Probe-Guided Gradient Balancing for Multimodal Learning
Vu Vo Quoc, Haytham M. Fayek, Thuy T. Nguyen
NeurIPS 2026
TL;DR. PGGB decouples imbalance monitoring from the joint loss via stop-gradient probes, then boosts weaker modalities' gradients while composable with throttling methods
Abstract. Jointly trained multimodal networks frequently underutilize their weaker modalities, as faster-learning modalities dominate the shared fusion objective and suppress the gradient signal reaching slower ones. Most existing approaches throttle the dominant modality, whereas directly boosting the weaker modality often fails because monitoring signals derived from the joint loss are entangled with, and thus dominated by, the stronger modality. We propose a new gradient modulation approach, probe-guided gradient boosting (PGGB), to address the problem by probing and boosting the weak modalities while preserving the strength of the dominant modality. Probing is performed by attaching a lightweight linear classifier to each modality’s stop-gradient features to estimate the corresponding representation quality score. The unbiased gap between these scores across modalities, the utilization gap, serves as an imbalance signal that defines a bounded and smoothed scaling factor adaptively reweighing the gradients of weaker modalities, enabling stable and effective rebalancing during joint optimization. The method is composable with throttling methods as the intervention leaves the loss and fusion architecture unchanged. Extensive experiments were conducted across eight benchmarks spanning four domains and 2–4 modalities. The results show that our method outperforms state-of-the-art approaches on highly imbalanced multimodal datasets, while remaining competitive on benchmarks with low or no modality imbalance. Bounded scaling, self-attenuation, and a standard-SGD descent bound were established under standard smoothness and bounded-variance assumptions. Code is provided in the supplementary material.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:49 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
This paper proposes PGGB, a gradient-balancing method for multimodal learning. The method attaches stop-gradient linear probes to each modality, uses the probe-performance gap to identify underused modalities, and increases their encoder gradients through a bounded scaling rule. It can also be combined with methods such as OGM-GE that reduce the influence of the dominant modality.
The core idea is the strongest part of the paper. tQk1 considers the use of online probes as optimization controllers to be a novel and creative contribution. gN93 similarly finds the decoupled probe signal well motivated, lightweight, and easy to combine with existing training methods. The experiments cover several domains and include ablations and representation-level analysis. The clearest positive result is on CREMA-D, where the method improves the weaker modality while largely preserving the stronger one.
The empirical picture is less convincing across the full benchmark suite. miLe notes that the improvement over the strongest baseline is below 0.5 percentage points on seven of eight datasets. The same reviewer observes that OGM-GE accounts for most of the gain in the main ablation, while the additional PGGB improvement is within the reported seed variation. There is also an important unresolved discrepancy between the OGM-GE result reported on CREMA-D and the result in the original OGM-GE paper.
A second concern is the interaction with the optimizer. miLe argues that direct gradient scaling may have little effect under Adam, which is used on half of the datasets, and that these datasets indeed show only small gains. This needs a precise explanation or an analysis of the actual parameter updates.
The theoretical results are useful as basic safety properties, but they do not show that PGGB closes the modality gap or improves convergence speed, as pointed out by tQk1. gN93 also asks whether the stated guarantees meaningfully cover the high-imbalance regime that motivates the method. The paper should therefore state the scope of these results more carefully.
The most important points for the rebuttal are, in my opinion, as follows:
- explain the CREMA-D baseline discrepancy raised by miLe;
- clarify whether and how PGGB changes effective updates under Adam;
- isolate the contribution of PGGB from OGM-GE with uncertainty over their difference;
- provide early probe trajectories, including any warm-up behavior, as requested by tQk1;
- clarify the dataset-level imbalance score and the choice of the 0.15 threshold, as requested by gN93; and
- revise the theoretical claims so they match what the propositions establish.
To conclude, I lean toward acceptance because the probe-guided monitoring idea is original, simple, and suitable for a Concept and Feasibility contribution. However, the empirical attribution and the CREMA-D comparison need to be resolved in the response.
Final justification
I have read the rebuttal and the discussion that followed. Overall, the response addressed the main points that made me hesitant in the initial meta-review, so my confidence in the acceptance recommendation is now higher.
The part I find most convincing is still the basic idea of using stop-gradient probes to monitor the modalities during training and then using this signal to adjust the optimization. This is simple, easy to interpret, and different from approaches that only suppress the dominant modality.
The rebuttal helped on several important points:
- The confusion around the CREMA-D comparison was cleared up and traced to different experimental protocols.
- The additional ablations make it easier to see what PGGB itself contributes beyond OGM-GE.
- The authors directly tested the optimizer issue and showed that the method is much more effective with SGD than with Adam. This is a real limitation, but it is now clearly understood rather than left unexplained.
- The probe trajectories suggest that the dominant modality is identified early enough for the method to be useful in practice.
- The imbalance score and its threshold are now explained more clearly.
- The theory is now presented more modestly and accurately as providing safety properties, rather than proving that the method necessarily closes the modality gap or speeds up convergence.
The reviewer discussion also moved in a positive direction. One reviewer remained clearly supportive, another felt that most of the concerns were addressed under the Concept and Feasibility criteria, and the initially negative reviewer raised the score after the rebuttal, although they still pointed out the limited gains on several datasets and the dependence on the optimizer.
I agree that these limitations should remain visible in the final paper. The method does not help equally across all datasets, and its usefulness under Adam appears limited. Still, for a Concept and Feasibility submission, I think the probe-guided optimization idea is interesting enough and sufficiently supported by the experiments.
For these reasons, I recommend Accept (poster), with higher confidence than in my initial recommendation.
Read meta-review
Meta-review
This paper proposes PGGB, a gradient-balancing method for multimodal learning. The method attaches stop-gradient linear probes to each modality, uses the probe-performance gap to identify underused modalities, and increases their encoder gradients through a bounded scaling rule. It can also be combined with methods such as OGM-GE that reduce the influence of the dominant modality.
The core idea is the strongest part of the paper. tQk1 considers the use of online probes as optimization controllers to be a novel and creative contribution. gN93 similarly finds the decoupled probe signal well motivated, lightweight, and easy to combine with existing training methods. The experiments cover several domains and include ablations and representation-level analysis. The clearest positive result is on CREMA-D, where the method improves the weaker modality while largely preserving the stronger one.
The empirical picture is less convincing across the full benchmark suite. miLe notes that the improvement over the strongest baseline is below 0.5 percentage points on seven of eight datasets. The same reviewer observes that OGM-GE accounts for most of the gain in the main ablation, while the additional PGGB improvement is within the reported seed variation. There is also an important unresolved discrepancy between the OGM-GE result reported on CREMA-D and the result in the original OGM-GE paper.
A second concern is the interaction with the optimizer. miLe argues that direct gradient scaling may have little effect under Adam, which is used on half of the datasets, and that these datasets indeed show only small gains. This needs a precise explanation or an analysis of the actual parameter updates.
The theoretical results are useful as basic safety properties, but they do not show that PGGB closes the modality gap or improves convergence speed, as pointed out by tQk1. gN93 also asks whether the stated guarantees meaningfully cover the high-imbalance regime that motivates the method. The paper should therefore state the scope of these results more carefully.
The most important points for the rebuttal are, in my opinion, as follows:
- explain the CREMA-D baseline discrepancy raised by miLe;
- clarify whether and how PGGB changes effective updates under Adam;
- isolate the contribution of PGGB from OGM-GE with uncertainty over their difference;
- provide early probe trajectories, including any warm-up behavior, as requested by tQk1;
- clarify the dataset-level imbalance score and the choice of the 0.15 threshold, as requested by gN93; and
- revise the theoretical claims so they match what the propositions establish.
To conclude, I lean toward acceptance because the probe-guided monitoring idea is original, simple, and suitable for a Concept and Feasibility contribution. However, the empirical attribution and the CREMA-D comparison need to be resolved in the response.
Final justification
I have read the rebuttal and the discussion that followed. Overall, the response addressed the main points that made me hesitant in the initial meta-review, so my confidence in the acceptance recommendation is now higher.
The part I find most convincing is still the basic idea of using stop-gradient probes to monitor the modalities during training and then using this signal to adjust the optimization. This is simple, easy to interpret, and different from approaches that only suppress the dominant modality.
The rebuttal helped on several important points:
- The confusion around the CREMA-D comparison was cleared up and traced to different experimental protocols.
- The additional ablations make it easier to see what PGGB itself contributes beyond OGM-GE.
- The authors directly tested the optimizer issue and showed that the method is much more effective with SGD than with Adam. This is a real limitation, but it is now clearly understood rather than left unexplained.
- The probe trajectories suggest that the dominant modality is identified early enough for the method to be useful in practice.
- The imbalance score and its threshold are now explained more clearly.
- The theory is now presented more modestly and accurately as providing safety properties, rather than proving that the method necessarily closes the modality gap or speeds up convergence.
The reviewer discussion also moved in a positive direction. One reviewer remained clearly supportive, another felt that most of the concerns were addressed under the Concept and Feasibility criteria, and the initially negative reviewer raised the score after the rebuttal, although they still pointed out the limited gains on several datasets and the dependence on the optimizer.
I agree that these limitations should remain visible in the final paper. The method does not help equally across all datasets, and its usefulness under Adam appears limited. Still, for a Concept and Feasibility submission, I think the probe-guided optimization idea is interesting enough and sufficiently supported by the experiments.
For these reasons, I recommend Accept (poster), with higher confidence than in my initial recommendation.
1 comment
- Rating
- 3/6
- Confidence
- 4/5
- Quality
- 2/4
- Clarity
- 2/4
- Significance
- 2/4
- Originality
- 3/4
- Contribution type
- concept_feasibility
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The learning dynamics of late-fusion multi-modal architectures favor expedited learning of one modality at the expense of another when it provides stronger or easier-to-learn signal. This paper proposes a method, probe-guided gradient boosting (PGGB), to address this problem. PGGB boosts the gradients to the weaker modality's encoder by scaling it by a factor > 1. Prior work (OGM-GE) has proposed throttling the stronger modality's encoder by scaling it with a factor < 1. On the other hand, prior works proposing to boost the gradient have done so in ways that are still biased toward the stronger modality. PGGB uses linear probes on the modality encoders to estimate the "utilization gap" between the prediction accuracies of the strong and the weak modalities and computes the boosting scale based on that. By using a stop-gradient operator before the linear probe, PGGB decouples the monitoring signal from modality-biased learning dynamics. PGGB can also be combined with OGM-GE. The paper shows empirical results on a number of datasets, gives theoretical guarantees for PGGB and performs various ablation studies.
Strengths and weaknesses
Strengths
S1. The method PGGB is simple and reasonable (albeit not for scale-invariant optimizers like Adam, see Weaknesses).
S2. The experiments cover many datasets from different domains.
S3. There are many ablations.
S4. The paper provides theoretical guarantees for PGGB.
Weaknesses
W1. Firstly, I believe this paper would be better served by contribution type "General" instead of "Concept and Feasibility" as the scope of the proposed method is small enough to be validated in a single paper.
W2. My biggest concern is that the results are underwhelming. The main results table (Table 1) shows improvements of < 0.5 pp over the best baseline on 7 out of 8 datasets which is extremely minor.
W3. The proposed method of scaling the gradients should not be expected to give significant gains for the Adam optimizer which is scale-invariant / unit-less. 4 out of 8 datasets use Adam and as expected show barely any improvement. OGM-GE has plausible improvement even with Adam (see Table 6 in their paper) because the GE component goes beyond mere gradient scaling.
W4. The ablation table (Table 2) shows that OGM-GE alone recovers most of the gap between PGGB+OGM-GE and the baseline (2.17pp) and PGGB's contribution is minor (0.22pp) well within the per-seed standard deviation.
Questions
Q1. On L17 what are the 2-4 modalities?
Q2. L131, g is undefined.
Q3. The last paragraph of section 3.1 is quite unclear about the intuition and formalism of what is being said.
Q4. L147 is unclear.
Q5. On L172, s_m becomes undefined when modalities are balanced, not what is said in the paper.
Q6. For section 3.5, what are the intuitions and takeaways from the propositions?
Q7. MAJOR. The OGM-GE paper reports 61.59 on CREMA-D. You report 69.14. Where is this discrepancy coming from?
Limitations
Yes.
Final justification
(copied from the rebuttal comment)
I thank the authors for the rebuttal.
The new experiments are in the right direction, showing (slightly) better margins against baselines (W2), clarifying the dependence on optimizer (PGGB does not help Adam) (W3), and achieving (slightly) superior contribution to the OGM-GE+PGGB combination (W4).
However, even taking these new results into account, my concerns of empirical significance remain:
- The margins against baselines are still small and limited to a few regimes, each with minimal supporting evidence. In fact, large benefit is conclusively demonstrated (beyond noise margin) only for 1 dataset (CREMA-D) out of 8 datasets, under its default training setup. For future revisions, I encourage the authors to select a set of evaluation datasets which can adequately demonstrate the superiority of the method with good support.
- My original concern regarding optimizer sensitivity is reinforced by the new experiments. PGGB is indeed shown to be empirically beneficial only for SGD and not for Adam. This limits the applicability of the paper as SGD remains the optimizer of choice in only limited applications, and further 50% of the datasets used are those where Adam is the preferred optimizer.
That said, I am raising my score, and overall encourage the authors to improve the evaluation settings (such as 1-frame vs 3-frame), dataset selection and result framing (e.g. OGM-GE and OGM-GE+PGGB results and ablations) in future versions.
Formatting concerns
None.
4 comments
Rebuttal
Thank you for your constructive and technically sharp review. Supporting results are from the submitted paper unless tagged [NEW] (run in this window, for the revision).
[Q7, MAJOR] The OGM-GE paper reports 61.59 on CREMA-D. You report 69.14. Where is this discrepancy coming from?
Response. OGM-GE (Peng et al., CVPR 2022) reports 61.9% on CREMA-D (their Tables 1 and 2, concatenation fusion). The 61.59 figure is the joint-training baseline row of our own Table 1. The adjacency of these rows invites the reading, and we will relabel them. Their protocol uses one visual frame per clip (their Section 4.2). Two facts resolve the comparison:
- We reproduce their result at their operating point. Our 1-frame ablation (Table 2) yields OGM-GE at , and their published 61.9 lies within one seed std of our mean.
- Our main table uses 3 frames at 3 fps, a matched pipeline shared by all methods in Table 1. The richer input raises OGM-GE by +6.7 pp over its 1-frame result. We will correct Section 4.1's protocol attribution ("following OGM-GE").
The revised Table 1 note is presented as follows.
Baseline denotes joint training with unmodified gradients (not a published OGM-GE result). All methods are re-run under the matched 3-frame protocol of Section 4.1. Their 1-frame result (61.9) is reproduced at in Table 2.
[W1] This paper would be better served by contribution type "General" instead of "Concept and Feasibility", as the scope of the proposed method is small enough to be validated in a single paper.
Response. We appreciate the perspective. We selected "Concept and Feasibility" because probe-guided control opens scope beyond what this paper validates, but we are happy to accept "General" and defer to the AC's judgment.
[W2] The main results table shows improvements of < 0.5 pp over the best baseline on 7 out of 8 datasets, which is extremely minor.
Response. Seven of eight margins are of that order. Table 1's best-versus-best presentation, however, understates what the comparison shows.
For perspective, on the low-imbalance benchmarks competing methods regress rather than gain (OGM-GE: KS -1.80 pp, Twitter15 -0.27, Sarcasm -0.59), while standalone PGGB is best on all four, at +1.61% measured overhead with 3K-parameter probes [NEW], a favorable efficiency trade-off.
On the one benchmark with severe imbalance and trainable encoders, the margin is larger, and we confirmed its robustness: [NEW] we extended the comparison to per arm, fixing the final five seeds in advance under a stopping rule (all 15 reported, no further additions). PGGB+OGM-GE gives versus for the arm: +1.60 pp, 95% Welch CI [0.59, 2.62], Welch , Mann-Whitney , . The arm matches standalone OGM-GE within seed noise (69.14, Table 1), so this is also the margin over the best baseline. We state the trajectory plainly: +2.31 (original 5), +2.06 (), +1.60 (): the original seeds were favorable draws and the pooled estimate is smaller than first reported; the two later batches are not individually significant, and the pooled CI excludes zero. The updated version adopts the statistics as the headline, with all 30 per-seed values in the appendix.
In summary:
| Regime | Outcome |
|---|---|
| Severe imbalance, trainable encoders (CREMA-D) | +1.60 pp over the arm at (final 5 seeds pre-registered), CI [0.59, 2.62], |
| Low imbalance (AVE, KS, Twitter15, Sarcasm) | PGGB best method on all four (margins within seed noise); OGM-GE regresses on three |
| High imbalance under Adam (sentiment) | Effect within seed std; attenuation measured, and reversed under SGD (+1.69 pp, W3) |
| Dense prediction (BraTS 2021) | Reported separately as segmentation (Section 4.1) |
[W3] The proposed method of scaling the gradients should not be expected to give significant gains for the Adam optimizer, which is scale-invariant / unit-less. 4 out of 8 datasets use Adam and as expected show barely any improvement. OGM-GE has plausible improvement even with Adam because the GE component goes beyond mere gradient scaling.
Response. We measured the mechanism you describe directly. [NEW] Additional per-step instrumentation records the applied scale, post-scaling gradient norm, and actual update norm per encoder ( versus , matched seeds; each row reports that run's most-boosted modality, with the full per-modality table to follow in the appendix):
| Pipeline (optimizer) | boost scale | grad-norm ratio | update-norm ratio |
|---|---|---|---|
| CREMA-D (SGD), most-boosted modality | 1.64 | 1.52 | 1.50 |
| CMU-MOSI (Adam), most-boosted modality | 1.48 | 1.38 | 1.17 |
| CMU-MOSI (SGD control), most-boosted modality | 1.45 | 1.53 | 1.47 |
The table confirms your prediction: under SGD the applied boost reaches the parameter updates (1.50 update ratio at 1.64 applied), under Adam second-moment normalization absorbs roughly two-thirds of it (1.17 at 1.48), and switching the identical MOSI pipeline to SGD restores transmission (1.47 at 1.45). [NEW] To test the accuracy consequence, we ran the same composed contrast at full budget under both optimizers, 5 matched seeds.
| MOSI (, composed) | Boost effect | ||
|---|---|---|---|
| Adam | pp () | ||
| SGD (control) | +1.69 pp (, 5/5 seeds) |
SGD is not retuned for this pipeline (hence its lower absolute accuracy), so the contrast is within-optimizer only. This changes no reported number; it scopes the mechanism: all headline effects arise on SGD pipelines, and OGM-GE's Adam results similarly rely on its GE noise term rather than pure scaling, as you observe. We will state the optimizer dependence in Sections 3.3 and 5, add both tables to the appendix, and list optimizer-state-aware actuation as future work.
[W4] The ablation table (Table 2) shows that OGM-GE alone recovers most of the gap between PGGB+OGM-GE and the baseline (2.17 pp) and PGGB's contribution is minor (0.22 pp), well within the per-seed standard deviation.
Response.
- The 0.22 pp figure comes from the 1-frame ablation, where the visual modality is information-starved: boosting amplifies the weak encoder's gradient signal but cannot create information the input does not carry. Throttling, which acts on the information-rich dominant modality, is amplified at 1-frame, while boosting is starved there.
- Under the main 3-frame protocol the same decomposition gives +1.60 pp at (CI excluding zero, see W2), versus 0.22 pp (within noise) at 1-frame, isolating boost actuation within the OGM-GE composition: the arm holds the entire probe pipeline active and differs only in the multiplicative scale. We do not claim this increment generalizes across throttlers (App. B.7 marks non-OGM-GE compositions within noise).
- We agree the isolating decomposition should live at the main operating point: in the updated version, we will promote the 3-frame decomposition (with the statistics) to the primary ablation table and retain the 1-frame variant as the information-availability ablation.
[Q1-Q6] Clarity questions.
Response. We appreciate the reviewer's careful reading and constructive feedback, which helped us identify several minor technical details requiring clarification. Each is addressed below.
- Q1 (L17): The 2-4 modalities are: 2 for audio+visual (CREMA-D, AVE, KS) and text+image (Twitter15, Sarcasm), 3 for text+audio+vision (CMU-MOSI and CMU-MOSEI), 4 for four MRI sequences (BraTS 2021). We will enumerate this in Section 4.1.
- Q2 (L131, undefined): Thank you for pointing out this subtle omission: the fusion classifier is used before being formally defined. We will add the definition after Eq. 1.
- Q3 (last paragraph of 3.1): we will rewrite it as: "Each encoder's fusion-loss gradient passes through the fusion head's per-modality weighting , which a dominant modality shapes. Imbalance signals computed from therefore measure the weak modality through a term the dominant modality has already biased."
- Q4 (L147-148): the sentence could be a bit clearer. The full replacement sentence (closing the probe paragraph of Section 3.2): "This is precisely why decoupling matters: the probe accuracy reflects the representation quality of alone, independent of how the fusion head weights modality ."
- Q5 (L172, at balance): is in fact well-defined at exact balance: when all are equal, the numerator of Eq. 7 is zero for every while the denominator equals , so and exactly (no intervention). We will add one sentence to the manuscript for clarifying this.
- Q6 (takeaways of Section 3.5): the intended takeaway for Propositions 1-3 are safety properties of the training run(bounded intervention, neutrality at exact balance, standard SGD descent preserved), so adding PGGB cannot destabilize the training it composes with.
Thank you again for your thoughtful review, which led to the addition of optimizer controls and seed analysis. We appreciate your feedback and would be grateful if you would reconsider your rating in light of these revisions.
A Gentle Follow-up
Dear Reviewer miLe,
Thank you again for the time and care you put into reviewing our paper. We would like to kindly follow up on our previous response, and we hope our responses have addressed the main concerns regarding the CREMA-D comparison, the effect of Adam, and PGGB’s contribution beyond OGM-GE.
Please let us know if any concerns remain. We would be very happy to provide further clarification while the discussion period remains open, and we are committed to incorporating these analyses and revisions into the final manuscript. Thank you once again for your valuable time.
I thank the authors for the rebuttal.
The new experiments are in the right direction, showing (slightly) better margins against baselines (W2), clarifying the dependence on optimizer (PGGB does not help Adam) (W3), and achieving (slightly) superior contribution to the OGM-GE+PGGB combination (W4).
However, even taking these new results into account, my concerns of empirical significance remain:
-
The margins against baselines are still small and limited to a few regimes, each with minimal supporting evidence. In fact, large benefit is conclusively demonstrated (beyond noise margin) only for 1 dataset (CREMA-D) out of 8 datasets, under its default training setup. For future revisions, I encourage the authors to select a set of evaluation datasets which can adequately demonstrate the superiority of the method with good support.
-
My original concern regarding optimizer sensitivity is reinforced by the new experiments. PGGB is indeed shown to be empirically beneficial only for SGD and not for Adam. This limits the applicability of the paper as SGD remains the optimizer of choice in only limited applications, and further 50% of the datasets used are those where Adam is the preferred optimizer.
That said, I am raising my score, and overall encourage the authors to improve the evaluation settings (such as 1-frame vs 3-frame), dataset selection and result framing (e.g. OGM-GE and OGM-GE+PGGB results and ablations) in future versions.
Dear Reviewer miLe,
Thank you for reconsidering our rebuttal and raising your score. We greatly appreciate your feedback and will carefully incorporate it into the revised version of the paper.
- Rating
- 5/6
- Confidence
- 3/5
- Quality
- 4/4
- Clarity
- 4/4
- Significance
- 4/4
- Originality
- 4/4
- Contribution type
- concept_feasibility
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper addresses the modality imbalance problem in multimodal machine learning, where jointly trained networks underutilize weaker modalities because a dominant, faster-learning modality controls the shared objective and suppresses the gradient signals of slower ones. To solve this, the authors introduce decoupled probe monitoring, which attaches lightweight linear classifiers to the stop-gradient features of each modality encoder.
Strengths and weaknesses
Strengths: The paper presents a novel optimization framework addressing the well-documented phenomenon of modality imbalance in multimodal learning. While linear probes are widely used as diagnostic tools in representation learning, repurposing them as real-time, online, stop-gradient meta-controllers during optimization is an innovative and highly creative algorithmic concept. Weaknesses:
- Could the authors provide a detailed wall-clock time and memory consumption for PGGB against baseline training?
- Could the authors provide early-training probe trajectory plots showing whether the utilization gap correctly identifies the dominant modality from the start, and if any early misdirection occurs? Or is there any warm-up period?
- The paper presents three propositions as theoretical contributions. I understand that the authors mentioned that "A rate-level analysis tying gap closure to probe dynamics is left for future work". Given that the paper claims theoretical contributions in the abstract and introduction, it would be great if the authors could clarify how these propositions help prove whether PGGB actually closes the modality gap or improves convergence speed. Or the abstract and introduction could be reworded to more precisely characterize the theoretical results.
Questions
Please refer to the weaknesses.
Limitations
Yes.
Formatting concerns
No major violations of formatting rules.
3 comments
Rebuttal
Thank you very much for the positive assessment and for recognizing the repurposing of linear probes as real-time, stop-gradient meta-controllers as a novel algorithmic concept. All three requested items are addressed below; all supporting results are from the submitted paper unless tagged [NEW] (run during this discussion period, to be included in the revision).
[W1] Could the authors provide a detailed wall-clock time and memory consumption for PGGB against baseline training?
Response. Thank you for this practical question. [NEW] Measured on one RTX 4090, CREMA-D 3-frame, mean seconds/epoch over 7 epochs, identical data pipeline:
| Configuration | s/epoch | overhead | peak GPU memory |
|---|---|---|---|
| Baseline (joint training) | 17.43 | reference | ~12.2 GB |
| PGGB (probes + boost) | 17.71 | +1.61% | ~12.2 GB |
| PGGB+OGM-GE | 18.71 | +7.34% | ~12.2 GB |
- The probe-attributable overhead is +1.61%, slightly above the ~1% estimate in Section 4.1, which we will update to the measured figure. The remaining ~5.7 pp in the composed row is OGM-GE's own per-modality contribution computation, incurred by OGM-GE with or without PGGB.
- Peak memory is unchanged across the three configurations (12.1-12.3 GB): each probe is a single linear layer (~3K parameters, or ~0.03% of one ResNet-18 encoder), and the EMA state is two scalars per modality (the smoothed probe accuracy and the smoothed boost scale ), i.e., four scalars in total here.
- We will add this table to the appendix.
[W2] Could the authors provide early-training probe trajectory plots showing whether the utilization gap correctly identifies the dominant modality from the start, and if any early misdirection occurs? Or is there any warm-up period?
Response. Thank you for this suggestion. [NEW] We instrumented all 500 probe evaluations of a full CREMA-D training run (every iterations within each 105-iteration epoch, given by the 6,698 training samples at batch size 64, so 5 events per epoch over 100 epochs) and examined the early window. Since plots cannot be attached, we tabulate the EMA-smoothed probe accuracies (%) at the early probe events, and will add the corresponding figure to the appendix:
| Probe event | Iteration (epoch) | Gap (pp) | ||
|---|---|---|---|---|
| 1st | 19 (ep. 1) | 2.1 | 2.8 | -0.7 |
| 2nd | 39 (ep. 1) | 6.4 | 5.3 | +1.2 |
| 3rd | 59 (ep. 1) | 9.2 | 7.5 | +1.7 |
| 4th | 79 (ep. 1) | 11.7 | 9.4 | +2.3 |
| 5th | 99 (ep. 1) | 17.1 | 10.8 | +6.3 |
| end of epoch 2 | 204 | 25.9 | 16.1 | +9.8 |
| end of epoch 3 | 309 | 29.3 | 16.5 | +12.8 |
- At the first probe event (iteration 19), both probes are statistically at chance: the raw accuracies on the 32-sample evaluation half are 9.4% (3/32) and 15.6% (5/32), both within two binomial standard deviations ( pp at ) of the 16.67% chance level for 6 classes. The inverted smoothed ordering (-0.7 pp) therefore carries no signal at this event. (The tabulated values are small because the probe-accuracy EMA is still ramping from its zero initialization.)
- From the second probe event (iteration 39) onward, the utilization gap correctly identifies audio as dominant (+1.2 pp, growing to +12.8 pp by the end of epoch 3), and no further inversion is observed through epoch 50.
- The only two later inversions (2 of the 500 probe events, both after epoch 50) occur exactly where the smoothed gap passes through zero (-0.3 and -1.3 pp). At a near-zero gap, the sign of the ordering reflects estimator noise rather than a change in dominance, so these events convey no misdirection. No inversion persisted beyond a single probe event in the instrumented run.
- Exposure to a single misdirected window is small as a direct consequence of the update rule: scales initialize at 1 and are refreshed only at probe events, so a misdirected first window carries a smoothed scale of at most (, in this composed run), against the global cap of Prop. 1.
- No explicit warm-up period is used, and none is needed: scales initialize at the neutral , the first probe event lands at iteration 19 of 10,500, and single-event exposure is bounded as in point 4.
[W3] Given that the paper claims theoretical contributions in the abstract and introduction, could the authors clarify how the propositions help prove whether PGGB actually closes the modality gap or improves convergence speed? Or the abstract and introduction could be reworded to more precisely characterize the theoretical results.
Response. Thank you for the valuable comment regarding the theoretical contributions. We agree with your reading and will reword the corresponding sections accordingly.
- The three propositions are safety properties: the intervention is bounded (Prop. 1), provably small near exact balance (Prop. 2), and training under the intervention retains the standard nonconvex SGD descent guarantee with a quantified worst-case variance inflation of (Prop. 3).
- They do not establish that PGGB closes the modality gap or improves convergence speed. Gap closure is supported empirically (Section 4.4: the weak-modality probe rises +9.41 pp while the strong falls only 0.81 pp, and the post-hoc utilization gap shrinks versus baseline).
- We will reword the abstract, the introduction, and the corresponding statements in Sections 3.3 and 4.2 in the updated version to characterize the results precisely as safety guarantees. The revised sentence is presented as follows.
We establish three safety properties: bounded scaling, self-attenuation, and a standard-SGD descent bound with quantified variance inflation. A rate-level analysis linking gap closure to probe dynamics remains open.
Thank you again for a review focused on exactly the feasibility questions this contribution needed answered.
The answers have addressed my concerns. Thank you.
Dear Reviewer tQk1,
Thank you for confirming that our responses addressed your concerns. We greatly appreciate your thoughtful review, your valuable comments, and your positive view of our work.
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- concept_feasibility
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper proposes Probe-Guided Gradient Boosting (PGGB) for multimodal learning, targeting the problem where one dominant modality can suppress learning in weaker modalities during joint optimization. The key idea is to attach lightweight linear probes to stop-gradient modality features, use probe accuracy gaps as a decoupled signal of modality imbalance, and boost gradients for weaker modalities using a bounded and smoothed scaling factor. The method can also be combined with existing dominant-modality throttling methods such as OGM-GE. The paper evaluates the approach across audio-visual, sentiment, text-image, and medical segmentation benchmarks, showing strong gains on CREMA-D and competitive or modest gains on other datasets.
Strengths and weaknesses
Strengths
The use of stop-gradient probes as online controllers for multimodal optimization is a novel and promising concept. This framework may have broader potential beyond the specific gradient-boosting mechanism and benchmarks evaluated in this paper.
The paper addresses an important and practical problem in multimodal learning: jointly trained models can over-rely on a dominant modality and underuse weaker but potentially useful modalities. The proposed PGGB method is novel because it uses stop-gradient linear probes to estimate modality utilization separately from the coupled joint loss. This gives a cleaner signal for identifying weaker modalities than methods that rely directly on the shared fusion objective.
The method is also lightweight and easy to combine with existing gradient modulation approaches. It does not require changing the fusion architecture or the main training loss, and the additional probe overhead is small. The experimental evaluation is reasonably broad, covering audio-visual, sentiment, text-image, and medical segmentation benchmarks. The results are strong on CREMA-D, where PGGB combined with OGM-GE improves over both standard joint training and OGM-GE alone. The ablation and post-hoc probe analyses also help support the claim that the method improves weak-modality representation quality while mostly preserving the stronger modality.
Weaknesses
-
The safety discussion in Section 3.5 is somewhat incomplete. The paper states that the safety properties show the method does not diverge or harm low-imbalance training, but it is less clear what happens in high-imbalance settings, which are the main target of the method. Since the strongest claimed benefit is on high-imbalance data, the authors should explain whether the bounded scaling and descent bound provide meaningful stability guarantees there, or whether high-imbalance behavior is supported mainly by empirical evidence.
-
The imbalance categorization in Section 4.1 needs clearer explanation in the main text. The paper categorizes datasets as high-imbalance when (delta > 0.15), but it is not immediately clear how one final (delta) value is obtained for a whole dataset. Appendix B.9 indicates that this is based on final-epoch EMA-smoothed probe accuracy gaps averaged over five seeds, but this should be stated explicitly in the main text. The authors should also justify the threshold (0.15) and discuss whether the categorization is sensitive to training epoch, probe quality, seed variation, or the chosen baseline.
-
The high-imbalance text-dominant sentiment datasets, CMU-MOSI and CMU-MOSEI, deserve deeper analysis. The authors state that text alone is near-multimodally sufficient and therefore only modest gains are expected, but this makes these datasets important extreme cases for testing the method. It would be useful to include more unimodal analysis showing whether PGGB actually improves the weaker audio and visual representations, even if final multimodal accuracy changes little.
-
Relatedly, it is unclear whether the limited gains on CMU-MOSI and CMU-MOSEI come from optimization imbalance or from intrinsic modality characteristics. Text, audio, and visual modalities may differ in task relevance more fundamentally than, for example, audio and visual modalities in CREMA-D. The authors should discuss whether boosting the weaker modalities is expected to help in such text-dominant settings, and whether increasing the boost strength (alpha) could improve learning from audio/visual modalities or instead amplify noisy, less informative signals.
Questions
-
In Section 3.5, the safety properties are described as ensuring that the method does not harm low-imbalance training. What should we expect in high-imbalance settings? Are there any stability guarantees or diagnostic criteria for when boosting may become harmful?
-
How exactly is the dataset-level (delta) value computed for imbalance categorization? Is it the final-epoch EMA-smoothed gap averaged over seeds, or some statistic over the full training trajectory? Please clarify this in the main text and justify the threshold (delta > 0.15).
-
For CMU-MOSI and CMU-MOSEI, can the authors provide a deeper unimodal analysis showing whether PGGB improves the audio and visual representations even when final multimodal accuracy changes little?
-
On text-dominant sentiment tasks, would increasing (alpha) help the model learn more from weaker audio/visual modalities, or does it degrade performance because those modalities are intrinsically less informative? An (alpha)-sensitivity study on CMU MOSI/MOSEI would be useful.
Limitations
No. The authors discuss some limitations, including per-setting tuning, probe overhead, and possible regressions when composing with throttling. However, the limitations section should more directly address high-imbalance safety, sensitivity of the imbalance categorization, and the possibility that some weak modalities may be intrinsically less task-informative rather than merely undertrained.
Final justification
I reassessed the paper under the Concept and Feasibility criteria. The use of stop-gradient probes as online optimization controllers is a novel and promising idea, and the rebuttal adequately addressed most of my concerns. Although limitations remain regarding optimizer dependence, limited statistically significant gains beyond CREMA-D, and distinguishing undertrained from intrinsically less informative modalities, the paper provides sufficient initial evidence for this contribution type. I therefore maintain my borderline-accept score.
Formatting concerns
No major formatting concerns observed.
2 comments
Rebuttal
Thank you for the careful and constructive review, and for recognizing PGGB as novel, lightweight, and easy to combine with existing gradient modulation approaches. The four concerns are thoughtful. Below are our responses to each question; all supporting results are already in the submitted paper unless tagged [NEW] (run during this discussion period, to be included in the revision).
[W1, Q1] In Section 3.5, the safety properties are described as ensuring that the method does not harm low-imbalance training. What should we expect in high-imbalance settings? Are there any stability guarantees or diagnostic criteria for when boosting may become harmful?
Response. The propositions cover low-imbalance and high-imbalance regimes, in the following division of labor.
- The descent bound (Prop. 3) is uniform in the imbalance level: it holds for any utilization gap, for step sizes satisfying its condition (). What limits it is the optimizer, not the imbalance: the proof assumes SGD (Section 3.5). Among the high-imbalance benchmarks such as CREMA-D, where the guarantee is that PGGB preserves standard descent with gradient variance inflated by at most . CMU-MOSI and CMU-MOSEI are trained with Adam (Section 4.1) and therefore fall outside Prop. 3, so our claims there rest on the measured results alone.
- Prop. 2 is the complementary guarantee at the balanced end: it bounds the intervention as , a bound that tightens as the utilization gap shrinks and gives exactly (no intervention) at exact balance.
- On diagnostic criteria: our operating-conditions analysis (Section 4.3.1) identifies the failure regime observed in practice, a thin data budget combined with weak inherent asymmetry, where the failure localizes to the throttling component rather than the boost. The monitored quantities, the utilization gap and the smoothed per-modality boost scale , can be logged during training as an early caution (a small dominance gap is a signal not to compose with throttling), though an automated criterion remains future work.
- We will state this scoping explicitly in Section 3.5 and expand the Limitations accordingly (see our response to your [Limitations] comment).
[W2, Q2] How exactly is the dataset-level delta value computed for imbalance categorization? Is it the final-epoch EMA-smoothed gap averaged over seeds, or some statistic over the full training trajectory? Please clarify this in the main text and justify the threshold (delta > 0.15).
Response. We answer the computation and the threshold in turn.
- Explanation. is the final-epoch EMA-smoothed probe-accuracy gap measured during baseline training (no intervention), averaged over 5 seeds (Appendix B.9). It is not a statistic over the full trajectory. It covers the seven classification benchmarks; BraTS 2021 is a dense-prediction segmentation benchmark reported separately (Section 4.1). We will add this explanation to Section 4.1 in the updated version.
- Why 0.15. The threshold is not tuned. Sorting the seven measured values gives AVE 0.017, KS 0.038, Sarcasm 0.076, Twitter15 0.150, then CMU-MOSEI 0.178, CMU-MOSI 0.222, CREMA-D 0.268: no benchmark falls between 0.150 and 0.178. We placed the threshold in that empty band and rounded it to 0.15. Two properties follow. (a) Robustness to the choice: since a benchmark is categorized as high-imbalance when exceeds the threshold, every threshold in produces the identical categorization, so no result in the paper depends on the specific value 0.15. (b) Independence from results: is measured on baseline training alone, before any method is applied, so the categorization cannot have been adjusted to favor any method.
- Boundary cases. Appendix B.9 already reports the per-dataset means and seed standard deviations, which show that the two datasets whose measured lies closest to the 0.15 threshold also carry the largest seed variances: Twitter15 () and CMU-MOSEI (). In the updated version we will flag both explicitly as boundary cases.
- Sensitivity. The per-seed spread is already reported in Appendix B.9, and is measured on the paper's standard no-intervention configuration (Section 4.1), so it inherits that recipe's architecture and optimizer choices. In the updated version we will extend the appendix with a per-seed categorization-stability analysis, together with the categorization read at intermediate epochs and under a one-hidden-layer probe, covering the epoch, seed, and probe-quality dimensions, and we will clarify the recipe dependence alongside the definition.
[W3, Q3] For CMU-MOSI and CMU-MOSEI, can the authors provide a deeper unimodal analysis showing whether PGGB improves the audio and visual representations even when final multimodal accuracy changes little?
Response. Thank you for this suggestion. [NEW] We ran the requested analysis: post-hoc per-modality linear probes on the saved final checkpoints of all sentiment runs, mirroring the Appendix B.8 protocol (mean over 5 seeds).
CMU-MOSEI (probe accuracy %, baseline PGGB boost-only): text 64.95 66.43, audio 51.29 53.17, vision 59.78 60.09. PGGB does improve the weaker audio representation (+1.9 pp) and vision slightly (+0.3 pp), but text also rises (+1.5 pp), and OGM-GE shows the same all-modality pattern. The post-hoc utilization gap (distinct from the training-time of Q2) barely moves: 13.66 13.26 baseline vs. PGGB, 13.04 for the composition.
CMU-MOSI: text 70.99 71.72, audio 48.86 49.24, vision 54.49 53.47. Movements are within seed noise, and the post-hoc utilization gap does not narrow (22.13 22.48 pp).
The contrast with CREMA-D (App. B.8, PGGB+OGM-GE composition: weak visual probe +9.41 pp, strong audio probe -0.81 pp, gap reduced ) is the direct answer to your question: targeted weak-modality recovery occurs where the weak modality is undertrained (trainable encoders, severe imbalance), and it is a composition effect (App. B.8 shows boost-only does not recover the CREMA-D weak probe). On the text-dominant frozen-feature pipelines the probe movements are small and non-selective (the dominant text modality rises alongside the weak ones), leaving the utilization gap essentially unchanged, consistent with weak modalities that are intrinsically limited rather than suppressed. We will add the full probe tables to the appendix and fold the undertrained-versus-intrinsically-limited distinction into Section 5 and the Limitations.
[W4, Q4] On text-dominant sentiment tasks, would increasing alpha help the model learn more from weaker audio/visual modalities, or does it degrade performance because those modalities are intrinsically less informative? An alpha-sensitivity study on CMU-MOSI/MOSEI would be useful.
Response. Thank you for this useful suggestion. [NEW] Increasing neither helps nor degrades in the tested range. We ran the suggested -sensitivity study (boost-only, , seed 42) on both sentiment pipelines:
| Dataset | 0.25 | 0.5 | 0.75 | 1.0 | 1.5 | Range |
|---|---|---|---|---|---|---|
| CMU-MOSI | 73.32 | 72.74 | 72.89 | 73.03 | 72.59 | 0.73 pp |
| CMU-MOSEI | 70.24 | 70.24 | 70.68 | 71.33 | 70.68 | 1.09 pp |
On CMU-MOSI the grid spans 0.73 pp with no monotone trend. CMU-MOSEI is mildly positive to flat (range 1.09 pp). No degradation is observed at any tested , so we find no evidence that stronger boosting amplifies noisy, less informative modalities into accuracy loss; these are single-seed runs, and we will report the multi-seed version in the appendix. Conversely, raising also cannot unlock additional audio/visual learning here, because (per Q3) those representations are intrinsically limited rather than suppressed. We will state this scoping in the Limitations.
[Limitations] The limitations section should more directly address high-imbalance safety, sensitivity of the imbalance categorization, and the possibility that some weak modalities may be intrinsically less task-informative rather than merely undertrained.
Response. We fully agree and will expand the Limitations paragraph to cover all three items. The enhanced limitation text is presented as follows.
Limitations. Per-setting tuning is required and composition with throttling can regress when the dominance gap is small (worst case AVE-from-scratch -4.56 pp, Section 4.3.1), a regime our theory does not cover. The three propositions are safety properties: they bound the intervention and, under Prop. 3's conditions, preserve the standard descent guarantee at any imbalance level, but they do not guarantee gap closure, which is established empirically. The two datasets nearest the imbalance threshold (Twitter15 and CMU-MOSEI) carry the largest seed variances, so their categorization is provisional. Finally, PGGB does not distinguish modalities that are undertrained from modalities that are intrinsically less task-informative. Composition with throttling recovers the former (CREMA-D), while on the latter (the sentiment benchmarks) the weak-modality representations are essentially unchanged. This diagnosis is currently post-hoc, and developing an online criterion that separates the two cases is a promising direction for future work.
We thank you again for questions that directly shaped the expanded Limitations and the additional analyses, and we welcome any follow-up during the discussion period.
A Gentle Follow-up
Dear Reviewer gN93,
We appreciate your thoughtful feedback and wanted to briefly follow up on our response. We hope the added explanations and analyses have clarified the questions around high-imbalance stability, the dataset-level, and PGGB’s behavior on CMU-MOSI and CMU-MOSEI.
Should any points remain unresolved, we would be very happy to provide further clarification while the discussion period remains open, and we are committed to incorporating these explanations and revisions into the final manuscript. Thank you again for your time and consideration.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Author-AC Official Comment
We thank the AC for the careful meta-review, and especially for the concluding assessment that the probe-guided monitoring idea is original, simple, and suitable for a Concept and Feasibility contribution: exactly what we hoped to communicate. We answer the six points compactly (full detail in the public threads).
[1] CREMA-D discrepancy. 61.59 is our joint-training baseline, not OGM-GE's number. Peng et al. (CVPR 2022) report 61.9 for OGM-GE on CREMA-D (their Table 1, CREMA-D Acc column, Concatenation$\dagger$ row, and their Table 2, OGM-GE row, with their baseline at 51.7 and the 1-frame protocol in their Sec. 4.2). Our 1-frame ablation reproduces this at 62.47±1.42. Our main table uses the richer 3-frame protocol. We will relabel the rows to avoid confusion (miLe Q7).
[2] Adam. Reviewer miLe argued Adam's scale-invariance would absorb a gradient rescaling. Per-step instrumentation confirms it: under SGD the boost transmits essentially one-to-one to parameter updates (1.64 applied scale, 1.50 update-norm ratio), while Adam absorbs roughly two-thirds (1.48 applied, 1.17 update). The accuracy consequence, tested with the composed contrast at full budget under both optimizers on the identical CMU-MOSI pipeline (5 matched seeds): +1.69 pp under SGD (p=0.032, 5/5 seed pairs) and −0.09 pp under Adam (p=0.90). SGD is not retuned there, so the contrast is within-optimizer only (miLe W3).
[3] Isolating PGGB from OGM-GE. The isolating contrast is α=0 versus α=0.75 with OGM-GE active in both arms: at α=0 the scale is sm≡1, so the boost is off while the probe pipeline and the throttling stay identical, and the difference is attributable to boost actuation alone. At n=15 (final five seeds fixed in advance, all reported): 69.40±1.25 vs 71.00±1.46, +1.60 pp, 95% CI [0.59, 2.62], Welch p=0.0032, d=1.18, paired t p=0.016. The estimate moves with seed count: +2.31 (original 5) to +2.06 (n=10) to +1.60 (n=15). The original seeds were favorable draws and the later batches are not individually significant, so we report the pooled estimate, whose CI excludes zero. Table 2's 0.22 pp is the 1-frame setting, and the 3-frame decomposition becomes the primary ablation (miLe W4). Near-neutrality on the four low-imbalance benchmarks is intended behavior, and prior methods regress there (OGM-GE: KS −1.80, Twitter15 −0.27, Sarcasm −0.59, see miLe W2).
[4] Trajectories and warm-up (tQk1). All 500 probe events instrumented: the first event is at chance (raw 9.4%/15.6% against 16.67%), identification is correct from event 2 (iteration 39), and the ordering inverts only twice more, both where the near-zero gap's sign is estimator noise. Worst-case misdirection exposure is one K-step window at scale ≤1.23. No warm-up is needed. Measured overhead +1.61% for probes (+7.34% composed, largely OGM-GE's own), memory unchanged. Details are in response to tQk1 and plots will be added to appendix in the revised manuscript.
[5] Imbalance score and threshold (gN93). δ is the final-epoch EMA-smoothed probe gap during baseline training, 5-seed mean (App. B.9). Not tuned: the values split into a low group (0.017-0.150) and a high group (0.178-0.268), every threshold in [0.150,0.178) yields the identical categorization, and δ is measured before any method runs. Twitter15 and CMU-MOSEI are the seed-sensitive boundary cases and will be flagged, with the definition moved into Sec. 4.1 (gN93 Q2).
[6] Theory scoping. We agree the propositions are safety properties, not gap-closure or rate results. The abstract and introduction will be revised ("we establish three safety properties"). Details in tQk1 (W3) and gN93 (Q1).
Committed revisions: (1) n=15 statistics (sequentially extended, all runs reported) replace +2.31 everywhere, all 30 per-seed values in the appendix, baseline row relabeled. (2) measured overhead and the δ definition into Sec. 4.1. (3) optimizer dependence stated in Secs. 3.3 and 5, all measurements in the appendix. (4) abstract and introduction rescoped to safety properties. (5) early-window trajectory figure. (6) Limitations expanded (high-imbalance scoping, boundary cases, undertrained-versus-intrinsically-limited). (7) miLe's clarity fixes Q1-Q6.
Summary. gN93's questions each received additional analysis (the α-sweep is single-seed, multi-seed committed) plus drafted Limitations text. miLe's factual concern is resolved on the primary source, and their mechanism argument was confirmed by measurement, then tested at the accuracy level. One decision we explicitly defer to the AC: miLe's W1 on contribution type (we are comfortable under either criteria). We hope this response supports the meta-review's assessment, and we are glad to clarify any further comments or questions.