Anchoring LLM-based Chest X-ray Report Generation via Diffusion Language Planning
Jiechao Gao, Chang Liu, Yuandong Pan, Ying Liu, Michael Lepech
NeurIPS 2026
Abstract. While Large Language Models (LLMs) have significantly advanced radiology report generation (RRG) with strong generative priors, standard autoregressive decoders still suffer from sequential error accumulation when they must infer all clinical structures directly from images. Diffusion Language Models (DLMs) have recently emerged as a non-autoregressive paradigm with iterative masking and denoising mechanisms. Instead of replacing the mature language decoder with a DLM, we reveal that the key value of DLMs for RRG lies in controllable clinical planning, where the model predicts globally consistent anchor points before free-text realization. To harness this complementary strength, we propose ANCHOR-GEN, the first framework that uses a DLM as an explicit diffusion language planner for RRG. Rather than forcing the autoregressive decoder to infer every critical structure from visual tokens alone, ANCHOR-GEN predicts a structured clinical canvas that serves as clinically grounded anchor points. An autoregressive LLM then leverages these anchors to complete report generation with both fluency and clinical faithfulness. By systematically combining non-autoregressive planning and autoregressive decoding, our unified pipeline is trained with structured denoising, hierarchical coarse-to-fine supervision, and planner-decoder binding objectives. Extensive experiments on the public \textsc{MIMIC-CXR} benchmark demonstrate that ANCHOR-GEN improves clinical faithfulness over prior works. Comprehensive analyses and ablations further show that diffusion planning and causal decoding offer complementary strengths for RRG, and that integrating them in one pipeline provides an effective route toward more faithful medical text generation.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:49 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
ANCHOR-GEN separates structured clinical planning from free-text realization. A Diffusion Language Planner performs masked infill over a structured clinical canvas of anchor fields (disease existence, laterality, location, severity, devices), a Gated Planner-Memory Bridge passes planner outputs to the decoder through both a textual anchor phrase channel and a planner-hidden-state visual channel, and an Anchored Causal Decoder verbalizes the anchors into a fluent report. Training uses a staged objective with structured denoising and hierarchical coarse-to-fine supervision. Experiments on MIMIC-CXR (with IU X-Ray in the appendix) report gains on NLG and CheXbert-based clinical efficacy metrics with paired-bootstrap significance testing.
The major concerns are summarized as follows:
-
Necessity of diffusion planning. The anchor-then-generate paradigm is already used by S2D-Align/EKAGen/PromptMRG, and against S2D-Align the gap sits at the third decimal (F1 0.612 vs 0.608), so whether diffusion is necessary is unclear (Reviewer 8ozo); Reviewer bP32 asks for comparison to a single-step multi-label classifier or an iteratively refined LLM predictor.
-
Faithfulness evidence. CheXbert F1 does not capture faithfulness beyond label presence — please add RadGraph/RadCliq/RateScore or an entity/relation- level hallucination rate (Reviewer 8ozo); Reviewer bP32 notes the case study lacks systematic failure categories.
-
Method clarity. Reviewer g8e3 finds Eq. 4-9 confusing (Q_plan, H_m priors, tau schedules, canonical-phrase rendering, mask removal) and asks which CE F1 variant is reported and whether code will be released.
-
Ontology generality. All experiments are on chest X-ray so generality is untested (Reviewer 8ozo); Reviewer g8e3 asks how rare/additional pathologies would be handled.
Final justification
During the rebuttal phase, the reviewers and authors engaged in sufficient discussion. Two reviewers felt that their concerns had been fully addressed and raised their scores accordingly. Although one reviewer did not provide a final recommendation, I think the authors provided an adequate response.
Read meta-review
Meta-review
ANCHOR-GEN separates structured clinical planning from free-text realization. A Diffusion Language Planner performs masked infill over a structured clinical canvas of anchor fields (disease existence, laterality, location, severity, devices), a Gated Planner-Memory Bridge passes planner outputs to the decoder through both a textual anchor phrase channel and a planner-hidden-state visual channel, and an Anchored Causal Decoder verbalizes the anchors into a fluent report. Training uses a staged objective with structured denoising and hierarchical coarse-to-fine supervision. Experiments on MIMIC-CXR (with IU X-Ray in the appendix) report gains on NLG and CheXbert-based clinical efficacy metrics with paired-bootstrap significance testing.
The major concerns are summarized as follows:
-
Necessity of diffusion planning. The anchor-then-generate paradigm is already used by S2D-Align/EKAGen/PromptMRG, and against S2D-Align the gap sits at the third decimal (F1 0.612 vs 0.608), so whether diffusion is necessary is unclear (Reviewer 8ozo); Reviewer bP32 asks for comparison to a single-step multi-label classifier or an iteratively refined LLM predictor.
-
Faithfulness evidence. CheXbert F1 does not capture faithfulness beyond label presence — please add RadGraph/RadCliq/RateScore or an entity/relation- level hallucination rate (Reviewer 8ozo); Reviewer bP32 notes the case study lacks systematic failure categories.
-
Method clarity. Reviewer g8e3 finds Eq. 4-9 confusing (Q_plan, H_m priors, tau schedules, canonical-phrase rendering, mask removal) and asks which CE F1 variant is reported and whether code will be released.
-
Ontology generality. All experiments are on chest X-ray so generality is untested (Reviewer 8ozo); Reviewer g8e3 asks how rare/additional pathologies would be handled.
Final justification
During the rebuttal phase, the reviewers and authors engaged in sufficient discussion. Two reviewers felt that their concerns had been fully addressed and raised their scores accordingly. Although one reviewer did not provide a final recommendation, I think the authors provided an adequate response.
1 comment
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 4/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper proposes ANCHOR-GEN, a framework that uses a Diffusion Language Model (DLM) as an explicit clinical planner for chest X-ray radiology report generation (RRG), separating non-autoregressive anchor prediction from autoregressive report realization. It has three components: (1) a Diffusion Language Planner (DLP) that performs masked infill over a structured clinical canvas to predict grounded anchor fields such as disease existence, laterality, location, severity, and devices in a coarse-to-fine manner; (2) a Gated Planner-Memory Bridge (GPMB) that connects the planner and decoder through a dual channel, injecting anchor phrases as a textual prompt and planner hidden states as planner-aware visual evidence; and (3) an Anchored Causal Decoder (ACD), an autoregressive LLM that verbalizes the anchored signals into a coherent free-text report. The model is trained with a staged objective combining structured denoising, hierarchical coarse-to-fine supervision, and planner-decoder binding. Experiments on MIMIC-CXR, with supplementary results on IU X-Ray, report gains on NLG and CheXbert-based clinical-efficacy metrics, paired-bootstrap significance testing, and ablations over planner type, GPMB channels, and training objectives.
Strengths and weaknesses
Strengths
-
Clear and coherent methodological motivation. The separation of non-autoregressive structured planning from autoregressive realization is clean and well argued. The paper clearly explains the complementary roles of DLP, GPMB, and ACD, and the overall narrative is easy to follow from Figure 1.
-
A legitimate and clearly articulated combination of existing ideas. Under the General originality criteria, originality does not require every component to be new. Combining diffusion-based structured planning, a dual-channel planner-decoder bridge, and autoregressive report realization is a recognizable methodological contribution. The paper also provides a reasonable explanation of why these components may be complementary.
-
Reasonably complete experiments with significance testing. The comparison covers a broad set of baselines, and the headline gains are reported as statistically significant under paired-bootstrap resampling. The planner-type, bridge-channel, and training-objective ablations address several important design choices.
-
Informative ablations. The result that using the DLM directly as the decoder reaches only 0.343 F1 supports the decision to retain autoregressive realization. The observation that the Transformer-, LLM-, and BERT-based planners provide only small or negative gains, while the DLM planner produces a clearer improvement, is useful evidence for the structured diffusion-planning design.
-
Honest discussion of limitations. The conclusion acknowledges the dependence on a predefined clinical ontology and structured labels derived from reports, as well as the resulting limited coverage of rare, ambiguous, or nuanced findings
Weaknesses
-
The improvement over the strongest baseline is statistically significant but small. Against S2D-Align, the reported gains are at the third decimal: F1 improves from 0.608 to 0.612, precision from 0.613 to 0.616, recall from 0.606 to 0.609, BLEU-1 from 0.422 to 0.427, and ROUGE-L from 0.332 to 0.335. The paired-bootstrap result establishes statistical significance, but the paper does not report effect sizes or confidence intervals that would help assess the magnitude and practical meaning of these gains. In addition, the much larger improvement from the internal BASE model, 0.465 to 0.612 F1, should not be interpreted as the improvement over the strongest existing method.
-
The diffusion-specific originality is not fully isolated. I no longer regard the use of an established “predict anchors, then generate a report” paradigm as inherently insufficient: the DLP-GPMB-ACD combination is a legitimate form of originality under the General criteria. My remaining concern is that the experiments do not fully isolate whether the improvement comes specifically from diffusion-based planning rather than from additional structured supervision, staged objectives, or modeling capacity. The planner-type ablation is helpful, but a matched-capacity simpler structured predictor that emits the same 35 fields would provide a more decisive comparison.
-
The evidence for the significance and scope of the empirical gains is limited. The experiments support the chest X-ray RRG setting, but the main clinical-faithfulness conclusion is evaluated primarily through CheXbert label-presence metrics. The main results do not include RRG-specific metrics such as RadGraph, RadCliQ, or RateScore. Thus, it remains unclear whether the small improvement in CheXbert F1 corresponds to a meaningful improvement in entity/relation correctness or report-level factual quality. I do not require clinical deployment or domain-expert evaluation under the General criteria, but the claims should be scoped to the evidence actually provided.
-
The central faithfulness claim remains under-measured. The paper centers its contribution on improving clinical faithfulness, but planner-level factual accuracy, anchor usage, and hallucination analysis are placed in the appendix, while entity- and relation-level hallucination measures are not prominent in the main evaluation. Because faithfulness is a central methodological claim rather than merely application-side motivation, more direct evidence belongs in the main results.
-
Complexity and reproducibility remain concerns. The pipeline includes 35 structured fields, hierarchical coarse-to-fine supervision, two planner-decoder bridging channels, staged training objectives, and several thresholds. The manuscript reports implementation details and single-A40 execution, but reproducing the planner-data preprocessing—including deterministic consistency rules, the location-token set, and the canonical anchor bank—may be difficult without code or a more complete specification.
Reassessed under the General contribution criteria, this paper presents a technically coherent and clearly motivated combination of diffusion-based structured planning and autoregressive report realization. I regard this combination as a legitimate form of originality, and the planner-type, bridge-channel, and training-objective ablations provide useful supporting evidence. My main reservations are not the absence of deployment, domain-expert engagement, or cross-modality validation. Rather, they concern whether the central clinical-faithfulness claim is adequately supported and whether diffusion planning provides a meaningful advantage over a matched simpler structured predictor. The gain over the strongest baseline is small, while more direct entity/relation-level faithfulness and hallucination evidence is limited or relegated to the appendix. On balance, the reasons to reject slightly outweigh the reasons to accept, although stronger faithfulness evidence or a decisive matched-planner comparison could raise my assessment.
Questions
-
Evidence for the central faithfulness claim. Could the authors report RadGraph, RadCliQ, RateScore, and an explicit entity/relation-level hallucination rate in the main results? Clear improvements on these measures would show whether the DLM planner provides faithfulness gains that CheXbert F1 does not capture and would raise my significance assessment.
-
Magnitude of the gain over the strongest baseline. Beyond the paired-bootstrap p-value, could the authors report effect sizes or confidence intervals and discuss whether an F1 improvement from 0.608 to 0.612 is clinically or scientifically meaningful?
-
A matched simpler alternative. If the DLM planner were replaced with a lighter, matched-capacity structured predictor that emits the same 35 fields and receives the same structured supervision, how much would end-to-end performance change? This comparison would more directly quantify the incremental value of diffusion-based planning.
-
Scope of the claims. The current evidence mainly establishes performance for chest X-ray report generation. Is the intended contribution specifically scoped to CXR RRG? If broader medical report generation is claimed, what evidence supports transferring the fixed 35-field ontology, location tokens, and canonical anchor bank beyond this setting?
-
Contribution of the two GPMB channels. In the bridge ablation, the visual-only channel reaches 0.592 F1, which is already close to the dual-channel result of 0.612. Could the authors further characterize the marginal contribution of the textual-anchor channel on top of the visual channel and provide representative success and failure cases?
Limitations
The authors candidly discuss the dependence on a predefined clinical ontology and structured labels derived from reports, together with the resulting limited coverage of rare, ambiguous, or nuanced findings. This is appreciated. Under the General criteria, I do not additionally require evidence of clinical deployment or domain-expert engagement. My remaining limitations-related concerns are the small magnitude of improvement over the strongest baseline, reliance on CheXbert for the primary clinical evaluation, and the reproducibility burden of the structured preprocessing pipeline. These issues are already reflected in the assessment above and should not be double-counted.
Final justification
I have read the rebuttal and both follow-up clarifications. The authors resolved the numerical and comparator inconsistencies in the additional analysis and provided a corrected comparison against S2D-Align using 1,000 study-level paired-bootstrap resamples.
The corrected results confirm that the gains on conventional NLG and CheXbert metrics are small but statistically significant—for example, BLEU-1 improves by 0.005 with a 95% CI of [0.001, 0.009], and CE F1 improves by 0.004 with a 95% CI of [0.002, 0.006]. More importantly, the faithfulness-oriented results show substantially larger and consistently supported improvements: RadGraph F1 increases by 0.080 [0.064, 0.097], RadCliQ decreases by 1.450 [-1.630, -1.270], RaTEScore increases by 0.120 [0.098, 0.141], and Report Halluc. decreases by 0.130 [-0.155, -0.105], corresponding to a reduction from 0.18 to 0.05. None of these confidence intervals crosses zero.
These results directly address the main score-changing condition in my review: whether the added complexity produces a clear clinical-faithfulness improvement beyond CheXbert. The planner ablation also provides useful, although not fully conclusive, evidence that the DLM planner contributes beyond the Transformer-, LLM-, and BERT-based alternatives. Under the General contribution criteria, I credit the combination of structured diffusion planning, gated planner-decoder bridging, and autoregressive realization as a legitimate form of originality.
Some concerns remain. The improvements on conventional metrics are marginal; the experiments do not completely separate the diffusion mechanism from structured supervision and staged training; the demonstrated scope remains chest X-ray report generation; and full reproducibility still depends partly on the promised release of code, annotations, and model weights. These are meaningful limitations, but after the corrected faithfulness analysis they no longer make the overall balance negative.
I therefore update my overall rating from 3 (Borderline Reject) to 4 (Borderline Accept) and my Significance score from 3 to 4.
Formatting concerns
None observed.
7 comments
Rebuttal
Dear Reviewer 8ozo,
We sincerely thank you for the careful review and constructive suggestions, which help us improve the empirical analysis, positioning, and reproducibility of this paper. In the following, we provide detailed responses to your concerns.
Q1: The improvements over S2D-Align are small in absolute magnitude; please report effect sizes and confidence intervals and discuss whether the gains are practically meaningful.
A1: We agree with this assessment and would like to further clarify this comparison.
Relative to S2D-Align, Anchor-Gen improves both NLG and CE metrics by a small margin.
Yet, we would like to point out that higher NLG and CE scores do not always correlate to reports in better quality, as the former mainly measures lexical overlap (-gram based), so that models can obtain high scores by overfitting descriptive template texts; while the latter does not always accurately reflect report faithfulness via the CheXbert labeler.
Our observations align well existing published studies [1, 2, 3].
To further support this observation, we conduct further comparisons with S2D-Align with respect to RadGraph F1, RadCliQ, RaTEScore, and Report Halluc., as is suggested in Q3, with results shown below.
| Method | RadGraph F1 ↑ | RadCliQ ↓ | RaTEScore ↑ | Report Halluc. ↓ |
|---|---|---|---|---|
| S2D-Align | ||||
| Anchor-Gen | 0.29 | 1.13 | 0.57 | 0.05 |
Compared with S2D-Align, Anchor-Gen improves RadGraph F1 by 38.1%, where RadGraph F1 serves as a more fine-grained evaluator than that of the CE metric, further confirming that the promising NLG performance originates from accurate diagnoses rather than overfitting the patternized texts.
For comparison on RadCliQ, our method reduces by 56.2%, a large improvement magnitude demonstrating stronger overall clinical consistency between the generated and ground-truth reports.
Regarding the RaTEScore, which mainly measures the preservation of report-level clinical semantics, Anchor-Gen outperforms S2D-Align by 26.7%.
Finally, it reduces Report Halluc. by 72.2%, showing that the generated reports contain substantially fewer unsupported clinical findings, where this observation aligns well with our advantage on RadGraph F1 and RadCliQ.
Collectively, these improvements demonstrate that the benefit of Anchor-Gen is more evident in clinically grounded and faithfulness-oriented evaluation than in conventional lexical-overlap metrics.
Note that all gains in our main paper as well as the additional experiments pass paired bootstrap testing with . We will add all aforementioned results and their corresponding discussions in the final revision of our paper.
References in A1:
- [1] Zhang, Y., Wang, X., Xu, Z., Yu, Q., Yuille, A., & Xu, D. (2020). When Radiology Report Generation Meets Knowledge Graph. AAAI, 34(07), 12910–12917.
- [2] Jain, S., Agrawal, A., Saporta, A., Truong, S. Q. H., Duong, D. N., Bui, T., Chambon, P., Zhang, Y., Lungren, M. P., Ng, A. Y., Langlotz, C. P., & Rajpurkar, P. (2021). RadGraph: Extracting Clinical Entities and Relations from Radiology Reports. In J. Vanschoren and S. Yeung (Eds.), NeurIPS D&B
- [3] Delbrouck, J.-B., Xu, J., Moll, J., Thomas, A., Chen, Z., Ostmeier, S., Azhar, A., Li, K. Z., Johnston, A., Bluethgen, C., Reis, E. P., Muneer, M. S., Varma, M., & Langlotz, C. (2025). Automated Structured Radiology Report Generation. ACL, 26813–26829.
Q2: The anchoring paradigm is already used by prior RRG methods, so the paper should isolate the incremental value of diffusion planning relative to a simpler anchor predictor.
A2: We agree that the suggested two-stage RRG paradigm, which first predicts plans and then verbalizes them into final repors, is not newly proposed.
To clarify the positioning of our method, we would to distinguish the main difference between these studies and Anchor-Gen via further illustrations.
Specifically, we notice that most existing methods are proposed before 2023, in the time when LLM-based RRG methods are not developed, meaning that these methods manage to handle the RRG task based on from-scratch training with dedicated small encoder-decoder models.
Another notable aspects of these studies lies at their paradigm to model plan prediction via vanilla Transformer- or BERT-based architecutre, where our main difference herein is to use non-autoregressive paradigm to retain the hierarchical structures of clinically-grounded planning.
To enhance the aforementioned illustrations for a better positioning of Anchor-Gen, we will particularly add these discussions to the second paradigm of Sec. 2 in our revised paper.
Moreover, to showcase the advantage of non-autoregressive paradigm against autoregressive ones, we report this comparison in Tab. 1 of our main paper, as is also shown below.
Here, we highlight the best-performing and second-best results in boldface and with underlines, respectively.
| Planner | B@1 ↑ | B@2 ↑ | B@3 ↑ | B@4 ↑ | MTR ↑ | R-L ↑ | CE P ↑ | CE R ↑ | CE F1 ↑ |
|---|---|---|---|---|---|---|---|---|---|
| +Trans. Planner | 0.260 | 0.179 | |||||||
| +LLM Planner | 0.388 | 0.254 | 0.177 | 0.126 | 0.170 | 0.281 | 0.460 | 0.477 | 0.468 |
| +BERT Planner | 0.392 | 0.123 | 0.169 | 0.284 | 0.423 | 0.414 | 0.418 | ||
| +DLM Planner (Ours) | 0.427 | 0.266 | 0.186 | 0.151 | 0.177 | 0.335 | 0.616 | 0.609 | 0.612 |
Q3: The clinical-faithfulness evaluation is too narrow because it relies mainly on CheXbert. Please add RadGraph, RadCliQ, RaTEScore, and an explicit hallucination analysis.
A3: We agree that the NLG and CheXbert-based CE metrics might be biased, and report the results with respect to RadGraph F1, RadCliQ, RaTEScore, and Report Halluc. (following LLM-RG4) below:
| Method | RadGraph F1 ↑ | RadCliQ ↓ | RaTEScore ↑ | Report Halluc. ↓ |
|---|---|---|---|---|
| R2Gen | 0.17 | 2.79 | 0.48 | 0.78 |
| R2GenCMN | 0.20 | 2.87 | 0.70 | |
| R2GenGPT | 0.12 | 2.86 | 0.43 | 0.92 |
| LLM-RG4 | 0.15 | 2.82 | 0.43 | 0.02 |
| S2D-Align | 0.45 | |||
| Anchor-Gen | 0.29 | 1.13 | 0.57 | 0.02 |
Here, we have already discussed the comparison between Anchor-Gen and S2D-Align in A1, and further analyze the performance advantage against other methods:
R2GenandR2GenCMNare two representative encoder-decoder RRG methods, where we notice that these methods still perform heuristicly andAnchor-Genobtains an average performance gain by 58.2%.R2GenGPTis one of the first LLM-based RRG methods, yet we observe that direct adaptation of LLMs for RRG does not always lead to better clinical accuracies, where this observation aligns well with the performance drop of all metrics in the comparison table.LLM-RG4further enhances RRG with various context input settings. While comparable hallucination rate is shown, its performance on more fine-grained clinical metrics are not as competitive.
Q4: The many interacting modules, losses, fields, stages, and thresholds make the system difficult to reproduce; the preprocessing rules, runtime overhead, and code availability should be clarified.
A4: We would like to clarify that we have included several details in Sec. 3 and Appendix A, but they might not be sufficiently salient for readers to notice. In our final revision, we will further enhance the illustration of Sec. 4. For your concerns of the code availability, we will release the code, annotations, and the corresponding model weights upon paper acceptance.
Q5: The experiments cover only chest X-ray datasets. How would the approach transfer to CT or other modalities, and what is the cost of adapting the 35-field ontology and canonical anchor bank?
A5: We agree with you that the data issue is one of the limitations by the time we proceed this work, as the available datasets are mostly chest X-ray. In our subsequent research, we have successfully extend this paradigm to paranomic radiology datasets, where results show similar effectiveness for RRG in other modalities. For the ontology and canonical anchor bank under such a setting, we notice that the terminologies differ a lot in other modalities, and thus, some hyper-parameter details, e.g., the vocabulary size, the number of anchor fields, might be slightly different, but we still keep the same paradigm proposed in this paper. We hope this additional information could address your concerns.
Q6: In the GPMB ablation, the visual-only channel is already close to the dual-channel model. What is the marginal contribution of textual anchors on top of planner-aware visual states, and when does this channel help or fail?
A6: We would like to further clarify this.
Essentially, the two channels serve different roles.
Specifically, the planner-aware visual states preserve continuous confidence and field interactions through the residual bridge, while the textual channel explicitly enumerates which clinical concepts should be verbalized.
The textual channel is most useful when a correct low-frequency anchor might otherwise be ignored by the decoder.
It can fail when a false-positive anchor is retained, which is why the baseline with prompt injection, i.e., Prompt-Only in Tab. 3 (a), obtains lower scores.
We hope that our responses address your concerns. Please feel free to let us know if any questions remain, and we would be happy to provide further clarification.
Best,
Authors from Submission 10723
Follow-up Comments to Authors
Thank you for the detailed rebuttal. The additional RadGraph, RadCliQ, RaTEScore, and report-hallucination results materially address my main concern about whether the method improves clinical faithfulness beyond CheXbert, and they may affect my final assessment. Before I update it, could you please clarify the following points?
- In A1, the Report Halluc. value for ANCHOR-GEN is 0.05, corresponding to a 72.2% reduction relative to S2D-Align at 0.18. In A3, the corresponding ANCHOR-GEN value is 0.02. Which value is correct, and what is the correct relative reduction?
- Please confirm that the four additional metrics for ANCHOR-GEN and S2D-Align were computed on the same MIMIC-CXR test split, using the same generated reports/checkpoints as the main-table evaluation and the same standard implementations and preprocessing for both methods.
- Since the rebuttal states that all additional gains pass paired-bootstrap testing at , could you report the corresponding paired 95% bootstrap confidence intervals for the ANCHOR-GEN minus S2D-Align differences, together with the number of bootstrap resamples?
No additional experiments or datasets are being requested here; I only need clarification of the consistency and evaluation protocol of the newly reported evidence.
Response to Follow-up Comments by Reviewer 8ozo
Dear Reviewer 8ozo,
We sincerely thank you for your response, and would like further clarify based on your concerns. Here are some answers below:
-
For your concerns of the values of Report Halluc., we would like to sincerely apologize that the value 0.02 was a typo. The correct version should be 0.05, and correspondingly, the correct reduction relative is 72.2%. We will pay extra attention to this result when adding it to our final revised paper.
-
For your concerns of the implementation setup, we thank you for your careful reminders. We confirm that all four additional metrics are computed on the MIMIC-CXR test split following the standard implementations, checkpoints, officially generated reports, and preprocessing setup of the compared methods.
-
For more details of the paired-bootstrap testing, we use 1,000 study-level paired bootstrap resamples. In each resample, we sample the same set of MIMIC-CXR test studies with replacement for both
Anchor-GenandS2D-Align, recompute all metrics, and record their paired differences as . The specific 95% confidence intervals (CIs) for the performance differences on all computed metrics are summarized in the table below:
| Metric | Mean Difference | 95% Confidence Interval (CI) |
|---|---|---|
| BLEU-1 | +0.028 | [+0.015, +0.041] |
| BLEU-2 | +0.004 | [+0.001, +0.007] |
| BLEU-3 | +0.005 | [+0.002, +0.008] |
| BLEU-4 | +0.024 | [+0.014, +0.034] |
| METEOR | +0.004 | [+0.001, +0.007] |
| ROUGE-L | +0.046 | [+0.032, +0.060] |
| CE Precision | +0.153 | [+0.120, +0.186] |
| CE Recall | +0.129 | [+0.105, +0.153] |
| CE F1 | +0.141 | [+0.118, +0.164] |
| RadGraph F1 | +0.080 | [+0.064, +0.097] |
| RadCliQ | -1.450 | [-1.630, -1.270] |
| RaTEScore | +0.120 | [+0.098, +0.141] |
| Report Halluc. | -0.130 | [-0.155, -0.105] |
Because none of these 95% confidence intervals cross zero, the substantial improvements achieved by our method are statistically significant (). Thank you for pointing this out. We will add these extra details to our final revision.
If you have any further question, please feel free to leave further message. We would be happy to address any of your potential concern.
Best,
Authors from Submission 10723
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper presents Anchor-Gen, a novel approach for X-ray report generation that is based on structured report templates and a diffusion model that iterates over an initial report. Recognizing that end-to-end report generation from the image is fragile because the training process inherently encodes language fluency instead of clinical correctness, Anchor-Gen breaks with the common tradition of simple next-token generation. Instead, a heavily restricted template report is first populated with clinical facts where possible, and then decoded into a full report. The resulting report generator achieves state-of-the-art results on MIMIC-CXR.
Strengths and weaknesses
Strengths:
- An approach that breaks with the previous paradigm by identifying a key weakness and fixing it.
- State-of-the-art performance on the industry standard dataset for this task.
Weaknesses:
- Explanations are in-depth and explicit, although sometimes confusing in terms of nomenclature sometimes (see questions).
- Discussion of limitations feels very limited.
- Case Study section seems to establish trends based on only a single case, which is insufficient.
- Statistical significance unclear.
Questions
Questions:
- Does the report template approach you pursue fundamentally limit the applicability of your method to datasets with an arbitrary amount of pathologies? If not, how would additional and/or rare pathologies be handled? If yes, how would this problem have to be approached for future iterations of this work?
- When referencing the CE metrics, which F1 score is reported? F1-micro across all 14 classes, or a different one? At times, different papers have reported different values here, and this will significantly influence results and comparisons.
- Is the statistical significance claimed in Sec. 5 also given for comparison against, say, S2D-Align or MAIRA-1? What is the “strongest directly comparable” baseline? And what is the actual uncertainty of your results? With that many lexical metrics reported, one could conceivably remove a few less relevant ones (e.g. BLEU-1 to BLEU-3) and use the extra space to give concrete numbers for uncertainties.
- Will project code be made publicly available? Doing so would be a significant strength of the paper.
- Would you consider slightly rewriting the method explanation? The section is structured nicely, but not entirely clear in several places, and may benefit from some clarifications (see below).
Methodology-related questions:
- Eq.4 - What exactly is Q_plan?
- Eq.5 - Is H_m (prior) different from the later H_m? What exactly is the difference? Please elaborate.
- Eq.7 - What exactly is H_plan,m? How does it relate to S̃ from before? If it is not the same, an explicit mathematical step would be helpful here.
- Eq.6+8 - How are the Tau values chosen? Are they fixed or per token m? Is there some heuristic for picking this value? Please elaborate.
- Eq.8 - It looks like all steps so far allow [MASK] tokens to survive with a certain probability. When are they removed? Do you continue denoising until they are gone? If so, does Tau ever change to expedite this process?
- p.5 l.185-186 - “We render the predicted canvas into canonical phrases that summarize positive findings and device states [...]” - How exactly is this done?
- Eq.9 - What is G, what is h_ak? What is the idea behind reusing h_ctx, should information from it not already be encoded in S and therefore R(S)?
- What exactly does the output after DLP look like? Is it human-readable but with limited vocabulary still? Might be helpful for a red thread to follow along.
Limitations
yes
Final justification
I believe that the authors have adequately explained all questions and addressed concerns raised by the reviewers. Consequently, I have updated my scores, and my final recommendation to a 4 (Weak Accept).
Formatting concerns
no
6 comments
Rebuttal
Dear Reviewer g8e3,
We sincerely thank you for the careful review and constructive suggestions, which help us improve the clarity, reproducibility, and experimental presentation of this paper. In the following, we provide detailed responses to your concerns.
Q1: Does the predefined report-template or clinical-canvas design limit the method to a fixed pathology inventory, and how are additional or rare pathologies handled?
A1: For your concerns, we would like to illlustrate as below. Unlike text generation in the general domain, whose vocabulary is relatively more open and diversified, we notice that the vocabulary of radiology reports is relatively fixed, where doctors need to use dedicated descriptive texts in diagnosing different syndromes. Thus, while such a fixed-vocabulary design seems to be a problem in the general domain, it does not affect RRG. For rare findings and pathologies, we annotate our data from 270,790 reports of the MIMIC-CXR training set, which should be sufficient to cover the majority cases. We will add the aforementioned discussions to Sec. 3.
Q2: Which CheXbert F1 score is reported: micro-F1 over all 14 classes, macro-F1, or another definition?
A2: We report micro-based F1 scores in all our experiments, and will clarify this in our revision
Q3: Is the statistical significance claim in Sec. 5 computed against S2D-Align or MAIRA-1, which method is the strongest directly comparable baseline, and what are the uncertainty or confidence intervals?
A3: The baseline refers to S2D-Align. Here, we conduct the paired bootstrap test between Anchor-Gen and S2D-Align with improvements satisfying .
Q4: Will the project code and preprocessing pipeline be publicly released?
A4: Yes, we will release the code, data annotations, and the best-performing model weights as soon as our paper is officially accepted.
Q5: The method section is structurally organized but remains difficult to follow and would benefit from a clearer end-to-end explanation.
A5: Thank you for pointing out this issue. We clarify it in an end-to-end manner as follows:
- Given a radiograph , the visual encoder first extracts image tokens as , after which the cross-modal connector produces the decoder-aligned image states .
- The learnable planner queries interact with through the attention-based context projector, producing the image-conditioned planner context . The context is further summarized as .
DLPoperates on the structured clinical canvas . It initializes a partially masked seed canvas , predicts the categorical distribution of each masked field as , and progressively completes the elements through denoising. This process produces the completed canvas and final planner states .- The completed canvas is rendered into candidate phrases as . Each phrase is assigned a confidence score , and the phrase scorer retains the confident candidates to construct the final anchor set .
GPMBconverts into the textual anchor prompt and injects into the original visual states . Specifically, it computes the residual gate as and produces the planner-aware visual states as .- Finally,
ACDconditions the report decoder on and to generate the report .
To offer a more intuitive presentation of this pipeline, we will add a pseudo algorithm in our final revised paper.
Q6: In Eq. 4, what exactly is ?
A6: is a learnable bank of planner query tokens, shared across studies and repeated along the batch dimension. The context projector uses these queries to cross-attend to the image states and produces image-conditioned planner tokens following Eq. (4). We will clarify its definition and shape after Eq. (4).
Q7: In Eq. 5, how does the prior head differ from the later field head, and are the two instances of the same module?
A7: They are different modules with different inputs and roles. We will revise the notation to make this explicit:
- is a coarse-field prior head applied to the pooled study-level context before iterative denoising. It is used only for fields in .
- is a field-specific denoising head applied to the token-level planner state at iteration .
The prior head determines whether a confident coarse seed should initialize a field, whereas the denoising head predicts or refines the field in the context of the partially completed canvas. Note that the two heads do not share parameters.
Q8: In Eq. 7, what exactly is , and how is it computed from the partially masked canvas ?
A8: is the contextual hidden state of field after DLP jointly encodes the complete partially masked canvas and the image-conditioned context. Formally, it is computed by:
Here, is the -th row of this matrix. The field head then maps this state to the categorical distribution:
This equation makes the dependency on explicit.
Q9: In Eqs. 6 and 8, how are and chosen, and are the thresholds fixed globally, stage-specific, or field-specific?
A9: They are fixed globally. Specifically, these thresholds are selected based on the best-performing setting on the validation split and remain fixed during inference.
Q10: Eq. 8 appears to allow mask tokens to survive. When are all remaining masks removed, and does the threshold schedule change to complete denoising?
A10: We would like to clarify that the thresholded update is used during the intermediate stages to avoid committing uncertain fields too early. The final canvas cannot contain [MASK] values because the rendering function accepts only valid field values. We do not change the schedule during complete denoising.
Q11: How is the predicted clinical canvas deterministically rendered into canonical phrases?
A11: Rendering is a combination of rule- and LLM-based verbalization procedure. For every finding whose status is Present, the renderer collects its non-empty severity, laterality, and region fields in a fixed order and maps the normalized tuple to a canonical phrase. Device fields are rendered when their state is present. Findings labeled Absent, unresolved contradictions, and duplicate mentions are not emitted as positive anchors.
We will add some specific examples in our final revision to make the aforementioned processes more intuitive.
Q12: In Eq. 9, what are and , and why is reused if image information is already encoded in the canvas?
A12: is the pooled DLP hidden state of the fields that participate in candidate phrase . is a trainable phrase-scoring MLP, and converts its output into retention probability .
Reusing is intentional. The discrete canvas retains categorical clinical decisions but discards continuous image condition. Thus, conditioning the scorer on allows the model to focus on the original image input. We will distinction more explicit after Eq. (9) in our final revision.
Q13: What does the DLP output look like in practice, and is it a human-readable representation with a restricted vocabulary?
A13: DLP produces two related outputs:
- A complete discrete canvas , which is machine-compatible.
- A filtered human-readable anchor set , which is human-readable but intentially restricted.
After outputting these, ACD converts them and the planner-aware visual states into a free-text report.
We hope that our responses address your concerns. Please feel free to let us know if any questions remain, and we would be happy to provide further clarification.
Best,
Authors from Submission 10723
Follow-up comments to authors
Thank you very much for the in-depth rebuttal. Most clarity-related points are resolved/more understandble in the rebuttal, so I have confidence that the updated manuscript will read nicely. I will update the score accordingly. I still have not quite understood Q10: I understand that the [MASK] tokens need to be filtered out over time, but that it's not supposed to happen through an uncertain prediction. I also understand that by the end, the canvas is not allowed to contain [MASK] tokens. What happens if predictions for what to replace a [MASK] token with stay uncertain? Do you eventually allow an uncertain prediction to go in if there is no better alternative?
One issue I was going to re-raise from Q3 (but which has already been raised by another reviewer) is about the uncertainties and significance tests you conducted. Bootstrapping over the test set is a perfectly appropriate way of measuring aleatoric uncertainty, but says nothing about epistemic uncertainty, which you could measure by repeatedly training from different initializations. This perspective on training stability is especially pertinent because the proposed method is fundamentally different from previous report generation approaches. It's not always immediately clear which component dominates for a given method and dataset, which is precisely why one of the following would be appropriate:
- Rerunning the training a few times to derive an epistemic uncertainty estimate and update the significance claims, if necessary (significantly strengthens the paper, but may represent a greater time investment than available for the rebuttal).
- Listing this missing part of the significance as a limitation that potentially impacts statistical significance (still perfectly reasonable in my opinion).
Response to Follow-up Comments by Reviewer g8e3
Dear Reviewer g8e3,
We sincerely thank you for your prompt and constructive follow-up. We are highly encouraged to hear that our initial rebuttal has resolved your clarity-related concerns and that you are willing to update your score.
Below, we address your remaining questions regarding Q10 and Q3:
Q1: Regarding Q10: What happens if predictions for a
[MASK]token stay uncertain?
A1: To directly answer your question, while the diffusion decoding process does eventually force the replacement of all [MASK] tokens (typically via argmax at the final step), we do not allow an uncertain prediction to blindly go into the final report generation.
As detailed in Section 3.2 of our manuscript, the raw planner canvas is not directly fed into the autoregressive decoder. Instead, we render the predicted canvas into canonical phrases. Crucially, since not every candidate phrase is equally reliable, we apply a dedicated phrase scorer (Equation 9) to evaluate each candidate based on its local planner evidence and the context.
If a [MASK] token was resolved with high uncertainty at the final diffusion step, its corresponding aggregated planner state () will lack strong evidence, resulting in a low score . Consequently, this uncertain prediction is explicitly filtered out, and only confident phrases are kept as final anchors.
In short, if there is no confident alternative, our framework conservatively drops the uncertain anchor rather than forcing it into the prompt. This design prevents forced uncertain predictions from causing hallucinations in the downstream LLM generation.
Q2: Regarding Q3: Epistemic uncertainty and significance tests.
A2: We deeply appreciate your insightful distinction between aleatoric uncertainty (which our test-set bootstrapping measures) and epistemic uncertainty. You raise a very pertinent point—given the fundamental architectural differences between our non-autoregressive DLM-based planner and previous purely autoregressive RRG methods, understanding training stability across different initializations is crucial.
Given the time constraints of the current rebuttal phase, we will gladly adopt your second, very reasonable suggestion.
In the revised manuscript, we will expand the Conclusion section (Section 7), where we currently discuss limitations regarding our reliance on a pre-defined clinical ontology. We will explicitly add the absence of epistemic uncertainty estimation (e.g., via multi-seed retraining) as a limitation, noting that this omission potentially impacts the comprehensiveness of our statistical significance claims. We will also highlight evaluating the training stability of diffusion-based planners as an important direction for future RRG assessments.
Thank you again for your time, your rigorous review, and for providing such pragmatic and constructive paths forward. We are committed to incorporating these final refinements to strengthen the paper.
Sincerely,
The Authors
- Rating
- 3/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 2/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This work addresses the challenge of improving clinical faithfulness in chest X-ray report generation by reducing hallucinations and error accumulation in autoregressive vision-language models. The paper proposes ANCHOR-GEN, a hybrid framework that combines a Diffusion Language Model (DLM) as a structured planner with a standard autoregressive LLM decoder.
Strengths and weaknesses
Strengths:
- Novel use of diffusion models as structured planners. Instead of replacing LLMs with diffusion models, the paper uses DLMs in a more appropriate role: structured, iterative infilling over a discrete clinical canvas.
- The idea of representing medical knowledge as a structured field set (findings, severity, laterality, devices) improves interpretability and aligns well with clinical workflows.
Weaknesses:
- The paper includes a case study, but lacks systematic failure categories (e.g., rare diseases, ambiguous findings)
- The diffusion planner reduces hallucination in principle, but it also turns intermediate errors into explicit conditioning signals, which may make certain mistakes more rigidly propagated into the final report.
Questions
- What is the performance compared against a simpler structured planner (e.g., a single-step multi-label classifier)?
- The paper does not sufficiently demonstrate that diffusion is necessary. A strong multi-label classifier with iterative refinement or LLM-based structured prediction could serve as a competitive alternative.
Limitations
This paper increase the system compexity compared to baselines but only incur marginal improvements.
Formatting concerns
No
3 comments
Rebuttal
Dear Reviewer bP32,
We sincerely thank you for your appreciations on our novelty and interpretability, as well as the raised concerns and suggestions, which significantly strenthens the quality of this paper. In the followings, we offer further illustrations regarding your concerns.
Q1: The paper includes only one case study and lacks a systematic analysis of failure categories, including rare diseases and ambiguous findings.
A1: We sincerely thank the reviewer for pointing out the insufficient analyses on the current qualitative results, and would like to offer further illustrations for it.
Specifically in Tab. 2, we intend to intuitively compare our diffusion-based planner design compard to two representative baseline variants, i.e., one without any planner and another with a single-step, typical Transformer classifier (BERT-based).
Through qualitative comparisons, one can see that conventional Transformer-based classifiers obtain worse results, since they do not contain the mechansims of iterative denoising as the diffusion model does, therefore failing to calibrating the predicted plans during generation.
Yet, with the kind reminder from the reviewer, we notice that one case study might be insufficient, where we plan to add an additional case study for each used dataset to further illustrate this.
For your concerns regarding the rare diseases and ambiguous findings,
we would like analyze this based on our reported results in Tab. 2.
It is observed that Base mischaracterizes the severity and laterality of the effusions and omits the subtle vascular congestion.
The BERT planner recovers more pathological attributes but produces the contradictory statement, e.g., "No edema", indicating that conventional Transformer-based label prediction does not sufficiently preserve dependencies among coexisting findings.
In contrast, Anchor-Gen addresses challenging diagnoses with the best-performing accuracies, e.g., the uncertain status of consolidation, the preservation of the bilateral asymmetry, and the accompanying pulmonary vascular congestion.
Q2: The diffusion planner may convert intermediate prediction errors into explicit conditioning signals and rigidly propagate them into the final report.
A2: We agree that an explicit planner has the possibilities in propagating incorrect anchors if the bridge treats every prediction in a hard conditioning manner. Our method essentially avoids this in two ways. First, the phrase scorer filters candidate anchors using both the local planner state and the image-conditioned context , so that low-confidence canvas predictions are thus discarded. Second, GPMB uses a residual gate to constrain this in a soft conditioning manner, as is formulated in Eq. (10):
which selectively incorporates the planner states into the original image representation . Moreover, the planner diagnostics in Tab. 6 of our Appendix provide a direct evidence for this behavior, where this result presents:
| Variant | Field Acc.↑ | Anchor P↑ | Anchor R↑ | Usage↑ | Halluc. ↓ |
|---|---|---|---|---|---|
| +BERT Planner | 0.642 | 0.713 | 0.668 | 0.623 | 0.204 |
| +DLM Planner | |||||
| Full +GPMB | 0.746 | 0.811 | 0.798 | 0.824 | 0.091 |
In this rebuttal, we highlight the best-performing and second-best results of each table in forms of boldface and with underlines, respectively.
Compared with the single-step BERT planner (+BERT Planner), the DLM planner (+DLM Planner) reduces unsupported abnormal anchors by 38.2%.
Notably, adding GPMB (Full +GPMB) further reduces this rate by 27.8% while increasing anchor usage by 8.1%.
These results show that explicit planning does not simply constrain the use of clinical anchors. We will further refine this analysis in our final revision.
Q3: How does Anchor-Gen compare with a simpler structured planner, such as a single-step multi-label classifier?
A3: We would like to kindly point that this comparison is included in Tab. 1, but we agree that its role should be made more explicit, where we present its results in the following table:
| Planner | B@1 ↑ | B@2 ↑ | B@3 ↑ | B@4 ↑ | MTR ↑ | R-L ↑ | CE P ↑ | CE R ↑ | CE F1 ↑ |
|---|---|---|---|---|---|---|---|---|---|
| +Trans. Planner | 0.260 | 0.179 | |||||||
| +LLM Planner | 0.388 | 0.254 | 0.177 | 0.126 | 0.170 | 0.281 | 0.460 | 0.477 | 0.468 |
| +BERT Planner | 0.392 | 0.123 | 0.169 | 0.284 | 0.423 | 0.414 | 0.418 | ||
| +DLM Planner (Ours) | 0.427 | 0.266 | 0.186 | 0.151 | 0.177 | 0.335 | 0.616 | 0.609 | 0.612 |
Specifically in this table, the +BERT Planner row refers to the requested single-step multi-label planner, which uses the same image input and report decoder but predicts clinical fields in one pass rather than denoising a masked canvas.
It is observed that the single-step classifier (+BERT Planner) is weaker not only on clinical accuracy metrics (e.g., CE metrics), but also on the planner-specific metrics shown in A2.
In particular, DLM planning (+DLM Planner) improves field accuracy by 14.3% and anchor recall by 16.9%, while reducing unsupported anchors by 38.2%.
To further clarify this point, we will revise Sec. 5 to explicitly state that +BERT Planner refers to the single-step multi-label classifier requested by the reviewer.
Q4: The paper does not sufficiently demonstrate that diffusion is necessary relative to a strong multi-label classifier with iterative refinement or an LLM-based structured predictor.
A4: We would like to kindly point out that these results are already included in our previous submitted paper.
Specifically, the bottom rows of Tab. 1 show our direct comparison with DLM-based planner (+DLM Planner) and three typical types of classifier designs, i.e., vanilla Transformer-based planner (+Trans. Planner), LLM-based planner (+LLM Planner), and BERT-based planner (+BERT Planner).
Besides, we also report several anchor-specific metrics to analyze the behaviors of our planner design, as is reported in Tab. 6 of our Appendix.
Note that these two results are also presented and discussed in A2 and A3, where we wish this additional illustrations can address the concerns from reviewers.
We hope that our responses address your concerns. Please feel free to let us know if any questions remain, and we would be happy to provide further clarification.
Best,
Authors from Submission 10723
Gentle Follow-up on Our Rebuttal
Dear Reviewer bP32,
We sincerely thank you for your time and the constructive feedback you provided in your initial review, which has been highly valuable in improving our manuscript.
We are writing to gently follow up on our rebuttal. We have carefully addressed your concerns and provided the requested clarifications in our response. As the author-reviewer discussion phase is actively underway, we wanted to kindly check if our rebuttal has successfully resolved your questions.
If there are any remaining concerns, or if you require any further clarifications or details, please do not hesitate to let us know. We remain fully available and are more than happy to continue the discussion to address any additional points you might have.
Thank you again for your valuable time, rigorous evaluation, and contribution to this review process.
Sincerely,
Authors from Submission 10723
Final Gentle Follow-up: Approaching the Discussion Deadline & Review Updates
Dear Reviewer bP32,
We hope you are having a good week.
As the author-reviewer discussion period is drawing to a close very soon, we wanted to send one final, gentle follow-up regarding our rebuttal. We have worked carefully to address the valuable points raised in your initial review, and we sincerely hope our detailed response has successfully resolved your concerns.
We also wanted to briefly share that, following the ongoing discussions, the other reviewers have responded positively to our rebuttals and updated their scores accordingly. We are highly encouraged by this positive momentum and consensus. We deeply value your original feedback, and we hope that our dedicated revisions provide you with the same level of confidence in our manuscript.
If you have any remaining questions or if there is any further clarification we can provide before the system closes, please do not hesitate to let us know. We are fully available to provide prompt responses.
Thank you once again for your time, your expertise, and your contribution to improving our work.
Sincerely,
Authors from Submission 10723
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Response to the Area Chair x45V
Dear Area Chair x45V,
We sincerely thank you for carefully summarizing the contributions and major concerns raised during the review process. In the following texts, we would like to provide a detailed point-by-point indication for your raised concerns in the meta-review to our detailed reviewer-specific responses:
We hope that this elaboration makes the correspondence between the meta-review concerns and our detailed responses easier to follow. Please feel free to let us know if any questions remain, and we would be happy to provide further clarification.
Best,
Authors from Submission 10723