potentialpaper

Fourier Contour Learning for Efficient and Traceable Cardiac MRI Quantification

Yi Yu, Zhenyu Bu, Ziyu Zhang, Yixuan Liu, Aotian Chen, James Mihalich, Parker Martin, Xia Ning, Yuchi Han, Yuan Xue

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

Abstract. Automated cardiac MRI quantification is commonly framed either as dense segmentation followed by voxel counting or as direct regression of global measurements. The two paradigms are difficult to unify: segmentation is visually interpretable but label-intensive and output-heavy, while regression is compact but less verifiable. We propose Fourier Contour Learning, which represents cardiac boundaries with compact anatomical Fourier contours. The predicted coefficients define smooth, interpretable contours and enable differentiable volume computation, connecting mask supervision, measurement supervision, and unlabeled-image regularization within one framework. We instantiate this representation with an anatomy-query decoder and cross-slice attention which creates a traceable path from image to contour to clinical measurement. Across three public datasets and an in-house all-phase cohort, our method achieves segmentation accuracy comparable to strong dense-prediction baselines, improves boundary agreement, and reduces clinically relevant volume error while using only a small number of output parameters per structure. We further show that the learned model provides an efficient interface for vision-language question answering and surface reconstruction. These results demonstrate the potential of Fourier contours as a unified intermediate representation for scalable, traceable, and clinically grounded cardiac analysis.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
2 May 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:44 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

The submission proposes a sparse Fourier representation for anatomical structures, which is then integrated in a DETR-style framework. The method achieves segmentation performance comparable to state-of-the-art segmentation models while providing smoother boundaries, improved surface reconstruction, and more accurate volume estimation. The method incorporates multiple supervision signals, and combines many aspects of anatomical structure analysis in an end-to-end framework, achieving results that are comparable with SOTA methods, though not necessarily surpassing them. VLM integration and surface reconstruction are interesting but not integrated with downstream clinical tasks. It would be more impactful to have explored the possibilities of VLM integration further, and performed a more extensive evaluation on downstream tasks.

Final justification

The authors were active in the rebuttal process, and the end result is a unanimous recommendation by reviewers that the submission passes the threshold for publication at NeurIPS. Additional downstream evaluation on functional reasoning and disease classification address the main point of improvement requested in the initial meta-review.

Area Chair KB1d · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

The submission proposes a sparse Fourier representation for anatomical structures, which is then integrated in a DETR-style framework. The method achieves segmentation performance comparable to state-of-the-art segmentation models while providing smoother boundaries, improved surface reconstruction, and more accurate volume estimation. The method incorporates multiple supervision signals, and combines many aspects of anatomical structure analysis in an end-to-end framework, achieving results that are comparable with SOTA methods, though not necessarily surpassing them. VLM integration and surface reconstruction are interesting but not integrated with downstream clinical tasks. It would be more impactful to have explored the possibilities of VLM integration further, and performed a more extensive evaluation on downstream tasks.

Final justification

The authors were active in the rebuttal process, and the end result is a unanimous recommendation by reviewers that the submission passes the threshold for publication at NeurIPS. Additional downstream evaluation on functional reasoning and disease classification address the main point of improvement requested in the initial meta-review.

Reviewer 7MLCOpenReview ↗
Rating
4/6
Confidence
3/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
use_inspired
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper proposes Fourier Contour Learning, a compact and traceable representation for cardiac MRI quantification. Instead of predicting dense segmentation masks or directly regressing clinical measurements, the method represents cardiac anatomical boundaries using a small set of Fourier contour coefficients. These coefficients can be decoded into smooth and visually inspectable contours, and the enclosed areas can be computed analytically to derive ventricular volumes.

Based on this representation, the authors develop a query-based contour prediction framework with anatomical queries for cardiac structures and cross-slice attention to incorporate volumetric context. The framework supports multiple forms of supervision, including mask-labeled data, measurement-labeled data, and unlabeled images through contour regularization losses such as edge alignment and scale consistency. Experiments on several public cardiac MRI datasets and an in-house cohort show that the proposed method achieves segmentation performance comparable to strong dense prediction baselines, improves boundary agreement and volume estimation, and provides compact anatomical tokens that can potentially support downstream applications such as vision-language question answering and surface reconstruction.

Strengths and weaknesses

Strengths

The paper is well motivated and addresses a practically important problem in cardiac MRI quantification. The authors identify a meaningful gap between dense segmentation, which is visually interpretable but annotation-intensive, and direct regression, which is compact but less traceable. The proposed Fourier contour representation is a reasonable intermediate form for this task, since cardiac structures such as LV and MYO are relatively smooth and can be represented compactly.

The method is technically coherent. Predicting Fourier coefficients allows the model to reconstruct anatomical contours and analytically compute enclosed areas for volume estimation. This design naturally connects mask supervision, measurement-level supervision, and unlabeled-image regularization. The experiments are reasonably complete, covering multiple CMR datasets and reporting not only Dice but also boundary agreement and volume error.

The paper is generally clear and easy to follow. The motivation, method overview, and qualitative visualizations are well presented. The ablation study also helps clarify the contribution of the main components.

Weaknesses

My main concern is the limited originality. Fourier descriptors and contour-based shape representations are established techniques, and the main contribution here is their adaptation to cardiac MRI quantification. While this adaptation is sensible and well engineered, I do not find it sufficiently novel as a general machine learning contribution.

The method is highly task-specific. Its advantages rely heavily on the relatively regular geometry of cardiac MRI structures, especially LV and MYO. The weaker performance on RV also suggests that the representation is less suitable for more complex anatomy. This limits the broader significance of the approach beyond this particular application.

The experimental comparison is not fully conclusive. The proposed method can exploit mask-labeled, volume-labeled, and unlabeled data, while the segmentation baselines are not given comparable weakly or semi-supervised training settings. Therefore, it is difficult to determine how much of the improvement comes from the Fourier contour representation itself versus the additional supervision sources.

The VLM and surface reconstruction results are interesting but feel more like auxiliary demonstrations than central contributions. In particular, the VLM experiment does not yet show substantial clinical reasoning beyond volume-related question answering.

Overall, I consider this a well-executed and clinically meaningful cardiac MRI paper, but the main contribution appears more suitable for a medical imaging venue than for NeurIPS.

Questions
  1. Could the authors provide a more controlled comparison under the same supervision setting? For example, comparing the proposed method with nnU-Net or another segmentation baseline using only the mask-labeled data would help clarify how much of the gain comes from the Fourier contour representation itself, rather than from additional volume-labeled or unlabeled data. My evaluation would increase if the authors can show that the proposed representation remains competitive under matched supervision.

  2. Could the authors better justify the novelty of the proposed representation compared with prior Fourier descriptor or contour-based segmentation methods? The current paper shows that Fourier contours are well adapted to cardiac MRI, but it is less clear what the methodological contribution is beyond this task-specific adaptation. A clearer discussion of the difference from existing contour/Fourier-based methods would help assess the originality of the work.

  3. Could the authors further analyze the failure cases, especially for RV? Since the method appears less suitable for complex and irregular structures, it would be helpful to show representative RV failure cases and discuss whether the limitation comes from the radial Fourier parameterization, the low truncation order, the choice of contour center, or the supervision design. This would help clarify the practical boundary of the proposed approach.

  4. Could the authors provide additional evidence for the benefit of volume-labeled and unlabeled data separately? An ablation that adds mask supervision, measurement supervision, edge alignment, and scale consistency step by step under the same training data split would make the empirical claims easier to interpret. This would help determine whether the weakly/self-supervised components are essential or only provide marginal improvements.

  5. The VLM experiment is interesting, but its current role is somewhat unclear. Could the authors clarify whether this is intended as a central contribution or only as a potential downstream application? If it is a central contribution, more meaningful evaluation beyond volume-related QA would be needed. Otherwise, I suggest presenting it more modestly as an exploratory demonstration.

Limitations

The authors have discussed several important limitations, including the weaker Dice performance compared with some dense segmentation models, the reduced suitability of the contour representation for complex RV geometry, and the difficulty of ensuring fully fair comparisons when different supervision types are used.

However, I think the limitation discussion could be further strengthened in two aspects. First, the authors should more explicitly discuss the limited generality of the proposed representation beyond cardiac MRI, since the method relies on relatively smooth and regular anatomical contours. Second, the potential clinical risks of over-smoothed contours should be discussed, especially in abnormal cases where local structural details may be clinically meaningful. A more detailed discussion of failure cases, domain shifts, and the conditions under which human verification is required would make the limitation section more complete.

Final justification

The rebuttal substantially strengthens the paper, especially through matched-supervision experiments and expanded VLM evaluation. I still have some reservations about whether Fourier contour learning constitutes a sufficiently general methodological contribution beyond this specific application, but the additional evidence addresses my main empirical concerns.

Formatting concerns

I did not notice any major formatting, anonymity, or policy concerns.

1 comment
Authors · RebuttalOpenReview ↗
Rebuttal

Thank you for your careful reading and thoughtful comments. We appreciate your recognition that the paper is well motivated, technically coherent, and clinically meaningful. We have added experiments under matched supervision, expanded the VLM evaluation to functional reasoning and diagnosis, and evaluated the same representation on abdominal MRI. We also clarify the methodological contribution relative to prior Fourier-based segmentation methods.

Q1. Methodological contribution beyond established Fourier descriptors

We agree that Fourier descriptors themselves are established, and we do not intend to claim otherwise. The contribution is the formulation of Fourier contours as a unified anatomical learning interface rather than only an alternative segmentation output.

Prior contour-based methods generally learn parametric boundaries from dense spatial annotations and evaluate them as segmentation models. In our framework, the same predicted coefficients also receive scalar measurement supervision because their enclosed area is available analytically. This connects a global clinical label to an explicit boundary without introducing a separate regression head.

The representation also enables unlabeled-image learning directly in contour space. Edge alignment uses image gradients to constrain the boundary, while scale consistency constrains how the coefficients should transform under geometric augmentation. These objectives act on the same anatomical representation learned from masks and measurements.

Finally, the anatomy-query features provide fixed-length tokens for downstream reasoning. The additional VLM experiment (Q4 below) shows that these tokens improve EF reasoning and disease classification while substantially reducing the visual-token burden.

The methodological contribution is therefore the differentiable anatomical bottleneck that connects mask supervision, clinical measurement supervision, unlabeled-image regularization, and downstream reasoning through one explicit representation. We will revise the introduction and related work to make this distinction clearer.

Q2. Performance under matched supervision and contribution of additional data

We performed the requested controlled experiment using identical ACDC splits, preprocessing, resolution, phase selection, and mask annotations.

Supervision LV Dice MYO Dice RV Dice LV Volume Error MYO Volume Error RV Volume Error
Mask only 92.93 87.38 85.97 6.01±4.75 7.97±7.09 8.59±10.26
Mask + measurement 92.95 87.04 85.57 5.64±4.78 7.22±6.23 8.03±7.86
Mask + unlabeled 93.12 88.74 87.59 5.98±4.96 7.60±6.92 8.25±8.26
Mask + measurement + unlabeled 93.01 88.36 87.70 5.56±4.33 6.90±6.52 7.77±7.24

With mask-only supervision, the differences from nnU-Net are 0.50 Dice points for LV and 1.00 point for MYO. The larger RV difference is consistent with the representation limitation discussed in Q3.

The added supervision does not simply produce a uniform improvement from more data and the effects are specific and interpretable. Measurement supervision reduces the mean volume error by 0.56 mL with almost no change in Dice. Unlabeled-image supervision improves mean Dice by 1.06 points. Their combination yields the best overall measurement accuracy.

Our proposed full setting is intended to test a capability that a mask-only pipeline does not naturally provide. A report-derived volume can supervise our contour coefficients because those coefficients analytically determine the measured volume. The same supervision cannot identify a unique dense mask without an additional weak-supervision mechanism. We will separate the mask-only and heterogeneous-supervision comparisons more clearly in the paper.

Q3. RV performance and the practical boundary of the representation

We agree that the radial assumption contributes to the RV gap. The RV is often crescent-shaped and locally concave, particularly at basal and apical levels. A single low-order radius function cannot reproduce every such configuration as accurately as a dense mask.

Fourier truncation contributes as well, but it is not the only factor. Increasing M from 4 to 6 improves RV NSD from 86.37% to 88.03%, while Dice changes little. At M=8, performance decreases. This indicates that higher frequencies recover some boundary detail, but increasing the number of coefficients alone does not fully address center sensitivity or non-star-convex geometry.

Despite lower overlap, the representation remains clinically useful for RV quantification. It reduces RV volume error relative to nnU-Net on all four evaluated cohorts: 8.20 to 7.86 mL on ACDC, 9.49 to 9.04 mL on M&Ms, 12.53 to 11.06 mL on M&Ms-2, and 9.67 to 7.85 mL on ACP. This is an important distinction because the goal is to preserve traceable anatomy and accurate measurement using a compact representation, rather than to optimize Dice alone.

We will add representative RV failure cases and discuss structure-specific orders, multiple local contours, and compact residual deformations as possible extensions.

Q4. Role of the VLM evaluation

The central contribution remains Fourier Contour Learning as a compact and traceable anatomical representation. VLM integration is a downstream validation of why such a representation is useful, rather than a claim that we introduce a general medical VLM.

We agree that the original volume-QA experiment was too narrow. We therefore added a task that uses ED and ES information for ejection-fraction reasoning and cardiac disease classification:

Input to Qwen3-VL LVEF Error RVEF Error Diagnostic Accuracy Time/Case Visual Tokens
Qwen3-VL fine-tuned on images 9.10 12.27 0.675 21.08 s 1,280
Ours + Qwen3-VL 6.70 9.08 0.850 10.41 s 60

This task requires the model to combine ED and ES anatomy, reason about ventricular function, and use that information for diagnosis. The contour-token model improves both LVEF and RVEF estimation and increases diagnostic accuracy by 17.5 percentage points. At the same time, it reduces the visual-token count by more than 20-fold and approximately halves inference time.

This result directly supports the downstream purpose of the representation. The Fourier model is not only producing another estimate of volume; its anatomy-query features provide an efficient interface for functional and diagnostic reasoning.

Q5. Generality beyond cardiac MRI

We evaluated the same method on an abdominal MRI dataset Abd-MR:

Method Liver Dice Left Kidney Dice Right Kidney Dice
nnU-Net 92.02 92.09 92.74
Ours 88.85 89.82 88.81

The results demonstrate that the method works beyond cardiac MRI. Without changing the representation, it achieves approximately 89% Dice for liver and kidney segmentation using only 11 coefficients for each contour.

nnU-Net remains more accurate in dense overlap, which is expected for these less regular boundaries. Fourier contours occupy a different point in the representation space. They retain an explicit boundary and substantially more geometric information than a bounding box, while being much smaller and more directly measurable than a dense mask.

The appropriate representation therefore depends on the downstream objective. Dense masks remain preferable when every local boundary detail is required. Fourier contours are attractive when measurement, output compactness, traceability, or efficient multimodal reasoning are also important. We will add the abdominal results and clarify that highly fragmented lesion or strongly non-star-convex structures may require a multi-contour or hybrid representation.

We also appreciate your concern regarding broader significance. While the experiments focus on a clinically important CMR application, the methodological contribution is beyond the cardiac-specific design. The same explicit representation connects dense anatomical supervision, scalar measurement supervision, unlabeled-image regularization, and compact downstream reasoning as demonstrated in Q4 above. The additional abdominal MRI results further show that the formulation transfers beyond cardiac anatomy without architectural modification.

Q6. Over-smoothing, abnormal anatomy, domain shift, and human verification

Fourier truncation can suppress small, high-frequency boundary details. We agree that this is a clinically relevant limitation when a focal contour irregularity is itself the target of diagnosis.

The evaluated CMR cohorts include DCM, HCM, abnormal RV anatomy, and other disease-related shape variation. Across these populations, the method remains competitive in Dice, improves boundary agreement for several structures, and consistently reduces volume error. The multi-center and multi-vendor M&Ms datasets also provide evidence under acquisition-domain variation.

Figure 5 further examines CMR scans with implantable cardioverter-defibrillator artifacts that were not included in training. The contour model preserves the principal cardiac boundaries more consistently than nnU-Net in these examples. We regard this as evidence of robustness to severe image artifacts.

Human verification remains important when the anatomy is highly irregular, when image artifacts obscure the true boundary, or when small focal morphology has direct clinical significance. We will make these conditions explicit in the limitation and broader-impact discussion.

Reviewer ZUN1OpenReview ↗
Rating
4/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper proposes Fourier Contour Learning for cardiac MRI quantification. Instead of predicting dense segmentation masks or directly regressing global cardiac measurements, the method predicts compact Fourier contour coefficients for cardiac anatomical structures. These coefficients can be decoded into smooth, visually inspectable contours and can also be used to compute ventricular areas and volumes analytically. The authors further instantiate this representation with an anatomy-query decoder, cross-slice attention, measurement supervision, and self-supervised contour regularization based on edge alignment and scale consistency.

Strengths and weaknesses

Strengths:

  1. Interesting intermediate representation. This work addresses the central challenge of connecting dense segmentation and direct measurement regression. The proposed Fourier contour representation is compact, visually traceable, and naturally linked to volume computation, which is appealing for cardiac MRI quantification.
  2. Learning from different annotations. The claims of the paper emphasize learning from mask-labeled, volume-labeled, and unlabeled data. This is a meaningful problem because dense annotations are expensive, while scalar measurements and unlabeled cine data are more abundant.

Weaknesses:

  1. The main advantage over strong segmentation baselines is not demonstrated. The paper argues that Fourier contours provide a better bridge between segmentation and regression, but the comparison is complicated by differences in training data and supervision. The proposed method uses mask-labeled data, volume-labeled data, and unlabeled data, while some competing segmentation baselines cannot directly use the same supervision. This makes it difficult to determine whether the gains come from the representation itself, the additional data, the measurement supervision, or the architecture.
  2. More controlled experiments are needed for different supervision. A central claim is that the method can leverage volume-labeled and unlabeled data, but the paper does not sufficiently quantify how much each data source contributes. For example, it would be useful to report performance under matched settings: mask-only, mask + volume, mask + unlabeled, mask + volume + unlabeled, and with varying amounts of labeled masks.
  3. The VLM and surface reconstruction claims are underexplored. The VLM experiment is interesting but preliminary. Table 2 only reports volume-difference-style results, and it is not clear whether the task demonstrates genuine language-based cardiac reasoning or only another route to volume estimation. Similarly, the surface reconstruction results are mostly qualitative. Quantitative surface metrics, reconstruction error, or comparison against ground-truth-derived surfaces would be needed to substantiate these claims.
  4. Fairness of comparisons needs clarification. Some baselines are taken from prior work, while others may be reimplemented or trained under different conditions. It is not always clear whether all methods use the same train/test splits, preprocessing, input resolution, phase selection, and amount of training data. Because the reported differences are sometimes modest, clearer experimental standardization is important.
Questions
  1. How much of the final performance gain comes from the Fourier contour representation itself versus the additional volume-labeled and unlabeled data?
  2. Can the authors provide a controlled comparison where nnU-Net or another dense segmentation baseline is trained with a matched amount of data, possibly using pseudo-labels or auxiliary volume supervision?
  3. Are there failure cases where the polar Fourier representation cannot represent RV or abnormal ventricular geometry well?
  4. How sensitive is the method to the choice of contour center? Since the contour is represented as a radial function, an inaccurate center may distort the contour representation.
Limitations

The authors discuss some important limitations, including lower Dice for some dense segmentation settings, reduced expressiveness for RV geometry, and difficulty in ensuring completely fair comparisons. However, I think several additional limitations should be addressed more explicitly.

First, the representation assumes that each structure can be reasonably described as a smooth radial contour from a reference center. This assumption is suitable for LV and MYO but less reliable for RV or abnormal anatomy. Second, the clinical evaluation should be expanded beyond volume difference to include EF and clinically relevant agreement analyses. Third, the VLM and surface reconstruction demonstrations should be framed as preliminary applications unless supported by stronger quantitative evidence.

Final justification

The rebuttal has addressed my concerns.

Formatting concerns

no

1 comment
Authors · RebuttalOpenReview ↗
Rebuttal

Thank you for your careful reading and constructive comments. We appreciate your recognition of Fourier contours as a compact and traceable intermediate representation. We have added controlled experiments to separate the effects of measurement and unlabeled supervision, and we have expanded the downstream evaluation to ventricular-function reasoning and disease classification.

Q1. Contribution of each supervision source and fairness of comparison

We agree that the original table alone did not fully separate these effects. We therefore trained four variants using identical ACDC splits, preprocessing, input resolution, phase selection, architecture, and mask annotations.

Supervision LV Dice MYO Dice RV Dice LV Volume Error MYO Volume Error RV Volume Error
Mask only 92.93 87.38 85.97 6.01±4.75 7.97±7.09 8.59±10.26
Mask + measurement 92.95 87.04 85.57 5.64±4.78 7.22±6.23 8.03±7.86
Mask + unlabeled 93.12 88.74 87.59 5.98±4.96 7.60±6.92 8.25±8.26
Mask + measurement + unlabeled 93.01 88.36 87.70 5.56±4.33 6.90±6.52 7.77±7.24

The mask-only result provides the requested matched-supervision evaluation. It remains close to nnU-Net for LV and MYO, while the RV gap reflects the geometric limitation discussed below.

The additional data sources play different roles. Measurement supervision reduces mean volume error by 0.56 mL with little change in mean Dice. Unlabeled-image regularization improves mean Dice by 1.06 points. The full model yields the lowest mean volume error, improving from 7.52 to 6.74 mL relative to mask-only training.

A dense segmentation model can in principle be modified with a global soft-volume loss. However, a scalar volume remains an underdetermined constraint on tens of thousands of pixel predictions. In our representation, volume is an analytic function of the same coefficients that define the explicit contour. Measurement supervision therefore acts directly on the anatomical state rather than through a separate global output.

We will revise Table 1 and the experimental description to distinguish results reproduced under common protocols from externally reported results and to make the role of each supervision source explicit.

Q2. RV failure cases and sensitivity to the contour center

We respectfully suggest that the radial center is not the primary cause of these failures. Although the contour is represented in polar coordinates, the reconstructed contour is directly supervised by the contour loss, which compares the predicted contour with the ground-truth contour rather than merely supervising the center itself. More importantly, the polar representation is valid as long as the selected center lies inside the contour. In our method, the RV is represented as the region between the BV and LVE contours, and we verified that, for all cases in our dataset, the selected center always lies within the corresponding contour. Therefore, center estimation is unlikely to be a limiting factor in our experiments. The fact that the LV and MYO use the same radial parameterization but do not exhibit similar performance degradation further supports this conclusion.

Based on the RV visualization in Fig. 5, the RV remains more challenging because its shape is less regular and contains local regions with abrupt changes in contour direction. These high-curvature structures are more difficult to approximate with a limited number of Fourier coefficients. Consistent with this observation, increasing the Fourier order M improves RV reconstruction quality. In the revised manuscript, we will highlight the error regions in the RV visualization of Fig. 5, with more failure cases in appendix, and add a corresponding discussion to better explain these failure cases.

Q3. Clinically meaningful downstream evaluation

We agree that the original volume-QA experiment did not fully demonstrate the downstream value of the anatomical tokens. We therefore added a downstream VLM integrated clinical task on the ACDC dataset that uses both ED and ES frames and requires ventricular-function reasoning and cardiac disease classification. Both methods use the same Qwen3-VL setup.

Input to Qwen3-VL LVEF Error RVEF Error Diagnostic Accuracy Time/Case Visual Tokens
Qwen3-VL fine-tuned on images 9.10 12.27 0.675 21.08 s 1,280
Ours + Qwen3-VL 6.70 9.08 0.850 10.41 s 60

This task requires the model to combine ED and ES anatomy, reason about ventricular function, and use that information for diagnosis. The contour-token model improves both LVEF and RVEF estimation and increases diagnostic accuracy by 17.5 percentage points. At the same time, it reduces the visual-token count by more than 20-fold and approximately halves inference time.

The output for the first test patient from our VLM model is presented below:

A: LVEDV=231 mL, LVESV=155 mL. LVEDVI=LVEDV/BSA=231/1.93=120 mL/m^2. LVEF=(231-155)/231=33%. DCM check: LVEDVI>100 mL/m^2 is yes, LVEF<40% is yes. MYOEDV=124 mL, MYOESV=122 mL. MYOEDVI=MYOEDV/BSA=124/1.93=64 mL/m^2. HCM check: MYOEDVI>105 mL/m^2 is no, LVEF>55% is no. RVEDV=127 mL, RVESV=63 mL. RVEDVI=RVEDV/BSA=127/1.93=66 mL/m^2. RVEF=(127-63)/127=50%. RV check: RVEDVI>110 mL/m^2 is no, RVEF<40% is no. Final diagnosis: DCM.

This result directly supports the downstream purpose of the representation. The Fourier-based model does not merely produce another volume estimate; its anatomy-query features provide an efficient interface for functional and diagnostic reasoning.

The surface-reconstruction result addresses a different capability. Because corresponding contour points are ordered, the model can construct a mesh directly without first rasterizing a mask and applying marching cubes. We will clarify this as a direct geometric property of the representation and avoid presenting it as a benchmarked surface-reconstruction method without a dedicated quantitative comparison.

Reviewer X56uOpenReview ↗
Rating
4/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
4/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper proposes a Fourier Contour Learning framework for cardiac MRI quantification that represents anatomical structures using compact Fourier contour coefficients instead of dense segmentation masks. The proposed DETR-style framework predicts analytic contours, enabling unified learning from mask labels, volume measurements, and unlabeled data through multiple supervision signals. The method achieves segmentation performance comparable to state-of-the-art segmentation models while providing smoother boundaries, improved surface reconstruction, and more accurate volume estimation. In addition, the learned contour tokens can be directly integrated with vision-language models for downstream quantitative reasoning tasks. Extensive experiments on multiple cardiac MRI datasets demonstrate the effectiveness and generalization capability of the proposed representation.

Strengths and weaknesses

Strengths

  • The paper introduces a compact Fourier contour representation that effectively bridges dense segmentation and direct measurement regression, providing a new perspective for cardiac image analysis.
  • The proposed model combines contour regression, differentiable volume estimation, cross-slice attention, and multiple complementary loss functions into a coherent end-to-end framework.
  • Results are evaluated on multiple public datasets with comprehensive ablation studies, external validation, robustness analysis, surface reconstruction, and VLM integration.
  • Unlike conventional segmentation methods, the proposed representation naturally supports accurate volume estimation, smooth 3D surface reconstruction, and compact anatomical tokens for future medical VLM applications.

Weaknesses

  • Dice scores are generally comparable to existing segmentation methods rather than significantly better, especially for the right ventricle (RV), where several baselines still outperform the proposed method.
  • The Fourier representation is mainly suitable for relatively smooth anatomical structures and may not generalize well to organs or lesions with highly irregular boundaries. The authors also acknowledge this limitation.
  • The VLM integration and surface reconstruction are interesting demonstrations but remain preliminary and are not extensively validated with downstream clinical tasks.
  • The proposed framework benefits from multiple supervision sources (mask, measurement, and unlabeled data), whereas competing segmentation methods cannot directly utilize the same supervision, making completely fair comparison difficult.
Questions
  • Why was Fourier contour representation selected over alternative parametric shape representations such as splines, implicit neural representations, or signed distance functions?
  • The proposed method is primarily evaluated on cardiac MRI. How well would the framework generalize to anatomies with substantially more irregular boundaries (e.g., tumors, liver, pancreas)?
  • The VLM experiment focuses only on volume estimation. Can the proposed anatomical tokens support more complex clinical reasoning tasks such as diagnosis, disease grading, or report generation?
  • Since RV performance remains consistently lower than LV and MYO, are there architectural modifications that could better capture highly complex anatomical structures?
  • How sensitive is the method to inaccurate contour annotations or inter-observer variability in manual delineations?
  • Could the contour representation be naturally extended to full 3D or 4D continuous representations instead of predicting slice-wise contours?
  • What is the computational overhead compared with nnU-Net during both training and inference?
Limitations

yes

Final justification

The rebuttal has addressed most of my concerns, and the revisions are consistent with the feedback from the other reviewers. Therefore, I lean toward a borderline accept.

Formatting concerns

N/A

1 comment
Authors · RebuttalOpenReview ↗
Rebuttal

Thank you for your careful reading and constructive comments. We appreciate your recognition of the compact representation, multi-source supervision, and downstream potential of our method. We have provided additional clarification and supporting experiments on matched supervision, broader anatomical applicability, computational efficiency, and VLM-based functional reasoning and diagnosis. Detailed responses to your questions are provided below.

Q1. Motivation for choosing Fourier contours over other parametric representations

We selected Fourier contours because they provide a particularly useful combination of compactness, traceability, and analytic measurement for CMR quantification. A fixed number of coefficients defines an ordered anatomical boundary that can be directly visualized. More importantly, the enclosed area has a simple closed-form expression in terms of the same coefficients. This allows ventricular measurements from clinical reports to supervise the anatomical representation directly.

Signed distance functions and implicit representations offer greater geometric flexibility, but recovering their boundaries and measurements generally requires dense spatial evaluation. Splines are also compact and interpretable, but their behavior depends on the number and placement of control points or knots. Fourier coefficients instead provide a frequency-ordered representation: lower-order terms describe global shape, while higher-order terms progressively recover local variation. This also gives a direct control over the accuracy–compactness trade-off through M.

We do not claim that Fourier contours are universally preferable to these alternatives. They are particularly well matched to our objective of connecting a compact and visually inspectable boundary with differentiable clinical measurement. We will include this clarification in the revised paper.

Q2. Applicability beyond relatively smooth cardiac anatomy

We agree that the original submission primarily evaluated cardiac anatomy. CMR quantification is itself an important and technically demanding problem, but the proposed representation is not specific to cardiac structures. To examine its broader applicability, we applied the same method to an abdominal MRI dataset, Abd-MR[1], and obtained the following results:

Method Liver Dice Left Kidney Dice Right Kidney Dice
nnU-Net 92.02 92.09 92.74
Ours 88.85 89.82 88.81

These results show that our Fourier Contour Learning is not restricted to cardiac structures. The same formulation achieves approximately 89% Dice for the liver and kidneys without changing the representation. Each contour is described by only 11 coefficients at M=4, rather than a dense spatial output.

The comparison also illustrates the intended trade-off. nnU-Net retains an advantage when the primary goal is the most detailed pixel-level boundary. Our representation gives up some local flexibility in exchange for a substantially smaller output that remains anatomically explicit and can be supervised directly by measurements. This compact representation is particularly useful when quantification or downstream token efficiency matters in addition to Dice. Please refer to answers to Q8 later.

The Fourier order controls part of this trade-off. Higher M can represent more irregular boundaries, although strongly non-star-convex or fragmented structures may require multiple local contours or a hybrid representation. We will add the abdominal downstream results and clarify this practical scope in the revision.

[1] A Emre Kavur, N Sinem Gezer, et al. CHAOS challenge-combined (CT-MR) healthy abdominal organ segmentation. Medical Image Analysis, 2021.

Q3. Interpretation of comparisons under different supervision sources

We agree that the original results did not fully separate performance under matched mask supervision from the additional benefit of measurement-labeled and unlabeled data. We therefore performed a controlled study on ACDC. All settings use the same train/test split, preprocessing, image resolution, phase selection, and mask annotations.

Supervision LV Dice MYO Dice RV Dice LV Volume Error MYO Volume Error RV Volume Error
Mask only 92.93 87.38 85.97 6.01±4.75 7.97±7.09 8.59±10.26
Mask + measurement 92.95 87.04 85.57 5.64±4.78 7.22±6.23 8.03±7.86
Mask + unlabeled 93.12 88.74 87.59 5.98±4.96 7.60±6.92 8.25±8.26
Mask + measurement + unlabeled 93.01 88.36 87.70 5.56±4.33 6.90±6.52 7.77±7.24

The mask-only model remains close to nnU-Net for LV and MYO under matched spatial supervision, with differences of 0.50 and 1.00 Dice points, respectively. RV remains more difficult, which we discuss separately below.

The new experiment also separates the roles of the additional supervision. Measurement labels reduce the mean volume error from 7.52 to 6.96 mL while leaving mean Dice nearly unchanged. Unlabeled-image regularization improves mean Dice by 1.06 points. Combining both produces the lowest mean volume error of 6.74 mL while retaining most of the contour-accuracy gain.

This ability to use report-derived measurements is the unique advantage of our proposed representation. A scalar ventricular volume does not define a unique dense mask. A conventional segmentation model therefore requires an additional weakly supervised formulation, pseudo-labels, or a separate regression head to use such data. In our framework, the same Fourier coefficients determine both the visible contour and its enclosed volume. The clinical measurement can therefore supervise the anatomical representation directly, without introducing a separate output whose anatomical correspondence is uncertain.

We will distinguish the matched mask-only comparison from the full heterogeneous-supervision setting more clearly in the revised manuscript.

Q4. Lower RV Dice and possible architectural improvements

We agree that RV is more challenging because of its crescent shape, local concavities, and greater variation across basal and apical slices. These properties are less well captured by one low-order radial contour than the more regular LV and myocardial boundaries.

Increasing the Fourier order helps boundary agreement. In Table 3, changing M from 4 to 6 increases RV NSD from 86.37% to 88.03%, although the Dice gain is small. Increasing M further to 8 reduces performance, suggesting that simply adding coefficients makes optimization harder without fully resolving the geometric limitation.

Importantly, the lower RV Dice does not translate into poorer clinical quantification. Compared with nnU-Net, our ConvNeXt model reduces RV volume error from 8.20 to 7.86 mL on ACDC, from 9.49 to 9.04 mL on M&Ms, from 12.53 to 11.06 mL on M&Ms-2, and from 9.67 to 7.85 mL on ACP. This distinction reflects the objective of our representation: we seek an efficient and traceable anatomical state that supports reliable measurement, rather than optimizing overlap alone.

Structure-specific Fourier orders, multiple local contours, or a compact residual-deformation branch could better capture highly concave RV geometry. We will add representative RV cases and discuss these possible extensions.

Q5. Sensitivity to annotation quality and inter-observer variability

Low-order Fourier truncation naturally suppresses small pixel-level irregularities in manual contours. The edge-alignment objective provides an additional image-based constraint by encouraging the predicted contour to follow visible intensity transitions rather than relying only on the supplied mask.

During development, we performed a controlled experiment in which training masks were eroded by one pixel. For the case illustrated in Fig. 4, adding edge alignment improved contour IoU from 85.32% to 91.29%. This example shows how image evidence can partially correct a systematically shifted annotation.

We agree that one controlled case is not a substitute for a full inter-observer study. We will describe this result as supporting evidence for the mechanism and identify multi-reader evaluation as an important future direction.

Q6. Extension to continuous 3D or 4D anatomy

Although contours are predicted per slice, the model is not an independent 2D predictor. Cross-slice attention exchanges information across the complete stack before contour prediction. The resulting contours also provide ordered point correspondences across slices, allowing them to be connected directly into a lofted 3D surface, as shown in Appendix D and the supplementary 4D cine visualization.

A 3D or 4D extension could model the Fourier coefficients as continuous functions of slice position and cardiac phase. For anatomies that can be described by a global radial surface, spherical harmonics offer another possible extension. Structures with more complex topology would likely benefit from multiple local surface charts rather than one global harmonic representation.

We will clarify the distinction between our current cross-slice model, its direct 3D surface reconstruction capability, and these future continuous extensions.

Q7. Computational efficiency relative to nnU-Net

We evaluated both methods on the same 10\times256\times256 input under the same inference environment:

Method Parameters FLOPs Inference time/case
nnU-Net 44.3M 400.3G 189.5 ms
Ours (ResNet) 42.1M 137.4G 23.2 ms

Our model uses approximately 1/3 of the FLOPs and is 8.2x faster in this evaluation. It also produces only 11 coefficients for each structure and slice instead of a dense 256\times256 output. We will report the inference protocol and distinguish computational efficiency from representation efficiency in the revision.

Q8. VLM-based functional reasoning and diagnosis

Please refer to response to Reviewer ZUN1 Q3 below.

Comments on the paper

1 comment
Authors · CommentOpenReview ↗

Dear AC and Reviewers,

Thank you for your constructive feedback and for recognizing the motivation, technical coherence, and potential value of our work. We have posted detailed point-by-point responses to all reviewer questions and added several new analyses and experiments.

In particular, the AC highlighted the need for a stronger evaluation of downstream VLM applications. We address this point with a new functional reasoning and disease-classification experiment for clinical VLM integration. Our contour-token interface improves LVEF and RVEF reasoning and diagnostic accuracy, while reducing the number of visual tokens from 1,280 to 60 and approximately halving inference time.

We also provide the following additional evidence:

  • A matched-supervision study that separates the effects of mask labels, report-derived measurement labels, and unlabeled images. The results show that analytic volume computation allows report measurements to directly supervise the same contour representation, improving volume accuracy, while image–contour consistency learning from unlabeled data improves contour accuracy.
  • A same-input computational comparison showing that our model uses approximately one-third of the FLOPs and is 8.2× faster than nnU-Net at inference.
  • An additional abdominal MRI experiment demonstrating the applicability of our vision encoder beyond cardiac anatomy, offering a new tradeoff between accuracy and efficiency.

We hope these new results and clarifications address the main concerns raised in your reviews. We would be glad to provide further clarification if any questions remain!

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Missing a submission?

Loading the discussion…