignment analyses, sufficiently addresses your concerns regarding novelty and clinical interpretation.
We remain available to provide any further clarification.
Final Request for Feedback
Dear Reviewer, before Phase 2 closes (less than 3 hours), could you please let us know whether our revised positioning and new morphology- and concept-alignment evidence resolve your main concerns?
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 2/4
- Significance
- 2/4
- Originality
- 2/4
- Contribution type
- use_inspired
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
visual waveform prior knowledge
Strengths and weaknesses
Strenghts:
- The paper presents a good overview of the role of time series in medicine in different contexts, and modalities.
- The number of tasks and baselines is high - although some good baselines are missing.
Weaknesses:
- The baselines are not very strong, e.g, STRATS GRU-D seem relevant and strong alternatives, to the comparably old baselines.
- The experiment description is hard to follow, and a bit minimal. Please clarify and complete it so that it is immediately clear e.g., that you are evaluating classification tasks.
- The intuition of the advantage of using the image of the signal curves is not clear. Is this a spurious regularization advantage over just presenting the signal values? I am possibly misunderstanding the approach.
Questions
- Please provide a clear experiment description: start with the main points you want to show.
- Why only classification tasks and not interpolation / extrapolation?
- The intuition why the visual presentation of the curves should add anything to the result is completely unclear. Is this a matter of regularization that is easier in the visual space? Am I misunderstanding the approach.
Limitations
- Only classification tasks were evaluated.
Final justification
The authors have addressed concerns, especially regarding the comparison with state of the art approaches. Therefore, I am increasing my score of the paper.
Formatting concerns
There are no concerns regarding formatting.
3 comments
Rebuttal
We thank the reviewer for recognizing our broad medical scope and extensive evaluation. We address three points: (1) an explicit formulation of our primary subject-independent classification task and model pipeline, (2) evidence beyond general medical time-series classification, and (3) whether the visual branch contributes more than regularization.
Q1. What exactly is the task, and what does ViRe do?
We would first like to clarify that the manuscript consistently formulates ViRe as a medical time-series classification framework. The Introduction identifies MedTS classification as the problem of interest. More importantly, Sec. 3.1, “Preliminaries,” begins the Method by formally defining this task. The experimental section is likewise built entirely around this setting: all six EEG/ECG benchmarks use subject-independent classification, with Table 2 reporting the main classification. We agree, however, that this scope should also be restated explicitly at the beginning of the experimental section.
To make the task definition and the corresponding ViRe workflow easier to follow, we briefly restate them here. Given a multichannel waveform and label , the task is to learn under subject-disjoint splits, so that the model predicts a clinical or physiological class for an unseen subject. ViRe implements:
- Numerical tokens: and encode temporal and channel information.
- Vision Query: the same signal is rendered as ; a frozen CLIP encoder gives , which is projected to .
- Dual retrieval: and retrieve temporal and channel evidence from the numerical tokens.
- Classification: .
Thus, the flow is and , followed by .
Revision. We will begin the experimental section with:
Our primary evaluation is subject-independent medical time-series classification. Given , ViRe obtains a frozen-CLIP visual query from the waveform image and uses it to retrieve temporal and channel numerical evidence before predicting the class label.
Q2. Does ViRe extend beyond general MedTS classification and remain effective with stronger baselines?
The reviewer-mentioned GRU-D [1] and STraTS [2] are well-known methods for sparsely and irregularly sampled MedTS. Rather than forcing them onto our original densely sampled EEG/ECG classification setting, we add evaluations in the irregular MedTS domain: forecasting following Hi-Patch [3] (ICML'25) and classification following MTM [4] (KDD'25). This both tests transfer beyond general MedTS classification and introduces strong methods designed for irregular observations.
(1) irregular forecasting following Hi-Patch:
| Dataset | Metric | ViRe | Hi-Patch | t-PatchGNN | GRU-D |
|---|---|---|---|---|---|
| Human Activity | MSE ×10^-3 | 2.45± 0.04 | 2.57 ± 0.02 | 2.66 ± 0.03 | 3.94 ± 0.29 |
| MAE ×10^-2 | 3.04± 0.02 | 3.11 ± 0.03 | 3.15 ± 0.02 | 4.37 ± 0.21 | |
| PhysioNet | MSE ×10^-3 | 4.56± 0.04 | 4.86 ± 0.03 | 4.98 ± 0.08 | 5.76 ± 0.34 |
| MAE ×10^-2 | 3.44± 0.03 | 3.62 ± 0.07 | 3.72 ± 0.03 | 4.53 ± 0.15 | |
| MIMIC-III | MSE ×10^-2 | 1.56± 0.09 | 1.75 ± 0.26 | 1.69 ± 0.03 | 2.35 ± 0.06 |
| MAE ×10^-2 | 6.77± 0.11 | 7.24 ± 0.18 | 7.22 ± 0.09 | 8.34 ± 0.22 |
ViRe is best on all six metrics, reducing MSE relative to Hi-Patch by 4.4%/6.1%/10.8% on Human Activity/PhysioNet/MIMIC-III.
(2) irregular classification following MTM:
| Dataset | Metric | ViRe | MTM | STraTS | t-PatchGNN | GRU-D |
|---|---|---|---|---|---|---|
| P12 | AUROC | 88.5 ± 1.2 | 88.0 ± 1.0 | 86.4 ± 1.1 | 84.5 ± 0.9 | 81.9 ± 2.1 |
| AUPRC | 60.3 ± 2.4 | 58.6 ± 4.1 | 53.9 ± 3.1 | 50.8 ± 2.6 | 46.1 ± 4.7 | |
| P19 | AUROC | 91.3 ± 2.0 | 90.3 ± 2.0 | 89.7 ± 1.8 | 87.0 ± 1.4 | 83.9 ± 1.7 |
| AUPRC | 62.3 ± 4.3 | 58.3 ± 5.3 | 57.9 ± 3.3 | 51.5 ± 5.2 | 46.9 ± 2.1 | |
| PAM | Accuracy | 98.3 ± 0.6 | 97.5 ± 0.2 | 96.4 ± 0.8 | 93.9 ± 1.2 | 83.3 ± 1.6 |
| F1 | 98.4 ± 0.6 | 97.6 ± 0.2 | 95.3 ± 0.7 | 94.8 ± 1.2 | 84.8 ± 1.2 |
ViRe still ranks first on all six metrics.
Revision. We will clarify:
ViRe primarily targets general medical time-series classification; the same retrieval mechanism also transfers to irregular forecasting and irregular classification, where it remains competitive against recent strong irregular medical time-series baselines.
Q3. Why can the visual branch help, rather than merely regularize?
We agree that our original explanation was not sufficiently clear. The waveform image is a deterministic rendering of the numerical signal and therefore contains no additional measurement or label information. The benefit we claim is representational, not informational.
Why can the same signal help in image form? Rendering exposes global shape, intervals, periodicity, and cross-channel structure to a frozen CLIP encoder. ViRe does not use CLIP as an independent classifier or replace the numerical signal. It forms and uses only as the Query; the Keys and Values remain the temporal and channel tokens from . The visual prior therefore changes which numerical evidence is selected, rather than supplying new evidence.
Is the gain merely regularization? If so, an extra visual stream, generic image pretraining, or an arbitrary Query should give a similar benefit. The manuscript tests each prediction:
| Alternative explanation | Controlled result | Conclusion |
|---|---|---|
| Any extra visual-feature fusion helps | Table 4: Add/Concat give +4.05%/+3.02%, versus +7.72% for cross-attention retrieval. | Generic fusion explains only part of the gain; the retrieval interaction matters. |
| Any pretrained visual-feature helps | Table 5: ImageNet-ViT gives +0.34%, versus +7.72% for CLIP-Vision. | Generic visual pretraining is insufficient. |
| Any Query regularizes retrieval | Table 3: Zero/Gaussian Queries give +1.92%/+0.76%, versus +7.72% for the Vision Query. | The gain depends on information carried by the Query. |
These ablations argue against a generic regularization effect, but they do not identify what CLIP reads from the waveform. We therefore add a direct morphology check on MEETI [5], which pairs 12-lead waveforms and images with machine measurements and clinical reports. We use 662,400 quality-controlled ECGs from 154,802 patients and compare CLIP with the baseline initialized with fixed random weights.
| New test | Question addressed | Evidence over frozen random |
|---|---|---|
| Concept decoding | Are measurable attributes recoverable from the frozen representation? | Positive confidence intervals for all 22 attributes; amplitude Spearman 0.903 vs. 0.501, PR 0.633 vs. 0.248, and synchrony 0.684 vs. 0.320. |
| Zero-shot text alignment | Before attribute-specific fitting, do image features vary with paired text descriptions of ECG attributes? | Improvement for all 12 directions, including AF AUROC +0.423, QTc Spearman +0.284, amplitude +0.239, and synchrony +0.232. |
| Same-patient changes | Do the features follow real physiological changes when patient identity is held fixed? | Positive direction accuracy for HR/PR/QRS/QT/QTc: +0.128/+0.154/+0.127/+0.238/+0.144. |
The matched-random comparison rules out the frozen architecture alone; zero-shot alignment shows that attribute-related structure is present before task-specific fitting; and longitudinal pairs show that the representation follows real physiological changes rather than only patient or diagnosis identity. Thus, we do not claim that visualization adds information or that visual-space regularization is inherently easier. Our claim is narrower: frozen CLIP provides a morphology-aware prior that helps ViRe retrieve relevant evidence from the original numerical tokens.
Revision. We will state:
The waveform image contains no new measurements. Its benefit is representational: the frozen CLIP feature provides a morphology-aware Query that helps ViRe select relevant temporal and channel evidence from the original numerical tokens.
[1] Che et al., "Recurrent Neural Networks for Multivariate Time Series with Missing Values," Scientific Reports, 2018.
[2] Tipirneni and Reddy, "Self-Supervised Transformer for Sparse and Irregularly Sampled Multivariate Clinical Time-Series," ACM Transactions on Knowledge Discovery from Data, 2022.
[3] Luo et al., "Hi-Patch: Hierarchical Patch GNN for Irregular Multivariate Time Series," ICML, 2025.
[4] Zhong et al., "MTM: A Multi-Scale Token Mixing Transformer for Irregular Multivariate Time Series Classification," KDD, 2025.
[5] Zhang et al., "MEETI: A Multimodal ECG Dataset from MIMIC-IV-ECG with Signals, Images, Features and Interpretations," Scientific Data, 2026.
Kindly request for Reviewer's Feedback
Dear Reviewer, we sincerely appreciate your constructive feedback. As the rebuttal period will close in fewer than 48 hours, we would be grateful if you could briefly indicate whether our clarifications on the classification setting, broader evaluations, and the role of the visual branch beyond generic regularization have resolved your concerns.
We are open to any further clarification.
Brief Follow-Up Before Closure
Dear Reviewer, before Phase 2 close (with in 3 hours), we would greatly appreciate a brief assessment of our clarifications on task scope, stronger baselines, and the role of the visual branch beyond generic regularization.
- Rating
- 4/6
- Confidence
- 2/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 2/4
- Contribution type
- use_inspired
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
ViRe (Vision Informed Retrieval) analyzes medical time series, like ECGs and EEGs, to mirror how clinicians interpret these, by looking at the waveforms as shapes, rather than as numbers alone. This approach converts these medical time series into stacked waveform images, and passes it through a frozen CLIP-vision encoder to produce a morphology aware Vision Query. . This approach improved results over 10 baselines (6.4-16.4%. Ablations showed gain tied to CLIP's text-image alignment, rather than the generic pretraining, given performance of ImageNet-pretrained ViTs did not perform as well as expected.
Strengths and weaknesses
Strength. I very much like the concept of looking at time series as doctors do. Some of the morphology corresponds to clinically relevant events (especially with ECGs where specific waveforms are related to different moments in the cardiac cycle). So the morphology will be addressing important clinical findings. Clinicians have long made diagnoses based on very specific morphologies and patterns, so data would match the diagnoses and clinical concern more closely. The approach was well tested with public benchmark datasets (6 public benchmarks), 10 baselines, and ablations which convincingly identify source of gain. Interpretability was addressed. The interpretability is addressed at multiple levels.
Weakness The model should dive further into analyzing the visualization as there may be inadvertent effects of this approach. There is a chance that clinicians anchor too much on specific morphologies and lose some of the info models without morphology may identify. This would be circular as the gold standards would be based on clinician diagnosis and it may reinforce initial biases. It would help to have per-diagnosis breakdown to show if accuracy gain concentrates on morphologically obvious conditions (which could be arbitrary but selecting out a few key diagnoses would like ST elevation MI would help). Only modest gains.The largest gains are with the smallest subject datasets. Should have formal statistical significance testing beyond the Table 2 standard deviation reporting. There is no paired significance testing (gives mean +std over 5 seeds but many gains fall within overlapping ranges).
Questions
Can your report paired statistical significance testing between ViRe and the strongest baseline per dataset, rather relying on standard deviation (eg Wilcoxon signed rank or corrected paired t-tests)? Can you compare approaches by computational cost? Can you provide analysis of the results based on diagnosis? It would be good to see how accuracy compared forspecific important diagnoses are noted to be based on morphology such as ST elevation MI. Across different datasets, how stable are the large gains across different subject splits or under cross-validation?
Limitations
There is a limitation study which is clear. The main remaining gaps would be related to statistical concerns. Would need statistical testing. Would look more closely at PTB-XL dataset results Would report more info on clinical diagnoses made and allow for clinician validation of these diagnoses to determine how closely this interpretation is to human interpretation.
Final justification
Thank you for the authors' response. My concerns have been well addressed. I will keep my score unchanged.
Formatting concerns
none noted
3 comments
Rebuttal
We thank the reviewer for recognizing ViRe's clinical motivation, broad benchmark evaluation, ablations, and multi-level interpretability. We address three main points: (1) paired statistical significance and stability across subject partitions, (2) whether the gains extend across diagnoses rather than concentrating on a single obvious morphology, and (3) the computational cost of the visual pathway.
Q1. Are the gains statistically significant and stable across subject splits?
We add paired analyses against Medformer, the strongest baseline. Our primary new evidence comes from native PTB-XL, a substantially larger cohort than APAVA and PTB. The configuration and thresholds are fixed using official fold 9 before evaluation on the untouched fold-10 test set of 2,198 ECGs from 1,904 patients.
| Endpoint | ViRe | Medformer | Gain | Patient-cluster 95% CI |
|---|---|---|---|---|
| All 13 diagnoses | 64.93 | 61.57 | +3.36 | [+1.46,+5.10] |
| Official five superclasses | 72.26 | 68.52 | +3.74 | [+2.36,+5.14] |
Across five matched seeds, ViRe wins 5/5 comparisons for both endpoints. Mean all-13 macro F1 is 61.90 vs. 59.81 (paired -test ), while official-five macro F1 is 69.89 vs. 67.80 ().
We further freeze the same candidate and evaluate seven pre-specified, subject-disjoint official PTB-XL test folds (1, 2, 3, 4, 6, 8, and 10). ViRe wins all 7/7 folds:
| Endpoint | Mean gain | Wins | Wilcoxon | Corrected paired -test | Corrected 95% CI |
|---|---|---|---|---|---|
| All 13 diagnoses | +2.46 | 7/7 | 0.0156 | 0.0038 | [+1.14,+3.77] |
| Official five superclasses | +2.42 | 7/7 | 0.0156 | 0.0060 | [+0.99,+3.84] |
For the smaller APAVA and PTB cohorts highlighted by the reviewer, ten matched, stratified, subject-disjoint splits also give consistent paired gains:
| Dataset | Mean gain | Wins | Exact Wilcoxon/Holm |
|---|---|---|---|
| APAVA | +6.48 | 8/10 | 0.0371 |
| PTB | +3.98 | 9/10 | 0.0078 |
Thus, the latest evidence is not based on overlapping standard deviations: it consists of paired seed tests, patient-cluster confidence intervals, and repeated subject-disjoint evaluations, including a large PTB-XL cohort.
Q2. Do the gains extend across diagnoses, or only to obvious morphologies?
The diagnosis-level results show that the benefit is broad, while being strongest where morphology is clinically informative. We render each native 10-second, 12-lead PTB-XL record in a standardized simultaneous layout with a full lead-II rhythm strip, fixed axes, and a fixed mV range.
ViRe improves 11/13 diagnoses on the locked fold-10 test set (two-sided sign test ). Representative positive results are:
| Diagnosis | ViRe F1 | Medformer F1 | Gain | Patient-bootstrap 95% CI |
|---|---|---|---|---|
| MI | 72.21 | 71.35 | +0.85 | [-1.42,+3.08] |
| STTC | 74.91 | 73.44 | +1.47 | [-0.99,+3.97] |
| HYP | 59.49 | 44.17 | +15.32 | [+10.39,+20.25] |
| AMI | 72.93 | 71.01 | +1.92 | [-1.23,+5.14] |
| ISCA | 37.07 | 30.15 | +6.92 | [-2.03,+15.94] |
| LVH | 66.51 | 46.73 | +19.78 | [+13.98,+25.48] |
| AFIB | 67.08 | 62.61 | +4.47 | [-2.20,+10.98] |
The largest gains occur for HYP and LVH, whose diagnostic criteria strongly involve voltage and waveform morphology; both remain significant after Holm correction across all 13 diagnoses. Importantly, the positive directions also cover infarction, ST-T change, ischemia, and rhythm abnormalities. The improvement therefore does not arise from one diagnosis.
The reviewer suggested STEMI as an example. PTB-XL does not provide an adequately powered, clinically adjudicated STEMI endpoint in the locked test fold. We therefore analyze the better-supported related endpoints, MI, STTC, AMI, IMI, and ISCA, rather than using an unreliable STEMI proxy.
ViRe also retains the original numerical pathway: the visual feature is used only as a Query, while temporal and channel numerical tokens remain the retrieved evidence. When the numerical waveform and checkpoint are held fixed, zero-masking the visual input reduces all-13 macro F1 by 6.19 points (95% CI [+4.44,+8.06]), and cross-patient visual shuffling reduces it by 15.61 points ([+13.28,+17.85]); both Holm-adjusted .
These controlled interventions confirm that the gain depends on patient-matched visual morphology.
Q3. What is the computational cost?
The comparison is already reported in Appendix E, Table 8:
| Resource | ViRe | Medformer |
|---|---|---|
| Training time (ms) | 211.9 | 313.1 |
| Training memory (MB) | 698.2 | 838.4 |
| Inference time (ms) | 267.7 | 152.6 |
| Inference memory (MB) | 740.8 | 408.5 |
ViRe requires 32.3% less training time and 16.7% less training memory than Medformer under the same setup. The reported inference measurement includes waveform rendering and frozen visual-feature extraction.
Revision. We will add an explicit main-text pointer to Appendix E, Table 8 so that this comparison is easier to locate.
Kindly Request for Reviewer’s Feedback
Dear Reviewer, thank you again for your careful assessment. With fewer than 48 hours remaining in the rebuttal period, we would greatly appreciate it if you could let us know whether our additional paired significance tests, subject-disjoint evaluations, diagnosis-level analysis, and computational comparison have addressed your main concerns.
We would be happy to clarify any remaining points.
Final Request for Assessment
Dear Reviewer, Phase 2 closes shortly (within 3 hours). Could you please indicate whether our added statistical, subject-split, diagnosis-level, and efficiency analyses address your concerns?
Comments on the paper
2 comments
To Reviewers: check the rebuttal
Dear Reviewers,
We are approaching the end of the Phase 2 period (author + reviewer + AC discussion). Could you please review the authors’ responses and let us know whether they have adequately addressed your concerns? If you have any remaining questions or concerns, please feel free to raise them with the authors.
Best, AC
Request for Fair Final Assessment under Exceptional Phase 2 Circumstances
Dear Area Chair,
Despite our detailed rebuttal, individual follow-up requests, and your direct reminder, two reviewers have still not participated at all during Phase 2. Reviewer 1uLj responded only in the final hours and introduced concerns that materially differ from those in the original review.
The original review requested clearer positioning relative to ViTime, a precise definition of “human-describable concepts,” and direct concept-level evidence. We addressed these points through revised positioning, concept decoding, zero-shot text alignment, same-patient analyses, raw-space retrieval, and a narrowed central claim. The reviewer now requests mechanism-level concept attribution within the projected Vision Query, cross-attention outputs, and retrieved numerical features, together with separate EEG-specific concept validation. These are substantially stronger and newly introduced requirements, rather than unresolved original concerns. They were raised with almost no time remaining, leaving us no opportunity for further analysis or discussion.
We are also concerned about the care applied in this particular review of Reviewer 1uLj. The reviewer explicitly describes the paper as a ``use-inspired contribution," yet records the contribution type as General, although our submission was explicitly categorized as Use-inspired. Combined with the highly generic and formulaic wording, this review bears strong indications of AI-generated or substantially AI-assisted text without adequate human verification. We respectfully ask that it be assessed cautiously.
Under these exceptional circumstances, we sincerely ask that the final decision rely primarily on the paper itself, the complete rebuttal evidence, and your independent assessment. The unchanged reviews from non-participating reviewers, and newly introduced objections raised only after meaningful author response became impossible, should not unfairly determine the outcome. Similarly, any further substantive objections introduced only in Phase 3 should be treated with particular caution unless the authors are given an equivalent opportunity to respond.
At this stage, we can only rely on your judgment to ensure a fair and evidence-based decision.
Best regards,
The Authors
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Response to the Area Chair (Part-2)
4. Experimental setting and evaluation scope
ViRe is intended as a task-general MedTS representation framework. The original six-benchmark evaluation examines subject-independent MedTS classification.
Its broader scope is further evaluated under two established irregular MedTS protocols: forecasting following Hi-Patch [7] on Human Activity, PhysioNet, and MIMIC-III, and classification following MTM [8] on P12, P19, and PAM. ViRe ranks first on every reported metric against Hi-Patch [7], MTM [8], STraTS [9], t-PatchGNN [10], and GRU-D [11].
These results provide direct empirical evidence that the Vision-Informed Retrieval mechanism generalizes across prediction tasks and observation regimes, supporting ViRe’s scope as a task-general MedTS representation framework.
References
[1] A. Radford et al., “Learning Transferable Visual Models from Natural Language Supervision,” ICML, 2021.
[2] L. Yang, Y. Wang, X. Fan, I. Cohen, J. Chen, and Z. Zhang, “ViTime: Foundation Model for Time Series Forecasting Powered by Vision Intelligence,” TMLR, 2025.
[3] S. Zhong, W. Ruan, M. Jin, H. Li, Q. Wen, and Y. Liang, “Time-VLM: Exploring Multimodal Vision-Language Models for Augmented Time Series Forecasting,” ICML, 2025.
[4] D. Zhang et al., “MEETI: A Multimodal ECG Dataset from MIMIC-IV-ECG with Signals, Images, Features and Interpretations,” Sci. Data, 2026.
[5] Y. Wang, N. Huang, T. Li, Y. Yan, and X. Zhang, “Medformer: A Multi-Granularity Patching Transformer for Medical Time-Series Classification,” NeurIPS, 2024.
[6] P. Wagner et al., “PTB-XL, a Large Publicly Available Electrocardiography Dataset,” Sci. Data, 2020.
[7] Y. Luo, B. Zhang, Z. Liu, and Q. Ma, “Hi-Patch: Hierarchical Patch GNN for Irregular Multivariate Time Series,” ICML, 2025.
[8] S. Zhong, W. Zhuo, S. Song, G. Li, Z. Yu, and S.-H. G. Chan, “MTM: A Multi-Scale Token Mixing Transformer for Irregular Multivariate Time Series Classification,” KDD, 2025.
[9] S. Tipirneni and C. K. Reddy, “Self-Supervised Transformer for Sparse and Irregularly Sampled Multivariate Clinical Time-Series,” TKDD, 2022.
[10] W. Zhang, C. Yin, H. Liu, X. Zhou, and H. Xiong, “Irregular Multivariate Time Series Forecasting: A Transformable Patching Graph Neural Networks Approach,” ICML, 2024.
[11] Z. Che, S. Purushotham, K. Cho, D. Sontag, and Y. Liu, “Recurrent Neural Networks for Multivariate Time Series with Missing Values,” Sci. Rep., 2018.