Augmented Equivariant Mesh Networks for Anatomical Segmentation
Daniel Saragih
NeurIPS 2026
TL;DR. We present EAMS, a lightweight equivariant mesh segmentation framework augmented with anatomy-aware features and long-range context modules.
Abstract. Anatomical mesh segmentation requires models that operate directly on irregular surface geometry while remaining robust to arbitrary patient pose and mesh resolution variation. Existing task-specific mesh and point-cloud methods are not equivariant, and can degrade sharply under test-time perturbation, for example dropping by 25-26 IoU points on intraoral scan segmentation at 40$\textdegree{}$ tilt. We present EAMS, an Equivariant Anatomical Mesh Segmentor built on Equivariant Mesh Neural Networks (EMNN), and evaluate it across four clinically distinct tasks spanning edge-, vertex-, and face-level supervision. We combine intrinsic mesh descriptors with anatomy-aware priors, including PCA-derived frames for dental arches and liver surfaces, and augment message passing to provide lightweight global context. Across intracranial aneurysm and intraoral segmentation, EAMS variants are competitive with specialized baselines on unperturbed inputs while remaining stable under geometric perturbations, and on liver surfaces they expose a favorable trade-off between canonical-pose accuracy and rotation robustness. These results show that a lightweight (M parameters) equivariant framework can deliver robust anatomical mesh segmentation across diverse supervision types without task-specific architectures.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:45 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
This paper studies whether one lightweight equivariant mesh network can deliver pose-robust anatomical segmentation across several anatomies and supervision types. It received one accept and two borderline accepts.
I have read the authors' response, and it resolved the fairness question that drove my initial meta-review. The authors retrained every non-equivariant baseline with the same rotation augmentation, splits, and model selection as their own model. Matched augmentation improves the baselines, but it does not close the gap: at 40 degrees the strongest augmented baselines stay well below the equivariant model on the aneurysm, intraoral, and liver tasks. So the reported robustness is not an artifact of unequal augmentation. The authors also added a factorial ablation with a parameter-matched control that separates the module gains from added capacity, a pose diagnostic that explains the liver trade-off, and a stability analysis of the anatomy-aware frames. The borderline-reject reviewer raised the score and credited the matched-baseline result directly.
I recommend acceptance. This is a useful and honest multi-anatomy robustness study with a compact model, and the central claim now rests on a fair comparison.
The authors should fold the matched-baseline results and the factorial ablation into the paper, separate the exact-invariance claim on the aneurysm task from the approximate-canonicalization results on the dental and liver tasks, and release the code and preprocessing as promised.
Final justification
Accept. The rebuttal resolved the decisive baseline-fairness question: matched-augmentation baselines still fall well below EAMS at 40 degrees, and a parameter-matched factorial ablation isolates the module gains. One reviewer raised 3 to 4 on this basis; the other two are positive.
Read meta-review
Meta-review
This paper studies whether one lightweight equivariant mesh network can deliver pose-robust anatomical segmentation across several anatomies and supervision types. It received one accept and two borderline accepts.
I have read the authors' response, and it resolved the fairness question that drove my initial meta-review. The authors retrained every non-equivariant baseline with the same rotation augmentation, splits, and model selection as their own model. Matched augmentation improves the baselines, but it does not close the gap: at 40 degrees the strongest augmented baselines stay well below the equivariant model on the aneurysm, intraoral, and liver tasks. So the reported robustness is not an artifact of unequal augmentation. The authors also added a factorial ablation with a parameter-matched control that separates the module gains from added capacity, a pose diagnostic that explains the liver trade-off, and a stability analysis of the anatomy-aware frames. The borderline-reject reviewer raised the score and credited the matched-baseline result directly.
I recommend acceptance. This is a useful and honest multi-anatomy robustness study with a compact model, and the central claim now rests on a fair comparison.
The authors should fold the matched-baseline results and the factorial ablation into the paper, separate the exact-invariance claim on the aneurysm task from the approximate-canonicalization results on the dental and liver tasks, and release the code and preprocessing as promised.
Final justification
Accept. The rebuttal resolved the decisive baseline-fairness question: matched-augmentation baselines still fall well below EAMS at 40 degrees, and a parameter-matched factorial ablation isolates the module gains. One reviewer raised 3 to 4 on this basis; the other two are positive.
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 2/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper tackles anatomical segmentation on 3D surface meshes, where models must be robust to both arbitrary patient pose and variation in mesh resolution. The authors propose EAMS, a lightweight (<2M parameter) segmentor built on Equivariant Mesh Neural Networks that combines intrinsic geometric descriptors with anatomy-aware PCA-derived coordinate frames for global context. It further introduces two complementary message-passing extensions trained with several auxiliary regularization losses. The method is evaluated on three clinically distinct tasks spanning edge-, face-, and vertex-level supervision (liver surfaces, intraoral scans, and intracranial aneurysms), against point-cloud and mesh baselines under both canonical and rotated inputs.
Strengths and weaknesses
Strengths
This paper identifies a genuine and underserved problem: segmenting anatomical surface meshes in a way that is simultaneously robust to patient pose and to wide variation in mesh resolution. The authors evaluate across three clinically distinct datasets that span edge-, face-, and vertex-level supervision, compare against several relevant baselines. On clarity, the paper is well organized and pairs its equations with helpful intuition, and the explicit limitations section aids understanding. On significance, the unified multi-task benchmark gives the community a useful reference point and a parameter-efficient framework to build on. On originality the anatomy-aware frame construction within an equivariant backbone is an inspring idea.
Weaknesses
The principal weakness concerns originality. Most of the core ingredients like equivariant mesh networks, intrinsic descriptors, and the assortment of regularization losses, are drawn from existing work. The rationale for the two augmented message passing modules and the regularization losses are underspecified. In addition, it is not quite clear how frequently large pose perturbations actually occur in clinical scenarios, and the robustness advantage is to some degree rather than a new capability. This raises the concern of fair comparison that baselines maybe tested under rotations they are simply not built to handle. On clarity, many system details are deferred to appendices, so the main text alone would have risk about faithful reproduction.
Questions
-
The paper uses SRA and VN generically as ways to extend the receptive field, but it does not clearly articulate when one should be preferred over the other. The result is that SRA and VN read as parallel options validated post hoc by which task they happen to win on, rather than as a principled, jointly-motivated design.
-
The regularization losses are assembled from established objectives, but this lacks an articulated account of how the terms interact, so it is hard to tell whether the combination reflects genuine insight or accumulated engineering. An ablation that turns off each regularization term individually to show their individual contributions and sensitivity to their weights could provide more evidence about the such combination.
-
How do the EAMS variants compare against the baselines when the baselines are given rotation augmentation during training? How does the current experiment set up ensure fair comparison?
Limitations
yes
Final justification
After carefully reading the rebuttal, I maintain my original rating.
Formatting concerns
No
1 comment
- Rating
- 5/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 4/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper covers the development of EAMS (Equivariant Anatomical Mesh Segmentor) which is building on existing work (EMNN). The method is used for the segmentation of 3D surface meshes. The approach is evaluated on various datasets covering different clinical application areas and shows good results.
Strengths and weaknesses
Strengths: The developed approach can be applied to any 3D mesh and as such might be beneficial to a wider community. The evaluation seems strong, but also identifies areas for improvement.
Weaknesses: The evaluation could have discussed in more detail where the method fails. The evaluation could have been expanded by including p-values for the differences.
Questions
It would be good to explore where the method fails in more detail.
It would be good to see p-values associated with the differences.
It would be good to explore further why some of the baseline results are stronger for the existing approaches.
It would be good to explain why some of the EAMS results are better on rotation compared to the baseline.
Limitations
Limitations are briefly discussed within the paper.
Final justification
Interesting approach which could be used widely. Evaluation good, but could be extended.
Formatting concerns
None.
2 comments
Response to Reviewer vTFs (Part 1)
Thank you for your review! We also appreciate your recognition of the problem motivation, broader applicability, and evaluation breadth across anatomical settings and supervision types. We report new experiments once in the labeled meta-response sections M1–M4 and answer your questions directly below.
1. Where does the method fail?
We analyzed held-out liver meshes, where the submission shows the clearest room for improvement, using the base EAMS and the strongest VN+EAMS variant. Across each fold, we computed Spearman correlations between per-mesh Dice and descriptors of target geometry, global shape, PCA-frame conditioning, and mesh discretization. Below we report descriptors whose association had the same sign in all folds; values are median correlations across folds. We will also add images of representative lowest-scoring cases in the revision.
EAMS — ligament Dice
| Descriptor | Median |
|---|---|
| Ligament curvature, mean | −0.556 |
| PCA eigengap 1–2 | −0.457 |
| Background curvature w/o ligament, mean | −0.393 |
| Background curvature w/o ridge, mean | −0.393 |
| Ridge curvature, mean | −0.355 |
EAMS — ridge Dice
| Descriptor | Median |
|---|---|
| Normalized edge length, mean | −0.332 |
VN+EAMS — ligament Dice
| Descriptor | Median |
|---|---|
| Ligament curvature, mean | −0.559 |
| Ridge curvature, mean | −0.430 |
| Background curvature w/o ligament, mean | −0.427 |
| Background curvature w/o ridge, mean | −0.427 |
| PCA eigengap 1–2 | −0.400 |
| PCA eigengap 2–3 | 0.347 |
| Ridge curvature contrast | −0.313 |
VN+EAMS — ridge Dice
| Descriptor | Median |
|---|---|
| PCA sign margin, axis 1 | −0.412 |
| PCA eigengap 2–3 | 0.365 |
| PCA sign margin, axis 2 | −0.358 |
| PCA eigengap 1–2 | −0.343 |
| Normalized edge length, mean | −0.301 |
The clearest shared pattern is ligament geometry: higher mean ligament curvature is associated with lower Dice for both EAMS () and VN+EAMS (). Several surrounding-curvature descriptors show the same direction, indicating that thin, highly curved ligament regions remain the principal challenge even after adding global context. By contrast, base EAMS ridge Dice has only one consistently associated descriptor; most measured descriptors have correlations near zero or signs that vary across folds. VN+EAMS ridge performance has moderate associations with global-shape and frame descriptors, but the opposite signs of the two eigengap associations do not indicate one general eigengap failure. The direct sensitivity analysis in M4 separately shows stable liver frames and predictions under the tested transformations.
2. Statistical comparisons
The paper reports mean ± SD over five held-out folds. Although formal uncertainty analysis (e.g. p-values) can complement these summaries, for the primary robustness comparisons, the differences are quite large relative to the reported fold variation. For example, under matched augmentation at 40°, the strongest IntrA baseline obtains 81.75 aneurysm Dice versus 93.59–95.81 for EAMS variants; the strongest IOSSeg baseline obtains 52.33 IoU versus 80.09 for VN+EAMS (M1). Thus the central conclusion does not depend on a marginal difference between means. If the reviewer feels this is needed for establishing specific claims, please mention it and we will prioritize it during discussion.
3. Why are existing baselines stronger in some cases?
The main case is canonical liver ligament segmentation, where MeshGraphCNN retains a substantial advantage. M2 tests the explanation directly by appending centred raw coordinates to EMNN. Making the model pose-sensitive improves liver ligament/ridge Dice by 1.96/5.49 and IOSSeg IoU by 4.79, but reduces IntrA aneurysm Dice by 5.40. Consistently aligned liver and dental datasets therefore permit models to exploit dataset-level location and orientation cues; removing those cues creates the reported canonical-accuracy/rotation-robustness trade-off. IntrA meshes have arbitrary orientation, so the same pose dependence is harmful.
Response to Reviewer vTFs (Part 2)
4. Why is EAMS stronger under rotation?
For exact EMNN features, a rigid transformation rotates vector channels while leaving scalar channels unchanged; equivariant message passing preserves these transformation types, and the scalar segmentation logits are therefore invariant. SRA preserves this property through invariant assignments and scalar region mixing, while VN exchanges equivariant messages with coordinate-bearing global tokens. Consequently, rotating the same anatomy does not require the model to relearn every pose from data.
Non-equivariant baselines can approximate this behavior through augmentation, but have no architectural guarantee outside the sampled training transformations. M1 tests this explanation under matched training: augmentation improves several baselines, yet they remain substantially less stable at 40° and under random-axis perturbations. For dental and liver EAMS, this argument additionally depends on the PCA-derived canonical features; their conditions and measured stability are reported in M4.
5. Contribution-type clarification
The reviewer selected Use-inspired, whereas we selected General. This is not a disagreement about the substance of the work, but we chose General deliberately: the paper develops and evaluates an ML method using curated research datasets and does not clinical workflow validation or domain-expert co-design. We therefore preferred not to overstate its present application readiness.
Summary. The new failure analysis identifies highly curved ligament geometry as the clearest remaining challenge; M1 establishes the rotation advantage under matched augmentation; M2 explains when canonical pose helps existing methods; and M4 separates architectural invariance from data-dependent canonicalization. We therefore ask that you maintain your accept score. If any concrete concern remains, please identify it so that we can address it during the remaining discussion period.
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 2/4
- Originality
- 2/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper proposes EAMS, an anatomical mesh segmentation framework based on Equivariant Mesh Neural Networks. The method operates directly on irregular anatomical surface meshes and combines intrinsic geometric descriptors, including HKS and dihedral features, with anatomy-aware coordinate priors where appropriate, such as PCA-derived frames for dental and liver surfaces. The authors further augment local EMNN-style message passing with soft regional aggregators and virtual nodes.
EAMS is evaluated on intracranial aneurysm segmentation, intraoral tooth segmentation, and liver surface landmark segmentation, covering vertex-, face-, and edge-level supervision. The main claim is that a lightweight equivariant mesh framework can remain competitive with task-specific non-equivariant baselines on canonical inputs while being substantially more stable under geometric perturbations.
Strengths and weaknesses
Strengths:
- The problem is well motivated, and the evaluation spans multiple anatomical settings and supervision types, making the study more informative than a single-dataset demonstration.
- The strongest robustness evidence is on IntrA and the dental datasets. On IntrA, EAMS improves over DGCNN and PTv3 while remaining exactly E(3)-invariant under the tested transformations. On the dental datasets, VN+EAMS is close to Fast-TGCN on canonical inputs, but is much more stable under rotation.
- The architecture is compact and coherent: the intrinsic features, mesh-aware message passing, and lightweight global-context modules all fit the paper’s robustness motivation.
- The liver experiments are useful because they show a real accuracy-robustness trade-off: invariance improves stability under rotation, but can also forfeit useful global orientation priors.
Major Weaknesses:
- Methodological novelty is moderate rather than strong. The paper combines several familiar components, including EMNN-style equivariant mesh processing, intrinsic geometric descriptors, PCA-derived anatomical frames, global/virtual nodes, and boundary-aware losses. The soft regional aggregator is useful, but the paper does not clearly establish a new equivariant mechanism, objective, theory, or general architectural principle beyond this integration. For a General NeurIPS submission, the authors should clarify whether the main contribution is a new method, an empirical robustness study, or a systematization of equivariant anatomical mesh segmentation. A targeted ablation showing that SRA/VN modules add value beyond EMNN plus strong features would make the novelty claim more convincing.
- Robustness comparisons leave an important uncertainty about the non-equivariant baselines. The paper’s strongest empirical advantage comes from test-time rotations and reflections. The manuscript shows that standard baselines are brittle under this protocol, but it is not clear whether they were trained with strong rotation augmentation, canonical-frame preprocessing, test-time augmentation, or other robustness-oriented procedures. I do not treat this as a proven flaw, but it matters for interpreting the results. If simple augmentation, canonicalization, or test-time rotation averaging substantially improves DGCNN, PTv3, Fast-TGCN, or MeshGraphCNN, then the advantage of EAMS would be less decisive. Robustness-tuned baselines, or comparison to another equivariant geometric model, would make the central claim stronger.
- Liver segmentation reveals a substantial accuracy-robustness trade-off. On liver segmentation, EAMS variants are stable under rotation but much weaker than the best baseline on unperturbed ligament Dice. This suggests that global orientation is not merely a nuisance variable for this task; it may carry useful anatomical information. The paper acknowledges this issue, but should make it more visible when presenting the broader robustness claim. A hybrid pose-aware/equivariant model, or a clearer analysis of when invariance helps versus hurts, would make the paper stronger.
- The invariance framing should be clearer. For the dental and liver tasks, the paper uses PCA-derived anatomical frames with dataset-specific sign-resolution heuristics, so the resulting features are only approximately SE(3)-invariant. This is not necessarily a flaw, but the claims should be separated more carefully: IntrA supports exact E(3)-invariant behavior under the tested transformations, whereas the dental and liver results are better described as robustness obtained through approximate canonicalization. A sensitivity analysis for PCA sign ambiguity, near-symmetric anatomy, abnormal teeth, or unusual liver geometry would help clarify how much robustness comes from formal symmetry versus heuristic frame construction.
- The ablations are helpful but do not fully isolate the sources of the gains. The paper includes useful ablations for global node removal, dihedrals/HKS, SRA geometry, token counts, and liver frame/continuity loss. However, the full model has many interacting components, including HKS, dihedrals, PCA frames, global/virtual nodes, boundary losses, continuity loss, augmentation, and dataset-specific preprocessing. The current ablations therefore do not fully isolate which components drive the gains across datasets. A compact factorial ablation across at least IntrA and one dental dataset would help, for example: base EMNN, +HKS/dihedral, +PCA frame where applicable, +boundary losses, +global node, and +SRA or VN.
Minor Weaknesses:
- The perturbation protocol is useful as a stress test, but the paper should clarify how well synthetic rotations reflect realistic acquisition-domain shift.
- Reproducibility is reasonable but not complete: the paper gives useful experimental details, but code is not released at submission time, and exact reproduction may depend on nontrivial preprocessing, spectral caching, PCA-frame construction, label conversion, and baseline reproduction.
Questions
- Were the non-equivariant baselines trained with strong rotation augmentation, canonical-frame preprocessing, test-time augmentation, or rotation averaging? If robustness-tuned baselines still underperform EAMS, the central robustness claim would be more convincing.
- For the dental and liver tasks, how stable are the PCA-derived anatomical frames under sign ambiguity, near-symmetric anatomy, abnormal teeth, or unusual liver geometry? A small sensitivity analysis would help clarify how much robustness comes from formal invariance versus approximate canonicalization.
- For liver segmentation, can the authors clarify when global orientation should be treated as a nuisance variable and when it is an anatomically meaningful prior? The current results suggest that invariance improves rotation stability but can hurt canonical-pose ligament accuracy.
- Can the authors provide a clearer ablation separating the contributions of equivariance, HKS/dihedral features, PCA frames, boundary losses, global nodes, and SRA/VN modules? A compact factorial ablation on IntrA and one dental dataset would be sufficient.
- Will code, preprocessing scripts, split definitions, and baseline configurations be released? Exact reproduction may depend on mesh preprocessing, spectral caching, PCA-frame construction, label conversion, and baseline implementation details.
Limitations
The authors address limitations reasonably well, especially the approximate nature of the PCA-derived anatomical frames, the runtime overhead of augmented modules, and the liver accuracy-robustness trade-off.
The main remaining limitations are that the robustness claims rely heavily on synthetic rotations/reflections, the fairness of robustness-tuned non-equivariant baselines is not fully clear, and the dental/liver PCA-frame construction may be sensitive to sign ambiguity or unusual anatomy. Reproducibility is also reasonable but not complete because code is not released at submission time and exact replication may depend on nontrivial preprocessing, spectral caching, PCA-frame construction, label conversion, and baseline implementation details.
Final justification
The rebuttal addresses my main concern about the fairness of the robustness comparisons, and the matched rotation augmentation results suggest that the EAMS robustness advantage remains. The additional analyses also address several of my secondary concerns, although the methodological novelty is still moderate and the PCA-derived frames are only approximately invariant. I therefore increase my rating from 3 to 4.
Formatting concerns
No major formatting or anonymity concerns observed.
1 comment
Response to Reviewer SncY
Thank you for your review! We also appreciate you recognizing the well-motivated problem, breadth across anatomical settings and supervision types, and positive robustness results. We report the new experiments once in the labeled meta-response sections M1–M4 and answer your questions directly below.
1. Were baselines given comparable orientation treatment?
The submission retained each reproduced baseline's native training pipeline, whereas EAMS used the bounded Fast-TGCN-style rotations in Appendix C. The augmentation policy was therefore not standardized or documented clearly enough.
We have now retrained every reported non-equivariant baseline with the same rotations, splits, and model-selection protocol as EAMS (M1). Matched augmentation improves several baseline results, but the central comparison remains: at 40°, the strongest augmented baselines remain substantially below EAMS on IntrA, 3D-IOSSeg, and both liver targets. Thus the reported stability is not explained by unequal rotation augmentation. We report only the primary overlap metric in M1 to save space; all other metrics have been computed and will be included in the revised manuscript.
2. How stable are the PCA-derived frames?
We clarify the PCA equivariance claims at the start of M4 before proceeding with a sensitivity analysis.
The liver frame is stable across the tested transformations: median and 90th-percentile label-flip rates are both zero, with probability drift . The dental frame is stable in the median case, while its upper-tail variation is traced to one specific unresolved sign choice. We will state this ambiguity and the conditions on the PCA claim explicitly in revisions.
3. When is orientation nuisance variation versus useful anatomy?
The raw-coordinate diagnostic in M2 makes EMNN orientation-sensitive. It improves liver ridge Dice by 5.49 and 3D-IOSSeg IoU by 4.79, but reduces IntrA aneurysm Dice by 5.40. This matches the dataset conventions: liver and dental meshes are consistently aligned, allowing location priors to be exploited; IntrA orientation is arbitrary, making the same dependence harmful.
We will therefore distinguish arbitrary coordinate pose from consistent dataset alignment. The result also motivates hybrid pose-aware/equivariant models, but implementing and evaluating such a model properly is beyond the scope of this submission.
4. Can the gains be isolated more clearly?
Yes. Submitted Table 4 isolates HKS and dihedral features; M3 isolates SRA/VN using a common task-specific base and a parameter-matched wider EMNN. For IntrA, this base includes the global node; for 3D-IOSSeg, it includes the global node and PCA features.
The wider 160-dim control does not reproduce the gains. Full VN improves the base from 92.36 to 94.51 IntrA Dice and from 76.76 to 81.74 3D-IOSSeg IoU. SRA likewise improves both tasks, but the effect of its auxiliary loss is task-dependent. The results show that the VN gains are not explained by parameter count and clarify the distinct empirical behavior of the two global-context mechanisms.
5. Novelty and significance
The contribution is indeed not a new group-equivariant model or primitive. It centers on the study of structured multi-token global context beyond EMNN's shared global node, together with a controlled study of how intrinsic geometry, anatomical features, and pose priors interact across four benchmarks of vertex-, face-, and edge-level supervision. The orientation-matched experiments strengthen the central practical conclusion: equivariance is especially valuable when orientation is uncontrolled, while consistent alignment (teeth and liver) can supply useful pose information.
6. Robustness scope and reproducibility
The additional random-axis evaluation in M1 broadens the tested transformations beyond fixed z-rotations. We will more explicitly describe these synthetic transformations as coordinate-frame stress tests, without overclaiming closeness to acquisition-domain shifts.
Due to concurrent extensions in development, the codebase is currently not in a state fit for release. With the camera-ready paper, we will release training code on GitHub, which includes mesh preprocessing and label conversion; HKS-cache generation; PCA-frame construction. We also include split definitions and example configurations in the repo.
Summary. The matched-baseline evaluation directly resolves the principal fairness concern, while M2–M4 answer the requested questions about pose, component isolation, and PCA stability. In light of these clarifications, would you consider increasing your score for our paper? If any concrete concern still prevents an increased score, please identify it so that we may address it during the remaining discussion period.
Comments on the paper
3 comments
Meta-response (Part 1)
The meta-review identifies orientation-matched baseline evaluation as the principal issue. We therefore report that evaluation first, followed by targeted analyses requested across the reviews. Reviewer responses refer to the labels M1–M4 below to avoid repeating results.
M1 — Orientation-matched baselines
Clarification. In the submission, each reproduced baseline retained its native training pipeline, whereas EAMS used the bounded Fast-TGCN-style rotations in Appendix C. All methods used identical splits and compatible mesh preprocessing, but orientation augmentation was not standardized or documented clearly enough.
We retrained every reported non-equivariant baseline with the same stochastic rotations as EAMS: angles sampled uniformly from , using the same splits and model-selection protocol. Translation augmentation is unnecessary because every mesh is centered deterministically.
We additionally include a random axis-angle test which samples an axis uniformly on the sphere and an angle uniformly from . This represents a broadening of the bounded stress test, not necessarily an estimate of a clinical distribution. Reflections are used only as a coordinate-handedness test for IntrA.
For concision, we report the primary overlap metric here: Dice for liver/IntrA and the manuscript's average IoU for IOSSeg. The other reported metrics have been computed and will be included in the revised manuscript.Results are mean ± SD across five folds.
Liver: Dice (%)
| Model | Target | Canonical | Z-15° | Z-40° | Random axis |
|---|---|---|---|---|---|
| PointNet++ | Ligament | 36.18±2.54 | 25.60±3.90 | 11.79±2.21 | 20.36±2.45 |
| Ridge | 59.19±0.74 | 58.70±1.81 | 47.89±1.26 | 51.03±1.45 | |
| DGCNN | Ligament | 33.12±2.78 | 26.68±2.85 | 7.47±0.89 | 20.27±2.37 |
| Ridge | 58.20±2.60 | 57.79±1.80 | 42.42±0.59 | 46.80±3.74 | |
| MeshGraphCNN | Ligament | 44.13±0.94 | 29.50±0.62 | 6.21±0.44 | 21.94±0.71 |
| Ridge | 59.87±0.24 | 55.13±0.36 | 40.08±0.16 | 41.89±0.17 |
Matched augmentation improves several perturbed scores but does not close the robustness gap: at 40°, the strongest baselines obtain 11.79 ligament and 47.89 ridge Dice, versus 26.33 and 58.51 for the corresponding EAMS variants in submitted Table 3. MeshGraphCNN remains stronger on canonical ligament Dice (44.13 versus 26.33), confirming the reported accuracy–robustness trade-off.
IntrA: Dice (%)
| Model | Target | Canonical | Z-15° | Z-40° | Reflection | Random axis |
|---|---|---|---|---|---|---|
| DGCNN | Aneurysm | 88.17±1.69 | 87.45±1.71 | 81.75±0.40 | 81.28±2.76 | 79.62±1.30 |
| Parent | 97.16±0.59 | 96.91±0.64 | 95.65±0.19 | 95.85±0.34 | 95.21±0.19 | |
| PTv3 | Aneurysm | 81.29±5.28 | 80.36±4.96 | 77.24±4.26 | 74.70±4.44 | 76.93±4.80 |
| Parent | 95.28±1.38 | 95.11±1.25 | 94.31±1.05 | 93.67±0.87 | 94.03±1.04 |
Augmented DGCNN improves over submitted Table 1, but its strongest 40° aneurysm result is 81.75 Dice, versus 93.59–95.81 for EAMS variants. The central IntrA result therefore holds under identical orientation augmentation.
3D-IOSSeg: average IoU (%)
| Model | Canonical | Z-15° | Z-40° | Random axis |
|---|---|---|---|---|
| DGCNN | 65.92±0.92 | 58.08±0.72 | 37.92±0.49 | 28.18±0.33 |
| PTv3 | 80.45±0.40 | 77.61±0.32 | 50.16±2.39 | 45.05±0.65 |
| Fast-TGCN | 81.05±0.74 | 76.45±1.14 | 52.33±1.62 | 45.59±1.12 |
PTv3 benefits substantially at 40°; Fast-TGCN is unchanged because this was already its native augmentation. The strongest baseline nevertheless falls from 81.05 canonical IoU to 52.33 at 40°, whereas VN+EAMS changes from 79.74 to 80.09 in submitted Table 2.
M2 — Pose information
We append centered raw coordinates to EMNN's scalar node features, deliberately making the predictor pose-sensitive:
| Dataset / metric | Target | EMNN | + raw XYZ | Δ |
|---|---|---|---|---|
| Liver Dice | Ligament | 19.33 | 21.29 | +1.96 |
| Ridge | 55.39 | 60.88 | +5.49 | |
| IntrA Dice | Parent | 96.43 | 94.57 | −1.86 |
| Aneurysm | 88.28 | 82.88 | −5.40 | |
| 3D-IOSSeg IoU | Average | 71.15 | 75.94 | +4.79 |
This diagnostic shows that pose-dependent coordinates can be exploited on canonically aligned liver and dental data, while the same dependence harms arbitrarily oriented IntrA. It supports the interpretation that the appropriate symmetry depends on the acquisition regime. We will distinguish arbitrary coordinate pose from consistent dataset alignment and discuss hybrid pose-aware/equivariant models as a natural extension. This targeted diagnostic was conducted on one fold.
Meta-response (Part 2)
M3 — Global-context ablations
We compare SRA/VN variants against the same task-specific EAMS base and a width-160, parameter-matched EMNN. For IntrA, the base adds the global node; for 3D-IOSSeg, it adds the global node and PCA features. Submitted Table 4 separately ablates HKS and dihedral features.
| Variant | IntrA Dice | IntrA IoU | 3D-IOSSeg IoU |
|---|---|---|---|
| EMNN, no boundary loss | 91.03 | 85.22 | 29.97 |
| + boundary-aware loss | 91.56 | 85.81 | 32.50 |
| Task-specific EAMS base | 92.36 | 86.92 | 71.64 |
| Base + SRA, no SRA regularization | 93.79 | 89.33 | 74.49 |
| Base + full SRA | 92.97 | 88.19 | 75.61 |
| Base + VN, no VN regularization | 93.39 | 90.16 | 80.65 |
| Base + full VN | 94.51 | 91.28 | 81.74 |
| Parameter-matched width-160 EMNN | 90.40 | 84.31 | 72.22 |
The capacity control does not reproduce the gains. VN improves both task-specific bases, including without its auxiliary loss, and the full VN loss improves further. SRA likewise improves both tasks, but the effect of its auxiliary loss is task-dependent. These targeted ablations were conducted on one fold.
M4 — PCA-frame stability and wording
Clarifying the "approximate" invariance. For centred coordinates with covariance C, a rotation R gives . With distinct eigenvalues and fixed ordering, PCA eigenvectors transform as , up to independent signs; repeated or near-repeated eigenvalues also permit rotations within an eigenspace. Thus, we emphasize that PCA supplies an E(3)-equivariant set of candidate frames, while a unique invariant coordinate system additionally requires consistent sign selection; this latter requirement is the source of the "approximation". We will further highlight these conditions in Appendix B.
We tested 16 random-axis rotations per held-out mesh, recomputed each frame, and measured maximum absolute input-feature drift, predicted-label flip fraction, and maximum class-probability drift. Values are median / 90th percentile across mesh–rotation trials:
| Dataset | Feature drift | Prediction flips | Probability drift |
|---|---|---|---|
| Liver | 1.33e−6 / 7.70e−6 | 0 / 0 | 2.35e−6 / 2.47e−4 |
| 3D-IOSSeg | 3.05e−5 / 54.3 | 0 / 0.133 | 3.60e−5 / 0.998 |
The liver construction resolves two axis signs using weighted asymmetry and deterministic fallbacks, then derives the third by a cross product, producing stable results on the evaluated data. The dental construction resolves the anterior–posterior axis (in our case, the -axis) from dental arch concavity and enforces right-handedness, but, as we found out performing this analysis, does not distinguish the simultaneous choice. This explains the observed upper-tail variation; the median feature and prediction behavior remains stable. We will state the remaining sign ambiguity explicitly and provide this explanation in the revisions.
Together, M1–M4 directly address the fairness, isolation, and invariance questions raised in the reviews while preserving the main empirical conclusion: under matched training treatment, EAMS remains substantially more stable to orientation changes.
Discussion
As we enter the final discussion period, would the reviewers please take a look at our responses and consider updating their scores if their feedback has been adequately addressed?
Thanks!
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Response to Reviewer TBA9
Thank you for your review! We also appreciate your recognition of the problem motivation, exposition, parameter efficiency, and evaluation across anatomical settings and supervision types. We report new experiments once in the labeled meta-response sections M1–M4 and answer your questions directly below.
1. Novelty and contribution
The contribution is not a new group-equivariant architecture or primitive. EAMS develops and evaluates a lightweight design for anatomical mesh segmentation: it augments EMNN's shared global node with two multi-token global-context mechanisms, integrates intrinsic and anatomy-aware features while preserving the relevant group action, and tests these choices across four benchmarks with vertex-, face-, and edge-level supervision.
The study also exposes a central tension: arbitrary coordinate pose should be removed, yet consistent dataset alignment can encode useful anatomical cues. M2 shows that pose-sensitive coordinates help aligned liver and dental data but harm arbitrarily oriented IntrA.
2. Rationale and gains of SRA/VN
Both modules address the limitation of EMNN's few-hop receptive field without substantially deepening the network, but impose different inductive biases:
The common-base and parameter-matched ablation in M3 clarifies the gains and selection rule. Without auxiliary regularization, both modules improve the task-specific base on IntrA and IOSSeg; the width-160 parameter-matched EMNN does not, ruling out added capacity as the explanation. VN performs best overall and is our evidence-backed default; SRA is a competitive structured alternative when regional compression is preferred. Full VN improves every reported metric over unregularized VN, whereas SRA regularization is task-dependent, although both SRA variants exceed the base on both tasks. We will narrow the claim accordingly: VN regularization is consistently helpful here, while SRA regularization should be selected by validation.
3. Rotation-augmented baselines and fairness
The submission retained each reproduced baseline's native training pipeline, while EAMS used the bounded Fast-TGCN-style rotations in Appendix C; this orientation treatment was not standardized or documented clearly enough.
We have now retrained every reported non-equivariant baseline with the same rotations, splits, preprocessing, and model-selection protocol as EAMS (M1). Augmentation improves several baseline results, but does not explain the robustness gap: at 40°, the strongest augmented baseline remains substantially below EAMS on IntrA, 3D-IOSSeg, and both liver targets. We report only the primary overlap metric in M1 to conserve characters; all secondary metrics have been computed and will be included in the revision.
4. Clinical significance
The synthetic transformations are controlled coordinate-frame stress tests, not estimates of how often a specific perturbation occurs clinically. Their purpose is to test dependence on an arbitrary representation choice under identical anatomy. M1 broadens the original fixed-axis tests with random axes and larger angles, showing that matched augmentation does not close the gap. Meanwhile, M2 shows why canonical-pose performance may also be useful. We will highlight this scope explicitly and frame the result as robustness to coordinate-pose variation.
5. Reproducibility
The main text presents the design and principal protocol; the appendices provide the full algorithms, preprocessing, feature construction, loss weights, and some model configurations, as necessitated by the page limit. Anyways, with the camera-ready paper, we will release the training code and configurations, including mesh preprocessing and label conversion, HKS-cache generation, PCA-frame construction, and split definitions.
Summary. M1 resolves the fairness question with orientation-matched baselines; M2 clarifies when pose is nuisance variation or useful context; and M3 isolates the global-context modules from parameter count and auxiliary regularization. In light of these clarifications, would you consider increasing your score for our paper? If any concrete concern still prevents an increased score, please identify it so that we may address it during the remaining discussion period.