potentialpaper

ClinStab: Stability-Oriented Learning for Medical Time Series via Dual-Stream Alignment

Wenshuo Chen, Haoxuan Xu, Yi Liu, Songning Lai, Ninghui Feng, Jiayu Yang, Haoang Li, Yutao Yue

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

TL;DR. ClinStab improves the accuracy and perturbation stability of Medformer-based EEG and ECG classifiers through dual-stream signal processing and stability-aware training.

Abstract. Deep models for medical time series can achieve strong benchmark accuracy yet remain brittle under acquisition artifacts, physiological variability, and teacher-guided reduced-data training conditions. We present \textbf{ClinStab}, a Medformer-based framework for EEG and ECG classification that studies whether channel-aware dual-stream interaction and perturbation-aware optimization can improve the clean/robustness tradeoff. The proposed \textbf{S}alience-\textbf{C}ontext \textbf{D}ual \textbf{M}odulation (SCDM) module uses energy as a routing prior: high-energy channel-aligned components receive attentive modeling, while residual components remain trainable through a lightweight context pathway. ClinStab then combines clean supervision, perturbed supervision, prediction consistency, and teacher-guided stabilization under adversarial perturbations. Across four public datasets and 11 baselines, the reported local comparison improves accuracy over the local Medformer row on all datasets and improves selected robustness metrics under the perturbation settings studied here, while exposing tradeoffs on PTB ranking metrics and soft-routing alternatives. These results support ClinStab as a practical same-backbone stability intervention, not as evidence of universal clinical robustness. Code: https://github.com/xll0328/NeurIPS26-ClinStb.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
1 May 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:48 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

The paper addresses the potential instability in medical time series prediction models through the introduction of a module that handles high-energy components with attentive modeling, while routing residuals to a "a lightweight context pathway".

The reviewers appreciated the paper's motivation, as well as the scoping and modular design, stacking on top of Medformer. The ablation experiments were also seen as pertinent and comprehensive.

The authors should attempt to address the issues raised by the reviewers, especially:

  • formalize the notion of energy
  • address model calibration
  • introduce realistic noise models, address reliance on synthetic perturbations
  • analyze inductive bias
  • address the risk of systematic omission by the TopK mechanism
Final justification

According to the reviewers, the concerns were addressed.

Area Chair 739y · Meta-reviewOpenReview ↗
Final justification
According to the reviewers, the concerns were addressed.
Read meta-review
Meta-review

The paper addresses the potential instability in medical time series prediction models through the introduction of a module that handles high-energy components with attentive modeling, while routing residuals to a "a lightweight context pathway".

The reviewers appreciated the paper's motivation, as well as the scoping and modular design, stacking on top of Medformer. The ablation experiments were also seen as pertinent and comprehensive.

The authors should attempt to address the issues raised by the reviewers, especially:

  • formalize the notion of energy
  • address model calibration
  • introduce realistic noise models, address reliance on synthetic perturbations
  • analyze inductive bias
  • address the risk of systematic omission by the TopK mechanism
Reviewer JYtBOpenReview ↗
Rating
4/6
Confidence
4/5
Quality
2/4
Clarity
3/4
Significance
2/4
Originality
2/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper proposes ClinStab to improve the stability and robustness of EEG/ECG medical time series classification. The core module SCDM uses energy as the routing prior, feeding high-energy channels into the attention salience stream, while the remaining channels go through the lightweight convolutional context stream. The training objective combines clean/perturbed supervision, consistency, and teacher-guided stabilization, and uses perturbations such as AutoPGD for stress-test evaluation. The authors also explicitly emphasize the trade-off in the abstract and main text: for example, there is a trade-off between the PTB ranking metric and soft-routing alternatives.

Strengths and weaknesses

Strength

  • The problem statement is relatively honest: the paper avoids over-packaging the results as general clinical robustness in many places, instead emphasizing same-backbone stability intervention or stress-test proxy.
  • The design and ablation are relatively complete: it not only reports the average metrics but also provides routing alternatives, objective-only / SCDM-only / full breakdowns in the main text/appendix, and discusses that the decline in PTB ranking is not insignificant.
  • A multi-axis diagnosis of stability is provided: seed variance, Gaussian/structured corruption, etc., are more interpretable than a single robustness score.

Weakness

  • The authors emphasize that energy is only a routing proxy, which is correct, but it also implies that the clinical rationale for the methodology remains weak. Given this, the reason why hard TopK is a key mechanism for the robustness of medical time series data is not fully explained. Especially for low-amplitude but important anomalous signals, hard TopK may introduce a risk of systematic omission.
  • The decline in PTB ranking metrics is a substantial issue: the authors state that the decline in PTB AUROC/AUPRC is not a cosmetic issue (PDF p.8, L229–230), and the limitations section states that the decline in PTB ranking remains a real limitation (PDF p.9, L271–272). For medical models, this is not a marginal metric. In medical screening/ranking/threshold shift scenarios, the decline in AUROC/AUPRC is difficult to offset by simple accuracy gains; a more explicit discussion of threshold sensitivity/curve-level evidence and the risk of misdiagnosis is needed.
  • Robustness evidence still leans towards synthetic perturbations: The authors acknowledge that Lp perturbations are similar to structured corruption, and recent EEG adversarial robustness work typically emphasizes stability assessments under multiple attack, multiple perturbation intensities, and security scenarios; the 2025 ECG Transformer/LLM survey also points out that ECG transformer systems still face challenges in confidence, reliability, and clinical deployment. Therefore, relying solely on synthetic corruption and a single same-backbone recipe is insufficient to support a stronger narrative of clinical robustness.
Questions
  • Why was the hard TopK method ultimately chosen as the primary approach instead of the more stable and sometimes stronger soft-gate approach in terms of AUROC? I would appreciate a clearer explanation of the reasons and trade-offs regarding reproducibility, computational budget, and interpretability.
  • Please provide the ROC/PR curves for PTB, threshold sensitivity analysis, and discuss the potential risk of ranking decline in clinical ranking scenarios.
  • If the focus is on use-inspired/clinical robustness: Could you provide at least one assessment that more closely approximates a real-world acquisition artifact, or external data validation? Otherwise, I suggest further downplaying the clinical robustness wording.
Limitations

The authors acknowledge that energy is merely a routing proxy, Lp-bounded perturbations and structured corruptions are only approximations of clinical acquisition artifacts, soft routing is sometimes stronger, PTB ranking decline is a real limitation, AutoPGD increases training costs, and low-data experiments are teacher-guided, not purely low-resource learning. These limitations precisely indicate that this paper should be viewed as an engineering-oriented stability intervention, rather than a method with strong clinical robustness.

Final justification

As most of my concerns resolved during the rebuttal, I will raise my rating from 3 to 4.

Formatting concerns

None.

3 comments
Authors · RebuttalOpenReview ↗
Rebuttal

Thank you for identifying the decision-critical issues. We agree that ClinStab must be evaluated through its routing failure modes, PTB ranking behavior, and the gap between synthetic stress tests and clinical conditions rather than through clean accuracy alone. The analyses below narrow, rather than broaden, the supported claim.

1. TopK excludes channels from attention, not from the representation; residual under-modeling remains possible. We agree that the central risk is whether context-only processing can under-model low-amplitude patterns that require attentive cross-channel interaction. Eq. (2) defines channel energy and Eq. (3) partitions channels into salience and context sets. Every non-TopK channel is processed by a depth-wise context convolution, returned to its original order, fused with the attention branch, and retained through the residual path (pp. 4-5). Removing the context stream lowers accuracy by 1.49/1.26/0.55/1.37 points on APAVA/TDBrain/ADFTD/PTB, and the low-energy attenuation diagnostic improves over Medformer by 3.8/2.4/1.1/1.6 points (Table 5).

These diagnostics show continued use of residual channels, but they do not establish adequate attentive modeling of every subtle abnormality. Table 7 exposes a complementary failure: the corrupted channel enters the salience set with frequency 0.78-0.88 for high-amplitude artifacts, and soft routing has numerically smaller mean drops in these severe cases. Across the four datasets, Full ClinStab's mean accuracy is 0.38-1.13 points higher than the matched Medformer+stability-loss control (Table 6), supporting a modest cross-dataset routing contribution. Energy is therefore only a computational routing prior, not clinical feature attribution.

2. Hard routing is a fixed-budget accuracy choice; soft routing remains a ranking candidate. On the matched APAVA routing ablation, hard TopK vs. soft gating gives 79.34 vs. 78.81 mean clean accuracy, 61.11 vs. 60.18 mean accuracy at σ=3\sigma=3, 85.48 vs. 85.61 mean AUROC, and 0.16 vs. 0.18 route-flip rate (Table 8). The default α=4.67\alpha=4.67 allocates 21% of channels to attention (Table 10). We chose hard routing for a fixed attention budget, deterministic, inspectable assignments for a given input, and the numerically highest reported mean clean/robust-accuracy point, not because it dominates soft routing.

Table 27 reports the full default's cost relative to Medformer: 1.82 times training time per epoch, 1.67 h total training time, 1.04 times inference latency, and 1.11 times peak memory. Thus, most added cost is concentrated in robustness training in the reported setup. We did not separately benchmark hard-vs.-soft end-to-end latency and do not claim a measured latency advantage for hard routing. Soft gating is a candidate to evaluate for ranking-first or severe-artifact settings.

3. PTB loses global ranking and remains operating-point dependent. We agree that accuracy cannot erase the ranking risk. The submitted result is AUROC 93.20 -> 90.22 and AUPRC 92.67 -> 90.13, with declines of -2.98 (nominal paired p=0.021p=0.021) and -2.54 (nominal paired p=0.028p=0.028). ECE and Brier move in the opposite direction: 0.092 -> 0.061 and 0.158 -> 0.142, respectively.

Using each seed's held-out predictions, we summarize ROC/PR behavior through the full-curve AUROC/AUPRC values above and five validation-selected, test-frozen operating points below; complete ROC/PR plots will be added to the revision. Thresholds were derived only from validation data and frozen before test evaluation. The table does not establish curve-wide superiority. To avoid treating a validation target as an achieved test rate, we report both the achieved rate and its paired metric:

Validation target Medformer test result ClinStab test result
90% specificity 89.4 +/- 0.8 spec / 75.6 +/- 1.7 sens 89.1 +/- 0.9 spec / 73.8 +/- 1.6 sens
95% specificity 94.3 +/- 0.6 spec / 61.5 +/- 1.9 sens 94.5 +/- 0.5 spec / 64.2 +/- 1.7 sens
97.5% specificity 97.0 +/- 0.4 spec / 47.9 +/- 2.0 sens 96.9 +/- 0.5 spec / 51.2 +/- 1.8 sens
80% recall 79.4 +/- 0.9 recall / 89.8 +/- 1.2 precision 79.1 +/- 1.0 recall / 87.4 +/- 1.4 precision
90% recall 89.2 +/- 0.8 recall / 80.6 +/- 1.8 precision 88.9 +/- 0.9 recall / 77.9 +/- 2.0 precision

This validation-selected, test-frozen analysis yields values slightly different from Table 19's single reported point; we report both without treating them as directly interchangeable. Across these prespecified targets, operating-point ordering reverses: ClinStab has numerically higher mean sensitivity at the 95% and 97.5% specificity targets, but lower mean sensitivity at the 90% target and lower mean precision at both fixed-recall targets. At the 90% target, lower mean sensitivity implies more missed positives; at fixed recall, lower mean precision implies more false alarms. These five-seed differences are descriptive, with no new significance claim. Together with lower AUROC/AUPRC, this means the default should not be treated as uniformly preferable for ranking or threshold-shift scenarios. Table 20 further shows that reducing robustness and consistency weights partially recovers ranking to 92.11 AUROC/91.94 AUPRC, but reduces accuracy and robustness.

4. Added tests yield smaller degradation in 8/8 accuracy and 7/8 AUROC/ECE comparisons, but remain synthetic. No recorded-artifact cohort, external-site study, or prospective validation is available. The nearest evidence is therefore a controlled synthetic acquisition-like stress suite, not clinical validation. Beyond the submitted Gaussian, structured-corruption, and adversarial checks, we evaluated separate 50/60-Hz powerline interference, channel gain, random spikes, and multi-channel bursts on APAVA and PTB with paired corruption draws and five common seeds. ClinStab has the smaller mean accuracy drop in all eight dataset/corruption pairs and the smaller mean AUROC drop and ECE increase in seven; PTB gain scaling is the disclosed reversal for AUROC/ECE:

Dataset / corruption Accuracy drop, Medformer / ClinStab (pp) AUROC drop, Medformer / ClinStab (pp) ECE increase, Medformer / ClinStab
APAVA / powerline 5.2 / 3.5 4.2 / 3.0 0.028 / 0.018
APAVA / gain 2.4 / 1.7 1.7 / 1.1 0.014 / 0.009
APAVA / spikes 7.3 / 5.0 5.6 / 3.8 0.041 / 0.027
APAVA / burst 9.1 / 6.4 7.0 / 5.0 0.055 / 0.037
PTB / powerline 4.4 / 3.2 3.6 / 2.6 0.024 / 0.017
PTB / gain 2.8 / 1.9 1.9 / 2.1 0.016 / 0.017
PTB / spikes 6.1 / 4.6 5.2 / 3.8 0.036 / 0.026
PTB / burst 7.7 / 5.8 6.6 / 4.8 0.048 / 0.034

These results partially address the requested acquisition-like assessment but do not close the synthetic-to-clinic gap.

In summary, residual channels are retained but may remain under-modeled; hard routing is not uniformly superior; PTB ranking worsens; and synthetic stress tests do not close the clinical evidence gap. Accordingly, the supported contribution is a transparent same-backbone stability intervention with quantified routing, ranking, and artifact failure modes, not a clinically validated or uniformly superior robustness method.

Reviewer JYtB · CommentOpenReview ↗

Thanks for your detailed response. I think most of my concerns are resolved based on the above illustration.

Authors · CommentOpenReview ↗

Thank you for your positive feedback! We sincerely appreciate your time and constructive comments throughout the review process.

Reviewer NHnZOpenReview ↗
Rating
4/6
Confidence
5/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This study addresses a common issue in medical time-series classification (such as EEG and ECG) that models achieve high accuracy on clean test sets but exhibit unstable predictions when faced with sensor noise, motion artifacts, sampling defects, or physiological inter-individual differences. The authors define their objective as diagnostic stability which means the model's output distribution should not undergo drastic changes in response to minor input perturbations. The paper explicitly states that it models stability only under the specific perturbations evaluated, rather than demonstrating universal clinical robustness.

The core method ClinStab is built upon the Medformer backbone. It comprises two main components: first, SCDM, which utilizes energy as a routing prior to direct high-energy channel components into an attention branch and the remaining components into a lightweight convolutional context branch; and second, a stability training objective that integrates supervision from clean and perturbed samples, prediction consistency between clean and perturbed inputs, and KL-divergence-based distillation from a frozen Medformer teacher model.

Strengths and weaknesses

Strengths

I believe the primary merit of this paper lies in the fact that it does not merely pursue higher benchmark accuracy. Instead, it focuses on a more practical issue inherent to medical time-series data: prediction instability caused by perturbations. The paper highlights how EEG/ECG models can exhibit fragile decision boundaries when faced with factors such as sensor noise, motion artifacts, and physiological inter-individual differences. This problem formulation is clinically relevant and holds greater value than simply squeezing out incremental gains in accuracy.

The methodological approach is clearly defined. ClinStab does not claim to introduce an entirely new large-scale model; instead, it applies stability-focused interventions to an existing medical time-series backbone, Medformer. Specifically, it replaces the interaction layer with SCDM and incorporates a perturbation-aware training objective. As a reviewer, I appreciate this same-backbone intervention design, as it makes it easier to pinpoint the source of performance gains without them being obscured by differences in the underlying backbone.

The design of SCDM is reasonably sound. Rather than simply equating high-energy channels with clinically significant ones, the authors emphasize that energy serves merely as a routing prior: high-energy components are processed via attention, while low-energy or residual components continue training through the context stream before final fusion. This approach is prudent, given that low-amplitude abnormalities in medical signals, such as subtle ST-segment shifts, can also be clinically important.

The training objectives are comprehensive. They encompass clean supervision, perturbed supervision, consistency between clean and perturbed predictions, and KL distillation using a frozen teacher. This approach is more systematic than relying solely on Gaussian augmentation or adversarial training, and the objectives align with the concept of local prediction stability.

Comments and Suggestions for the Authors

Beside the pros, I have several comments and suggestion for the author.

First, further refine the description of the contributions. The current manuscript is already quite measured,explicitly characterizing ClinStab as a "same-backbone stability intervention" rather than "universal clinical robustness," which is a strength. It is recommended to maintain consistency in this phrasing across the Abstract, Introduction, and Conclusion, avoiding strong terms like "clinical robustness" or "diagnostic reliability" that could easily be misinterpreted as implying actual clinical validation.

Second, although Table 4 already includes ablation studies for random-split SCDM, soft energy gate, and SCDM-only configurations, the specific inductive bias introduced by high-energy Top-K remains unclear. I suggest adding a more explicit analysis comparing the results of random split, variance Top-K, learned gate, soft gate, and hard TopK, either in the main text or in a appendix, rather than simply stating that "hard Top-K represents a deterministic operating point." Current results show that the soft energy gate actually achieves a slightly higher AUROC, whereas hard Top-K excels primarily in accuracy and robustness at σ=3\sigma=3; therefore, you should frame it as a "deterministic routing strategy preferred for deployment" rather than as a "universally optimal routing strategy."

Third, strengthen the justification for the real-world clinical perturbations used. While Gaussian noise, structured corruption, and AutoPGD serve as useful stress tests, they still differ significantly from actual EEG/ECG acquisition artifacts. I suggest adding a subsection that systematically explains which specific acquisition issues correspond to each type of perturbation. This would make the robustness experiments resemble a "medical signal stress protocol" rather than a generic adversarial robustness setup.

Fourth, on the PTB dataset, ClinStab improved accuracy, recall, and F1, though its AUROC and AUPRC scores were lower than those of Medformer. I suggest elevating it from a "limitation" to failare case analysis. You could add a brief paragraph to the main text discussing why stability training enhances operating performance near specific thresholds while simultaneously compromising overall ranking quality.

Fifth, we strengthen the argument regarding cross-subject generalization. ADFTD employs subject-dependent splits, whereas APAVA, TDBrain, and PTB use subject-independent splits. This distinction is crucial because, in medical time-series data, subject leakage or subject-dependent evaluation can significantly inflate performance scores.

Sixth, experiments involving "low-resource" settings need to be renamed or downplayed. What is currently termed "reduced-data training" is, in fact, a process of student robustification or compression guided by a fixed full-data teacher; it is not strictly "low-resource learning."

Questions

See Comments and Suggestions for the Authors

Limitations

Yes

Final justification

The authors addressed my concerns.

Formatting concerns

No

1 comment
Authors · RebuttalOpenReview ↗
Rebuttal

Thank you for the careful review. We agree with the requested framing and address each point directly.

1. Scope is stability under evaluated stress tests, not clinical validation. We maintain the reviewer's recommended interpretation consistently: ClinStab is a same-backbone stability intervention under the evaluated stress tests, not a clinically validated robustness method. The Abstract, Methodology, and Limitations bound the claim to stress-test proxies; no diagnostic-reliability guarantee, external-site validation, or universal clinical robustness is claimed.

2. Hard TopK is a fixed-budget accuracy point, not a universal winner. Table 8 (p. 15) compares the requested random split, variance TopK, learned gate, soft energy gate, and hard Energy TopK under the same two-stream template. On this APAVA routing ablation, their accuracy/AUROC/accuracy at σ=3\sigma=3 are 77.42/82.91/57.80, 78.05/83.66/59.10, 78.58/84.46/59.86, 78.81/85.61/60.18, and 79.34/85.48/61.11. Hard TopK has the numerically highest mean clean and robust accuracy, whereas soft gating's mean AUROC is numerically 0.13 points higher. We selected hard routing as a reproducible fixed-attention-budget operating point with deterministic assignments for a given input, not as a universally optimal strategy; soft routing is a candidate to evaluate for ranking-first settings.

Table 6 (p. 14) further shows that Full ClinStab's mean accuracy is 0.38-1.13 points higher than the matched Medformer+stability-loss control across APAVA, TDBrain, ADFTD, and PTB. This supports a modest compatible inductive bias rather than attributing all gains to energy TopK.

3. Residual channels remain represented, but attentive under-modeling remains possible. TopK excludes residual channels from attention, not from the representation. Every non-TopK channel is processed by the context stream and retained through fusion and residual connections. Removing that stream reduces accuracy by 1.49/1.26/0.55/1.37 points on APAVA/TDBrain/ADFTD/PTB (Table 5), and the low-energy attenuation diagnostic improves over Medformer by 3.8/2.4/1.1/1.6 points. These results show continued use of low-energy inputs, but they do not rule out under-modeling of subtle patterns that require attentive cross-channel interaction. Energy is therefore a routing prior, never a clinical-salience detector.

4. Four added tests yield smaller degradation in 8/8 accuracy and 7/8 AUROC/ECE comparisons. The submitted mappings are: channel/lead dropout to contact loss; baseline drift to respiration/electrode wander; temporal masking to packet/segment loss; resampling jitter to sampling-clock defects; and burst/pop/saturation to transient motion, contact failure, or clipping. We further evaluated separate 50/60-Hz powerline interference, channel gain, random spikes, and multi-channel bursts on APAVA and PTB using paired corruption draws and five common seeds. ClinStab has the smaller mean accuracy drop in all eight dataset/corruption pairs and the smaller mean AUROC drop and ECE increase in seven; PTB gain scaling is the disclosed reversal for AUROC/ECE. For compactness, the table gives the unweighted two-dataset macro-average of the APAVA and PTB mean drops, not a sample-pooled estimate; each dataset was also checked separately.

Corruption Accuracy drop, Medformer / ClinStab (pp) AUROC drop, Medformer / ClinStab (pp) ECE increase, Medformer / ClinStab
Powerline 4.8 / 3.4 3.9 / 2.8 0.026 / 0.018
Channel gain 2.6 / 1.8 1.8 / 1.6 0.015 / 0.013
Random spikes 6.7 / 4.8 5.4 / 3.8 0.039 / 0.027
Multi-channel burst 8.4 / 6.1 6.8 / 4.9 0.052 / 0.036

The PTB gain reversal is therefore retained rather than averaged away. These remain controlled synthetic acquisition-like tests, not recorded-artifact or external clinical validation.

5. PTB is a failure/tradeoff case, not a uniform screening gain. We agree that the ranking decline is clinically material. Table 15 reports ΔAUROC\Delta\mathrm{AUROC} = -2.98 (nominal paired p=0.021p=0.021) and ΔAUPRC\Delta\mathrm{AUPRC} = -2.54 (nominal paired p=0.028p=0.028) versus Medformer. Table 19 shows the opposing operating-point evidence: accuracy 79.84 -> 82.12, ECE 0.092 -> 0.061, Brier 0.158 -> 0.142, and sensitivity at 95% specificity 61.8 -> 64.9.

We additionally selected thresholds on each seed's validation set and froze them for test evaluation. At validation specificity targets of 90%, 95%, and 97.5%, the achieved test specificity/sensitivity pairs for Medformer vs. ClinStab are 89.4/75.6 vs. 89.1/73.8, 94.3/61.5 vs. 94.5/64.2, and 97.0/47.9 vs. 96.9/51.2. At validation recall targets of 80%/90%, achieved test precision is 89.8/80.6 for Medformer vs. 87.4/77.9 for ClinStab at comparable achieved recall. This validation-selected, test-frozen analysis yields values slightly different from Table 19's single reported point; we report both without treating them as directly interchangeable. Thus, operating-point ordering changes: ClinStab has numerically higher mean sensitivity at the two higher-specificity targets, but lower mean sensitivity at the 90%-specificity target, lower mean precision at fixed recall, and worse global ranking. These five-seed differences are descriptive, with no new significance claim. It is not uniformly preferable for screening.

6. ADFTD is interpreted only under its stated subject protocol. APAVA, TDBrain, and PTB use subject-independent splits; ADFTD follows the benchmark subject-dependent split. We interpret ADFTD only as in-protocol utility. Table 21 shows that, relative to benchmark-split accuracy of 97.48/98.29 for Medformer/ClinStab, absolute accuracy falls to 88.64/90.21 under the additional subject-blocked check.

7. The reduced-data setting is teacher-guided, not pure low-resource learning. We relabel this setting as teacher-guided reduced-data robustification/compression and withdraw a pure low-resource interpretation. The fixed teacher sees the full clean training split, whereas the student sees a reduced subset. Table 17 separately reports teacher-free and subset-matched controls.

In summary, hard routing is a budgeted APAVA accuracy choice; residual under-modeling and PTB ranking remain explicit failure modes; and the ADFTD and reduced-data claims are bounded by their protocols. These qualifications retain the central same-backbone contribution while making the routing, perturbation, PTB, split, and reduced-data boundaries explicit.

Reviewer 9gHPOpenReview ↗
Rating
5/6
Confidence
3/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper focuses on stability-oriented medical time series classification under noisy data scenarios. The authors present ClinStab, which is a framework for ECG/EEG time series classification that combines a focal-context interaction layer with stability-oriented training. They propose an SCDM module that uses energy to determine routing of data to either an attentive modeling component or to a lightweight context pathway. Then, training is done using the following four items: clean supervision, perturbed supervision, prediction consistency, and teacher-guided stabilization. Lastly, experimental results are presented that showcase the performance of ClinStab over 4 public datasets.

Strengths and weaknesses

Strengths:

The authors motivate the problem at hand well

Related work section is structured nicely and contains good detail

The proposed method is described fairly clearly

Proposed method is compared against a good volume of prior methods for proper assessment

Performance results are obtained across a set of random seeds instead of from single runs

The plots for performance are pretty neat and easy to understand.

I appreciate the amount of experimental comparisons done by the authors in the main paper and the appendix.

Weaknesses/Areas for Improvement:

Would be good to get a formal definition of energy and how it is calculated before it is pervasively used, just for completeness.

Some design choices in the methodology are not motivated/bolstered as well as they could be.

There does not seem to be a mention of model calibration, but incorporating calibration analysis would strengthen the work.

Would be curious to see robustness performance under different forms of simulated yet realistic noise. Figure 3(b) is nice and focuses on gaussian noise degradation on one dataset with 2 methods - more visuals of this type would be great. Appendix D2 explores noise performance further, but it would be interesting to see more of this as real world acquisition is indeed imperfect. As an example, looking at metrics beyond accuracy would be insightful. In terms of noises, additional realistic perturbations such as random spike noise, amplitude scalings, multi-channel corruptions, or narrowband inference can be explored.

Questions

Why was MSE chosen for the diagnostic consistency loss? Would a different modeling choice better capture the probabilistic structure of outputs?

How would accuracy results change under different types of noise reflecting real clinical artifacts beyond gaussian noise? Going a bit further than what Appendix D2 shows (as mentioned above).

How can model calibration be explored? It would be good to have an understanding of how the model can be honest about its uncertainty. Calibration error metrics can be used to explore this.

Limitations

Yes, authors have an explicit and detailed limitations section in their submission.

Final justification

The authors did a good job addressing my comments and it seems like they did the same for the other reviewers.

Formatting concerns

None.

3 comments
Authors · RebuttalOpenReview ↗
Rebuttal

Thank you for the constructive review. We address the main concerns directly and report three focused analyses using the submitted splits, checkpoints, and five seeds: acquisition-like corruptions, APAVA calibration, and a validation-selected, test-frozen PTB threshold sweep.

1. Energy is explicitly defined; TopK routes rather than discards channels. For the channel-aligned hidden tensor X(i)∈RNi×C×dhX^{(i)}\in\mathbb{R}^{N_i\times C\times d_h}, Eq. (2), p. 4 defines

Ec=1Ni∑n=1Ni∥Xn,c,:(i)∥22.\mathcal E_c=\frac{1}{N_i}\sum_{n=1}^{N_i}\lVert X^{(i)}_{n,c,:}\rVert_2^2.

Thus, energy is the mean squared L2 norm of channel cc's hidden trajectory over temporal patches at granularity ii. Eq. (3) selects k=⌊C/α⌋k=\lfloor C/\alpha\rfloor channels for attention. TopK assigns interaction type rather than discarding information: every non-TopK channel is processed by the context convolution, restored to its original order, and retained through fusion and the residual path (pp. 4-5).

The design is evaluated in Tables 5-10 (pp. 14-15) through stream removal, objective-only/SCDM-only/full decomposition, and random, variance, learned, soft, and hard routing controls. On the APAVA routing ablation, hard vs. soft routing gives 79.34 vs. 78.81 mean clean accuracy, 61.11 vs. 60.18 mean accuracy at σ=3\sigma=3, and 85.48 vs. 85.61 mean AUROC. We therefore use hard TopK as a fixed-budget, inspectable clean/robust-accuracy operating point, not as a universally optimal router; soft routing is a candidate to evaluate when ranking quality is the priority.

2. MSE and KL serve distinct symmetric and teacher-directed roles. The consistency term compares class-probability vectors, Lcon=∥p(y∣x)−p(y∣x+δ)∥22L_{\mathrm{con}}=\lVert p(y|x)-p(y|x+\delta)\rVert_2^2 (Eq. (8), p. 5). MSE is a symmetric, direct penalty on local probability movement and requires neither prediction to be designated as the reference. The separate knowledge-preservation term already uses directional, temperature-scaled KL from the frozen clean teacher to the perturbed student (Eq. (9)). JS or KL could also be principled choices, but the submission contains no MSE-vs.-JS/KL ablation; our supported claim is a role-specific design rationale, not empirical or universal superiority.

3. Four added tests yield smaller degradation in 8/8 accuracy and 7/8 AUROC/ECE comparisons. The submission evaluates EMG/motion bursts, electrode pops, lead saturation, baseline drift, channel/lead dropout, temporal masking, resampling jitter, and single-channel bursts (Tables 7 and 13). We additionally evaluated the reviewer-suggested perturbations on APAVA and PTB: separate 50- and 60-Hz powerline interference at 0.1 times per-channel RMS, gain scaling on 25% of channels with U(0.5,1.5)U(0.5,1.5), signed 3-SD spikes at 1% of time points in 25% of channels, and a shared-window Gaussian burst (3 SD, 10% duration) in 25% of channels. ClinStab has a smaller mean accuracy drop in all eight dataset/corruption pairs and smaller mean AUROC drop and ECE increase in seven of eight; PTB gain scaling is the disclosed reversal for AUROC/ECE. Corruption draws were paired between models, applied after the original normalization, and not renormalized. The powerline row averages the separately evaluated 50- and 60-Hz conditions. Values are five-seed mean +/- SD clean-to-corrupted changes; lower is better.

Dataset / corruption Accuracy drop, Medformer / ClinStab (pp) AUROC drop, Medformer / ClinStab (pp) ECE increase, Medformer / ClinStab
APAVA / powerline 5.2 +/- 0.6 / 3.5 +/- 0.5 4.2 +/- 0.7 / 3.0 +/- 0.6 0.028 +/- 0.004 / 0.018 +/- 0.003
APAVA / gain 2.4 +/- 0.4 / 1.7 +/- 0.3 1.7 +/- 0.4 / 1.1 +/- 0.3 0.014 +/- 0.003 / 0.009 +/- 0.002
APAVA / spikes 7.3 +/- 0.8 / 5.0 +/- 0.6 5.6 +/- 0.8 / 3.8 +/- 0.6 0.041 +/- 0.005 / 0.027 +/- 0.004
APAVA / multi-channel burst 9.1 +/- 1.0 / 6.4 +/- 0.8 7.0 +/- 0.9 / 5.0 +/- 0.7 0.055 +/- 0.007 / 0.037 +/- 0.005
PTB / powerline 4.4 +/- 0.5 / 3.2 +/- 0.4 3.6 +/- 0.6 / 2.6 +/- 0.5 0.024 +/- 0.004 / 0.017 +/- 0.003
PTB / gain 2.8 +/- 0.4 / 1.9 +/- 0.3 1.9 +/- 0.4 / 2.1 +/- 0.4 0.016 +/- 0.003 / 0.017 +/- 0.003
PTB / spikes 6.1 +/- 0.7 / 4.6 +/- 0.6 5.2 +/- 0.7 / 3.8 +/- 0.6 0.036 +/- 0.005 / 0.026 +/- 0.004
PTB / multi-channel burst 7.7 +/- 0.9 / 5.8 +/- 0.7 6.6 +/- 0.8 / 4.8 +/- 0.7 0.048 +/- 0.006 / 0.034 +/- 0.005

The PTB gain row shows the exception directly: ClinStab retains the smaller mean accuracy drop but has a slightly larger mean AUROC drop and ECE increase. These are controlled synthetic acquisition-like stress tests, not recorded-artifact or external clinical validation.

4. APAVA ECE/Brier are lower; PTB remains operating-point dependent. We extended clean calibration to APAVA using the same five seeds and the same implementation as the submitted PTB analysis:

Dataset ECE, Medformer / ClinStab Brier, Medformer / ClinStab
APAVA 0.112 +/- 0.010 / 0.083 +/- 0.009 0.169 +/- 0.008 / 0.154 +/- 0.007
PTB (submitted Table 19) 0.092 / 0.061 0.158 / 0.142

Both ECE and Brier are lower for ClinStab on these held-out distributions. ECE measures a binned confidence-accuracy gap, whereas Brier is a proper score over the full probability vector; neither establishes per-patient uncertainty quality or clinical reliability.

On PTB, global ranking decreases from 93.20/92.67 to 90.22/90.13 in AUROC/AUPRC. To characterize operating-point sensitivity without test-set threshold selection, we selected thresholds independently for each seed and model on validation data and froze them for test evaluation. We report each achieved test operating rate together with its paired metric:

Validation target Medformer test result ClinStab test result
90% specificity 89.4 +/- 0.8 spec / 75.6 +/- 1.7 sens 89.1 +/- 0.9 spec / 73.8 +/- 1.6 sens
95% specificity 94.3 +/- 0.6 spec / 61.5 +/- 1.9 sens 94.5 +/- 0.5 spec / 64.2 +/- 1.7 sens
97.5% specificity 97.0 +/- 0.4 spec / 47.9 +/- 2.0 sens 96.9 +/- 0.5 spec / 51.2 +/- 1.8 sens
80% recall 79.4 +/- 0.9 recall / 89.8 +/- 1.2 precision 79.1 +/- 1.0 recall / 87.4 +/- 1.4 precision
90% recall 89.2 +/- 0.8 recall / 80.6 +/- 1.8 precision 88.9 +/- 0.9 recall / 77.9 +/- 2.0 precision

This validation-selected, test-frozen analysis yields values slightly different from Table 19's single reported point; we report both without treating them as directly interchangeable. Across the reported targets, the operating-point ordering reverses: ClinStab has numerically higher mean sensitivity at the two higher-specificity targets but lower mean sensitivity at the 90%-specificity target and lower mean precision at the fixed-recall targets. These five-seed differences are descriptive, with no new significance claim. Together with lower AUROC/AUPRC, this is a threshold-dependent tradeoff, not uniformly better screening.

In summary, energy is formalized, MSE and KL have distinct roles, the added stress tests cover four requested perturbations and three metrics, and APAVA/PTB expose lower ECE/Brier alongside an explicit PTB ranking-threshold tradeoff. These results support the deliberately bounded conclusion: ClinStab is a same-backbone stability intervention under specified stress tests, not evidence of universal clinical robustness.

Reviewer 9gHP · CommentOpenReview ↗

Thank you for the detailed response to my comments and the additional experiments. My concerns have been adequately addressed.

Authors · CommentOpenReview ↗

Thank you for your encouraging feedback! We greatly appreciate your thoughtful comments and valuable guidance throughout the review process.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Missing a submission?

Loading the discussion…