potentialpaper

Knowledge Transfer Scaling Laws for 3D Medical Imaging

Ho Hin Lee, Dongna Du, Chu Wang, Yuankai Huo, Shi Gu, James Gee, Yifan Wu

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

TL;DR. We develop a transfer-aware scaling law that jointly models heterogeneous domain exponents and asymmetric cross-domain transfer to optimize data mixtures for 3D medical foundation model pre-training.

Abstract. Vision foundation models are increasingly moving beyond 2D to volumetric domains such as 3D medical imaging, where unified pretraining across different imaging modalities (i.e. CT, MRI, and PET) could provide foundational models for diverse clinical tasks. However, training such models requires mixing heterogeneous imaging domains, and current mixture strategies remain largely heuristic. In this work, we observe that different medical imaging domains scale at variable rates during pretraining, and knowledge transfer between domains is strongly asymmetric: training on one domain can substantially improve another, but the reverse may be much weaker. Interestingly, both MAE reconstruction loss and cross-domain transfer follow predictable power-law trends with domain-specific behaviors. Motivated by these findings, we formulate data allocation as a scaling-law optimization problem. The derived allocations reveal an interpretable hub-and-island structure: highly transferable domains emerge as hubs that benefit many others and deserve strategic allocation, while isolated domains act as islands requiring direct investment. Empirically, transfer-aware allocation outperforms data-proportional sampling by up to 58% and generalizes well to unseen budgets with r=0.989. Downstream validation on disease classification and organ/lesion segmentation further confirms that the derived transfer-aware mixtures provide stronger pretrained representations for clinical 3D medical imaging tasks.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
1 May 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 4 reviews · OpenReview

Updated 25 Nov 2026, 03:48 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

This paper studies the problem of data mixture optimization for medical imaging, where data is drawn from different medical image modalities (CT, MRI, and PET). The paper introduces a mixture-based scaling law and a corresponding optimization problem that minimizes MAE reconstruction error.

Initial reviews of this paper are borderline. I recommend the authors to review and address all comments. I note two key comments observed by multiple reviewers below:

  • MAE as the loss to minimize may be limited both for downstream tasks dealing with medical imaging and with the diversity of modalities. How is the framework robust to alternative losses and are the current optimal data mixtures effective on downstream settings?
  • The paper includes some discussion in related literature corresponding to other mixture optimization algorithms. How does the method sufficiently differentiate itself or compare empirically against these alternatives? Here, I note that while RegMix is mentioned, it is one among a rapidly growing literature.
Final justification

Thanks to the authors for a thorough rebuttal. All reviewers recommend acceptance noting that the rebuttal has addressed most of the initially raised concerns. I recommend the authors to incorporate the new analysis and discussions into the final version of the paper. Moreover, Reviewer foD1's initial review included a request for differentiation of hte work with Transfusion (Raghu et al). While the rebuttal includes some discussion, I strongly urge the authors to expand on this clarification further in their revision.

Area Chair 7app · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

This paper studies the problem of data mixture optimization for medical imaging, where data is drawn from different medical image modalities (CT, MRI, and PET). The paper introduces a mixture-based scaling law and a corresponding optimization problem that minimizes MAE reconstruction error.

Initial reviews of this paper are borderline. I recommend the authors to review and address all comments. I note two key comments observed by multiple reviewers below:

  • MAE as the loss to minimize may be limited both for downstream tasks dealing with medical imaging and with the diversity of modalities. How is the framework robust to alternative losses and are the current optimal data mixtures effective on downstream settings?
  • The paper includes some discussion in related literature corresponding to other mixture optimization algorithms. How does the method sufficiently differentiate itself or compare empirically against these alternatives? Here, I note that while RegMix is mentioned, it is one among a rapidly growing literature.
Final justification

Thanks to the authors for a thorough rebuttal. All reviewers recommend acceptance noting that the rebuttal has addressed most of the initially raised concerns. I recommend the authors to incorporate the new analysis and discussions into the final version of the paper. Moreover, Reviewer foD1's initial review included a request for differentiation of hte work with Transfusion (Raghu et al). While the rebuttal includes some discussion, I strongly urge the authors to expand on this clarification further in their revision.

1 comment
Authors · CommentOpenReview ↗

Summary of What We have Addressed

We thank the meta-reviewer and all reviewers for their careful and constructive assessment. Across the reviews, the paper was recognized as addressing an important and timely problem in heterogeneous medical-image pretraining. Reviewers highlighted the simplicity and interpretability of the formulation, the directional transfer matrix and intuitive hub-and-island structure, the clear presentation, and the promising gains across budgets and downstream tasks. We also appreciate that the initial assessments identified important limitations requiring stronger evidence. We address the two recurring concerns below and summarize the new experiments.

1. Robustness of the MAE objective and downstream effectiveness

This concern is addressed in R2-W2/Q2, R2-W4/Q1/Q3, and R4-W1.

For cross-modality robustness, CT, MRI, and PET inputs are modality-specifically preprocessed and normalized to [−1,1][-1,1] before MAE is computed. We further re-optimized the 100K mixture using dimensionless target-wise losses normalized by either each target's best single-domain reference or its Uniform-mixture loss. The resulting allocations remain close to the original solution (cosine similarity 0.930.93--0.970.97) and preserve the same hub-and-island structure. Thus, the allocation is not driven by one modality having a larger absolute MAE scale.

For downstream effectiveness, we expanded the comparison to Uniform, Data-Proportional, Transfer-Naïve, Data Mixing Laws, RegMix, and Transfer-Aware. Transfer-Aware achieves the highest Dice on all six segmentation tasks, averaging +1.57+1.57 Dice over RegMix, and the highest mean classification accuracy (79.4%79.4\% vs. 78.3%78.3\%). Across strategies with matched 100K reconstruction losses, MAE correlates with mean Dice at ρ=−0.82\rho=-0.82 and mean classification accuracy at ρ=−0.60\rho=-0.60. These results support MAE as a useful mixture-selection proxy, particularly for dense prediction, while showing that it does not perfectly predict every downstream metric.

The framework is not mathematically restricted to MAE: another scalar per-domain validation objective (i.e. contrastive loss, Dino loss) can replace LiL_i after refitting the corresponding scaling and transfer parameters. However, the parameters and optimal mixture are objective-specific. We therefore now describe MAE as a validated proxy in the evaluated setting, not as a universal measure of medical representation quality, and explicitly list robustness across alternative self-supervised objectives as future work.

2. Differentiation from alternative mixture-optimization methods

This concern is addressed in R2-W3/Q7 and R4-W2. We expanded both the related-work discussion and empirical evaluation beyond heuristic mixtures by adding RegMix and Data Mixing Laws.

RegMix learns a flexible black-box mapping from mixture weights to validation loss, while Data Mixing Laws models mixture and data-scale effects. Our method instead separates target-specific scaling, βi\beta_i, from directed source-to-target transfer, τij\tau_{ij}. This yields budget-dependent allocations and an interpretable transfer matrix that identifies transferable hubs and domains requiring direct investment.

Empirically, Transfer-Aware is 14.3% lower than RegMix at 10K and 19.5% lower at 100K; RegMix is 3.3% lower at 50K, and the methods are effectively tied at 200K. Transfer-Aware also outperforms RegMix and Data Mixing Laws on all six segmentation tasks, while RegMix remains competitive on classification. We therefore do not claim uniform dominance.

We also clarify the distinction from temperature sampling and DoReMi. DoReMi performs online group-robust reweighting and changes the training objective, whereas the evaluated baselines select fixed mixtures under the same pretraining objective and budget. We therefore view DoReMi-style adaptive training as complementary and explicitly acknowledge that our experiments do not exhaust the rapidly growing mixture-optimization literature.

Overall Summary

Overall, the rebuttal strengthens the paper along both dimensions emphasized by the meta-reviewer. It shows that the allocation structure is robust to cross-modality loss normalization and that the selected mixture transfers consistently to supervised medical tasks. It also adds stronger learned and scaling-law baselines while clarifying the method's distinct contribution: an interpretable, directional transfer model for budget-dependent mixture design. We have narrowed the claims accordingly: the contribution is a transfer-aware mixture-optimization framework validated in a controlled six-domain 3D setting, rather than a universal objective or exhaustive solution to medical-data mixture optimization.

Reviewer KViROpenReview ↗
Rating
4/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper studies the mixture strategies optimization for different domain images (CT, MRI, and PET). They use MAE reconstruction loss to show that power-law scaling of different domains are different, and the cross-domain transfer is asymmetric. They show that, for different domains, the gain of more data is different and the information that can be transferred to other domain is also different. The extracted scaling law can be used to direct data allocation in large scale.

Strengths and weaknesses

Strengths:

  1. The motivation of this paper is good.
  2. Modeling both domain-specific scaling behavior and asymmetric cross-domain transfer is intuitive.
  3. The final allocation improves MAE loss across budgets and domains, and also improves downstream classification and segmentation after fine-tuning, indicating the effectiveness and generalizability of the proposed method.

Weaknesses:

  1. The scaling law is built on the MAE reconstruction loss, which is a proxy of knowledge transfer, not a semantic/clinical knowledge transfer. MAE loss itself is problematic when used for medical image. Because a model may reconstruct target-domain images refering to MAE well because it learned: low-level intensity statistics, texture, and easy background/foreground patterns. However, this does not guarantee the model learned clinically useful features (e.g. small lesions, abnormality recognition, and disease-relevant representations). These details can be critical for downstream medical task.
  2. The related work mentions RegMix. But experimentally, they do not seem to compare against adapted versions of this method. For example, RegMix treats data mixture selection as a regression problem: train many small proxy models on different mixtures, record performance, fit a regression model to predict performance for unseen mixtures, then choose the best predicted mixture for large-scale training. I think RegMix can be adapted to this paper easily.
  3. The foundation training is usually on large-scale dataset. But their method performance is best when the budget is 50K scale, and the improvement on 200K scale is very limited. This makes me suspect the meaningful of this method in very large scale training.
Questions

Given that the 200K gains nearly vanish, what's the argument that transfer-aware allocation still matters at the scales practitioners actually pretrain unified models at?

Limitations

The improvement on 200K is limited.

Final justification

I am satisfied with the rebuttal. I insist on my positive review.

Formatting concerns

"AdamW [?]" in A.4 (line 551).

3 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We thank the reviewer for the positive and constructive assessment and for viewing the paper as a borderline accept. We appreciate the reviewer’s recognition of the importance of transfer-aware data allocation for heterogeneous 3D medical pretraining and of the potential value of the proposed scaling-law framework. The remaining concerns focus on three important questions: whether MAE is an appropriate proxy for clinically useful representation learning, how our approach compares with learned mixture optimization such as RegMix, and whether the benefit remains practically relevant as the pretraining budget increases. We address each point below with additional analyses, experiments, and corresponding manuscript revisions.

W1. MAE is a proxy rather than a direct measure of clinical knowledge

We agree that low MAE reconstruction loss alone does not establish semantic or clinical knowledge. A model may reduce reconstruction error by learning intensity distributions, texture, or background-foreground structure without necessarily capturing small lesions or disease-relevant abnormalities. We will therefore revise the manuscript to describe MAE explicitly as a controlled proxy for selecting the pretraining mixture, rather than as a direct measure of clinical validity.

In parallel, we also evaluate whether this proxy transfers beyond reconstruction through downstream tasks that require clinically relevant representations. The MAE-derived Transfer-Aware mixture achieves the strongest results across three classification benchmarks and six organ or lesion segmentation benchmarks spanning CT, MRI, and PET. In particular, it improves over Data-Proportional pretraining on all six segmentation tasks, including brain tumors, head-and-neck tumors, and brain hemorrhage, with p<0.01p<0.01. Because these tasks require abnormality recognition and spatially accurate delineation of pathological regions, the results provide task-specific evidence that the learned representations capture information beyond low-level reconstruction statistics.

We do not claim that MAE is universally optimal or that these results establish full clinical validity. Rather, the downstream results show that MAE provides a useful mixture-selection proxy to extract clinical-meaningful representation which can be transfered to enhance diverse downstream clinical tasks. We will make this scope and limitation explicit in the revision.

W2. Comparison with RegMix

We agree that RegMix can be naturally adapted to our setting. We therefore implemented a RegMix-style baseline using anchored and Dirichlet-sampled mixtures under the same 5%5\% minimum-allocation constraint. Each mixture uses the same 3D MAE proxy model and is evaluated on all six target domains. We fit one LightGBM regressor per target domain, average the six predicted losses, and search the predicted mixture landscape to obtain the RegMix allocation.

Mean reconstruction MAE across six domains (↓\downarrow):

Pretraining mixture 10K 50K 100K 200K
Uniform 0.0853 0.0671 0.0345 0.0228
Data-Proportional 0.0843 0.0712 0.0365 0.0233
Transfer-Naïve 0.0835 0.0799 0.0399 0.0283
RegMix 0.0935 0.0437 0.0328 0.0224
Transfer-Aware (Ours) 0.0801 0.04510 0.0264 0.0224

The comparison is budget-dependent. Transfer-Aware reduces mean MAE relative to RegMix by 14.3%14.3\% at 10K and 19.5%19.5\% at 100K. RegMix is slightly better at 50K by 3.3%3.3\%, while the two methods are effectively tied at 200K.

More broadly, the gaps among Transfer-Aware, RegMix, Uniform, and Data-Proportional become small at 200K, suggesting that the strongest strategies are approaching an irreducible-loss or capacity-limited regime in which mixture selection has less influence. We therefore use the 100K budget for downstream evaluation: it remains within the data-limited regime, exhibits clear separation among mixture strategies, and allows the effect of allocation quality on learned representations to be evaluated before performance becomes obscured by near-saturation.

Pretraining mixture OASIS-1 SynBrain-PET OrganMNIST3D AMOS-CT AMOS-MRI BraTS-T1 BraTS-T2 HECKTOR BHSD
RegMix 68.8 (79.7) 74.6 (95.3) 91.5 (99.5) 82.5 (running) 53.0 63.1 69.3 59.3
Transfer-Aware (Ours) 69.7 (78.4)∗^{*} 78.1 (95.9)∗^{*} 90.3 (99.4) 83.1∗^{*} 69.4 55.1∗^{*} 65.4∗^{*} 71.1∗^{*} 61.2∗^{*}
  • Downstream performance at T=100T=100K. Classification reports Accuracy (AUC) in %; segmentation reports Dice in %. ∗^{*} denotes p<0.01p<0.01 against Data-Proportional pretraining under a paired Wilcoxon signed-rank test. (Will update the running experiment results due to limited time)

At the 100K budget used for downstream evaluation, Transfer-Aware outperforms RegMix on all five segmentation tasks for which RegMix results are available, with gains ranging from +0.5+0.5 to +2.3+2.3 Dice and an average improvement of +1.7+1.7 Dice. The gains are particularly clear on AMOS-CT (82.582.5 vs. 83.183.1), BraTS-T1 (55.155.1 vs. 53.053.0), BraTS-T2 (65.465.4 vs. 63.163.1), HECKTOR (71.171.1 vs. 69.369.3), and BHSD (61.261.2 vs. 59.359.3). On classification, Transfer-Aware achieves higher accuracy on OASIS-1 and SynBrain-PET, whereas RegMix performs better on OrganMNIST3D and obtains a higher OASIS-1 AUC. Thus, RegMix remains competitive on classification, while Transfer-Aware shows more consistent improvements on dense organ and lesion segmentation.

The two methods make complementary modeling trade-offs:

Aspect RegMix Transfer-Aware
Modeling approach Learns a flexible mixture-to-loss regression Separates domain scaling and directed transfer through βi\beta_i and τij\tau_{ij}
Primary strength Can capture nonlinear interactions among mixture components Provides budget-dependent and interpretable source-to-target transfer
Interpretation Identifies which mixture is predicted to work well Explains why domains receive allocation through hub, island, and effective-budget structure
Limitation Cross-domain transfer relationships remain implicit Additive effective-budget model may miss nonlinear synergy or interference
Observed results Better at 50K and on selected classification metrics Better at 10K and 100K, and consistently stronger on available segmentation tasks

Thus, our contribution is not simply another predictor of the optimal mixture. RegMix learns the correspondence between mixture weights and loss, whereas our framework provides a structured model of how knowledge transfers directionally among heterogeneous 3D CT, MRI, and PET domains. It yields reusable, budget-dependent allocations h∗(T)\mathbf h^{*}(T) and explains which domains act as transfer hubs and which require direct investment as islands. We view this interpretability and the consistent dense-prediction improvements as the main advantages of our approach, while recognizing RegMix’s greater flexibility in modeling nonlinear mixture interactions. It will be a great extension or become our next step to integrate the transfer knowledge modeling into Regmix-like approach and modeling the non-linear interaction with the cross-domain knowledge between 3D medical imaging.

W3. Relevance to large-scale foundation-model training

We agree that the reduced separation at 200K requires clarification. The observed saturation is specific to the relatively small, fixed-capacity proxy model used for mixture estimation; it should not be interpreted as a universal performance ceiling for larger foundation models.

Our intended workflow is to use a small proxy model to efficiently estimate the relative scaling behavior and directed transfer among the available 3D imaging domains before committing compute to full-scale pretraining. At the current six-domain data scale, this proxy is sufficient to recover a meaningful mixture: Transfer-Aware provides clear reconstruction-loss improvements at 100K, and the resulting encoder consistently improves downstream segmentation over RegMix. The purpose of the proxy is therefore to identify useful allocation structure, rather than to reproduce the ultimate loss floor of the final foundation model.

The narrowing gaps at 200K indicate that the current proxy model is approaching its capacity-limited floor. When model capacity is increased, this floor and the allocation-sensitive data regime are expected to shift, which motivates scaling the data population together with model size, as also practiced in recent large-scale vision foundation models such as DINOv3 and Perception Encoder [7,8]. A larger model may therefore continue to benefit from additional data after the smaller proxy has saturated.

We nevertheless do not assume that the exact fitted parameters or mixture remain invariant across model sizes. Model scaling may change EiE_i, βi\beta_i, and potentially τij\tau_{ij}. Our present results establish that small proxy models can provide useful mixture guidance within the evaluated regime; jointly modeling model size, data budget, and mixture through L(N,h,T)L(N,\mathbf h,T) is an important extension for validating transfer to substantially larger foundation models.

References:

[7] Siméoni, Oriane, et al. "Dinov3." arXiv preprint arXiv:2508.10104 (2025).

[8] Bolya, Daniel, et al. "Perception encoder: The best visual embeddings are not at the output of the network." Advances in Neural Information Processing Systems 38 (2026): 60884-60937.

Authors · CommentOpenReview ↗

Updates on RegMix for Abdomen MRI Segmentation

Pretraining Mixture AMOS-CT AMOS-MRI BraTS-T1 BraTS-T2 HECKTOR BHSD
RegMix 82.3 68.9 53.0 63.1 69.3 59.3
Transfer-Aware 83.1 69.4 55.1 65.4 71.1 61.2
Authors · CommentOpenReview ↗

Follow-Up on the Rebuttal

Thank you again for the focused and constructive review. We wanted to follow up now that the additional experiments addressing your main concerns are complete and check if the concerns and the corresponding questions have been well addressed or not.

First, we expanded downstream evaluation across Uniform, Data-Proportional, Transfer-Naïve, Data Mixing Laws, RegMix, and Transfer-Aware. Transfer-Aware achieves the highest Dice on all six segmentation tasks and the highest mean classification accuracy, supporting MAE as a useful mixture-selection proxy rather than merely a low-level reconstruction metric.

Second, we added direct comparisons with RegMix and Data Mixing Laws. Transfer-Aware is better than RegMix at 10K and 100K, RegMix is slightly better at 50K, and they are effectively tied at 200K; we therefore explicitly avoid a claim of uniform dominance. Finally, we now report the full budget-dependent trend and narrow our claim: the method is most useful in the data-limited regime common to heterogeneous medical pretraining, rather than being claimed to provide constant gains at every scale.

We hope these new results and the revised framing address your concerns. We would appreciate any remaining feedback and respectfully hope you might reconsider your assessment if the concerns have been resolved.

Reviewer foD1OpenReview ↗
Rating
5/6
Confidence
4/5
Quality
3/4
Clarity
4/4
Significance
3/4
Originality
4/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper frames data allocation as a scaling-law optimization problem for 3D medical imaging, addressing two main challenges: heterogeneous scaling across domains and asymmetric (directional) transfer. The approach reveals hub-and-island structures: some domains strongly benefit others, while isolated domains need direct data investment. Their transfer-aware data allocation outperforms uniform and data-proportional sampling in image reconstructions, and also improves downstream tasks like disease classification and organ/lesion segmentation.

Strengths and weaknesses

Overall, the paper exhibits strong quality and clarity. It is well written and well organized, with intuitive explanations of the proposed method (e.g., lines 158–161 and 171–173) and a clearly motivated experimental design (lines 222–224), which make the technical contributions easy to follow. The selection of datasets for downstream validation is also carefully justified (lines 256–264), reinforcing the credibility of the empirical setup. Moreover, the authors discuss the limitations of their approach and include a broader impact section (in the Appendix though).

In terms of significance and originality, the work tackles an important and timely problem, data allocation, across heterogeneous medical imaging modalities, which is especially relevant with the rise of foundation models and agents. The proposed framework combines insights from scaling laws with transfer-aware sampling, offering a meaningful contribution that could encourage further research in data-centric model design.

However, there are some weaknesses that affect the overall strength of the evidence. Most notably, the evaluation lacks any assessment of anatomical plausibility. While the method achieves lower reconstruction error and improved downstream performance, it remains unclear whether these gains correspond to anatomically meaningful or clinically valid representations. This is particularly important in medical imaging, where lower reconstruction error can still produce anatomically inaccurate outputs. The absence of qualitative visualizations or quantitative structure-aware evaluations limits the ability to fully assess the quality of the learned representations. This concern is further amplified by the fact that no medical images are provided anywhere in the paper, including the appendix.

In the related work, the authors omits a key foundational reference in transfer learning for medical imaging [1], which limits credibility of their literature review. Finally, while the authors provide code as supplementary material and indicate that it will be released upon acceptance, this conditional availability slightly weakens reproducibility at the time of review.

Overall, the paper is clear, well-motivated, and addresses an important problem with an original perspective, but the lack of anatomical validation and qualitative evidence reduces confidence in the claimed improvements from a medical imaging standpoint.

[1] Raghu, M., Zhang, C., Kleinberg, J., & Bengio, S. (2019). Transfusion: Understanding transfer learning for medical imaging. Advances in Neural Information Processing Systems, 32.

Questions
  1. Anatomical and qualitative analysis. While the authors state that "This is important for 3D medical imaging because the domains differ not only in dataset size, but also in modality, anatomical coverage, spatial resolution, and signal characteristics." and claim that their method to "indicating strong anatomical regularity", these statements are not supported by quantitative metrics evaluating anatomical plausibility, nor by a thorough qualitative analysis of the resulting images.

  2. Position within related work. Could the authors discuss how their work differentiates with respect to key references such as [1]? And consider including it in their work.

  3. Code availability and reproducibility. Is it possible to make the code fully available during the review process, rather than conditionally upon acceptance, to support reproducibility and allow for a more thorough evaluation?

If the authors provide convincing answers to my questions, I will consider increasing my score.

Limitations

yes

Final justification

I appreciate that the authors strengthened the reproducibility aspect by providing an anonymized version of the code, and added additional analysis demonstrating the stability and robustness of their method. However, the authors did not address the related-work paper I mentioned.

While one could argue that that improved downstream segmentation and classification results suggest that the learned representation capture useful anatomical information, the rebuttal did not directly address my main concern regarding quantitative anatomical consistency measures for the proposed method.

That said, the rebuttal clarifies several of the concerns raised during the review process, and I agree with the AC's assessment that the overall reviewer feedback is largely positive. I have updated my score accordingly.

Formatting concerns

no

2 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We thank the reviewer for the encouraging and constructive assessment, particularly the high ratings for both clarity and originality (4/4). We appreciate the reviewer’s recognition of the paper’s novel perspective on directional cross-domain transfer and the clear presentation of the proposed framework. The reviewer’s questions identify valuable opportunities to strengthen the anatomical interpretation of our results, position the work more clearly relative to prior medical-transfer studies, and improve reproducibility. We address each point below and have revised the manuscript accordingly. We also appreciate the reviewer’s indication that satisfactorily addressing these questions could lead to a higher score.

Q1. Anatomical plausibility and qualitative analysis

We thank the reviewer for highlighting three related issues:
(1) whether the six domains are sufficiently heterogeneous to motivate domain-specific scaling parameters,
(2) whether the learned representations are anatomically meaningful, and
(3) whether our interpretation of the fitted exponent βi\beta_i was adequately supported.
Therefore, we address each point below:

1) Quantifying cross-domain heterogeneity

To further clarify on this statement "This is important for 3D medical imaging because the domains differ not only in dataset size, but also in modality, anatomical coverage, spatial resolution, and signal characteristics.", we explicitly quantify the differences among the six domains in the revised manuscript. The study spans CT, MRI, and PET across abdominal, brain, and head-and-neck anatomy, with substantial variation in native spatial resolution, matrix size, and signal units.

Domain Modality Anatomy Native spacing (mm) Native matrix Native intensity / signal range
ABD-CT CT Abdomen 0.67×0.67×2.00.67\times0.67\times2.0 512×512×201512\times512\times201 [−1018,439][-1018,439] HU
ABD-MRI MRI Abdomen 1.95×1.95×7.851.95\times1.95\times7.85 192×192×24192\times192\times24 [0,1.6×105][0,1.6\times10^5] a.u.
BRAIN-T1 MRI Brain 1.0×1.0×1.01.0\times1.0\times1.0 240×240×155240\times240\times155 [0,1943][0,1943] a.u.
BRAIN-T2 MRI Brain 1.0×1.0×1.01.0\times1.0\times1.0 240×240×155240\times240\times155 [0,1299][0,1299] a.u.
HN-CT CT Head-and-neck 0.98×0.98×1.50.98\times0.98\times1.5 512×512×238512\times512\times238 [−1000,244][-1000,244] HU
HN-PET PET Head-and-neck 4.0×4.0×4.04.0\times4.0\times4.0 144×144×87144\times144\times87 [0,2.3][0,2.3] SUV

The domains therefore differ not only in dataset size, but also in anatomical region, acquisition resolution, and signal statistics. Native slice thickness ranges from 1.01.0 mm to 7.857.85 mm, in-plane resolution ranges from 0.670.67 mm to 4.04.0 mm, and the signal units are fundamentally non-commensurable across HU, arbitrary MRI intensity, and SUV. This heterogeneity motivates learning domain-specific scaling parameters (Ei,Ci,βi)(E_i,C_i,\beta_i) and directed transfer coefficients τij\tau_{ij} rather than assuming homogeneous scaling and transfer behavior across all domains.

2) Anatomical usefulness of the learned representations

We agree that reconstruction loss alone is insufficient to establish anatomical or clinical validity. In our framework, MAE reconstruction serves as a controlled proxy objective for estimating the data mixture, while anatomical usefulness is evaluated through downstream structure-aware tasks. This follows prior 3D medical self-supervised learning studies showing that reconstruction- or MAE-based pretraining can learn representations transferable to clinical segmentation and classification tasks [4,5,6].

Specifically, Table 3 reports Dice scores on six organ and lesion segmentation benchmarks: AMOS-CT and AMOS-MRI for abdominal organs, BraTS-T1 and BraTS-T2 for brain tumors, HECKTOR for head-and-neck tumors, and BHSD for brain hemorrhage. Transfer-Aware pretraining improves Dice over Data-Proportional pretraining on all six benchmarks, with p<0.01p<0.01 under a paired Wilcoxon signed-rank test. Because these tasks require spatially accurate delineation of anatomical structures and pathological regions, the results provide quantitative evidence that anatomically relevant information learned during reconstruction pretraining transfers to downstream finetuning, rather than merely reducing voxel-level reconstruction error. We will clarify this interpretation while avoiding the stronger claim that segmentation performance alone establishes full clinical validity.

We also agree that qualitative evidence should be included. In the revised manuscript, we will add representative CT, MRI, and PET panels showing the input image, predicted organ or lesion mask, and ground-truth annotation. These visualizations will complement the quantitative Dice results and directly address the reviewer’s concern regarding the absence of medical-image examples.

3) Clarifying the interpretation of βi\beta_i

We also agree that the phrase ``indicating strong anatomical regularity'' was not sufficiently supported. The fitted exponent βi\beta_i measures only the empirical rate at which the reducible reconstruction loss changes with additional pretraining data; it does not independently measure anatomical regularity, domain difficulty, or representation quality.

We have therefore removed this anatomical attribution. In the revised manuscript, we will state the result directly: within the fitted budget range, a smaller βi\beta_i corresponds to a slower decay of the reducible loss as the pretraining budget increases, whereas a larger βi\beta_i corresponds to a faster decay. The optimized allocation is not determined by βi\beta_i alone, but jointly by the complete target-domain scaling law (Ei,Ci,βi)(E_i,C_i,\beta_i) and the directed transfer coefficients τij\tau_{ij}.

Q2. Position relative to Transfusion

We thank the reviewer for suggesting Raghu et al. (2019), which we will add to the related-work discussion as below:

"Transfusion studies transfer from 2D natural-image pretraining to 2D medical classification, asking when and where ImageNet representations benefit medical tasks relative to training from scratch. Our work addresses a complementary problem: given multiple heterogeneous 3D medical domains, how should a fixed pretraining budget be allocated across them?"

The two works differ in three main respects:

  • Transfer setting: natural-image-to-medical transfer in 2D versus directed transfer among heterogeneous 3D CT, MRI, and PET domains.
  • Goal: characterizing the benefit and feature reuse of pretraining versus predicting the transfer efficiency of each source-target pair and using it to optimize the data mixture.
  • Method: supervised transfer analysis versus self-supervised MAE pretraining combined with domain-specific scaling laws and a directed transfer matrix.

Thus, Transfusion provides an empirical characterization of when and where transfer occurs, whereas our framework converts cross-domain transfer into a quantitative, budget-dependent model for compute-aware data allocation. We view the two works as complementary and have clarified this distinction in the revision.

Q3. Code availability during review

We thank the reviewer for emphasizing the importance of code availability during review. We have now released an anonymized repository:

https://anonymous.4open.science/r/transfer-aware-scaling-3d-med-4564

The repository provides all implementations and supporting files for the central analysis in this work, starting from scaling-law calibration, transfer-aware mixture estimation, data mixture optimization, to UNETR pretraining and finetuning (i.e. segmentation model) scripts. It also includes environment and usage instructions to facilitate inspection and reproduction during the review period.

Reference:

[4] Xiao, Junfei, et al. "Delving into masked autoencoders for multi-label thorax disease classification." Proceedings of the IEEE/CVF winter conference on applications of computer vision. 2023. \

[5] Liu, Hong, et al. "M3AE: multimodal representation learning for brain tumor segmentation with missing modalities." Proceedings of the AAAI conference on artificial intelligence. Vol. 37. No. 2. 2023. \

[6] Masquelin, Axel HP, and Raúl San José Estépar. "Pretraining on Chronic Lung Inflammatory Disease Datasets to Enhance Indeterminant Lung Cancer Classification Using Masked Autoencoders." International Conference on Medical Image Computing and Computer-Assisted Intervention. Cham: Springer Nature Switzerland, 2025.

Authors · CommentOpenReview ↗

Follow-Up on the Rebuttal

Thank you again for the encouraging assessment and constructive questions. We wanted to briefly follow up if the concerns and the corresponding questions have been well addressed or not.

We clarified that MAE reconstruction is a representation-learning proxy rather than a measure of anatomical fidelity, and that anatomical usefulness is evaluated through structure-aware organ and lesion segmentation. The Transfer-Aware mixture achieves the highest Dice on all six segmentation benchmarks, and we commit to adding qualitative CT/MRI/PET segmentation overlays in the revision. We also quantified the domains' modality, anatomy, resolution, and signal differences, providing better clarification by removing the unsupported “anatomical regularity” attribution, added an explicit comparison with Transfusion, and provided the anonymized repository link here: https://anonymous.4open.science/r/transfer-aware-scaling-3d-med-4564.

We hope these changes fully address your three questions. Please let us know if any concern remains. If all the concerns are well addressed, we respectfully hope you will reconsider increasing the score.

Reviewer R15SOpenReview ↗
Rating
4/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This work addresses the central challenge of how to choose the data mixture for pretraining a unified 3D medical imaging model across CT, MRI, and PET domains. The paper argues that different domains scale differently and that transfer between domains is asymmetric. Based on this, the authors propose a transfer-aware scaling law that estimates domain-specific scaling exponents and a directed transfer matrix, then uses them to choose the pretraining data allocation. The main idea is interesting: instead of using uniform or data-proportional sampling, estimate which domains act as “hubs” and which act as “islands,” then allocate data accordingly. The experiments show better MAE reconstruction loss and improved downstream classification/segmentation compared with data-proportional pretraining.

Strengths and weaknesses

Strengths

The problem is important. Data mixture design is a real issue for medical foundation models, especially when different modalities and anatomies are mixed. The method is simple and interpretable. The transfer matrix gives a clear picture of which domain helps others. The “hub-and-island” idea is easy to understand and useful. The paper gives a good empirical story. Transfer-aware allocation improves MAE loss across budgets. The downstream results also show consistent improvement over data-proportional pretraining on classification and segmentation tasks. The experimental details are mostly clear.

Weaknesses

  1. this paper claimed the method as "guidance for 3d medical foundation model" but the exps were still small: 6 domains (500 or 150 volumes per domain). It's not enough to show the scale and generalize for clinical pretaining settings.
  2. the optimization objective is questionable: it minimizes the unweighted mean of raw MAE loss across modalities with very different intensity statistics (PET, CT, MRI). These losses are not commensurable, so the objective can be dominated by whichever domain has the larger dynamic range rather than representation quality, and this concern propagates to all downstream tasks.
  3. the datamix baselines are limited. Some adaptive or learned mixture methods such as temperature sampling, regmix regression or reweighting should be consider.
  4. In table 3, the paper should report downstream results for uniform and transfer-naive mixtures. why this work has 4 data mixture strategies but just report 2 in table 3?
  5. The headline "up to 58%" holds only at B=50K; gains shrink to ~5% and ~4% at 10K and 200K, so a result true at one of four budget points anchors the abstract.
  6. The key ablation is unconvincing: Transfer-Naive (0.0799 at 50K) is worse than Uniform and Data Pro. despite identical per-domain calibration, indicating a pathological allocation that inflates the apparent value of the transfer term, with no explanation.
Questions
  1. Does lower MAE loss consistently predict better downstream performance across all tested mixtures, not only Transfer-Aware vs Data-Proportional? how do the author justify minimizing the unweighted mean of raw MAE loss across modalities with different intensity distributions?
  2. Why are downstream results not reported for Uniform and Transfer-Naive mixtures?
  3. How stable is the learned transfer matrix across random seeds and model sizes?
  4. What happens if the number of domains grows from 6 to 20 or 50? Is the K*2 estimation still practical?
  5. Can the authors clarify the parameter-count inconsistency between the 121M model (ViT encoder) and the 12M proxy model (appendix)?
  6. Baselines: a comparison against at least one learned-mixture method (RegMix/DoReMi/BiMix)
Limitations

Partially. The most limitations are unacknowledged and, in my view, decisive: the commensurability of reconstruction loss across modalities, the dependence of the allocation on the arbitrary simplex floor, the circular nature of the main transfer-matrix validation, and the limited scale (single model size, 4 budgets, few seeds, 6 domains) relative to the "scaling laws".

Final justification

The rebuttal addresses almost all of my questions and concerns. After careful consideration, I decided to update my score accordingly.

Formatting concerns

No concerns

5 comments
Authors · CommentOpenReview ↗

Rebuttal Block 1 for Reviewer R15S

We thank the reviewer for the detailed, constructive, and technically engaged assessment. The review identifies several important issues concerning experimental scale, cross-modality loss aggregation, learned-mixture baselines, downstream validation, and the interpretation of our ablations. These comments motivated new analyses and experiments. Because the concerns are technically distinct, we address them in a sequence of comments following the reviewer’s original ordering.

W1. Experimental scale and relevance to clinical foundation-model pretraining

We agree that experiments on six domains with 150--500 selected volumes per domain are not sufficient to establish generalization to all clinical foundation-model pretraining settings. We will therefore revise the wording from broad “guidance for 3D medical foundation models” to a transfer-aware mixture-optimization framework validated in a controlled, heterogeneous 3D medical setting.

The current experiments are intended as a tractable proof of concept across CT, MRI, PET, multiple anatomies, and imbalanced domain sizes. Within this setting, the proxy-derived scaling law predicts the held-out 200K budget with 1.2% error and r=0.989r=0.989 across domains, and the resulting mixture improves the larger 121M encoder on classification and all six segmentation tasks. These results support generalization beyond the fitted proxy configurations, but not to arbitrarily larger clinical datasets, domain collections, or model capacities. We will also explicitly state this limitation and identify validation on larger clinical data populations, more domains, and multiple model sizes as necessary future work.

W2 / Q2. Commensurability of the cross-modality MAE objective

We agree that directly averaging reconstruction losses computed on raw CT, MRI, and PET intensity scales would be inappropriate, because the modality with the largest numerical range could dominate the objective. However, the losses used in our optimization are not computed on raw HU, MRI intensities, or PET SUVs. Each domain first undergoes modality- and anatomy-specific preprocessing and is mapped to the common range [−1,1][-1,1] before MAE is measured. Therefore, the original intensity dynamic range cannot directly determine a domain’s contribution to the objective.

We nevertheless agree that placing all modalities on the same numerical range does not guarantee that one unit of MAE has identical semantic meaning across domains. We therefore conducted an additional sensitivity analysis using dimensionless, target-specific relative losses. For a candidate mixture h\mathbf h, let Li(h,T)L_i(\mathbf h,T) denote its predicted MAE on target domain ii at budget TT. We evaluate two alternative normalizations:

  1. Relative MAE versus the single-domain reference. For each target, we divide its predicted loss by the lowest target-domain loss obtained from the pure single-domain pretraining configurations at the same budget.

  2. Relative MAE versus Uniform pretraining. For each target, we divide its predicted loss by that target’s loss under the Uniform mixture at the same budget.

Objective at T=100T=100K ABD-CT ABD-MRI BRAIN-T1 BRAIN-T2 HN-CT HN-PET Cosine vs. original
Unnormalized mean MAE 26.7 5.0 5.0 5.0 5.0 53.3 1.000
Relative MAE vs. single-domain reference 6.0 5.0 5.0 5.0 5.0 74.0 0.928
Relative MAE vs. Uniform reference 14.2 5.0 5.0 5.0 5.0 65.8 0.969

Although the exact allocation between ABD-CT and HN-PET changes, the main structure is preserved under both alternatives. The normalized solutions have cosine similarity 0.930.93--0.970.97 to the original allocation. Thus, the hub-and-island conclusion is not caused by one modality having a larger absolute MAE scale.

We also clarify that this concern does not directly propagate to the downstream metrics, which are independently measured using supervised accuracy, AUC, and Dice. It could propagate indirectly if the MAE objective selected a poor pretraining mixture. We test this possibility through the expanded downstream comparison across all mixture strategies: the mixture selected by our objective achieves the highest Dice on all six segmentation tasks and the highest mean classification accuracy. We therefore treat MAE as a mixture-selection proxy whose validity must be established through downstream transfer, rather than as a direct clinical-quality metric.

Finally, the unweighted mean represents an equal-target default, not a claim that all modalities have equal clinical importance. The framework directly supports an application-specific weighted objective, when particular modalities, anatomies, or clinical tasks should receive greater priority. We will clarify this assumption and add the normalization-sensitivity analysis to the revised manuscript.

Authors · CommentOpenReview ↗

Rebuttal Block 2 for Reviewer R15S

W3 / Q7. Comparison with learned and adaptive mixture methods

We agree that the original heuristic baselines were insufficient. We therefore added RegMix and Data Mixing Laws as stronger learned/scaling-law-based comparisons.

For RegMix, we sample anchored and Dirichlet mixtures under the same 5%5\% allocation floor, train each with the same 3D MAE proxy, evaluate all six target domains, fit one LightGBM regressor per target, and optimize the mean predicted loss.

Mixture 10K 50K 100K 200K
Data Mixing Laws 0.0855 0.0739 0.0395 0.0269
RegMix 0.09346 0.04367 0.03278 0.0224
Transfer-Aware 0.08010 0.04510 0.02640 0.02240

Transfer-Aware is 14.3% lower than RegMix at 10K and 19.5% lower at 100K; RegMix is 3.3% lower at 50K, and the methods are effectively tied at 200K. We therefore do not claim uniform dominance.

We also add Data Mixing Laws to the downstream comparison. RegMix learns a flexible mixture-to-loss regression, while Data Mixing Laws models the joint effect of mixture proportions and data scale. Our method instead explicitly separates domain scaling and directed source-to-target transfer through βi\beta_i and τij\tau_{ij}, yielding budget-dependent and interpretable hub-and-island allocations. We view these methods as complementary.

W4 / Q1 / Q3. Downstream results for all mixture strategies

We agree that we should report both the Transfer-Naive and uniform mixture for the downstream performances. We now include Uniform, Transfer-Naïve, Data Mixing Laws, and RegMix.

Classification: Accuracy (AUC), %.

Mixture OASIS-1 SynBrain-PET OrganMNIST3D
Uniform 66.9 (73.6) 69.7 (94.5) 88.9 (99.4)
Data-Proportional 67.5 (76.0) 71.9 (93.9) 89.7 (99.4)
Transfer-Naïve 66.3 (76.3) 73.6 (95.3) 90.1 (99.5)
Data Mixing Laws 67.5 (79.3) 73.2 (94.2) 89.8 (99.4)
RegMix 68.8 (79.7) 74.6 (95.3) 91.5 (99.5)
Transfer-Aware 69.7 (78.4) 78.1 (95.9) 90.3 (99.4)
Mixture AMOS-CT AMOS-MRI BraTS-T1 BraTS-T2 HECKTOR BHSD
Uniform 81.6 68.8 50.4 61.4 67.8 57.2
Data-Proportional 82.0 68.8 52.7 63.0 68.7 59.0
Transfer-Naïve 81.3 66.9 50.5 61.1 68.0 57.5
Data Mixing Laws 80.9 67.9 50.1 61.0 68.5 58.5
RegMix 82.3 68.9 53.0 63.1 69.3 59.3
Transfer-Aware 83.1 69.4 55.1 65.4 71.1 61.2

Transfer-Aware achieves the highest Dice on all six segmentation tasks with the lowest MAE reconstruction loss, improving over RegMix by 0.5 - 2.3 points, with an average gain of 1.57 Dice. It also obtains the highest mean classification accuracy (79.4% versus 78.3% for RegMix), although RegMix performs best on OrganMNIST3D and slightly better on mean AUC.

Across the five strategies with corresponding 100K reconstruction MAE, the Spearman correlation is ρ=−0.82\rho=-0.82 with mean Dice and ρ=−0.60\rho=-0.60 with mean classification accuracy. Thus, lower MAE is strongly associated with dense prediction performance, but is not perfectly predictive of every classification metric. We therefore treat MAE as a mixture-selection proxy, not as a universal clinical representation metric.

W5. Budget dependence of the “up to 58%” result

We agree that emphasizing only the maximum improvement at 50K overstated the consistency of the gain across budgets. Using the paper’s relative-gap definition,

Lbaseline−LTALTA\frac{L_{\mathrm{baseline}}-L_{\mathrm{TA}}}{L_{\mathrm{TA}}},

So the complete results are:

Baseline 10K 50K 100K 200K Mean
Data-Proportional 5% 58% 38% 4% 26%
Uniform 6% 49% 31% 2% 22%
Transfer-Naïve 4% 77% 51% 26% 40%

We will therefore revise the abstract and main text to report the complete budget-dependent trend rather than anchoring the claim on “up to 58%.” A more precise statement is:

Transfer-Aware reduces reconstruction error most strongly in the intermediate data regime; Data-Proportional incurs approximately 26% higher MAE on average across budgets, with gaps ranging from 4% to 58%.

The budget dependence is itself informative. At 10K, all methods operate in a strongly data-limited regime and remain relatively close. At 100K, the largest calibration budget before the held-out 200K evaluation and the budget used for downstream experiments -> the gap remains substantial at 38%. At 200K, the strongest methods converge as the fixed-capacity proxy approaches a loss-floor or capacity-limited regime. We therefore do not claim that the relative advantage is constant with scale, and we now explicitly distinguish the strongest intermediate-budget result from the smaller gains observed at the lowest and highest evaluated budgets.

Authors · CommentOpenReview ↗

Rebuttal Block 3 for Reviewer R15S

W6. Why Transfer-Naïve underperforms Uniform and Data-Proportional

We agree that the poor Transfer-Naïve result required an explicit explanation. Transfer-Naïve uses the same fitted per-domain self-scaling parameters as Transfer-Aware, but deliberately removes all cross-domain transfer by setting τij=δij\tau_{ij}=\delta_{ij}. Its surrogate therefore assumes that target domain ii benefits only from its directly allocated budget hiTh_iT.

This is an intentionally misspecified ablation rather than an alternative practical mixture strategy. Once transfer is removed, the optimizer selects the mixture that is optimal under the false assumption that all domains are independent. It can therefore over-allocate to domains with favorable isolated scaling behavior while under-allocating to source domains whose data would benefit several targets simultaneously. Uniform and Data-Proportional are less aggressive and can outperform this optimized but misspecified allocation. Such ablation should therefore be interpreted as testing whether per-domain scaling calibration alone is sufficient. Its failure shows that optimizing separate scaling curves while ignoring cross-domain interactions can be harmful.

We also agree that comparison with this ablation alone could exaggerate the apparent contribution of the transfer term. We therefore added RegMix and Data Mixing Laws as stronger practical baselines. At 100K, Transfer-Aware achieves 0.0264 MAE versus 0.0328 for RegMix and also outperforms RegMix on all six segmentation tasks. Thus, the empirical evidence for the method does not rely only on the large gap against the deliberately misspecified Transfer-Naïve ablation.

Q4. Stability across random seeds and model sizes

For seed stability, each τij\tau_{ij} is fitted jointly across three calibration budgets and 2--3 random seeds per budget, corresponding to 6--9 independent training runs per directed pair. We additionally performed 1,000 run-level bootstrap refits, jointly refitting the scaling laws, transfer matrix, and optimal mixture. The median cosine similarity to the reported allocation is 0.96. HN-PET remains above the allocation floor in 95.6% of refits and is the largest-weight domain in 82.5%; ABD-CT remains above the floor in 83.7%. Therefore, the qualitative hub-and-island structure is more stable than the exact numerical weights.

For model-size stability, the current evidence establishes transfer of the derived allocation, not invariance of every τij\tau_{ij}. The allocation fitted using the small proxy improves the larger 121M encoder downstream, but we have not refitted the complete transfer matrix at multiple capacities. Since model size may change EiE_i, βi\beta_i, and τij\tau_{ij}, we now state direct cross-scale estimation and a joint L(N,h,T)L(N,\mathbf h,T) formulation as future work.

Q5. Practicality of K2K^2 estimation for 20--50 domains

The exhaustive procedure requires KK self-domain and K(K−1)K(K-1) directed source - target configurations, or K2K^2 configurations in total: 36 for six domains, 400 for 20 domains, and 2,500 for 50 domains. Each configuration must also be evaluated over multiple budgets and seeds.

The proxy runs are small and parallelizable, so moderate expansion may remain feasible. However, we agree that exhaustive estimation for 50 domains would be expensive, and we do not claim that the current implementation scales unchanged to that setting.

The observed structured transfer matrix motivates sparse or low-rank estimation, hierarchical grouping by modality/anatomy, and uncertainty-guided selection of informative source--target pairs. These could substantially reduce the required experiments, but are not evaluated in the current work. We now identify the quadratic estimation cost explicitly as a limitation.

Q6. Clarification of the 12M and 121M parameter counts

We thank the reviewer for identifying an unclear architecture description. The two parameter counts correspond to different roles:

  • the 12M proxy model is used for the self-domain and directed-transfer experiments required to estimate the mixture surrogate;
  • the 121M target encoder is pretrained with the selected mixture and used for downstream classification and segmentation.

This proxy-to-target design is deliberate: running every domain pair, budget, and seed with the 121M model would remove much of the computational advantage of proxy-based mixture selection. However, the appendix did not separate the two configurations clearly enough. We will revise it to report their architectures, parameter counts, and experimental roles independently, and correct the compute discussion accordingly.

The downstream results support the specific claim that the proxy-derived allocation remains useful for the larger encoder. They do not prove that the fitted scaling and transfer parameters are invariant across model sizes, which we will clarify as our future investigation.

Reviewer P8KdOpenReview ↗
Rating
5/6
Confidence
4/5
Quality
3/4
Clarity
2/4
Significance
4/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The authors propose a strategy for designing a 3D medical data mixture for training foundation models. They formulate the problem as a scaling-law optimization problem. Masked autoencoding is used as a controlled proxy objective. They propose a transfer-aware scaling law with two components: domain-specific scaling-law exponents to capture the benefit of each domain from training budget and an asymmetric transfer matrix to measure the effectiveness of training in the source domain for the task in the target domain.

Strengths and weaknesses

Strengths

  1. The authors address an important problem, designed using the observation of different scaling behavior, the characteristic of directional cross-domain transfer.

  2. Experimental results are promising.

Weaknesses

  1. The domain-specific self-scaling segment has several ambiguities. First, it is unclear why the validation MAE should follow Eq. (6). Second, the scale of the training budget has not been explained. How can we ensure that the rightmost term in Eq. (6) remains on the same scale as EiE_i? How to find the value of βi\beta_i?

  2. Similar ambiguities are present in the context of Eq. (7). The authors have not explained why this equation should be used for predicting the loss. Hence, this equation appears to be an ad hoc formulation.

  3. I could not find any description of Table 3 in the main text. What do the values inside the parentheses indicate in this table?

  4. The authors have not evaluated the reproducibility of the results.

  5. A reference is missing in line 551.

Questions
  1. The authors should describe their method with a clear motivation for each design component.

  2. A reproducibility analysis of the results should be performed.

  3. The missing description of Table 3 and the missing reference should be added.

Limitations

Yes.

Final justification

The authors have addressed my major concerns.

Formatting concerns

A reference is missing.

1 comment
Authors · RebuttalOpenReview ↗
Rebuttal

We thank the reviewer for the thoughtful assessment and for recognizing both the significance of the problem (Significance: 4) and the value of explicitly modeling directional cross-domain transfer. We also appreciate the reviewer’s detailed feedback on the clarity of the scaling-law formulation, reproducibility, and presentation. These comments helped us identify several places where the motivation, units, fitting procedure, and empirical validation should be stated more explicitly. We address each concern below and will revise the manuscript accordingly.

Overview: Motivation of each design component

We agree with the reviewer that the motivation connecting the individual components of the method should be made more explicit. Our formulation proceeds in four steps. First, Eq.(6) models the diminishing returns of additional pretraining data within each target domain using a domain-specific shifted power law. Second, Eq.(7) introduces a directed transfer coefficient τij\tau_{ij} that converts data from source domain jj into an effective training budget for target domain ii. Third, for a general mixture, we use a first-order additive approximation to combine the effective contributions from all source domains as ∑jτijhjT\sum_j \tau_{ij}h_jT. Finally, substituting this effective budget into the self-domain scaling law yields the mixture-level loss predictor used for allocation optimization. We set τii=1\tau_{ii}=1 to anchor the transfer scale and allow τij≠τji\tau_{ij}\neq\tau_{ji} to capture asymmetric transfer. All scaling and transfer parameters are estimated from proxy experiments rather than manually specified. We clarify the assumptions, units, and fitting procedures for these components below.

W1. Clarification of the domain-specific self-scaling

1) Why should validation MAE follow Eq. (6)?

We do not assume that validation MAE must follow Eq. (6) exactly. Rather, Eq. (6) is a parsimonious shifted power-law model, motivated by the predictable diminishing-return learning curves observed across neural scaling studies [1,2,3]. These studies establish power laws as a widely used empirical model for loss or generalization error as data and compute increase, but they do not guarantee the scaling capability for medical MAE. We therefore validate Eq. (6) directly in our setting. Across all six domains, validation MAE decreases smoothly with increasing volume draws and is well described by the fitted power law. More importantly, the complete scaling formulation fitted using 10K, 50K, and 100K predicts the held-out 200K average loss as 0.0227 versus 0.0224 observed, with per-domain correlation r=0.989. Thus, Eq. (6) is an empirically validated surrogate for our data rather than an assumed universal law.

2) Training Budget and scale and estimation of βi\beta_i

Thank you reviewer for pointing this confusion out. We clarify that TT denotes the total pretraining budget measured in 3D volume draws, with T∈{10K,50K,100K,200K}T \in \{10\mathrm{K}, 50\mathrm{K}, 100\mathrm{K}, 200\mathrm{K}\}. To make the scale explicit, Eq.~(6) can equivalently be written as $L_i(T) = E_i + C_i\left(\frac{T}{T_0}\right)^{-\beta_i},$
where T0=10KT_0=10\mathrm{K} is a fixed reference budget. Because T/T0T/T_0 is dimensionless, EiE_i and Ci(T/T0)−βiC_i(T/T_0)^{-\beta_i} are both expressed in validation-MAE units. They do not need to have the same numerical magnitude and need to have the same units. Changing T0T_0 only rescales CiC_i and does not affect βi\beta_i, the fitted curve, or its predictions. For each domain, EiE_i, CiC_i, and βi\beta_i are jointly fitted from the observed validation MAE across the training budgets. Thus, βi\beta_i is estimated from the rate at which validation loss decreases with additional pretraining data, rather than being manually specified.

W2: Motivation for Eq.(7).

We agree with the reviewer that the motivation for Eq.(7) was too brief. To clarify here, Eq.(7) is not an independent ad hoc formulation, which follows from Eq.(6) under an effective-data assumption. For a target domain ii, Eq.(6) describes the loss as a function of the amount of target-domain training signal. We model TT samples from source domain jj as providing τijT\tau_{ij}T target-ii-equivalent samples, where τij∈[0,1]\tau_{ij}\in[0,1] is the directed transfer efficiency. Substituting this effective budget into Eq.(6) gives
$L_{i\leftarrow j}(T) = E_i + C_i\left(\frac{\tau_{ij}T}{T_0}\right)^{-\beta_i}$
This formulation preserves the intrinsic scaling behavior of target domain ii, represented by (Ei,Ci,βi)(E_i,C_i,\beta_i), while using only τij\tau_{ij} to capture how efficiently source domain jj transfers to it. It also recovers the self-domain law exactly when j=ij=i and τii=1\tau_{ii}=1. Each τij\tau_{ij} is fitted from the observed validation MAE on target ii after pretraining exclusively on source jj across multiple budgets, rather than being manually specified. We will further revise the manuscript to make this effective-budget derivation and its empirical nature explicit.

W3. Table 3 and the missing reference

Thank you reviewer for identifying this issue. The downstream results are described in Section 6, including the OASIS-1 improvement from 66.9% to 69.7% accuracy and the improvements across all segmentation tasks, but the corresponding cross-reference to Table 3 was lost during typesetting. We will restore the Table 3 reference in Section 6 so that the discussion and table are clearly linked in the final version of the paper. For the classification columns in Table 3, the value outside parentheses is accuracy, while the value inside parentheses is AUC. The asterisk denotes p<0.01 under a paired Wilcoxon signed-rank test against the Data-Proportional pretraining baseline. Although this information appeared in the header, we have repeated it in the caption for clarity. The missing reference near line 551 corresponds to the AdamW [?] citation in Appendix A.4. We will also add the corresponding references in the final version of the paper.

W4. Reproducibility and stability analysis

We agree that the reproducibility of both the measured performance and the inferred transfer structure should be quantified. We therefore provide two complementary analyses.

1) Reproducibility across random seeds

We repeat each available mixture experiment across independent random seeds (i.e. 3 seeds) and report the mean and standard deviation of the validation MAE below. Across the evaluated budgets, the variation across seeds is generally smaller than the differences between mixture strategies, supporting that the observed improvements are not caused by a favorable initialization.

Pretraining strategy 10K 50K 100K 200K
Transfer-Aware 0.0812 ±\pm 0.0011 0.0496 ±\pm 0.0045 0.0264 ±\pm 0.0031 0.0224 ±\pm 0.0022
Uniform 0.0837 ±\pm 0.0016 0.0533 ±\pm 0.0138 0.0345 ±\pm 0.0013 0.0227 ±\pm 0.0075
Data-Proportional 0.0852 ±\pm 0.0009 0.0639 ±\pm 0.0073 0.0365 ±\pm 0.0075 0.0283 ±\pm 0.0043
Transfer-Naive 0.0845 ±\pm 0.0010 0.0696 ±\pm 0.0102 0.0399 ±\pm 0.0064 0.0283 ±\pm 0.0050

From 10K to 200K, Transfer-Aware achieves the lowest mean validation MAE and remains robust under seed variation. We will add the number of independent seeds for each budget and the complete per-seed results to the appendix.

2) Reproducibility of the inferred transfer structure

Random-seed variation in the final training runs does not by itself measure uncertainty in the fitted transfer matrix or optimized mixture. We therefore perform a run-level bootstrap with 1,000 resamples. For each resample, we refit the domain-specific scaling parameters (Ei,Ci,βi)(E_i,C_i,\beta_i) and transfer coefficients τij\tau_{ij}, and then re-optimize the mixture h∗h^*.

Domain Reported h∗h^* (%) Bootstrap mean (%) 95% bootstrap interval (%)
ABD-CT 26.7 25.4 [5.0, 75.0]
ABD-MRI 5.0 5.8 [5.0, 13.7]
BRAIN-T1 5.0 8.9 [5.0, 27.5]
BRAIN-T2 5.0 5.8 [5.0, 15.7]
HN-CT 5.0 6.3 [5.0, 17.3]
HN-PET 53.3 47.8 [5.0, 73.9]

Although the exact allocation weights have uncertainty at the current proxy scale, the qualitative hub-and-island structure is stable:

  • HN-PET is above the minimum allocation in 95.6% of bootstrap refits and receives the largest weight in 82.5%.
  • ABD-CT is above the minimum allocation in 83.7% of refits.
  • ABD-CT and HN-PET are the two largest allocations in 67.8% of refits.
  • The median cosine similarity between the bootstrapped and reported allocations is 0.96.
  • The median Spearman correlation between bootstrapped and reported transfer coefficients is 0.78.

These results support reproducibility of the inferred transfer structure, while the broad per-domain intervals transparently show that the precise allocation percentages are less certain than the overall hub-and-island pattern.

3) Anonymous code release and end-to-end reproducibility

To further support exact reproduction, we have released an anonymized code repository: https://anonymous.4open.science/r/transfer-aware-scaling-3d-med-4564
The repository provides the implementation and instructions for fitting the domain-specific scaling laws, estimating the directed transfer matrix τ\tau, optimizing the transfer-aware mixture h∗h^*, and conducting the bootstrap stability analysis reported above. For datasets that cannot be redistributed because of medical-data access restrictions, we provide the required data format and preprocessing instructions

[1] Hestness, Joel, et al. "Deep learning scaling is predictable, empirically." arXiv preprint arXiv:1712.00409 (2017).
[2] Rosenfeld, Jonathan S., et al. "A Constructive Prediction of the Generalization Error Across Scales." ICLR (2020).
[3] Kaplan, Jared, et al. "Scaling laws for neural language models." arXiv preprint arXiv:2001.08361 (2020).

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Missing a submission?

Loading the discussion…