When Does Flow Matching Help Deterministic Multimodal Prediction: A Spatial Transcriptomics Study
Haoran Xu, Wei Yuan, Xiao Han
NeurIPS 2026
TL;DR. Flow matching can improve gene-expression prediction from tissue images when noisy molecular information is used as shared tissue context rather than a shortcut for individual locations.
Abstract. Flow matching is increasingly used beyond open-ended generation, including prediction tasks whose outputs are effectively deterministic, yet it remains unclear why flow matching helps when diversity is not the objective. We study this question in histology-conditioned spatial transcriptomics (ST) prediction, a challenging, sparse, high-dimensional task where thousands of spatially correlated spot-level observations arise from a limited number of heterogeneous tissue slides, and direct regression with pathology foundation features is already competitive. Repeated sampling with different initial Gaussian noises under the same histology input produces nearly identical predictions, indicating that output diversity does not explain the benefit of flow matching in this setting. We instead identify intermediate flow states as time-indexed target-side signals: they retain target-related information while remaining mixed with source noise. Their benefit emerges when this information is selectively routed into histology representations while preserving slide-level condition alignment. Guided by this mechanism, we instantiate conditional flow matching with a simple gated self-attention architecture to model interactions between histology tokens and noisy ST states, improving spatial-correlation metrics over regression and flow-based baselines. We further probe this mechanism through component ablations, context analyses, inference-time routing interventions, and additional evaluations in spatial proteomics and with a Qwen-gated-attention backbone. Together, these experiments provide a mechanistic account of when intermediate flow states can serve as structured target-side supervision in deterministic histology-conditioned spatial molecular prediction.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:47 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
Summary
The paper analyzes why conditional flow matching can improve deterministic histology to spatial transcriptomics prediction. It proposes a flow model with gated self-attention over histology features and time-indexed noisy transcriptomic tokens. The authors argue that the target-side state available during training acts as privileged information. Across cancer datasets and an IDC cohort, the proposed model generally improves pearson correlation over the reported regression, STEM, and STFlow baselines.
Main strengths
- The paper asks a useful conceptual question rather than only reporting a new architecture
- The empirical study spans several datasets and includes targeted ablations.
- The presentation is mostly clear, and the repeated-sampling result is interesting
Main weaknesses / missing
- The central causal attribution is not isolated by an exactly matched deterministic endpoint-regression baseline using a controlled setup. As mentioned by the reviewers, the reported ablations change more than just flow supervision.
- The discussion explains target-side information in idealized assumptions, but it is unclear whether this generalizes or is specific to this construction
- The appendix has significance tests and for IDC seed-level standard errors, but uncertainty is not comprehensively reported per dataset, slide, or patient, and no spatial-coherence metric is included.
- The gains are consistent across datasets but modest on IDC and in comparison to the closest ablations, making an exactly matched baseline important for the claims.
- Evidence is limited to histology-conditioned ST prediction, so broader conclusions about deterministic multimodal prediction require another task.
Potential improvements
The paper would improve with a fairer architecture- and budget-controlled endpoint-regression baseline, uncertainties (e.g., per-dataset multi-seed or bootstrapped per-slide/patient), and a spatial-coherence metric. A response should also explain how and why the existing ablations isolate flow supervision and not extra target-conditioned computation. Without evidence on another deterministic multimodal task, the broader claims should be narrowed to histology-conditioned ST prediction.
Post Rebuttal
The authors' response adds a matched regression baseline, spatial proteomics settings, scaling, uncertainty estimation, and further results. While these considerably strengthen the paper and address the initial reviews, the authors should nonetheless appropriately narrow the claim from deterministic multimodal prediction in general to the special case of histology-conditioned spatial molecular prediction. The paper presents a relevant and, after the rebuttal, well-controlled finding about the type of tasks considered and warrants a publication. The hypothesized privileged information explanation therefore should be limited to this scope and, additionally, it should be made clear that it is a hypothesis with evidence instead of being empirically proven, which would require more breadth of experiments. Additionally, it should be highlighted that the current experiments do not establish that the true conditional distribution is deterministic so the final paper should avoid this claim and restrict the conclusion to the deterministic behavior observed in the benchmarks. Overall, because the narrower scope remains highly relevant and the findings novel, I recommend acceptance with the paper phrased as a focused mechanistic study in the context of histology-conditioned prediction.
Final justification
See above.
- Final justification
- See above.
Read meta-review
Meta-review
Summary
The paper analyzes why conditional flow matching can improve deterministic histology to spatial transcriptomics prediction. It proposes a flow model with gated self-attention over histology features and time-indexed noisy transcriptomic tokens. The authors argue that the target-side state available during training acts as privileged information. Across cancer datasets and an IDC cohort, the proposed model generally improves pearson correlation over the reported regression, STEM, and STFlow baselines.
Main strengths
- The paper asks a useful conceptual question rather than only reporting a new architecture
- The empirical study spans several datasets and includes targeted ablations.
- The presentation is mostly clear, and the repeated-sampling result is interesting
Main weaknesses / missing
- The central causal attribution is not isolated by an exactly matched deterministic endpoint-regression baseline using a controlled setup. As mentioned by the reviewers, the reported ablations change more than just flow supervision.
- The discussion explains target-side information in idealized assumptions, but it is unclear whether this generalizes or is specific to this construction
- The appendix has significance tests and for IDC seed-level standard errors, but uncertainty is not comprehensively reported per dataset, slide, or patient, and no spatial-coherence metric is included.
- The gains are consistent across datasets but modest on IDC and in comparison to the closest ablations, making an exactly matched baseline important for the claims.
- Evidence is limited to histology-conditioned ST prediction, so broader conclusions about deterministic multimodal prediction require another task.
Potential improvements
The paper would improve with a fairer architecture- and budget-controlled endpoint-regression baseline, uncertainties (e.g., per-dataset multi-seed or bootstrapped per-slide/patient), and a spatial-coherence metric. A response should also explain how and why the existing ablations isolate flow supervision and not extra target-conditioned computation. Without evidence on another deterministic multimodal task, the broader claims should be narrowed to histology-conditioned ST prediction.
Post Rebuttal
The authors' response adds a matched regression baseline, spatial proteomics settings, scaling, uncertainty estimation, and further results. While these considerably strengthen the paper and address the initial reviews, the authors should nonetheless appropriately narrow the claim from deterministic multimodal prediction in general to the special case of histology-conditioned spatial molecular prediction. The paper presents a relevant and, after the rebuttal, well-controlled finding about the type of tasks considered and warrants a publication. The hypothesized privileged information explanation therefore should be limited to this scope and, additionally, it should be made clear that it is a hypothesis with evidence instead of being empirically proven, which would require more breadth of experiments. Additionally, it should be highlighted that the current experiments do not establish that the true conditional distribution is deterministic so the final paper should avoid this claim and restrict the conclusion to the deterministic behavior observed in the benchmarks. Overall, because the narrower scope remains highly relevant and the findings novel, I recommend acceptance with the paper phrased as a focused mechanistic study in the context of histology-conditioned prediction.
1 comment
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper investigates why flow matching can be useful for deterministic multimodal prediction, using histology-conditioned spatial transcriptomics prediction as the main application. The authors argue that the benefit of flow matching does not mainly come from sampling diversity, generic noise injection, or simply using a more complex model. Instead, they propose that intermediate flow states provide paired and time-indexed target-side supervision, which becomes useful only when the model can selectively integrate this information with histology representations. To test this hypothesis, the paper introduces a relatively simple gated self-attention architecture that jointly processes histology tokens and noisy ST-state tokens. The authors compare against regression, STEM, and STFlow, and provide controlled ablations on the role of intermediate states, time conditioning, pairing, and gated interaction.
Strengths and weaknesses
Strengths:
- The paper studies an interesting and timely question. Flow matching and diffusion-style methods are increasingly used in conditional prediction tasks, but it is not always clear why they help when the desired output is effectively deterministic. This paper provides a focused investigation of this issue.
- The central interpretation is useful. Viewing intermediate flow states as structured target-side training signals, rather than as a source of output diversity, is a meaningful perspective for deterministic multimodal prediction.
- The ablation design is relatively strong. The comparisons with clean target tokens, permuted intermediate states, removal of time conditioning, vanilla self-attention, and removal of intermediate states help isolate the mechanism more carefully than a standard performance-only paper.
- The proposed model is intentionally simple. This makes the mechanistic analysis easier to interpret and reduces the concern that the improvement is purely due to a highly specialized or over-engineered ST architecture.
Weaknesses:
- The empirical scope is still limited. Although the paper frames the conclusion as a broader principle for deterministic multimodal prediction, all experiments are within histology-conditioned spatial transcriptomics. It would be stronger to include another deterministic multimodal prediction task, or at least another biological setting, to support the broader claim.
- The modeling novelty is moderate. Gated self-attention over concatenated multimodal tokens is not by itself a major architectural innovation. The main contribution is the mechanistic interpretation and diagnostic study, so the paper should position itself more explicitly as an analysis-driven contribution rather than a new architecture paper.
- Baseline fairness needs more clarification. The paper states that all methods use the same pathology foundation model features, but more details are needed on whether STEM, STFlow, regression, and the proposed model are matched in training budget, hyperparameter tuning, gene-panel construction, slide-level splits, and sampling/inference settings.
- Statistical robustness is underreported. The main tables appear to report point estimates. Given the sensitivity of spatial transcriptomics prediction to slide splits, gene selection, random seeds, and spot grouping, the paper should report standard deviations or confidence intervals over multiple runs.
- The theoretical analysis is useful but still idealized. The Bayes-risk and Gaussian arguments support the intuition that intermediate states contain target-side information, but they do not fully explain why the specific gated self-attention mechanism should reliably extract useful information in sparse, high-dimensional ST data.
Questions
-
Are the reported results averaged over multiple random seeds? If not, can the authors provide standard deviations or confidence intervals?
-
How sensitive is the method to the number of histology-ST pairs grouped into each token sequence? Does the performance gain persist when the context size is varied?
-
Can the authors include a regression baseline with the same multi-spot gated token architecture but without flow states? This would better separate the benefit of multi-spot token coupling from the benefit of flow-induced intermediate states.
-
How does the method perform under stricter slide-level or patient-level splits, especially when the histology distribution shifts across slides or cancer types?
Limitations
yes
Final justification
Thanks for your reply. I will update your rate to 4.
Formatting concerns
No
4 comments
Rebuttal
We thank Reviewer LQRt for recognizing that our paper addresses an interesting and timely question, provides a useful interpretation of intermediate flow states as structured target-side training signals, and supports this interpretation through relatively strong ablations and an intentionally simple, interpretable architecture. We also appreciate the reviewer’s careful assessment and concrete questions regarding baseline fairness, context-size sensitivity, theoretical assumptions, statistical robustness, and data splits. We added an exactly matched endpoint-regression baseline with the same multi-spot gated-token architecture but without flow states; its full six-dataset comparison and uncertainty analysis are reported in our response to Reviewer zRNh. Another bological setting--Spatial-proteomics--and evaluation with a more established, higher-capacity Qwen gated-attention backbone are reported in our response to Reviewer 2oSA. Here, we focus on the interaction between flow states and multi-token context, an inference-time interventional test of the proposed routing mechanism, and the evaluation protocol.
Context-Matched Endpoint Regression: We added Context-Matched Endpoint Regression (CM-Regression) to isolate the contribution of flow-induced states from that of multi-token processing. CM-Regression uses the same pathology-foundation-model features, context size , Transformer capacity, prediction head, grouping/reshuffling strategy, and data splits as Ours. However, it receives no ST-state tokens, samples no time , and directly predicts the clean endpoint using MSE. The comparison therefore controls for architecture, parameter budget, and multi-spot processing.
Context-size sensitivity and spatial context: Global grouping deliberately avoids a favorable spatial neighborhood: tokens are randomly reshuffled and may come from unrelated slides. For local grouping, we select a center spot within the current slide, retrieve its spatially nearest spots, and jointly predict the resulting local patch..
| Sampling | Method | M | PCC-200 ↑ | PCC-100 ↑ | PCC-50 ↑ | MSE ↓ | MAE ↓ |
|---|---|---|---|---|---|---|---|
| Global | Ours | 1 | 0.627 | 0.798 | 0.855 | 1.546 | 0.917 |
| Global | Ours | 64 | 0.658 | 0.819 | 0.885 | 1.209 | 0.802 |
| Global | Ours | 128 | 0.660 | 0.820 | 0.885 | 1.333 | 0.849 |
| Global | CM-Regression | 1 | 0.655 | 0.817 | 0.884 | 1.370 | 0.847 |
| Global | CM-Regression | 64 | 0.640 | 0.806 | 0.875 | 1.364 | 0.853 |
| Global | CM-Regression | 128 | 0.643 | 0.810 | 0.879 | 1.352 | 0.866 |
| Local | Ours | 128 | 0.686 | 0.836 | 0.898 | 1.819 | 0.989 |
| Local | CM-Regression | 128 | 0.626 | 0.802 | 0.868 | 1.697 | 1.009 |
At , where no cross-token coupling is available, CM-Regression outperforms Ours. Once multiple tokens are jointly processed, the result reverses. Increasing from 1 to 64 improves our PCC-200 from 0.627 to 0.658, and Ours subsequently outperforms CM-Regression by +0.018/+0.013/+0.010 on PCC-200/100/50. The advantage remains consistently positive at .
In contrast, CM-Regression obtains its strongest PCC values at and does not benefit from larger globally reshuffled groups. Because the two methods share the same multi-token gated architecture, this contrast cannot be explained by token coupling alone. It shows that the advantage lies in the gated integration of flow-induced target-side states, which allows the model to exploit inter-sample coupling that endpoint regression does not use in the same way.
Replacing global reshuffling with local sampling at further improves Ours from 0.660/0.820/0.885 to 0.686/0.836/0.898 on PCC-200/100/50, whereas CM-Regression decreases from 0.643/0.810/0.879 to 0.626/0.802/0.868. Under the same local context, Ours consequently exceeds CM-Regression by +0.060/+0.034/+0.030 across the three PCC panels.
This further shows that flow matching makes spatial context more usable: the evolving noisy-ST sequence supplies a time-indexed target-modality scaffold through which gated attention can organize and couple neighboring histology representations. CM-Regression observes the same local histology context but lacks this evolving target-side state and therefore does not obtain the same contextual benefit. This finding also motivates future extensions based on more structured or adaptive spatial-context construction.
Empirical test of the idealized theoretical mechanism: We agree that the Bayes-risk and Gaussian analyses are idealized. They establish that intermediate states can contain target-side information, but do not guarantee that a trained gated Transformer will learn to extract this information in sparse, high-dimensional ST data. We therefore added fixed-checkpoint inference-time routing interventions. Without retraining or modifying any model parameters, we mask selected attention routes at every integration step.
For consistent notation across both backbones, no_ig prevents image/spot queries from attending to the target-side branch, no_gi blocks the reverse direction, no_cross blocks both directions, and no_gg blocks interactions within the target-side branch. half_no_gating disables gating during the latter half of integration.
| Backbone | Intervention | PCC | MSE | MAE |
|---|---|---|---|---|
| Ours | none | 0.6864 | 1.8461 | 1.0270 |
| Ours | no_cross | 0.6448 | 1.6149 | 0.9210 |
| Ours | no_ig | 0.6448 | 1.6149 | 0.9210 |
| Ours | no_gi | 0.6846 | 1.3644 | 0.8980 |
| Ours | no_gg | 0.6834 | 1.8113 | 1.0004 |
| Ours | half_no_gating | 0.6858 | 1.8379 | 1.0209 |
| Qwen | none | 0.6808 | 1.5897 | 0.8775 |
| Qwen | no_cross | 0.6481 | 1.3823 | 0.8536 |
| Qwen | no_ig | 0.6481 | 1.3828 | 0.8537 |
| Qwen | no_gi | 0.6807 | 1.5785 | 0.8758 |
| Qwen | no_gg | 0.6803 | 1.5833 | 0.8738 |
| Qwen | half_no_gating | 0.6795 | 2.5761 | 1.2416 |
The routing intervention reveals a clear directional dependence. In Ours, preventing image/spot tokens from reading the target-side branch reduces PCC from 0.6864 to 0.6448, whereas blocking the reverse direction changes PCC only to 0.6846. Blocking both directions produces the same result as blocking image-to-target attention alone, identifying the route from the target-side branch into the image/spot representation as the relevant output pathway.
We observe the same pattern using a larger and more established Qwen gated-attention backbone. Blocking image/spot tokens from reading the noisy target-side state reduces PCC from 0.6808 to 0.6481, whereas blocking the reverse direction changes it only to 0.6807.
Taken together, the two-backbone interventions show that prediction functionally relies on gated routing from the evolving noisy target-side state into the image/spot tokens. Combined with our existing time-conditioning ablation, this provides convergent evidence that flow matching creates an effective learning signal by incorporating time-indexed target-side information into histology representations through gated attention. We interpret this as empirical support for the proposed mechanism rather than a claim that all idealized theoretical assumptions hold exactly.
Random seeds, uncertainty, baseline parity, and data splits: The results in the main Tables 1 and 2 are averages over the predefined test splits rather than results selected from a favorable split. For multi-seed evaluation, we use seeds 1, 40, and 2026. All stochastic neural methods are evaluated using the same seeds, and the full mean ± standard deviation results and paired slide-level uncertainty analysis are reported in our response to Reviewer zRNh.
For every within-dataset comparison, all methods use exactly the same pathology features, gene panels, preprocessing, and patient splits. Each split is trained and evaluated independently, with all samples from the same patient retained in the same partition whenever multiple patients are available. The dataset composition and predefined splits are summarized below.
| Experiment | Dataset | Patients | Samples | Spots/Cells | Splits |
|---|---|---|---|---|---|
| Main Table 2 | LYMPH | 4 | 4 | 19,960 | 4 |
| LUNG | 2 | 2 | 3,888 | 2 | |
| COAD | 3 | 4 | 20,316 | 3 | |
| PAAD | 3 | 3 | 8,340 | 3 | |
| PRAD | 2 | 23 | 56,442 | 2 | |
| CCRCC | 24 | 24 | 67,008 | 6 | |
| Ablation | IDC-80k | 4 | 10 | 80,591 | 2 |
| Scaling | IDC-180k | 7 | 17 | 173,207 | 2 |
| Proteomics | CRC-CODEX | 35 | 140 | 218,689 | 1 |
| Visium PEX Pathology | 1 | 2 | 9,925 | 1 | |
| Visium PEX Tonsil | 1 | 1 | 4,194 | 1 |
The main comparison is trained and evaluated separately on each split. To make the mechanistic ablations more reliable, we report them on the larger IDC cohorts. We can additionally provide corresponding results on the other datasets in the supplementary material.
Revision to the paper: We will add CM-Regression, the context-size and global-versus-local sampling analyses, and the inference-time routing interventions under both our original and Qwen backbones. We will also expand the supplement with method-specific implementation details and clarify the empirical scope of our theoretical analysis. All gated-attention variants use identical architectures, training configurations, and evaluation protocols without variant-specific hyperparameter tuning; the external STFlow and STEM baselines retain their recommended configurations while sharing the same input features, gene panels, data splits, and evaluation samples. These revisions connect the idealized analysis to its empirical routing evidence and sharpen our central claim around the interaction among flow-induced target-side states, gated routing, and multi-token context.
Additional multi-seed uncertainty analysis: We thank the reviewer for emphasizing this point. To answer the question directly, the results for Ours in the original Tables 1 and 2 are averaged over seeds 1, 40, and 2026. The character limit prevented us from including the complete uncertainty table in our main response. To make these results directly accessible, we will post a separate follow-up table in this discussion thread, reporting mean ± standard deviation and paired 95% confidence intervals for the principal comparisons.
Follow-up: multi-seed uncertainty (mean ± standard deviation). This is the follow-up analysis promised in our previous comment. We first report mean ± standard deviation across seeds 1, 40, and 2026 for Ours, CM-Regression, and STFlow. Paired confidence intervals will be reported separately using a unified aggregation and resampling protocol.
| Dataset | Method | PCC-200 ↑ | MSE ↓ | MAE ↓ | Spearman ↑ | LISA ↑ |
|---|---|---|---|---|---|---|
| COAD | STFlow | 0.4010 ± 0.0241 | 1.8582 ± 0.0295 | 0.9816 ± 0.0099 | 0.3975 ± 0.0237 | 0.2266 ± 0.0179 |
| CM-Regression | 0.4357 ± 0.0029 | 1.8213 ± 0.0326 | 0.9843 ± 0.0104 | 0.4270 ± 0.0034 | 0.2348 ± 0.0027 | |
| Ours | 0.4591 ± 0.0198 | 1.8812 ± 0.0169 | 0.9958 ± 0.0103 | 0.4476 ± 0.0032 | 0.2475 ± 0.0038 | |
| LYMPH | STFlow | 0.2615 ± 0.0387 | 0.7133 ± 0.0592 | 0.5779 ± 0.0209 | 0.2772 ± 0.0164 | 0.1237 ± 0.0371 |
| CM-Regression | 0.3083 ± 0.0002 | 0.6711 ± 0.0306 | 0.6073 ± 0.0131 | 0.2965 ± 0.0015 | 0.1573 ± 0.0049 | |
| Ours | 0.3233 ± 0.0049 | 0.5708 ± 0.0207 | 0.5658 ± 0.0086 | 0.3092 ± 0.0058 | 0.2008 ± 0.0036 | |
| LUNG | STFlow | 0.6273 ± 0.0047 | 1.1123 ± 0.0146 | 0.7955 ± 0.0067 | 0.5815 ± 0.0029 | 0.4079 ± 0.0063 |
| CM-Regression | 0.6225 ± 0.0014 | 1.1005 ± 0.0228 | 0.7967 ± 0.0102 | 0.5733 ± 0.0006 | 0.3977 ± 0.0027 | |
| Ours | 0.6350 ± 0.0026 | 1.0741 ± 0.0313 | 0.7898 ± 0.0114 | 0.5929 ± 0.0033 | 0.4187 ± 0.0029 | |
| PAAD | STFlow | 0.4852 ± 0.0141 | 0.9461 ± 0.0656 | 0.7389 ± 0.0251 | 0.4525 ± 0.0136 | 0.2493 ± 0.0179 |
| CM-Regression | 0.4962 ± 0.0006 | 0.8509 ± 0.0394 | 0.7069 ± 0.0157 | 0.4587 ± 0.0001 | 0.2492 ± 0.0019 | |
| Ours | 0.4921 ± 0.0035 | 0.8554 ± 0.0226 | 0.6980 ± 0.0091 | 0.4635 ± 0.0024 | 0.2490 ± 0.0046 | |
| PRAD | STFlow | 0.2983 ± 0.0641 | 0.6735 ± 0.0343 | 0.5779 ± 0.0153 | 0.2694 ± 0.0715 | 0.0933 ± 0.0387 |
| CM-Regression† | 0.3576 ± 0.0100 | 0.5986 ± 0.0116 | 0.5755 ± 0.0080 | 0.3440 ± 0.0076 | 0.1333 (SD < 0.0001) | |
| Ours | 0.3777 ± 0.0023 | 0.6297 ± 0.0143 | 0.5712 ± 0.0026 | 0.3597 ± 0.0022 | 0.1417 ± 0.0072 | |
| CCRCC | STFlow | 0.2588 ± 0.0456 | 0.6266 ± 0.0292 | 0.5880 ± 0.0078 | 0.2743 ± 0.0294 | 0.0803 ± 0.0128 |
| CM-Regression | 0.2827 ± 0.0079 | 0.6038 ± 0.0072 | 0.6040 ± 0.0031 | 0.2780 ± 0.0069 | 0.0833 ± 0.0011 | |
| Ours | 0.3140 ± 0.0030 | 0.5888 ± 0.0043 | 0.5895 ± 0.0049 | 0.3033 ± 0.0014 | 0.0865 ± 0.0041 |
Across the six datasets, Ours achieves the highest PCC-200 on five datasets and the highest Spearman correlation on all six, with limited variability across seeds.
Follow-up: paired slide-level confidence intervals. In addition to the multi-seed mean ± standard deviation reported above, we quantify test-sample uncertainty for the two principal comparisons, Ours versus CM-Regression and Ours versus STFlow. The analysis pools the 60 paired test slides/samples across the six datasets. Confidence intervals use 20,000 paired bootstrap resamples, and two-sided p-values use 20,000 paired sign-flip permutations.
For all metrics, Δ is defined as Ours − Baseline. Thus, positive differences favor Ours for PCC, Spearman, and LISA, whereas negative differences favor Ours for MSE and MAE.
| Comparison | Metric | Paired samples | Mean Δ | 95% CI | p-value |
|---|---|---|---|---|---|
| Ours vs. CM-Regression | PCC-200 | 60 | +0.0086 | [0.0015, 0.0158] | 0.0237 |
| MSE | 60 | +0.0200 | [−0.0186, 0.0597] | 0.3246 | |
| MAE | 60 | −0.0051 | [−0.0207, 0.0111] | 0.5366 | |
| Spearman | 60 | +0.0084 | [0.0013, 0.0156] | 0.0272 | |
| LISA | 60 | +0.0072 | [0.0010, 0.0138] | 0.0307 | |
| Ours vs. STFlow | PCC-200 | 60 | +0.0520 | [0.0308, 0.0748] | p < 0.0001 |
| MSE | 60 | −0.0578 | [−0.1345, 0.0027] | 0.0909 | |
| MAE | 60 | −0.0092 | [−0.0339, 0.0124] | 0.4623 | |
| Spearman | 60 | +0.0486 | [0.0253, 0.0768] | p < 0.0001 | |
| LISA | 60 | +0.0253 | [0.0110, 0.0416] | 0.0009 |
The paired analysis shows that Ours improves the primary metric PCC-200 over both the architecture-matched CM-Regression baseline and STFlow, with both 95% confidence intervals excluding zero. Ours also yields positive Spearman and LISA improvements over both baselines, while the absolute-error metrics do not show conclusive differences. This sample-weighted analysis complements the across-seed standard deviations and quantifies uncertainty over the paired test slides/samples.
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 2/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper investigates what conditional flow matching contributes over endpoint regression in deterministic prediction, using histology-conditioned spatial transcriptomics as the testbed with pathology-foundation features as the condition. It proposes a minimal 4-layer x-prediction flow with gated attention, evaluates on six cancer types plus high-resolution IDC subsets, and reports best PCC across all six types over a regression baseline and STFlow, with paired significance testing and a supporting theoretical appendix.
Strengths and weaknesses
Strength:
- Rather than proposing yet another ST model, the paper isolates why a generative formulation helps, and the ablation is a clean, convincing intervention that collapses performance toward regression.
- The paper executes a careful, well-ablated diagnosis of flow matching in deterministic prediction.
- Statistical and reproducibility are illustrated clearly.
Weakness:
- The paper positions itself as a contribution to deterministic multimodal prediction in general, but all evidence comes from a single modality pairing, a single minimal architecture, and a single (linear) probability path.
- The only strong baseline is plain regression that underperforms regression in PCC on most datasets (Table 2), making it a weak point of comparison.
Questions
Can the central claim be demonstrated on at least one second deterministic multimodal task, or under a larger backbone?
Limitations
yes
Final justification
The rebuttal substantially addresses my two main concerns. In particular, the new architecture-matched CM-Regression baseline provides a considerably stronger control than the original regression baseline, and the consistent gains across three spatial-proteomics settings suggest that the observed benefit is not restricted to transcriptomic outputs. The capacity-scaling and independently implemented Qwen-style experiments also reduce the concern that the finding is an artifact of the original minimal architecture. I also appreciate that the authors narrow the claim from general deterministic multimodal prediction to histology-conditioned spatial molecular prediction, which is better aligned with the available evidence. Subject to these clarifications and inclusion of the promised details in the revision, I am inclined to raise my overall assessment from borderline reject to borderline accept.
Formatting concerns
No
1 comment
Rebuttal
We thank Reviewer 2oSA for recognizing that our paper provides a careful, well-ablated diagnosis of why a generative formulation helps in deterministic prediction, including a clean and convincing intervention that collapses performance toward regression and clearly presented statistical and reproducibility evidence. We also thank the reviewer for highlighting the limited empirical scope of the original submission. Following the reviewer’s suggestion, we expanded the evaluation along both proposed axes: (i) a second output modality through spatial-proteomics prediction and recovery, and (ii) larger and more established backbone designs. The new results extend the evidence from transcriptomics to proteomics, from spot-level to cell-level measurements, and from our minimal backbone to a Qwen-style gated transformer.
Second molecular output modality: spatial proteomics. We evaluate histology-conditioned protein-expression prediction on Visium PEX Tonsil [1], Visium PEX Pathology, which combines the glioblastoma and breast-cancer datasets [2,3], and a substantially larger CRC-CODEX cohort [4]. The two Visium PEX settings evaluate spatial recovery of 35 protein markers at spot resolution, whereas CRC-CODEX evaluates 56-marker prediction at cell resolution.
CRC-CODEX uses a strictly patient-disjoint split: all four tissue cores from each patient remain in the same partition.
| Split | Patients | Cores | Cells |
|---|---|---|---|
| Train | 21 | 84 | 124,599 |
| Test | 14 | 56 | 94,090 |
| Total | 35 | 140 | 218,689 |
All methods use the same pathology features, marker panels, normalized protein targets, and train/test partitions. We newly designed Context-Matched Endpoint Regression (CM-Regression) as a strong architecture-matched control specifically to disentangle gains from the flow objective from those due to the multi-spot gated architecture. CM-Regression uses the same context size, gated Transformer architecture, grouping strategy, data splits, and optimization protocol as Ours, but receives no noisy target-state tokens or time conditioning and directly predicts the clean endpoint using MSE. Its complete definition and transcriptomics results are provided in our responses to Reviewers zRNh and LQRt.
| Dataset | Method | Markers | Test samples | PCC ↑ | Spearman ↑ | MSE ↓ | MAE ↓ |
|---|---|---|---|---|---|---|---|
| CRC-CODEX56 | Original Regression | 56 | 94,090 | 0.1972 | 0.2148 | 3.1396 | 1.2870 |
| CM-Regression | 56 | 94,090 | 0.2029 | 0.2143 | 3.2879 | 1.2974 | |
| Ours | 56 | 94,090 | 0.2735 | 0.2797 | 3.0955 | 1.2632 | |
| Visium PEX Pathology | Original Regression | 35 | 1,985 | 0.6934 | 0.6640 | 0.2226 | 0.3116 |
| CM-Regression | 35 | 1,985 | 0.7490 | 0.7091 | 0.1624 | 0.2711 | |
| Ours | 35 | 1,985 | 0.8180 | 0.7849 | 0.1057 | 0.2140 | |
| Visium PEX Tonsil | Original Regression | 35 | 839 | 0.5631 | 0.6051 | 0.2355 | 0.2964 |
| CM-Regression | 35 | 839 | 0.6056 | 0.6378 | 0.2002 | 0.2773 | |
| Ours | 35 | 839 | 0.7028 | 0.7435 | 0.1345 | 0.2113 |
Ours consistently outperforms the architecture-matched endpoint regressor across all three protein datasets. PCC improves from 0.2029 to 0.2735 on CRC-CODEX56, from 0.7490 to 0.8180 on Visium PEX Pathology, and from 0.6056 to 0.7028 on Visium PEX Tonsil. These results show that the benefit of flow-induced target-side states is not specific to transcriptomic outputs: it transfers to spatial protein recovery at spot resolution and to large-scale spatial-proteomics prediction at cell resolution.
We additionally compare with GigaTIME-Flash [5] using the 13 protein markers shared with CRC-CODEX56. Ours achieves PCC 0.2642 and Spearman 0.2462, compared with PCC 0.0750 and Spearman 0.0555 for zero-shot GigaTIME-Flash.
Capacity scaling of the original backbone. The original architecture was intentionally kept minimal to facilitate controlled mechanistic analysis. We now increase both its hidden width and depth on IDC while keeping the input features, flow objective, data split, and evaluation protocol unchanged.
| Backbone | Hidden width | Layers | Heads | Head dimension | PCC-200 ↑ | PCC-100 ↑ | PCC-50 ↑ | MSE ↓ | MAE ↓ |
|---|---|---|---|---|---|---|---|---|---|
| Ours | 128 | 4 | 4 | 32 | 0.686 | 0.836 | 0.898 | 1.819 | 0.989 |
| Ours | 256 | 4 | 8 | 32 | 0.685 | 0.838 | 0.902 | 1.635 | 0.918 |
| Ours | 256 | 8 | 8 | 32 | 0.674 | 0.832 | 0.896 | 1.616 | 0.917 |
| Ours | 512 | 8 | 8 | 64 | 0.687 | 0.838 | 0.902 | 1.468 | 0.877 |
| Qwen-style | 128 | 4 | 4 | 32 | 0.678 | 0.835 | 0.901 | 1.504 | 0.900 |
| Qwen-style | 256 | 4 | 8 | 32 | 0.676 | 0.833 | 0.898 | 1.825 | 0.944 |
| Qwen-style | 384 | 8 | 8 | 48 | 0.682 | 0.835 | 0.899 | 1.627 | 0.905 |
Scaling our original backbone from h128-l4 to h512-l8 preserves its PCC performance while reducing MSE from 1.819 to 1.468 and MAE from 0.989 to 0.877. This shows that the formulation remains stable under substantially increased model capacity and is not tied to the minimal architecture selected for mechanistic analysis.
Transfer to a Qwen-style gated transformer. We further implement a Qwen-style gated transformer based on the gated-attention formulation of Qiu et al. [6]. Each attention layer first computes standard scaled dot-product attention and then modulates its output using a query-dependent sigmoid gate. We retain RMSNorm, SwiGLU feed-forward blocks, Q/K normalization, and gated SDPA, while adapting the causal language-model design into a bidirectional encoder over histology and molecular-state tokens. Causal masking and text-token embeddings are replaced with task-specific histology, noisy-ST-expression, and time embeddings. This is an architectural adaptation trained for our task rather than the use of pretrained Qwen language-model weights.
Across the three Qwen-style configurations, PCC-200 remains within 0.676--0.682. Scaling the h256-l4 configuration to h384-l8 improves PCC-200 from 0.676 to 0.682 while reducing MSE from 1.825 to 1.627 and MAE from 0.944 to 0.905. The stable performance under a separately implemented and more established gated-transformer design shows that our findings are not an artifact of the original minimal backbone.
The proposed mechanism also transfers across architectures. As detailed in our response to Reviewer LQRt, blocking image/spot tokens from reading noisy-ST states in the Qwen-style backbone reduces PCC from 0.6808 to 0.6481, whereas blocking the reverse direction changes PCC only to 0.6807. This reproduces the directional routing dependence observed with our original backbone and shows that the functional role of the evolving noisy target-side state is preserved after the architectural change.
Revision and scope: We will add the spatial-proteomics experiments, capacity-scaling analysis, and Qwen-style implementation to the revision, together with complete architecture, training, and evaluation details. The new evidence extends our conclusion across transcriptomic and proteomic outputs, spatial recovery and prediction settings, spot-level and cell-level measurements, and two independently implemented gated-transformer architectures. We will correspondingly narrow the broader claim to deterministic histology-conditioned spatial molecular prediction rather than universality across unrelated multimodal domains.
- Rating
- 5/6
- Confidence
- 4/5
- Quality
- 4/4
- Clarity
- 4/4
- Significance
- 4/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This manuscript studies why conditional flow matching can improve histology-conditioned spatial transcriptomics prediction when the final prediction task appears largely deterministic. The authors argue that, in this setting, the benefit of flow matching does not primarily come from generating diverse ST outputs. Instead, the noisy intermediate ST state acts as a time-indexed target-side training signal. This signal is useful only when the model can selectively extract target-relevant information while suppressing source noise and target residual variation.
To test this idea, the authors design a minimal architecture using pathology foundation model features, noisy ST tokens, multi-sample token coupling, and quadrant-wise gated self-attention. The gating mechanism controls four types of token interactions: image–image, image–ST, ST–image, and ST–ST. Through ablations, they show that flow matching alone gives limited or inconsistent improvement over regression, while the full gated model gives the best performance. They further show that repeated sampling with fixed histology input produces nearly identical outputs, supporting the view that the learned model behaves mostly deterministically.
Overall, the paper is best viewed as a mechanistic/methodological study rather than primarily a new state-of-the-art ST predictor. Its value is in asking why a generative formulation helps, not merely applying flow matching because it is fashionable.
Strengths and weaknesses
Strengths The central question is scientifically meaningful. The paper directly addresses an important conceptual tension: if histology-to-ST prediction is evaluated as a deterministic point-prediction task, why should a generative flow formulation help at all? This is a thoughtful and timely question, especially because many recent computational pathology/ST papers use diffusion or flow language without clearly testing whether sampling diversity is actually useful.
The paper’s main conceptual claim is interesting: flow matching can act as a training-time representation-learning or denoising formulation, where x_t provides structured target-side information. This reframes flow matching less as a sampler and more as a form of privileged target-side supervision during training.
The ablation design is relatively strong. The controls involving removal of x_t, permutation of x_t, removal of time embedding, vanilla self-attention, and gated self-attention are useful for testing whether the benefit comes from generic noise injection, target leakage, additional parameters, or condition-aligned target-side information.
The repeated-sampling experiment is useful and conceptually clarifying. Showing that different initial Gaussian noises lead to nearly identical outputs under the same histology condition weakens the usual “generative diversity” explanation and supports the authors’ deterministic-prediction interpretation.
The gated attention analysis is a nice diagnostic. The quadrant-wise decomposition of image–image, image–ST, ST–image, and ST–ST interactions provides a concrete way to inspect how information flows between histology tokens and noisy ST tokens.
The paper is honest in its attitude. It does not simply claim “flow matching works better”; it asks under what conditions it works and why. that is a valuable contribution.
Weakness/Concerns The empirical performance gains are consistent but modest, especially for PCC. In the controlled IDC setting, the full gated model improves PCC-200 from roughly 0.635 for regression to 0.660, and the gain over a closer gated/no-x_t or vanilla-attention control appears smaller. This is not necessarily a fatal issue, because the paper is mechanistic, but the manuscript should not present the method as a major predictive-performance breakthrough.
The role of multi-sample token coupling is not fully isolated. The proposed model processes multiple histology–ST pairs jointly, allowing cross-location context. If the regression baseline is only independent spot-wise regression, then the improvement may partly come from multi-sample context rather than the noisy flow state x_t. The authors need to clarify whether regression baselines use the same multi-sample token architecture, grouping/shuffling strategy, and inference context.
The evaluation relies heavily on PCC/MSE/MAE. These are useful, but for spatial transcriptomics they are incomplete. A model can improve point-wise correlation while failing to preserve spatial gradients, local autocorrelation, spatially variable genes, tissue domains, or niche-level structure. Since the task is spatial transcriptomics prediction, stronger spatial metrics would substantially improve the paper.
The gating interpretation is plausible but should not be overclaimed. Attention maps are diagnostic, not causal proof. The ablation results are more convincing than the attention visualizations. The manuscript should be careful to distinguish “consistent with the proposed mechanism” from “proves the mechanism.”
The term “multimodal” may be ambiguous. In one sense, the task is multimodal because it connects histology and ST. But in generative modeling, “multimodal prediction” can also mean a multimodal output distribution. Since the paper argues outputs are effectively deterministic, the authors should clarify that they are mainly referring to multimodal data/representations, not necessarily multiple output modes.
The scope should be narrowed. The results support conclusions for histology-conditioned ST prediction under the tested datasets and architecture. They do not necessarily establish a general theory of when flow matching helps deterministic multimodal prediction across all domains, output spaces, or architectures.
Questions
- Matched regression baseline with multi-sample token coupling
Please include or clarify an endpoint-regression baseline using the same multi-sample token coupling, same M-sample grouping, same gated/self-attention architecture, same parameter budget, same PFM features, and same training schedule, but without x_t and without the flow objective. This is needed to isolate whether the gain comes from flow-induced noisy target states or simply from cross-location context.
- Quantify the marginal gain of each component
Please provide a clearer decomposition of performance gains from:
multi-sample coupling, x_t, t-embedding, gating, flowloss, modelcapacity.
Right now the full model combines several mechanisms, and the attribution to target-side flow states would be stronger if the marginal contribution of each component were explicitly summarized.
- Spatial metrics
Please evaluate spatial structure preservation using metrics beyond PCC/MSE/MAE. Reasonable options include Moran’s I agreement, Geary’s C agreement, spatially variable gene recovery, local autocorrelation map similarity, neighborhood-level expression concordance, spatial domain preservation, or pathway/spatial-gradient recovery. Authors do not need to do all but at least one.
Limitations
The authors discuss some limitations, and I appreciate the mechanistic framing of the work. My main suggestion is that the limitations and broader implications should more explicitly narrow the scope of the conclusions. The results support the claim that, in the tested histology-to-spatial-transcriptomics setting, with the evaluated datasets and proposed architecture, flow matching can provide useful noisy, time-indexed target-side information during training. However, the manuscript should avoid implying that this establishes a general principle for deterministic multimodal prediction more broadly, or even for all histology-to-ST prediction settings.
In particular, the conclusions should be framed with respect to the specific prediction regime studied, including the data type, resolution, train/test setting, preprocessing, and architectural choices. This would make the contribution clearer: a thoughtful mechanistic study of why flow matching may help under these controlled ST conditions, rather than a general theory of flow matching for deterministic multimodal or spatial transcriptomics prediction.
Final justification
Thank you for the detailed response and for conducting the additional matched-control, spatial-evaluation, and routing-intervention experiments. These additions directly address my concerns and substantially clarify the attribution and scope of the conclusions. I appreciate the authors’ careful and constructive revision, and I maintain my acceptance recommendation.
Formatting concerns
no problem found
2 comments
Rebuttal
Response overview: We thank the reviewer zRNh for the constructive assessment and for framing this work as a mechanistic study. Following the suggestions, we added an architecture-matched endpoint regressor, component-level controls, spatial-autocorrelation evaluation with slide-level uncertainty, and fixed-checkpoint routing interventions. These results sharpen the attribution and scope of our conclusions.
Matched endpoint-regression control: We added Context-Matched Endpoint Regression (CM-Regression), which uses the same PFM features, gated multi-token architecture, parameter budget, grouping, splits, and training protocol as Ours, but removes noisy ST states and time conditioning and directly predicts the endpoint with MSE. We rename the PCA-Ridge model reported as “Regression” in the original submission as Original Regression.
Following the reviewer’s suggestion, we add Local Moran map similarity (LISA) to the original metrics. Dataset rows average their predefined splits, and ALL6 gives equal weight to each dataset. Ours reports mean ± standard deviation over seeds 1, 40, and 2026.
| Dataset | Method | PCC ↑ | MSE ↓ | MAE ↓ | Spearman ↑ | LISA ↑ |
|---|---|---|---|---|---|---|
| COAD | Original Regression | 0.4038 | 6.1484 | 1.9321 | 0.3896 | 0.2121 |
| STFlow | 0.4010 | 1.8582 | 0.9816 | 0.3975 | 0.2266 | |
| CM-Regression | 0.4357 | 1.8213 | 0.9843 | 0.4270 | 0.2348 | |
| Ours | 0.4591 ± 0.0198 | 1.8812 ± 0.0169 | 0.9958 ± 0.0103 | 0.4476 ± 0.0032 | 0.2475 ± 0.0038 | |
| LYMPH | Original Regression | 0.2950 | 0.8935 | 0.6735 | 0.2817 | 0.1499 |
| STFlow | 0.2615 | 0.7133 | 0.5779 | 0.2772 | 0.1237 | |
| CM-Regression | 0.3083 | 0.6711 | 0.6073 | 0.2965 | 0.1573 | |
| Ours | 0.3233 ± 0.0049 | 0.5708 ± 0.0207 | 0.5658 ± 0.0086 | 0.3092 ± 0.0058 | 0.2008 ± 0.0036 | |
| LUNG | Original Regression | 0.5832 | 5.2472 | 1.9273 | 0.5379 | 0.3649 |
| STFlow | 0.6273 | 1.1123 | 0.7955 | 0.5815 | 0.4079 | |
| CM-Regression | 0.6225 | 1.1005 | 0.7967 | 0.5733 | 0.3977 | |
| Ours | 0.6350 ± 0.0026 | 1.0741 ± 0.0313 | 0.7898 ± 0.0114 | 0.5929 ± 0.0033 | 0.4187 ± 0.0029 | |
| PAAD | Original Regression | 0.4862 | 3.0708 | 1.3694 | 0.4507 | 0.2450 |
| STFlow | 0.4852 | 0.9461 | 0.7389 | 0.4525 | 0.2493 | |
| CM-Regression | 0.4962 | 0.8509 | 0.7069 | 0.4587 | 0.2492 | |
| Ours | 0.4921 ± 0.0035 | 0.8554 ± 0.0226 | 0.6980 ± 0.0091 | 0.4635 ± 0.0024 | 0.2490 ± 0.0046 | |
| PRAD | Original Regression | 0.3021 | 1.4182 | 0.8019 | 0.2953 | 0.0789 |
| STFlow | 0.2983 | 0.6735 | 0.5779 | 0.2694 | 0.0933 | |
| CM-Regression | 0.3576 | 0.5986 | 0.5755 | 0.3440 | 0.1333 | |
| Ours | 0.3777 ± 0.0023 | 0.6297 ± 0.0143 | 0.5712 ± 0.0026 | 0.3597 ± 0.0022 | 0.1417 ± 0.0072 | |
| CCRCC | Original Regression | 0.2481 | 1.0870 | 0.7667 | 0.2419 | 0.0777 |
| STFlow | 0.2588 | 0.6266 | 0.5880 | 0.2743 | 0.0803 | |
| CM-Regression | 0.2827 | 0.6038 | 0.6040 | 0.2780 | 0.0833 | |
| Ours | 0.3140 ± 0.0030 | 0.5888 ± 0.0043 | 0.5895 ± 0.0049 | 0.3033 ± 0.0014 | 0.0865 ± 0.0041 | |
| ALL6 macro | Original Regression | 0.3864 | 2.9775 | 1.2451 | 0.3662 | 0.1881 |
| STFlow | 0.3887 | 0.9883 | 0.7100 | 0.3754 | 0.1969 | |
| CM-Regression | 0.4172 | 0.9410 | 0.7125 | 0.3963 | 0.2093 | |
| Ours | 0.4335 | 0.9333 | 0.7017 | 0.4127 ± 0.0025 | 0.2240 ± 0.0017 |
Relative to CM-Regression, Ours improves ALL6 PCC from 0.4172 to 0.4335, Spearman from 0.3963 to 0.4127, and LISA from 0.2093 to 0.2240. We agree that these gains are moderate; we claim a consistent mechanistic benefit rather than a major performance breakthrough.
Component attribution and routing evidence: Context-size experiments separate multi-token coupling from the flow formulation. At , Ours/CM-Regression obtain PCC-200 of 0.627/0.655; the ordering reverses at (0.658/0.640) and remains positive at (0.660/0.643). Local sampling further enlarges the gap to 0.686/0.626. Due to space constraints, the complete PCC-200/100/50 sensitivity and global-versus-local sampling table is provided in the Context-size sensitivity and spatial context section of our response to Reviewer LQRt. These results show that the shared multi-token architecture alone does not explain the improvement; the benefit emerges when context is combined with evolving target-side states.
The requested components are controlled as follows: varying tests multi-sample coupling; CM-Regression compares the complete flow formulation with endpoint MSE; the original no-, permuted-, and no-time ablations test the presence, pairing, and temporal interpretation of the intermediate state; vanilla versus gated attention tests selective integration; and matched architectures control capacity. Scaling and Qwen-style results reported to Reviewer 2oSA further establish architecture stability. Because these components interact structurally, we interpret the interventions jointly rather than as additive effects.
We additionally intervene on fixed checkpoints to move beyond diagnostic attention maps. Blocking target-to-image/spot routing reduces PCC from 0.6864 to 0.6448, whereas blocking the reverse route changes it only to 0.6846. Qwen-style attention reproduces this directionality: 0.6808 to 0.6481 versus 0.6807 under the reverse intervention. The complete intervention table is provided in the Empirical test of the idealized theoretical mechanism section of our response to Reviewer LQRt. Thus, training-time ablations identify the components required for learning, while inference-time intervention shows that the trained predictor functionally uses target-to-image routing. We will therefore present attention maps as diagnostic rather than causal evidence.
Spatial-structure preservation: For each gene and slide, we compute ground-truth and predicted Local Moran statistics using the same within-slide graph and correlate the resulting LISA maps. Ours achieves 0.2240 versus 0.2093 for CM-Regression, 0.1969 for STFlow, and 0.1881 for Original Regression.
| Comparison | ΔLISA | 95% CI | p-value |
|---|---|---|---|
| Ours − CM-Regression | +0.0072 | [0.0010, 0.0138] | 0.0307 |
| Ours − Original Regression | +0.0358 | [0.0243, 0.0480] | p < 0.0001 |
| Ours − STFlow | +0.0253 | [0.0110, 0.0416] | 0.0009 |
CIs use 20,000 paired slide-level bootstrap resamples; p-values use 20,000 paired sign-flip permutations. The main table uses dataset-level macro-averaging, whereas inference uses paired slides, explaining the different effect sizes.
Positioning and revision: We will clarify that “multimodal” refers to histology and spatial molecular data, not multiple output modes, and position the paper as an analysis-driven mechanistic study. With the added proteomics and Qwen-style experiments, we limit the claim to deterministic histology-conditioned spatial molecular prediction under the evaluated settings. We will add CM-Regression, LISA uncertainty, context analyses, and routing interventions; reorganize the component ablations; and revise the attention interpretation and scope accordingly.
Thank you for the detailed response and for conducting the additional matched-control, spatial-evaluation, and routing-intervention experiments. These additions directly address my concerns and substantially clarify the attribution and scope of the conclusions. I appreciate the authors’ careful and constructive revision, and I maintain my acceptance recommendation.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
We thank the Area Chair 9JVh for the careful synthesis of the reviews. Detailed experimental results and implementation settings are provided in the reviewer-specific rebuttals and follow-up comments. Here, we summarize how these additions collectively address the main issues identified in the meta-review.
The first issue was whether the gain could be attributed specifically to flow-induced target states rather than model capacity or additional multi-token computation. We addressed this with CM-Regression, an endpoint regressor matched to our model in architecture, context, parameter budget, data splits, and training protocol. The context-size experiments show that CM-Regression is stronger when samples are processed independently, while the flow model becomes stronger when contextual interaction is available. Together with the original state-removal, state-permutation, no-time, and gating ablations, this separates the effect of the flow-induced states from that of simply using a larger contextual model. Fixed-checkpoint routing interventions further show that the trained model depends specifically on the route from the evolving target-side state to the histology representation. The same directional effect appears in the independently implemented Qwen-style backbone, providing an empirical connection between the idealized analysis and the behavior of the trained predictor.
The second issue concerned uncertainty and spatial coherence. We added multi-seed results for the main neural baselines, paired slide-level bootstrap confidence intervals and permutation tests across the six transcriptomic datasets, and Local Moran map similarity. These analyses support the improvements in both predictive correlation and spatial-structure preservation. We agree that the gains over the matched regressor are consistent but moderate, and therefore position the paper as a mechanistic study rather than a major performance breakthrough.
The final issue was empirical scope. We extended the evaluation from transcriptomics to three spatial-proteomics settings and from the original minimal architecture to a Qwen-style gated backbone. These experiments test whether the matched-control advantage extends across molecular output types, spatial resolutions, and model implementations. We recognize that this does not establish generality across unrelated multimodal domains, and we will accordingly narrow the claim to deterministic histology-conditioned spatial molecular prediction under the evaluated settings.
We thank the Area Chair and reviewers for the careful feedback, which has helped us substantially strengthen the paper. We believe the revised work provides a useful explanation of when and why conditional flow matching can offer an advantage over endpoint regression, and we would appreciate the opportunity to share these findings with the NeurIPS community.