Magnetic Resonance Unpaired Image Translation with Pseudometric Schrödinger Bridges
Shuwen Wei, Samuel W. Remedios, Zhangxing Bian, Shimeng Wang, Jinwei Zhang, Junyu Chen, Yihao Liu, Lianrui Zuo, Muhammad Faizyab Ali Chaudhary, Blake E. Dewey, Aaron Carass, Jerry L Prince
NeurIPS 2026
TL;DR. We propose the pseudometric Schrödinger bridge (PMSB) that translates magnetic resonance images across different contrasts while preserving the underlying anatomy.
Abstract. Unpaired image translation is a critical preprocessing strategy for synthesizing missing sequences and harmonizing contrast variability in magnetic resonance imaging (MRI). However, in medical image processing, distribution-level translation is insufficient. It is vitally important that the anatomy is not distorted, corrupted, or lost after translation. Previous methods, like diffusion Schrödinger bridge matching (DSBM), achieve unpaired image translation, but do not preserve anatomy. We introduce the pseudometric Schrödinger bridge (PMSB), which trains two independent volume-preserving, isometry-regularized diffeomorphisms to map data from each domain to a latent anatomical pseudometric space. Then, DSBM is used within that space, explicitly minimizing the transport gap while preserving anatomy. Extensive experiments on the multi-contrast OASIS-3 dataset demonstrate that PMSB establishes a new state-of-the-art in structural consistency for cross-contrast synthesis. PMSB outperforms other leading methods and drastically reduces anatomical hallucinations, notably yielding a mean PSNR of 26.70 dB, a mean SSIM of 0.86, and a mean LNCC of 0.24.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:45 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
The paper introduces Pseudometric Schrödinger Bridge (PMSB) for unpaired MR image translation, which learns two independent volume‑preserving diffeomorphisms to map different contrasts into a shared latent pseudometric space before applying diffusion Schrödinger bridge matching. Reviewers agreed the framework is mathematically rigorous and achieves structural preservation, but raised important concerns. For example, the novelty is incremental compared to LMSB, the experimental scope is narrow (only 2D brain MRI, pre‑registered data, limited pathology/generalization), the method relies on additional anatomical supervision that may give it an unfair advantage, and computational cost and robustness are not reported. In the rebuttal phase, the authors responded to the concerns on novelty, fairness, computational cost, and additionally evaluate on more datasets. Two reviewers are mostly satisfied with the responses, and the remaining one reviewer raised score to 3, still having concerns on novelty and required revisions in writing. Overall, AC acknowledge the fundamental idea of introducing segmentation map as latent and designing the translation bridge by mapping two domains to the latent domain first, and the results demonstrate apparent improvements in comparisons. Though the idea is a combination of techniques such as segmentation/Schrödinger Bridge/invertible network, this solution to solve unpaired MRI translation is interesting and reasonable considering the requirement of anatomy-preservation in medical image translation. Overall, the strengths overweigh the limitations, and the authors should carefully revise the manuscript considering the reviewers' concerns in the final version.
Final justification
The submission initially received mixed ratings. In the rebuttal phase, the authors responded to the concerns on novelty, fairness, computational cost, and additionally evaluate on more datasets. Two reviewers are mostly satisfied with the responses, and the remaining one reviewer raised score to 3, still having concerns on novelty and required revisions in writing. Overall, AC acknowledge the fundamental idea of introducing segmentation map as latent and designing the translation bridge by mapping two domains to the latent domain first, and the results demonstrate apparent improvements in comparisons. Though the idea is a combination of techniques such as segmentation/Schrödinger Bridge/invertible network, this solution to solve unpaired MRI translation is interesting and reasonable considering the requirement of anatomy-preservation in medical image translation. Overall, the strengths overweigh the limitations, and the authors should carefully revise the manuscript considering the reviewers' concerns in the final version.
Read meta-review
Meta-review
The paper introduces Pseudometric Schrödinger Bridge (PMSB) for unpaired MR image translation, which learns two independent volume‑preserving diffeomorphisms to map different contrasts into a shared latent pseudometric space before applying diffusion Schrödinger bridge matching. Reviewers agreed the framework is mathematically rigorous and achieves structural preservation, but raised important concerns. For example, the novelty is incremental compared to LMSB, the experimental scope is narrow (only 2D brain MRI, pre‑registered data, limited pathology/generalization), the method relies on additional anatomical supervision that may give it an unfair advantage, and computational cost and robustness are not reported. In the rebuttal phase, the authors responded to the concerns on novelty, fairness, computational cost, and additionally evaluate on more datasets. Two reviewers are mostly satisfied with the responses, and the remaining one reviewer raised score to 3, still having concerns on novelty and required revisions in writing. Overall, AC acknowledge the fundamental idea of introducing segmentation map as latent and designing the translation bridge by mapping two domains to the latent domain first, and the results demonstrate apparent improvements in comparisons. Though the idea is a combination of techniques such as segmentation/Schrödinger Bridge/invertible network, this solution to solve unpaired MRI translation is interesting and reasonable considering the requirement of anatomy-preservation in medical image translation. Overall, the strengths overweigh the limitations, and the authors should carefully revise the manuscript considering the reviewers' concerns in the final version.
Final justification
The submission initially received mixed ratings. In the rebuttal phase, the authors responded to the concerns on novelty, fairness, computational cost, and additionally evaluate on more datasets. Two reviewers are mostly satisfied with the responses, and the remaining one reviewer raised score to 3, still having concerns on novelty and required revisions in writing. Overall, AC acknowledge the fundamental idea of introducing segmentation map as latent and designing the translation bridge by mapping two domains to the latent domain first, and the results demonstrate apparent improvements in comparisons. Though the idea is a combination of techniques such as segmentation/Schrödinger Bridge/invertible network, this solution to solve unpaired MRI translation is interesting and reasonable considering the requirement of anatomy-preservation in medical image translation. Overall, the strengths overweigh the limitations, and the authors should carefully revise the manuscript considering the reviewers' concerns in the final version.
1 comment
- Rating
- 3/6
- Confidence
- 5/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 2/4
- Originality
- 2/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper improves Latent Metric Schrödinger Bridge (LMSB) for unpaired MRI translation. The motivation is that directly training DSBM between two MRI domains can induce anatomically incorrect transport due to differences in intensity distributions. LMSB addresses this by mapping images into a latent space where the intensity distributions are more similar before training DSBM. This paper points out a limitation of LMSB: the latent mapping network is shared across the two domains. The authors argue that learning separate mappings for each domain can further reduce the distance between the transformed domains. Empirically, the proposed method achieves generally strong performance compared with prior methods, especially in similarity metrics such as SSIM and PSNR.
Strengths and weaknesses
[Strengths]
- The paper provides a clear background discussion and presents the method with mathematically rigorous assumptions and notation.
- The quantitative results show notable improvements over existing baselines, especially over LMSB in some experimental settings.
- The core motivation is reasonable: since LMSB uses an invertible shared network, images with the same anatomy but different contrasts cannot theoretically be mapped to exactly the same latent point.
[Weaknesses]
- While the above motivation is theoretically valid, it does not fully explain why learning two separate domain-specific mappings should practically map the two domains to closer latent representations than using a shared mapping. In addition, the outputs shown in Fig. 6 do not visually appear highly similar across domains. LMSB also acknowledges that mapping images with the same anatomy but different contrasts to exactly the same point is an idealized goal, and instead aims to reduce the distance as much as possible. Therefore, although the one-to-one nature of an invertible function makes exact many-to-one mapping impossible in theory, it is unclear whether this theoretical distinction has substantial practical significance here. It is also unclear whether the proposed domain-specific mappings are inherently more likely to produce closer latent representations than a shared mapping.
- The technical contribution appears limited: the method largely follows the LMSB pipeline, with the main modification being that the latent mapping networks are trained separately for the two domains.
- The writing could be improved. In the introduction, the practical difference between the previous method and the proposed method is not made sufficiently clear. The paper spends substantial space on theoretical interpretation before clearly explaining what is actually changed in the method. The concrete implementation only becomes clear later in the Experiments section. Presenting the practical algorithmic change earlier would make the paper easier to follow.
Questions
- The paper should more clearly justify why the proposed independent mapping strategy is expected to reduce the distribution gap more effectively than a shared mapping. Simply stating that an invertible shared mapping cannot perform many-to-one mapping is not sufficiently convincing. It is also possible that a shared mapping may preserve more similar details across domains.
- It would be helpful to show a direct visual comparison between the latent outputs produced by LMSB’s shared mapping and those produced by the proposed independent mappings. This would help verify whether the proposed method actually reduces the inter-domain gap in the latent space.
- In Table 1, the proposed method performs similarly to LMSB for T1-FLAIR translation, but shows a very large improvement for T1-T2 translation. Similarly, in the first row of Fig. 7, the LMSB result for T1-T2 appears to fail noticeably, whereas the T1-FLAIR results look visually similar. The paper explains this by saying that the T1-T2 domain gap is larger, but this explanation would be more convincing if the authors showed that LMSB indeed produces less aligned latent outputs for T1-T2.
Limitations
yes
Final justification
Thank you for the detailed rebuttal. The new direct comparison between LMSB and PMSB resolves my main concern about whether PMSB actually reduces the inter-domain latent distance more effectively in practice.
However, the methodological novelty remains quite incremental and does not fundamentally change the underlying mechanism. The paper also appears to require substantial structural revision to improve the clarity and presentation of the method. Considering both the strengthened empirical evidence and these remaining concerns, I will raise my score to borderline reject and my confidence to 5.
Formatting concerns
The proposed method differs from LMSB by a relatively small implementation change: replacing the shared latent mapping with domain-specific mappings. However, the key rationale supporting this change—that independent mappings produce more similar latent representations than a shared mapping—is not sufficiently convincing. I would be more positive about the submission if this central claim were better justified, either theoretically or through more direct empirical evidence.
3 comments
Rebuttal
We thank the reviewer for the constructive comments and for highlighting that the central claim needs stronger support. We address this both theoretically and with new empirical evidence on the latent gap.
1. Why should independent maps reduce the distribution gap more than a shared map?
Theoretically, the residual transport cost after mapping is controlled by the latent-gap objective in Eq. 3. The shared-map family used by LMSB is a strict subset of the independent-map family used by PMSB; minimizing the same objective over a larger set yields a residual gap that is smaller or equal.
Practically, this predicts a smaller inter-domain latent distance for PMSB than LMSB, as we show with direct empirical evidence next.
2. Direct latent comparison between LMSB and PMSB
We computed mean squared distance between 1,020 testing pairs in image space and after LMSB/PMSB mappings as follows.
| Metric | Task | Original MR | LMSB latent | PMSB latent |
|---|---|---|---|---|
| MSE ×1000 | T1w ↔ T2w | 52.22 ± 11.87 | 16.72 ± 2.73 | 13.31 ± 2.79 |
| T1w ↔ FLAIR | 15.58 ± 3.79 | 8.28 ± 1.24 | 8.00 ± 1.23 |
PMSB latents are closer across domains than LMSB latents on both tasks. The absolute reduction is larger on T1w↔T2w (16.72→13.31) than on T1w↔FLAIR (8.28→8.00), where LMSB already achieves strong alignment. This provides direct empirical support that independent maps in PMSB reduce the inter-domain latent gap more than a shared mapping in LMSB. Visual comparison of LMSB and PMSB latents will be provided in the final paper.
3. Why is T1w↔T2w improved much more than T1w↔FLAIR?
The same latent-gap measurements in the table above explain the asymmetric gains. T1w↔T2w starts with a much larger image-space gap (52.22 vs 15.58) and a larger LMSB latent gap (16.72 vs 8.28). Consequently, relaxing the shared-map constraint to independent maps provides more improvement on the T1w↔T2w translation task.
4. Incremental contribution
We acknowledge that PMSB is a natural extension of LMSB by relaxing the shared mapping constraint. We argue this relaxation is practically important, because on large-gap T1w↔T2w translation, PMSB substantially outperforms LMSB as shown in Table 1 and Fig. 7.
Beyond the algorithmic change, the paper contributes a more fundamental pseudometric formulation with supporting theory, a stricter evaluation on paired ground-truth structural metrics, and a broader comparison with baseline methods than in the LMSB paper.
5. On the writing
We agree and will move the practical algorithmic distinction earlier in the introduction, so the difference from LMSB is clear before the theoretical development.
Thank you for the detailed rebuttal. The new direct comparison between LMSB and PMSB resolves my main concern about whether PMSB actually reduces the inter-domain latent distance more effectively in practice.
However, the methodological novelty remains quite incremental and does not fundamentally change the underlying mechanism. The paper also appears to require substantial structural revision to improve the clarity and presentation of the method. Considering both the strengthened empirical evidence and these remaining concerns, I will raise my score to borderline reject and my confidence to 5.
Thank you for your continued engagement and for acknowledging that our new empirical evidence effectively resolves the primary concern regarding the inter-domain latent distance. We would like to take this opportunity to address your remaining points regarding the paper's presentation and novelty:
Presentation: We appreciate your feedback on clarifying the practical differences earlier in the text. While the concrete implementation details are naturally finalized in the Experiments section, we respectfully note that Section 3.1 and Figure 2 do establish the algorithmic framework using independent mappings ( and ) early in the methodology. Nonetheless, we agree that explicitly stating this in the Introduction will improve readability. Our introduction currently highlights "generalizing the latent metric space into a pseudometric space". To immediately ground this theoretical concept in its practical algorithmic change, we will add the phrase "(i.e., replacing a shared mapping with independent mappings)" directly to this sentence. We believe this minor addition clarifies the practical implementation upfront without requiring substantial structural revisions.
Contribution: Regarding novelty, while the resulting architectural change is straightforward, our primary contribution lies in the rigorous theoretical foundation that justifies it. The LMSB paper motivates the problem intuitively from a differential geometry perspective. In contrast, PMSB formulates a strict set of geometrical assumptions: deterministic coupling, diffeomorphism, volume preservation, and approximate isometry. From there, we derive the theory strictly from an optimal transport perspective, proving the validity of our learning objective under these assumptions. These theoretical advancements, combined with the mathematical generalization to a pseudometric space, represent a fundamental contribution that goes significantly beyond the prior work.
We sincerely appreciate your time and constructive critique, which have helped us strengthen both the empirical validation and final presentation of this work. Please let us know if you have any remaining concerns; we would be grateful for the opportunity to provide further clarification.
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 2/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper proposes the Pseudometric Schrödinger Bridge (PMSB) for unpaired MR image translation. The key idea is to learn two independent volume-preserving, approximately isometric diffeomorphisms that map images from each contrast domain into a shared latent space where anatomy is aligned but contrast is stripped. Diffusion Schrödinger Bridge Matching (DSBM) is then applied within this latent space for the actual translation. The approach is evaluated on the OASIS-3 dataset across two settings (T1↔T2, T1↔FLAIR) and achieves structural consistency metrics (PSNR, SSIM, LNCC) better than the methods that it was compared against.
Strengths and weaknesses
Strengths
Theoretically principled framework. The paper provides a clean mathematical narrative from the problem formulation through geometric assumptions, to the derivation of the unpaired upper-bound objective, and the isometry regularization via noise injection. The progression is logical and each assumption is motivated by the medical imaging context. Strong structural preservation results. PMSB dramatically outperforms all baselines on structural metrics for the T1↔T2 setting (the harder task with larger domain gap): e.g., SSIM of 88.71% vs. next-best ContourDiff at 82.38% for T1→T2. The qualitative results (Fig. 7) convincingly show reduced anatomical hallucination.
Well-motivated architecture choices. Using normalizing flow-based affine coupling layers to architecturally guarantee volume preservation (det = 1 by construction) is an interesting design choice.
Weaknesses
Training on pre-registered data undermines claims of translation independence. All data is rigidly registered to MNI space and inter-modality co-registered before the train/test split. While the paper correctly constructs an unpaired setting by splitting subjects between domains, the spatial alignment means the model never encounters the geometric variability present in truly unregistered multi-site data.
The paper's theoretical framework emphasizes domain independence and the ability to handle arbitrary geometric relationships between domains, yet the experimental setting pre-solves the spatial alignment problem. It is unclear how much of PMSB's advantage stems from the pseudometric formulation versus the simplified, pre-aligned input space. Also, the paper motivates unpaired translation by stating "perfectly registered paired scans are scarce" given that rigid registration to MNI in the experiment, the practical motivation for unpaired methods is weakened. The paper should clarify: is the method designed for settings where registration is unavailable, or where pairs are unavailable but registration is possible?
The PMSB uses additional anatomical supervision can be considered an unfair advantage over other methods. PMSB and LMSB train diffeomorphisms using SynthSeg segmentation maps as regression targets — an additional source of anatomical supervision. In contrast, SynDiff, ContourDiff, UNSB, and DSBM operate without any segmentation signal. The comparison in Table 1 thus conflates two factors: (a) the benefit of the pseudometric/OT framework, and (b) the benefit of segmentation-based anatomical guidance. This should at least be highlighted more in the comparison table.
Somewhat Limited experimental scope. The evaluation uses OASIS-3 (brain MRI with different MRI sequences for Alzheimer’s subjects). While OASIS-3 offers a large cohort (402 subjects), comparable methods like SynDiff demonstrate their approach on three datasets including BraTS (brain glioma patients with tumors causing non-trivial anatomical changes) and pelvic MRI-CT (true cross-modality translation). I acknowledge that OASIS-3 provides more samples than BraTS/IXI/pelvic datasets, but diversity of evaluation settings is important to establish generalizability.
Computational cost not reported. Training two diffeomorphism networks plus DSBM (30 IMF steps × thousands of iterations) is likely to more expensive than baselines. No training time, inference time, or GPU memory comparisons are provided.
Questions
- Can the authors provide experimental support that their method will work with data that are not registered? Or alternative modify the claims?
- Pathological anatomy/experimental scope. Can the authors expand the experimental scope by expanding to subjects with more significant anatomical changes like in brain datasets like BRATS which anatomical changes are induced by tumors. Alternatively, can the authors include other modality transformations in other parts of the body e.g. with the pelvic datasets used in the SynDiff paper? I acknowledge that these datasets are substantially smaller, so results may be noisier, but the goal here is demonstrating some generalizability across pathology types and anatomical regions, not necessarily achieving state-of-the-art on each.
- Computational cost: What is the total wall-clock training time (diffeomorphisms + DSBM), and what is the per-slice inference time? How do these compare to baselines trained under equivalent hardware? This is essential for assessing practical deployability.
- It would be interesting to disentangle the anatomical segmentation maps from the method to see how it compares with other methods that do not require it (as it is challenging to get for many medical imaging application), but I do realize that key components of the proposed approach are built around these segmentation maps, so it could not be possible without changing the nature of the method presented.
Limitations
yes
Formatting concerns
no concerns
1 comment
Rebuttal
We thank the reviewer for the positive and constructive feedback. We respond to each point below.
1. Registered data vs unpaired claims
Our intended setting is unpaired image translation when paired supervision is unavailable, while standard spatial preprocessing remains allowed. MNI alignment in the paper is standard neuroimaging practice, not a claim that PMSB requires a common template. To test sensitivity of PMSB to template alignment, we retrained PMSB on T1w↔T2w translation without registering volumes to the MNI template. We used the same 402 paired sessions and the same training/validation/testing subject split. The comparison results are shown as follows.
| Metric | Task | With MNI (original) | No MNI |
|---|---|---|---|
| PSNR ↑ | T1w → T2w | 25.03 ± 1.34 | 25.11 ± 1.42 |
| T2w → T1w | 27.20 ± 2.04 | 24.71 ± 2.37 | |
| SSIM ↑ | T1w → T2w | 88.71 ± 2.14 | 89.63 ± 1.96 |
| T2w → T1w | 90.88 ± 1.66 | 87.23 ± 2.15 | |
| LNCC ↑ | T1w → T2w | 27.87 ± 2.45 | 28.74 ± 3.01 |
| T2w → T1w | 30.83 ± 2.57 | 27.65 ± 2.78 | |
| FID ↓ | T1w → T2w | 33.23 | 19.07 |
| T2w → T1w | 21.42 | 42.34 |
Due to different head orientation of each volume, the new extracted axial slices are different from those extracted from aligned volumes, so the training/validation/testing datasets are also different from the old ones. Nonetheless, we see a comparable performance without MNI alignment, where the T1w→T2w translation is slightly better and the T2w→T1w translation shows a moderate drop.
2. Limited experimental scope and generalizability
We agree that broader evaluation is important to demonstrate generalizability. Beyond OASIS-3, which already includes Alzheimer’s-spectrum subjects, we additionally evaluated T1w↔T2w translation on BraTS20, which has more substantial tumor-induced anatomical deformation. Specifically, we split 369 subjects from BraTS20 into disjoint sets of 304 training, 32 validation, and 33 testing subjects. Each subject has paired T1w and T2w scans and we extracted 33 axial slices from each MR volume, yielding 5,016 unpaired training slices, 528 validation slices, and 1,089 testing slices. For PMSB, the segmentation target was constructed through SynthSeg and tumor labels. We compared the performance of PMSB with SynDiff and DSBM. The results on the 1,089 testing pairs are summarized as follows.
| Metric | Task | SynDiff | DSBM | PMSB |
|---|---|---|---|---|
| PSNR ↑ | T1w → T2w | 19.79 ± 1.33 | 16.19 ± 1.35 | 21.12 ± 1.55 |
| T2w → T1w | 20.22 ± 0.83 | 15.33 ± 1.12 | 21.12 ± 1.20 | |
| SSIM ↑ | T1w → T2w | 75.94 ± 2.38 | 56.08 ± 4.82 | 83.33 ± 2.91 |
| T2w → T1w | 77.31 ± 1.67 | 51.93 ± 5.39 | 83.85 ± 2.15 | |
| LNCC ↑ | T1w → T2w | 13.12 ± 2.54 | 19.29 ± 2.52 | 21.56 ± 2.93 |
| T2w → T1w | 16.16 ± 2.44 | 19.15 ± 2.58 | 23.47 ± 2.75 | |
| FID ↓ | T1w → T2w | 36.74 | 49.55 | 55.74 |
| T2w → T1w | 70.04 | 72.03 | 53.56 |
We can see that PMSB achieves the best PSNR/SSIM/LNCC on both directions, while FID remains mixed. This supports generalization of PMSB under pathological anatomy. We acknowledge remaining limits (e.g., other anatomies, cross-modality) and will expand evaluation further in the future.
3. Computational cost
Each method was trained and tested on one GPU with 48 GB VRAM. We summarize the overall training time and per-slice inference time (including disk I/O etc) as follows.
| Metric | SynDiff | ContourDiff | UNSB | DSBM | LMSB | PMSB |
|---|---|---|---|---|---|---|
| Sampler | default | default | default | sde / ode | sde / ode | sde / ode |
| Train (h) | 55.8 | 33.0 | 75.7 | 39.5 | 47.8 | 56.0 |
| Infer (s/slice) | 0.24 | 1.42 | 3.15 | 4.95 / 12.87 | 4.90 / 12.51 | 4.89 / 12.41 |
We note that ContourDiff and UNSB need to be trained per translation direction and thus the effective training time needs to be doubled. Other methods work on both translation directions with one training.
4. Anatomical supervision provides unfair advantage?
We note that ContourDiff also uses anatomical structure via edge maps, so it is not a segmentation-free baseline. Therefore, the comparison between ContourDiff and PMSB shows the benefit of the OT framework (to some degree); the comparison between DSBM and LMSB/PMSB shows the benefit of segmentation-based anatomical guidance; and the comparison between LMSB and PMSB shows the benefit of the pseudometric framework. We will highlight this more in the comparison table.
5. Disentangle segmentation from the method
We agree that a fully segmentation-free variant would change the nature of the method. In our framework, the segmentation map is a practical proxy for the latent anatomical target , used so that and can be learned from unpaired data via Eq. 4 rather than the paired objective in Eq. 3. It is one of several design choices that make the unpaired formulation trainable, not an optional add-on that can be removed while leaving PMSB otherwise unchanged. Developing a competitive segmentation-free alternative would require additional theoretical and engineering work; we leave that to future research.
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only, CLEAR MAJOR CONCERN: Check this box if there is a clear, major concern for which you do not need further clarifications. Detail the concern in the Strengths and Weaknesses section. Use another option below if you would benefit from a consultation with an expert., Major Concern: Improper research involving human subjects, Major Concern: Data privacy, copyright, and consent, Major Concern: Data quality and representativeness, Major Concern: Safety and security, Major Concern: Discrimination, bias, and unfairness, Major Concern: Deception and harassment, Major Concern: Environmental impact, Major Concern: Human rights (including surveillance)
Read review
Summary
This work addresses the challenge of maintaining anatomical fidelity in unpaired MR image translation. Building on the latent metric Schrödinger bridge (LMSB), it proposes PMSB, which learns two independent volume-preserving diffeomorphisms to map images into a shared latent pseudometric space, then applies DSBM for translation to reduce the transport gap while preserving anatomy. The method is backed by complete theoretical proofs and geometrical constraints. Experiments on OASIS-3 show PMSB achieves state-of-the-art structural consistency on T1↔T2 and T1↔FLAIR tasks. The claims of the paper — that relaxing a strict metric space to a pseudometric space improves structural preservation — are largely validated by results.
Strengths and weaknesses
Strengths
-
Rigorous theoretical framework with formal assumptions and complete mathematical proofs
-
Design aligns with clinical priorities, using volume preservation and isometry regularization to reduce anatomical distortion
3.Comprehensive baseline comparison, with clear quantitative and visual improvements on large-domain-gap tasks
Weaknesses
-
Novelty is incremental: the core idea is a natural extension of LMSB by relaxing the shared mapping constraint
-
Narrow experimental scope: only validated on 2D brain MRI from one dataset, no 3D or cross-anatomy generalization tests
-
Unquantified computational cost, and no robustness analysis for segmentation errors
Questions
-
How does degradation of segmentation quality affect the final translation performance?
-
Why is the improvement on T1↔FLAIR far smaller than on T1↔T2? Is the pseudometric benefit correlated with domain gap size?
Limitations
-
Only validated on 2D brain MRI, generalizability to other regions or pathologies is unproven
-
Performance depends on the quality of auxiliary segmentation tools
-
Multi-stage training and inference overhead is not quantified
-
Trades target-domain distribution fidelity (FID) for structural accuracy
Final justification
I keep the initial rating unchanged after considering the rebuttal.
Formatting concerns
no
1 comment
Rebuttal
We thank the reviewer for the positive comments. We respond to each question and limitation as follows.
1. Robustness to segmentation quality
We evaluated sensitivity to segmentation quality by degrading SynthSeg targets and retraining both the diffeomorphisms and the bridge for PMSB. Specifically, we dilated the white-matter label with radius r=1 and r=2, retrained PMSB with degraded targets, and then compared translation performance to PMSB trained with the original SynthSeg maps. The results on the 1,020 testing pairs are summarized as follows.
| Metric | Task | SynthSeg (original) | WM dilate r=1 | WM dilate r=2 |
|---|---|---|---|---|
| PSNR ↑ | T1w → T2w | 25.03 ± 1.34 | 24.74 ± 1.33 | 24.32 ± 1.19 |
| T2w → T1w | 27.20 ± 2.04 | 26.96 ± 1.95 | 26.77 ± 1.72 | |
| SSIM ↑ | T1w → T2w | 88.71 ± 2.14 | 88.31 ± 1.99 | 87.74 ± 2.01 |
| T2w → T1w | 90.88 ± 1.66 | 90.40 ± 1.73 | 90.13 ± 1.63 | |
| LNCC ↑ | T1w → T2w | 27.87 ± 2.45 | 27.37 ± 2.42 | 26.88 ± 2.37 |
| T2w → T1w | 30.83 ± 2.57 | 30.33 ± 2.53 | 30.03 ± 2.47 | |
| FID ↓ | T1w → T2w | 33.23 | 25.35 | 27.20 |
| T2w → T1w | 21.42 | 22.33 | 24.36 |
We can see that structural metrics degrade only mildly as segmentation quality degrades. Even under dilation, PMSB still outperforms other comparison methods on the same OASIS-3 task in Table 1.
Moreover, robustness to segmentation quality can be seen from Fig. 6, where SynthSeg does not capture all fine anatomical details (Fig. 6, Targets), but these structures remain well-preserved in the mapped outputs (Fig. 6, Outputs) when compared with the inputs (Fig. 6, Inputs).
These results suggest robustness to moderate segmentation errors, while we still acknowledge dependence on auxiliary segmentation quality as a limitation.
2. Why is T1w↔FLAIR improvement smaller than T1w↔T2w? Is the pseudometric benefit correlated with domain gap?
Yes, the pseudometric benefit correlates with the latent domain gap, i.e., the residual transport cost controlled by Eq. 3. To demonstrate that, we computed mean squared distance between 1,020 testing pairs in image space and after LMSB/PMSB latent mappings as follows.
| Metric | Task | Original MR | LMSB latent | PMSB latent |
|---|---|---|---|---|
| MSE ×1000 | T1w ↔ T2w | 52.22 ± 11.87 | 16.72 ± 2.73 | 13.31 ± 2.79 |
| T1w ↔ FLAIR | 15.58 ± 3.79 | 8.28 ± 1.24 | 8.00 ± 1.23 |
T1w↔T2w has a much larger image-space gap than T1w↔FLAIR (52.22 vs 15.58). LMSB reduces both, but leaves a larger latent domain gap on T1w↔T2w (16.72 vs 8.28). PMSB reduces this latent domain gap further, with a larger absolute gain on T1w↔T2w (16.72→13.31) than on T1w↔FLAIR (8.28→8.00), where LMSB is already well aligned. This explains why Table 1 shows large PMSB vs LMSB improvements on T1w↔T2w and only small gains on T1w↔FLAIR.
3. Limited experimental scope and generalizability
We agree that broader evaluation is important to demonstrate generalizability. Beyond OASIS-3, which already includes Alzheimer’s-spectrum subjects, we additionally evaluated T1w↔T2w translation on BraTS20, which has more substantial tumor-induced anatomical deformation. Specifically, we split 369 subjects from BraTS20 into disjoint sets of 304 training, 32 validation, and 33 testing subjects. Each subject has paired T1w and T2w scans and we extracted 33 axial slices from each MR volume, yielding 5,016 unpaired training slices, 528 validation slices, and 1,089 testing slices. For PMSB, the segmentation target was constructed through SynthSeg and tumor labels. We compared the performance of PMSB with SynDiff and DSBM. The results on the 1,089 testing pairs are summarized as follows.
| Metric | Task | SynDiff | DSBM | PMSB |
|---|---|---|---|---|
| PSNR ↑ | T1w → T2w | 19.79 ± 1.33 | 16.19 ± 1.35 | 21.12 ± 1.55 |
| T2w → T1w | 20.22 ± 0.83 | 15.33 ± 1.12 | 21.12 ± 1.20 | |
| SSIM ↑ | T1w → T2w | 75.94 ± 2.38 | 56.08 ± 4.82 | 83.33 ± 2.91 |
| T2w → T1w | 77.31 ± 1.67 | 51.93 ± 5.39 | 83.85 ± 2.15 | |
| LNCC ↑ | T1w → T2w | 13.12 ± 2.54 | 19.29 ± 2.52 | 21.56 ± 2.93 |
| T2w → T1w | 16.16 ± 2.44 | 19.15 ± 2.58 | 23.47 ± 2.75 | |
| FID ↓ | T1w → T2w | 36.74 | 49.55 | 55.74 |
| T2w → T1w | 70.04 | 72.03 | 53.56 |
We can see that PMSB achieves the best PSNR/SSIM/LNCC on both directions, while FID remains mixed. This supports generalization of PMSB under pathological anatomy. We acknowledge remaining limits (e.g., 2D slices, other anatomies) and will expand evaluation further in the future.
4. Computational cost
Each method was trained and tested on one GPU with 48 GB VRAM. We summarize the overall training time and per-slice inference time (including disk I/O etc) as follows.
| Metric | SynDiff | ContourDiff | UNSB | DSBM | LMSB | PMSB |
|---|---|---|---|---|---|---|
| Sampler | default | default | default | sde / ode | sde / ode | sde / ode |
| Train (h) | 55.8 | 33.0 | 75.7 | 39.5 | 47.8 | 56.0 |
| Infer (s/slice) | 0.24 | 1.42 | 3.15 | 4.95 / 12.87 | 4.90 / 12.51 | 4.89 / 12.41 |
We note that ContourDiff and UNSB need to be trained per translation direction and thus the effective training time needs to be doubled. Other methods work on both translation directions with one training.
5. Incremental contribution
We acknowledge that PMSB is a natural extension of LMSB by relaxing the shared mapping constraint. We argue this relaxation is practically important, because on large-gap T1w↔T2w translation, PMSB substantially outperforms LMSB as shown in Table 1 and Fig. 7.
Beyond the algorithmic change, the paper contributes a more fundamental pseudometric formulation with supporting theory, a stricter evaluation on paired ground-truth structural metrics, and a broader comparison with baseline methods than in the LMSB paper.
6. FID vs structural accuracy
We acknowledge the FID-structure trade-off for PMSB and we discuss it when presenting Table 1. We emphasize that anatomical fidelity is more important than FID for clinical MR translation. Moreover, PMSB’s overall FID is second-best behind only DSBM as shown in Table 1, while substantially outperforming DSBM on structural metrics.
Comments on the paper
1 comment
After rebuttal discussion
Dear reviewers,
The authors have responded to the reviews. Please check the rebuttal to see whether your concerns have been addressed, and raise any remaining questions to the authors if necessary. Please note that the final rating should be submitted before August 10.
Best
AC
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Thank you for your meta-review and for summarizing the reviewers' core concerns. We have carefully addressed the reviewers' concerns in our individual responses. Here is a brief summary of our new evidence and clarifications:
Incremental contribution (Reviewers it9j, JEyB): While the architectural change to independent mappings is straightforward, our primary contribution is the rigorous theoretical foundation justifying it. Unlike LMSB, which motivates the problem intuitively via differential geometry, PMSB formulates strict geometrical assumptions and derives the theory strictly from an optimal transport perspective, which goes significantly beyond prior work.
Experimental scope & robustness (Reviewers it9j, z3bP): We expanded our evaluation to the BraTS20 dataset, demonstrating PMSB's state-of-the-art generalizability to pathological, tumor-induced anatomy. Additionally, new ablation studies prove that PMSB remains highly robust without MNI pre-registration or when using artificially degraded segmentation targets.
Fairness of comparisons (Reviewer z3bP): We note that baselines like ContourDiff also use anatomical priors such as edge maps, and thus our comparisons are fair and effectively isolate the distinct benefits of optimal transport, anatomical guidance, and pseudometric framework.
Computational cost (Reviewers it9j, z3bP): We provided a detailed table of training and inference times.
Please refer to our individual reviewer responses for the complete quantitative tables and qualitative discussions. We hope these additions strengthen the paper and address the reviewers' comments.