SENSE: Semantic Neural Speech Synthesis from Brain Dynamics via Spatial Graph Encoding
Jisoo Park, Seonghak Lee, Hyojin Park, Junseok Kwon
NeurIPS 2026
TL;DR. SENSE reframes EEG-to-speech as a joint acoustic-semantic task, combining a graph-based EEG encoder with congruency-restricted CLIP alignment.
Abstract. Reconstructing speech from non-invasive brain signals offers a promising pathway for restoring communication in individuals who are cognitively intact but unable to speak. Existing EEG-to-speech approaches formulate this task as acoustic reconstruction, optimizing waveform fidelity while ignoring whether the generated speech preserves high-level semantic content. In this work, we revisit this formulation and argue that EEG signals carry not only acoustic but also semantic information. We identify two key limitations of prior methods: (1) the neglect of spatial relationships between EEG electrodes, and (2) the failure to exploit the semantic structure of the N400 paradigm, where congruent and incongruent trials reflect distinct semantic processing. We propose SENSE (Semantic-EEG Neural Speech SynthEsis), which combines a graph-based EEG encoder over electrode geometry with EEG Semantic Conditioning (ESC), aligning EEG to a pretrained semantic space using only congruent trials. On the N400 dataset, SENSE consistently outperforms prior methods on both acoustic and semantic metrics, and model-internal channel attribution suggests distributed reliance on auditory, sensorimotor, and centro-parietal regions, consistent with known speech-perception neuroscience. In the unseen-subject setting, SENSE trained on only two subjects already surpasses the strongest baseline trained on all eighteen subjects in word error rate, and matches it on acoustic metrics with as few as eight subjects.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 5 reviews · OpenReview
Updated 25 Nov 2026, 03:45 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
This paper proposes SENSE, an EEG-to-speech generation framework that introduces semantic conditioning through ESC. Reviewers acknowledge the importance of EEG-based speech decoding and find the approach technically interesting, with improvements over existing baselines.
The main concerns are insufficient validation of semantic preservation, limited generalization, and evaluation rigor. Reviewers question whether the current results support the claim that SENSE preserves semantic content, given the high WER and limited gains in semantic metrics. The role of ESC is also not fully validated, as current ablations do not demonstrate that EEG-derived semantic representations capture trial-specific meaning.
Additional concerns include the restrictive N400 congruent-only setting, lack of naturalistic speech evaluation, missing human evaluation, potential data leakage, and fairness issues in training comparisons.
Final justification
The authors have addressed several of the reviewers' major concerns, and all the reviewers' final ratings are positive. The paper proposes a valuable EEG-to-speech generation framework and achieves state-of-the-art performance. I vote to accept the paper.
Read meta-review
Meta-review
This paper proposes SENSE, an EEG-to-speech generation framework that introduces semantic conditioning through ESC. Reviewers acknowledge the importance of EEG-based speech decoding and find the approach technically interesting, with improvements over existing baselines.
The main concerns are insufficient validation of semantic preservation, limited generalization, and evaluation rigor. Reviewers question whether the current results support the claim that SENSE preserves semantic content, given the high WER and limited gains in semantic metrics. The role of ESC is also not fully validated, as current ablations do not demonstrate that EEG-derived semantic representations capture trial-specific meaning.
Additional concerns include the restrictive N400 congruent-only setting, lack of naturalistic speech evaluation, missing human evaluation, potential data leakage, and fairness issues in training comparisons.
Final justification
The authors have addressed several of the reviewers' major concerns, and all the reviewers' final ratings are positive. The paper proposes a valuable EEG-to-speech generation framework and achieves state-of-the-art performance. I vote to accept the paper.
- Rating
- 5/6
- Confidence
- 5/5
- Quality
- 4/4
- Clarity
- 4/4
- Significance
- 4/4
- Originality
- 4/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper proposed a method to convert EEG signal into speech. The proposed method relay on the semantic information it the EEG siganl and use two important prior information:
- The spatial resolution between EEG electrodes, and
- The semantic structure of N400 paradigm.
The proposed method which called SENSE (Semantic-EEG Neural10Speech SynthEsis), combine gaprh based EEG encoder with EEG Semantic Conditioning (ESC). The results of the proposed method outperforms pervious method in semantic and acoustic metrics. The proposed method train only on two subjects which get better results than state of the art results baseline trained on all eighteen subjects in terms of WER (word error rate), and matches it on acoustic metrics when using 8 subjects for training
They also test it on unseen subjects and shows very good generalisation capabilities.
Strengths and weaknesses
Strengths:
-
The proposed method get very good results on cross subjective tests, trained only on two subjects and get better results than method that trained on all 18 subjects. Furthrmore when trained on 8 subjects it matches state of the art baselines.
-
The proposed method use EEG semantic conditioning ESC with the N400 in order to improve the results.
-
Using coordinate garph neural networks with convolutions networks is very good since the model preserve the geometry nature of the signal and can map it with semantic manner.
-
The proposed method run comprehensive ablation analysis, which test each component in the proposed network - GNN, CNN skip, channel attention, ESC, CTC and show that each one contribute to the overall performance.
-
The proposed method employs a very good training strategy that uses random dropping of the EEG embedding and Classifier-Free Guidance. This is a way to ensure that the decoder can synthesize speech without text at inference.
Weaknesses:
-
The proposed method work on grid with the graph neural network, since it use small amount of pairs - 7200 it can lead to overfit. Please try to use larger amount of pairs for training in order to improve the results.
-
The word error rate (WER) is very close to 1 which is very bad results. The model should get much better semantic results when it test the WER score
-
The proposed method trained on the N400 paradigm, this is good dataset but doesn't simulate real conversational speech. Find real speech datasets which give us good clue how the model perform.
-
The paper lacks human evaluation - Mean Opinion Score (MOS), which tests the acoustic capabilities of the model. The ASR metric is very good but it only tests the semantic information of the proposed model.
-
Fairness - The proposed method trained for 200k iterations, whereas the previous baseline trained for 100k iterations. The authors should provide a comparison of the loss curves to clarify the source of the improvement.
Questions
See weaknesses:
-
Please address the overfit issue. Try to train the model on larger datasets with more pairs. I think that it will give much better results in the proposed model.
-
Try to solve the problem which the WER is close to 1. Currently WER of 100% is very high and current deep learning approches get better results on the WER score.
-
Please train on more real datasets not only on the N400 paradigm. Find real speech datasets which give us good clue how the model perform.
-
What is the MOS metric of the proposed model? you should run human evaluation - Mean Opinion Score, which tests the acoustic capabilities of the model.
-
Fairness - What is the results of the proposed model when trained on 100k iteration? does it still get better results than the baselines which train on the same amount of compute?
Limitations
yes
Final justification
Thank you for the answer and the rebuttal and adding new experiments.
It is good to know that SENSE get better results in 100k iteration which show training fairness.
I also find the naturalistic-speech experiment interesting since it shows that the representations can be transfer beyond N400 setting.
The DNSMOS results are informative but cannot replace real MOS experiment.
Overall, the author answer strengthens my evaluation and I would like to maintain my score.
Formatting concerns
No
3 comments
Thank you for the answer and the rebuttal and adding new experiments.
It is good to know that SENSE get better results in 100k iteration which show training fairness.
I also find the naturalistic-speech experiment interesting since it shows that the representations can be transfer beyond N400 setting.
The DNSMOS results are informative but cannot replace real MOS experiment.
Overall, the author answer strengthens my evaluation and I would like to maintain my score.
Thank you very much for your thoughtful follow-up evaluation and for taking the time to read our rebuttal and additional experiments. We sincerely appreciate your positive feedback regarding the training fairness analysis and the naturalistic-speech experiment. We also agree that DNSMOS cannot replace a human MOS evaluation, and we will clarify this limitation in the final version.
Thank you again for your constructive comments and for maintaining your evaluation. We truly appreciate your careful review.
- Rating
- 4/6
- Confidence
- 2/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 2/4
- Contribution type
- general
- Ethical concerns
- CLEAR MAJOR CONCERN: Check this box if there is a clear, major concern for which you do not need further clarifications. Detail the concern in the Strengths and Weaknesses section. Use another option below if you would benefit from a consultation with an expert., Major Concern: Human rights (including surveillance)
Read review
Summary
This paper presents an incremental technical exploration on EEG-to-speech decoding. Results seem convincingly above the previous baseline, although with relatively small improvements, as necessarily bounded by a small training dataset.
Strengths and weaknesses
Strengths:
- Care of the specificity of the training dataset to improve the training procedure.
- Reasonable motivation of the approach.
- The author attempts to make an engineering demonstration; this demonstration is data-bounded at the moment. Scaling curve look promising.
Weaknesses:
- The attempt to decode speech from EEG raises ethical concerns (discussion in limitations).
- Stimuli used in this dataset are clearly out of distribution, limiting the translation to real-world use. Notably quoting the N400 paper "To do so, individual words from the word list were recorded from a female speaker, instructed to voice the words with minimal inflection, stress, and intonation (i.e. in a monotonous non-prosodic manner). Words were then compiled into complete sentences using the Audacity Software [...] time gaps of 10 ms were added between words so that all sentences would have similar pacing and that researchers would be able to trigger discretely on each word in future work. Both artificial timing and frequency add to the robotic nature of the stimuli. A future initiative will add the prosodic versions of these sentences to this public stimulus set so that researchers can explore more communicative aspects of language."
- The attempt to inform decoder with semantic information is not particularly novel.
Minor weaknesses:
- Lots of repetition in the introduction.
Questions
- I am not sure what the WER metric is here; if this is the "word error rate" then the worst score should be 1 (all words wrongly predicted).
- Are the best examples provided from the training set?
- What range of scores would make the method usable? How can they adapt their conclusion based on that? Could a baseline achieved with ecog data and MEG data be added for the sake of comparison?
Limitations
This paper justifies its engineering approach to decoding listened speech as "current EEG-to-speech systems require active listening to external stimuli and controlled lab settings, limiting misuse risk". Nonetheless:
- The evidence for the active listening argument is not given. Could the author indicate a study that has compared the decoding performance of subject that are task-distracted vs task-engaged? If such data were to be available, an ethical approach to the matter would require the author to show that their new decoder does not improve decoding on task-distracted trials beyond what is acceptable.
- EEG is a much more portable system than MEG or fMRI, and requires much less invasive operation than EcOG; consequently, it seems well positioned to be used beyond the lab settings, posing a large ethical threat.
Formatting concerns
- Some abbreviations are not explained (EEG, MEG)
4 comments
Rebuttal
We appreciate the reviewer’s thoughtful comments. We agree that several claims, particularly regarding ethics and generalization, should be stated more carefully.
W1. Task scope and ethical concern
SENSE addresses listened-speech decoding from externally presented speech. It does not evaluate imagined speech, inner speech, self-generated language, or unexpressed intentions. The present results should therefore not be interpreted as private-thought decoding.
We also agree that our claim that active listening limits misuse risk was not sufficiently supported. In the N400 dataset, participants listened to the presented sentences as part of the experimental task. The dataset does not include distracted or non-engaged listening, so we cannot directly perform the engaged-vs-distracted comparison suggested by the reviewer.
Prior semantic decoding work has examined attention in the context of mental privacy. Using fMRI, Tang et al. [2] found that semantic decoding was substantially stronger for attended than unattended speech in a multi-speaker setting, and that successful decoding depended on subject cooperation. Motivated by this analysis, we examined whether the SENSE representation also differs between attended and unattended speech.
We applied the frozen N400-trained EEG encoder and ESC projection to the Broderick Cocktail Party dataset [1], without adaptation to this dataset. Participants heard two speech streams simultaneously and attended to one of them. We separately evaluated retrieval of the attended and unattended speech.
| Target speech | MRR | Chance MRR | MRR |
|---|---|---|---|
| Attended | 0.0478 | 0.0325 | +0.0153 |
| Unattended | 0.0655 | 0.0702 | -0.0048 |
Because the candidate pools differ in size, the raw MRR values are not directly comparable. We therefore compare retrieval with the chance level of each pool. Attended-speech retrieval exceeded its chance level, whereas unattended-speech retrieval did not.
This suggests that the frozen representation preserves less retrievable information about the unattended speech stream than the attended stream. However, this is a representation-level test of selective attention, not a test of speech reconstruction during complete disengagement. We cannot directly evaluate speech reconstruction under these conditions because paired speech targets are unavailable in this dataset. These results suggest that attention affects the information captured by the SENSE representation, but are not sufficient to establish active listening as a reliable safeguard. We will revise this claim and identify distracted or non-engaged decoding as an open safety question.
We also agree that EEG portability should not be treated as protection against misuse. Portable recording may instead increase privacy risks outside controlled settings. We will revise the Broader Impact section to discuss consent, protection of neural data, and unauthorized use more explicitly.
W2. Controlled and artificial stimuli
We agree that the N400 stimuli are monotonous, artificially segmented, and different from natural speech. We used this corpus because it supports comparison with existing EEG-to-speech models, provides controlled sentence-final congruency labels, and enables reliable EEG–stimulus alignment.
To examine whether the learned representation can be adapted beyond this setting, we fine-tuned the N400-trained encoder and ESC projection on the Broderick naturalistic speech dataset [1], where participants listened to continuous narrative speech. We aligned each EEG segment with its corresponding text representation and compared the cosine similarity of matched EEG-text pairs with randomly mismatched pairs.
| EEG-text pairing | Cosine similarity |
|---|---|
| Matched | 0.602 |
| Random | 0.517 |
The matched similarity was higher for all 19 participants, and none of the 5,000 random permutations produced a similarity gap as large as the observed gap (+0.085). These results suggest that the learned representation can be adapted to EEG recorded during continuous natural speech, beyond the artificial N400 stimuli. This experiment evaluates representation-level alignment rather than waveform reconstruction because the public release available to us does not provide the aligned speech waveforms required for reconstruction.
W3. Scope of novelty
We agree that providing semantic information to a decoder is not novel by itself. Our contribution is to learn an EEG-derived sentence-level representation through ESC and combine it with electrode geometry-aware encoding for EEG-to-speech generation.
Our additional analyses provide direct evidence that contains sentence-specific information in the semantic embedding space. For each EEG trial, similarity to the matched sentence embedding was higher than to mismatched sentences (0.37 vs. 0.25), with a larger gap for congruent trials (0.40 vs. 0.25). The matched sentence was also retrieved above chance from a 440-sentence candidate set. Full results are reported in our response to DYe3, W3(a)–(b).
Questions:
1. Why can WER exceed 1?
WER is defined as
where , , and denote substitution, deletion, and insertion errors, and is the number of reference words. Insertions can make the total number of errors exceed , so WER is not upper-bounded by 1. We will clarify this in the evaluation section.
2. Are the best examples from the training set?
No. All qualitative examples come from the held-out test set. We selected the top 20% of congruent test samples based on SENSE’s per-sample WER, and chose the main paper examples from this subset. We will clarify this selection criterion. Appendix A.7 shows additional examples randomly drawn from the same subset.
3. Usability and comparison with ECoG/MEG.
There is no established score threshold for usable EEG-to-speech decoding. The current reconstructions are not reliably word-intelligible, so we do not claim practical usability. We will revise the conclusion to make this clearer.
Direct numerical comparison with ECoG or MEG systems is difficult because they often address different decoding tasks. For example, ECoG work has synthesized speech from invasive recordings during speech production [3], whereas non-invasive work has evaluated retrieval of perceived speech segments from M/EEG recordings [4]. We will discuss these results as context, but not treat their reported scores as directly comparable baselines.
Minor comments:
We agree that some abbreviations are not defined at first use and will correct this in the revision. We will also reduce the repetition in the introduction.
References
[1] Broderick et al., "Electrophysiological correlates of semantic dissimilarity reflect the comprehension of natural, narrative speech," Current Biology, 2018.
[2] "Semantic reconstruction of continuous language from non-invasive brain recordings." Nature Neuroscience 26.5 (2023): 858-866.
[3] “Speech Synthesis from Neural Decoding of Spoken Sentences”, Nature 568, 493–498, 2019.
[4] “Decoding Speech Perception from Non-Invasive Brain Recordings”, arXiv preprint arXiv:2208.12266
Thank you again for your thoughtful and constructive feedback. We hope that our responses and additional analyses address the concerns raised in the review. If any questions or concerns remain, we would be happy to provide further clarification or continue the discussion.
Response to rebuttal
I would like to thank the author for addressing my concerns, including the novel evaluations on the Broderick dataset.
I will maintain my score as it is now because the decoding gain remains small, although significant and well demonstrated. Please note that I have never run decoding from EEG data; instead being a specialist in MEG, fMRI, and ECoG, so my assessment might be slightly off here. I therefore maintain my confident score of 2. An extension of the approach to MEG or ECoG datasets could have helped me to be further confident in assessing this new technique.
I would also like to thank the author for acknowledging the poverty of their initial argument regarding the ethical concerns and taking the time to rephrase them. I think we will all benefit from progressively developing solid ethical values and practices when it comes to neural decoding.
We thank the reviewer for revisiting our response and for the thoughtful comments.
We appreciate the assessment that the additional Broderick evaluations and the decoding gains are significant and well demonstrated, while acknowledging that the absolute gains remain modest.
We agree that extending the approach to MEG or ECoG datasets would provide useful evidence on its applicability across recording modalities. Although such an evaluation is beyond the scope of the current work, we will discuss it as an important direction for future study.
We also appreciate the reviewer’s comments on the ethical discussion. We will incorporate the revised framing and safeguards described in our response into the final version.
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 2/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This work proposes a novel approach for EEG-to-speech synthesis by introducing SENSE, a model that reconstructs speech waveforms from 128 channel EEG recordings. Interestingly, it does it from EEG recordings that happened during passive listening not speaking (from the N400 corpus). SENSE has three main contributions: (i) formulating the problem of EEG-to-speech to incorporate acoustic and semantic information, not just acoustic. (ii) a framework that is structure-aware by having a graph-based EEG encoder and semantic-aware trough EEG Semantic Conditioning (ESC) that aligns EEG latents to a frozen CLIP text embedding of the stimulus sentences. (iii) SENSE train everything end-to-end using careful design and training of the decoder showing strong cross-subject generalization and generated quality that beats several baselines. The paper tests design choices rigorously well showing the effect of each loss term and model component, which raises the confidence in the final model choices.
Overall, the architecture shows careful engineering and design, and the cross-subject generalization is an important well-tested results, despite being a hard problem for EEG due to low signal-to-noise ratio. However, despite the rigorous ablations, the paper’s claim of semantic content recovery is still under-supported for two main reasons: a) every output still sits in an unintelligible regime (WER ≈ 1.0, STOI ≈ 0.40, MCD ≈ 10 dB), and more importantly, b) the important controls that would show ESC transfers per-trial meaning are absent (see weaknesses for more details).
Strengths and weaknesses
Strengths:
- T1: Cross-subject generalization. Strong and carefully tested generalization capability on all metrics and several pairs. This is one of the paper’s strongest points, especially since the used training dataset is not big.
- T2: Rigorous ablations and easy reproducibility. Thorough ablations on each model component and hyperparameters. The paper does a very careful job in validating each design components on all important metrics, even text alignment choices like using CLIP vs other alternatives are included and analyzed well. The code is also provided in the supp material to reproduce the results.
- T3: Careful semantics aware design. The paper builds well on literature with novelty that shows deep understanding of the problem. ESC and Congruency-restricted semantic alignment and how it is integrated into the framework especially during training is a novel idea that has real benefits in making use of the setup and dataset available. Structure-aware design via graph adjacency and making use of all input electrodes is also a strong point that gives the model more information and makes it more interpretable. This is clearly shown throughout the results and also Fig. 7 attributions. However, all of this supports the spatial claim (i.e., that the model uses EEG channels besides the acoustic ones), but it doesn’t confirm any substantial improvement in the semantic content (see weaknesses).
Weaknesses:
- W1: Results remain unintelligible. Despite the careful design of ESC and objective, the model has WER ≈ 1.0, STOI ≈ 0.40, MCD ≈ 10 (Table 1), which means the output is still not word-intelligible. While the authors discuss this and while the model beats baselines on those metrics, the evidence for the claim that SENSE "preserves semantic content" is weakly supported by these results. Even the qualitative results (Fig. A.3) show that the semantics of the produced sentences are not preserved. Moreover, the improvements in the BERT and CLIP-sim scores are modest among baselines. Thus, while SENSE has a clear advantage over the baselines in some metrics, the claim that it has better semantics is still not clear given these results. The authors here need to either make the claim more precise and focused on the model’s true strengths or show more evidence of semantics (see next point).
- W2: Semantic content in the model results is not measured well. As mentioned above, semantic content of the outputs is not shown to improve much. There is only evidence that the model outputs are fluent not necessarily semantically matching the GT. Moreover, the used semantics metrics like BERTScore is known to be inflated. Without proper controls like randomized trails or a more accurate measure like rescaled BERTScore, it doesn’t reflect clear improvements. Also, the authors don’t mention whether the SENSE-vs-baseline deltas statistically significant anywhere in the paper.
- W3: ESC role remains poorly-tested. ESC ablation (Table 2) shows ESC helps the whole pipeline, not that it transfers per-trial meaning; Fig. 7 of the channel-attribution shows that the model uses other channels besides acoustic ones, not that it utilizes semantics. So the claim of utilizing "not only acoustic but also semantic" is not tested well. ESC's value rests on g_eeg transferring per-trail meaning, but there is no test that it does. Finally some baselines are missing to prove the claims about ESC: (a) g_clip conditioning, condition on the true g_clip and a mismatched g_clip at inference to quantify where does g_eeg lies. If g_eeg is close to the mismatched g_clip (i.e., wrong sentences) and far from the true g_clip, then ESC failed to make g_eeg carry meaning. Moreover, the numbers themselves are important to see whether the semantic metrics indicate intelligible speech or not. (b) shuffled/mismatched conditioning, i.e., condition on another trial's text (or the mean embedding) at inference; if metrics barely move, ESC is not a semantic channel. (c) semantic retrieval, asking: does the trained g_eeg recover the correct sentence's embedding above chance?
- W4: Congruency setup is too restrictive. Despite ESC being done only on congruent trails and the many design choices that go to ensure that for the purpose of preserving semantic content, there doesn’t seem to be congruent-only vs all-trials comparison, and so we have no evidence the restriction itself is the useful part. Unless, there is something I don’t understand, this seems to be an essential baseline to test. Moreover, this design choice, even if it was as useful as claimed, it restricts the problem too much, making it possible to train SENSE on datasets that are only similar to N400. This precludes any naturalistic EEG datasets and make it not possible to actually test whether SENSE can perform much better in semantic content with more data. I know the authors disclose this in the limitations and cross-dataset training is a much more involved problem, but catering the design to only one dataset with no clear advantage undermines the utility of the method. Can the authors answer whether the pipeline could be possibly used for another setup with any slight variation from N400, not necessarily a fully naturalistic stimuli? If not, then the method however good remains too restricted, especially that it can’t even utilize massive EEG datasets out there for anything, even pre-training the encoder.
Minor:
- Limited discussion of relevant literature. While not addressing the same problem, discussion of EEG foundation models is limited despite being relevant to handling the problems with using cross-trail and even cross-dataset EEG channels like [1, 2]. They also provide a good encoder that might be useful instead from training from scratch.
- Preventing sentence leakage. The N400 corpus reuses sentence frames; can the authors explain how do they prevent any framing leakage to the held-out testset?
- Imprecise semantics claim in the abstract. In the abstract, the authors mention that “EEG signals carry not only acoustic but also semantic information.” However, for N400, we know from several previous work that it does include semantics. The more precise framing is that the proposed method utilizes these semantics during EEG-to-Speech generation.
[1] NeuroLM: https://arxiv.org/pdf/2409.00101
[2] Diver-0: https://arxiv.org/abs/2507.14141
Questions
See weaknesses above, they entail the needed questions and baselines, including even minor clarifications. While I believe the claims made in this work need more support, I remain open to clarifications and suggestions from the authors that would resolve my doubts or correct any misunderstandings.
Limitations
yes
Final justification
I find the generalization beyond the N400 dataset as well as the rescaled BERT score and retrieval results to be very helpful in addressing many of the concerns convincingly.
However, I think my reservation regarding the model semantics are still not fully resolved, especially since the mismatched and matched g_clip scores are not very different from each other. This is further supported by the modest inference time results. Therefore, I still believe that the semantics claims and the intelligibility claims made in the paper need serious reframe to state precisely what the results support.
So, conditional on the authors' promise to reframe this more precisely and consistently across the paper, posing it as a starting point not as a practical semantic speech decoding setup (and reporting W3 d and c results transparently in the paper), I think a score of 4 is justified here.
Formatting concerns
None
4 comments
Rebuttal
We thank the reviewer for detailed and valuable feedback. Following the reviewer’s questions, we examine reconstruction intelligibility, per-trial EEG-text correspondence, and the functional role of ESC.
W1. Reconstruction intelligibility and semantic claim
We agree that WER close to 1 means that the current reconstructions are not yet reliably word-intelligible, and we do not claim practical speech decoding at this stage. We will revise wording such as “preserves semantic content” where it could imply reliable recovery of sentence meaning, while retaining the claim that SENSE improves sentence-level semantic similarity relative to the evaluated baselines.
The reviewer asks for stronger evidence that this improvement reflects semantic information. We provide this below: W2 shows significant gains in rescaled BERTScore; W3(a)–(b) show trial-specific EEG-text correspondence through matched-vs-mismatched similarity and sentence retrieval; and W3(c)–(d) test the functional role of ESC, separating inference-time conditioning from its training-time contribution.
We will present Fig. A.3 as qualitative examples rather than direct evidence of semantic preservation.
W2. Semantic metrics and statistical significance
The reviewer asks for rescaled BERTScore, mismatched control, and statistical testing of the SENSE-vs-baseline differences. We recomputed BERTScore with baseline rescaling for all models and tested the 800 paired sample-level differences using a two-sided Wilcoxon signed-rank test (statistical significance), after averaging each metric over five inference runs. A corresponding trial-mismatch control is provided in W3(a).
| Metric | SENSE | FESDE | FE-Phoneme | vs. FESDE: () | vs. FE-Phoneme: () |
|---|---|---|---|---|---|
| MCD | 9.928 | 11.735 | 10.649 | () | () |
| STOI | 0.413 | 0.274 | 0.381 | () | () |
| WER | 0.995 | 1.217 | 1.123 | () | () |
| BERTScore (rescaled) | 0.096 | 0.018 | 0.047 | () | () |
| CLIP-Sim | 0.765 | 0.756 | 0.758 | () | () |
SENSE significantly outperforms both baselines on all five metrics. Rescaling makes the differences in BERTScore clearer, while the controls in W3 test whether the semantic correspondence is trial-specific.
W3. Per-trial meaning and the role of ESC
We agree that the original ESC ablation establishes an overall benefit, but does not by itself establish that carries trial-specific meaning. Fig. 7 likewise demonstrates the use of non-auditory channels rather than semantic utilization. We therefore added the following controls on and its effect on generation.
(a) Representation-space control.
For each trial, we compared cosine similarity to the true with the mean similarity to the other 439 sentence embeddings among 440 candidates.
| Evaluation subset | Similarity to true | Mean similarity to mismatched | Gap | ||
|---|---|---|---|---|---|
| All trials | 800 | 0.37 | 0.25 | +0.12 | |
| Congruent trials | 400 | 0.40 | 0.25 | +0.15 |
The true-vs-mismatched gap is significant in both subsets and is numerically larger for the congruent trials used for ESC supervision.
(b) Sentence retrieval.
Using the 400 held-out congruent trials as queries, we ranked all 440 unique sentence embeddings.
| Evaluation | Top-1 | Top-10 | Top-20 |
|---|---|---|---|
| Congruent trials () | 2.8% | 15.5% | 23.0% |
| Random chance | 0.23% | 2.27% | 4.55% |
While the absolute retrieval accuracy remains modest, retrieval is above chance at all cutoffs, providing further evidence of trial-specific EEG-text correspondence.
(c) Conditioning intervention.
We replaced at inference with either the matched or a mismatched , while keeping all other inputs fixed. Mismatches were created by a deterministic cyclic shift with no self-pairs.
| Conditioning | MCD | Mel-Corr | BERTScore (rescaled) |
|---|---|---|---|
| 9.942 | 32.14 | 0.096 | |
| Matched | 9.778 | 32.81 | 0.097 |
| Mismatched | 9.919 | 32.14 | 0.092 |
BERTScore follows the expected ordering of matched, EEG-derived, and mismatched conditioning, whereas the acoustic metrics do not show the same consistent ordering. This behavior suggests that conditioning identity is reflected more clearly in sentence-level semantic quality than in acoustic reconstruction, consistent with ESC providing sentence-level semantic conditioning rather than simply improving acoustic reconstruction.
(d) Inference-time vs. training-time effects.
To separate the two effects, we first replaced with the learned null embedding in the ESC-trained model. We then compared the ESC-trained and no-ESC models under the same null conditioning.
| Effect tested | Comparison | Mel-Corr | BERTScore (rescaled) |
|---|---|---|---|
| Inference-time conditioning | ESC-trained: vs. null | +0.11 | +0.002 |
| Training-time ESC | Null-conditioned: with ESC vs. without ESC | +2.38 | +0.004 |
Replacing with the null embedding decreases BERTScore, supporting a modest inference-time semantic effect. The ESC-trained model also remains better under null conditioning, showing an additional training-time contribution. Because the ESC loss backpropagates through into and the EEG encoder, we interpret this training-time benefit as representation shaping.
Taken together, these analyses indicate that ESC shapes the EEG representation during training and provides modest semantic guidance during inference. We will revise the Method to distinguish these two roles more clearly.
W4. Generalization beyond the N400 paradigm
SENSE is not structurally tied to the N400 paradigm: the graph-temporal encoder operates on multichannel EEG, and ESC requires paired EEG-text samples rather than a congruency label. In our main experiments, congruency is used to select cleaner sentence-level supervision for ESC.
To test whether ESC itself requires congruency labels, we trained the same model by applying ESC to all trials rather than only congruent trials.
| ESC supervision | MCD | Mel-Corr | STOI | WER | BERTScore (rescaled) |
|---|---|---|---|---|---|
| Congruent trials only | 9.93 | 32.07 | 0.413 | 0.995 | 0.096 |
| All trials | 10.17 | 30.90 | 0.409 | 1.018 | 0.094 |
| Without ESC | 10.34 | 29.43 | 0.401 | 1.032 | 0.090 |
Applying ESC to all trials improves all five metrics over removing ESC. This shows that congruency labels are not required for ESC to provide useful sentence-level supervision. Restricting ESC to congruent trials further improves all metrics, suggesting that congruency is useful as a dataset-specific supervision filter rather than an architectural requirement.
To further evaluate transfer beyond the N400 paradigm, we initialized the encoder with the N400-trained weights and fine-tuned it on the Broderick Natural Speech dataset [3], which contains continuous listened-speech EEG and text, while the public release available to us does not provide the aligned speech waveforms required for reconstruction. We therefore evaluated transfer at the representation level using EEG-text cosine similarity.
| Dataset | Matched similarity | Random similarity | Gap |
|---|---|---|---|
| Broderick | 0.602 | 0.517 | +0.085 |
The matched-over-random gap was positive for all 19 participants and exceeded all 5,000 random permutations (). This shows that the encoder and ESC objective can be adapted to continuous listened-speech EEG without an N400 manipulation.
Minor comments:
1. EEG foundation models. We agree that NeuroLM [1] and DIVER-0 [2] could provide pretrained encoder initializations. Because neither evaluates listened-speech waveform reconstruction, we will discuss them as relevant initialization strategies rather than direct task baselines.
2. Sentence-frame leakage. We did not enforce sentence-frame disjointness. The unseen-subject split reuses stimuli by design, while the unseen-audio and unseen-both splits are exact-sentence-disjoint but share 35/38 sentence frames with training, differing in the final word. We will clarify that these splits test unseen complete sentences, not entirely unseen frames.
3. Abstract wording. We agree that N400 semantics are established rather than a contribution. We will revise the abstract to: “SENSE uses the semantic congruency known to be present in the N400 paradigm as sentence-level supervision for EEG-to-speech representation learning.”
References
[1] “NeuroLM”, arXiv preprint arXiv:2409.00101
[2] “DIVER-0”, arXiv preprint arXiv:2507.14141
[3] Broderick et al., "Electrophysiological correlates of semantic dissimilarity reflect the comprehension of natural, narrative speech," Current Biology, 2018.
Thank you again for your thoughtful and constructive feedback. We hope that our additional experiments and analyses help clarify our contributions and address the concerns raised in the review. If any questions or concerns remain, we would be more than happy to provide further clarification or continue the discussion.
I would like to thank the authors for their thorough rebuttal and detailed addressing to each question. I find the generalization beyond the N400 dataset as well as the rescaled BERT score and retrieval results to be very helpful in addressing many of the concerns convincingly.
However, I think my reservation regarding the model semantics are still not fully resolved, especially since the mismatched and matched g_clip scores are not very different from each other. This is further supported by the modest inference time results. Therefore, I still believe that the semantics claims and the intelligibility claims made in the paper need serious reframe to state precisely what the results support.
So, conditional on the authors' promise to reframe this more precisely and consistently across the paper, posing it as a starting point not as a practical semantic speech decoding setup (and reporting W3 d and c results transparently in the paper), I will raise my score to 4.
We thank the reviewer for reconsidering our response and for the helpful guidance.
We agree that the semantic and intelligibility claims should be stated more precisely. In the final version, we will revise them consistently throughout the abstract, introduction, results, and conclusion. We will make clear that the current results do not demonstrate practical semantic speech decoding or reliably word-intelligible reconstruction. We will instead state only what is supported by the experiments: the EEG-derived representation shows trial-specific semantic correspondence, ESC shapes the representation during training, and semantic conditioning has a modest effect at inference.
We will also report the W3(c) and W3(d) results in full, including the small difference between matched and mismatched conditioning and the modest inference-time effect. We will present SENSE as an initial step toward semantic EEG-to-speech modeling, rather than as a practical semantic decoding system.
We appreciate the reviewer’s careful assessment and confirm that these revisions will be incorporated into the final version.
- Scope
- Minor or negligible ethical concerns (green)
Read ethics review
Ethics review
The submission uses a previously published public EEG benchmark and does not involve new human subject recruitment, data collection, or intervention by the authors. Based on the manuscript, I did not identify evidence of ethical concerns regarding participant recruitment, informed consent, or data acquisition. The work primarily proposes a new modeling framework evaluated on an established benchmark.
The primary ethical concern is the absence of an explicit Ethical Considerations section. Although the dataset is publicly available, EEG recordings constitute sensitive neurophysiological data, and research on brain-computer interfaces naturally raises broader discussions regarding neural data privacy, participant consent, and potential future misuse as decoding capabilities continue to improve.
I also note that another review raises concerns regarding human rights, particularly the potential for surveillance or broader deployment beyond controlled laboratory settings. While these concerns are valid as long-term considerations for the field, I do not believe they constitute a paper-specific ethical deficiency in the present submission. This work relies exclusively on a public benchmark, introduces no new human data collection, and does not propose new sensing hardware, deployment mechanisms, or capabilities that substantially expand practical surveillance risks. The proposed method is evaluated under a highly constrained passive-listening laboratory setting, and should not be interpreted as enabling unrestricted mind-reading or general-purpose thought decoding.
To improve the manuscript, I recommend adding a brief Ethical Considerations section in the camera-ready version. Such a discussion could explicitly clarify that:
- the study relies exclusively on a publicly released dataset collected under prior ethical approval;
- the proposed system is evaluated only in a controlled laboratory setting, and should not be interpreted as a general-purpose thought-decoding or unrestricted mind-reading system;
- future applications involving neural data should consider participant privacy, informed consent, secure handling of EEG recordings, and appropriate safeguards against potential misuse as brain decoding technologies continue to advance.
Overall, I consider these issues to be minor omissions in documentation rather than substantive ethical deficiencies. They are readily addressable through a short discussion of the broader ethical implications and limitations of the technology, without requiring changes to the technical content of the paper.
1 comment
We thank the reviewer for the positive assessment and helpful suggestions.
We agree that the manuscript would benefit from an explicit Ethical Considerations Section. In the camera-ready version, we will clarify that:
- the study relies exclusively on a previously released public EEG benchmark collected under prior ethical approval;
- no new participants, neural data collection, or sensing hardware are involved;
- the proposed system is evaluated only in a controlled passive-listening laboratory setting and should not be interpreted as enabling unrestricted thought decoding or general-purpose mind reading.
We will also discuss the importance of participant privacy, informed consent, secure handling of neural data, and appropriate safeguards for future applications as brain decoding technologies continue to advance.
We appreciate the reviewer's comments and will incorporate these clarifications in the revised manuscript.
- Scope
- Moderate ethical concerns (can likely be resolved) (yellow)
Read ethics review
Ethics review
Authors acknowledge that "potential negative impacts include privacy concerns about decoding mental content from brain signals"
At the same time, they state that "current EEG-to-speech systems require active listening to external stimuli and controlled lab settings, limiting misuse risk."
Apart from this, the authors don't suggest any mitigation strategy to address potential ethical risks.
The paper would benefit from a more robust approach to future mitigation if the technology leaves the lab and enters the real world. This can include short, tiered recommendations tied to technology readiness.
E.g.: Tier 1 - Consumer EEG headsets: on-device processing only, prohibition on use by third parties without approval, explicit opt-in consent for any semantic decoding functionality, etc. Tier - 2 - Clinical neuroprosthetics: IRB/ethics approval for deployment context, clear liability framework, etc.
The paper would also benefit from a mention of the 2025 UNESCO Recommendation on the Ethics of Neurotechnology, specifically, chapter III.2.3 (Protection of neural data as well as indirect neural data and non-neural data allowing mental states inferences).
1 comment
We thank the reviewer for the constructive suggestions. We agree that the manuscript should discuss future risk mitigation beyond the current laboratory setting. We will also revise our statement that active listening and controlled laboratory settings limit misuse risk, as these conditions should not be treated as reliable safeguards.
In the camera-ready version, we will add an Ethical Considerations clarifying that the proposed system is evaluated only under a controlled passive-listening laboratory setting using a previously released public EEG benchmark and should not be interpreted as enabling unrestricted thought decoding.
We will further include technology-readiness-based recommendations, such as:
- Consumer EEG devices: on-device processing by default, explicit opt-in consent for semantic decoding functionality, and restrictions on unauthorized third-party access.
- Clinical neuroprosthetic applications: deployment-specific ethical oversight, secure handling of neural recordings, and clear governance and accountability for neural-data use.
Following the reviewer’s suggestion, we will also reference the UNESCO Recommendation on the Ethics of Neurotechnology (2025), particularly its guidance on protecting neural data and other information that may enable inferences about mental states.
We appreciate this valuable suggestion and believe these additions will strengthen the discussion of responsible future deployment.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Rebuttal
We thank the reviewer for the positive assessment and for the suggestions on evaluation.
W1. Dataset size and overfitting
We agree that 7,200 training pairs are limited and cannot fully rule out dataset-specific overfitting.
The graph topology itself is not estimated from these pairs. It is fixed from the BioSemi electrode coordinates, while the graph encoder weights are learned during training. Our subject-scaling experiment also shows that held-out performance improves as the number of training subjects increases from 2 to 18. This suggests that SENSE continues to benefit from additional training data within the N400 dataset.
We agree that training the full model on a larger dataset would provide a stronger test of overfitting. Among the public datasets we examined, however, those providing paired EEG and natural speech audio at substantially larger scale were limited. We identified the Alice in Wonderland naturalistic listening dataset [1], which provides EEG together with the corresponding speech stimuli. It includes more participants than N400 dataset, but differs substantially in electrode configuration and data format.
We are currently examining whether it can be reliably adapted to the SENSE pipeline. We will continue this evaluation during the discussion period if the preprocessing and alignment can be validated.
In the meantime, we performed a complementary representation-level evaluation on a separate natural-speech dataset [2], reported below (W3).
W2. Absolute WER
We agree that WER close to 1 means that the reconstructed speech is not yet reliably word-intelligible. Our results show consistent improvement over existing EEG-to-speech baselines, but we do not claim practical speech decoding at the current performance level.
We also recomputed BERTScore with baseline rescaling to avoid over-interpreting the high raw scores. On the unseen-subject split, SENSE achieves 0.096, compared with 0.047 for FE-Phoneme and 0.018 for FESDE. This supports a relative improvement in semantic similarity over the baselines, but does not change the limitation indicated by WER.
W3. Natural-speech evaluation
We finetuned the N400-trained encoder and ESC projection on the Broderick naturalistic listened speech dataset [2], where participants listened to continuous narrative speech. We aligned each EEG segment with its corresponding text representation and compared the cosine similarity of matched EEG-text pairs with randomly mismatched pairs.
Matched EEG-text similarity was higher than similarity to randomly mismatched pairs for all 19 participants.
This experiment evaluates representation level EEG-text alignment rather than waveform reconstruction. It therefore does not replace full model training on a larger speech dataset. Still, it shows that the encoder and ESC objective can be adapted beyond the controlled N400 stimulus setting.
W4. Perceptual quality evaluation
We agree that listener-rated MOS would provide information that is not captured by the current metrics. A properly controlled listening study could not be completed during the rebuttal period. We therefore evaluated all 800 unseen-subject outputs using DNSMOS P.808 as an automatic estimate of perceptual speech quality.
SENSE has the highest estimated score among the generated outputs. We report this only as an automatic MOS estimate rather than a substitute for listener-rated evaluation.
W5. Training-budget fairness
We agree that comparing SENSE trained for 200k iterations with baselines trained for 100k could confound the model improvement with the longer training schedule. We therefore evaluated SENSE at the same 100k iteration budget as both baselines.
SENSE remains better than both baselines on all four metrics at the matched 100k budget. Continued training further improves SENSE:
Longer training further improves SENSE, but SENSE already outperforms both baselines at 100k iterations.
Reference
[1] Brennan et al., “EEG Datasets for Naturalistic Listening to ‘Alice in Wonderland’ (Version 2),” University of Michigan Deep Blue Data.
[2] Broderick et al., "Electrophysiological correlates of semantic dissimilarity reflect the comprehension of natural, narrative speech," Current Biology, 2018.