Stochastic Grouping Conformal Prediction for Effective Subgroup Reliability
Meihui Zhong, Wenxin Tai, Ting Zhong, Fan Zhou
NeurIPS 2026
TL;DR. We present a fairness-aware conformal prediction method that improves coverage for clinically meaningful subgroups without relying on predefined sensitive groups.
Abstract. Conformal prediction offers a distribution-free coverage guarantee, making it especially attractive for clinical applications. Standard conformal prediction, however, provides such guarantees only at the population level, and its prediction sets can exhibit coverage disparities across clinically important subgroups. A natural remedy is to calibrate within predefined groups. However, this can require access to sensitive subgroup attributes and is prone to a worst-group bottleneck: protecting the most difficult subgroup can inflate prediction sets for all, increasing cognitive burden on decision makers. To this end, we propose Stochastic Grouping Conformal Prediction (SGCP), a conformal framework for subgroup-reliable uncertainty quantification. It learns a stochastic grouping map that allows each sample to draw calibration information from others with similar calibration behavior, yielding a local score law that boosts reliability across subpopulations. We prove that SGCP retains the standard coverage guarantee. Experiments on synthetic and real-world benchmarks show that it consistently reduces subgroup coverage gaps while achieving smaller or comparable prediction set sizes relative to existing baselines.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:48 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
This paper proposes a fairness-aware conformal prediction method for clinical applications. The reviewers generally found the paper to be well-written and well-motivated and the experiments to be sufficiently thorough. Prior to the author/reviewer discussion period, reviews were slightly mixed (1 accept, 1 borderline accept, 1 borderline reject) although leaning toward acceptance. After the author/reviewer discussion period, reviews unanimously favored acceptance (2 accept, 1 borderline accept). In particular, the authors adequately addressed reviewer concerns regarding novelty, interpretability, and robustness. I am recommending that this paper be accepted.
Final justification
My meta-review already includes my updated justification.
- Final justification
- My meta-review already includes my updated justification.
Read meta-review
Meta-review
This paper proposes a fairness-aware conformal prediction method for clinical applications. The reviewers generally found the paper to be well-written and well-motivated and the experiments to be sufficiently thorough. Prior to the author/reviewer discussion period, reviews were slightly mixed (1 accept, 1 borderline accept, 1 borderline reject) although leaning toward acceptance. After the author/reviewer discussion period, reviews unanimously favored acceptance (2 accept, 1 borderline accept). In particular, the authors adequately addressed reviewer concerns regarding novelty, interpretability, and robustness. I am recommending that this paper be accepted.
- Rating
- 5/6
- Confidence
- 2/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper introduces Stochastic Grouping Conformal Prediction (SGCP) to address the critical limitation of standard conformal prediction, which guarantees uncertainty only at the population level and often fails to provide reliable coverage for minority subgroups. Instead of relying on explicit sensitive attributes like race or gender to calibrate subgroups separately, which can lead to inflated, uninformative prediction sets due to limited data, SGCP learns a latent structure that automatically organizes samples based on their inherent calibration behavior. When processing a new patient, the model stochastically maps the patient across these latent components, allowing for flexible and shared calibration. This approach mathematically preserves the standard overall coverage guarantee while empirically boosting the reliability of predictions for underrepresented groups without requiring demographic data.
Strengths and weaknesses
Strengths High Clinical Practicality (Privacy-Preserving Fairness): The motivation to achieve subgroup reliability without requiring explicit access to sensitive attributes (e.g., race, gender, socioeconomic status) is highly commendable. In real-world clinical settings, demographic data is often incomplete, noisy, or legally restricted. SGCP provides an elegant, privacy-preserving workaround by organizing samples based on their inherent "calibration behavior" rather than predefined labels.
Elegant Mitigation of the Worst-Group Bottleneck: Standard group-conditional conformal prediction often suffers from inflated prediction sets due to limited sample sizes in minority groups. SGCP addresses this structural bottleneck beautifully. By introducing a stochastic grouping map, the framework allows flexible sharing of calibration information across latent components, effectively balancing subgroup reliability with prediction set efficiency (reducing cognitive burden for clinicians).
Weaknesses The paper promotes "subgroup reliability" as its primary contribution. However, the theoretical proof provided only guarantees marginal (population-level) validity (Eq. 1), which is the exact same guarantee provided by standard conformal prediction. The absence of a formal mathematical proof for finite-sample conditional or subgroup-level coverage creates a significant gap between the paper's conceptual narrative and its mathematical substance.
The mechanism relies on mapping patients to a "latent calibration structure." In medical decision-making, transparency is critical. If a patient is assigned an unusually large prediction set, a clinician has no way to interpret why or to understand what specific "latent group" the patient was probabilistically assigned to. This black-box grouping limits the trustworthiness of the uncertainty quantification.
Questions
While the paper proves marginal coverage, standard conformal prediction already achieves this. Is it possible to provide a theoretical bound (even a relaxed or asymptotic one) for the coverage guarantee specifically within the learned latent subgroups?
In a clinical deployment, how can a medical professional interpret the latent groups?
The framework relies on drawing calibration information from "a small set of latent calibration components." How is the optimal number of these components structurally determined, and what happens if this hyperparameter severely mismatches the true underlying heterogeneity of the patient population?
Limitations
No limitations addressed.
Final justification
I thank the authors for the detailed rebuttal. The clarification regarding Proposition 3 adequately addresses my main theoretical concern about finite-sample subgroup bounds. Furthermore, the post-hoc analysis on the MIMIC-IV dataset and the explanation of K as a resolution parameter parameter provide sufficient reassurance regarding interpretability and robustness. The authors successfully addressed my concerns, and I will raise my score accordingly.
Formatting concerns
,
1 comment
- Rating
- 5/6
- Confidence
- 4/5
- Quality
- 4/4
- Clarity
- 4/4
- Significance
- 3/4
- Originality
- 4/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
Split conformal prediction is a method for taking a classifier and for each input producing a set of predictions that contains the true label with a high probability. Given data and labels and a classifier that predicts class probabilities, conformal prediction produces a prediction set with a user specified coverage level . Simplifying a bit, the true label is in the prediction set with probability . With split conformal prediction the data is split into training and validation datasets to compute , and a calibration dataset to compute .
Conformal Prediction (CP) typically works at the population level, that is for the entire dataset. The challenge with medical data is that there are usually subpopulations that are underrepresented in the data, but important when providing healthcare. Using a population CP function for computing the prediction set typically does not do well on subpopulations. On the other hand, building individual prediction set functions for each subpopulation also doesn’t do well either, since the subpopulations are underrepresented in the data and typically not large enough to compute a useful function for computing prediction sets for each subpopulation.
The paper proposes an algorithm called Stochastic Grouping Conformal Prediction (SGCP) for producing better prediction sets using CP. It does this for each sample by associating other samples from the population that have similar calibration behavior and using this group as the basis for computing the CP prediction function . Similar points for the group are determined using the nonconformity score . For a point x with label y, the nonconformity score is .
The key idea is to introduce for each sample what the paper calls latent calibration components , , and to compute weight so that the sum can be used to compute the prediction set using the nonconformity score .
The paper evaluates the SGCP on both synthetic and real word data and has a careful comparison of SGCP against other methods for computing CP.
The paper also contains multiple ablation studies.
Strengths and weaknesses
Strengths
• Stochastic Group Conformal Prediction (SGCP) is a promising approach for the important problem of providing uncertainty estimates for subpopulations that may be underrepresented in a larger population.
• SGCP is evaluated on multiple real-world datasets (Nursery, MIMIC-IV, and BACH) and a synthetic dataset (a cardiopulmonary diagnosis dataset)
• The paper contains careful benchmarks against the following competing algorithms: AFCP [29], Clustered CP [8], FaReG [27], RLCP [12], marginal CP, Partial Equalized [20], and Exhaustive Equalized CP.
• The paper is well written and easy to follow, even if you are not familiar with CP.
• The proofs in Appendix A seem reasonable to me, but I did not check them carefully.
• Algorithm 2 is clear.
• Related work was clear.
Weaknesses
• There are no major weaknesses.
• I would have welcomed an appendix with a more intuitive explanation of how the latent calibration components were computed with a longer technical description of how they are computed than is what given in lines of 165-190 of the ms.
• The paper is positioned as providing a CP algorithm for working with underrepresented populations in healthcare. There were two real world datasets (MIMIC-IV and Bach) and one synthetic dataset in healthcare. The paper would have been stronger with another medical dataset, but given the work required to include another dataset, this is a minor weakness.
Questions
-
As mentioned, I would have welcomed an appendix with a more intuitive explanation of how the latent calibration components were computed with a longer technical description of how they are computed than is what given in lines of 165-190 of the ms.
-
I would have also welcome the evaluation of the algorithm on another biomedical dataset.
Limitations
Yes
Final justification
I have read through the various reviews and rebuttals and I'm comfortable with my original scores. I'm was happy to see the additional information provided by the authors in their responses and that there is is emerging consensus between my review and the review by Reviewer 7tHE.
Formatting concerns
NA
3 comments
Rebuttal
We thank you for the careful and positive assessment, and for recognizing the breadth of the experiments and the clarity of the presentation. The two suggestions are well taken. Below, we explain each point in more detail.
W1&Q1. What exactly do the latent calibration components learn?
A1. We realize that the term `latent calibration component' may make the learned object sound more abstract than it really is. The short answer is: SGCP learns reusable score distributions, not latent patient clusters. Each component describes one recurring pattern of true-label nonconformity scores, and the router determines how those patterns should be combined for the current sample.
-
The target object. Let . If the patient-conditional score CDF were known, it would tell us whether a raw score is ordinary or unusually large for patient . Estimating a separate CDF at every is statistically infeasible. SGCP therefore learns the structured approximation .
-
The two learned objects. Each is an entire CDF of true-label nonconformity scores, including its location, dispersion, and tail behavior. It is neither a cluster center nor a component-specific conformal cutoff. The weight specifies how much score-law regime contributes to the local CDF of sample , with . Put simply, describes what score behavior can be reused, while describes how much that behavior matters for this sample. A sample may therefore borrow calibration evidence from several regimes instead of being assigned one latent group label.
-
How they are learned. The stochastic router learns from calibration-relevant score behavior rather than generic feature proximity. It maps the backbone representation to a Gaussian latent state, softly matches latent draws to learned prototypes, and averages their assignments. The three training terms have distinct roles. Rank uniformization trains the component transforms to act as percentile maps. The local likelihood makes their mixture explain the observed true-label scores. The grouping regularizer prevents collapsed or uniformly diffuse responsibilities. Posterior averaging then preserves genuine ambiguity between regimes while stabilizing the weights. In the implementation used throughout our experiments, once the router has been learned, the final component law is estimated on the held-out training-side split as a responsibility-weighted empirical CDF. Writing
Thus, every training score contributes fractionally to each component according to its responsibility.
-
Why this improves subgroup reliability. At test time, converts each candidate-label score into a patient-specific percentile. When it approximates well, true-label scores from different subgroups are placed on a comparable percentile scale. One pooled conformal cutoff can then carry a similar meaning across the population. This is how SGCP improves subgroup reliability without predefined sensitive groups calibration.
We will provide a more intuitive and detailed explanation of the latent calibration components in the appendix of the revised version.
W2&Q2. Another biomedical benchmark
A2. Thank you for this suggestion.
To be honest, during the development of this work, we had already conducted experiments on two additional biomedical datasets, HAM10000 [1] and MIMIC-CXR [2]. We did not report additional benchmarks because we considered the four datasets sufficiently representative of the intended evaluation scope. This choice is also consistent with closely related work, which commonly evaluates on three or four datasets.
Since you specifically asked for another biomedical benchmark, we are very happy to share both existing results here.
HAM10000 is a public seven class dermoscopic lesion dataset with 10,015 images. Its metadata include sex, age, and lesion site, allowing us to evaluate both individual sensitive attributes and their intersections under the same protocol as the other datasets.
At nominal coverage , the results are:
| Method | Coverage | AvgSize | Intersection CovGap |
|---|---|---|---|
| Marginal CP | 90.25±0.88 | 1.351±0.052 | 7.3±0.62 |
| Partial | 90.24±0.90 | 1.34±0.05 | 7.4±0.54 |
| AFCP | 90.44±0.86 | 1.64±0.10 | 6.2±0.49 |
| FaReG | 93.02±1.09 | 1.93±0.15 | 8.0±1.09 |
| SGCP | 90.30±0.88 | 1.355±0.053 | 5.99±0.84 |
On HAM10000, SGCP stays close to nominal coverage and achieves the lowest intersectional CovGap. Its average set size is nearly identical to Marginal CP and Partial and substantially smaller than AFCP and FaReG. The lower CovGap is therefore not obtained by uniformly enlarging the prediction sets.
MIMIC-CXR is a large scale clinical chest radiograph dataset accompanied by demographic and encounter level metadata. It served as our second imaging benchmark for thoracic disease prediction and for intersectional subgroup analyses based on the available patient level attributes.
The results are below, and we see the same efficiency–reliability balance:
| Method | Coverage | AvgSize | Intersection CovGap |
|---|---|---|---|
| Marginal CP | 90.27±0.70 | 1.39±0.34 | 1.24±0.34 |
| Partial | 90.49±0.63 | 1.41±0.02 | 1.35±0.33 |
| AFCP | 90.31±0.86 | 1.49±0.02 | 1.14±0.32 |
| FaReG | 93.78±0.59 | 1.62±0.03 | 3.78±0.59 |
| SGCP | 90.25±0.72 | 1.39±0.02 | 1.21±0.33 |
Results. These two experiments broaden the evaluation to dermatology and chest radiography and show that the behavior observed in the submitted benchmarks is not limited to one clinical task or modality.
We will add this additional evaluation to the appendix of the revised manuscript.
[1] P. Tschandl, C. Rosendahl, and H. Kittler, “The ham10000 dataset, a large collection of multi-source dermatoscopic images of common pigmented skin lesions,” Scientific Data, vol. 5, no. 1, p. 180161, 2018.
[2] A. Johnson, T. Pollard, R. Mark, S. Berkowitz, and S. Horng, “MIMIC-CXR Database,” PhysioNet, Sep. 2019, version 2.0.0. [Online].
Again, we appreciate your recognition of the paper's contributions and hope our responses have fully addressed your questions. We hope these clarifications solidify your support for our paper, and we are, of course, happy to address any remaining concerns. Thank you!!!
Thank you for adding this additional material to the appendix of the revised manuscript.
Thank you for adding this additional material to the appendix of the revised manuscript. This addresses my concerns and suggestions. I think this will be helpful to your readers.
We are very happy that the additional material has addressed your concerns.
We are very happy that the additional material has addressed your concerns. Should you have any further suggestions, we would be most grateful if you could add them to your review so that we may see them. Thank you once again for your thoughtful comments and generous support of our work. It means a lot to us :)
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 2/4
- Originality
- 2/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The authors seek to improve the subgroup fairness of using conformal prediction for clinical prediction tasks. They propose a framework called stochastic grouping conformal prediction, which uses a weighted combination of latent components to form local scores that each sample is calibrated to. The authors then validate their framework against other baselines in a set of clinical task benchmarks, with demographic features forming subgroups.
Strengths and weaknesses
Strengths:
- Fairly thorough empirical result benchmark: 4 clinical task datasets and 7 baseline methods. Standard deviation is reported with 20 randomized runs.
- Clean and interpretable figures.
- Detailed methodological motivations.
Weaknesses:
- Generalization Concern: Lacking experiments testing out-of-domain generalization capabilities of their method, and other robustness studies. A key feature of subgroup fairness in the clinical setting is how subgroup definitions and characteristics may differ across hospitals and other clinical settings. Thus, I would highly recommend a method focusing on subgroup fairness to evaluate at least one dataset on an out-of-domain dataset and test whether the learned latent components and conformal prediction performances transfer.
- Lesser novelty: Grouping samples by calibration behavior is interesting, but SGCP appears closely related to prior work on nonconformity-score-based grouping [1] and latent representation-based subgroup discovery [2]. The paper would benefit from a clearer explanation of how SGCP differs from these methods and what is specifically novel. Since there is no dedicated related-work section, this distinction should be made more explicit in the main text.
- Interpretability Tradeoff: SGCP’s latent components may improve calibration for data-sparse subpopulations, but they are difficult to interpret and validate. Unlike predefined-group methods, the source of each calibration adjustment is not transparent, which may limit clinical trust and auditability. Figure 3 shows distinct component distributions, but the paper does not explain whether they correspond to meaningful factors such as prediction difficulty, demographics, or error modes. A brief component-level analysis would strengthen the paper.
[1] Gil, Natalia Martinez, et al. "Identifying Homogeneous and Interpretable Groups for Conformal Prediction." UAI. 2024.
[2] Xu, Senrong, et al. "Fair Conformal Classification via Learning Representation-Based Groups." arXiv preprint arXiv:2605.12195 (2026).
Questions
My main questions are to address my concerns listed in the weaknesses section. I am giving a more conservative score, but will consider increasing the score based on responses to these questions and concerns below:
- For the rebuttal, evaluate out-of-domain generalization for at least one dataset and analyze how the SGCP latent component transfers in comparison with the baselines.
- It would be great if the authors can explain in detail the novelty points of their method, in context of what is different from the prior works?
- I am curious how authors view the potential interpretability tradeoff. Perhaps the latent components do have interpretable aspects to them?
- I would also appreciate a more in-depth limitations section. Every method has out-of-scope applications that would lead to failure modes, it is important for future researchers to understand the pros and cons of your method. Also, I understand that it may be difficult due to spacing, but I would recommend including a summarized limitations section in the main manuscript in addition to expanding the limitations section in the appendix.
Limitations
Limitations section is in the appendix instead of the main manuscript and is too surface-level. The authors should try to address potential failure modes of the method to give researchers a better understanding of when their method is appropriate.
Final justification
The authors have addressed most of my main concerns. Thus, I will raise my score to a 4.
Formatting concerns
No violations of formatting
3 comments
Rebuttal
Thank you for the careful assessment. We are grateful for these questions, which prompted us to examine our method more closely. We address each weakness and question below.
W1+Q1. Out-of-domain generalization
A1. During the rebuttal period, we could not turn MIMIC-IV into a multi-institutional benchmark, so we conducted the strongest shift experiment supported by the data. We constructed a patient-disjoint temporal transfer benchmark for MIMIC-IV ICU-delay prediction. The source cohort contains patients whose possible admission year ends by 2016 (), whereas the target cohort contains patients whose possible admission year begins in 2020 or later (). We trained the backbone, router, and component laws on the source cohort and then froze them.
For every method, 7,289 target patients were used only for conformal recalibration and 14,579 were used for testing. We retained , used five prespecified seeds, and excluded race, gender, and insurance from the inputs. We also evaluated an SGCP variant that reestimated only the component laws on an additional disjoint target split. Thus, the learned calibration structure transfers across time, while the final cutoff is recalibrated on the target cohort in the standard manner. At , the results are:
| Method and transfer setting | Coverage | AvgSize | Intersection CovGap | Worst intersection coverage |
|---|---|---|---|---|
| Marginal CP, target recalibration | 89.91±0.48 | 1.183±0.011 | 1.87±0.20 | 85.13±0.53 |
| Exhaustive Equalized, target recalibration | 89.94±0.37 | 1.400±0.008 | 1.00±0.51 | 88.33±1.18 |
| FaReG, target recalibration | 90.72±0.70 | 1.312±0.019 | 1.88±0.08 | 86.86±1.67 |
| SGCP w/ source components, target recalibration | 90.13±0.22 | 1.296±0.024 | 1.72±0.27 | 88.58±0.68 |
| SGCP w/ target component refit, target recalibration | 90.00±0.52 | 1.251±0.018 | 1.58±0.27 | 88.71±0.60 |
Results. These results give a direct, although preliminary, answer to the transfer question. With the source learned structure frozen, SGCP remains at nominal coverage, lowers CovGap relative to Marginal CP, and raises worst intersection coverage from 85.13% to 88.58%. Exhaustive Equalized achieves the smallest CovGap but uses the largest sets. Target refitting yields only a modest further change, suggesting that the source learned score law remains useful after temporal shift.
We regard this as a preliminary finding and a promising direction for further refinement of SGCP. We hope this setup addresses your concern. A rigorous interpretation would require a more systematic investigation, which lies beyond the scope of the present paper. Should time permit, we would be glad to pursue this question further. We appreciatefor encouraging us to examine this question.
W2+Q2. Relation to prior work
A2. We sincerely thank you for raising this concern. Our answer is: Learned-group methods determine which observations should be calibrated together. SGCP learns how each observation's score should be expressed on a shared percentile scale.
Our intent is not to claim novelty for soft grouping itself. Martinez Gil et al. use a learned partition to determine where raw score calibration is performed, while FaReG (Xu et al.) uses learned group membership to construct and combine group specific prediction sets. In both cases, the learned structure defines the groups on which calibration or set correction operates.
SGCP instead uses its latent components to estimate a sample dependent score distribution, , which maps each candidate label score to a local percentile. All transformed scores then share one held out split conformal cutoff.
This distinction matters because a global raw score threshold may not reflect heterogeneous score behavior, while group specific calibration may fragment the calibration data or combine conservative sets, especially for sparse and intersectional groups. SGCP adapts the score before calibration: samples with similar calibration behavior share information through the components, while conformal calibration remains pooled. SGCP therefore aims to reduce the mismatch introduced by global calibration without the data fragmentation of subgroup specific calibration.
This also explains its empirical behavior. Subgroup reliability improves because heterogeneous scores are placed on a more comparable percentile scale, rather than because prediction sets are systematically enlarged. SGCP does not use the evaluated sensitive attributes to define calibration groups, yet the same fitted score law improves reliability across multiple attributes and their intersections while maintaining near nominal marginal coverage and efficient sets.
The distinction is therefore not merely hard versus soft grouping. SGCP uses stochastic grouping to estimate a shared component local score law for multiclass candidate scores, enabling local adaptation before one pooled conformal calibration step. Proposition 3 then relates the coverage error of any fixed measurable subgroup to the remaining transformed score mismatch.
We hope this clarification addresses your originality concern, which may arise from reading SGCP as another discover then calibrate procedure.
W3+Q3. Perhaps the latent components are interpretable?
A3. This is an excellent question, and one that we have also considered carefully.
We believe the answer is yes, although the interpretation is primarily operational rather than immediately clinical. Each component represents a recurring nonconformity score distribution, and its contribution to an individual prediction can be inspected directly.
Every prediction admits the decomposition . For any patient and candidate label, an auditor can inspect the original score , the weights , the component percentiles , each contribution , and the final cutoff comparison. In this way, one can see which learned score regimes made the prediction set larger or smaller.
Following your suggestion, we conducted a post hoc component audit using the five runs from the MIMIC-IV temporal transfer experiment in A1. Because component labels can be permuted across runs, we first aligned them by Hungarian matching on a fixed diagnostic cohort of 2,000 patients. The three aligned target components show progressively more difficult calibration behavior: their responsibility weighted mean scores are 0.058, 0.158, and 0.394; their top 1 error rates are 2.35%, 6.82%, and 25.86%; and their average set sizes are 1.033, 1.162, and 1.582. Their masses also shift from 33.71%, 33.25%, and 33.05% in the source cohort to 15.19%, 27.70%, and 57.11% in the target cohort, revealing a substantial movement toward the more difficult score regime.
We also examined whether these regimes have observable clinical associations. The proportion of patients with public insurance rises from 33.70% to 52.41% and 65.90% across the three components. We view this as useful information for auditing cohort composition, rather than evidence that the components are defined by insurance status or have a causal clinical interpretation.
Finally, we checked that this structure was not simply an artifact of component collapse or random initialization. All three components remain active, with an effective component count of 2.995 out of 3 in the source cohort and 2.613 out of 3 in the target cohort. Across ten seed pairs, the median matched soft agreement is 0.884, and the median hard assignment ARI is 0.751, ranging from 0.594 to 0.830. These results suggest that the components capture a reasonably reproducible calibration structure across runs.
All told, we view the components as statistically interpretable and auditable at the patient level, while their clinical and causal meanings remain unproven . We will make this boundary explicit in the revised paper.
Q4. More in-depth limitations
A4. Thank you for emphasizing this. We will add a concise summary to the main manuscript and substantially expand the appendix.
We will clarify that the conformal guarantee relies on exchangeability between the calibration and test data. Under temporal, institutional, or other distribution shifts, target recalibration is needed to establish coverage for the new cohort. Importantly, because SGCP separates score law learning from conformal calibration, this adaptation does not necessarily require retraining the entire model. As demonstrated in our temporal transfer experiment, the source learned backbone, router, and component laws can remain frozen, while only the final conformal cutoff is recalibrated on target data.
We will also clarify that the subgroup result is mismatch dependent rather than exact distribution free conditional coverage; evaluation on recorded sensitive attributes cannot rule out failures on unobserved or extremely sparse groups; and the latent components represent recurring calibration regimes rather than true patient populations. SGCP also inherits limitations of the predictive backbone and nonconformity score, and the current framework focuses on multiclass classification.
In light of the clearer statement of novelty, the temporal transfer experiment, and the component audit, we would be most grateful if you would reconsider your assessment of the work’s originality and significance. That would be fantastic! We also look forward to any further discussion and would be very happy to address additional concerns. Thank you again!!!
Thanks to the authors for the detailed rebuttal. My main concerns regarding the novelty aspects have been addressed. Thus, I will raise my score to 4.
In terms of domain generalization, I would highly suggest the authors to continue their investigation and include a real cross-dataset transfer result in the final paper. The current MIMIC-IV temporal shift is still quite limited, and cross-system datasets would be needed to test the effect of real domain shifts. As someone working with multi-institution data, my first concern upon reading this paper was the generalizability of the method.
The interpretability angle was something more of a personal curiosity. It would not be surprising if the latent components are difficult to associate with clinical variables. Although it would be interesting if the public insurance association yields some causal explanation.
We are really happy that our clarification has addressed your concerns!
Thank you very much for your thoughtful follow-up and for raising your score. We really appreciate your encouragement!
We completely agree that cross-dataset evaluation is the right direction for further validating the method. The current temporal shift experiments on MIMIC-IV are only a first step, and evaluating cross-institution or cross-system datasets would provide a much stronger test of robustness under real-world domain shifts. This is something we are actively working toward and plan to continue exploring in future work.
We also appreciate your thoughts on interpretability. We share your view that directly linking the latent components to clinical variables may not always be straightforward. At the same time, observations such as the association with public insurance are certainly intriguing, and we think they are worth investigating further from both the clinical and methodological perspectives.
If you have any further suggestions, we would greatly appreciate it if you could update your original review so that we can address them as well. Thanks again for your thoughtful feedback and encouragement. It really means a lot to us :)
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Rebuttal
Thank you very much for the careful review. We appreciate the opportunity to clarify these points below.
W1&Q1. Finite sample coverage within subgroups
A1. We especially appreciate your recognition of SGCP's practical value. Your main theoretical concern is whether SGCP goes beyond marginal validity. It does, and we answer this directly below.
In fact, the submitted paper already provides a finite sample subgroup guarantee, although we agree that Proposition 2 received more attention in the presentation, which made the subgroup result too easy to miss.
Proposition 3 in the main paper, with its proof in Appendix A.3, applies to any fixed measurable subgroup G. Let V=F(s(X,Y)∣X) and define $\Delta_G := \sup_{t\in[0,1]} \left| \Pr(V\leq t\mid X\in G) -\Pr(V\leq t) \right|$.
Thus, ΔG measures the mismatch between the subgroup and population distributions of the transformed score. Write CovG for coverage conditional on Xn+1∈G. Let m=∣Dcal∣ and $k=\lceil (m+1)(1-\alpha)\rceil $. Under calibration-test exchangeability conditional on Dtra and continuity of the marginal law V, Proposition 3 gives $|\mathrm{Cov}_ G-\frac{k}{m+1} | \leq \Delta_G $, and hence subgroup coverage is at least 1−α−ΔG.
Remark 3 connects this bound directly to the oracle local score law Fx⋆. Under the conditional-score continuity condition of Proposition 1 (for brevity, we omit the conditioning on Dcal in the notation),
$\sup_{x,t} \left|\widehat F(t\mid x)-F_x^\star(t)\right| \leq\varepsilon \quad\Longrightarrow\quad \Delta_G\leq2\varepsilon$.
Consequently,
$\left| \mathrm{Cov}_G -(1-\alpha) \right| \leq2\varepsilon+\frac{1}{m+1}$.
Because this statement holds for any fixed measurable G, it also applies to component-induced audit regions whose routing rule is fixed before calibration. The key point is direct: as SGCP better approximates the oracle local score law, its finite-sample subgroup bound tightens, while the independent conformal step preserves marginal validity.
We would also like to be precise about what the theorem does not claim. It is not exact distribution free conditional coverage, and the bound may be loose when the learned local score law is inaccurate and ΔG is large. This is a substantive limitation, and we do not wish to obscure it. Even so, the proposition provides theoretical support for subgroup reliability beyond the usual marginal CP guarantee.
To recap. For subgroup-aware methods, the guarantee is usually established for a prespecified group G: once G is known, the method can provide a direct coverage guarantee for that group, rather than merely an upper bound on its coverage error. Perhaps this is the setting you had in mind. SGCP operates under a considerably more demanding information regime. At no point during learning or calibration is it given any knowledge of the subgroup whose reliability it is ultimately expected to improve. Establishing an exact subgroup-level guarantee under such conditions is therefore far from straightforward. We are grateful that you anticipated this difficulty. Given the information available to SGCP, Proposition 3 represents the strongest guarantee that we can presently establish. We believe, however, that the empirical evidence offers an important complementary perspective. Across nearly all of our experiments, SGCP yields clear improvements in subgroup coverage, supporting its practical effectiveness even where a stronger theoretical guarantee remains elusive.
We hope this clarification addresses your principal theoretical concern.
W2&Q2. Clinical interpretation of the latent components
A2. This is an excellent question. We share your concern that a latent component should not be presented as a clinical explanation simply because it has a distinct density. We want to clarify what is and is not observable in SGCP.
First, SGCP does not assign a patient to a single latent group, nor does it apply a hidden group specific threshold. Instead, each patient receives a soft weight vector over recurring nonconformity score distributions. For a patient x and candidate label y, the transformed score is Vy(x)=∑kwk(x)Fk(s(x,y)).
This decomposition is directly inspectable. For every candidate label, a clinician or auditor can examine the original nonconformity score s(x,y), the patient specific weights wk(x), the percentile assigned by each component Fk(s(x,y)), each contribution wk(x)Fk(s(x,y)), and the final comparison with the shared conformal cutoff. An unusually large prediction set arises when more candidate labels are retained after this comparison, and the contribution of each learned score regime to every inclusion decision can therefore be traced.
We agree, however, that this is an operational explanation in score space, rather than an immediate clinical explanation of why a patient is difficult to predict. To investigate whether the learned structure nevertheless has stable and meaningful properties, we conducted a post hoc component audit using the five runs from the MIMIC-IV temporal transfer experiment. After aligning components across runs, the three target regimes exhibit increasing mean true label scores, top 1 error rates, and average prediction set sizes. Their prevalence also changes substantially from the source to the target cohort, revealing a temporal shift toward the more difficult calibration regime.
The learned structure is also reasonably reproducible. All three components remain active, the median matched soft agreement across ten seed pairs is 0.884, and the median hard assignment ARI is 0.751. We additionally observe associations between the components and recorded patient characteristics, such as insurance status. We treat this as a preliminary finding, and rigorous interpretation requires further work.
All told, our view is that SGCP is not opaque at the level of the calibration mechanism. Each label inclusion decision has a patient level audit trail. At the same time, translating these recurring score regimes into clinically meaningful explanations requires dedicated clinical analysis.
Q3. How is K determined, and what happens when it is misspecified?
A3. We want to clarif that K is a resolution parameter, not a claimed number of demographic or clinical populations. If K is misspecified, it may affect how accurately SGCP represents the local score law and may therefore reduce its subgroup reliability or efficiency gains. Importantly, however, such misspecification does not invalidate the finite sample marginal coverage guarantee, because the final cutoff is still estimated on an independent conformal calibration split.
More specifically, a smaller K gives a coarser description of score heterogeneity; with a larger K, the soft mixture can refine or overlap existing regimes rather than forcing patients into a hard partition. We checked K∈{3,6,9,12} directly. As mentioned in Figures A11–A12, a moderate K already captures the main low- and high-score regimes, while extra components mostly refine or overlap them. Figures A13–A14 show stable coverage, AvgSize, and CovGap across all four choices, so the result does not depend on a delicate value of K.
Result. These findings suggest that SGCP is robust to moderate misspecification of K, but they do not identify a unique structural value.
Thank you again for pressing us on these points. The questions helped us see that the marginal guarantee, the relaxed subgroup result, and the empirical subgroup claim were too easy to conflate. We hope the bound and component analysis clarify both what SGCP provides and what it does not. We hope that our answers can ease your concerns. If there are any other concerns, we also very happy to continue our discussion. Thank you!!!