potentialpaper

Inertia-1: An Open Exploration of Wearable Motion Foundation Models

Zongzhe Xu, Aakarsh Anand, Sarah Jiang, Chuntung Zhuang, Zitao Shuai, Sriram Sankararaman, Yuzhe Yang

GenAI4Health @ NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

TL;DR. Inertia-1 presents a fully open exploration of wearable motion foundation models, providing a comprehensive, practical, and open cookbook for wearable motion representation learning.

Abstract. Wearable motion sensing provides a continuous and scalable window into human behavior and health, making it a natural fit for foundation models, yet its pretraining and scaling principles remain poorly understood. Prior work studies isolated design choices, such as sensor placement or sampling frequency, often under fixed settings and narrow downstream tasks that fail to capture real-world sensing diversity. We introduce Inertia-1, a fully open exploration of wearable motion foundation models. Using massive corpora of accelerometer data from global sources spanning more than 18.2M hours, we build a controlled framework for studying the full lifecycle of wearable motion foundation models, covering data choices such as sensor modality, device placement, sampling rate, window length; model choices such as architectures and model size; and training choices such as pretraining objective and data scale. Extensive evaluations across 15 datasets spanning human activity recognition, freezing-of-gait detection, and disease prediction reveal intriguing findings for building motion foundation models that generalize across tasks and sensing conditions. Collectively, Inertia-1 not only presents state-of-the-art recipes for diverse downstream tasks, but also serves as a comprehensive, practical, and open cookbook for wearable motion representation learning.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

FromAToBDateVersionSubmitted toPDFEvidence
30 Apr 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]PDF[1]
22 Aug 2026GenAI4Health @ NeurIPS 2026submittedGenAI4Health @ NeurIPS 2026Accepted · Oral—[1]
Their titles, abstracts and, where both have a PDF, the text.Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:44 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

Reviewers describe the study as comprehensive and carefully executed. It covers many pretraining objectives, downstream tasks, and design choices. All three found the manuscript clear and well structured despite the number of experiments. Reviewer Cr43 rated both quality and clarity excellent. Reviewers Cr43 and BMQ7 praise the breadth of the evaluation and the practical value of comparing learning objectives across task families.

However, Yzzk and BMQ7 question whether the findings amount to a contribution. Yzzk argues that the headline conclusions restate what the wearable and time-series communities converged on several years ago, and what vision and NLP established earlier. Related, BMQ7 asks for an explicit comparison against existing wearable motion foundation models and notes that the paper asserts rather than demonstrates that prior work addresses only isolated design choices. Both reviewers conclude that the work is better characterized as benchmarking than as a methodological advance, and both suggest the framing should be adjusted accordingly. While Yzzk objects that the presentation implies a data contribution where the corpus aggregates existing public datasets, reviewers Cr43 and BMQ7 both note that the practical recommendations arrive without much explanation of why particular choices prevail. This leaves readers with mere observations.

Reviewer Cr43 brings up the strongest technical concern despite being most positive: the conclusions rest on AUROC differences reported without confidence intervals, significance tests, or across-run variability, while several of those differences are modest.

In addition, the benefit of self-supervision seems to grow much from activity recognition through gait to disease prediction. Reduced sampling rate degrades clinical prediction, which is reasonable, but leaves activity recognition unaffected?

For the response:

  • Statistical uncertainty on the main tables, and a restatement of which conclusions survive it
  • A clear separation of findings that were genuinely not known from those that confirm existing belief
  • Explicit positioning against prior motion foundation models
  • Corrected framing around the corpus and the naming

After discussion:

The rebuttal and discussion addressed the main concerns. The authors added bootstrap confidence intervals and significance tests for the central comparisons. These analyses support most of the main conclusions and led the authors to narrow the triaxial-input claim to most, rather than all, task families. They also added analyses that better explain the sampling-rate and FoG results. This addresses the concern that some recommendations were based mainly on empirical observations without interpretation.

The remaining disagreement concerns the significance of the contribution. I agree with Reviewers Yzzk and BMQ7 that several individual findings are confirmatory and that the paper's main contribution is empirical rather than methodological. However, the discussion clarified the contribution of the controlled study across task families, sensing choices, scale, placements, and sensor modalities. The added LIMU-BERT and LSM-2 results also strengthen the comparison with prior wearable motion foundation models. Reviewer Cr43 recommends acceptance, Reviewer BMQ7 recommends borderline acceptance, and Reviewer Yzzk raised their score to borderline reject, with the remaining concern focused on significance rather than technical soundness.

I therefore change my recommendation to Accept (poster). The camera-ready should reflect the framing established during discussion: present the work as a large-scale controlled empirical study and experimental framework; clearly distinguish confirmatory findings from the main new findings; state the planned release and license; and include the promised uncertainty reporting and statistical details. The narrowed triaxial-input claim should be retained.

Final justification

I changed my preliminary recommendation from Reject to Accept after considering the rebuttal and discussion. The authors added uncertainty analysis for the main comparisons, narrowed a claim that was not supported across all task families, added requested wearable-motion baselines, and clarified the paper's empirical framing and planned release. The remaining reviewer concern is mainly about significance rather than technical soundness. I find the controlled analysis across tasks, sensing settings, and transfer conditions sufficiently significant for acceptance. The camera-ready should follow the framing, release, and uncertainty-reporting commitments made during discussion.

The discussion phase moved this paper up: two reviewers raised their assessments after the response. The most positive reviewer re-confirmed a recommendation to accept after the contribution-type reclassification. The reviewer who remains most reserved raised their assessment to borderline and stated explicitly that their residual hesitation concerns significance rather than technical soundness and that they would follow the discussion with an open mind.

The authors submitted three confidential comments. Two argued that individual reviewers had misunderstood the scope or contribution of the work. I read and considered all three. The substance of those arguments was also made in the public threads, where the reviewers in question engaged with it directly. One accepted the point about the originality and significance criteria and revised upward as a result. My recommendation is based on the public record and on the strength of the response (not on the confidential messages). I would have reached the same conclusion without them.

Area Chair 7oFj · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

Reviewers describe the study as comprehensive and carefully executed. It covers many pretraining objectives, downstream tasks, and design choices. All three found the manuscript clear and well structured despite the number of experiments. Reviewer Cr43 rated both quality and clarity excellent. Reviewers Cr43 and BMQ7 praise the breadth of the evaluation and the practical value of comparing learning objectives across task families.

However, Yzzk and BMQ7 question whether the findings amount to a contribution. Yzzk argues that the headline conclusions restate what the wearable and time-series communities converged on several years ago, and what vision and NLP established earlier. Related, BMQ7 asks for an explicit comparison against existing wearable motion foundation models and notes that the paper asserts rather than demonstrates that prior work addresses only isolated design choices. Both reviewers conclude that the work is better characterized as benchmarking than as a methodological advance, and both suggest the framing should be adjusted accordingly. While Yzzk objects that the presentation implies a data contribution where the corpus aggregates existing public datasets, reviewers Cr43 and BMQ7 both note that the practical recommendations arrive without much explanation of why particular choices prevail. This leaves readers with mere observations.

Reviewer Cr43 brings up the strongest technical concern despite being most positive: the conclusions rest on AUROC differences reported without confidence intervals, significance tests, or across-run variability, while several of those differences are modest.

In addition, the benefit of self-supervision seems to grow much from activity recognition through gait to disease prediction. Reduced sampling rate degrades clinical prediction, which is reasonable, but leaves activity recognition unaffected?

For the response:

  • Statistical uncertainty on the main tables, and a restatement of which conclusions survive it
  • A clear separation of findings that were genuinely not known from those that confirm existing belief
  • Explicit positioning against prior motion foundation models
  • Corrected framing around the corpus and the naming

After discussion:

The rebuttal and discussion addressed the main concerns. The authors added bootstrap confidence intervals and significance tests for the central comparisons. These analyses support most of the main conclusions and led the authors to narrow the triaxial-input claim to most, rather than all, task families. They also added analyses that better explain the sampling-rate and FoG results. This addresses the concern that some recommendations were based mainly on empirical observations without interpretation.

The remaining disagreement concerns the significance of the contribution. I agree with Reviewers Yzzk and BMQ7 that several individual findings are confirmatory and that the paper's main contribution is empirical rather than methodological. However, the discussion clarified the contribution of the controlled study across task families, sensing choices, scale, placements, and sensor modalities. The added LIMU-BERT and LSM-2 results also strengthen the comparison with prior wearable motion foundation models. Reviewer Cr43 recommends acceptance, Reviewer BMQ7 recommends borderline acceptance, and Reviewer Yzzk raised their score to borderline reject, with the remaining concern focused on significance rather than technical soundness.

I therefore change my recommendation to Accept (poster). The camera-ready should reflect the framing established during discussion: present the work as a large-scale controlled empirical study and experimental framework; clearly distinguish confirmatory findings from the main new findings; state the planned release and license; and include the promised uncertainty reporting and statistical details. The narrowed triaxial-input claim should be retained.

Final justification

I changed my preliminary recommendation from Reject to Accept after considering the rebuttal and discussion. The authors added uncertainty analysis for the main comparisons, narrowed a claim that was not supported across all task families, added requested wearable-motion baselines, and clarified the paper's empirical framing and planned release. The remaining reviewer concern is mainly about significance rather than technical soundness. I find the controlled analysis across tasks, sensing settings, and transfer conditions sufficiently significant for acceptance. The camera-ready should follow the framing, release, and uncertainty-reporting commitments made during discussion.

The discussion phase moved this paper up: two reviewers raised their assessments after the response. The most positive reviewer re-confirmed a recommendation to accept after the contribution-type reclassification. The reviewer who remains most reserved raised their assessment to borderline and stated explicitly that their residual hesitation concerns significance rather than technical soundness and that they would follow the discussion with an open mind.

The authors submitted three confidential comments. Two argued that individual reviewers had misunderstood the scope or contribution of the work. I read and considered all three. The substance of those arguments was also made in the public threads, where the reviewers in question engaged with it directly. One accepted the point about the originality and significance criteria and revised upward as a result. My recommendation is based on the public record and on the strength of the response (not on the confidential messages). I would have reached the same conclusion without them.

1 comment
Authors · CommentOpenReview ↗

Response to the AC Meta Reivew

We thank the AC for the careful synthesis. We believe so far our rebuttals and additional analyses have addressed all questions and weaknesses raised by the reviewers, and we would like to summarize the corresponding responses below:

Metareview point Addressed in Main takeaway
Statistical uncertainty and which conclusions remain supported Cr43 — W3 We add bootstrap 95% confidence intervals and significance tests for the central sampling-rate, window-length, axis, and SSL-versus-supervised comparisons. Most conclusions remain supported; we revise the triaxial-input claim to apply to most rather than all task families. We will add CI across all tasks under appendix when revising the manuscripts to better support our extensive evaluation.
Explicit positioning against existing wearable motion foundation models BMQ7 — W1/Q1 Inertia-1 does not claim to introduce the strongest new model. Rather, it uses a unified, controlled framework to compare previously fragmented choices across objectives, tasks, sensing configurations, scale, placements, and modalities, enabling new conclusions about task-dependent design tradeoffs, scaling behavior, cross-placement and cross-sensor transfer, and the complementary value of multiple sensor streams.
Separation of genuinely new findings from established observations Yzzk — novelty response; BMQ7 — W2/Q2 We believe the novelty assessment overemphasizes one confirmatory result: “SSL outperforming training from scratch” while not engaging with the paper’s central contributions. Inertia-1’s novelty lies in its controlled framework and the previously unavailable conclusions and the fully original insights it enables: how self-supervision changes across task families (Section 4.1), how sensing and scaling choices interact (Section 4.2 & 4.3), and how representations transfer across placements, sensor modalities, and multiple streams (Section 4.4). We welcome concrete suggestions, but believe the current novelty assessment mischaracterizes the paper’s central claims.
Recommendations require explanations rather than empirical observations alone Cr43 — W2 and W1/Q2 We add targeted mechanistic analyses. On WISDM, low-rate HAR remains strong because near-stationary activities require little high-frequency information, whereas dynamic classes degrade more substantially. On FoGTurning, spectrogram-based Self-PAB is disproportionately weak for episodes shorter than its 3.2 s analysis frame, providing evidence that fixed time-frequency granularity can obscure brief events. We also discuss why wearable-specific objectives may transfer less robustly under heterogeneous shared settings.
Why reduced sampling affects clinical prediction but appears not to affect HAR Cr43 — W2 and W3 HAR is not unaffected: reducing ART from 20 Hz to 1 Hz lowers mean AUROC from approximately 95.3 to 91.3, with (p<0.01). Aggregate performance remains comparatively strong because near-stationary classes are preserved, whereas locomotion and other dynamic classes lose 2.5–3.4 AUROC points. Disease prediction also degrades significantly, although its wider uncertainty reflects fewer datasets and smaller clinical cohorts.
Correct framing of the 18.2M-hour corpus Yzzk — corpus response The paper already states in the abstract, introduction, and Section 3 that the 18.2M hours are aggregated from 15 existing datasets; it does not present new data collection as a contribution. The contribution is the harmonization of these heterogeneous datasets into a controlled, comparable framework. We will nevertheless further sharpen the wording to eliminate any possible ambiguity.
Corrected framing and naming of the work Yzzk — framing response; BMQ7 — W2/Q2 We will position the paper explicitly as a large-scale controlled empirical study rather than a new-method or new-dataset contribution. “Inertia-1” refers to the open experimental framework and associated resources, not a newly proposed architecture.
Broader baseline and practical-compute coverage BMQ7 — W3/Q3 and W4/Q4 We report model size, FLOPs, server-GPU latency, memory, and throughput under standardized settings, while clarifying that these measurements do not constitute an embedded-device benchmark. We have also implemented LIMU-BERT and LSM-2 under the matched protocol and reported the completed results.

We remain happy to provide any further clarification and hope to engage with the reviewers during discussion to address any remaining concerns.

Reviewer YzzkOpenReview ↗
Rating
3/6
Confidence
5/5
Quality
3/4
Clarity
3/4
Significance
2/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This manuscript provided a review to foundation models for wearable motion sensing. Systematically examines how data, model, and training choices, such as sensor placement, sampling rate, architecture, pretraining objective, and scale. This study also evaluated across 15 datasets covering activity recognition, freezing-of-gait detection, and disease prediction, it delivers state-of-the-art results and practical guidance for building generalizable wearable motion representations.

Strengths and weaknesses

This manuscript explored how pre-training objectives, sensing configurations, scale, and downstream tasks jointly shape transferable motion representations. The authors put together large amount of wearable motion data including multiple datasets. According to those comparisons of SSL models and supervised baselines across HAR dataset, FoG tasks, and disease prediction tasks, this study summarized the finding of self-supervised pretraining consistently outperforms supervised training from scratch across task categories, and the result suggests strong representations learned from unlabeled population cohorts regardless of the specific downstream application. However, this is a well-established finding, the wearable/time-series community has been converging on the same conclusion since roughly 2022. The claimed finding mirrors the established narrative from NLP(BERT, GPT) and vision (MAE, SimCLR, MoCo), where SSL on large unlabeled corpora (e.g., 18M+ hours) consistently beats supervised-from-scratch on limited labeled data.

There are limitations of the novelty for this study. For example, as conclusion (line 383-385) mentioned, "we find that self-supervised pretraining consistently improves transfer over supervised training from scratch, but no single objective dominates across all task families". For the first half of this conclusion, SSL improves over supervised from scratch, a well established and discussed topic. It's not a contribution on this manuscript. I agree with that the second half of this conclusion has modest novelty but not entirely surprising, because the time-series and vision SSL communities have observed this for a while, e.g., SimCLR, MoCo these contrastive methods tend to favor discrimination tasks and BERT-style masked reconstruction tends to favor dense/generative understanding.

In addition, the 18.2M hours figure is an aggregation of existing public datasets, not a newly collected corpus, this should be stated more clearly upfront rather than presented in a way that implies data collection as a contribution. The abstract's phrasing does technically acknowledge this, but the overall framing still gives the impression of a data contribution. The real contributions are the controlled experimental framework and the empirical findings

Questions

The suggestion is consider to submit this manuscript to a journal might be more competitive. The work is solid and carefully done, as authors mentioned at the end, it's a comprehensive cookbook for wearable motion representation learning, but at its core it's more about pulling things together and measuring them than actually introducing something new. The "Inertia-1" branding and "fully open exploration" framing somewhat overstate the novelty. The core deliverable, a systematic sweep of design choices across existing datasets and architectures, reads more as a large-scale benchmarking or survey effort than a novel methodological contribution.

Limitations

Yes.

Final justification

Based on the authors' responses, I am raising my score to 3, as a borderline rating, and adjusting my originality assessment upward accordingly. My remaining hesitation is about significance rather than technical soundness, and I will follow the discussion with the other reviewers and the AC with an open mind.

Formatting concerns

No.

4 comments
Authors · RebuttalOpenReview ↗
Rebuttal

Thank you for your detailed feedback. We respectfully believe this assessment overlooks several central contributions of the paper and places disproportionate emphasis on one high-level result. We clarify the scope, novelty, and primary findings of the work point by point below:

 

Weakness - paragraphs 1 & 2: … limitations of the novelty for this study …this is a well-established finding, the wearable/time-series community has been converging on the same conclusion since roughly 2022

We first want to address the reviewer’s comments regarding the novelty of this work. We would like to note that the originality of this work is consistent with NeurIPS's own stated originality criteria in the reviewing guidelines. The General track's Originality criterion is explicit in that

“originality does not necessarily require introducing an entirely new method. Rather, a work that provides novel insights by evaluating existing methods, or demonstrates improved efficiency, fairness, etc. is also equally valuable.”

Additionally, the Significance criterion similarly is evaluated as:

“unique conclusions about existing data, or a unique theoretical or experimental approach.”

By these criteria, we believe Inertia-1's unification of a fragmented experimental space, and the conclusions that unification makes possible, fall exactly within the type of contribution recognized by these criteria.

Additionally, while we agree that SSL-beats-supervised-from-scratch is well established outside wearable sensing, we would like to clarify that this is not the paper's central contribution. We believe the review's framing conflates one confirmatory result with the paper's actual claims. The inclusion of the SSL and supervised methods comparison is used to validate that our experimental framework behaves as expected, that pretraining was successful, before we use it to evaluate the questions the paper is actually about. The paper's main claims, which we don't believe are addressed in the review, are:

  1. How the benefit of self-supervision itself shifts across task families from activity recognition through gait to disease prediction (Section 4.1),
  2. How these effects interact with data and modal scaling (Section 4.2),
  3. The influence of design and preprocessing choices in training (Section 4.3),
  4. Generalization across body placements and complementary gains from multiple sensor streams (Section 4.4).

To the best of our knowledge, none of these are established findings in NLP, vision, or the wearable/time-series literature; each requires the kind of controlled, cross-cutting comparison that no single prior wearable motion study has run. We certainly welcome any concrete suggestions from the reviewer on prior studies to compare with.

To summarize, we believe the review reflects several misunderstandings regarding the paper’s contribution, scope, and positioning. The review’s novelty assessment centers primarily on one confirmatory finding while not engaging with the paper’s main contributions; we therefore respectfully believe that the reviewer’s assessment of limited novelty is not supported by the specific arguments provided in the review.

 

Weakness - paragraphs 3: the 18.2M hours figure is an aggregation of existing public datasets, not a newly collected corpus …

Additionally, we appreciate the reviewer’s comments regarding the data corpus and how it is presented in this work. We would like to respectfully identify specific instances in the text in which we address this, including:

  1. Abstract: data are drawn from “global sources” and evaluated “across 15 datasets.”
  2. Introduction, lines 56–58: “we aggregate … 18.2M hours of motion data from more than 115,000 people and 15 datasets.”
  3. Section 3, lines 115–117: Inertia-1 “aggregates 15 datasets across 3 task families and 18 downstream tasks.” Accordingly, we do not present the creation of a new dataset as a contribution. Our contribution is the harmonization of existing datasets into a controlled and comparable framework spanning diverse tasks, sensing configurations, and modeling choices. To avoid any remaining ambiguity, we will revise the wording to make this distinction even more explicit and prevent the scale of the aggregated corpus from being interpreted as a new data-collection claim.

 

Question: … consider submitting this manuscript to a journal … it's more about pulling things together and measuring them than actually introducing something new … more as a large-scale benchmarking or survey effort than a novel methodological contribution.

Lastly, regarding the reviewer’s suggestion to submit this work to a journal rather than NeurIPS, while we appreciate the suggestion, we respectfully disagree and clarify below both the scope of our contribution and its fit within NeurIPS.

Scope of Contribution. Inertia-1 is not a survey or a simple aggregation of prior results. Our work (1) unifies 15 heterogeneous wearable motion datasets under a controlled training and evaluation framework, (2) systematically compares representative pretraining objectives across HAR, FoG, and disease prediction, (3) characterizes how sampling rate, window length, axis representation, input domain, model scale, and data scale affect transfer, and (4) studies generalization across body placements and sensor modalities, including the complementary benefits of multi-stream sensing. These conclusions require training and evaluating more than 1,000 models under matched protocols and cannot be obtained by summarizing the existing fragmented literature.

Nature of Novelty. The paper does not claim novelty from introducing a new pretraining objective. Its novelty lies in the experimental framework and the previously unavailable conclusions enabled by it. In particular, we show that objective differences widen substantially beyond standard HAR, that increasing data diversity is more reliable than increasing model size alone, that sensing choices have task-dependent effects, and that wrist-accelerometer pretraining transfers across placements and sensor types. We therefore respectfully disagree with the characterization that the work merely “pulls things together and measures them.”

Precedent at NeurIPS. NeurIPS has clear precedent for systematic empirical studies whose primary contribution is to characterize existing methods, disentangle previously conflated design choices, and derive new conclusions through controlled experimentation [1] [2] [3][4]. These works demonstrate that a contribution need not introduce a new learning objective or architecture when its experimental design enables insightful new understanding. We believe Inertia-1 fits this contribution style by unifying previously fragmented wearable-motion settings and deriving findings that individual prior studies could not establish.

References:

  1. Subramanian, Shashank, et al. "Towards foundation models for scientific machine learning: Characterizing scaling and transfer behavior." NeurIPS 2023.
  2. Ben-Shaul, Ido, et al. "Reverse engineering self-supervised learning." NeurIPS 2023.
  3. Kazemnejad, Amirhossein, et al. "The impact of positional encoding on length generalization in transformers." NeurIPS 2023.
  4. Park, Seohong, et al. "Is value learning really the main bottleneck in offline RL?." NeurIPS 2024.

 


We sincerely thank the reviewer once again for their time and constructive feedback. To support the community and enable future research, we remain committed to fully open-sourcing our research. We hope our detailed responses and the additional experiments have addressed all of your concerns, and we would be happy to answer any remaining questions during the discussion period. We would be very grateful if you might consider raising your score and championing the paper in light of these updates.

Authors · CommentOpenReview ↗

Discussion Period Ending Soon: Follow-Up for Reviewer Yzzk

We would like to thank the reviewer again for your time and effort. In response to your latest comments, we have provided additional results and clarifications that we hope have addressed your remaining concerns.

Given there is only 1 days left in the discussion period, we wanted to kindly followup to check if the reviewer had seen our latest comment and whether there were any final clarifications that we can address. If the concerns of the reviewer are resolved and the reviewer is convinced of the novelty and completeness of our work, we'd be grateful if the reviewer could update your review and score to reflect that, so we know that our response has been seen.

Once again, many thanks for your time and dedication to the review process, we are extremely grateful.

Reviewer Yzzk · CommentOpenReview ↗

Thank you for the detailed and constructive rebuttal. I have re-read the paper in light of your response, and I want to acknowledge the points where your clarifications are persuasive, as well as explain where my reservations remain. First of all, I accept your point regarding the NeurIPS originality and significance criteria. You are correct that a controlled empirical study of existing methods can constitute a valid contribution under the reviewing guidelines, and the precedents you cite ([1]-[4]) support that this contribution style has a place at the conference. My original review placed weight on the SSL-versus-supervised comparison, which, as you clarify, functions as a validation of the experimental framework rather than as the paper's central claim.

For the concern of ambiguity about '18.2M hours of motion data', I appreciate the commitment to revising the framing of the 18.2M-hour corpus so that it cannot be read as a data-collection claim. The specific text locations you point to do state this, and a sharper abstract will resolve the ambiguity.

For my concerns about significance, while the cross-cutting comparison is new to this domain, several of the individual conclusions land close to what one would extrapolate from the vision and time-series SSL literature: for example, the finding that contrastive objectives favor discriminative tasks while masked reconstruction favors dense understanding follows the established pattern, and confirming it in a new domain is useful but incremental. The practical value of the "cookbook" depends heavily on the promised open-sourcing of the framework, pretrained models, and evaluation protocols. I would ask the authors to state concretely in the revision what will be released and under what license, since the contribution is substantially weaker if the community cannot build on the harmonized setup directly.

Finally, I would encourage the revision to foreground the four enumerated claims in both the abstract and introduction, so that the paper's positioning matches the contribution the rebuttal describes.

On reflection, I thank the authors for prompting me to revisit this. I am raising my score to 3, as a borderline rating, and adjusting my originality assessment upward accordingly. My remaining hesitation is about significance rather than technical soundness, and I will follow the discussion with the other reviewers and the AC with an open mind.

Authors · CommentOpenReview ↗

Response to Reviewer Yzzk's Comments

Thank you for revisiting the paper and for acknowledging that the SSL-versus-supervised comparison is not our central contribution. We also appreciate your recognition that our comprehensive study constitutes a valid contribution under the NeurIPS criteria.

 

We believe, however, there remains important misunderstandings for interpreting our results which we would like to clarify and address point-to-point:

First, the reviewer suggests that our conclusions follow the established pattern that “contrastive objectives favor discriminative tasks while masked reconstruction favors dense understanding.” However, this is factually incorrect. Our paper does not evaluate any dense prediction or generative-understanding task. All downstream evaluations are discriminative, i.e., classification-based tasks evaluated using AUROC and AUPRC (Page 9, Line 377): human activity recognition, freezing of gait detection, and disease prediction (Appendix A.3, Table 8. Section 4.4, Line 354. ).

Second, even within these classification tasks, our results do not support the “contrastive vs. masked ordering” stated in the review. PatchTST, a masked reconstruction approach, is among the strongest models on discriminative HAR tasks, while predictive, contrastive, self-distillation, and wearable specific objectives lead on different FoG datasets and disease outcomes. Our conclusion is therefore – in the contrary to what the reviewer stated – precisely that a simple objective-family taxonomy does not predict performance consistently across wearable motion task regimes.

Most importantly, the objective comparison is only one component of Section 4.1. The paper’s central findings instead reveal (1) task-dependent pretraining behavior (Section 4.1), (2) data vs. model scaling (Section 4.2), (3) sensing and preprocessing choices (Section 4.3), and (4) transfer across body placements and sensor modalities with complementary multi-stream gains (Section 4.4). These findings cannot be reduced to a contrastive-versus-masked distinction and have not previously been established together through a unified study at modern pretraining scale.

We certainly welcome any concrete references to prior from the reviewer; otherwise, we believe that Inertia-1 is the first to reveal these insights jointly and to translate them into practical guidance for the wearable sensing community.

 

Open‑source commitment. We agree the release scope should be stated concretely. We are committed to fully releasing our framework including:

  1. Data. While all datasets used are publicly available online, we will release the complete preprocessing pipeline for all the datasets to fully reproduce our results.
  2. Pretrained models. We will release our model checkpoints trained on these data with example code for inference and fine-tuning.
  3. Code. We will open source our complete experiment configurations across all downstream settings, training and evaluation pipelines to enable full reproduction of our results and benefit the broader research community. Everything above will be open-sourced under MIT license with comprehensive documentation for reproducing the experiments and extending the framework with new datasets, models, and tasks.

 


As a result, we believe there remain misunderstandings and factually incorrect characterizations of our paper. We hope the clarification, together with our earlier rebuttal, addresses all remaining concerns of the reviewers. We remain happy to provide further clarifications. If the reviewer agrees that all concerns have been addressed, we would be grateful if the reviewer could update the review and score to reflect the paper’s actual contributions and the clarifications provided.

Reviewer BMQ7OpenReview ↗
Rating
4/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
2/4
Originality
2/4
Contribution type
use_inspired
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

In this paper, the authors conduct an open exploration of wearable motion foundation models across multiple large-scale datasets. They show that self-supervised pretraining generally improves transfer performance, but no single objective works best for all tasks. They also find that data representation, temporal resolution, sensor placement, and pretraining scale are as important as model architecture.

Strengths and weaknesses

Strengths:

First, the authors conduct an open exploration of wearable motion foundation models across multiple large-scale datasets.

Second, based on extensive experimental results, the authors provide useful insights into wearable motion foundation models, including the impact of pretraining objectives, data representation, temporal resolution, sensor placement, and pretraining scale.

Weaknesses:

First, the authors should more clearly discuss the differences between this work and existing state-of-the-art wearable motion foundation models. Although the authors claim that prior motion FM studies often focus on a single objective, or task setting, the paper should provide a more detailed comparison to clarify the unique scope and contribution of this work.

Second, the technical novelty of this paper appears limited. The main contribution is the experimental exploration and the insights derived from the results, rather than the development of new pretraining methods or fine-tuning strategies. The authors should better position the paper as an empirical study and clarify the novelty beyond benchmarking.

Third, the experimental analysis should be further strengthened. For example, the authors should also report system-level or inference performance, including latency, memory usage, and computational cost, especially for wearable device deployment. In addition, the authors should include more self-supervised learning methods such as LIMU-IMU for IMU sensing in the comparison to better demonstrate the comprehensiveness of the study.

Xu, Huatao, Pengfei Zhou, Rui Tan, Mo Li, and Guobin Shen. "Limu-bert: Unleashing the potential of unlabeled data for imu sensing applications." In Proceedings of the 19th ACM Conference on Embedded Networked Sensor Systems, pp. 220-233. 2021.

Questions

First, the authors should more clearly distinguish this work from existing state-of-the-art wearable motion foundation models.

Second, the authors should better clarify the technical novelty of the paper. The current contribution appears to mainly come from large-scale empirical analysis and new insights rather than new pretraining or fine-tuning methods. The authors should explicitly position the paper as a comprehensive empirical study and explain why the findings are significant for the wearable motion learning community.

Third, the authors should strengthen the experimental analysis by reporting system-level performance, including inference latency, memory usage, model size, and computational cost. Since wearable motion foundation models may be deployed on mobile or edge devices, these metrics are important for understanding practical feasibility. Such analysis would help answer whether the studied models are suitable for real-world wearable applications.

Fourth, the authors should include more representative self-supervised learning methods for IMU or wearable sensing in the comparison. This would help assess whether the conclusions about pretraining objectives are robust across a broader set of baselines.

Limitations

Yes

Final justification

Most of my concerns have been addressed. However, the novelty of the proposed method is still limited.

Formatting concerns

There are no paper formatting concerns.

3 comments
Authors · RebuttalOpenReview ↗
Rebuttal

Thank you for your thoughtful and thorough feedback. We appreciate your recognition of the breadth of our study and the insights it provides. We address each of your concerns and questions below and hope these clarifications better convey the paper’s contributions and merit a favorable reassessment.

 

W1&Q1: … more clearly discuss the differences between this work and existing state-of-the-art wearable motion foundation models …

Thank you for your comment regarding clarifying the positioning of previous wearable foundation models vs. our work. We would like to clarify that Inertia-1 does not aim to build the strongest wearable motion foundation model. Rather, our goal is to unify a research space that has, until now, been fragmented across datasets, sensor configurations, and objectives that were never designed to be compared against one another (Table 1 summarizes how prior studies each only cover a subset of the design choices we evaluate, whether that is sensors, placements, tasks, or configurations). Each prior wearable motion foundation model was built and validated within a single dataset, sensor configuration, or objective, offering no controlled view of how these choices interact.

In contrast, Inertia-1 evaluates 10 pretraining objectives under a shared protocol across a grid of experimental axes (sampling rate, window size, sensor modality, body placement -- Section 3.3, Table 7). This experimental setup allows us to isolate the effect of each individual design choice and glean insights systematically, as summarized in Section 4.3. Inertia-1’s contributions to this research space includes the following insights: we demonstrate that transferability across body placements and cooperation across multiple sensor streams can be measured (demonstrated via Section 4.4, see Figures 7 & 8). Thus, we position Inertia-1’s contribution as this unified, controlled empirical study to surface actionable insights for the wearable research community, rather than positing a new singular wearable foundation model.

 

W2&Q2: … the authors should better clarify the technical novelty of the paper … clarify the novelty beyond benchmarking

We appreciate the reviewer’s comments regarding better positioning the paper, and making clear the novelty beyond benchmarking model architectures. To clarify, we are not presenting a new training methods paper, rather, we present the first controlled, cross-objective, cross-task-family study of design choices for wearable motion foundation models at this scale, yielding practical findings that no prior study has produced. Under the NeurIPS guidelines, originality and significance of work is defined as

“not necessarily [requiring] introducing an entirely new method. Rather, a work that provides novel insights by evaluating existing methods, or demonstrates improved efficiency, fairness, etc. is also equally valuable.”

Under this criteria, we feel that Inertia-1 provides such a contribution: a unified experimental framework (Section 3, Table 7) that turns previously incomparable and isolated findings into a singular body of evidence in wearable motion representations.

Specifically, these findings include: (1) generalization across body placements, (2) cooperative gains from multiple sensor streams (Section 4.4), (3) how the benefit of self-supervision itself shifts across task families from activity recognition through gait to disease prediction (Section 4.1), and (4) how these results shift with scaling (Section 4.2). None of these findings follow from SSL-beats-supervised alone, and none of them are visible from any single prior study in isolation (Table 1). We will revise the abstract, introduction, and conclusion to lead explicitly with this framing so the contribution reads as what it is, rather than a new method. Prior work has largely centered on "which architecture or objective is best?" in isolation; our results show that the answer depends jointly on task granularity, sensing configuration, and data scale (Section 4.3), meaning a recipe validated on one placement, sensor, or task family cannot be assumed to transfer to another. This has immediate practical consequences for deployment: practitioners building wearable systems for a new placement, sensor suite, or clinical task can use these findings to anticipate which design choices will matter most, rather than re-running an isolated ablation from scratch on their own limited data.

Additionally, large‑scale physical activity surveillance and many contemporary HAR datasets rely primarily on wrist‑worn triaxial accelerometer data, while multimodal or multi‑placement datasets remain comparatively small and specialized [1][2][3]. Many other datasets might contain other body placements, sensors, or configurations, but are often too small to support pretraining (Section 1, Table 1). Our model is the first to study the transferability of pretraining on these large wrist-worn accelerometer corpora, and the downstream advantages such transfer poses for health related prediction tasks.

 

W3&Q3: … strengthen the experimental analysis by reporting system-level performance … whether the studied models are suitable for real-world wearable applications

While we note that the focus of our paper is not real time deployment, we provide some insights into the system-level performance of some of our models here. The encoder used throughout is our default configuration, 8.4 M trainable parameters. Measured on one A100-SXM4-40GB in fp32, encoder only, in eval mode: a single 30 s window costs 1.04 GFLOPs at 20 Hz and 0.25 GFLOPs at 1 Hz. Peak VRAM for a batch of 64 windows is 0.13 GB at 20 Hz and 0.07 GB at 1 Hz, and latency for that batch is 5.8 ms at 20 Hz against 2.0 ms at 1 Hz — 11.1 k versus 31.3 k windows per second, so roughly 2.8x more throughput. PatchTST is within a few percent of ART on all of these at matched input length. Critically, the processing time for a 30s window is a small fraction of the actual duration of the window. We see this as a benefit for any foundation models applied in realtime contexts as it demonstrates their ability to constantly process large amounts of data and provide valuable insights on the signal.

 

W4 & Q4: … include more representative self-supervised learning methods for IMU or wearable sensing in the comparison.

We thank the reviewer for this valuable suggestion. We have already implemented and begun pretraining two additional well-established wearable sensing methods, LIMU-BERT [4] and LSM-2 [5]. To ensure a fair comparison with the existing baselines, each method must be pretrained under the same data and compute settings, which requires approximately two days on four GPUs. We will report the results as soon as the runs are completed during the discussion period and update the manuscript accordingly.

 

References:

  1. Yuan, Hang, et al. "Self-supervised learning for human activity recognition using 700,000 person-days of wearable data." NPJ digital medicine 7.1 (2024): 91.
  2. Doherty, Aiden, et al. "Large scale population assessment of physical activity using wrist worn accelerometers: the UK biobank study." PloS one 12.2 (2017): e0169649.
  3. Mannini, Andrea, et al. "Activity recognition using a single accelerometer placed at the wrist or ankle." Medicine and science in sports and exercise 45.11 (2013): 2193.
  4. Xu, Huatao, et al. "Limu-bert: Unleashing the potential of unlabeled data for imu sensing applications." Proceedings of the 19th ACM Conference on Embedded Networked Sensor Systems. 2021.
  5. Xu, Maxwell A., et al. "Lsm-2: Learning from incomplete wearable sensor data." arXiv preprint arXiv:2506.05321 (2025).

 

We sincerely thank the reviewer once again for their time and constructive feedback. To support the community and enable future research, we remain committed to fully open-sourcing our research. We hope our detailed responses and the additional experiments have addressed your concerns, and we would be happy to answer remaining questions during the discussion period. We would be very grateful if you might consider raising your score and championing the paper in light of these updates.

Authors · CommentOpenReview ↗

Followup Response to Reviewer BMQ7

We thank the reviewer again for these helpful suggestions. We have now completed pretraining and evaluation of LIMU-BERT and LSM-2 under the same data, compute, and downstream evaluation protocol used for all existing methods, following each method’s original paper and released codebase as closely as possible while adapting only the interfaces necessary for our shared framework.

Model HAR_avg_auc FOG_avg_auc Disease_avg_auc
ViT 92.0 71.7 48.1
CNN 91.9 73.1 56.2
PatchTST 95.8 82.0 63.6
AR-Transformer 95.2 77.7 68.8
AR-GRU 94.7 82.7 64.7
DINO 89.9 77.9 68.8
SimCLR 90.4 84.3 67.2
SSL-Wearables 87.9 75.0 68.8
RelCon 93.3 86.2 61.7
SelfPAB 93.2 76.0 59.1
LSM-2 94.4 75.2 67.8
LIMU-BERT 92.3 73.9 63.2

These additional results support our original conclusion that no single pretraining objective performs uniformly best across all task families. Specifically, LIMU-BERT remains competitive on HAR and disease prediction but performs less strongly on FoG, while LSM-2 achieves strong HAR and disease-prediction performance, but is also comparatively weaker on FoG. Their relative rankings also continue to vary across HAR, FoG, and disease prediction, reinforcing our conclusion that no single pretraining objective performs uniformly best across all task families. We will add both methods, their implementation details, and the full per-dataset results to the revised manuscript. We thank the reviewer for prompting this addition, which has strengthened the breadth of our comparison and the evidence supporting our conclusions.

 

We sincerely thank the reviewer again for the constructive feedback and remain happy to answer any further questions during the discussion period. If these clarifications and additional experiments have addressed your concerns, we would be grateful if you would consider raising your score and supporting the paper in discussion.

Authors · CommentOpenReview ↗

Discussion Period Ending Soon: Follow-Up for Reviewer BMQ7

We would like to thank the reviewer again for your time and effort. In response to your latest comments, we have provided additional results and clarifications that we hope have addressed your remaining concerns.

Given there is only 1 days left in the discussion period, we wanted to kindly followup to check if the reviewer had seen our latest comment and whether there were any final clarifications that we can address. If the concerns of the reviewer are resolved and the reviewer is convinced of the novelty and completeness of our work, we'd be grateful if the reviewer could update your review and score to reflect that, so we know that our response has been seen.

Once again, many thanks for your time and dedication to the review process, we are extremely grateful.

Reviewer Cr43OpenReview ↗
Rating
5/6
Confidence
4/5
Quality
4/4
Clarity
4/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper presents a comprehensive empirical study of foundation models for wearable motion sensing. The authors compare supervised and self-supervised pretraining strategies using large-scale wearable datasets, evaluating both general-purpose self-supervised methods and wearable-specific approaches. The pretrained models are assessed on 10 downstream datasets spanning human activity recognition (HAR), freezing-of-gait (FoG) detection, and disease prediction tasks, providing a broad evaluation of transferability. The paper also investigates several practical design choices, including model scaling, pretraining dataset size, signal duration, accelerometer sampling frequency, the addition of other signals and different sensor placements. Rather than proposing a new learning method, the paper aims to provide a set of empirical findings and practical recommendations for developing wearable motion foundation models.

Strengths and weaknesses

Strengths

  • The paper addresses a relevant topic as foundation models for wearable sensing continue to gain interest
  • The experimental evaluation is comprehensive, covering numerous pretraining methods, downstream tasks, and practical design choices
  • Evaluating transfer performance on ten downstream datasets demonstrates good generalizability beyond the pretraining datasets
  • The comparison between learning objectives provides useful insights, showing that no single approach consistently dominates across all tasks
  • The manuscript is clearly written, well structured, and easy to follow despite the large number of experiments

Weaknesses

  • The work is primarily an empirical benchmark, and while the reported trends are convincing, the discussion could provide more insight into why certain design choices or pretraining strategies outperform others
  • Some practical recommendations are presented without substantial discussion of the underlying rationale, leaving readers with empirical observations rather than explanatory insights
  • Many conclusions are based on differences in AUROC across downstream tasks, but the paper does not report confidence intervals, statistical significance tests, or variability across multiple training runs. Given that several reported improvements appear modest, some estimate of statistical uncertainty would help readers assess whether observed differences are meaningful.
Questions
  • Table 3 presents results across many HAR datasets, making it difficult to identify the strongest overall model. Including an aggregate statistic, such as the mean AUROC or average rank across datasets, would improve readability and facilitate comparison between methods
  • Since the paper aims to provide practical guidance, a more explicit discussion of why general-purpose self-supervised methods often outperform wearable-specific objectives would strengthen the practical takeaways. Even if no definitive explanation exists, further discussing possible factors would help readers interpret the results.
  • In the experiments evaluating accelerometer sampling frequencies, the authors compare 1, 5, and 20 Hz. While these results are interesting, the motivation for selecting these specific frequencies is not entirely clear. It would be helpful to relate these choices to common wearable hardware configurations, battery constraints, or prior literature. Additionally, the observation that 5 Hz performs particularly well for the FoG task deserves further discussion.
  • Section 4 not only presents experimental results but also interprets them and extracts practical lessons. Renaming this section to "Results and Discussion" would be a better match. Similarly, Section 5 could be named Conclusion and Future Work or something similar
Limitations

While the scaling studies are valuable, the discussion could more explicitly address the practical trade-offs between performance improvements and computational cost. This would help to decide when increasing model size or pretraining data is worth it.

Final justification

I recommend Accept. The authors addressed my main concerns regarding metric reporting and uncertainty quantification, and provided additional analyses and justification for how design choices affect performance.

Formatting concerns

Nothing to report

4 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We thank the reviewer for their constructive feedback and positive evaluation of our work. We sincerely appreciate your recognition of the clarity, relevance, and comprehensiveness of our exploration. We hope the detailed responses below address your concerns.

 

Q1: … Including an aggregate statistic …

We originally emphasized per-dataset results because aggregate metrics can obscure task-specific variation. However, we agree that an overall summary improves readability and report average performance and rank below.

HAR AUC FoG AUC Disease AUC Avg. Rank
ViT 92.03 71.70 48.10 7.64
CNN 91.87 73.10 56.16 6.96
PatchTST 95.84 82.03 63.64 3.93
AR-Transformer 95.21 77.70 68.82 3.98
AR-GRU 94.73 82.67 64.70 4.61
DINO 89.92 77.93 68.82 5.17
SimCLR 90.43 84.30 67.20 4.53
SSL-Wearables 87.89 75.00 68.84 6.04
RelCon 93.31 86.23 61.74 5.46
SelfPAB 93.22 75.97 59.14 6.68

The aggregate results remain strongly task-dependent. PatchTST and AR-Transformer lead on HAR, RelCon on FoG, and SSL-Wearables and AR-Transformer on disease prediction. We believe these results further support our claim in the paper that no single pretraining objective performs uniformly best across all downstream task families.

 

W2: … recommendations are presented without … rationale…

We deeply agree with the reviewer that the recommendations would benefit from mechanistic explanations. Below we give two such analyses, and we remain happy to address any remaining concerns that the reviewer might have during the discussion period.

(i) Low-rate HAR robustness

Using WISDM, we compare AR-Transformer pretrained at 20 Hz and 1 Hz. We report activity intensity quantified by gravity-removed acceleration power [1] and AUROC stratified by different levels of activity intensity.

activity group intensity AUROC 20 Hz AUROC 1 Hz (1−20 Hz)
static (sitting, standing, typing, writing) 3.3–4.4 92.6 93.2 +0.7
hand/eating (6 activities) 4.6–74 89.8 87.3 −2.5
high-cadence (6 activities) 25–478 95.6 92.8 −2.8
locomotion (walking, stairs) 116–160 97.4 94.0 −3.4
macro (all 18 activities) 93.2 91.2 −2.0

Only near-stationary activities improve at 1 Hz, and the gain from 1 Hz to 20 Hz increases with activity intensity. Even for more dynamic activities, however, the reduction is only 2.5–3.4 AUROC points. This explains why aggregate HAR remains competitive after aggressive downsampling: posture-driven classes require little high-frequency information, while dynamic classes retain substantial discriminative signals.

(ii) Short-event FoG sensitivity

Section 4.3 attributes the stronger FoG performance of time-domain models to their preservation of precise temporal structure. We now provide a quantitative mechanism on the FoGTurning dataset. Spectrogram methods impose a fixed temporal granularity through their FFT window and hop size. For 30 s inputs, Self-PAB uses 3.2 s frames and averages them into the final embedding. While the median episode lasts 3.0 s, more than half of the events are shorter than one frame and may be blended with surrounding gait. We therefore expect Self-PAB to perform worst on episodes below 3.2 s. We hold evaluation fixed across encoders: identical 30 s, 20 Hz triaxial inputs, frozen backbones, linear probes, and subject-grouped folds. Duration bins follow Self-PAB’s 3.2 s frame length.

Encoder domain overall episode <3.2 s 3.2–6.4 s 6.4–15 s >15 s
Self-PAB time-frequency 0.705 0.356 0.537 0.733 0.781
ART time 0.918 0.854 0.834 0.831 0.981
PatchTST time 0.923 0.820 0.814 0.900 0.977
ARG time 0.908 0.821 0.841 0.803 0.975
positive windows 1687 76 328 331 952

Self-PAB’s AUROC increases monotonically with episode duration, from 0.356 for events shorter than one frame to 0.781 for events longer than 15 s, whereas the time-domain encoders remain strong across all bins. This directly supports our claim that time-domain modeling better preserves brief, transient FoG patterns. The fixed spectrogram granularity disproportionately weakens short events by mixing them with adjacent gait, while time-domain models retain these local signatures more effectively. Self-PAB remains weaker even for longer episodes, so frame length does not explain the entire gap, but it provides a clear mechanism for the pronounced deficit on short FoG events.

 

Q3: … relate these choices to common wearable hardware … or prior literature…

We use 20 Hz as a practical high-resolution reference: prior work shows that most wearable-motion energy lies below 10 Hz and that reducing 100 Hz signals to approximately 20 Hz substantially lowers storage and computation with minimal performance loss [2]. We use 1 Hz to represent per-second actigraphy summaries and 5 Hz as an intermediate low-power regime [6]. Prior work shows that sampling rate materially affects computation and power in continuous recognition [3,7], motivating evaluation between summary-level and full-resolution sensing.

 

W1&Q2: … why certain … pretraining strategies outperform others.

We agree that discussing why general-purpose SSL methods often outperform wearable-specific objectives would strengthen the practical takeaways. While our results do not establish a definitive cause, two factors may contribute: general-purpose methods often benefit from mature architectures and optimization recipes, whereas wearable-specific objectives may encode assumptions tailored to particular sampling rates, windows, or sensing configurations that transfer less robustly across heterogeneous settings. We emphasize that our comparison evaluates robustness under a shared protocol, not each method’s task-specific optimum. Because wearable-specific methods often use different input lengths, sampling rates, channel configurations, and tuning procedures, reproducing every original setting would undermine a controlled comparison. We therefore match the main training choices and interpret the results as evidence of transfer under common settings, not universal superiority.

 

W3: … paper does not report confidence intervals …

We fully agree that statistical uncertainty would strengthen the paper. We bootstrap the test set and aggregate across target datasets. Given space constraints, we report analyses for the central claims below and will be happy to provide additional comparisons during discussion.

HAR AUC with 95% CI

A A_ci B B_ci p
Higher Sampling Rate ART @ 20 Hz [95.2-95.4] ART @ 1 Hz [91.2-91.4] <0.01
- ART @ 20 Hz [95.2-95.4] ART @ 5 Hz [93.4-93.7] <0.01
- ART @ 5 Hz [93.4-93.7] ART @ 1 Hz [91.2-91.4] <0.01
Window Length Effects ART @ 30 s [95.2-95.4] ART @ 10 s [92.6-92.8] <0.01
- ART @ 30 s [95.2-95.4] ART @ 60 s [90.2-90.4] <0.01
Triaxial vs. Uniaxial ART triaxial [95.2-95.4] ART uniaxial [91.3-91.5] <0.01
SSL vs. Supervised ART [95.1-95.3] CNN [91.8-92.1] <0.01

FOG AUC with 95% CI

A A_ci B B_ci p
Higher Sampling Rate ART @ 20 Hz [78.4-81.6] ART @ 1 Hz [66.9-70.7] <0.01
- ART @ 20 Hz [78.4-81.6] ART @ 5 Hz [80.5-83.4] 0.085
- ART @ 5 Hz [80.5-83.4] ART @ 1 Hz [66.9-70.7] <0.01
Window Length Effects ART @ 30 s [78.4-81.6] ART @ 10 s [78.9-82.0] 0.680
- ART @ 30 s [78.4-81.6] ART @ 60 s [86.2-89.9] <0.01
Triaxial vs. Uniaxial ART triaxial [78.4-81.6] ART uniaxial [76.4-79.8] 0.043
SSL vs. Supervised ART [76.0-79.4] CNN [71.4-74.7] <0.01

Disease AUC with 95% CI

A A_ci B B_ci p
Higher Sampling Rate ART @ 20 Hz [61.6-76.0] ART @ 1 Hz [51.0-62.0] 0.012
- ART @ 20 Hz [61.6-76.0] ART @ 5 Hz [50.3-58.5] <0.01
Window length effects ART @ 30 s [61.6-76.0] ART @ 10 s [58.8-67.5] 0.213
- ART @ 30 s [61.6-76.0] ART @ 60 s [55.2-69.3] 0.222
Triaxial vs. Uniaxial ART triaxial [61.6-76.0] ART uniaxial [64.1-71.3] 0.756
SSL vs. Supervised ART [61.6-76.0] CNN [50.7-56.8] <0.01

The analyses support most central claims. For HAR, performance increases significantly with sampling frequency. The effect of window length is task-dependent: HAR peaks at 30s, whereas FoG only improves significantly from 30s to 60s. Disease prediction shows no significant window-length differences. Triaxial input significantly improves HAR and FoG but not disease prediction; we will revise this claim to state that triaxial input benefits most evaluated task families. We thank the reviewer for drawing attention to the FoG result at 5 Hz. As shown in the table, performance at 5 Hz is numerically above 20 Hz but not significantly different, indicating a plateau at 5 Hz and above rather than a meaningful advantage. We will add confidence intervals and clarify this interpretation.

 

Q4: Renaming

We appreciate this suggestion and the meticulous reading and will rename the sections accordingly.

 

References:

  1. Bao, et al. Activity recognition from user-annotated acceleration data. 2004.
  2. Yamane, et al. Effects of sampling frequency on human activity 2025.
  3. Yan, et al. Energy-efficient continuous activity recognition.. 2012.
  4. Moore, et al. Ambulatory monitoring of freezing of gait in Parkinson's disease. 2008.
  5. Bächlin et al. Wearable assistant for Parkinson's disease patients.. 2010.
  6. Yamane, et al. Effects of sampling frequency on human activity recognition.. 2025.
  7. Bieber, et al. Low sampling rate for physical activity recognition. 2014.

 

We sincerely thank the reviewer again for their time and constructive feedback. We remain committed to fully open-sourcing this work and hope our responses and additional experiments have addressed your concerns. We would be happy to answer any remaining questions during the discussion period and would be very grateful if you might consider raising your score and championing the paper in light of these updates.

Reviewer Cr43 · CommentOpenReview ↗

Thank you for addressing my concerns. Some additional points:

Q1: Including an aggregate statistic

I appreciate the addition of aggregate metrics across tasks. If possible, I would suggest considering this aggregate summary as the main comparison table, with the more detailed per-dataset results moved to the appendix. Including confidence intervals or uncertainty estimates alongside these aggregate results would further improve interpretability.

W2: Low-rate HAR robustness

The observation that 1 Hz slightly outperforms 20 Hz for near-static activities is interesting. Since the improvement is relatively small and may be within the uncertainty of the estimate, it could be helpful to understand whether this reflects meaningful differences in signal content, or whether other factors (e.g., reduced number of input samples, input representation, model optimization, or architecture effects) may also contribute to this trend. I would suggest avoiding strong conclusions without further analysis of these potential factors.

W3: Lack of confidence intervals

Thank you for providing bootstrap confidence intervals for the main comparisons. For clarity, I suggest reporting additional details about the uncertainty analysis, including the number of resamples and the statistical testing used. It would also improve readability to report the point estimate together with its confidence interval (e.g., mean (CI-low - CI-high)) rather than reporting confidence intervals alone.

When revising the manuscript, I encourage you to integrate these points cohesively throughout the text, particularly by clarifying how this work contributes to the understanding of motion foundation models beyond an empirical comparison of existing methods, as also highlighted by other reviewers. Given the comprehensive experimental evaluation, it is important that the main claims and lessons learned are supported with clear interpretation and appropriate methodological rigor.

Authors · CommentOpenReview ↗

Response to Reviewer Cr43

Thank you for the thoughtful follow-up and for these helpful suggestions. We agree that the aggregate comparison, uncertainty analysis, and mechanistic interpretation will improve the clarity and rigor of our results, and we will integrate them more clearly into the revised manuscript.

 

Q1: Aggregate comparison table:

Thank you for this suggestion. We agree that the aggregate summary provides a clearer high-level comparison across methods. In the revision, we will promote the task-family-level mean AUROC and average-rank summary to the main text and move the full per-dataset results to the appendix. We will also report each aggregate point estimate together with its uncertainty where applicable, while retaining the per-dataset table for detailed inspection.

 

W2: Low-rate HAR robustness

We agree that the small improvement for near-static activities should not be interpreted as evidence that 1 Hz is intrinsically superior. Our intended conclusion is only that near-static activities are relatively insensitive to aggressive downsampling, whereas dynamic activities degrade more clearly.

activity group intensity AUROC 20 Hz AUROC 1 Hz Δ (1 − 20 Hz), 95% CI
static (sitting, standing, typing, writing) 3.3–4.4 92.6 93.2 +0.7 [−0.1, +1.5]
hand / eating (6 activities) 4.6–74 89.8 87.3 −2.5 [−4.0, −1.3]
high-cadence (6 activities) 25–478 95.6 92.8 −2.8 [−4.0, −1.8]
locomotion (walking, stairs) 116–160 97.4 94.0 −3.4 [−4.9, −2.1]

We recompute the change in performance between 1Hz and 20Hz models with 95% bootstrap CIs over the 51 subjects. The results show that non-static activity recognition significantly degrades in the 1Hz models compared to 20Hz models, while the difference is subtle (Δ overlaps 0) on static activities. The main supported finding is that reducing the sampling rate from 20 Hz to 1 Hz causes little degradation for near-static activities but a substantially larger reduction for locomotion and other dynamic activities. We will include CIs and significance analysis during revision to avoid misinterpretation of these small differences.

Authors · CommentOpenReview ↗

Response to Reviewer Cr43 (Continuation)

W3: Uncertainty-analysis details

We agree that the statistical procedure should be described more explicitly. We use a percentile bootstrap with 2,000 replicates. In each replicate, we resample the test rows with replacement and recompute the evaluation metric.

The 95% confidence interval is defined by the 2.5th and 97.5th percentiles of the bootstrap estimates. For model comparisons, we use a paired percentile-bootstrap significance test via confidence-interval inversion: both models are evaluated using the same bootstrap resample, and the distribution of their metric difference is used to obtain a two-sided p-value. This test is suitable because it directly estimates uncertainty in the paired performance difference without requiring AUROC estimates to follow a normal distribution.

Following the reviewer’s suggestion, we have revised our CI tables to report point estimates as well:

HAR AUC with 95% CI

Comparison A B p-value
Higher sampling rate ART @ 20 Hz: 95.3 (95.2–95.4) ART @ 1 Hz: 91.3 (91.2–91.4) <0.01
Higher sampling rate ART @ 20 Hz: 95.3 (95.2–95.4) ART @ 5 Hz: 93.6 (93.4–93.7) <0.01
Higher sampling rate ART @ 5 Hz: 93.6 (93.4–93.7) ART @ 1 Hz: 91.3 (91.2–91.4) <0.01
Window-length effects ART @ 30 s: 95.3 (95.2–95.4) ART @ 10 s: 92.7 (92.6–92.8) <0.01
Window-length effects ART @ 30 s: 95.3 (95.2–95.4) ART @ 60 s: 90.3 (90.2–90.4) <0.01
Triaxial vs. uniaxial ART triaxial: 95.3 (95.2–95.4) ART uniaxial: 91.4 (91.3–91.5) <0.01
SSL vs. supervised ART: 95.2 (95.1–95.3) CNN: 92.0 (91.8–92.1) <0.01

FoG AUC with 95% CI

Comparison A B p-value
Higher sampling rate ART @ 20 Hz: 80.0 (78.4–81.6) ART @ 1 Hz: 68.8 (66.9–70.7) <0.01
Higher sampling rate ART @ 20 Hz: 80.0 (78.4–81.6) ART @ 5 Hz: 82.0 (80.5–83.4) 0.0850
Higher sampling rate ART @ 5 Hz: 82.0 (80.5–83.4) ART @ 1 Hz: 68.8 (66.9–70.7) <0.01
Window-length effects ART @ 30 s: 80.0 (78.4–81.6) ART @ 10 s: 80.5 (78.9–82.0) 0.6800
Window-length effects ART @ 30 s: 80.0 (78.4–81.6) ART @ 60 s: 88.1 (86.2–89.9) <0.01
Triaxial vs. uniaxial ART triaxial: 80.0 (78.4–81.6) ART uniaxial: 78.1 (76.4–79.8) 0.0430
SSL vs. supervised ART: 77.7 (76.0–79.4) CNN: 73.1 (71.4–74.7) <0.01

Disease AUC with 95% CI

Comparison A B p-value
Higher sampling rate ART @ 20 Hz: 68.8 (61.6–76.0) ART @ 1 Hz: 56.5 (51.0–62.0) 0.0117
Higher sampling rate ART @ 20 Hz: 68.8 (61.6–76.0) ART @ 5 Hz: 54.4 (50.3–58.5) <0.01
Window-length effects ART @ 30 s: 68.8 (61.6–76.0) ART @ 10 s: 63.2 (58.8–67.5) 0.2131
Window-length effects ART @ 30 s: 68.8 (61.6–76.0) ART @ 60 s: 62.3 (55.2–69.3) 0.2224
Triaxial vs. uniaxial ART triaxial: 68.8 (61.6–76.0) ART uniaxial: 67.7 (64.1–71.3) 0.7564
SSL vs. supervised ART: 68.8 (61.6–76.0) CNN: 53.8 (50.7–56.8) <0.01

We will revise the Results and Discussion to organize the evidence around the paper’s main insights rather than individual experiments, clearly distinguish confirmatory findings from new conclusions, and ensure that each takeaway is supported by statistical evidence and appropriate interpretation.

 

We sincerely thank the reviewer again for the thorough reading of our paper and for the thoughtful, constructive suggestions. These comments have helped us improve both the methodological rigor and presentation of the work. We hope that our additional analyses and planned revisions have fully addressed the remaining concerns. If so, we would be very grateful if the reviewer could support the paper during the discussion.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Missing a submission?

Loading the discussion…